Peru Block 67 Field Development

Specification
Equipment design conditions

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 1 of 32

SPECIFICATION
EQUIPMENT DESIGN CONDITIONS

02 IFD

Issued for Design

01 IFC

Issued for Comments

Rev Status Revision Memo

22-Jul-11

F.Le Frapper

03-May-11 F.Bessieres
Date

Written By

V. Fort

X.Grandiaud

F.Le Frapper

X.Grandiaud

Checked By

Approved By

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 2 of 32

INDEX

GENERAL ..................................................................................................................................................4

REFERENCE DOCUMENTS .....................................................................................................................4


2.1
2.2

Project Documents ............................................................................................................................4


Codes and Standards........................................................................................................................4

DEFINITIONS .............................................................................................................................................4

ABBREVIATIONS ......................................................................................................................................4

ENVIRONMENTAL AND SITE CONDITIONS...........................................................................................5


5.1
5.2
5.3
5.3.1
5.3.2
5.3.3
5.3.4
5.3.5
5.3.6

5.4
5.5
5.6
6

Facilities General Location................................................................................................................5


Facilities Coordinates ........................................................................................................................6
Environmental Conditions .................................................................................................................6
Ambient Air Temperature .............................................................................................................................6
6
Relative humidity ..........................................................................................................................................6
Solar Radiation.............................................................................................................................................6
Prevailing Wind ............................................................................................................................................6
Rain fall ........................................................................................................................................................7

Soil Characteristics............................................................................................................................7
Hydrological data...............................................................................................................................7
Seismic Data .....................................................................................................................................7

EQUIPMENT DESIGN CONDITIONS........................................................................................................8


6.1
6.2
6.3
6.4
6.5
6.6
6.6.1
6.6.2
6.6.3

Design life..........................................................................................................................................8
Temperature and humidity ................................................................................................................8
Blast Conditions ................................................................................................................................8
Design Conditions for Transportations..............................................................................................8
Flare Radiations ................................................................................................................................8
Environmental Pollution.....................................................................................................................9
Emissions for Hydrocarbon Installation Equipment ......................................................................................9
Emissions for Electrical Generators and Boilers...........................................................................................9
Rejected Water Regulation Performances Criteria.....................................................................................10

7
THE PRESENT PARAGRAPH CONCERNS ONLY RAINWATER AND FRESH WATER REJECT.
REQUIREMENT FOR OPEN DRAIN REJECT ARE IN HOLD. ......................................................................10
7.1.1

Noise ..........................................................................................................................................................10

UTILITY ....................................................................................................................................................11
8.1
8.1.1
8.1.2
8.1.3

8.2
8.2.1
8.2.2
8.2.3

8.3
8.3.1
8.3.2
8.3.3

Electrical..........................................................................................................................................11
Piraa CPF.................................................................................................................................................11
Curaray Terminal........................................................................................................................................12
Piraa PPiX ................................................................................................................................................13

Fuel Gas..........................................................................................................................................13
Fuel Gas Design.........................................................................................................................................13
13
Fuel Gas Composition ................................................................................................................................14

Diesel Oil .........................................................................................................................................15


Piraa CPF.................................................................................................................................................15
Curaray Terminal........................................................................................................................................15
Diesel Oil Composition ...............................................................................................................................16

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions
8.4
8.5
8.5.1
8.5.2
8.5.3

8.6
8.7
8.7.1
8.7.2
8.7.3
8.7.4
8.7.5
8.7.6

8.8
8.8.2

8.9
8.9.1
8.9.2

8.10

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 3 of 32

Crude Oil .........................................................................................................................................18


Instrument Air ..................................................................................................................................20
Piraa CPF.................................................................................................................................................20
Curaray Terminal........................................................................................................................................20
Piraa PPiX ................................................................................................................................................20

Nitrogen...........................................................................................................................................20
Chemical Injection ...........................................................................................................................21
Piraa CPF.................................................................................................................................................21
22
Arabela River Water Pumpng Station........................................................................................................22
22
Piraa PPiX ................................................................................................................................................22
Curaray Terminal........................................................................................................................................23

