Professional Documents
Culture Documents
H1
H2
H3
MODULES
H4
RELAYS
H5
INFORMATION ON SOLENOIDS
H6
Continuous Duty
24V Insulated
24063
36V Insulated
24080
2
24107
24144 200A
24080-01 UL-Listed
3
BAT +
MARINE
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
71
H1
24V Grounded
24420 Normally On
1
24124
12V Insulated
12V Grounded
24115
24106
1
BP
3
BAT +
24059
BP
2
24059-08 UL Listed
BP
24143 200A
MARINE
6V
24097 Insulated
LISTED
1
2
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
72
H1
Latching Solenoid
24200
Momentary
Switch
BAT
LOAD
Special Applications
See page 83.
Motor Reversing
Typical DC series wound permanent magnet circuit, using
a pair of double-action solenoids. Use pairs of the following
solenoids: 24401 (12V), 24402 (24V), or 24400 (36V).
SPDT
Control Switch
Fwd
Rev
2440X Series
Solenoid
2440X Series
Solenoid
1
To
Motor
+
6
BAT
BP
To
Motor
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
73
H1
Intermittent Duty
750A make, 100A break, 10sec On, 20min Off, except where
noted. Contacts: Copper. Terminals: Copper. Small ignition
and ground terminals are 10-32 thread. Large contact
terminals are 5/16" -24 thread. Hexnuts and lockwashers
are included. Bracket mounting holes 5/16 x 19/32, 2 13/64"
on centers (7.9 x 15.1, 56.0mm) and plated steel housing,
except where noted.
24V Insulated
24008
12V Grounded,
Resistor Shorting Circuit
24104
In this application, 3 is
Normally Open. It becomes
common with 1 and 4 when
the solenoid is energized.
Commonly used in engine
starting applications.
3
BAT +
3 RESISTOR
SHORTING
CIRCUIT
24103
12V Grounded
24037
M-202 Marine
Marine construction. Clear protective finish,
brass hexnuts and lockwashers.
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
74
H1
12V Insulated
24047
6V Grounded
24041
M-200 Marine
BAT +
BP
MARINE
24060
LISTED
2
1
3
BAT +
Electronic Solenoid
24046
BAT +
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
75
H2
Intermittent Duty
Continuous Duty
24076, Insulated
36V
24135
24077, Insulated
24V
MARINE
24063-08 UL Listed
Continuous Duty: 65A at 24V DC
LISTED
Intermittent Duty: 120A make, 65A break. 10 sec On, 30 min Off.
Without PVC coating and UL rating: see 24063
BAT +
12V
24071, Grounded
24117
24117-01 UL Listed
MARINE
BP
LISTED
12V SPDT
24401-04
Solenoid Info
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
76
H3
F bracket,
grounded
(one terminal)
F bracket,
insulated
(two terminals)
L bracket, insulated
(two terminals)
Grounded
Insulated
24V
24624-10 Insulated
BP
L bracket, 5/16" -24 large studs, two 10-32 stud coil terminals.
12V
F bracket, 5/16" -24 large studs, two 10-32 stud coil terminals.
24512-10 Insulated
24612 Insulated
L bracket, two 10-32 stud coil terminals.
24612-10 Insulated
F bracket, two 10-32 stud coil terminals.
24612-G10 Grounded
F bracket, one 10-32 stud coil terminals.
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
77
H3
L bracket
24824-01 24V
Silver contacts.
24812 12V
T1
Copper contacts.
BAT
T2
24812-01 12V
Silver contacts.
Forward
24812-04 12V
Copper contacts.
Reverse
Reversing Solenoid
New 58312 series rocker switches have long lasting LED lights
and high-visibility wrap-around lenses. See page 9.
BP
BAT
MOTOR
Super-Bright LEDs
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
78
H4
NEW
Specifications:
High performance silver tin oxide contacts assure long cycle life.
Specifications:
9 - 31V DC, 85A continuous or 175A intermittent.
BAT
+
Red
Black
Fully sealed to IP67 with high strength epoxy for total moisture protection.
LOAD
Ignition protected.
Tin-plated brass studs and hardware for corrosion resistance.
Red
+
LOAD
Black
Emergency Cutoff
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
79
H5
General purpose relays fit many vehicles. Typical applications include: lighting, starting, horn, heating and cooling.
