You are on page 1of 60

PIPE CLAMPS, CLAMP BASES,

PIPE CONNECTING PARTS

4
PRODUCT
GROUP

PIPE CONNECTION PARTS

CONTENTS

PAGE

Pipe clamps and clamp bases_______________________________________4.1


Horizontal clamps type 41, 42, 43, 44 _______________________________4.3

Riser clamps type 45, 46, 48 _______________________________________4.4


Clamp bases, type 49______________________________________________4.5
Special designs ___________________________________________________4.7

U-bolts, type 40 __________________________________________________4.8


Selection of weld-on lugs, type 41___________________________________4.9
Weld-on lugs for pipe elbows, type 41 ______________________________4.10

Selection of pipe clamps and clamp bases___________________________4.11


Selection overview OD 0.84 OD 36 _____________________________4.12

PRODUCT
GROUP

Selection overview, temp. 1130 1200F, OD 1.33 OD 36__________4.46


Lift-off restraints for clamp bases, type 49 ___________________________4.54
Connection plates, type 77 ________________________________________4.55

Installation instructions ___________________________________________4.56

6
7
8
9
4.0

PIPE CLAMPS AND CLAMP BASES,


PRODUCT GROUP 4
In high temperature piping
systems, pipe clamps and
clamp bases are the most
highly stressed and therefore most vulnerable components in the support
system, owing to the additional effects of high temperatures. In spite of this,
pipe clamps are seldom
checked, as access is difficult after commissioning
due to the surrounding
insulation.

Standardization
Pipe clamps, clamp bases, pipe weld-on lugs
and U-bolts constitute the group of pipe connection components. Regarding these products, the design criteria for piping systems
lead to a wide variation and hence to a
particularly large number of components.
The dynamic clamps in Product Group 3
(see page 3.19) also belong in principle to
this group. The design of both horizontal
and vertical piping is determined by
diameters
loads
temperature of the medium
For appropriate coverage of the whole spectrum with safe products, LISEGA provides a
complete program of standardized products
for the whole field of application. In line
with the special requirements of the field of
application, the corresponding ideal design
shape has been developed. Diameters range
from OD 0.84 to 36 inch [OD 21.3 to OD
914.4], the temperature range extends to

1200F [650C] and the loads divided into


economical areas of operation cover the
highest level of the practical field of
application.

Fields of application of
standardized pipe clamps

Type 43 - 48 at T = 660F

Type 43 - 48 at T = 1040F

permissible load

kips

Type 46/48

Type 46/48

Type 44/2x

Type 48

Type 44

Type 45

nominal diameter

4.1

Type 44/2x

Type 43 - 48 at T = 1200F

Type 43

Type 44

Type 43

Type 45
Type 43

inch

Type 44

4
These standardized components are an integral part of the LISEGA modular system, so
connection and load compatibility to the load
groups are correspondingly assured.
Quality
Because of their exposed field of application,
the design and construction of the pipe connection components require particular attention. Just as much care should be spent
on the pipe supports as on the piping itself,
since:

Through standardization of the entire application spectrum with sophisticated designs,


plant designers, constructors and operators
can draw equal profit:
Comprehensive and clearly structured
data tables simplify planning work
all supplies from a single source
through integration into a complete
support program
(LISEGA modular system)

Piping can never be better than its supports!

superior quality at competitive prices


through rational series production and
favorable designs

The most important prerequisite for dependable component quality is general standardization.

consistent standardization enables


instant availability

When purchasing pipe connection components, confidence should only be placed in


products of proven suitability.

favorable performance/weight ratios,


easy to install designs and connection
compatibility of LISEGA components
allow rational installation
the uniform design with guaranteed
safety factors ensures maximum
operational safety
a correspondingly compact design
prevents excessive heat loss
certification from type tests by
independent authorities is on hand

4.2

HORIZONTAL CLAMPS WITH CONNECTION PARTS


TYPE 41, 42, 43, 44
1. Weld-on lug type 41
This type is used principally as a pipe connection for piping under 175F [80C] on
horizontal pipes or elbows.

Typ 41

Material: carbon steel

Horizontal clamps with connecting parts 

Type 42 .. .9
Type 43

Type

2. Horizontal clamp type 42


This clamp can be used as a construction
component or hanger clamp in cold piping
systems. For larger pipe diameters the load
range is limited.

Dispensing completely with weldings, the


individual parts are form-fitted with non-welded
connections and bolted together with threaded securing studs.
(Patent-No. DE3817059)

Material: carbon steel

The horizontal clamp type 44 is used where


type 43 reaches its economic limits.
This is essentially the high temperature, large
diameter or high load range.

Heat resistant materials


(Construction component clamp)
Type 42 .. 29 - 16Mo3/A204
Type 42 .. 39 - 13CrMo4-5/A387 Gr.12
Type 42 .. 49 - 10CrMo9-10/A387 Gr.22

Type 42 .. 17

44 .. .1 Type
.2
.3

44 .. .4
.5
.6
.7
.8
.9

4. Horizontal clamp type 44


A rigid yoke takes on the load from a pipesurrounding U-bolt with an inlay plate. From
certain diameters, temperatures or load ranges,
a flat steel strap is used instead of a U-bolt.

3. Horizontal clamp type 43


This hanger clamp corresponds to the traditional shape made from flat steel. Its use is
limited to an economical range up to a unit
weight of approx. 55 lbs [25kg]. Connection
to the load chain is made via connecting pins
and LISEGA eye nut type 60.
Through the temperature dependence, the
load-related application range of the pipe
clamps can be extended over a number of
LISEGA load groups.
For this, the eye nuts are so designed that
at least 3 corresponding screw diameters can
be accommodated.
Material: carbon steel, 16Mo3/A204
13CrMo 4-5, A387 Gr.12
10CrMo9-10, A387 Gr.22
F91(1.4903), A387 Gr.91Cl.II

Connection to the load chain is made via a lug


and LISEGA clevis type 61. The connection lug
is designed to accommodate connection pins
of a number of LISEGA load groups.
Material: carbon steel
16Mo3/A204/A387 Gr.22
13CrMo4-5/A387 Gr.12/Gr.22
21CrMoV5-7
1OCrMo9-1O/A387 Gr.22
F91(1.4903)/A387 Gr.91 Cl.II

Comparison of a LISEGA pipe clamp type 44 with a


clamp of traditional design following the same criteria.
(Load 7200 lbs [32kN], temperature 570F [300C]) 

Type 44 .. 51
.2
.3
.4
.5

pipe clamp with U-bolt Type 44


weight 31 lbs

4.3

pipe clamp Type 43


weight 60 lbs

RISER CLAMPS
TYPE 45, 46, 48
1. Riser clamp type 45
With the riser clamp type 45, the lower
range suited to this design is covered.
Connection to the vertical piping is made via
the shear lugs welded to the pipe. The design
and application of the lugs is the responsibility of the piping manufacturer.
Connection to the load chain is made via
connection pins and LISEGA eye nuts type
60. Up to 3 LISEGA load groups can be
accommodated.
When ordering, the desired span (dimension L)
is to be given.
Material: carbon steel
13CrMo4-5/A387 Gr.12/Gr.22
2. Riser clamp type 46/48
The design of this riser clamp exploits the box
shape as the best precondition for the economical use of material. The individual parts
are bolted together without weldings via
socket connections.
(Patent no. DE3817015)

Material: carbon steel


16Mo3/A204/A387 Gr.22
13CrMo4-5/A387 Gr.12/Gr.22
10CrMo9-10/A387 Gr.22
Only for type 48
F91(1.4903)/A387 Gr.91Cl.II
3. Special designs
For equipping austenitic pipe systems,
all pipe clamps can be fitted with
austenitic inlay plates.

Riser clamp type 45 with


connecting parts

For special diameters not contained in


the selection table, corresponding intermediate sizes are available or, for minimal
diameter differences, appropriate inlay
plates are supplied.
The riser clamp type 48 can quite easily
be supplied as a special design in conjunction with LISEGA rigid struts type 39
as an axial stop for both directions, also
for dynamic loads (see Special Designs
on page 4.7).

Connection to the vertically assembled piping


can be made in two different ways and therefore demands two different designs:

Riser clamp type 46 with


connecting parts

Riser clamp type 48 with


connecting parts

Type 46 for load support through either


4 or 2 shear lugs welded to the pipe.
In general, two lugs come into operation
only at ND  6 inch and are to be so
arranged that they lie laterally to the
longitudinal axis.
Type 48 for load support through
trunnions welded to the pipe.
The bore diameter for the trunnions is
approximately 1/3 of the pipe diameter
based on ASME Code case N-392-3 and
DIN EN 13480-3.
Connection to the load chain is formed by
integrated lugs designed for connection to
LISEGA clevises, type 61.
The connection lugs are designed to accommodate the connection pins for a number of
LISEGA load groups.

 Type 43 with inlay plate  Type 44 with inlay plate

Special design of a riser clamp


type 46

4.4

CLAMP BASE
TYPE 49
Clamp bases are generally used as slide
bearings (loose supports) for horizontally
arranged piping systems.

The fixed installation heights relate, for all


diameters, to the respective lower rim of the
pipe and have a dimension range of 2 or 4
inch [50 or 100mm] increments.

As with pipe clamps, the application spectrum embraces a diameter range of


OD 0.84 to 36 inch [OD 21.3 to OD
914.4mm] and a temperature range up to
1110F [600C].

The standard dimensions selected for the


support height of pipes as well as the length
of the slide bases cover the most common
cases of application.
Different application conditions through
temperature and loading demand different
clamp base designs.

Besides the support load, the operational


temperature of the piping is an essential
design criterion in the design of clamp bases.
The material to be used is determined by
this. The installation height is governed by
the thickness of the heat insulation.

If required, components with special dimensions can be supplied (see also Special
Designs, page 4.7).

To keep within a clear level of available sizes,


fixed installation heights are assigned to the
temperature ranges.
 Clamp base heights dependent on temperature of the medium and pipe diameter.

Possible stress effects on a


clamp base

4.5

Temp. up to

57/8

77/8

660F (350C)

pipe

0.84-3.50

0.84-22

4.25-36

12.75-36

Temp up to

57/8

77/8

97/8

117/8

930F (500C)

pipe

0.84-1.06

1.33-3

3.50-7.625

8.625-18

20-36

Temp. up to

57/8

77/8

97/8

117/8

1040F(560C)

pipe

0.84-3

3.50-6.625

7.625-12.75

14-36

Temp. up to

57/8

77/8

97/8

117/8

1110F(600C)

pipe

0.84-3

3.50-6.625

7.625-12.75

14-36

4
1. Design for lower temperatures and
smaller pipe diameters
The design for this field of application consists
of two shaped halves. On installation with the
piping, the lower section of both halves is
bolted on firmly and provides the slide base.
In the upper section the pipe is secured in
position via a preset screw.
Through the free space under the pipe allowed by the design of the component, constant ventilation of the area is assured.
This is essential for cold piping systems, because otherwise permanent moisture would
develop here after only a short time, causing
corrosion of the piping.
Material: A36

2. Design for medium and high


temperatures
This design consists of a shaped lower metal
part firmly welded to two pipe clamps.
The lower section is fitted, according to the
respective design load, with a reinforcement
gosset.
The clamp bases are versatile in application.
By the use of two lower sections set against
each other, a double guide can easily be produced. By the additional application of lateral
guides, a manifold guiding system can be
provided. The shape of the support plate
permits the simple mounting of lift-off
restraints. The lower section is so designed
that it can be equipped with a stainless steel
plate as a sliding surface for a PTFE bearing.

Material: A36
16Mo3/A204/A387 Gr.22
13CrMo4-5/A387 Gr.12/Gr.22
10CrMo9-10/A387 Gr.22
Applications of clamp bases on trapezes
or PTFE see page 4.5.
3. Special designs
For the support of austenitic piping systems,
all clamp bases can be fitted with
corresponding stainless steel inlay plates.

Clamp base for smaller pipe


diameters type 49 .. .1, 49 .. .2

Special lengths or heights are possible


if required. In cases of great expansion
it might be more expedient to arrange
for correspondingly long support surfaces
on site.
The slide bearings of all clamp bases
can be supplied as sliding surfaces for
a PTFE or graphite bearing.
For special diameters not contained in the
selection table, corresponding intermediate
sizes are supplied. For minimal diameter
differences suitable inlay plates are
provided.

Clamp base for medium and high


temperatures type 49 .. .3,
.. .4, .. .5

The clamp bases can if required be fitted


with lift-off restraints.
Two-fold or manifold guidings using
standard clamp bases can be supplied
if required (see Special Designs on
page 4.7).

Clamp base type 49 with PTFE


slide bearing to standard design.

 Clamp base with lift-off


restraints, permissible loads and
dimensions, see page 4.54 (Fig. 1)
 Clamp base as double guide
(horizontal application) (Fig. 2)
 Clamp base as manifold guide
(vertical application) (Fig. 3)

(Fig. 1)

(Fig. 2)

(Fig. 3)

4.6

SPECIAL DESIGNS

The use of standard components in the field of pipe


supports has long since
proven its superiority, leading to enormous savings
in time and costs associated with engineering, delivery and installation.
This especially includes
pipe clamps and clamp
bases.
However, because of an
extremely wide range of
applications and the
complexity of piping, in
some cases special designs
are required. In such
situations it is important to
have experts on hand to
ensure tried and tested
solutions and to profit from
proven calculation procedures.

Special designs
Although the standardized LISEGA range of
pipe surrounding support components is
comprehensive and covers all common areas
of application, more complicated cases
sometimes arise where only a special solution can solve the problem.
Among other cases, special designs are most
often required especially for the following
specific applications:
exceptionally restricted areas
interferences insurmountable
by common techniques
tailor-made fixed point designs
exceptionally high load requirements
especially high temperatures
(up to 1800F)
abnormal insulation thicknesses
irregularly inclining pipes
special trunnion diameters
LISEGAs customers are not left on their own
in this regard. For such particular assignments
an experienced team of technicians and
engineers is available, ready to react speedily
and flexibly with appropriate solutions. They
are supported by a kit of special tools such
as modern CAD programs and individual inhouse calculation software. In addition to
this, a broad repertoire of well proven basic
designs is on hand.
Every problem has a solution this conviction motivates LISEGAs experts in support
technology. For our clients this can be
demonstrated as required at any time!

4.7

U-BOLTS
TYPE 40

U-bolts
type 40 01 .8 to 40 91 .8

OD

Type 40 serves mainly to


secure piping of max. 175F
[80C] temp. to secondary
steel structure.