Utility Water .....................................................................................................................................23


23

Potable water ..................................................................................................................................27


Potable Water Design data.........................................................................................................................27
Potable Water Quality ................................................................................................................................27

Fire Water.......................................................................................................................................31

8.10.1 Fire Water Design data ..............................................................................................................................31


Note 1 : the firewater ring main at CT is not pressurised and dry during normal operation. When required, the ring
main is fed by two fire water pumps discharging firewater at 8.7 barg (working) minimum (12.5 barg design). ........31
8.10.2 Fire Water Composition..............................................................................................................................31

8.11
8.12
8.13
8.14

Foam ...............................................................................................................................................31
MP Flare Network............................................................................................................................32
LP Flare Network.............................................................................................................................32
Thermal Oil......................................................................................................................................32

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 4 of 32

GENERAL

The purpose of this document is to list the project data for the mechanical design and specifications of
equipment relevant to the Peru Block 67 Field Development (Piraa CPF, CT and pads PPi1 and PPi3).
This is a general specification. All specific required data shall be found in the dedicated equipment
specification or data sheet.
2

REFERENCE DOCUMENTS

2.1

Project Documents

[1]

PP67-PE-GEN-00-DOR-RP-I-001

Geological and Geotechnical Synthesis Report

[2]

PP67-PE-GEN-00-DOR-RP-I-002

Hydrological Synthesis Report

2.2

Codes and Standards

[3]

DS 062-2010-PCB/ 7th October 2010

Aprueban LMP emisiones gaseosas

[4]

Norma E.030 (2006)

Diseo Sismorresistente

[5]

Ministerio de Salud del Peru

[6]

World Bank Group

El reglamento de la Calidad del Agua para


Consumo Humano
Air emissions and ambient air quality

DEFINITIONS

Company

Perenco Peru Petroleum Limited

Contractor

DORIS Engineering

ABBREVIATIONS

AMB

Ambient

ATM

Atmosphere

CO2

Carbon Dioxyde

CPF

Central Processing Facilities

DLB

Design Level Blast

HP

High Pressure

LHV

Lower Heating Value

LP

Low Pressure

NO2

Nitrogen Dioxide

SLB

Strength Level Blast

SO2

Sulphur Dioxide

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions
5
5.1

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 5 of 32

ENVIRONMENTAL AND SITE CONDITIONS


Facilities General Location

The site is located on the Maranon Basin in the north-east part of the Peru and is situated in the Amazon
rainforest between the Andean Cordillera and the Guyana Shield. Altitude is comprised between 140 m and
200 m above sea water level.

Phase 0 will focus on Piraa field (CPF, PPi1 and PPi3) and CT:

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Peru Block 67 Field Development


Specification
Equipment design conditions
5.2

Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 6 of 32

Facilities Coordinates

Location

Reference Point

East

North

Elevation above
MASL

CURARAY TERMINAL

AS PER EIA

455586.00

9827611.00

160 m

PIRAA CPF

AS PER EIA

458762.00

9788030.00

173 m

PIRAA 2D

45968838

9787571.78

AS PER EIA

459710.00

9787630.00

PIRAA 3D

458880.00

9783999.97

AS PER EIA

45887600

9783999.00

PPI1

171 m

PPI3

5.3
5.3.1

178 m

Environmental Conditions
Ambient Air Temperature

Minimum dry-bulb temperature in winter (C)

Minimum dry-bulb temperature in summer (C)

18.5

28

5.3.2

5.3.3

Relative humidity
Minimum Humidity (%)

Maximum Humidity (%)

80

92

Solar Radiation

Solar radiation (maximum) = 0.98 kW /m2


5.3.4

Prevailing Wind

Minimum wind is 0ms which is actually the most often case with time frequency of 47%.
Prevailing directions is from North, for 22.8%, with a mean maximal speed of 1.8 m/s and East, for 19.5%,
with a mean maximal speed of 1.6 m/s.
The following design wind speed above ground level shall be considered in all directions:
All directions-Design Wind Speed
Return Period
Wind Speed (m/s)