Standard ISO terminal footprint for Form A (SPST), Form C
changeover (SPDT) and Form 2A (SPST, 2 terminals). Relays
are available sealed and unsealed (unsealed are supplied
with snap-in brackets.)
Form A (SPST)
0.662 [16.81]
87
0.331 [8.40]
0.705 [17.91]
86
Specifications:
30
85
30
85
86
87
FORM A TERMINALS
Form A (SPST)
with suppression
0.662 [16.81]
87
86
30
86
87
(+)
Form C (SPDT)
87
0.315 [8.00]
0.331 [8.40]
0.705 [17.91]
87a
86
30
85
86
87 87a
Form C (SPDT)
with suppression
Specifications:
Contact rating (Resistive load) at 20C:
12V DC: Normally Open 40A,
Normally Closed 30A.
24V DC: Normally Open 20A,
Normally Closed 15A.
Contact arrangement: Available as
Form A (SPST), Form C (SPDT) and
Form 2A (SPST, 2 terminals).
85
30
FORM C TERMINALS
0.662 [16.81]
87
0.315 [8.00]
0.331 [8.40]
0.705 [17.91]
87a
86
30
85
86
(-)
85
87 87a
30
(+)
RESISTOR OR DIODE
FORM C TERMINALS
30
Specifications:
Contact rating (Resistive load) at 20C:
12V DC: Normally Open 70A,
Normally Closed 60A.
24V DC: Normally Open 35A,
Normally Closed 30A.
Contact arrangement: Available as
Form A (SPST) and Form C (SPDT).
FORM A TERMINALS
0.662 [16.81]
BP
85
30
85
(-)
RESISTOR OR DIODE
0.331 [8.40]
0.705 [17.91]
85
86
30
87 87
85
(-)
86
87 87
(+)
RESISTOR OR DIODE
5
0.662 [16.81]
87
0.315 [8.00]
87
86
0.331 [8.40]
85
30
FORM 2 TERMINALS
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
80
H5
FORM
A: SPST
A: SPST
A: SPST
A: SPST
A: SPST
A: SPST
A: SPST
A: SPST
AMPERAGE
40
40
40
20
20
20
40
20
BRACKET
01 Snap-in
01 Snap-in
01 Snap-in
01 Snap-in
01 Snap-in
01 Snap-in
00 None
00 None
VOLTAGE
12
12
12
24
24
24
12
24
SUPPRESSOR
N: none
R: resistor
D: diode
N: none
R: resistor
D: diode
D: diode
D: diode
SEAL
N: no seal
N: no seal
N: no seal
N: no seal
N: no seal
N: no seal
S: sealed
S: sealed
PART NUMBER
RA-400112-NN
RA-400112-RN
RA-400112-DN
RA-200124-NN
RA-200124-RN
RA-200124-DN
RA-400012-DS
RA-200024-DS
C: SPDT
C: SPDT
C: SPDT
C: SPDT
C: SPDT
C: SPDT
C: SPDT
C: SPDT
40
40
40
20
20
20
40
20
01 Snap-in
01 Snap-in
01 Snap-in
01 Snap-in
01 Snap-in
01 Snap-in
00 None
00 None
2: SPST
2: SPST
20
40
A: SPST
A: SPST
A: SPST
C: SPDT
C: SPDT
C: SPDT
**DIAGRAM
1
2
2
1
2
2
2
2
12
12
12
24
24
24
12
24
N: none
R: resistor
D: diode
N: none
R: resistor
D: diode
D: diode
D: diode
N: no seal
N: no seal
N: no seal
N: no seal
N: no seal
N: no seal
S: sealed
S: sealed
RC-400112-NN
RC-400112-RN
RC-400112-DN
RC-200124-NN
RC-200124-RN
RC-200124-DN
RC-400012-DS
RC-200024-DS
3
4
4
3
4
4
4
4
01 Snap-in
01 Snap-in
24
12
R: resistor
R: resistor
N: no seal
N: no seal
R2-200124-RN
R2-400112-RN
5
5
70
70
70
01 Snap-in
01 Snap-in
01 Snap-in
12
12
12
N: none
R: resistor
D: diode
N: no seal
N: no seal
N: no seal
RA-700112-NN
RA-700112-RN
RA-700112-DN
1
2
2
70
70
70
01 Snap-in
01 Snap-in
01 Snap-in
12
12
12
N: none
R: resistor
D: diode
