Professional Documents
Culture Documents
7.02124.24.00
SIGNUM
Installation and
operating instructions
H 250/M9
Variable area flowmeters
Cat. II2G
Cat. II3GD
Table of Contents
Product liability and warranty .....................................................................................................4
Scope of delivery..........................................................................................................................4
1 General.................................................................................................................................... 5
1.1
Designation code..................................................................................................................5
1.2
Marking.................................................................................................................................6
1.3
Key to Pressure Equipment Directive ...................................................................................7
1.4
Functional principle...............................................................................................................8
2 Installation and Start-up ........................................................................................................ 8
2.1
Prerequisite for the installation .............................................................................................8
2.2
Preparation of the pipeline....................................................................................................8
2.3
Installation in the pipeline .....................................................................................................9
2.4
Magnetic filters .....................................................................................................................9
2.5
Tightening torques................................................................................................................9
2.6
Conformity with IP degree of protection..............................................................................10
2.7
Start-up...............................................................................................................................10
2.8
Measurement of liquids ......................................................................................................10
2.9
Measurement of gases .......................................................................................................10
2.10 Float damping.....................................................................................................................11
3 Flow tables ........................................................................................................................... 11
3.1
H 250/RR, H 250/HC (Hastelloy C4) .................................................................................12
3.2
H 250/C ceramics ...............................................................................................................13
4
Materials ............................................................................................................................... 14
6 Medium temperatures.......................................................................................................... 16
6.1
Maximum temperature of medium TS ................................................................................16
6.2
M9 with built-in electrical components ................................................................................16
7 Dimensions and weights ..................................................................................................... 17
7.1
H 250/RR, H 250/Hastelloy C4 ...........................................................................................17
7.2
H250 with screw connection, H250 /F ................................................................................18
7.3
Weights H250/C (ceramics / PFTE)....................................................................................18
8 Indicator M9.......................................................................................................................... 19
8.1
Eddy-current brake .............................................................................................................19
8.2
Limit switches .....................................................................................................................19
8.2.1 Electrical connection...........................................................................................................20
8.2.2 Limit setting ........................................................................................................................22
8.2.3 Switch contact definition .....................................................................................................22
8.2.4 Technical data of limit switches ..........................................................................................24
8.3
Electrical signal output ESK II ............................................................................................24
8.3.1 Electrical connection...........................................................................................................24
8.3.2 HARTTM communication with the ESK II.............................................................................25
8.3.3 Technical data of ESK II .....................................................................................................26
8.4
Electrical signal output ESK3-PA Profibus .........................................................................26
8.4.1 Bus cable............................................................................................................................26
8.4.2 Shielding and grounding.....................................................................................................26
2
8.4.3
8.4.4
8.5
8.5.1
8.5.2
8.5.3
8.6
8.6.1
9 Service .................................................................................................................................. 31
9.1
Replacing the float ..............................................................................................................31
9.2
Retrofitting of float damping................................................................................................32
Installation of the eddy-current brake .................................................................................32
9.3
9.4
Contact module ..................................................................................................................33
Electrical signal output ESK II.............................................................................................33
9.5
9.5.1 Installing an ESK II .............................................................................................................33
9.5.2 Replacing an ESK II............................................................................................................34
9.5.3 Setting the zero point and 100% value at the ESK II ..........................................................34
9.5.4 Retrofitting an ESK II and calibrating it ...............................................................................35
9.5.5 Changing the measuring range and conversion, ESK II .....................................................35
Flow counter / totalizer ESK-Z ............................................................................................36
9.6
9.7
High-temperature design ....................................................................................................36
10 Spare part list ....................................................................................................................... 38
11 Maintenance ......................................................................................................................... 40
Returning a device for testing or repair to KROHNE...............................................................43
Scope of delivery
The scope of delivery of the variable area flowmeter in the version ordered includes:
Installation and operating instructions Ident. No.: 702124##00
For devices of explosion-protected design, please use the
supplementary installation and operating instructions:
General
1.1
Designation code
H 2 5 0 /
1
/
2
/
3
/
4
/
6
/
7
High-temperature design
HT
:
Design with HT extension
Limit switch
K1
:
One limit switch
K2
:
Two limit switches
Explosion protection
EEx
:
Explosion-protected equipment to European Standard
1.2
Marking
The type designation of the complete device is given on the indicator part by means of the
nameplate reproduced here (also refer to the designation code).
