You are on page 1of 4

Acuvim 300 Series

Three-Phase Intelligent Power Meter

Metering of distribution feeders

ISO9001 Certified

Medium and low voltage systems

Commercial, industrial, utility

OEM Applications

DESCRIPTION
The Acuvim 300 series Three-Phase Intelligent Power Meter is widely used for
monitoring and controlling in distribution systems. This compact meter can
provide true RMS measured values of electric system parameters, such as:
True RMS measuring parameters
Over/Under Limit Alarming
Energy Pulse Output
Individual Harmonics 2nd to 31st
TOU, 4 Tariffs, 12 Seasons, 14 Schedules

300 Series Meter combines high accuracy measurement with intelligent


multifunction capabilities and a simple HMI interface.
The Acuvim 300 may be used as a data acquisition unit for an Intelligent
Power Distribution Automation System or a Plant Automation System that
integrates process, instrument and electrical requirements. All measured
values are available via the RS485 communication port running Modbus
protocol. The Acuvim 300 Series Meter is suitable for AC applications where
there is considerable distortion of current waveforms from nonlinear loads
such as a VVVF Inverter, Ballastor and Switching Power Supply.

The TOU features of the Acuvim 300 meter also include Daylight Savings
Time and a decade holiday setting function. The meter has multiple IO
functions. The 2 Relay Outputs are for Electric Switch controllingor alarming.
2 Digital Outputs are for energy pulse output or alarming. Switch Status
monitoring is possible by using the 4 switch (DI) inputs. Two Analog Outputs
can be used in DCS systems or industrial monitoring equipment. The Acuvim

Acuvim 300 Series Power Meters


Function

Function

Metering

Voltage
V
Current
I
Power
P
Reactive Power
Q
METERING
Apparent Power
S
Power Factor
PF
Frequency
Hz
Energy
Ep
ENERGY
Reactive Energy
Eq
Apparent Energy
Es
Current, Power Demand
Dmd
DEMAND
The Maximum of Current and Power
Dmd
Demand
Energy
TOU
4 tariffs, 12 seasons
Demand
Voltage THD
POWER QUALITY Current THD
Voltage, Current Individual Harmonics
2nd to 31st
Digital Input (additional
DI Option
4DI+1PO
24Vdc Auxiliary Power)
Relay Output or Over/
2RO
Optional RO Under Limit Alarm
I/O OPTION
or DO
Energy Pulse Output or
2DO
Over/Under Limit Alarm
AO Option
Analog Output
2AO
communication RS485, Modbus-RTU protocol
DISPLAY
LCD Display
SIZE
Function

Metering
Voltage
Current
Power
Reactive Power
METERING
Apparent Power
Power Factor
Frequency
Energy
ENERGY
Reactive Energy
Apparent Energy
Voltage THD
POWER QUALITY
Current THD
Relay Output or Over/
Optional RO or Under Limit Alarm
DO
I/O OPTION
Energy Pulse Output or
Over/Under Limit Alarm
AO Option Analog Output
DISPLAY
LCD Display
SIZE

Option Blank NA

Acuvim 361 Acuvim 362 Acuvim 382 Acuvim 387 Acuvim 390 Acuvim 398

969679.5mm
Acuvim 301

Acuvim 302

Acuvim 322

V
I
P
Q
S
PF
Hz
EP
Eq
Es

2 RO
2 DO
2 AO
969679.5mm

Acuvim 327

Acuvim 330

TYPICAL WIRING
LINE
A B C N

LINE
A B C N

1A FUSE

1A FUSE

Terminal Block

Terminal Block

1 I11
2 I12
3 I21
4 I22

1 I11
2 I12
3 I21

Acuvim 300

4 I22

5 I31

5 I31

6 I32

6 I32

1 I11
2 I12
3 I21

Acuvim 300

4 I22

LINE
A N

AO/PO Option
Power
Supply

Comm

35
34
33

N/- L/+

32
21 20 19

27

26

Single Phase 3 Line

RO/DO Option

Acuvim 300

S
S

LOAD

S1 S2

13
24+

14
NC

15
24G

S3

S4

DI Power(24V)