1 year
6

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

100 years
19

Peru Block 67 Field Development


Specification
Equipment design conditions
5.3.5

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 7 of 32

Rain fall
Yearly

Monthly Maximum

Daily Maximum

540 mm
5.4

132 mm

Minimum

Mean

Maximum

2180 mm

3460 mm

5760 mm

Soil Characteristics

Geological and geotechnical data shall be extracted from the geological and geotechnical synthesis report
Ref. [1].
5.5

Hydrological data

Hydrological data shall be extracted from the Hydrological Synthesis Report Ref. [2].
5.6

Seismic Data

According to Peruvian standards for seismic design (Ref. [4]), the project site is characterized in the following
way:
Site parameter: Zone 1 corresponding to a zone factor of Z=0.15,
Type of soil profile S3 (conservative) on all sites corresponding to a soil amplification factor S of 1.4,
Facilities category of importance A: essential facilities corresponding to a U-factor of 1.5.
Seismic design base shear shall then be computed according the methodology proposed in Ref. [4] for
structural elements and non-structural elements (article 23 respectively).
The following maximum accelerations shall then be considered:
Equipments, tanks, piping : H = 0.29g.
According to Ref. [4], no vertical seism acceleration shall be considered for zone 1.

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Peru Block 67 Field Development


Specification
Equipment design conditions

Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 8 of 32

EQUIPMENT DESIGN CONDITIONS

6.1

Design life

The equipment shall be designed for a minimum life of 20 years.


6.2

Temperature and humidity

Depending on equipment location, following Air design data shall be considered:


Location of equipment

Air design Temperature (C)


Min
18.5
22

Outdoors
Buildings

Air Humidity design range (%)

Max
28
26

80/92
45/55

The design temperature for guaranteed performance of air cooling system is 28C.
The black body temperature is the temperature induced by solar radiation on metal equipment. This is the
minimum value for the design temperature and shall be taken into account only for equipment and piping
located outdoor. Black Body Temperature = 43 C.
6.3

Blast Conditions

Blast event shall not be considered for equipment design.


6.4

Design Conditions for Transportations

Equipment shall be designed to withstand here below accelerations in case of sea transportation to site:
Acceleration (g)
Roll and Pitch
heave

0.9
0.8

Equipment shall be designed to withstand here below accelerations in case of road transportation to site:
Acceleration (g)
Longitudinally
Vertical & Transverse
6.5

0.3
0.1

Flare Radiations

Equipments shall be designated to sustain the following radiations:


System
Emergency Flaring
kW/m
Btu/hr/ft
Flare drum
6.3
2000
Flare piping
9.5
3000
Atmospheric storage
3.2
1000
Pressure vessel storage
2.0
630
Process equipment
4.7
1500

4.7
4.7
2.4
1.6
3.2

Max continous flaring


kW/m
Btu/hr/ft
1500
1500
750
500
1000

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions
6.6

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 9 of 32

Environmental Pollution

6.6.1 Emissions for Hydrocarbon Installation Equipment


Latest Peruvian reglementation for hydrocarbon installation emissions is supplied in the Decree DS-0622010-PCB Aprueban LMP emisiones gaseosas dated of the 7th October 2010 [6]. The concerned
specification is showed in the following table related to new hydrocarbon installations:
Regular Parameters
Particulate Matter (PM)
Organic Volatile compounds (COV)
Sulfur Oxid (SOx)
- Sulphur recovery unit
- Other units
Nitrogen Oxid (NOx)
- Using combustible gas
- Using combustible oil
Nickel (Ni)
Vanadium (V)

Activities of Processing and Refining


Oil
(mg/Nm)
50
20
N/A
150
500
450
N/A
N/A
1
5

6.6.2 Emissions for Electrical Generators and Boilers


As far electrical installations are concerned, unless a new Peruvian Decree is entered in force, the World
Bank shall apply.