Example:
MD:
PS:
PT max:
TS:
PED:
Tag-No:
0044:
Year of manufacture
Max. permissible operating pressure at max. operating temperature
Maximum pressure tested
Max. operating temperature
Pressure Equipment Directive
Measuring point tag
Identification number of the controlling agency for EC Pressure Equipment Directive
97/23/EC
Additional marking:
SN:
Serial number
SO:
Sales order / item
KO:
KROHNE order
Vxxx:
Product configurator code
AC:
Article code
1.3
PED
1
/
2
Fluid
G
L
3
/
4
Gases, liquefied gases, gases dissolved under pressure, vapour and those
liquids whose vapour pressure lies more than 0.5 bar above the normal
atmospheric pressure (1013 mbar) at the maximum permissible temperature
Liquids whose vapour pressure lies a maximum of 0.5 bar above atmospheric
pressure at the maximum permissible temperature
Fluid group 1:
Fluid group 2:
Category
3.3
In accordance with Article 3.3 of Directive 97/23/EC
I
Category I to 97/23/EC
II
Category II to 97/23/EC
III
Category III to 97/23/EC
1.4
Functional principle
2.1
The operating pressure of the plant may not exceed the value indicated on the rating plate.
Ensure that the parts coming into contact with the medium are compatible with the material.
The ambient and medium temperatures may not exceed certain maximum values.
The variable area flowmeter has to be installed vertically (float measuring principle flow direction
from bottom to top).
In order to prevent distortions the connecting flanges have to face each other axially and in
parallel.
2.2
The pipeline is to be supported by suitable installation measures so that vibrations at the pipeline
are prevented and axial stresses on the instrument are minimized.
A straight unimpeded inlet run of 5 x DN before the instrument and a straight outlet run of
3 x DN behind the instrument are recommended.
Shutoff and control devices are to be positioned in the flow direction behind the measuring device.
For installation recommendations, please also refer to guideline VDE/VDI 3513, Sheet 3.
2.3
The instrument may not be subjected to tensile or compressive stresses through the pipelines.
Immediately before installing, check that the device is free of foreign particles.
Screws, bolts and gaskets (provided by customer) to be selected in accordance with the pressure
stage of the connecting flange or the operating pressure.
The inside diameter of the flange deviates from the standard dimensions. Flange seal standard
DIN 2690 can be applied without any limitation.
Align the gaskets. Tighten the nuts with the tightening torques of the appropriate pressure stage.
2.4
Magnetic filters
Magnetic filters are used when the medium contains particles which can be influenced
magnetically. The magnetic filter is to be installed in the flow direction before the flowmeter.
Magnetic bars are positioned helically in the filter to provide optimum efficiency at low pressure
loss. All the magnets are coated individually with PTFE to protect against corrosion.
Two models are available:
Type F
Fitting part with flange
Overall length 100 mm
Type FS
Fitting part without flange
Overall length 50 mm
2.5
Tightening torques
PTFE liner or
ceramic liner and PTFE sealing face
tighten the flange bolts with the following max. torques:
Nominal size to
Bolts
Max. tightening torque
EN 1092-1 ASME B 16.5 EN 1092-1
ASME B 16.5
EN 1092-1 ASME B 16.5 150 lbs
DN PN Inch
lbs
150 lbs 300 lbs Nm ftlbf
Nm
ftlbf
15
40
150/300 4 x M 12
4 x
4 x
9.8
7.1
5.2
3.8
25
40
1
150/300 4 x M 12
4 x 4 x 5/8
21
15
10
7.2
50
40
2
150/300 4 x M 16
4 x 5 /8 8 x 5 /8
57
41
41
30
80
16
3
150/300 8 x M 16
4 x 5/8 8 x
47
34
70
51
100
16
4
150/300 8 x M 16
8 x 5/8 8 x
67
48
50
36
2.6
The following instructions should be followed in order to observe the IP degree of protection of
built-in electrical parts.
After the connecting cable has been introduced, tighten the outlet nut.
All cable glands not used remain closed with blanking plugs.
Do not kink lines directly at the cable gland.
Provide a drain bend
The incoming lines may not be subjected to mechanical strain. Refer to the description of the
electrical supplementary components for this device.