Type
40 01 .8
40 02 .8
40 03 .8
40 04 .8
40 05 .8
40 06 .8
40 07 .8
40 09 .8
40 10 .8
40 11 .8
40 14 .8
40 17 .8
40 22 .8
40 27 .8
40 32 .8
40 36 .8
40 41 .8
40 46 .8
40 51 .8
40 61 .8
40 71 .8
40 76 .8
40 91 .8

OD
0.84
1.06
1.33
1.67
1.90
2.37
2.87
3.50
4.25
4.50
5.50
6.63
8.63
10.75
12.75
14
16
18
20
24
28
30
36

5. digit:

A
1 3/16
1 3/8
1 5/8
2 1/16
2 3/8
213/16
3 7/16
4 1/16
4 7/8
5 1/16
6 1/8
7 3/8
9 3/8
11 5/8
13 3/4
15
17
19 1/8
21 1/8
25 1/8
29 1/8
31 1/8
37 1/8

B
2 3/4
2 3/4
2 3/4
2 7/8
3
3 1/4
3 3/4
4
4 1/2
4 1/2
5
6 1/8
7 1/8
8 3/8
9 5/8
10 1/4
11 1/4
12 5/8
13 5/8
15 5/8
17 5/8
18 5/8
21 5/8

d2 x L
1/ UNC x 23/
4
8
1/ UNC x 23/
4
8
1/ UNC x 23/
4
8
3/ UNC x 23/
8
8
3/ UNC x 21/
8
2
3/ UNC x 21/
8
2
1/ UNC x 3
2
1/ UNC x 3
2
1/ UNC x 3
2
1/ UNC x 3
2
1/ UNC x 3
2
5/ UNC x 33/
8
4
5/ UNC x 33/
8
4
3/ UNC x 4
4
7/ UNC x 41/
8
4
7/ UNC x 41/
8
4
7/ UNC x 41/
8
4
1 UNC x 43/4
1 UNC x 43/4
1 UNC x 43/4
1 UNC x 43/4
1 UNC x 43/4
1 UNC x 43/4

1
1
1
2
2
2
3
4
5
6
7
8
9
10
12
14
15
18

7/
16
1/
2
11/
16
13/
16
15/
16
1/
8
3/
8
3/
4
1/
8
1/
4
3/
4
3/
8
3/
8
3/
8
3/
8

weight
(lbs)
0.12
0.13
0.13
0.35
0.37
0.40
0.85
0.92
1.00
1.03
1.15
2.18
2.54
4.44
5.05
5.38
5.91
12.10
13.10
15.00
16.90
17.90
20.70

2 = carbon steel
4 = stainless steel 1.4301

4.8

WELD-ON LUGS FOR PIPES


TYPE 41
Weld-on lugs for pipes
Type 41 D9 11 to 41 79 12

OD

 Permissible load at 175F


[80C] = normal load (load
case A) of the corresponding load group (3rd digit
of the type designation,
see Max. permissible load
for static components,
page 0.5)
Stress present in the given
welding seam  7.25 ksi
[50N/mm2] at 4 load
angle.
Material: carbon steel
Type 41 .. 11 Smax = 3/8 inch
Type 41 .. 12 Smax = 4 inch

Reduction factors of the


permiss. load at increased
temperatures:

Order details:
Weld-on lug for pipes,
type 41 .9 1.

4.9

Type

d3

41 D9 11
41 D9 12
41 29 11
41 29 12
41 39 11
41 39 12
41 49 11
41 49 12
41 59 11
41 59 12
41 69 11
41 69 12
41 79 11
41 79 12

1 1/4
1 1/4
1 1/2
2 5/8
1 7/8
2 7/8
3 1/8
4 3/4
3 3/8
5 1/4
4 3/4
6 1/2
6 3/4
9

0.41
0.41
0.50
0.50
0.65
0.65
0.81
0.81
1.00
1.00
1.34
1.34
1.60
1.60

1
4 1/2
1
4 1/2
1 1/8
4 3/4
1 5/8
4 7/8
1 5/8
5 1/8
2
5 1/2
2 3/8
5 7/8

F perm. (T)

480F [250C]
660F [350C]

0.7 F perm. (175F)


0.5 F perm. (175F)

1
1
1
1
1
1
2
2

5/
8
5/
8
3/
4
3/
4
7/
8
7/
8
1/
8
1/
8
1/
4
1/
4
5/
8
5/
8

C
5/
8
5/
8
7/
8
7/
8
1/
8
1/
8
1/
2
1/
2
5/
8
5/
8

1
1
1
1
1
1
2
2
2 5/8
2 5/8

G
3/
8
3/
8
3/
8
3/
8
3/
8
3/
8
3/
8
3/
8
3/
8
3/
8
3/
8
3/
8
3/
8
3/
8

a
leg length

t
5/

16

3/

16

5/

16

3/

16

3/

3/

16

3/

3/

16

1/

1/

1/

1/

5/

1/

5/

1/

3/

5/

16

3/

5/

16

3/

3/

3/

3/

1
1
1 1/ 4
1 1/ 4

weight
(lbs)
0.14
0.50
0.24
1.08
0.46
1.66
1.16
3.52
1.66
5.10
3.52
9.10
7.10
16.10

WELD-ON LUGS FOR PIPES


TYPE 41

Permissible load at 175F [80C] is normal


load (load case A) of the highest of the load
groups indicated (see Max. permissible

OD
2.37
2.87
3
3.5
3.5
4.25
4.25
4.5
4.5
5.25
5.25
5.5
5.5
6.25
6.25
6.63
6.63
7.63
7.63
8.63
8.63
9.63
9.63
10.5
10.5
10.75
10.75
12.75
12.75
14
14
14.5
14.5
16
16
16.5
16.5
18
18
20
20
22
22
24
24
26
26
28
28
30
30

Load 
group C
7/
C-2
8
7/
C-2
8
7/
C-2
8
7/
C-2
8
2-3 1 1/8
7/
C-2
8
1
2-3 1 /8
7/
C-2
8
2-3 1 1/8
7/
C-2
8
1
2-3 1 /8
7/
C-2
8
3-4 1 1/2
7/
C-2
8
1
3-4 1 /2
2-3 1 1/8
4-5 1 5/8
2-3 1 1/8
4-5 1 5/8
2-3 1 1/8
4-5 1 5/8
2-3 1 1/8
4-5 1 5/8
2-3 1 1/8
4-5 1 5/8
2-3 1 1/8
4-5 1 5/8
3-4 1 1/2
5-6 2
3-4 1 1/2
5-6 2
3-4 1 1/2
5-6 2
3-4 1 1/2
5-6 2
3-4 1 1/2
5-6 2
4-5 1 5/8
6-7 2 5/8
4-5 1 5/8
6-7 2 5/8
4-5 1 5/8
6-7 2 5/8
4-5 1 5/8
6-7 2 5/8
4-5 1 5/8
6-7 2 5/8
4-5 1 5/8
6-7 2 5/8
4-5 1 5/8
6-7 2 5/8

R1

1
1
1
1
1
1
1

3/
4
3/
4
3/
4
3/
4
7/
8
3/
4
7/
8
3/
4
7/
8
3/
4
7/
8
3/
4
1/
8
3/
4
1/
8
7/
8
1/
4
7/
8
1/
4
7/
8
1/
4
7/
8
1/
4
7/
8
1/
4
7/
8
1/
4
1/
8
5/
8
1/
8
5/
8
1/
8
5/
8
1/
8
5/
8
1/
8
5/
8
1/
4

t
5/
16
5/
16
5/
16
5/
16
3/
8
5/
16
3/
8
5/
16
3/
8
5/
16
3/
8
5/
16
5/
8
5/
16
5/
8
3/
8
3/
4
3/
8
3/
4
3/
8
3/
4
3/
8
3/
4
3/
8
3/
4
3/
8
3/
4
5/
8
3/
4
5/
8
3/
4
5/
8
3/
4
5/
8
3/
4
5/
8
3/
4
3/
4

1
1
1
1
1
1
1
1
1
1
1
1
1
2
1 1/4 3/4
1
2
1 1/4 3/4
1
2
1 1/4 3/4
1
2
1 1/4 3/4
2 1
1 1/4 3/4
1
2
1 1/4 3/4
1
2

loads for static components, page 0.5).


Stress present in the given welding seam
 7.25 ksi [50N/mm2] at 4 load angle.

d3
0.50
0.50
0.50
0.50
0.65
0.50
0.65
0.50
0.65
0.50
0.65
0.50
0.81
0.50
0.81
0.65
1.00
0.65
1.00
0.65
1.00
0.65
1.00
0.65
1.00
0.65
1.00
0.81
1.34
0.81
1.34
0.81
1.34
0.81
1.34
0.81
1.34
1.00
1.60
1.00
1.60
1.00
1.60
1.00
1.60
1.00
1.60
1.00
1.60
1.00
1.60

Weld-on lugs for pipes


(R1.5 OD)
type 41 06 13
up to 41 76 16

R1
a

OD

smax = 4 inch[100mm]
weight
a
Type
E leg length
(lbs)
3/
0.92
41 06 15 5 3/8
16
3/
0.9
41 07 15 5 3/8
16
3/
0.9
41 08 15 5 3/8
16
3/
0.9
41 09 15 5 3/8
16
1/
1.46
41 09 16 5 1/2
4
3/
0.94
41 10 15 5 3/8
16
1
1/
1.52
41 10 16 5 /2
4
3/
0.92
41 11 15 5 3/8
16
1/
1.46
41 11 16 5 1/2
4
3/
0.98
41 13 15 5 3/8
16
1/
1.52
41 13 16 5 1/2
4
3/
0.94
41 14 15 5 3/8
16
1/
3.6
41 14 16 5 3/4
4
3/
0.98
41 16 15 5 3/8
16
1/
3.8
41 16 16 5 3/4
4
1
1/
5
/
1.5
41 17 15
2
4
5/
4.6
41 17 16 5 7/8
16
1/
1.54
41 19 15 5 3/8
4
5/
4.8
41 19 16 5 3/4
16
3
1/
5
/
1.52
41 22 15
8
4
5/
4.8
41 22 16 5 3/4
16
1/
1.56
41 24 15 5 1/8
4
5/
4.8
41 24 16 5 3/4
16
7
1/
4
/
1.56
41 26 15
8
4
5/
4.8
41 26 16 5 1/2
16
1/
1.54
41 27 15 5 1/8
4
5/
4.8
41 27 16 5 3/4
16
1
1/
5
/
3.6
41 32 15
8
4
3/
7.2
41 32 16 5 3/4
8
1/
3.8
41 36 15 4 1/2
4
3/
7.2
41 36 16 4 7/8
8
1/
3.8
41 37 15 4 3/4
4
3/
7.2
41 37 16 5 1/8
8
1/
3.8
41 41 15 4 1/8
4
3/
7.2
41 41 16 4 1/2
8
1/
3.8
41 42 15 4 1/2
4
3/
7.2
41 42 16 4 7/8
8
5/
4.8
41 46 15 3 7/8
16
3/
14.8
41 46 16 4 3/4
8
5/
5
41 51 15 3 3/4
16
3/
14.8
41 51 16 4 3/8
8
5/
5
41 56 15 3 3/8
16
1
3/
14.8
41 56 16 4 /8
8
5/
5
41 61 15 3 1/8
16
3/
14.6
41 61 16 3 3/4
8
5/
5
41 66 15 2 3/4
16
3
3/
14.6
41 66 16 3 /8
8
5/
5
41 71 15 2 3/8
16
3/
14.6
41 71 16 3 1/8
8
5/
5
41 76 15 2
16
3
3/
14.6
41 76 16 2 /4
8

41 .. 13
14
15
16

678678

smax = 1/2 inch[10mm]


weight
a
Type
E leg length
(lbs)
3/
0.26
41 06 13 1 3/8
16
3/
0.24
41 07 13 1 1/8
16
3/
0.24
41 08 13 1 3/8
16
3/
0.24
41 09 13 1 1/8
16
3/
0.46
41 09 14 1 3/8
16
3/
0.24
41 10 13 1 1/8
16
3/
0.46
41 10 14 1 3/8
16
3/
0.24
41 11 13 1 1/8
16
3/
0.46
41 11 14 1 3/8
16
3/
0.24
41 13 13 1
16
3/
0.46
41 13 14 1 1/8
16
3/
0.24
41 14 13 1
16
1/
1.24
41 14 14 1 5/8
4
3/
0.24
41 16 13 1
16
1/
1.26
41 16 14 1 5/8
4
3/
0.44
41 17 13 1
16
5/
1.72
41 17 14 1 5/8
16
3/
0.46
41 19 13 3/4
16
5/
1.74
41 19 14 1 3/8
16
3/
0.44
41 22 13 3/4
16
5/
1.7
41 22 14 1 3/8
16
3/
0.44
41 24 13 5/8
16
5/
1.72
41 24 14 1 1/8
16
3
3/
/
0.46
41 26 13
8
16
5/
1.72
41 26 14 1
16
3/
0.44
41 27 13 5/8
16
5/
1.68
41 27 14 1
16
1/
1.2
41 32 13 5/8
4
3/
2.6
41 32 14 1
8
1/
1.22
41 36 13 - 3/8
4
3/
2.6
41 36 14 1/4
8
1/
0
1.22
41 37 13
4
3/
2.6
41 37 14 5/8
8
1/
1.22
41 41 13 - 5/8
4
3/
2.6
41 41 14 - 1/4
8
3
1/
/
1.22
41 42 13
8
4
3/
2.6
41 42 14 1/4
8
5/
1.7
41 46 13 - 3/4
16
3/
6.8
41 46 14 0
8
5/
1.7
41 51 13 -1 1/8
16
3/
6.8
41 51 14 - 3/8
8
5/
1.68
41 56 13 -1 5/8
16
3/
6.6
41 56 14 - 3/4
8
3
5/
-1
/
1.68
41 61 13
4
16
3/
6.6
41 61 14 -1 1/8
8
5/
1.68
41 66 13 -2 1/8
16
3/
6.6
41 66 14 -1 3/8
8
5/
1
-2
/
1.68
41 71 13
2
16
3/
6.4
41 71 14 -1 3/4
8
5/
1.68
41 76 13 -3
16
3/
6.4
41 76 14 -2 1/8
8

smax
=1/2 inch
smax
=4 inch

Reduction factors of the


permiss. load at increased
temperatures:
T

F perm. (T)

480F [250C] 0.7 F perm. (175F)


660F [350C] 0.5 F perm. (175F)

Order details:
Weld-on lugs for pipes
R1.5 OD
type 41 .. 1.

4.10

SELECTION OF PIPE CLAMPS


AND CLAMP BASES
The selection tables on the following pages
offer a general view of the fields of application. They have been arranged in ascending
order according to pipe diameters. All pipe
clamps and clamp bases to be considered for
a given design of pipe system can therefore
be found clearly set out on one page.
The following points are important for application purposes:
1. In the selection table, all the information
can be found that is required for determining
the correct component and placing an order
free of uncertainty.
2. The component with the lowest permissible
load to cover in the appropriate temperature
range is at the same time the most economical of all those listed.
3. The geometrical values of the connections
are compatible with those of LISEGA connection components. Via the wide load application range, connections in various LISEGA
load groups can be linked up.
4. The lengths of connection lugs are so designed that the connection points lie outside
the economical insulation thicknesses.
5. For use in pipe systems made of austenitic
material, all pipe clamps and clamp bases can
be equipped with corresponding inlay plates.
6. In selecting an appropriate pipe clamp, the
following procedure should be followed:
6.1 Determination of the correct page for the
external dimensions (OD) of the piping to be
supported.
6.2 Determination of the correct temperature
range in the column for the desired support
type, horizontal or vertical.
6.3 Determination of the permissible load to
be covered.
By coupling two pipe clamps with
type 77 (see page 4.55), the loads
can be doubled

4.11

6.4 Checking of the installation dimension


E and width B for agreement with the
installation conditions prevailing.

6.5 For riser clamps, checking of the span


(L-dimension).
6.6 For riser clamps of Type 46/48, the decision as to whether shear lugs or trunnions
should be used.
6.7 On the basis of the properly fitting LISEGA
load group ranges provided, the conformity
of the connection with the load chain required can be ascertained.
6.8 Determination of the selected component
through specification of the appropriate
LISEGA type designation.
7.0 In selecting a suitable clamp base, proceed according to points 6.1 6.3.
In addition, attention should be paid to the
choice of the correct height (dimension H)
which is determined by the thickness of the
heat insulation.
7.1 The heights given (dimension H) as well
as the lengths (dimension A) are standard
dimensions and cover the most common
application cases. If required, components
of different dimensions can be supplied.
8. The supply of pipe clamps and clamp bases
is possible as special designs for particular
uses and conditions (see pages 4.4 and 4.6
in this regard).
9. In the design and construction of LISEGA
pipe clamps and clamp bases, nuclear applications have also been considered.
However, separate fabrication is required in
this case with strict adherence to the LISEGA
quality management system. The type designation hereby differs in the 5th digit by addition of a 5 (see also page 0.7 in this respect).

