You are on page 1of 10

Product Support Group

P.O. Box 368 Herzliya B. 46103 Israel


Tel: 972-9-960-8222
Fax: 972-9-960-8299
www.scitexvision.com

Technical Note
Product

Scitex XLjet

T/N #

11

Subject

Loading the Driver Parameters

Revision
No. pages

10

Refer to T/N #
Written by

Vadim Rudy, Eran Hirschberg

Checked by

Eyal Manzoor

Edited by

Sara Stein

Date

25.11.01

Loading the Driver Parameters

Overview
Loading the motor driver parameters is an integral part of the driver replacement
procedure. The parameters are loaded after installing the new motor driver, or in case
of adjusting the current motor driver parameters.

Required tools
SigmaWin100 software application installed in the Scitex XLjet computer.

Loading the motor driver parameters


1.

Using the machine key, open the Scitex XLjet left cover of the electronic unit.

25/11/01

2/10

Loading the Driver Parameters

2.

Disconnect the Com cable from the Com1 slot in the computers rear side.

Power input socket


Output socket for monitor
PS/2 sockets
(keyboard and mouse)

COM 1
COM 2
(Not used)

Monitor COM
PC Adaptor D-type connector
Network connector

Protection plug

PC Adaptor
SCSI connector
SCSI connector
(not used)
RIP SCSI connector

3.

Connect the JET 110 cable to the Com slot in the computer.

Note: All Scitex XLjet machines are equipped with the JET 110 cable that is not used
for everyday machine operation. The JET 110 cable is only used for testing the
machine driver and the driver parameters set loading.

JET110

25/11/01

3/10

Loading the Driver Parameters

4.

Using the machine key, open the Scitex XLjet right cover of the driver unit.

5.

Connect the other end of the JET 110 cable to the driver as shown in the picture
below.

6.

Close the Scitex XLjet application window.

25/11/01

4/10

Loading the Driver Parameters

7.

Locate the YASAKAWA shortcut icon on the desktop and open the software.

Note: In the first screen that appears you will be prompted to choose an online
connection.

25/11/01

5/10

Loading the Driver Parameters

8.

After you choose an online connection a dialog box will appear, containing
information about the type of hardware that has been detected by the software.
Click OK if this information is correct.

9.

The main software window will appear.

10.

Press the Edit Parameters icon.

25/11/01

6/10

Loading the Driver Parameters

11.

The display of the current parameters set to the specific driver will appear on the
screen.

12.

Insert the Scitex XLjet software backup CD into the computer CD drive.

25/11/01

7/10

Loading the Driver Parameters

13.

Press the Import button.

14.

Browse the CD (SigmaWin Burning files) and locate the Burning files folder.

15.

Choose the relative parameters set.

Note: There are four parameter set files in the Burning files folder. Each file contains
a different set of parameters, according to the specific driver (X, Y, Z, T).

25/11/01

8/10

Loading the Driver Parameters

16.

Check the Select all box to read all the parameters as shown in the picture
below.

17.

Press the Write button to load the parameter set to the driver.

25/11/01

9/10

Loading the Driver Parameters

18.

After writing the new values into the driver, reset the system by turning OFF and
ON the relevant driver circuit breaker.

On

19.

After completing the loading procedure, close the SigmaWin application.

20.

Disconnect both ends of the JET 110 cable from the driver and the computer.

21.

Connect the Com cable to the Com1 connector located in the computers rear
side (see the picture in step 2).

22.

Close the Scitex XLjet left and right covers.

23.

Open the Scitex XLjet application.

24.

The procedure is complete.

25/11/01

10/10

You might also like