Cable glands / screwed glands:
Thread
M 16x1.5
M 20x1.5
M 16x1.5
M 20x1.5
Material
PA
PA
Nickel-plated brass
Nickel-plated brass
Cable diameter
5 - 10 mm
8 - 13 mm
5 - 9 mm
10 - 14 mm
Degree of protection*
IP 68 - 5 bar
IP 68 - 5 bar
IP 68 - 5 bar
IP 68 - 10 bar
Remark
Standard
2.7
Start-up
2.8
Measurement of liquids
2.9
Measurement of gases
10
Generally when CIV and DIV floats are used for gas measurement
For TIV floats (only for H250/RR and H250/HC) with an operating pressure (inlet pressure):
Nominal size to
EN 1092-1 ASME B 16.5
DN mm
Inch
15
25
1
50
2
80
3
100
4
Flow tables
General
Reference conditions:
Water
Air
at 20C
at 20C; 1.013 bar abs.
Conversion to other media or operating data (pressure, temperature, density, viscosity) is carried
out by means of the KROHNE calculation method KroVaCal on the basis of the
VDE / VDI Guideline 3513.
The specified flow values are 100% values of the measuring range.
The turn-down ratio is 10 : 1
The specified pressure losses apply to water and air at maximum flow rate.
11
3.1
Float material
Float shape
Nominal size
EN 1092-1 ASME
B 16.5
DN
Inch
15
"
25
1"
50
2"
80
3"
100
4"
Cone
No.
K 15.1
K 15.2
K 15.3
K 15.4
K 15.5
K 15.6
K 15.7
K 15.8
K 25.1
K 25.2
K 25.3
K 25.4
K 25.5
K 55.1
K 55.2
K 55.3
K 85.1
K 85.2
K105.1
Water
l/h
CIV
25
40
63
100
160
250
400
630
630
1000
1600
2500
4000
6300
10000
16000
25000
40000
63000
Air
m/h
DIV
1000
6300
25000
100000
TIV *
0.7
1.0
1.5
2.2
3.6
5.5
10
14
14
22
35
50
80
80
110
150
350
400
18
28
110
170
230
350
600
*
Not for instruments with heating
* * 300 mbar with damping (gas measurement)
The specified pressure losses apply to water and air at maximum flow rate.
12
CIV
26
26
26
26
26
26
28
32
32
33
34
38
45
74
77
84
68
89
120
TIV
21
21
21
21
21
21
21
22
24
24
25
26
30
13
13
13
16
16
DIV
**
**
**
**
**
**
38**
50**
**
**
**
78**
103**
60**
69**
104**
**
**
220**
3.2
H 250/C ceramics
Float material
Float shape
Nominal size
EN
ASME
B 16.5
DN
Inch
15
25
50
80
100
PTFE, ceramics
Type E
Float
Number
E 17.2
E 17.3
E 17.4
E 17.5
E 17.6
E 17.7
E 17.8
E 27.1
E 27.2
E 27.3
E 27.4
E 27.5
E 57.1
E 57.2
E 57.3
E 87.1
E 87.2
E 107.1
630
500
1000
700
1600
1100
2500
1600
2500
4000
4500
6300
6300
10000
11000
16000
16000
25000
25000
40000
Air
Ceramics
m/h
1.8
2.4
4.0
6.5
9.0
18
22
30
50
75
140
200
350
70
55
55
80
60
66
108
70
70
158
82
82
100
100
81
70
70
110
80
80
170
110
110
81
70
95
85
100
Ring orifice
Diameter
mm
12
25.6
46.4
72
84
13
Materials
1)
Design
H 250
H 250 / RR
H 250 / HC
H 250 / C
H 250 / F
2)
Materials
Measuring tube
CrNi steel
1.4404 *
Hastelloy C4
(2.4610)
CrNi steel 1.4571
with liner
made of PTFE **
CrNi steel 1.4435
Flange /
sealing face
CrNi steel
1.4404 * solid
CrNi steel 1.4571 *
coated with
Hastelloy C4
(2.4610)
CrNi steel 1.4571
with liner
made of PTFE **
CrNi steel 1.4435
Float
CrNi steel
1.4404*
Hastelloy C4
(2.4610)
HC4, PTFE or
Al2O3 with gasket:
Kalrez KLR 6375***
CrNi steel 1.4435
Liquids
Gases
Oxygen
Hastelloy
Ceramics or Hastelloy
PEEK
O-ring
14
Interceptor /
Guide
CrNi steel
1.4404*
Hastelloy C4
(2.4610)
Ring
orifice
Al2O3 or PTFE
Al2O3
Connection dimensions to
Connection dimensions to
1.6
2.5
EN-1092-1
ASME B 16.5
JIS B 2238
DlN 32676
ISO 2852
Screw connections
(H 250 /RR /HC /F)
Connection dimensions to