SELECTION TABLE
OD 0.84- 21.3mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 0.84 (ND 15/1/2), types 42, 43, 45, 49
permissible load (lbs x 1000)
210 480 660 840 930 950 985 1040 1075 1110F d4
Type
0.41
42 01 17 0.56

permissible load (lbs x 1000)


Type
210 480 660 840 930
42 01 19 1.20 0.85 0.65

950

985 1040 1075 1110F

A B
13/4 1

lbs
0.3

load
group
C-D

d2
E
B
0.40 11/8 11/4

lbs
0.7

load
group
C-2

d1
0.48
0.48
0.48

4
51/4
51/4

B
11/4
11/4
11/8

lbs
1.1
1.3
1.3

load
group
C-2
C-2
C-2

E
1
1
1
1
1
1
1
1
1

B
2
2
2
2
2
23/4
23/4
23/4
23/4

load
lbs group
L
4.4 C-4
10
113/4 5.1 C-4
153/4 6.6 C-4
193/4 7.9 C-4
231/2 9.3 C-4
113/4 8.6 C-4
153/4 11.0 C-4
193/4 13.4 C-4
231/2 15.9 C-4

E
7/

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F
43 01 19 1.30 1.00 0.65
43 01 39
1.30 1.15 0.75 0.65 0.45 0.25
43 01 49
0.54 0.40
0.29

Type
45 01 11
45 01 11
45 01 11
45 01 11
45 01 11
45 01 31
45 01 31
45 01 31
45 01 31

permissible load (lbs x 1000)


210 480 660 840 930 950
0.95 0.80 0.55
0.80 0.65 0.45
0.60 0.45 0.30
0.45 0.35 0.25
0.40 0.30 0.20
1.75 1.60 1.05 0.90
1.30 1.20 0.80 0.65
1.05 0.95 0.60 0.55
0.85 0.75 0.50 0.40

985 1040 1075 1110F

0.65
0.45
0.35
0.30

0.35
0.25
0.20
0.15

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F
49 01 11 0.25 0.18 0.13
49 01 12 0.35 0.25 0.20
49 01 25
0.22 0.20 0.13
49 01 35
0.50 0.36 0.31 0.22 0.13
49 01 45
0.27 0.20 0.13

d1
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48

E
23/8
43/8
43/8
61/4
61/4

A
4
6
63/4
63/4
63/4

B
11/2
21/2
21/2
31/2
31/2

C
9
9
9

H
2
4
4
57/8
57/8

lbs
1.3
2.9
4.5
6.6
6.6

4.12

SELECTION TABLE
OD 1.06- 26.9mm

Temperature up to
1200F see page 4.46

Pipe clamps, clamp bases, OD 1.06 (ND 20/ 3/4), types 42, 43, 45, 49

Twice the specified load is possible


by use of type 77 (see page 4.55)

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F d4 E
42 02 17 0.56
0.41 1

permissible load (lbs x 1000)


Type
210 480 660 840 930
42 02 19 1.20 0.85 0.65

950

985 1040 1075

1110F

A B
17/8 1

E
d2
0.40 11/4

B
11/4

lbs
0.3

load
group
C-D

lbs
0.7

load
group
C-2

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


E
Type
210 480 660 840 930 950 985 1040 1075 1110F d1
43 02 19 1.30 1.00 0.65
0.48 43/8
43 02 39
1.30 1.15 0.75 0.65 0.45 0.25
0.48 51/4
43 02 49
0.54 0.40 0.29 0.48 51/4

Type
45 02 11
45 02 11
45 02 11
45 02 11
45 02 11
45 02 31
45 02 31
45 02 31
45 02 31

permissible load (lbs x 1000)


210 480 660 840 930 950
1.00 0.80 0.55
0.80 0.65 0.45
0.60 0.45 0.35
0.45 0.35 0.25
0.40 0.30 0.20
1.80 1.65 1.10 0.95
1.35 1.20 0.80 0.70
1.05 0.95 0.65 0.55
0.85 0.80 0.50 0.45

985 1040 1075 1110F d1


0.48
0.48
0.48
0.48
0.48
0.65 0.35
0.48
0.50 0.25
0.48
0.40 0.20
0.48
0.30 0.15
0.48

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F
49 02 11 0.25 0.18 0.13
49 02 12 0.35 0.25 0.20
49 02 25
0.22 0.20 0.13
49 02 35
0.50 0.36 0.31 0.22 0.13
49 02 45
0.27 0.20 0.13

4.13

E
21/2
41/2
41/2
61/2
61/2

E
1
1
1
1
1
1
1
1
1

A
4
6
63/4
63/4
63/4

B
2
2
2
2
2
23/4
23/4
23/4
23/4

B
11/2
21/2
21/2
31/2
31/2

load
group
C-2
C-2
C-2

B
11/4
11/4
11/8

lbs
1.1
1.3
1.4

L
10
113/4
153/4
193/4
231/2
113/4
153/4
193/4
231/2

load
lbs group
4.4 C-4
5.1 C-4
6.6 C-4
7.9 C-4
9.3 C-4
8.6 C-4
11.0 C-4
13.4 C-4
15.9 C-4

C
9
9
9

H
2
4
4
57/8
57/8

lbs
1.3
3.1
4.7
6.9
6.9

SELECTION TABLE
OD 1.33- 33.7mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 1.33 (ND 25/1), types 42, 43, 45, 49

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F d4 E
Type
0.41 11/4
42 03 17 0.56

permissible load (lbs x 1000)


Type
210 480 660 840 930
42 03 19 1.20 0.85 0.65

950

985 1040 1075 1110F

A B
21/8 1

lbs
0.4

load
group
C-D

E
d2
B
0.40 11/2 11/4

lbs
0.9

load
group
C-2

B
11/4
11/4
15/8

lbs
1.3
1.8
2.3

load
group
C-2
C-2
C-2

L
10
113/4
153/4
193/4
231/2
113/4
113/4
153/4
153/4
193/4
193/4
231/2
231/2

lbs
5.3
6.2
7.7
9.5
11.0
8.6
22.3
11.0
28.5
13.4
34.5
16.0
41.0

load
group
C-4
C-4
C-4
C-4
C-4
C-4
C-4
C-4
C-4
C-4
C-4
C-4
C-4

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F
43 03 19 1.30 1.00 0.65
43 03 39
1.30 1.15 0.75 0.65 0.45 0.25
43 03 49
0.63 0.47 0.36

Type
45 03 11
45 03 11
45 03 11
45 03 11
45 03 11
45 03 31
45 03 32
45 03 31
45 03 32
45 03 31
45 03 32
45 03 31
45 03 32

permissible load (lbs x 1000)


210 480 660 840 930 950
1.30 1.00 0.70
1.05 0.85 0.60
0.75 0.60 0.40
0.55 0.45 0.30
0.45 0.40 0.25
1.90 1.70 1.10 1.00
2.15 1.80 1.75 1.70
1.35 1.25 0.80 0.70
2.15 1.80 1.75 1.70
1.10 1.95 0.65 0.55
2.15 1.80 1.75 1.70
0.85 0.80 0.50 0.45
2.15 1.80 1.75 1.70

985 1040 1075 1110F

0.70
1.70
0.50
1.70
0.40
1.70
0.30
1.70

0.35
1.65
0.25
1.45
0.20
1.10
0.15
0.90

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F
49 03 11 0.25 0.18 0.13
49 03 12 0.35 0.25 0.20
49 03 25
0.27 0.22 0.16
49 03 35
0.60 0.45 0.36 0.27 0.16
49 03 45
0.31 0.25 0.16

d1
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48

E
25/8
45/8
65/8
65/8
65/8

E
d1
0.48 43/4
0.48 61/2
0.48 61/2

E
1
1
1
1
1
1
1
1
1
1
1
1
1

A
4
6
63/4
63/4
63/4

B
23/8
23/8
23/8
23/8
23/8
23/4
31/2
23/4
31/2
23/4
31/2
23/4
31/2

B
13/4
23/4
4
4
4

C
9
9
9

H
2
4
57/8
57/8
57/8

lbs
1.5
3.3
7.7
7.7
7.7

4.14

SELECTION TABLE
OD 1.67- 42.4mm

Temperature up to
1200F see page 4.46

Pipe clamps, clamp bases, OD 1.67 (ND 32/11/4), types 42, 43, 45, 49

Twice the specified load is possible


by use of type 77 (see page 4.55)

permissible load (lbs x 1000)


Type
A B
210 480 660 840 930 950 985 1040 1075 1110F d4
E
42 04 17 0.56
0.41 13/4 25/8 1

permissible load (lbs x 1000)


210 480 660 840 930 950
42 04 19 1.20 0.85 0.65
Type

985 1040 1075 1110F

d2
0.40

lbs
0.4

load
group
C-D

E
B lbs
15/8 11/4 0.9

load
group
C-2

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
43 04 19 1.30 1.00 0.65
43 04 39
1.30 1.15 0.75 0.65 0.45 0.25
43 04 49
0.63 0.47 0.36
Type

Type
45 04 11
45 04 11
45 04 11
45 04 11
45 04 39
45 04 31
45 04 32
45 04 39
45 04 31
45 04 32
45 04 39
45 04 31
45 04 32
45 04 39
45 04 31
45 04 32

210
2.00
1.45
1.10
0.90

permissible load (lbs x 1000)


480 660 840 930 950 985
1.60 1.10
1.15 0.80
0.85 0.65
0.70 0.50
1.12
3.35 2.90 2.20 1.95 1.35
4.90 4.25 4.00 4.00 3.35
1.12 1.06
2.45 2.20 1.65 1.45 1.05
4.90 4.25 4.00 3.55 2.65
1.12 0.85
2.05 1.85 1.30 1.15 0.85
4.90 4.25 3.35 2.90 2.15
1.12 0.98 0.70
1.75 1.55 1.10 0.95 0.65
4.25 3.80 2.65 2.45 1.75

1040 1075 1110F

0.75
0.75
1.95
0.55
0.55
1.45
0.45
0.45
1.15
0.35
0.35
0.95

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
49 04 11 0.25 0.18 0.13
49 04 12 0.35 0.25 0.20
49 04 25
0.27 0.22 0.16
49 04 35
0.60 0.45 0.36 0.27 0.16
49 04 45
0.31 0.25 0.16
Type

4.15

d1
0.48
0.48
0.48
0.48
0.48
0.63
0.63
0.48
0.63
0.63
0.48
0.63
0.63
0.48
0.63
0.63

E
23/4
43/4
63/4
63/4
63/4

d1
0.48
0.48
0.48

E
1
1
1
1
1
11/8
11/8
1
11/8
11/8
1
11/8
11/8
1
11/8
11/8

A
4
6
63/4
63/4
63/4

E
B
51/4 11/4
71/8 11/4
71/8 15/8

B
23/4
23/4
23/4
23/4
23/4
23/4
4
23/4
23/4
4
23/4
23/4
4
23/4
23/4
4

B
13/4
23/4
4
4
4

L
113/4
153/4
193/4
231/2
133/4
133/4
133/4
173/4
173/4
173/4
213/4
213/4
213/4
251/2
251/2
251/2

C
9
9
9

lbs
1.5
2.0
2.5

load
group
C-2
C-2
C-2

lbs
9
12
14
17
16
16
29
19
19
36
23
23
43
27
27
50

load
group
C-4
C-4
C-4
C-4
C-D
1-4
1-4
C-D
1-4
1-4
C-D
1-4
1-4
C-D
1-4
1-4

H
2
4
57/8
57/8
57/8

lbs
1.5
3.5
7.8
7.8
7.8

SELECTION TABLE
OD 1.90- 48.3mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 1.90 (ND 40/11/2), types 42, 43, 45, 49

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F d4 E
Type
0.41 21/8
42 05 17 0.56

permissible load (lbs x 1000)


210 480 660 840 930
42 05 19 1.20 0.85 0.65
Type

950

985 1040 1075 1110F

lbs
0.6

load
group
C-D

E
13/4

B lbs
11/4 0.9

load
group
C-2

d1
0.48
0.48
0.48

E
51/2
71/4
71/4

B
11/4
11/4
15/8

lbs
1.5
2.0
2.6

load
group
C-2
C-2
C-2

B
31/8
31/8
31/8
31/8
31/8
31/8
43/4
31/8
31/8
43/4
31/8
31/8
43/4
31/8
31/8
43/4

L
113/4
153/4
193/4
231/2
133/4
133/4
133/4
173/4
173/4
173/4
213/4
213/4
213/4
251/2
251/2
251/2

lbs
11
13
16
19
18
18
35
22
22
45
26
26
52
31
31
60

load
group
C-4
C-4
C-4
C-4
C-D
1-4
1-4
C-D
1-4
1-4
C-D
1-4
1-4
C-D
1-4
1-4

d2
0.40

A
3

B
1

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
43 05 19 1.30 1.00 0.65
43 05 39
1.30 1.15 0.75 0.65 0.45 0.25
43 05 49
0.63 0.47 0.36
Type

Type
45 05 11
45 05 11
45 05 11
45 05 11
45 05 39
45 05 31
45 05 32
45 05 39
45 05 31
45 05 32
45 05 39
45 05 31
45 05 32
45 05 39
45 05 31
45 05 32

permissible load (lbs x 1000)


210 480 660 840 930 950 985
2.40 1.80 1.30
1.70 1.30 0.90
1.30 1.00 0.70
1.10 0.80 0.60
1.12
4.00 3.55 2.45 2.20 1.60
4.90 4.25 4.00 4.00 4.00
1.12
2.90 2.65 1.95 1.70 1.20
4.90 4.25 4.00 4.00 3.10
1.12 0.98
2.20 2.20 1.55 1.35 0.95
4.90 4.25 4.00 3.55 2.45
1.12 0.83
2.00 1.80 1.30 1.10 0.80
4.90 4.25 3.35 2.90 2.20

1040 1075 1110F

0.85
0.85
2.20
0.65
0.65
1.80
0.50
0.50
1.45
0.40
0.40
1.20

d1
0.48
0.48
0.48
0.48
0.48
0.63
0.63
0.48
0.63
0.63
0.48
0.63
0.63
0.48
0.63
0.63

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F E
49 05 11 0.25 0.18 0.13
3
49 05 12 0.35 0.25 0.20
47/8
49 05 25
67/8
0.30 0.25 0.18
49 05 35
67/8
0.65 0.50 0.43 0.31 0.18
49 05 45
0.34 0.25 0.18 67/8
Type

1
1
1
1
1
11/8
11/8
1
11/8
11/8
1
11/8
11/8
1
11/8
11/8

A
4
6
63/4
63/4
63/4

B
2
3
4
4
4

C
9
9
9

H
2
4
57/8
57/8
57/8

lbs
1.8
3.7
7.9
7.9
7.9

4.16

SELECTION TABLE
OD 2.37- 60.3mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 2.37 (ND 50/2), types 42, 43, 45, 49

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F d4
E A
Type
0.41 27/8 33/4
42 06 17 0.56

permissible load (lbs x 1000)