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Peru Block 67 Field Development


Specification
Equipment design conditions

Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 10 of 32

6.6.3 Rejected Water Regulation Performances Criteria


The present paragraph concerns only rainwater and fresh water reject. Requirement for open drain reject are
in HOLD.
Waste Water Discharge Standards
Parameter
TPH
Chloride
Chrome (VI)
Total Chrome
Mercury
Cadmium
Arsenic
Phenol for FCC discharge of refinery
Sulphur for FCC discharge of refinery
BOD
COD
Residual chlorine
Ammoniac nitrogen
Total Coniforms (NMP/100mL)
Fecal Coniforms (NMP/100 mL)
Phosphorus
Barium
pH
Oil and Grease
lead
Increase of temperature (with regard to ambient
temperature of the receiver, measured at a distance
of 100m from the discharge point)

Mg/l
20 ppmv
500 (Rivers, lakes, reservoirs)
0.1
0.5
0.02
0.1
0.2
0.5
1.0
50
250
0.2
40
<1000
<400
2
5.0
6.0-9.0
20
0.1
<3C

6.6.4 Noise
For each noisy equipment, reference shall be made to the dedicated data sheet and / or specification
providing the equipment maximum sound pressure (SPL) at 1 m.

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions
7

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 11 of 32

UTILITY

7.1
7.1.1

Electrical
Piraa CPF

Nominal Voltage

Operational
voltage
Range

Neutral System

Service

Internal
Power
Generation
6.6 kV AC 60 Hz
(3ph 3 wire)
Internal
Power
Generation
480V AC 60 Hz
(3ph 3 wire)

5%

Earthed by Earthing
transformer

5%

6.6 kV AC 60 Hz
(3ph 3 wire)

5%

33 kV AC 60 Hz
(3ph 3 wire)
480 V AC 60 Hz
(3ph 3 wire)

5%

Earthed by high
Emergency Power
impedance (IT
system)
Neutral not
distributed
Power Distribution
Earthed by Earthing
HV motors
transformer
HV / LV transformers
HV / HV transformers
Earthed trough an
Well pads supply
impedance
IT system With
MCC
permanent insulation Main LV distribution
monitoring
Motors
Neutral not
LV voltage transformer
distributed
230 V AC UPS

400/230 V AC
60 Hz
(3ph 4 wire)

5%

5%

Normal Power

TNS neutral earthed


and distributed

Lighting distribution board


Lightings fittings
Small distribution system
and sockets
Welding sockets
Heat tracing and motor
space heaters
Vital Power
Control and Safety
systems (PCS, PSS, ESD
and FGS)
Instrumentation,
All telecommunications
Generator 48 V DC
Vital Power
Control of HV and LV
switchgear

230 V AC UPS
60 Hz
(2 ph 2 wire)

10 %

Isolated IT system
With permanent
insulation monitoring
(neutral not
distributed)

48 V DC
(2 pole 2 wire)

10 %

Unearthed system
With permanent
insulation monitoring

Maximum
voltage drop
at equipment
terminals

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

5%
5%
5%
5%
2%
5%
2%

8 % max to the
farthest fitting

Peru Block 67 Field Development


Specification
Equipment design conditions
7.1.2

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 12 of 32

Curaray Terminal

Nominal Voltage

Operational
voltage
Range

Internal
Power
Generation
480 V AC 60 Hz
(3ph 3 wire)

5%

480 V AC 60 Hz
(3ph 3 wire)

5%

400/230 V AC
60 Hz
(3ph 4 wire)

5%

Neutral System
Earthed by high
impedance (IT system)
Neutral not distributed

Service
Normal power
Emergency power

Power Distribution
IT system With
MCC
permanent insulation
Main LV distribution
monitoring
Motors
Neutral not distributed LV voltage transformer
230 V AC UPS
TNS neutral earthed
Lighting distribution board
and distributed
Lightings fittings

230 V AC UPS
60 Hz
(2 ph 2 wire)

10 %

Isolated IT system
With permanent
insulation monitoring
(neutral not
distributed)

48 V DC
(2 pole 2 wire)

10 %

Unearthed system
With permanent
insulation monitoring

Maximum
voltage drop
at equipment
terminals

Small distribution system


and sockets
Welding sockets
Heat tracing and motor
space heaters
Vital power:
Control and Safety
systems (PCS, PSS, ESD
and FGS)
Instrumentation,
All telecommunications
Generator 48V DC
Vital power:
Control LV switchgear