DIN 11851
Connection dimensions to
Connection dimensions to
SMS1146
ISO 228
ASME B1.20.1
ISO 228
Connection dimensions to
ASME B 1.20.1
DIN 11864 - 1
Connection dimensions to
Flange connection
DIN 11864 - 2
EN 1092-1
ASME B 16.5
DN15-100,
1/2" - 4",
LR 15-100
DN15 - 100,
10-16 bars
Size 25-139.7
10-16 bars
DN15 - 100,
25 - 40 bars
1"- 4", 6 bars
G3/4" -, G1" PN 50
3/4" NPT
G1/2" - 1",
PN 40 50
1/2" - 1" NPT
DN 15 - 50 : PN 40
PN16-100
150 - 600 lbs
10K-20K
DN 15 - 50 : PN 40
DN 15; PN 40
1/2"; 150 lbs / RF
E12, PN 40
DN 80 - 100 : PN 16
DN 80 - 100 : PN 16
Measuring tube
250/RR
H250/HC (Hastelloy C4)
H 250/C (ceramics / PTFE)
Float shapes
H250/RR,
H250/HC (Hastelloy C4)
Liquids
Gases
Liquids,
Gases
conical, Type E
Overall height
With flange connection (without gaskets)
With special connections
Operating pressure PS
(Pressure Specified)
250 mm
300 mm (H 250/RR)
Directive 97/23/ EC of the Council of April 29, 1999 on mobile pressurized equipment
(Pressure Equipment Directive) is applied. The maximum permissible operating pressure PS is
calculated for the maximum operating temperature TS. Both limits (PS and TS) are listed on the
rating plate. As a rule, PS corresponds to the nominal pressure of the connection.
Pressure Tested PT
The pressure tested is calculated in accordance with the Pressure Equipment Directive (97/23/EC) or AD 2000-HP30 under
consideration of the maximum permissible operating pressure as well as the maximum operating temperature.
Degree of protection of the display M9 in accordance
with EN 60529 / IEC 60529
IP 67, NEMA 4X
15
Medium temperatures
6.1
Design
Material
H250 / RR
H250 / HC
Stainless steel
Hastelloy C4
H250 / C
H250 / C
H250 / C
Float
PTFE
Ceramics
Ceramics
Max. temperature
of medium
TS [C]
300
300
At ambient
temperature
Tamb. [C]
120
120
70
150
250
70
70
120
Liner
PTFE
PTFE
TFM
TS
- 80C
Tamb. - 40C to + 90C (Standard version)
- 20C to + 90C (screw fitting)
6.2
Without heating
jacket
EN
ASME
B 16.5
DN 15
", 1"
DN 25
With heating
jacket
EN
ASME
B 16.5
DN 15 "
DN 50
2"
DN 25
1"
DN 80
DN 100
3"
4"
DN 50
DN 80
2"
3"
Tamb. <40C
Design with
ESK II, ESK-S, ESK3-PA
ESK II with totalizer
Limit switch SC.. SJ..
Limit switch SB..
ESK II, ESK-S, ESK3-PA
ESK II with totalizer
Limit switch SC.. SJ..
Limit switch SB..
ESK II, ESK-S, ESK3-PA
ESK II with totalizer
Limit switch SC.. SJ..
Limit switch SB..
TS C
Standard
200
200
200
200
200
180
200
200
200
150
200
190
Abbreviations:
HT
ESK II
ESK-S
ESK3-PA
SC
SJ
SB
16
High-temperature version
current transmitter in 2-wire technology 4 20 mA
current transmitter in 3-wire technology 0 20 mA
PROFIBUS transmitter
limit switch type NAMUR
limit switch type NAMUR safety-oriented
limit switch type 3-wire, open collector
TS C (1)
Standard
180
80
200
130
165
75
200
120
150
70
200
110
HT
300
130
300
295
300
100
300
195
250
85
300
160
TS C (2)
Standard
150
80
150
130
125
75
125
120
105
70
105
105
HT
235
130
235
235
170
100
170
170
145
85
145
145
7.1
H 250/RR, H 250/Hastelloy C4
PN40
PN16
PN40
150lbs/RF
DN15, DN25
", 1"
Standard version
Nominal sizes
DN
15
25
50
80
100
Dimensions in mm
PN
40
40
40
16
16
70.5
70.5
57.5
57.5
57.5
194
194
181
181
181
107
119
132
148
158
Heating
100
106
120
160
150
187
199
212
228
232
d
20
32
65
89
114
Approx.