210 480 660 840 930
42 06 19 1.65 1.20 0.85
Type

950

d2
0.48

985 1040 1075 1110F

B
1

lbs
0.6

load
group
C-D

E
B
21/8 11/2

lbs
1.7

load
group
C-2

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
43 06 19 1.65 1.20 0.85
43 06 39
1.95 1.75 1.15 1.00 0.70 0.40
43 06 49
0.90 0.65 0.49
Type

Type
45 06 11
45 06 12
45 06 11
45 06 12
45 06 11
45 06 12
45 06 11
45 06 12
45 06 39
45 06 31
45 06 32
45 06 39
45 06 31
45 06 32
45 06 39
45 06 31
45 06 32
45 06 39
45 06 31
45 06 32

permissible load (lbs x 1000)


210 480 660 840 930 950 985
2.00 1.50 1.05
5.35 4.00 2.90
1.45 1.05 0.75
3.80 2.90 2.10
1.10 0.85 0.60
2.90 2.20 1.65
0.90 0.65 0.45
2.45 1.90 1.35
1.12
4.45 3.80 2.65 2.45 1.75
4.90 4.25 4.00 4.00 3.80
1.12
3.35 2.90 2.20 1.90 1.35
4.90 4.25 4.00 4.00 2.90
1.12
2.65 2.45 1.80 1.55 1.10
4.90 4.25 3.80 3.35 2.45
1.12 0.97
2.20 2.10 1.50 1.30 0.95
4.90 4.25 3.35 2.90 2.05

1040 1075 1110F

0.95
0.95
2.15
0.75
0.75
1.65
0.60
0.60
1.35
0.50
0.50
1.10

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
49 06 11 0.30 0.23 0.16
49 06 12 0.40 0.30 0.22
49 06 25
0.30 0.25 0.18
49 06 35
0.65 0.50 0.43 0.31 0.18
49 06 45
0.40 0.27 0.18
Type

4.17

d1
0.48
0.48
0.48

E
61/8
77/8
77/8

B
11/2
2
2

lbs
2.6
3.5
4.6

load
group
C-4
C-4
C-4

B
23/4
31/8
23/4
31/8
23/4
31/8
23/4
31/8
4
4
43/4
4
4
43/4
4
4
43/4
4
4
43/4

L
113/4
113/4
153/4
153/4
193/4
193/4
231/2
231/2
153/4
153/4
153/4
193/4
193/4
193/4
231/2
231/2
231/2
271/2
271/2
271/2

lbs
10
16
12
20
15
25
17
29
25
25
40
30
30
48
36
36
55
41
41
65

load
group
C-4
1-4
C-4
1-4
C-4
1-4
C-4
1-4
C-D
1-4
1-4
C-D
1-4
1-4
C-D
1-4
1-4
C-D
1-4
1-4

d1
0.48
0.63
0.48
0.63
0.48
0.63
0.48
0.63
0.48
0.63
0.63
0.48
0.63
0.63
0.48
0.63
0.63
0.48
0.63
0.63

E
31/8
51/8
71/8
71/8
71/8

1
11/8
1
11/8
1
11/8
1
11/8
1
11/8
11/8
1
11/8
11/8
1
11/8
11/8
1
11/8
11/8

A
6
8
85/8
85/8
85/8

B
2
3
41/4
41/4
41/4

C
111/4
111/4
111/4

H
2
4
57/8
57/8
57/8

lbs
2.9
5.3
10.9
10.9
10.9

SELECTION TABLE
OD 2.87- 73mm
Pipe clamps, clamp bases, OD 2.87 (ND 65/21/2), types 42, 43, 45, 46, 48, 49
permissible load (kN)
Type
210 480 660 840 930 950 985
42 07 17 1.12

permissible load (lbs x 1000)


Type
210 480 660 840 930
42 07 19 1.65 1.20 0.85

950

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

1040 1075 1110F d4 E A


0.51 33/4 43/4

985

1040 1075 1110F

B lbs
11/4 1.1

lbs
1.8

load
group
C-2

lbs
2.6
4.0
5.0

load
group
C-4
C-4
C-4

E
B
23/8 11/2

d2
0.48

load
group
C-2

Heat resistant materials see page 4.3

Type
210
43 07 19 1.65
43 07 39
43 07 49

Type
45 07 19
45 07 11
45 07 12
45 07 19
45 07 11
45 07 12
45 07 19
45 07 11
45 07 12
45 07 19
45 07 11
45 07 12

permissible load (lbs x 1000)


480 660 840 930 950 985 1040 1075 1110F
1.20 0.85
1.95 1.75 1.15 1.00 0.70 0.40
0.90 0.65 0.49

E
d1
0.48 61/2
0.48 81/2
0.48 81/2

permissible load (lbs x 1000)


E
210 480 660 840 930 950 985 1040 1075 1110F d1
1.12
0.48 1
3.80 2.90 2.05
0.63 11/8
6.05 5.15 3.55
0.63 11/8
1.12
0.48 1
3.10 2.20 1.65
0.63 11/8
4.90 3.55 2.45
0.63 11/8
1.12
0.48 1
2.45 1.85 1.30
0.63 11/8
3.80 2.65 2.00
0.63 11/8
1.12 1.05
0.48 1
2.00 1.45 1.05
0.63 11/8
2.90 2.20 1.60
0.63 11/8

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040
4. 07 31
3.55 3.35 2.45 2.20 1.55 0.85
4. 07 32
4.70 4.45 3.35 2.90 2.20 1.30
4. 07 33
9.65 7.85 5.80 5.15 3.80 2.20
4. 07 41
1.50
4. 07 42
2.40
4. 07 43
4.00

1075 1110F d3
0.81
0.81
1.00
1.1 0.8 0.81
1.7 1.3 0.81
2.9 2.2 1.00

EK

ER
1/
23/4
2
1 3
11/4 37/8
1/
23/4
2
1 33/8
11/4 41/2

B
23/4
23/4
4
23/4
23/4
4
23/4
23/4
4
23/4
23/4
4

B
11/2
2
2

L
113/4
113/4
113/4
153/4
153/4
153/4
193/4
193/4
193/4
231/2
231/2
231/2

load
lbs group
14 C-D
14 1-4
19 1-4
17 C-D
17 1-4
24 1-4
21 C-D
21 1-4
30 1-4
24 C-D
24 1-4
35 1-4

L
lbs
min. max. min. max.
133/4 291/2 15 32
133/4 291/2 16 41
133/4 291/2 21 57
14 291/2 15 33
14 291/2 20 42
14 291/2 24 58

load
group
C-4
C-4
3-5
C-4
C-4
3-5

 Type 46

 Type 48

13/8

 Weights for Type 46 - for Type 48 approx. 12% less..

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F E
49 07 11 0.30 0.23 0.16
31/2
49 07 12 0.40 0.30 0.22
53/8
49 07 25
73/8
0.38 0.31 0.22
49 07 35
73/8
1.00 0.75 0.65 0.47 0.27
49 07 45
0.54 0.38 0.27 73/8

A
6
8
85/8
85/8
85/8

B
C
21/8
31/8
41/4 111/4
41/4 111/4
41/4 111/4

H lbs
3.3
2
5.7
4
57/8 11.3
57/8 11.3
57/8 11.3

4.18

SELECTION TABLE
OD 3.00- 76.1mm

Temperature up to
1200F see page 4.46

Pipe clamps, clamp bases, OD 3.00 (ND 65/21/2), types 42, 43, 45, 46, 48, 49

Twice the specified load is possible


by use of type 77 (see page 4.55)

permissible load (lbs x 1000)


A B
210 480 660 840 930 950 985 1040 1075 1110F d4
E
Type
0.51 33/4 43/4 11/4
42 08 17 1.12

lbs
1.2

load
group
C-2

permissible load (lbs x 1000)


Type
210 480 660 840 930
42 08 19 1.65 1.20 0.85

E
d2
B
0.48 21/2 11/2

lbs
2.0

load
group
C-2

B
11/2
2
2

lbs
2.6
4.0
5.0

load
group
C-4
C-4
C-4

L
113/4
113/4
113/4
153/4
153/4
153/4
193/4
193/4
193/4
231/2
231/2
231/2

lbs
15
15
21
18
18
26
22
22
31
25
25
36

load
group
C-D
1-4
1-4
C-D
1-4
1-4
C-D
1-4
1-4
C-D
1-4
1-4

950

985 1040 1075 1110F

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075
43 08 19 1.65 1.20 0.85
43 08 39
1.95 1.75 1.15 1.00 0.70 0.40
43 08 49
0.90 0.65

Type
45 08 19
45 08 11
45 08 12
45 08 19
45 08 11
45 08 12
45 08 19
45 08 11
45 08 12
45 08 19
45 08 11
45 08 12

 Type 46

 Type 48

13/8

1110F

0.49

d1
0.48
0.48
0.48

permissible load (lbs x 1000)


E
210 480 660 840 930 950 985 1040 1075 1110F d1
1.12
0.48 1
3.80 2.90 2.05
0.63 11/8
6.05 5.15 3.55
0.63 11/8
1.12
0.48 1
3.10 2.20 1.65
0.63 11/8
4.90 3.55 2.45
0.63 11/8
1.12
0.48 1
2.45 1.85 1.30
0.63 11/8
3.80 2.65 2.00
0.63 11/8
1.12 1.05
0.48 1
2.00 1.45 1.05
0.63 11/8
2.90 2.20 1.60
0.63 11/8

61/2
81/2
81/2

B
23/4
23/4
4
23/4
23/4
4
23/4
23/4
4
23/4
23/4
4

L
lbs
permissible load (lbs x 1000)
load
Type 210 480 660 840 930 950 985 1040 1075 1110F d3 EK ER min. max. min. max. group
4. 08 31
C-4
3.55 3.35 2.45 2.20 1.55 0.85
0.81 1/2 23/4 133/4 291/2 15 32
4. 08 32
C-4
4.70 4.45 3.35 2.90 2.20 1.30
0.81 1 3 133/4 291/2 15 41
4. 08 33
3-5
9.65 7.85 5.80 5.15 3.80 2.20
1.00 1 1 / 4 37/8 133/4 291/2 24 57
4. 08 41
C-4
0.8 0.81 1/2 23/4 14 291/2 15 33
1.5 1.1
4. 08 42
C-4
1.3 0.81 1 33/8 14 291/2 20 42
2.4 1.7
4. 08 43
3-5
2.2 1.00 11/4 41/2 14 291/2 29 60
4.0 2.9
 Weights for Type 46 - for Type 48 approx. 14% less.

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F E
31/2
49 08 11 0.30 0.23 0.16
51/2
49 08 12 0.40 0.30 0.22
73/8
49 08 25
0.38 0.31 0.22
73/8
49 08 35
1.00 0.75 0.65 0.47 0.27
49 08 45
0.54 0.38 0.27 73/8

4.19

A
6
8
85/8
85/8
85/8

B
21/8
31/8
41/4
41/4
41/4

C
111/4
111/4
111/4

H lbs
2
3.3
4
5.7
57/8 11.3
57/8 11.3
57/8 11.3

SELECTION TABLE
OD 3.50- 88.9mm
Pipe clamps, clamp bases, OD 3.50 (ND 80/3), types 42, 43, 45, 46, 48, 49

Twice the specified load is possible


by use of type 77 (see page 4.55)

permissible load (lbs x 1000)


A
210 480 660 840 930 950 985 1040 1075 1110F d4
E
B
Type
0.51 33/4 43/4 11/4
42 09 17 1.12

lbs
1.3

load
group
C-2

permissible load (lbs x 1000)


Type
210 480 660 840 930
42 09 19 1.45 1.00 0.75

B
11/2

lbs
2.2

load
group
C-2

lbs
3.1
3.1
4.2
4.2
5.4

load
group
C-D
1-4
C-D
1-4
C-4

950

Temperature up to
1200F see page 4.46

E
d2
0.48 23/4

985 1040 1075 1110F

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F
43 09 18
0.46
43 09 19 1.65 1.20 0.85
43 09 38
0.46 0.40
43 09 39
1.95 1.75 1.15 1.00 0.70 0.40
43 09 49
0.90 0.65 0.49

Type
45 09 19
45 09 11
45 09 12
45 09 19
45 09 11
45 09 12
45 09 19
45 09 11
45 09 12
45 09 19
45 09 11
45 09 12
Type
4. 0931
4. 09 32
4. 09 33
4. 09 41
4. 09 42
4. 09 43

210
3.80
6.05
2.65
4.25
2.00
2.90
1.55
2.20

d1
0.48
0.63
0.48
0.63
0.48

E
63/4
63/4
91/4
91/4
91/4

11/2
11/2
2
2
2

permissible load (lbs x 1000)


E
480 660 840 930 950 985 1040 1075 1110F d1
1.12
0.48 1
2.90 2.10
0.63 11/8
5.15 3.55
0.63 11/8
1.12
0.48 1
2.00 1.40
0.63 11/8
3.10 2.20
0.63 11/8
1.12
0.48 1
1.45 1.05
0.63 11/8
2.20 1.60
0.63 11/8
1.12 0.80
0.48 1
1.15 0.80
0.63 11/8
1.75 1.25
0.63 11/8

B
23/4
23/4
4
23/4
23/4
4
23/4
23/4
4
23/4
23/4
4

L
113/4
113/4
113/4
173/4
173/4
173/4
231/2
231/2
231/2
291/2
291/2
291/2

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075
3.55 3.35 2.45 2.20 1.55 0.85
4.70 4.45 3.35 2.90 2.20 1.30
9.65 7.85 5.80 5.15 3.80 2.20
1.5 1.1
2.4 1.7
4.2 2.9

1110F d3
0.81
0.81
1.00
0.8 0.81
1.3 0.81
2.2 1.00

EK
1/
2

1
13/8
1/
2

1
13/8

ER
3
33/8
37/8
3
37/8
41/8

load
lbs group
15 C-D
15 1-4
21 1-4
20 C-D
20 1-4
28 1-4
26 C-D
26 1-4
36 1-4
31 C-D
31 1-4
44 1-4

L
lbs
load
min. max. min. max. group
C-4
133/4 331/2 16 46
C-4
133/4 331/2 16 58
3-5
133/4 331/2 24 66
C-4
14 331/2 18 40
C-4
14 331/2 20 53
3-5
14 331/2 26 77

 Type 46

 Type 48

13/8

 Weights for Type 46 - for Type 48 approx. 15% less.