N: no seal
N: no seal
N: no seal
RC-700112-NN
RC-700112-RN
RC-700112-DN
3
4
4
40
A Form A (SPST)
01
12
C Form C (SPDT)
12 12V DC
24 24V DC
2 Form 2A (SPST,
2 terminals)
00 Without bracket*
01 With snap-in bracket
R Relay
M MicroRelay
15
20
25
35
40
70
15V at 24V DC
20A at 24V DC
25A at 24V DC
35A at 24V DC
40A at 12V DC
70A at 12V DC
Relay Sockets
S Sealed*
N Nothing (no sealing)
R Resistor
D Diode
N Nothing (no suppressor)
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
81
H5
MicroRelay Schematics
& Terminal Layouts
Form A (SPST)
0.662 [16.81]
0.551
87
0.610
0.906
85
86
MA-250012-NN
87
30
FORM A TERMINALS
Form A (SPST)
with suppression
0.453
0.551
0.705 [17.91]
0.35486
0.610
0.248
2 PLCS
0.906
0.030
TYP
30
DETAIL A
0.315
0.331 [8.40]
85
85
86
30
87
30
85
86
(-)
30
87
(+)
FORM A TERMINALS
RESISTOR OR DIODE
0.453
0305
85
86,87,87a
www.colehersee.com
FORM C TERMINALS
Form C (SPDT)
86
30
8530
85 86
30
85
86
86 87a
87 87a
87
(-)
(+)
SEE NOTE 11
RESISTOR OR DIODE
85
85
87
86
30[8.40]
0.331
0.177
87
0.705 [17.91]
30
0.453
FORM C TERMINALS
FORM C TERMINALS
Form C (SPDT)
with suppression
0.662 [16.81]
0.551
0.315
DETAIL D
0.315 [8.00]
FORM C (SPDT)
87
0.354
87a
86
87
R OR DIODE
87
0.354
87a
SEE NOTE 11
0.551
0.315
0.315 [8.00]
FORM C (SPDT)
ESISTOR OR DIODE
0.662 [16.81]
DETAIL D
(+)
30
87 87a
30
85
(-)
85 86
(-)
(+)
87
87a 87a
86 87
(+)
SEE NOTE 11
RESISTOR
OR DIODE
RESISTOR
OR DIODE
85
87
8586
30 [8.40]
0.331
0.177
0.705 [17.91]
87
30
0.453
FORM C TERMINALS
FORM
A: SPST
A: SPST
A: SPST
A: SPST
AMPERAGE
25
25
25
25
VOLTAGE
12
12
12
12
A: SPST
C: SPDT
C: SPDT
C: SPDT
15
25
25
25
C: SPDT
C: SPDT
C: SPDT
25
15
15
BP
87
0.662 [16.81]
87
30
86
FORM A TERMINALS
86,87,87a
www.colehersee.com
Specifications:
85
0.453
1.024
0305
85
0.331
30 [8.40]
30
87
85
86
85
86
30
30
DETAIL A
0.315
SUPPRESSOR
R: resistor
R: resistor
D: diode
N: none
SEAL
N: no seal
S: sealed
N: no seal
N: no seal
PART NUMBER
MA-250012-RN
MA-250012-RS
MA-250012-DN
MA-250012-NN
24
12
12
12
N: none
R: resistor
R: resistor
D: diode
N: no seal
N: no seal
S: sealed
N: no seal
MA-150024-NN
MC-250012-RN
MC-250012-RS
MC-250012-DN
6
9
9
9
12
24
24
N: none
R: resistor
N: none
N: no seal
N: no seal
N: no seal
MC-250012-NN
MC-150024-RN
MC-150024-NN
8
9
8
**DIAGRAM
7
7
7
7
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
82
85
86
87
H6
ALTERNATOR
BATTERY TERMINAL
3
HOUSING
COIL
B1
PLUNGER
4
+
LOAD CIRCUT STUDS
L MAIN LOAD
B2
L SECONDARY LOADS
L
Pilot Light
Energized solenoid
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
83
notes
For orders or questions please call (617) 268-2100 or visit us on the web at www.colehersee.com
All-weather hardware:
heavy copper studs and
brass nuts for maximum
current capacity.
Impact-Resistant
Water-Resistant
Corrosion-Proof
BP
Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.
84