weight
with DIN
flanges
kg
3.5
5.0
8.2
12.2
14.0
Approx.
weight
with heating *
kg
4.8
6.7
10.4
14.0
16.6
High-temperature *
150
138
250
123,5
* The high-temperature (HT) version is to be preferred when the measuring tube is insulated
17
H 250 / F
Food version with
clamp connection
300
H 250 / F
screw connection
DIN 11851
250
300
Iso 228
Female thread,
screwed
250
7.2
25
1
50
2
80
3
100
4
7.3
Operating pressure
bar
psig
40
580
40
580
25
363
25
363
25
363
Approx. weight in
kg
lbs
2.0
4.4
3.5
7.7
5.0
11.0
7.6
16.8
10.3
22.7
DN
15
25
50
80
100*
PN
40
40
40
16
16
Inch
1
2
3
4
lbs
150/300
150/300
150/300
150/300
150/300
EN 1092-1
kg
3.5
5
10
13
15
lbs
7.7
11.0
22.1
28.7
33.1
Approx. weights
ASME B 16.5
150 lbs
300 lbs
kg
lbs
kg
lbs
3.2
7.0
3.5
7.7
5.2
11.5
6.8
15.0
10
22.1
11
24.3
13
28.7
15
33.0
16
35.3
17
37.5
* only PTFE
Overall height from 3" / 300 lbs : 300 mm
Dimensions: see standard design
18
Indicator M9
8.1
Eddy-current brake
Magnets
Pointer vane
Retainer
Pointer cylinder
8.2
Limit switches
Contact types:
SC3,5-N0-Y
SJ3,5-SN
SJ3,5-S1N
SB 3.5-E2
1
2
3
4
5
6
Limit switch
Contact pointer
Connecting plug
Connecting terminal
Terminal socket
Information sign
19
Min
Max
Min 1
Max 1
Min 2
Max 2
2-wire technology
3-wire technology
Contact
Connector color
Labeling
2-wire technology
MIN
black
1
2
MAX
gray
4
5
20
Contact
Connector color
Labeling
3-wire technology
MIN
black
1
2
+
DC
MAX
gray
4
5
+
DC
Safety-oriented *
SJ3,5-SN and SJ3,5-S1N
Inputs
Input
Terminal
in the
display
Terminals
in the
display
Output I
Output II Power
Switch S1
Effective direction I
Switch S3
LB/LK detection
Switch S2
Effective
direction II
LB : Line break
LK : Line short-circuit
Output III
II
Output I
Power
LED yellow
Relay output
LED red
LB/LK detection
LED green
Power
* Safety-oriented isolation switching amplifiers
are only single-channel!
Connecting diagram
3-wire SB3,5-E2
21
Scale opening
22
1 mA
SJ3,5-S1N
1 mA
Min1
Min2
Current
consumption in
pointer position
shown
SJ3,5-S1N
3 mA
SC3,5-N0
3 mA
Max1
Max2
23
2-wire
SC3,5-N0-Y
NAMUR
NC contact
8V
2-wire
SJ3,5-SN
NAMUR
NC contact
8V
2-wire
SJ3,5-S1N
NAMUR
NO contact
8V
3-wire
SB3,5-E2
3 mA
1 mA
3 mA
1 mA
1 mA
3 mA
0.3 V
Ub - 3 V
max. 100 mA
15 mA
PNP NO contact
10 to 30 V
An isolation switching amplifier, e.g. Pepperl + Fuchs Series KF .. SR2 , is required in order to
operate the SC3,5-N0-Y limit switch (refer to Service section, list of spare parts).
SJ3,5-SN and SJ3,5-S1N limit switches in 2-wire technology, safety-oriented, are connected in
accordance with EN 60079-14 / IEC 60079-14 to a safety-oriented isolating switching amplifier,
e.g. Pepperl + Fuchs K SH- (large S on the front)
8.3
24
8.3.2 HART
TM
HARTTM communication is not absolutely necessary in order to operate the ESK II.