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

2%
5%
2%
8 % max to the
farthest fitting

Peru Block 67 Field Development


Specification
Equipment design conditions
7.1.3

Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 13 of 32

Piraa PPiX

Nominal Voltage

Operational
voltage
Range

33 kV AC 60 Hz
(3ph 3 wire)

5%

480 V AC 60 Hz
(3ph 3 wire)

5%

400/230 V AC
60 Hz
(3ph 4 wire)

5%

Neutral System

Service

Power Distribution
Earthed trough an
HV / LV transformers
impedance
IT system With
permanent insulation
monitoring
Neutral not
distributed

MCC
Main LV distribution
Motors
LV voltage transformer
230 V AC UPS

TNS neutral earthed


and distributed

Lighting distribution board


Lightings fittings
Small distribution system
and sockets
Welding sockets
Heat tracing and motor
space heaters
Vital Power
Control and Safety
systems (PCS, PSS, ESD
and FGS)
Instrumentation,
Telecommunications
Generator 48 V DC
Vital Power
Control of HV and LV
switchgear

230 V AC UPS
60 Hz
(2 ph 2 wire)

10 %

Isolated IT system
With permanent
insulation monitoring
(neutral not
distributed)

48 V DC
(2 pole 2 wire)

10 %

Unearthed system
With permanent
insulation monitoring

7.2

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Fuel Gas

7.2.1 Fuel Gas Design


The fuel gas system design data is as follows:
Design temperature (C)
Operating Temperature (C)
Design Pressure (barg)
Operating Pressure (barg)
LHV (MJ/Sm)
Molecular Weight
Filtration
Water Content (% mol)

115
50
13
1.5 / 2
53.72 / 56.97
33.49 / 35.07
None
5

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Maximum
voltage drop
at equipment
terminals
5%
2%
5%
2%

8 % max to the
farthest fitting

Peru Block 67 Field Development


Specification
Equipment design conditions

7.2.2

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 14 of 32

Fuel Gas Composition

Gas Composition
CO2
Nitrogen
Methane
Ethane
Propane
i-Butane
n-Butane
i-Pentane
n-Pentane
n-Hexane
Mcyclopentan
Benzene
Cyclohexane
n-Heptane
Mcyclohexane
Toluene
n-Octane
E-Benzene
m-Xylene
o-Xylene
C9*
C10*
C11*
C12*
C13*
C14*
C15*
C16*
C17*
C18*
C19*
C20+ - Cetico (UP)*
C20+ - Glauconitico*
C20+ - Dorado*
C20+ - Paiche*
H2O
NBP[0]-2*
NBP[0]-13*
NBP[0]-27*
NBP[0]-42*
NBP[0]-56*
NBP[0]-70*
NBP[0]-85*
NBP[0]-99*
NBP[0]-113*
NBP[0]-127*
NBP[0]-141*
NBP[0]-156*
NBP[0]-171*

Phase 0 - Dehydrator Train


6.408205
9.684670
44.223432
4.965198
6.619640
1.115466
1.566770
0.395510
0.298777
0.225732
0.104592
0.017951
0.042592
0.078663
0.034470
0.004761
0.023971
0.001190
0.001266
0.000962
0.007616
0.002163
0.000649
0.000208
0.000091
0.000023
0.000005
0.000001
0.000000
0.000000
0.000000
0.000000
0.000000
0.000000
0.000000
4.113889
3.162835
2.711475
2.832649
3.097992
2.740320
2.262467
1.610317
0.942933
0.458942
0.180499
0.048607
0.010097
0.002407

% Mole
Phase 0 - Centrifuge Train
6.493482
9.564435
43.882450
5.040715
6.734889
1.132354
1.588743
0.399531
0.301448
0.226365
0.104838
0.017990
0.042634
0.078391
0.034355
0.004740
0.023777
0.001180
0.001254
0.000953
0.007539
0.002138
0.000641
0.000205
0.000090
0.000023
0.000005
0.000001
0.000000
0.000000
0.000000
0.000000
0.000000
0.000000
0.000000
4.113583
3.206155
2.744036
2.861083
3.122127
2.755021
2.268112
1.609505
0.939588
0.456120
0.179002
0.048134
0.009988
0.002379