Type
49 09 11
49 09 12
49 09 25
49 09 35
49 09 45

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
0.40 0.33 0.23
0.55 0.44 0.30
0.50 0.43 0.31
1.20 0.90 0.80 0.56 0.35
0.65 0.49 0.35

E
A
33/4 6
53/4 8
95/8 105/8
95/8 105/8
95/8 105/8

B
23/8
33/8
53/4
53/4
53/4

C
131/4
131/4
131/4

H
2
4
77/8
77/8
77/8

lbs
5.1
8.4
17.4
17.4
17.4

4.20

SELECTION TABLE
OD 4.25- 108mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 4.25 (ND 100/4), types 42, 43, 45, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950
42 10 19 2.20 1.70 1.30

E
d2
0.63 31/2

985 1040 1075 1110F

B
2

lbs
4.4

load
group
1-4

Heat resistant materials see page 4.3

Type 210
43 10 19 2.20
43 10 29
43 10 38
43 10 39
43 10 49

Type
45 10 19
45 10 11
45 10 19
45 10 11
45 10 19
45 10 11
45 10 19
45 10 11
 Type 46

permissible load (lbs x 1000)


480 660 840 930 950
1.70 1.30
0.65 0.40

0.56 0.50
2.45 2.20 1.55 1.35 0.95 0.50
1.35 0.99 0.74

permissible load (lbs x 1000)


210 480 660 840 930 950
1.12
3.80 2.90 2.15
1.12
2.65 2.05 1.50
1.12
2.10 1.55 1.10
1.12 0.85
1.65 1.25 0.85

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985
4. 10 12 4.0 3.1 2.2
4. 10 31
4.7 4.4 3.8 3.3 2.4
4. 10 32
8.0 6.7 5.1 4.4 3.3
4. 10 33
13.9 11.2 8.9 7.8 5.6
4. 10 41
4. 10 42
4. 10 43

 Type 48

d1
0.63
0.48
0.48
0.63
0.63

985 1040 1075 1110F

985 1040 1075 1110F

1040 1075 1110F d3


1.00
1.3
0.81
1.7
1.00
3.3
1.34
2.4 1.7 1.3 0.81
3.1 2.2 1.7 1.00
5.3 4.0 3.3 1.34

d1
0.48
0.63
0.48
0.63
0.48
0.63
0.48
0.63

EK

ER
1/
23/4
4
1/
33/8
2
1 33/8
13/8 43/4
1/
37/8
2
1 43/8
13/8 51/8

E
1
11/8
1
11/8
1
11/8
1
11/8

load
group
1-4
C-4
C-D
1-4
1-4

8
91/2
101/2
101/2
101/2

B
2
11/2
2
2
23/4

lbs
5.5
2.9
6.6
6.6
9.0

B
31/8
31/8
31/8
31/8
31/8
31/8
31/8
31/8

load
L
lbs group
133/4 18 C-D
133/4 18 1-4
193/4 25 C-D
193/4 25 1-4
251/2 31 C-D
251/2 31 1-4
311/2 37 C-D
311/2 37 1-4

L
lbs
load
min. max. min. max. group
131/2 311/2 17 41
3-5
133/4 371/2 19 57
C-4
133/4 371/2 32 72
3-5
133/4 371/2 35 101
3-6
14 371/2 22 63
C-4
14 371/2 31 80
3-5
14 371/2 40 116
3-6

 Weights for Type 46 - for Type 48 approx. 16% less.

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F
49 10 11 0.50 0.40 0.30
49 10 12 0.70 0.55 0.40
49 10 25
0.65 0.60 0.45
49 10 35
1.20 1.05 0.90 0.65 0.40
49 10 45
0.74 0.54 0.40

4.21

E
A
6 6
8 8
10 103/8
10 103/8
10 103/8

B
33/4
5
6
6
6

C
131/2
131/2
131/2

H
4
57/8
77/8
77/8
77/8

lbs
9
14
23
23
23

SELECTION TABLE
OD 4.50- 114.3mm
Pipe clamps, clamp bases, OD 4.50 (ND 100/4), types 42, 43, 45, 46, 48, 49
permissible load (lbs x 1000)
210 480 660 840 930
Type
42 11 19 2.20 1.70 1.30

950

985

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)
E
d2
0.63 35/8

1040 1075 1110F

B
2

lbs
4.6

load
group
1-4

B
2
11/2
2
2
23/4

lbs
5.7
3.3
6.6
6.6
9.1

load
group
1-4
C-4
C-D
1-4
1-4

L
133/4
133/4
193/4
193/4
251/2
251/2
311/2
311/2

lbs
19
19
25
25
32
32
38
38

load
group
C-D
1-4
C-D
1-4
C-D
1-4
C-D
1-4

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985
43 11 19 2.20 1.70 1.30
0.65 0.40
43 11 29
0.56
43 11 38
2.45 2.20 1.55 1.35 0.95
43 11 39
43 11 49

Type
45 11 19
45 11 11
45 11 19
45 11 11
45 11 19
45 11 11
45 11 19
45 11 11

Type
4. 1112
4. 11 31
4. 11 32
4. 11 33
4. 11 41
4. 11 42
4. 11 43

210
3.80
2.65
2.10
1.65

1040 1075 1110F

0.50
0.50
1.35 0.99

0.74

d1
0.63
0.48
0.48
0.63
0.63

permissible load (lbs x 1000)


E
480 660 840 930 950 985 1040 1075 1110F d1
1.12
0.48 1
2.90 2.15
0.63 11/8
1.12
0.48 1
2.05 1.50
0.63 11/8
1.12
0.48 1
1.55 1.10
0.63 11/8
1.12 0.85
0.48 1
1.25 0.85
0.63 11/8

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F d3
4.0 3.1 2.2
1.00
4.7 4.4 3.8 3.3 2.4 1.3
0.81
8.0 6.7 5.1 4.4 3.3 1.7
1.00
13.9 11.2 8.9 7.8 5.6 3.3
1.34
2.4 1.7 1.3 0.81
3.1 2.2 1.7 1.00
5.3 4.0 3.3 1.34

EK
1/
4
1/
2

1
13/8
1/
2

1
13/8

ER
23/4
33/8
33/8
43/4
37/8
43/8
51/8

E
8
91/2
101/2
101/2
101/2

B
31/8
31/8
31/8
31/8
31/8
31/8
31/8
31/8

L
lbs
load
min. max. min. max. group
131/2 311/2 17 42
3-5
133/4 371/2 19 58
C-4
133/4 371/2 33 74
3-5
133/4 371/2 37 102 3-6
14 371/2 22 63
C-4
14 371/2 33 80
3-5
14 371/2 42 117 3-6

 Type 46

 Type 48

 Weights for Type 46 - for Type 48 approx. 17% less.

Type

210
49 11 11 0.50
49 11 12 0.70
49 11 25
49 11 35
49 11 45

permissible load (lbs x 1000)


480 660 840 930 950 985 1040 1075 1110F E
A
61/4 6
0.40 0.30
81/8 8
0.55 0.40
101/8 103/8
0.65 0.60 0.45
101/8 103/8
1.20 1.05 0.90 0.65 0.40
0.74 0.54 0.40 101/8 103/8

B
33/4
5
6
6
6

C
131/2
131/2
131/2

H
4
57/8
77/8
77/8
77/8

lbs
9
14
23
23
23

4.22

SELECTION TABLE
OD 5.25- 133mm

Temperature up to
1200F see page 4.46

Pipe clamps, clamp bases, OD 5.25 (ND 125/5), types 42, 43, 45, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930
42 13 19 2.20 1.70 1.25

950

985 1040 1075 1110F

Twice the specified load is possible


by use of type 77 (see page 4.55)
d2
0.63

E
4

load
group
1-4

B
2

lbs
4.9

B
2
2
2
23/8
23/8
23/4

load
lbs group
6.2 1-4
5.1 C-D
5.1 1-4
8.6 C-D
8.6 1-4
12.0 1-4

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F
43 13 19 2.20 1.70 1.30
0.56
43 13 28
1.00 0.60
43 13 29
0.56 0.55
43 13 38
2.65 2.45 1.65 1.45 1.05 0.55
43 13 39
1.35 0.99 0.74
43 13 49

Type
45 13 19
45 13 11
45 13 19
45 13 11
45 13 19
45 13 11
45 13 19
45 13 11

E
d1
0.63 83/4
0.48 101/2
0.63 101/2
0.48 111/2
0.63 111/2
0.63 111/2

permissible load (lbs x 1000)


E
480 660 840 930 950 985 1040 1075 1110F d1
1.12
0.48 1
4.00 3.10 2.20
0.63 11/8
1.12
0.48 1
2.90 2.15 1.55
0.63 11/8
1.12
0.48 1
2.20 1.65 1.15
0.63 11/8
1.12 0.90
0.48 1
1.75 1.30 0.90
0.63 11/8
210

B
31/2
31/2
31/2
31/2
31/2
31/2
31/2
31/2

L
153/4
153/4
211/2
211/2
271/2
271/2
331/2
331/2

lbs
24
24
31
31
38
38
45
45

load
group
C-D
1-4
C-D
1-4
C-D
1-4
C-D
1-4

 Type 46

Type
4. 13 12
4. 13 31
4. 13 32
4. 13 33
4. 13 41
4. 13 42
4. 13 43

 Type 48

permissible load (lbs x 1000)


210 480 660 840 930 950 985
4.9 4.0 2.9
5.1 4.7 4.4 3.8 2.6
8.3 7.8 5.8 5.1 3.8
14.6 12.3 10.1 8.9 6.5

1040 1075 1110F d3


1.00
0.81
1.5
1.00
2.2
1.34
3.8
2.6 2.0 1.5 0.81
4.0 2.9 2.2 1.00
6.9 5.1 3.8 1.34

EK
3/
8
1/
2
1/
4
1/
2
1/
2
1/
4
1/
2

1
1
1
1

ER
23/4
33/4
37/8
51/8
41/8
41/2
53/4

L
lbs
load
min. max. min. max. group
151/2 331/2 28 51 3-5
153/4 391/2 25 71 C-4
153/4 391/2 34 86 3-5
153/4 391/2 51 128 4-6
16 391/2 29 76 C-4
16 391/2 40 99 3-5
16 391/2 57 148 4-6

 Weights for Type 46 - for Type 48 approx. 18% less.

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
49 13 11 0.55 0.45 0.33
49 13 12 0.85 0.65 0.45
1.00 0.85 0.60
49 13 25
1.90 1.45 1.30 0.95 0.55
49 13 35
0.99 0.74 0.55
49 13 45
Type

4.23

E
A
B
C
61/2 6 41/8
81/2 8 51/8
101/2 101/2 61/4 133/4
101/2 101/2 61/4 133/4
101/2 101/2 61/4 133/4

H
4
57/8
77/8
77/8
77/8

lbs
12
18
24
24
24

SELECTION TABLE
OD 5.50- 139.7mm
Pipe clamps, clamp bases, OD 5.50 (ND 125/5), types 42, 43, 45, 46, 48, 49
permissible load (lbs x 1000)
210 480 660 840 930
Type
42 14 19 2.20 1.65 1.15

950

Temperature up to
1200F see page 4.46

985 1040 1075 1110F

Twice the specified load is possible


by use of type 77 (see page 4.55)
E
B
41/8 2

d2
0.63

lbs
5.3

load
group
1-4

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F
43 14 19 2.20 1.70 1.30
43 14 28
0.56
43 14 29
1.00 0.60
43 14 38
0.56
43 14 39
2.65 2.45 1.65 1.45 1.05 0.55
43 14 49
1.35 0.99 0.74

Type
45 14 19
45 14 11
45 14 19
45 14 11
45 14 19
45 14 11
45 14 19
45 14 11

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F d1
1.12
0.48
4.00 3.10 2.20
0.63
1.12
0.48
2.90 2.15 1.55
0.63
1.12
0.48
2.20 1.65 1.15
0.63
1.12 0.90
0.48
1.75 1.30 0.90
0.63

permissible load (lbs x 1000)


210 480 660 840 930 950 985
4. 14 12 4.9 3.8 2.6
4. 14 31
5.1 4.7 4.4 3.8 2.6
4. 14 32
8.3 7.8 5.8 5.1 3.8
4. 14 33
14.6 12.3 10.1 8.9 6.5
4. 14 41
4. 14 42
4. 14 43
Type

1040 1075 1110F d3


1.00
1.5
0.81
2.2
1.00
3.8
1.34
2.6 2.0 1.5 0.81
4.0 2.9 2.2 1.00
6.9 5.1 3.8 1.34

EK
3/
8
1/
2
1/
4
1/
2
1/
2
1/
4
1/
2

1
1
1
1

ER
23/4
33/4
37/8
51/8
41/8
41/2
53/4

d1
0.63
0.48
0.63
0.48
0.63
0.63

E
1
11/8
1
11/8
1
11/8
1
11/8

E
83/4
103/4
103/4
111/2
111/2
111/2

B
31/2
31/2
31/2
31/2
31/2
31/2
31/2
31/2

load
B lbs group
2
6.4 1-4
2
5.5 C-D
2
5.5 1-4
23/8 9.0 C-D
23/8 9.0 1-4
23/4 12.0 1-4

L
153/4
153/4
211/2
211/2
271/2
271/2
331/2
331/2

L
min. max.
151/2 331/2
153/4 391/2
153/4 391/2
153/4 391/2
16 391/2
16 391/2
16 391/2

lbs
24
24
32
32
39
39
45
45

load
group
C-D
1-4
C-D
1-4
C-D
1-4
C-D
1-4

lbs
load
min. max. group
56 3-5
21
71 C-4
26
86 3-5
37
47 128 4-6
77 C-4
31
44 103 3-5
57 146 4-6

 Type 46

 Type 48

 Weights for Type 46 - for Type 48 approx. 19% less.

permissible load (lbs x 1000)


210 480 660 840 930 950 985
49 14 11 0.55 0.45 0.33
49 14 12 0.85 0.65 0.45
49 14 25
1.00 0.85 0.60
49 14 35
1.90 1.45 1.30 0.95
49 14 45
Type

1040 1075 1110F

0.55
0.99 0.74 0.55

A
E
63/4 6
83/4 8
105/8 101/2
105/8 101/2
105/8 101/2

B
C
41/8
51/8
61/4 133/4
61/4 133/4
61/4 133/4

H
4
57/8
77/8
77/8
77/8

lbs
12
19
25
25
25

4.24

SELECTION TABLE
OD 6.25- 159mm

Temperature up to
1200F see page 4.46

Pipe clamps, clamp bases, OD 6.25 (ND 150/6), types 42, 43, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950
42 16 19 2.00 1.45 1.05

985 1040 1075 1110F

Twice the specified load is possible


by use of type 77 (see page 4.55)
d2
0.63

E
B
41/2 2

lbs
5.5

load
group
1-4

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F d1
0.63
43 16 19 2.20 1.65 1.20
1.65 1.20 0.75
0.63
43 16 29
3.35 3.10 2.65 2.20 1.65 0.90
0.63
43 16 39
1.84 1.37 1.01 0.63
43 16 49

Type
4. 16 11
4. 16 12
4. 16 31
4. 16 32
4. 16 33
4. 16 41
4. 16 42
4. 16 43

 Type 46

permissible load (lbs x 1000)


210 480 660 840 930 950
4.0 3.1 2.2
6.2 4.9 3.5
5.1 4.4 4.2 3.8
10.3 8.9 6.9 6.0
16.8 13.0 11.9 10.3

985 1040 1075 1110F d3


0.81
1.00
0.81
2.9 1.5
1.00
4.4 2.4
1.34
7.6 4.4
2.6 2.0 1.5 0.81
4.2 3.1 2.4 1.00
7.8 5.8 4.4 1.34

EK
1/
2
1/
2

1
11/2
2
1
11/2
2

ER
31/2
33/8
37/8
43/4
57/8
43/8
51/8
61/2

E
93/4
113/4
121/2
121/2

B
2
2
31/8
31/8

load
lbs group
6.8 1-4
7.5 1-4
15.2 1-4
18.0 1-4

L
lbs
min. max. min. max.
171/2 351/2 24 55
171/2 351/2 26 71
173/4 411/2 30 79
173/4 411/2 41 107
173/4 411/2 61 154
18 411/2 37 84
18 411/2 49 113
18 411/2 73 177

load
group
C-4
3-5
C-4
3-5
4-6
C-4
3-5
4-6

 Weights for Type 46 - for Type 48 approx. 16% less.