TM
When HART communication is carried out with the ESK II, this will not in any way impair analog
measured-data transmission (4...20mA)
TM
TM
TM
If a HART communicator (type Fisher Rosemount, Model 275) or a PC with HART modem C
is used, the series-connected resistor (Rext.) has to exceed 250 Ohms.
In this type of operation the auxiliary power must amount to at least 18 V. The communicator (or
PC) can be operated optionally via the connecting terminals of the ESK II (2) or via a seriesconnected external resistance (1).
The totalizer proper cannot be read out or operated by means of HART TM communication.
TM
communication is possible in
25
12 (18 *) to 30 V DC
4.00 to 20.00 mA for 0 to 100 % flow value
> 20.8 mA for alarm status
< 0.1%
< 0.1%
< 5 A / K
0 (250 * ) to 800 Ohms
8.4
TM
communication.
= 15...150 Ohm/km
= 0,4...1 mH/km
= 80...200 nF/km.
26
9 to 32 V DC
12 mA
< Basic current
< 18 mA
1.6
< 0.1 % of upper range value
< 0.05 % / K of upper range value
Software
GSD
Device profile
Function blocks
Flow rate (AI0)
Totalizer (TOT0)
Totalizer (TOT1)
Address range
SAP`s
DD
Operation
27
8.5
Display
Flow rate as %
Total value
Conversion factor
Deleting of the stored total value
Remark
Totalizing continues to run in the background.
E.g. liters or m3
Standard: 10% of Q100
* If galvanically isolated current evaluation modules (PLC) are used at Terminals 12/13,
the auxiliary power (11/12) may not be grounded.
If the ESK signal is only used for the totalizer, a short-circuit jumper is required at
Terminal 12/13.
28
Flow rate
in [%]
Totalizer
Conversion
factor
During the switching-on process keep the RESET button pressed until three decimal points
light up.
Set 4.00 mA and then keep Button 1 pressed until the number 0 is displayed
Set 20.00 mA and then keep Button 3 pressed until the number 100 is displayed
29
8.6
16 to 30 VDC
0 ... 600 Ohms
Max. 2 W
0 to 720 Ohm depending on the supply voltage
Terminal P+, P10 to 30 VDC
50 mA
250 mW
Fixed pulse width 80 ms
Depending on flow rate
Ub 3 Volt
0 Volt
1 pulse = 1 display totalizer advance
= 1 flow unit (1 liter, 1 m3, etc.)
- 25C to + 65C
< 1% of the displayed value,
maximum of one display unit
Converter ESK-S
Description
The converter ESK-S in 3-wire technology converts the current output signal of the ESK II into a
current signal of 0 ... 20 mA.
red
blue
30
18 ... 30 VDC
Max. 70 mA
4 ... 20 mA
0 ... 20 mA / 0 ... 100% flow rate
0 ... 600 Ohms
- 25 C to + 65C
< 0.35% of input signal
< 0.1%
< 0.2%
Service
Some components of the variable area flowmeter with M9 indicator can be retrofitted:
Float
Float damping
Eddy-current brake
Contacts Kmin, Kmax, K2
ESK II, if the indicator was ordered with ESK II preparation
Totalizer ESK-Z
ESK-S (0...20 mA converter)
9.1
31
9.2
Installation:
Remove the instrument from the pipeline.
Remove the upper snap ring (1) from the measuring unit.
Remove the upper float stop (5) and float from the measuring unit.
Fasten the snap ring (3) in the lower groove on the float guide rod.
Slide the ceramic sleeve (4) onto the float guide rod and fasten it in the
upper groove using the snap ring (3).
Insert the float into the lower float guide in the measuring unit.
Install the supplied damping cylinder with integrated float stop (2) into the
measuring unit.
Insert the upper snap ring (1).
9.3
Brake
Clamping bolt
32
9.4
Contact module
Installation
If provided, remove the ESK-Z flow totalizer
Bring the contact pointers (1) together in the center
Loosen the locking screw (2) of the contact pointers
Slide the contact module into the third rail until the
semicircle (3) encloses the pointer support.
The connecting terminals of the contact module have a
pluggable design and can be removed in order to
connect the lines.
9.5
33
Rext.
11 +
12 -
TM
4mA
20mA
ESK II
HARTTM
20
mA
34
However, every measuring unit is subject to its physical limits which the KroVaCal program
calculates correctly and, if appropriate, rejects the desired change. If a change is carried out with
the program, the new data are also transferred to the ESK II.
35
9.6
Installation:
Slide the existing scale out.
