You are on page 1of 3

PROPOSED ISLA LPG CORPORATION HEADQUARTERS

14th Floor City Bank Center, 8741 Paseo de Roxas Ave, Makati City

DIVISION
SECTION
PART 1

6
06402

WOOD, PLASTIC & COMPOSITES


Interior Architectural Woodwork

GENERAL

1.1 PROJECT INCLUDES:


A

Casework

Door frames and jambs

1.2 QUALITY ASSURANCE


A.

Conform to Architectural Woodwork Institute (AWI) - Architectural


Woodwork Quality Standards.

B.

Conform to Woodwork Institute of California (WIC) Manual of Millwork.

C.

Fire-retardant Treatment

PART 2

Lumber: see AWPA standards, non-corrosive interior type

Plywood: see AWPA standards, non-corrosive interior type

MATERIALS

2.1 PRODUCTS
A

Interior Wood Casework


1
2

Casework Hardware and Auxiliary Materials


1

Tanguile / Narra for transparent and opaque finish


Grade: Premium

Manufacturer:

Dorma or approved equal

Interior frames and Jambs


1 Tanguile / Narra
2 Grade: Premium

Auxiliary Materials
1 Screws:
2 Nails:
3 Anchors:

Any type suitable for the purpose


Any type suitable for the purpose
Type required for secured anchorage

Interior Architectural Woodwork


06402
V.R. Benito Architectural Services

Page 1 / 3

Date 11/06/2009
Rev. Date //

PROPOSED ISLA LPG CORPORATION HEADQUARTERS


14th Floor City Bank Center, 8741 Paseo de Roxas Ave, Makati City

DIVISION
SECTION
3

6
06402

WOOD, PLASTIC & COMPOSITES


Interior Architectural Woodwork

EXECUTION

3.1 QUALITY LUMBER


A

Lumber shall be of approved quality of the respective kinds required for the
various parts of the work, well-seasoned, thoroughly dry and free from large,
loose or unsound knots, saps, shakes or other imperfections impairing its
strength durability or appearance.

Framing lumber shall be of rough dimensions shown on Drawings.

All exposed woodwork shall be smoothly dressed and well sand- papered.

3.2 SCHEDULE OF LUMBER


Use the following wood as required in the Drawings:
A Yacal (kiln-dried)
1 Wood plate and other lumber embedded or in contact with concrete,
masonry or plaster work, except those specified as pressure-treated with
copper Chromate Arsenic Salt Solution type-C.
B

Guijo (kiln-dried)
1

Apitong (pressure-treated with Copper Chromate Arsenic Salt Solution CCA-C)


1

For all door jambs and other wall openings with wood frames.

All frame work for double plywood partitions vertical and horizontal
studs 50 mm x 76 mm, etc, where required.

Tanguile/Narra (Kiln-Dried)
1

All interior frame work for counters, cabinets, closets, and shelvings.

Doors, etc. (Verify door details)

3 All base board and other moulding requirements.


3.3 TREATMENT OF LUMBER
A

Lumber shall be well seasoned and kiln-dried to maximum moisture content


of 15% except Yacal which shall not be more than 12%.

Interior Architectural Woodwork


06402
V.R. Benito Architectural Services

Page 2 / 3

Date 11/06/2009
Rev. Date //

PROPOSED ISLA LPG CORPORATION HEADQUARTERS


14th Floor City Bank Center, 8741 Paseo de Roxas Ave, Makati City

DIVISION
SECTION

6
06402

WOOD, PLASTIC & COMPOSITES


Interior Architectural Woodwork

Lumber shall be pressure-treated with Copper Chromate Arsenic Salt


Solution or approved equal. Accompany lumber with certificate from lumber
company, certifying treatment amount, moisture percentage after kiln-drying.

Surface in contact with masonry and concrete shall be coated with creosote.

3.4 PLYWOOD
A

Plywood Materials
1 All plywood shall be free from knots, splits and other open defects, with
smooth surface suitable to receive finish.

3.5 WORKMANSHIP
A. Rough carpentry shall be executed in best, substantial, workmanlike
manner. Framing shall be erected true to line, levels and dimensions,
squared, aligned, plumbed, well spiked and nailed, adequately braced and
fitted, using mortise and tendon joints where practical.
B. Millwork shall be accurately milled to details as approved in manner to
allow free play of panels, avoid swelling, shrinkage, insure work remaining
in place without warping, splitting, or opening of joints. Millwork shall not be
installed until concrete and masonry work have been cured and will not
release moisture harmful to woodwork.
3.6 HARDWARE INSTALLATION
A

Hardware shall be carefully fitted and securely attached. Apply hardware in


neat, workmanlike manner. Locks shall be tested, knobs tightened, and
necessary adjustments be made to put entire job in good working order.

End of Section 06402

Interior Architectural Woodwork


06402
V.R. Benito Architectural Services

Page 3 / 3

Date 11/06/2009
Rev. Date //

You might also like