Phase 1
6.075222
10.434824
47.399612
4.801487
5.869281
0.942265
1.311905
0.329460
0.250440
0.203492
0.095726
0.016600
0.040089
0.080358
0.035454
0.005072
0.027556
0.001410
0.001517
0.001161
0.009292
0.002723
0.000821
0.000262
0.000114
0.000029
0.000006
0.000001
0.000000
0.000000
0.000000
0.000000
0.000000
0.000000
0.000000
4.117196
2.699418
2.298340
2.406558
2.669397
2.424642
2.090232
1.573581
0.984944
0.511154
0.212865
0.059668
0.012745
0.003080

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Peru Block 67 Field Development


Specification
Equipment design conditions

7.3
7.3.1

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 15 of 32

Diesel Oil
Piraa CPF
Pressure
Temperature
Coarse
Filtration
Water
Filtration

7.3.2

Revision: 02

Design
Working
Design min/max
Working

6 barg
2.4 /1.4 barg
43C
Ambient

25 microns and larger


15 ppm vol maximum

Curaray Terminal
Pressure
Temperature
Coarse
Filtration
Water
Filtration

Design
Working
Design
Working

3.5 barg
1.2 / 0.2 barg
43C
Ambient

25 microns and larger


15 ppm vol maximum

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions
7.3.3

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 16 of 32

Diesel Oil Composition

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 17 of 32

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Peru Block 67 Field Development


Specification
Equipment design conditions

7.4

Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 18 of 32

Crude Oil

Temperature
Pressure

Visco @ 25C
Visco @ 50C
LHV
flash point
Composition
CO2
Nitrogen
Methane
Ethane
Propane
i-Butane
n-Butane
i-Pentane
n-Pentane
n-Hexane
Mcyclopentan
Benzene
Cyclohexane
n-Heptane
Mcyclohexane
Toluene
n-Octane
E-Benzene
m-Xylene
o-Xylene
C9*
C10*
C11*
C12*
C13*
C14*
C15*
C16*
C17*
C18*
C19*
C20+ - Cetico
(UP)*

Design
Working
Design min/max
Working

cSt
cSt
C
% mol

18 / 93 C
50 C
5 barg
2 / 0 barg

Oil with naphta

Oil after Heating


up at 150C

620
175
4,86

3587
601
61,18

0,084826
0,005287
0,049979
0,096708
0,428802
0,160902
0,290779
0,161725
0,151795
0,350048
0,171287
0,029061
0,089910
0,446226
0,187801
0,033373
0,616425
0,038134
0,051320
0,044295
0,647534
0,909530
0,991209
1,063355
1,454230
1,425456
1,508136
1,379510
1,347279
1,416511
1,396849

0,00276849
0,000164188
0,001512844
0,003704652
0,026229212
0,01550549
0,032506046
0,029511006
0,030969857
0,124953434
0,063071872
0,010481691
0,036942901
0,254549926
0,108644022
0,019957972
0,50778124
0,03238534
0,045090525
0,039946308
0,654480205
1,097653117
1,308808928
1,486928086
2,107318427
2,122521028
2,287233734
2,113085674
2,075596704
2,188390994
2,16115272

10,280147

15,94475274

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions
C20+ Glauconitico*
C20+ - Dorado*
C20+ - Paiche*
H2O
NBP[0]-2*
NBP[0]-13*
NBP[0]-27*
NBP[0]-42*
NBP[0]-56*
NBP[0]-70*
NBP[0]-85*
NBP[0]-99*
NBP[0]-113*
NBP[0]-127*
NBP[0]-141*
NBP[0]-156*
NBP[0]-171*
Diluant

