You are on page 1of 50

IBM TotalStorage

DS4000 series skill transfer

2009 IBM Corporation

IBM TotalStorage

Agenda

DS4000 series hardware introduction


DS4000 troubleshooting
DS4000 hardware maintenance
DS4000 firmware package
DS4000 data collection
DS4000 material

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4000 hardware introduction


Product list

DS4300 (FAStT600)

DS4500/DS4400 (FAStT900/FAStT700)

DS4700

DS4800

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4300 (FAStT600)
Base mode

Up to two 2 Gbps hot swappable RAID controllers with 512 MB of battery backed cache (256
MB per controller).
Support for up to three IBM TotalStorage DS4000 EXP700/EXP710 Expansion Units.
Support for one storage partition in standard configuration. There is an option to expandup to
4, 8, or 16 storage partitions.

Turbo mode

Increased cache from 256 MB per controller on base DS4300 to 1 GB per controller on
Turbo.
Support for up to seven IBM TotalStorage EXP710 Expansion Units. EXP810 Enclosures can
also be used behind the DS4300.
Host interface on base DS4300 is 2 Gbps. Turbo auto senses to connect to 1 Gbps or 2
Gbps.
Eight storage partitions standard, with upgrade to 16 or 64.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4300 (FAStT600)
Green Power LED:

This LED indicates that the DC power status is OK.

Amber General-System-Fault LED:

When a storage server component fails (such as a disk drive,


fan, or power supply), this LED will be on.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4300 (FAStT600)

Host loop LED (green):

There is no data in cache.


The cache option is not selected for the array.
The cache memory has failed, or the battery has failed.

Battery charged LED (green):

Normally, this LED should be on. If it is off, it indicates a battery fault. The LED blinks while the battery is
charging or performing a self-test.

Expansion port bypass LED (amber):

This LED is on when the data is in cache. If it is off, one of the following situations has occurred:

The host loop is down, not turned on, or not connected.


A SFP has failed, or the host port is not occupied.
The RAID controller circuitry has failed, or the RAID controller has no power.

Cache activity LED (green):

This LED should be on, which means that the host connection loop is good. If it is off, the following problems
might have occurred:

The LED will be on if nothing is plugged into the expansion port, or the expansion is powering off.

Expansion loop link LED (green):

Normally on when the drive-side Fibre Channel loop is operating normally.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Host side connection

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Drive side connection

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4500 (FAStT900)
Dual, redundant 2 Gbps RAID controllers with 2 GB of Rambus
cache memory (1 GB per RAID controller). The data in the
cache is protected by battery backup for at least seven days.
Supports connecting up to sixteen EXP100 or EXP710 or up to
fourteen EXP810 enclosures
Has 16 storage partitions standard, with upgrade option to 64.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4500 (FAStT900)

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4500 (FAStT900)

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4500 (FAStT900)
Speed LED (green):

This LED is on when the selected link speed is 2 Gbps and a link is up. This LED
is off when the DS4500 RAID Controller works on 1 Gbps.

Fault LED (amber):

This LED should normally be off. If on it indicates a fault of the mini-hub or one of
the SFP modules.

Two Bypass LEDs (amber):

There is one bypass LED for each SFP module. This LED should normally be off
if no SFP module is installed. But if a SFP module is present, and a link error is
detected (for example, no cable or faulty cable, or host not powered on) it will go
on.

Loop good LED (green):

This LED should be normally on. It might be off if there are link errors.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Host side connection

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Drive side connection


Only one port on each minihub of the DS4500 on the
drive side is ever used. We
recommend removing all the
SFP modules on the minihub ports that are not
connected to any device

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4700
The IBM System Storage DS4700 Express storage server uses 4
Gbps technology
Model 70 contains 2 GB of cache memory (1 GB per controller), four
4 Gbps FC host ports (two ports per controller), and four shortwave
small form-factor pluggable (SFP)
Model 72 contains 4 GB of cache memory (2 GB per controller), eight
4 Gbps FC host ports (four ports per controller), and six shortwave
SFP
Supports up to six EXP810
Both models 70 and 72 have selectable storage partitions up to 128

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4700

Locate LED (white or blue)

On: Indicates storage subsystem locate.


Off: This is the normal status.