22 23 24 25 26 27
DI1 DI2 C12 DI3 DI4 C34
DI Input

DI Input

DI1

DI2

C12

15

14

13

DI Input

Auxiliary Power

Single Phase 2 Line

6 I32

LOAD

31

DI4 C34

16 17 18

30

25

6 I32

29

Acuvim 300

5 I31

23 24

Acuvim 300

5 I31

4 I22

9 10 11 12
Vn V3 V2 V1

O11 O12 O21 O22

22

4 I22

Power Supply
100~415Vac, 50/60Hz
100~300Vdc
3W

3 I21

Acuvim 300

2LL, 3CT

DI Input

3 I21

9 10 11 12
Vn V3 V2 V1

2 I12

6 I32

DI1 DI2 C12 DI3

2 I12

AO1+ AO1- AO2+ AO2-

28

Terminal Block

1 I11

Vn V3 V2 V1

5 I31

3LN, 3CT

1A FUSE

10 11 12

LOAD

3LN, 3CT with 3CT

1A FUSE

Terminal Block

10 11 12

Vn V3 V2 V1

LOAD

1 I11

1A FUSE

Terminal Block

9 10 11 12
Vn V3 V2 V1

LOAD

LINE
A N B

LINE
A B C

1A FUSE

SPECIFICATIONS
Output

INPUT

Current Inputs
Nominal Current
Withstand
CT Burden
Accuracy

RO Output
5Arms
100Arms for1s
3250Vac rms, 50Hz/60Hz for1minute
<0.2VA
0.001Arms

Type
Contact Resistance
Switching Voltage (Max)
Max Break Current
Configuration
Output Mode

400 L-N/690 L-L Vac rms (+20%)


400 L-N Vac rms
2500Vac/1s
45~65Hz
3250Vac rms, 50~60Hz, 1min
<0.2 VA
2M /phase

Alarm Output

7.5mA
16~30V
4k
2500V

Type
Isolation Voltage
Max Working Voltage
Max Working Current
Pulse Width

Voltage Inputs
Nominal Full Scale
Withstand
Metering Frequency
Withstand
PT
Input Impedance

DI Inputs
Input Current
Input Voltage
Input Resister
Isolation Voltage

COMMUNICATION
Modbus-RTU Protocol
2-wire Connection, Half-Duplex, Isolated
1200 to 38400 baud rate
Power Supply

Operating Temperature
Storage Temperature
Relative Humidity

Type

Voltage, Current, Power, Reactive Power,


Apparent Power, Power Factor, Voltage
Unbalance, Factor, Power Demand,
Frequency, Reactive Power Demand and
Apparent Power Demand (Choose 1 of 18)
RO/DO

DO Output

RS-485 (Option)

Input
Power
Withstand

Alarm Parameters

Mechanical Contact
100m@1A
250Vac, 30Vdc
5A
A
800ms

100~415Vac, 50/60Hz, 100~300Vdc


3W
3250Vac, 50/60Hz, 1min
OPERATING ENVIRONMENT
- 25C to 70C
- 40C to 85C
5% to 95% non-condensing

Photo-MOS normally open contacts


2500Vac rms
100Vdc
50mA
60ms

24Vdc PO
Output Voltage
Power
Isolation Voltage

24V(10%)
2W
1000Vdc

AO Output
Output Range
Accuracy
Load Capacity

0~20mA/4~20mA; 0~5V/1~5V
0.5%
4~20mA Max Load Resister: 500
0~5V Max Current: 20mA

ORDERING INFORMATION

DIMENSIONS

Unit: mm (inches)

AO Mode

AO

RO/DO

NA: None
2RO: 2RO Output
2DO: 2DO Output

96.00 (3.800)

Front View

0DI: No DI
4DI: 4DI+1PO (24Vdc)

0A: No current input


5A: 5A
1A: 1A

Current

50: 50Hz
60: 60Hz

Frequency

53.50 (2.106)
65.00 (2.559)

Side View

Acuvim 361
Acuvim 362
Acuvim 382
Acuvim 387
Acuvim 390
Acuvim 398

92.00 (3.622)

Type

0AO: No AO
1AO: 1AO Output
2AO: 2AO Output

91.00 (3.583)

DI

CUR: Current Type Output (4~20mA/0~20mA)


VOL: Voltage Type Output (0~5V/1~5V)

96.00 (3.800)

Acuvim

Cut Out

Acuvim 300 Series Meter Ordering Example: Acuvim 390 - 60 - 5A - 4DI - 2RO - 1AO - CUR
92.00 (3.622)

Acuvim

Cut Out
AO Mode

AO

RO/DO

Current

Frequency

Type

CUR: Current Type Output (4~20mA/0~20mA)


VOL: Voltage Type Output (0~5V/1~5V)
0AO: No AO
1AO: 1AO Output
2AO: 2AO Output
NA: None
2RO: 2RO Output
2DO: 2DO Output

0A: No current input


5A: 5A
1A: 1A
50: 50Hz
60: 60Hz

Acuvim 301
Acuvim 302
Acuvim 322
Acuvim 327
Acuvim 330

Acuvim 300 Series Meter Ordering Example: Acuvim 330 - 60 - 5A - 2RO - 1AO - CUR

Accuenergy Corp.
Los Angeles-Toronto-Beijing

Revision Date: Aug., 2012

North America Toll Free: 1-877-721-8908


Web: www.accuenergy.com
Email: marketing@accuenergy.com

Document #1080E1105