% mol
% vol

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 19 of 32

26,218735
0,000000
0,000000
9,194673
0,639348
0,778508
1,189893
1,959300
2,658552
3,658208
4,617904
5,324140
5,406859
4,925860
3,122222
1,769961
1,227407

40,66588383
0,000000
0,000000
0,028686397
0,079012188
0,117969406
0,224097841
0,459885395
0,771635288
1,333047775
2,10064298
3,021802787
3,73900863
4,085715026
2,99999371
1,942651105
1,495368276

37,278162
16

22,370830
7,51

Additional compounds to be considered :


Sulfur

Oil
2.5

Wt%

Oil + Naphta
2.3 Wt%

Nickel

96

ppm

91

Iron

11

ppm

6.4 ppm

Vanadium

358 ppm

324 ppm

Asphaltene (C7 insolubles)

11.9 Wt%

9.5 Wt%

Salt

10

10

BS& W

0.5 %

ptb max

ppm

ptb max

0.5 %

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

7.5
7.5.1

Status: IFD

Class: 1

Page 20 of 32

Design
Working
Design
Pressure
Working
Oil and Particle contents
Water dew point

18C/72C
18.5C/38C
11 barg
9 barg
ISO 8573-1 Class2
ISO 8573-1 Class2

Design
Working
Design
Pressure
Working
Oil and Particle contents
Water dew point

18C/72C
18.5C/38C
10 barg
8 barg
ISO 8573-1 Class2
ISO 8573-1 Class2

Design
Working
Design
Pressure
Working
Oil and Particle contents
Water dew point

18C/72C
18.5C/38C
10 barg
8 barg
ISO 8573-1 Class2
ISO 8573-1 Class2

Design
Operating
Design
Normal

18C/72C
18.5C/38C
11 barg
7.7 barg
98%
Oil Free
ISO 8573-1 Class2

Curaray Terminal

Piraa PPiX
Temperature

7.6

Rev Date : 22-Jul-2011

Piraa CPF

Temperature

7.5.3

Revision: 02

Instrument Air

Temperature

7.5.2

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Nitrogen
Temperature
Pressure
Purity
Oil content
Water Dew Point

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

7.7

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 21 of 32

Chemical Injection

7.7.1
7.7.1.1

Piraa CPF
Anti-Fouling
Temperature
Pressure

7.7.1.2

Design min/max
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
Atm 10 barg

Design min/max
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
Atm 10 barg

Design min/max
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
Atm 13 barg

Design min/max
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
Atm 13 barg

Design min/max
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
Atm 13 barg

Design min/max
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
Atm 13 barg

Demulsifier

:
Temperature
Pressure
7.7.1.3

Anti-Foam
Temperature
Pressure

7.7.1.4

Corrosion inhibitor
Temperature
Pressure

7.7.1.5

Acid
Temperature
Pressure

7.7.1.6

Biocide
Temperature
Pressure

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions
7.7.1.7

Pressure

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 22 of 32

Design min/max
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
Atm 13 barg

Design min/max
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
Atm 13 barg

Design min/max
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
Atm 13 barg

Reverse Demulsifier
Temperature
Pressure

7.7.1.9

Revision: 02

O2 scavenger
Temperature

7.7.1.8

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

High Temperature Oil Demulsifier


Temperature
Pressure

7.7.1.10 High Temperature Corrosion Inhibitor


Temperature
Pressure
7.7.2
7.7.2.1

Design min/max
Operating
Design
Normal

Arabela River Water Pumpng Station


Biocide
Temperature

Design min/max
Operating
Design

Pressure
Normal

7.7.3
7.7.3.1

18/43 C
Ambient
15.6 barg
Atm 13 barg

18/43 C
Ambient
Tank Full of
Liquid
Atm

Piraa PPiX
Oil Demulsifier
Temperature
Pressure

Design min/max
Operating
Design
Normal

18/43 C
Ambient
93 barg
16 barg

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Peru Block 67 Field Development