Slide the flow totalizer unit into the middle rail of the module support.
Then slide the new scale into the module support.
When sliding over the totalizer display, lift the scale slightly until the scale cutout frames the
totalizer display.
9.7
High-temperature design
36
The instrument can remain in the pipeline during the conversion to the HT version.
Magnet
Sealing ring
Compare the pointer position with the display value recorded beforehand. If the display value
deviates:
37
10
CIV 15
DIV 15
TIV 15
DVIT 15
1.4404
1.4404
1.4404
1.4404
X251041000
X251042000
X251043000
X251044000
Float
Float
TIV 15
TIV 15
Aluminium
Titanium
X251043100
X251043200
X251050100
X251050200
X251050300
X251053100
X251053200
DN 25
Float
Float
Float
Float
X252041000
X252042000
X252043000
X252044000
CIV 25
DIV 25
TIV 25
DVIT 25
1.4404
1.4404
1.4404
1.4404
X252050100
X252050200
X252050300
X252053100
X252053200
DN 50
Float
Float
Float
Float
X253041000
X253042000
X253043000
X253044000
CIV 55
DIV 55
TIV 55
DVIT 55
1.4404
1.4404
1.4404
1.4404
X253050100
X253050200
X253050300
X253053100
X253053200
38
Order No.
CIV 85
DIV 55
TIV 55
DVIT 55
1.4404
1.4404
1.4404 (special material Titanium = 468)
1.4404
X254041000
X254042000
X254043000
X254044000
X254050100
X254050200
X254050300
X254053100
X254053200
DN 100
Float
Float
Float
X255041000
X255042000
X255044000
CIV 105
DIV 105
DIVT 105
1.4404
1.4404
1.4404
Set: float stop, standard (1 stop, 1 snap ring) only for below!
Set: float stop; gas damping (AL2O3)
Set: float stop; gas damping (PEEK)
X255050100
X255050200
X255050300
X254053100
X254053200
M9 indicator
Indicator housing, complete, without scale
Cover M9 complete, standard (blue; RAL 5015)
Cover M9 complete, seawater-resistant (gray; RAL 7001)
Cover M9 complete, free of silicone (blue; RAL 5015)
Viewing window, multilayer glass
Viewing window, plastic (Macrolon)
Cover seal (silicone)
Baseplate M9, standard
Baseplate M9, seawater-resistant
Retrofit kit, HT extension
Module support (mounting channel)
Set: housing fastening parts (1 pair)
Pointer system, complete
Eddy-current brake
Scale printed (serial number required)
Scale blank
Scale printed with totalizer cut-out (serial number required)
Scale blank with totalizer cut-out
X251010000
X251010100
X251010200
X251010300
X251011100
X251011200
X251012100
X251020100
X251020200
X251021000
X251021100
X251021300
X251022100
X251022200
X251023100
X251023200
X251023300
X251023400
39
Order No.
M9 display (continued)
Retrofit kit ESK II, linearized (serial number required)
Retrofit kit ESK II (Ex), linearized (serial number required)
X251030100
X251030200
X251031900
X251032000
X251032100
X251033100
X251033200
X251033300
X251033400
X251033500
X251033600
X251033700
X251033800
X251033900
X251034000
X251034100
TM
4.00313.00.00
317850xx
5015262000
5015262100
5015262200
5015262300
5015262400
5015262500
11
1 channel
1 channel
1 channel
2 channels
2 channels
2 channels
Maintenance
The flowmeter should be inspected for soiling, corrosive wear and signs of mechanical wear or
damage to the measuring tube and the indicator in the context of the routine operational
maintenance of the installation and the pipelines. We recommend at least annual inspections.
In order to clean the instrument, remove it from the pipeline.
Note!
Pressurized pipes have to be depressurized before the measuring unit is
removed.
Appropriate safety precautions need to be taken with regard to residual liquids in
the measuring unit of devices used to measure aggressive media.
New gaskets must always be used when remounting the measuring unit in the
pipeline.
Electrostatic charges are to be avoided when the surfaces (e.g. viewing window)
are cleaned!
40
Notes
41
Notes
42
{ water-hazardous
{ toxic
{ caustic
{ flammable
we have
{ checked that all cavities in the instrument are free from such substances /
{ flushed out and neutralized all cavities in the device
We confirm that there is no risk to humans or environment through any residual liquid contained in this device.
Date: Signature:
Company stamp:
Installation and operating instructions H250/M9
43