Service action allowed LED (blue)

On: The service action can be performed on the


component with no adverse

consequences.

Off: This is the normal status.

Service action required LED (amber)

On: There is a corresponding needs attention


condition flagged by the controller

firmware. Some of these conditions might not be


hardware related.

Off: This is the normal status.

Power LED (green)

On: The subsystem is powered on.


Off: The subsystem is powered off.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4700

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4700

LED #1-2 (green): Host channel speed


LED #3 (blue): Serviced action allowed
LED #4 (amber): Need attention
LED #5 (green): Caching active
LED #8-11 (amber): Drive channel bypass
LED #9-10 (green): Drive channel speed
LED #12 (green/yellow): Numeric display (enclosure
ID/diagnostic display)

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4700
Service action allowed (blue)

Off: Normal status.

On: Safe to remove.

Battery charging (green)

On: Battery charged and ready.

Blinking: Battery is charging.

Off: Battery is faulted, discharged, or missing.

Needs attention or service action required (amber)

Off: Normal status.

On: Controller firmware or hardware requires attention.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4700
Power supply fan LED (AC power) (green)
Off: Power supply fan is not providing AC power.
On: Power supply fan is providing AC power.

Serviced action allowed (blue)


On: Safe to remove.
Off: Normal status.

Needs attention (amber)


Off: Normal status.
On: Power supply fan requires attention.

Power supply fan Direct Current Enabled (DC power) (green)


Off: Power supply fan is not providing DC power.
On: Power supply fan is providing DC power.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Host side connection

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Drive side connection

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4800
The 1825-80A and 1815-82A come with 4 GB of total cache
The 1815-84A has 8 GB of total cache
1815-88A has 16 GB of total cache.
Supports up to 16 EXP710 FC-only enclosures for a total of 224
disks.
Supports up to 14 EXP810 enclosures for a total of 224 disks.
Supports up to 512 host storage partitions.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4800

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4800

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Host side connection

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Drive side connection


The DS4800 supports four redundant drive channel pairs on which to
place expansion enclosures
Ports 4 and 3 on controller A are channel group 1.
Ports 2 and 1 on controller A are channel group 2.
Ports 1 and 2 on controller B are channel group 3.
Ports 3 and 4 on controller B are channel group 4.

The two ports on each drive channel group must run at the same
speed.
.

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Drive side connection


The best sequence (Figure 3-52) to populate drive channel pairs is:

1. Controller A, port 4/controller B, port 1 (drive channel pair 1)

2. Controller A, port 2/controller B, port 3 (drive channel pair 3)

3. Controller A, port 3/controller B, port 2 (drive channel pair 2)

4. Controller A, port 1/controller B, port 4 (drive channel pair 4)

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4000 troubleshooting
Basic tools

Recovery Guru

Major Event Log (MEL)

Other tools

RLS

etc..

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Recovery Guru
If there is an error condition on your DS4000, the Recovery
Guru will explain the cause of the problem and will provide
necessary actions to recover. It will guide you to perform
specific actions, depending on the event

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Major Event Log


The Major Event Log (MEL) is the
primary source for troubleshooting a
DS4000 storage server. To access
the MEL select Advanced
Troubleshooting View Event
Log.
By default only the last 100 critical
events are shown, but you can
choose how many events you want to
have listed. The maximum number
you can set is 8191.
If you want to troubleshoot your
system, use the full event log, as it
includes information about actions
that took place before the actual
critical event happened, thus giving
you the complete history of the
problem.
July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4000 hardware maintenance


Disk replacment
Battery replacement

Remember DO backup(ASD,profile) before normal maintenance
Remember DO data backup before maintenace that maybe
harmful

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4000 disk replacement


Failed drive/Bypassed drive

Check Recovery Guru, verify the problem and recovery method

Replace the drive according to the service guide

Plug out the failed drive (Usually amber LED will be on)
Wait for about 30 sec
Plug in the new drive
Waiting for the reconstruction complete

Impending failure drive

Check Recovery Guru, verify the problem and recovery method

Option 1: waiting for the drive failed

Option 2: Directly replace the drive

July 1, 2007

Un-assign the hot spare


Manually failed the drive
Plug out the failed drive (Usually amber LED will be on)
Wait for about 30 sec
Plug in the new drive
Waiting for the reconstruction complete
Re-assign the hot spare
2009 IBM Corporation

IBM TotalStorage

DS4000 disk replacement


If Multiple drive failed at almost the same timestamp

Collect data and waiting for L2s action plan

If reconstruction failed

Recommend to order another one, if failed again, maybe some


logical error occurred. Collect data for L2 review

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Cache battery replacement


Check the cache setting in Storage Manager
In order to ensure no data in cache, it is
recommended to disable the cache setting
According to the service guide to replace the
cache battery

DS4300 need to offline the controller.