Specification
Equipment design conditions
7.7.3.2

Pressure

Status: IFD

Class: 1

Page 23 of 32

Design
Operating
Design
Normal

18/43 C
Ambient
93 barg
16 47 barg

Design
Operating
Design
Normal

18/43 C
Ambient
15.6 barg
3 barg

Curaray Terminal

7.7.4.1

Corrosion inhibitor
Temperature
Pressure

7.7.4.2

Biocide
Temperature

Design min/max
Operating
Design

Pressure
Normal
7.8

Rev Date : 22-Jul-2011

Corrosion inhibitor
Temperature

7.7.4

Revision: 02

18/43 C
Ambient
Tank Full of
Liquid
Atm

Utility Water

7.8.1.1

Piraa CPF

Temperature
Pressure
Coarse
Filtration

Design
Working
Design
Working

18 / 43C
Ambient
13 barg
11 barg
100 microns

Water shall be sourced to Piraa CPF from Arabela River. Water composition from Arabela River is resumed
on the following table:

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 24 of 32

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 25 of 32

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

7.8.1.2

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 26 of 32

Curaray Terminal
Temperature
Pressure
Coarse
Filtration

Design
Working
Design
Working

18/43 C
Ambient
13 barg
11 barg
100 microns

Water shall be sourced to the Curaray Terminal from Curaray river. Water composition from Curaray River is
resumed on the following table:

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

7.9

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 27 of 32

Potable water

7.9.1
7.9.1.1

Potable Water Design data


Piraa CPF

Temperature

Design
Working
Design

Pressure

7.9.1.2

Working

18/43 C
Ambient
15 barg
6.7 barg

Curaray Terminal
Temperature

Design
Working
Design

Pressure

Working

18/43 C
Ambient
15 barg
6.7 barg

7.9.2 Potable Water Quality


Potable water quality requirements are extracted from: El reglamento de la Calidad del Agua para Consumo
Humano from Peruvian Health ministry [5].

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 28 of 32

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 29 of 32

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Peru Block 67 Field Development


Specification
Equipment design conditions

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100


Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 30 of 32

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Peru Block 67 Field Development


Specification
Equipment design conditions

Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 31 of 32

7.10 Fire Water


7.10.1 Fire Water Design data

7.10.1.1 Piraa CPF

Temperature

Design

18/43 C

Working

Ambient

Design
Pressure

12.5 barg

Working

Coarse
Filtration

8.8 barg
100 microns

7.10.1.2 Curaray Terminal


Temperature

Design

18/43 C

Working

Ambient

Design
Pressure

Note 1

Working

Coarse
Filtration

Note 1
100 microns

Note 1 : the firewater ring main at CT is not pressurised and dry during normal operation. When required, the
ring main is fed by two fire water pumps discharging firewater at 8.7 barg (working) minimum (12.5 barg
design).
7.10.2 Fire Water Composition
Fire water composition is assumed to be the same as Curaray River for CT and as Arabela River for Piraa
CPF.

7.11 Foam
Design min/max
18/43 C

Temperature
Operating
Pressure

Design
Normal

Ambient
10 barg Note 1

Note 1 ; To be confirmed by Vendor

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc

Doc. Ref.: PP67-PE-GEN-00-DOR-SP-O-100

Peru Block 67 Field Development


Specification
Equipment design conditions

Revision: 02

Rev Date : 22-Jul-2011

Status: IFD

Class: 1

Page 32 of 32

7.12 MP Flare Network

Temperature
Pressure

Max. Design

10 / 135 C

Normal

AMB

Design

3.5 barg

Normal

ATM

Max. Design

10 / 115 C

Normal

AMB

Design

3.5 barg

Normal

ATM

7.13 LP Flare Network

Temperature
Pressure
7.14 Thermal Oil

Type and Characteristics

To be confirmed by Fired Heater


Supplier

Design Pressure (barg)

11.3

Working Pressure (barg)

2/6

Design Temperature (C)

18 / 270

Working Supply Temperature


(C)

230

Working Return Temperature


(C)

160

WARNING: This document as printed may not be the latest version. Please refer to the electronic file in the EDMS
R:\652284\Typing\Docs\Native\Documents\O-Mechanical\PP67-PE-GEN-00-DOR-SP-O-100_rev02- Specifications - Equipment Design Conditions.doc