 Type 48

21/2

Type
49 16 11
49 16 14
49 16 25
49 16 35
49 16 45

4.25

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
0.55 0.45 0.33
1.00 0.80 0.75
1.25 1.15 0.85
2.70 2.05 1.80 1.35 0.75
1.44 1.08 0.75

E
7
9
11
11
11

A
8
95/8
121/4
123/8
123/8

C
B
41/2
51/2 131/2
63/4 151/2
63/4 153/4
63/4 153/4

H lbs
15
4
57/8 24
77/8 28
77/8 28
77/8 28

SELECTION TABLE
OD 6.625- 168.3mm
Pipe clamps, clamp bases, OD 6.625 (ND 150/6), types 42, 43, 46, 48, 49
permissible load (lbs x 1000)
210 480 660 840 930
Type
42 17 19 1.90 1.40 1.00

950

Temperature up to
1200F see page 4.46

985 1040 1075 1110F

Twice the specified load is possible


by use of type 77 (see page 4.55)
E
d2
0.63 43/4

lbs
5.7

load
group
1-4

B lbs
2
7.1
2
7.9
31/8 16.1
31/8 19.0

load
group
1-4
1-4
1-4
1-4

B
2

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F d1
43 17 19 2.10 1.60 1.10
0.63
43 17 29
1.75 1.60 1.00
0.63
43 17 39
3.35 3.10 2.65 2.20 1.65 0.90
0.63
43 17 49
1.84 1.37 1.01 0.63

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
4. 1711 4.0 3.1 2.2
4. 17 12 6.2 4.9 3.5
5.1 4.4 4.2 3.8 2.9 1.5
4. 17 31
10.3 8.9 6.9 6.0 4.4 2.4
4. 17 32
16.8 13.0 11.9 10.3 7.6 4.4
4. 17 33
2.6 2.0 1.5
4. 17 41
4.2 3.1 2.4
4. 17 42
7.8 5.8 4.4
4. 17 43
Type

d3
0.81
1.00
0.81
1.00
1.34
0.81
1.00
1.34

EK
1/
2
1/
2

1
11/2
2
1
11/2
2

ER
31/2
33/8
37/8
43/4
57/8
43/8
51/8
61/2

E
93/4
113/4
121/2
121/2

L
min. max.
171/2 351/2
171/2 351/2
173/4 411/2
173/4 411/2
173/4 411/2
18 411/2
18 411/2
18 411/2

lbs
load
min. max. group
25 55 C-4
42 72 3-5
31 80 C-4
47 107 3-5
64 163 4-6
37 85 C-4
51 117 3-5
75 179 4-6

 Weights for Type 46 - for Type 48 approx. 19% less.

 Type 46

 Type 48

21/2

Type
49 17 11
49 17 14
49 17 25
49 17 35
49 17 45

permissible load (lbs x 1000)


E
210 480 660 840 930 950 985 1040 1075 1110F
A
71/4 8
0.55 0.45 0.33
91/4 95/8
1.05 0.90 0.85
111/4 121/4
1.30 1.20 0.85
111/4 123/8
2.70 2.05 1.80 1.35 0.75
1.46 1.10 0.75 111/4 123/8

B
43/4
6
63/4
63/4
63/4

C
131/2
151/2
153/4
153/4

H
4
57/8
77/8
77/8
77/8

lbs
15
25
29
29
29

4.26

SELECTION TABLE
OD 7.625- 193.7mm

Temperature up to
1200F see page 4.46

Pipe clamps, clamp bases, OD 7.625 (ND 175/7), types 42, 43, 46, 48, 49
permissible load (lbs x 1000)
210 480 660 840 930 950
Type
42 19 19 1.55 1.20 0.85

985

1040 1075 1110F

Twice the specified load is possible


by use of type 77 (see page 4.55)
d2
0.63

E
B
51/2 2

lbs
6.4

load
group
1-4

lbs
10.3
9.3
23.8
23.8
34.0

load
group
1-5
1-5
1-3
3-6
3-6

Heat resistant materials see page 4.3

Type 210
43 19 19 2.65
43 19 29
43 19 38
43 19 39
43 19 49

permissible load (lbs x 1000)


E
480 660 840 930 950 985 1040 1075 1110F d1
2.00 1.45
0.63 101/2
1.30 0.80
0.63 133/4
2.20 2.10 2.00 1.90 1.75 1.30
0.63 14
4.90 4.45 4.00 3.55 2.90 1.60
0.79 14
2.92 2.25 1.69 0.79 14

permissible load (lbs x 1000)


210 480 660 840 930 950 985
4. 1911 5.3 4.2 2.9
4. 19 12 8.3 6.5 4.7
4. 19 21
5.6 4.9 3.5
4. 19 22
8.9 7.6 5.6
4. 19 31
3.3 2.2
4. 19 32
6.2 5.6 4.0
4. 19 33
8.7 7.6 5.6
4. 19 34
15.9 13.0 9.6
4. 19 41
4. 19 42
4. 19 43
4. 19 44
Type

 Type 46

 Type 48

1040 1075 1110F d3


0.81
1.00
0.81
1.00
0.81
1.3
1.00
2.2
1.00
3.1
1.60
5.6
2.2 1.7 1.3 0.81
3.8 2.9 2.2 1.00
5.3 4.0 3.1 1.00
10.1 7.4 5.6 1.60

EK
1/
2
3/
4
1/
2
1/
4

1
1
11/4
11/2
2
1
11/4
11/2
2

ER
31/8
31/2
37/8
43/8
43/8
43/8
51/8
61/4
41/2
51/8
51/2
61/4

L
min.
191/2
191/2
193/4
193/4
213/4
213/4
213/4
213/4
211/2
211/2
211/2
211/2

B
2
2
23/4
23/4
37/8

lbs
load
max. min. max. group
371/2 31 63 C-4
371/2 38 92 3-5
391/2 31 70 C-4
391/2 44 94 3-5
451/2 36 87 C-4
451/2 56 118 3-5
451/2 69 139 3-5
451/2 100 208 4-7
451/2 44 92 C-4
451/2 62 128 3-5
451/2 82 172 3-5
451/2 119 241 4-7

 Weights for Type 46 - for Type 48 approx. 19% less.

21/2

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F E
A
B
73/4 95/8 51/8
49 19 13 0.95 0.85 0.80
93/4 93/4 6
49 19 14 1.60 1.50 1.30
113/4 121/2 71/8
1.80 1.55 1.15
49 19 25
133/4 121/2 8
3.60 2.70 2.50 1.75 1.00
49 19 35
2.05 1.53 1.00 133/4 121/2 8
49 19 45
Type

4.27

C
131/2
137/8
153/4
161/4
161/4

H
4
57/8
77/8
97/8
97/8

lbs
22
31
31
47
48

SELECTION TABLE
OD 8.625- 219.1mm

Twice the specified load is possible


by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 8.625 (ND 200/8), types 42, 43, 44, 46, 48, 49
permissible load (lbs x 1000)
210 480 660 840 930 950
42 22 19 1.55 1.15 0.80
Type

Temperature up to
1200F see page 4.46

985

1040 1075 1110F

E
d2
0.63 53/4

985

1040 1075 1110F

E
d1
0.63 111/2
0.63 141/2

lbs
6.8

load
group
1-4

B
2
2

lbs
11
12

load
group
1-5
1-5

lbs
24
19
30
48
23
33
52

load
group
3-6
C-4
4-6
5-8
C-4
4-6
5-8

B
2

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


210 480 660 840 930 950
43 22 19 2.65 2.00 1.45
43 22 29
2.00 1.75 1.10
Type

permissible load (lbs x 1000)


E
210 480 660 840 930 950 985 1040 1075 1110F d3
44 22 12 6.5 5.1
4.0
1.34 103/4
44 22 31
2.0 1.7
2.2 2.0
1.1
0.81 143/4
44 22 32
5.1 4.0
2.4
6.5 5.8 5.3
1.34 143/4
44 22 33
7.8 6.5
3.8
11.9 10.1 8.5
1.80 143/4
44 22 41
1.3 1.1 0.81 143/4
2.0
44 22 42
3.1 2.4 1.34 143/4
4.2
44 22 43
11.5
5.3 3.8 1.80 143/4
7.4
Type

33/8
35/8
33/4
43/4
37/8
37/8
51/8

 Type 46

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F d3
4.2211 5.3 4.0 2.9
0.81
4. 22 12 9.4 7.1 5.1
1.00
4. 22 21
1.00
7.4 6.9 4.9
4. 22 22
1.34
10.5 9.4 6.9
4. 22 31
0.81
3.3 2.2 1.3
4. 22 32
1.00
8.0 6.9 5.1 2.9
4. 22 33
1.60
11.4 9.4 6.9 4.0
4. 22 34
1.80
19.7 16.1 11.9 6.9
4. 22 41
2.2 1.7 1.3 0.81
4. 22 42
5.1 3.8 2.9 1.00
4. 22 43
7.1 5.3 4.0 1.60
4. 22 44
12.3 9.2 6.9 1.80
Type

EK
1/
2

1
13/8
11/2
1
11/2
2
21/2
1
11/2
2
21/2

ER
41/8
43/8
43/4
57/8
51/8
57/8
63/4
77/8
51/8
61/8
71/4
77/8

L
min.
191/2
191/2
193/4
193/4
213/4
213/4
213/4
213/4
211/2
211/2
211/2
211/2

max.
431/2
431/2
471/2
471/2
471/2
471/2
471/2
471/2
53
53
53
53

lbs
load
min. max. group
34 87 C-4
52 119 3-5
46 122 3-5
55 160 4-6
41 109 C-4
72 173 3-5
93 218 4-7
134 313 5-8
49 120 C-4
86 207 3-5
106 252 4-7
154 369 5-8

 Type 48

6431/8

 Weights for Type 46 - for Type 48 approx. 18% less.

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F E
81/4
49 22 13 1.50 1.30 1.25
101/4
49 22 14 2.20 1.90 1.80
141/4
2.10 2.00 1.45
49 22 25
141/4
4.45 3.40 2.90 2.25 1.30
49 22 35
2.25 1.82 1.30 141/4
49 22 45
Type

A
95/8
101/8
123/8
123/8
123/8

B
51/8
61/8
81/4
81/4
81/4

C
133/4
141/4
153/4
161/4
161/4

H
4
57/8
97/8
97/8
97/8

lbs
26
33
37
49
50

4.28

SELECTION TABLE
OD 9.625- 244.5mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 9.625 (ND 225/9), types 42, 43, 44, 46, 48, 49
permissible load (lbs x 1000)
210 480 660 840 930
42 24 19 1.40 1.05 0.75
Type

950

985 1040 1075 1110F

d2
E
0.63 61/4

load
lbs group
7.3 1-4

B
2

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


210 480 660 840 930 950
43 24 19 2.65 2.45 1.85
2.00 1.75 1.10
43 24 29
Type

permissible load (lbs x


210 480 660 840
44 24 12 4.4 3.5 2.6
44 24 13 8.5 7.8 6.5
44 24 31
2.1
44 24 32
6.7 5.8
44 24 33
11.6 10.1
44 24 41
44 24 42
44 24 43
Type

1000)
930 950

2.0
5.3
8.5

1.9
5.1
7.8

985 1040 1075 1110F

d1
0.63
0.63

985 1040 1075 1110F

d3
1.34
1.80
0.81
1.34
1.80
0.81
1.34
1.80

1.7
4.0
6.5

11.5

1.1
2.4
3.8
2.0
4.0
7.4

1.3
3.1
5.3

1.1
2.4
3.8

E
121/4
151/4

E
113/4
13
151/2
151/2
151/2
151/4
151/4
151/4

B
2
2

lbs
13
13

load
group
1-5
1-5

lbs
19
27
20
33
51
24
36
55

load
group
3-6
5-8
C-4
4-6
5-8
C-4
4-6
5-8

27/8
31/8
35/8
33/4
43/4
37/8
37/8
51/8

 Type 46

permissible load (lbs x 1000)


210 480 660 840 930 950 9851040 1075 1110F d3 EK
4.2411 6.7 5.1 3.8
1.00 1
4. 24 12 11.2 8.9 6.2
1.34 13/8
4. 24 21
8.5 7.6 5.3
1.00 11/2
4. 24 22
11.9 10.1 7.6
1.34 13/4
3.8 2.6 1.5
1.00 11/4
4. 24 31
8.9 7.6 5.3 3.1
1.00 13/4
4. 24 32
4.4
12.5
10.3
7.6
1.60 2
4. 24 33
21.5 18.0 13.0 7.6
1.80 21/2
4. 24 34
2.6 2.0 1.5 1.00 11/4
4. 24 41
5.6 4.0 3.1 1.00 13/4
4. 24 42
8.0 6.0 4.4 1.60 2
4. 24 43
13.7 10.3 7.6 1.80 21/2
4. 24 44
Type

 Type 48

64 31/8

L
ER
37/8
43/4
51/8
57/8
43/8
57/8
61/4
71/8
43/4
57/8
61/4
71/2

min.
191/2
191/2
213/4
213/4
213/4
213/4
213/4
213/4
211/2
211/2
211/2
211/2

max.
431/2
431/2
471/2
471/2
531/2
531/2
531/2
531/2
53
53
53
53

lbs
min. max.
42 104
63 137
55 134
74 171
48 124
81 186
103 237
150 340
57 134
95 224
119 275
172 397

load
group
3-5
4-6
3-5
4-6
3-5
3-5
4-7
5-8
3-5
3-5
4-7
5-8

 Weights for type 46 - for type 48 approx. 22% less.