DS4400/DS4500/DS4700 can replace the battery


directly.

DS4800 should ensure Ctrl A is optimal

Waiting for the battery self-test/charge complete


Reset battery age
Reset cache setting

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4000 battery policy


Above FW 6.60, the age of DS4000 cache battery has been
changed to 10 years.
If only battery status is failed, the battery should be replaced.
If battery status is near expiration, recommended to update the
FW to above 6.60. After the upgrade, the warning will be
cleared

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4000 firmware
The firmware pack include the controller firmware, NVSRAM,
ESM code, DDM code
The controller firmware and NVSRAM should be matched
The ESM code and the controller firmware should be matched
Pay attention when the DS4000 is attached with both EXP710
and EXP700/EXP810
Remember always check the firmware package readme file and
the code matching before doing update
All hardware error should be solved before update the firmware
except the JFQ3/JFQ4 issue

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4000 firmware update


The normal process of DS4000 firmware update is:

Update ESM code

Update Controller/NVSRAM code

DDM code update need stop IO on hosts

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Check the DS4000 firmware

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

ESM update

ESM
ESM 5

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Controller firmware update

Controller firmware and NVSRAM


can be updated at the same time
The update takes about 15-20 mins

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DDM dirve update

When updating, the host should


stop IO

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Case scenarios
DS4000 has JFQ3/JFQ4 disks and need to update the firmware
DS4000 has EXP710 attached and need to update the firmware
from 06.12.16.00 to 06.60.08.00
When updating the controller firmware, the SM lost connection
with DS4000

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

DS4000 date collection


All support data
Serial port output

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

All support data


Do connect to both controller with hub when collecting ASD
If hub is not available, collect two ASD from ctrl A and ctrl B
respectively
In order to make the drive link statistic more accurate,
recommend to do 15-30 before collecting ASD

clear allDriveChannels stats;

reset storagesubsystem RLSBaseline;

reset storagesubsystem SOCBaseline;

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

All support data

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Serial port output


Using Putty or serial cable to connect the DS4000
Connection parameter

July 1, 2007

2009 IBM Corporation

IBM TotalStorage
7

Serial port output

Command that should be collect

FW6:

July 1, 2007

loadDebug
moduleList 1
arrayPrintSummary
netCfgShow
inetstatShow
moduleShow
cfgUnitList
vdAll vdShow
ghsList
printBatteryAge
cfgPhyList
hwLogShow
excLogShow
spmShowMaps
spmShow
getObjectGraph_MT 1
getObjectGraph_MT 4
getObjectGraph_MT 8
ccmStateAnalyze 8
fcDevs 1
i
fc 111
ionShow 99
hdd 5
fcAll
socShow
showEnclosures
showEnclosuresPage81
unld ffs:Debug

loadDebug
moduleList 1
evfShowOwnership
cmgrShow
vdmShowDriveList
vdmShowRAIDVolList
vdmDrmShowMgr
vdmShowVGInfo
evfShowAllVols
bmgrShow 15
bidShow 255
tditnall
iditnall
fcnShow
chall
luall
ionShow 12
fcAll 10
showSdStatus
ionShow 99
discreteLineTableShow
ssmShowTree 2
socShow
showEnclosuresPage81
excLogShow
hwLogShow
spmShowMaps
spmShow
fcHosts 3
getObjectGraph_MT 1
getObjectGraph_MT 4
getObjectGraph_MT 8
ccmShowState
netCfgShow
inetstatShow
dqlist
taskInfoAll 3
tpgmShowSummary
unld ffs:Debug

2009 IBM Corporation

IBM TotalStorage

DS4000 material
Redbook
Firmware package

July 1, 2007

2009 IBM Corporation

IBM TotalStorage

Q&A

July 1, 2007