12.

In a transistor voltage regulator, the voltage output is


controlled by
zeners and transistors

Report problem
with question
Send your reference
74%

transformers and transistors


diodes and transformers
Flag this
question

Store this question

13. In a undervolt condition in an AC generator system, the


most likely consequence is
activation of the time delay circuit

Report problem
with question
Send your reference
69%

energise the bus tie relay


deactivation of the field regulatory TRs
Flag this
question

Store this question

Report problem
with question
Send your reference
77%

14. Voltage is controlled by


the voltage regulator
the constant speed drive
the swashplate
Flag this
question

Store this question

15. If voltage and frequency of the generator drop to zero in


flight, it would be an indication that the
phase sequence detection circuit has operated
bus tie interlock is inoperative
CSD drive shaft has sheared
Flag this
question

Store this question

Report problem
with question
Send your reference
79%

17. When paralleling two AC generators


it is important that they are in phase, and should be
brought on in sequence ABC
it is important that they are in phase, and can be brought
on in either ABC or CBA

Report problem
with question
Send your reference
67%

they do not need to be in phase


Flag this
question

Store this question

Report problem
with question
Send your reference
50%

19. Trip signals for a GCR are


underfrequency and overcurrent
overfrequency and undervoltage
differential protection and undervoltage
Flag this
question

Store this question

20. Generator brushes spark because


brushes are in-line with the neutral magnetic axis of
generator
brushes are in-line with the neutral geometric axis of
generator

Report problem
with question
Send your reference
40%

of low spring tension


Flag this
question

Store this question

22. A neutralising agent for sulphuric acid is


borax powder
citric acid

Report problem
with question
Send your reference
80%

sodium bicarbonate
Flag this
question

Store this question

23. When checking the specific gravity of the electrolyte in a


battery
only the end cells need be checked as they contain the
terminals
one cell only need be checked as the remainder will read
the same

Report problem
with question
Send your reference
84%

each cell should be checked as the readings may differ


Flag this
question

Store this question

24. What may result if water is added to a nickel-cadmium


battery when it is not fully charged?
The cell temperature will run too low for proper output

Report problem
with question
Send your reference
78%

No adverse results since water may be added anytime


Excessive spewing will occur during the charging cycle
Flag this
question

Store this question

Report problem
with question
Send your reference
62%

25. A GCR will trip if what is detected?


Over current and over frequency
Over frequency and under current
Under frequency and over frequency
Flag this
question

27. In a synchronous motor the rotor is

Store this question

Report problem
with question

Send your reference


46%

self excited
excited by DC
excited by AC
Flag this
question

Store this question

29. A P.M.G (Permanent Magnet Generator) is a small built


in generator which
provides initial excitation

Report problem
with question
Send your reference
79%

only rotates after starting


only rotates during starting
Flag this
question

Store this question

30. In a constant frequency AC system, real load sharing is


achieved by regulating the
voltage regulator
generator speed
generator drive torque
Flag this
question

Store this question

Report problem
with question
Send your reference
42%

You might also like