Type
49 24 13
49 24 14
49 24 25
49 24 35
49 24 45

4.29

permissible load (lbs


210 480 660 840
1.55 1.30 1.25
2.50 2.15 2.05
2.90 2.65
6.05

x 1000)
930 950 985 1040 1075 1110F

1.90
4.50 4.00 2.90 1.70
3.37 2.47

E
83/4
103/4
145/8
145/8
1.70 145/8

A
95/8
101/8
123/8
125/8
125/8

B
51/8
63/4
83/4
83/4
83/4

C
133/4
141/4
161/4
161/2
161/2

H
4
57/8
97/8
97/8
97/8

lbs
27
36
51
53
54

SELECTION TABLE
OD 10.50- 267mm
Pipe clamps, clamp bases, OD 10.50 (ND 250/10), types 42, 43, 44, 46, 48, 49
permissible load (lbs x 1000)
210 480 660 840 930 950
Type
42 26 19 1.45 1.10 0.75

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

985 1040 1075 1110F

d2
0.79

985 1040 1075 1110F

d1
E
0.63 131/2
0.95 131/2
0.95 161/4

B lbs
23/8 10

E
7

load
group
3-4

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type
210 480 660 840 930 950
43 26 18 2.05 2.00 1.90
43 26 19 6.50 4.00 3.10
43 26 29
2.45 1.65

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F d3
Type
1.34
3.5
44 26 12 5.8 4.7
1.80
9.4
44 26 13 13.2 12.1
0.81
2.0
1.9 1.7 1.7 1.1
44 26 31
1.34
5.1
4.9 4.7 3.8 2.4
44 26 32
1.80
10.5 8.9
8.5 7.8 6.5 4.0
44 26 33
1.1 0.81
1.7 1.3
44 26 41
2.4 1.34
4.4 3.3
44 26 42
4.0 1.80
11.0 7.4 5.3
44 26 43

E
131/2
141/4
163/4
163/4
163/4
163/4
163/4
163/4

B
23/4
23/4
23/4

lbs
26
26
23

load
group
1-3
3-6
3-6

lbs
22
45
22
34
54
29
42
59

load
group
4-6
5-8
C-4
4-6
5-8
C-4
4-6
5-8

27/8
43/8
35/8
33/4
43/4
41/8
41/2
51/8

 Type 46

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075
Type
4.2611 7.8 6.2 4.4
4. 26 12 11.9 9.2 6.7
8.9 8.0 5.8
4. 26 21
12.1 11.2 8.0
4. 26 22
4.4 3.3 1.7
4. 26 31
9.2 7.8 5.6 3.3
4. 26 32
13.2 11.0 8.0 4.7
4. 26 33
22.4 18.8 13.7 8.0
4. 26 34
3.1 2.2
4. 26 41
6.0 4.4
4. 26 42
8.5 6.2
4. 26 43
14.6 11.0
4. 26 44
 Weights for type 46 - for type 48 approx. 20% less.

permissible load (lbs


Type 210 480 660 840
49 26 13 1.90 1.60 1.55
49 26 14 3.55 3.10 2.90
3.40 3.15
49 26 25
7.20
49 26 35
49 26 45

x 1000)
930 950 985

2.25
5.40 4.75 3.40

1110F d3
1.00
1.34
1.00
1.34
1.00
1.00
1.60
1.80
1.7 1.00
3.3 1.00
4.7 1.60
8.0 1.80

EK
13/8
13/4
13/4
2
11/4
2
2
23/4
11/4
2
2
23/4

1040 1075 1110F

2.00
3.82 2.92

2.00

L
ER min. max.
41/8 211/2 451/2
51/8 211/2 451/2
51/2 233/4 511/2
57/8 233/4 511/2
43/4 233/4 551/2
57/8 233/4 551/2
61/4 233/4 551/2
71/4 233/4 551/2
51/2 231/2 55
67/8 231/2 55
61/2 231/2 55
81/8 231/2 55

E
91/4
111/8
151/8
151/8
151/8

A
93/4
105/8
131/2
133/4
133/4

B
61/4
63/4
9
9
9

lbs
load
min. max. group
52 122 3-5
69 155 4-6
65 160 3-5
79 212 4-6
69 144 3-5
93 207 3-5
119 262 4-7
174 378 5-8
79 165 3-5
112 247 3-5
143 304 4-7
203 444 5-8

C
141/4
151/2
173/4
18
18

H
4
57/8
97/8
97/8
97/8

 Type 48

5
803 /8

lbs
36
47
61
62
63

4.30

SELECTION TABLE
OD 10.75- 273mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 10.75 (ND 250/10), types 42, 43, 44, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950
42 27 19 1.40 1.05 0.75

985 1040 1075 1110F

d2
0.79

E
7

B
23/8

lbs
10

load
group
3-4

lbs
28
28
24

load
group
1-3
3-6
3-6

lbs
22
46
22
35
56
29
42
60

load
group
4-6
5-8
C-4
4-6
5-8
C-4
4-6
5-8

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


210 480 660 840 930 950
Type
43 27 18 2.05 2.00 1.90
43 27 19 6.50 4.00 3.10
2.90 1.95
43 27 29

permissible load
210
480 660
Type
4.7 3.5
44 27 12 5.8
44 27 13 13.2 12.1 9.4
44 27 31
44 27 32
10.7
44 27 33
44 27 41
44 27 42
44 27 43

(lbs x 1000)
840 930 950

2.0
5.6
8.9

1.9
5.1
8.5

1.9
4.9
7.8

985 1040 1075 1110F

985 1040 1075 1110F

1.7
4.0
6.5

11.0

1.1
2.4
4.0
1.7
4.4
7.4

1.3
3.3
5.3

1.1
2.4
4.0

B
d1
E
0.63 131/2 23/4
0.95 131/2 23/4
0.95 161/4 23/4

d3
1.34
1.80
0.81
1.34
1.80
0.81
1.34
1.80

E
131/2
141/4
163/4
163/4
163/4
163/4
163/4
163/4

B
27/8
43/8
35/8
33/4
43/4
41/8
41/2
51/8

 Type 46

 Type 48

80 35/8

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 9851040 1075 1110F d3
1.00
4.2711 7.8 6.2 4.4
1.34
4. 27 12 11.9 9.4 6.7
9.2 8.0 5.8
1.00
4. 27 21
12.1 11.2 8.0
1.34
4. 27 22
4.4 3.3 1.7
1.00
4. 27 31
9.2 7.8 5.6 3.3
1.00
4. 27 32
13.2 11.0 8.0 4.7
1.60
4. 27 33
22.4 18.8 13.7 8.0
1.80
4. 27 34
3.1 2.2 1.7 1.00
4. 27 41
6.0 4.4 3.3 1.00
4. 27 42
8.5 6.2 4.7 1.60
4. 27 43
14.6 11.0 8.0 1.80
4. 27 44
 Weights for type 46 - for type 48 approx. 22% less.

permissible load (lbs


210 480 660 840
Type
49 27 13 1.90 1.60 1.55
49 27 14 3.55 3.10 2.90
3.40 3.15
49 27 25
7.20
49 27 35
49 27 45

4.31

EK
13/8
13/4
13/4
2
11/4
2
2
23/4
11/4
2
2
23/4

x 1000)
930 950 985 1040 1075 1110F

ER
41/8
51/8
51/2
57/8
43/4
57/8
61/4
71/4
51/2
67/8
61/2
81/8

E
93/8
111/4
2.25
151/4
5.40 4.75 3.40 2.00
151/4
3.82 2.47 2.00 151/4

L
min. max.
211/2 451/2
211/2 451/2
233/4 511/2
233/4 511/2
233/4 551/2
233/4 551/2
233/4 551/2
233/4 551/2
231/2 55
231/2 55
231/2 55
231/2 55

A
93/4
105/8
131/2
133/4
133/4

B
61/4
63/4
9
9
9

lbs
load
min. max. group
61 125 3-5
72 157 4-6
69 163 3-5
88 213 4-6
70 145 3-5
95 209 3-5
121 264 4-7
181 381 5-8
82 167 3-5
115 248 3-5
146 307 4-7
212 453 5-8

C
141/4
151/2
173/4
18
18

H
4
57/8
97/8
97/8
97/8

lbs
36
47
61
62
63

SELECTION TABLE
OD 12.75- 323.9mm
Pipe clamps, clamp bases, OD 12.75 (ND 300/12), types 42, 43, 44, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950
42 32 19 1.25 0.90 0.65

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)
E
81/8

B lbs
23/8 12

load
group
3-4

d1
E
0.63 143/4
0.95 143/4
0.95 171/4

B lbs
31/8 35
31/8 35
23/4 33

load
group
1-3
3-6
3-6

985 1040 1075 1110F d2


0.79

Heat resistant materials see page 4.3

Type 210
43 32 18 2.05
43 32 19 6.70
43 32 29

permissible load (lbs x 1000)


480 660 840 930 950
2.00 1.90
4.90 3.55
4.00 3.80 2.45

Type
210
44 32 12 8.3
44 32 13 15.7
44 32 31
44 32 32
44 32 33
44 32 41
44 32 42
44 32 43

permissible load (lbs x 1000)


480 660 840 930 950 985 1040 1075 1110F d3
E
1.80 143/4
7.1 5.1
2.00 151/4
13.4 11.2
1.00 181/2
4.7 4.4 4.2 3.8 2.2
1.60 181/2
8.3 7.8 7.1 6.0 3.8
1.80 181/2
15.7 13.4 13.0 12.1 10.5 6.5
4.4 3.3 2.2 1.00 181/2
7.4 5.3 3.8 1.60 181/2
13.3 12.3 9.2 6.5 1.80 181/2

permissible load (lbs x 1000)


480 660 840 930 950 985 1040
5.1 3.8
9.4 6.7
13.9 10.3
6.0 4.4
13.4 11.4 8.3
18.6 15.7 11.4
6.2 4.7 2.6
14.1 11.4 8.5 4.9
19.1 15.5 11.4 6.7
24.7 21.3 15.7 8.7
32.5 26.7 19.7 11.4
4.7
8.9
12.1
15.7
20.9

Type 210
4.3211 6.7
4. 32 12 11.9
4. 32 13 18.8
4. 32 21
4. 32 22
4. 32 23
4. 32 31
4. 32 32
4. 32 33
4. 32 34
4. 32 35
4. 32 41
4. 32 42
4. 32 43
4. 32 44
4. 32 45
 Weights for type 46 - for type 48 approx. 22%

985

1040 1075 1110F

L
1075 1110F d3
1.00
1.34
1.60
1.00
1.34
1.80
1.00
1.60
1.80
1.80
2.00
3.5 2.6 1.00
6.5 4.9 1.60
8.9 6.7 1.80
11.9 8.7 1.80
15.7 11.4 2.00

EK
13/8
11/2
21/4
11/4
11/4
11/4
2
2
2
2
2
2
2
2
2
2

ER
43/4
51/2
53/8
43/4
57/8
61/4
57/8
71/8
75/8
81/8
77/8
61/2
71/8
81/4
87/8
91/4

min.
231/2
231/2
231/2
271/2
271/2
271/2
273/4
273/4
273/4
273/4
311/2
271/2
271/2
271/2
271/2
311/2

B
31/8
41/2
43/8
41/2
61/2
41/2
51/8
63/4

lbs
36
64
44
60
107
49
68
116

load
group
5-8
6-9
3-5
5-7
5-8
3-5
5-7
5-8

lbs
load
max. min. max. group
70 128 3-5
471/2
97 176 4-6
471/2
471/2 133 239 5-7
74 137 3-5
511/2
511/2 109 206 4-6
511/2 143 266 5-8
551/2 101 189 3-5
551/2 153 286 4-7
551/2 188 360 5-8
551/2 225 429 5-8
551/2 295 510 6-9
123 235 3-5
55
185 341 4-7
55
218 423 5-8
55
258 499 5-8
55
344 598 6-9
55

 Type 46

 Type 48

9345/8

less.

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F E
A
B
C
49 32 13 2.90 2.50 2.20
101/4 101/8 7 143/4
49 32 14 4.50 3.80 3.60
141/4 105/8 9 151/2
49 32 25
4.45 4.00 2.90
161/4 131/2 93/4 173/4
49 32 35
7.85 7.20 6.30 4.70 2.70
161/4 133/4 10 18
49 32 45
4.95 3.60 2.70 161/4 133/4 10 18

H
4
77/8
97/8
97/8
97/8

lbs
41
65
67
69
72

4.32

SELECTION TABLE
OD 14- 355.6mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 14 (ND 350/14), types 42, 43, 44, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950 985
42 36 19 1.15 0.85 0.60

B
E
83/4 23/8

lbs
13

load
group
3-4

B
1075 1110F d1
E
0.63 151/4 31/2
0.95 151/4 31/2
0.95 181/2 31/2

lbs
42
42
45

load
group
1-3
3-6
3-6

lbs
45
71
47
70
113
53
72
120

load
group
6-8
6-9
3-5
5-7
5-8
3-5
5-7
5-8

1040 1075 1110F d2


0.79

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


210 480 660 840 930 950
43 36 18 2.05 2.00 1.90
43 36 19 6.95 5.15 3.55
43 36 29
4.90 4.45 2.90
Type

permissible load (lbs


Type
210 480 660 840
44 36 12 9.8 8.5 6.2
44 36 13 15.7 13.4 11.9
44 36 31
4.7
44 36 32
8.7
44 36 33
15.7 13.4
44 36 41
44 36 42
44 36 43

985 1040

x 1000)
930 950

985 1040 1075 1110F d3


1.80
2.00
1.00
4.4 4.2 3.8
2.2
1.60
8.3 7.8 6.2
3.8
1.80
13.0 12.1 10.5
6.5
2.2 1.00
4.4 3.3
3.8 1.60
7.4 5.3
6.5 1.80
13.3 12.3 9.4

 Type 46

 Type 48

5
93 4 /8

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F d3
1.34
4.3611 8.3 6.5 4.7
1.34
4. 36 12 14.8 11.2 8.5
1.80
4. 36 13 20.8 16.4 11.9
5.3 3.8
1.00
4. 36 21
7.4 5.3
1.34
4. 36 22
16.8 14.6 10.5
1.60
4. 36 23
21.1 18.0 13.2
2.00
4. 36 24
5.3 3.8 2.2
1.00
4. 36 31
7.1 5.3 3.1
1.34
4. 36 32
15.0 12.5 9.2 5.3
1.60
4. 36 33
25.3 21.3 15.5 8.9
1.80
4. 36 34
37.3 30.3 22.4 13.2
2.00
4. 36 35
4.0 2.9 2.2 1.00
4. 36 41
5.6 4.2 3.1 1.34
4. 36 42
9.6 7.1 5.3 1.60
4. 36 43
16.1 12.1 8.9 1.80
4. 36 44
24.0 17.9 13.2 2.00
4. 36 45
 Weights for type 46 - for type 48 approx. 23% less.

L
EK
13/8
11/2
21/2
11/4
11/2
11/2
13/4
11/2
2
21/2
21/2
23/4
11/2
2
21/2
21/2
23/4

ER
43/4
51/8
53/4
41/2
51/2
61/8
61/4
53/8
61/4
71/8
81/8
9
61/8
63/4
71/2
91/2
95/8

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F E
49 36 13 4.90 4.25 4.00
11
49 36 14 6.05 5.15 4.90
147/8
49 36 25
5.80 5.20 3.80
167/8
49 36 35
10.10 9.20 8.10 5.85 3.40
183/4
49 36 45
6.30 4.72 3.40 183/4

4.33

E
153/4
161/2
191/8
191/8
191/8
191/8
191/8
191/8

min.
271/2
271/2
271/2
273/4
273/4
311/2
311/2
273/4
273/4
311/2
311/2
311/2
271/2
271/2
311/2
311/2
311/2

A
123/8
121/2
153/4
16
16

max.
511/2
511/2
511/2
551/2
551/2
551/2
551/2
591/2
591/2
591/2
591/2
591/2
59
59
59
59
59

B
33/8
41/2
43/8
43/4
61/2
41/2
51/8
63/4

lbs
load
min. max. group
105 166 4-6
131 228 4-6
154 283 6-8
67 144 3-5
103 172 4-6
161 294 5-7
180 342 6-9
103 195 3-5
128 245 4-6
190 337 4-7
261 482 5-8
355 620 6-9
123 228 3-5
150 286 4-6
231 407 4-7
302 561 5-8
414 747 6-9

B
9
91/4
101/4
11
11

C
H lbs
59
171/2 4
18
77/8 61
20
97/8 74
3
/
20 4 117/8 103
203/4 117/8 103

SELECTION TABLE
OD 14.50- 368mm

Twice the specified load is possible


by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 14.50 (ND 350/14), types 42, 43, 44, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950
42 37 19 1.10 0.85 0.60

985

Temperature up to
1200F see page 4.46

1040 1075 1110F d2


0.79

E
9

B
23/8

lbs
13

load
group
3-4

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type
210 480 660 840 930 950
43 37 18 2.05 2.00 1.90
43 37 19 6.70 4.90 3.55
43 37 29
4.90 4.45 2.90

B
985 1040 1075 1110F d1
E
0.63 151/2 31/2
0.95 151/2 31/2
0.95 183/4 31/2

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985
44 37 12 9.8 8.5 6.0
44 37 13 15.7 13.4 11.9
44 37 31
4.7 4.4 4.2 3.8
44 37 32
8.7 8.3 7.8 6.2
44 37 33
16.0 13.4 13.0 12.1 10.5
44 37 41
44 37 42
44 37 43
13.3

1040 1075 1110F

2.2
4.0
6.5
4.4
7.4
12.3

3.3
5.3
9.4

2.2
4.0
6,5

permissible load (lbs x 1000)


480 660 840 930 950 985 1040 1075 1110F d3 EK
6.5 4.7
1.34 13/8
11.2 8.5
1.34 11/2
16.1 11.9
1.80 21/2
5.3 3.8
1.00 11/4
7.4 5.3
1.34 11/2
16.8 14.6 10.5
1.60 11/2
21.1 18.0 13.2
1.80 13/4
1.00 11/2
5.3 3.8 2.2
1.34 2
7.1 5.3 3.1
15.5 12.5 9.2 5.3
1.60 21/2
25.3 21.3 15.5 8.9
1.80 21/2
37.3 30.3 22.4 13.2
2.00 23/4
4.0 2.9 2.2 1.00 11/2
5.6 4.2 3.1 1.34 2
9.6 7.1 5.3 1.60 21/2
16.1 12.1 8.9 1.80 21/2
23.8 17.9 13.2 2.00 23/4

Type
210
4.3711 8.3
4. 37 12 14.8
4. 37 13 20.8
4. 37 21
4. 37 22
4. 37 23
4. 37 24
4. 37 31
4. 37 32
4. 37 33
4. 37 34
4. 37 35
4. 37 41
4. 37 42
4. 37 43
4. 37 44
4. 37 45
 Weights for type 46 - for type 48 approx. 23% less.

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985
49 37 13 4.90 4.25 4.00
49 37 14 6.30 5.40 5.15
49 37 25
5.80 5.40 4.00
49 37 35
10.30 9.45 8.30 6.05
49 37 45

1040 1075 1110F

3.60
6.74 4.95

E
111/4
151/8
171/8
19
3.60 19

load
group
1-3
3-6
3-6

E
153/4
161/2
191/4
191/4
191/4
191/4
191/4
191/4

load
B lbs group
33/8 45 6-8
41/2 71 6-9
43/8 47 3-5
43/4 69 5-7
61/2 115 5-8
41/2 54 3-5
51/8 73 5-7
63/4 122 5-8

L
min. max.
271/2 511/2
271/2 511/2
271/2 511/2
273/4 551/2
273/4 551/2
311/2 551/2
311/2 551/2
291/2 591/2
291/2 591/2
291/2 591/2
291/2 591/2
331/2 591/2
291/2 59
291/2 59
291/2 59
291/2 59
331/2 59

lbs
load
min. max. group
108 169 4-6
135 232 4-6
159 287 6-8
70 144 3-5
90 175 4-6
152 295 5-7
184 340 6-8
108 198 3-5
135 243 4-6
185 343 4-7
259 488 5-8
370 630 6-9
130 231 3-5
159 291 4-6
223 401 4-7
302 568 5-8
437 756 6-9

d3
1.80
2.00
1.00
1.60
1.80
1.00
1.60
1.80

ER
43/4
51/8
53/4
41/2
51/2
61/8
61/4
53/8
61/4
71/8
85/8
9
61/8
63/4
71/2
91/2
95/8

lbs
41
41
45

A
B
123/8 9
121/2 91/2
153/4 101/4
16 111/2
16 111/2

C
171/2
18
20
203/4
203/4

 Type 46

 Type 48

9345/8

H lbs
4
59
77/8 62
97/8 74
117/8 107
117/8 107

4.34

SELECTION TABLE
OD 16- 406.4mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 16 (ND 400/16), types 42, 43, 44, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950
42 41 19 1.75 1.40 1.00

985 1040

1075 1110F

d2
0.95

E
10

B
23/4

lbs
21

load
group
3-5

B
4
4
4

lbs
51
51
54

load
group
1-3
3-6
3-6

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type
210 480 660 840 930 950
43 41 18 2.05 2.00 1.90
43 41 19 6.95 5.15 3.55
43 41 29
4.90 4.45 2.90

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985
44 41 12 13.2 10.1 8.3
44 41 13 19.3 17.0 13.7
44 41 22
5.8 5.3
44 41 23
10.7 8.5
44 41 31
4.2 3.8
44 41 35
8.9 8.5 7.6
44 41 36
14.8 14.1 13.0
44 41 41
44 41 45
44 41 46
21.8

 Type 46

 Type 48

118
55/8

1040 1075 1110F d1


E
0.63 17
0.95 17
0.95 193/4

1040 1075 1110F

2.2
5.1
8.5
4.2
9.2
13.9

3.1
6.7
10.3

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F d3
1.34
4.4111 9.8 7.8 5.6
4. 41 12 16.1 12.3 9.2
1.60
4. 41 13 24.7 18.8 14.1
1.80
4. 41 21
6.2 4.4
1.00
4. 41 22
8.7 6.2
1.34
4. 41 23
20.0 17.3 12.3
1.60
4. 41 24
25.0 21.3 15.5
1.80
4. 41 31
1.00
6.2 4.4 2.6
4. 41 32
1.60
10.1 7.8 4.4
4. 41 33
17.7 14.6 10.7 6.2
1.80
4. 41 34
25.1 21.3 15.5 8.9
1.80
4. 41 35
43.5 36.0 26.5 15.5
2.00
4. 41 41
4.7 3.5 2.6 1.00
4. 41 42
8.0 6.0 4.4 1.60
4. 41 43
11.2 8.5 6.2 1.80
4. 41 44
16.1 12.1 8.9 1.80
4. 41 45
28.1 21.1 15.5 2.00
 Weights for type 46 - for type 48 approx. 21% less.

Type
49 41 13
49 41 14
49 41 25
49 41 35
49 41 45

4.35

985

210
5.8
10.7

permissible load (lbs x 1000)


480 660 840 930 950 985
4.9 4.7
8.5 7.8
8.3 5.8 4.7
13.5 11.7 10.3 7.6

2.2
5.1
7.6

6.7

E
171/2
173/4
193/4
193/4
201/2
201/2
201/2
201/2
201/2
201/2

L
EK ER min.
11/4 61/8 311/2
11/2 61/4 311/2
21/4 67/8 311/2
11/2 53/4 311/2
11/2 57/8 311/2
2
71/8 331/2
1
2 /2 71/8 331/2
13/4 61/4 311/2
2
71/8 311/2
23/4 77/8 311/2
23/4 85/8 311/2
31/4 101/4 351/2
13/4 67/8 331/2
2
81/8 331/2
3
2 /4 87/8 331/2
23/4 87/8 331/2
31/4 101/2 351/2

1040 1075 1110F

4.5
9.0

d3
2.00
2.40
1.60
2.00
1.00
1.80
2.00
1.00
1.80
2.00

4.5

E
117/8
157/8
173/4
197/8
197/8

A
113/4
121/2
157/8
161/8
161/8

max.
551/2
551/2
551/2
591/2
591/2
591/2
591/2
631/2
631/2
631/2
631/2
631/2
63
63
63
63
63

B
101/4
91/2
103/4
113/4
113/4

B
35/8
51/4
45/8
51/4
43/8
53/4
57/8
41/2
53/4
71/4

load
lbs group
58 6-9
86 7-10
57 5-7
88 6-9
51 3-5
102 5-8
147 6-9
58 3-5
130 5-8
204 6-9

lbs
min. max.
138 211
168 286
228 362
104 192
136 223
207 349
237 414
137 244
194 343
252 448
310 550
465 820
170 300
238 417
291 520
366 645
551 939

load
group
4-6
5-7
6-8
3-5
4-6
5-7
6-8
3-5
4-7
5-8
5-8
6-9
3-5
4-7
5-8
5-8
6-9

C
H
173/4 4
19
77/8
21
97/8
3
/
21 4 117/8
213/4 117/8

lbs
86
91
109
146
146

SELECTION TABLE
OD 16.50- 419mm

Twice the specified load is possible


by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 16.50 (ND 400/16), types 42, 43, 44, 46, 48, 49
permissible load(lbs x 1000)
210 480 660 840 930 950
42 42 19 1.75 1.35 0.95
Type

Temperature up to
1200F see page 4.46

985 1040 1075 1110F

d2
E
B
0.95 101/4 23/4

lbs
21

load
group
3-5

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


210 480 660 840 930 950
43 42 18 2.05 2.00 1.90
43 42 19 6.70 5.15 3.55
43 42 29
4.90 4.45 2.90
Type

985 1040

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040
44 42 12 13.2 10.1 8.3
44 42 15 33.7 24.7 18.4
44 42 22
5.8 5.3
44 42 25
12.5 11.2
44 42 31
4.2 3.8 2.2
44 42 35
8.9 7.6 5.3
44 42 36
15.2 14.6 13.0 8.7
44 42 41
4.2
44 42 45
9.2
44 42 46
22.0 13.9
Type

Type

1075 1110F d1
E
0.63 17
0.95 17
0.95 193/4

1075 1110F d3
2.00
2.40
1.60
2.00
1.00
1.80
2.00
3.1 2.2 1.00
6.7 5.1 1.80
10.3 7.6 2.00

permissible load (lbs x 1000)


480 660 840 930 950 985 1040 1075 1110F d3 EK ER
7.8 5.6
1.34 11/4 61/8
12.3 9.2
1.60 11/2 61/4
18.8 14.1
1.80 21/4 67/8
6.2 4.4
1.00 11/2 53/4
8.7 6.2
1.34 11/2 57/8
20.0 17.3 12.3
1.60 2
71/8
25.0 21.3 15.5
1.80 21/2 71/8
6.2 4.4 2.6
1.00 13/4 61/4
10.1 7.8 4.4
1.60 2
71/8
17.7 14.6 10.7 6.2
1.80 23/4 77/8
25.3 21.3 15.5 8.9
1.80 23/4 85/8
43.5 36.0 26.5 15.5
2.00 31/4 101/4
4.7 3.5 2.6 1.00 13/4 67/8
81/8
8.0 6.0 4.4 1.60 2
11.2 8.5 6.2 1.80 23/4 87/8
16.1 12.1 8.9 1.80 23/4 87/8
28.1 21.1 15.5 2.00 31/4 101/2

210
4.4211 9.8
4. 42 12 16.1
4. 42 13 24.7
4. 42 21
4. 42 22
4. 42 23
4. 42 24
4. 42 31
4. 42 32
4. 42 33
4. 42 34
4. 42 35
4. 42 41
4. 42 42
4. 42 43
4. 42 44
4. 42 45
 Weights for type 46 - for type 48 approx. 21% less.

Type
49 42 13
49 42 14
49 42 25
49 42 35
49 42 45

permissible load (lbs


210 480 660 840
7.4 5.8 4.9
10.7 8.5 7.8
8.3
6.5
13.5

x 1000)
930 950 985 1040 1075 1110F

5.2
12.8 11.4 8.5 4.9
9.4

7.2

4.9

E
121/4
161/8
181/8
201/8
201/8

E
171/2
18
193/4
193/4
203/4
203/4
203/4
203/4
203/4
203/4

L
min.
311/2
311/2
311/2
311/2
311/2
331/2
331/2
311/2
311/2
311/2
351/2
351/2
311/2
311/2
311/2
351/2
351/2

A
115/8
121/2
157/8
161/8
161/8

B
4
4
4

max.
551/2
551/2
551/2
591/2
591/2
591/2
591/2
631/2
631/2
631/2
631/2
631/2
63
63
63
63
63

B
91/2
91/2
103/4
113/4
113/4

B
35/8
63/8
45/8
53/4
43/8
53/4
57/8
41/2
53/4
71/4

lbs
51
51
54

load
group
1-3
3-6
3-6

lbs
59
148
58
104
52
101
150
59
130
215

load
group
6-9
7-10
5-7
6-9
3-5
5-8
6-9
3-5
5-8
6-9

lbs
min. max.
141 215
173 286
237 386
106 190
139 224
201 383
242 433
140 248
195 347
258 450
330 555
475 830
172 305
236 412
298 527
392 653
562 951

load
group
4-6
5-7
6-8
3-5
4-6
5-7
6-8
3-5
4-7
5-8
5-8
6-9
3-5
4-7
5-8
5-8
6-9

 Type 46

 Type 48

55/8
118

lbs
H
C
68
161/2 4
77/8 92
19
97/8 110
21
3
/
21 4 117/8 146
213/4 11 7/8 146

4.36

SELECTION TABLE
OD 18- 457.2mm

Temperature up to
1200F see page 4.46

Pipe clamps, clamp bases, OD 18 (ND 450/18), types 42, 43, 44, 46, 48, 49
permissible load (lbs x 1000)
210 480 660 840 930 950
42 46 19 1.70 1.30 0.90
Type

Twice the specified load is possible


by use of type 77 (see page 4.55)

985 1040 1075 1110F d2


0.95

E
B
11 23/4

lbs
23

load
group
3-5

lbs
53
53

load
group
1-3
3-6

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


210 480 660 840 930 950
43 46 18 2.05 2.00 1.90
43 46 19 6.50 4.70 3.35
Type

Type

210
44 46 12 13.2
44 46 13 15.7
44 46 15 33.7
44 46 22
44 46 23
44 46 25
44 46 31
44 46 32
44 46 35
44 46 36
44 46 41
44 46 42
44 46 45
44 46 46
Type
 Type 46

 Type 48

118
55/8

permissible load (lbs x 1000)


480 660 840 930 950 985
11.2 8.5
14.0 11.0
24.7 18.4
4.9 4.4
9.8 8.3
12.3 11.2
3.1 2.9
7.1 6.5
14.0 13.4 12.8
22.6 22.4 21.1

26.3
480
7.8
10.3
20.6
25.1

1040 1075 1110F

2.2
4.0
7.8
13.0
4.0 3.1 2.2
7.1 5.3 4.0
13.9 10.3 7.6
20.2 14.8 11.0

permissible load (lbs x 1000)


660 840 930 950 985 1040 1075 1110F
5.6
7.4
15.5
19.7
7.6 5.3
12.1 8.9
29.0 24.4 18.0
33.4 28.0 20.2
10.3 7.6 4.4
12.1 8.9 5.1
25.3 21.3 15.5 8.9
51.0 41.5 30.7 17.9
57.7 47.1 34.6 20.2
8.0 6.0 4.4
9.2 6.9 5.1
16.1 12.1 8.9
32.5 24.5 17.9
36.6 27.4 20.2

4.4611
4. 46 12
4. 46 13
4. 46 14
4. 46 21
4. 46 22
4. 46 23
4. 46 24
4. 46 31
4. 46 32
4. 46 33
4. 46 34
4. 46 35
4. 46 41
4. 46 42
4. 46 43
4. 46 44
4. 46 45
 Weights for type 46 - for type 48 approx. 24% less.

Type
49 46 13
49 46 14
49 46 25
49 46 35
49 46 45

4.37

210
10.1
13.2
27.0
33.7

985 1040 1075 1110F d1


E
0.63 173/4
0.95 173/4

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040
8.0 7.1 5.1
15.0 11.4 8.3
9.0 7.6 6.1
15.0 14.3 13.7 10.1 5.8
10.8

d3
1.34
1.60
1.80
2.00
1.34
1.60
1.80
2.00
1.60
1.80
1.80
2.00
2.40
1.60
1.80
1.80
2.00
2.40

EK
13/8
11/2
2
21/2
13/4
2
21/4
21/4
2
2
21/2
23/4
31/4
2
2
21/2
23/4
31/4

1075 1110F

8.1

5.8

d3
2.00
2.00
2.40
1.60
2.00
2.00
1.00
1.80
2.00
2.00
1.00
1.80
2.00
2.00

ER
57/8
61/8
63/4
71/4
61/4
63/4
71/4
77/8
71/8
71/2
87/8
95/8
97/8
75/8
81/4
91/4
111/2
111/2

E
13
167/8
187/8
203/4
203/4

B
4
4

E
181/2
181/2
19
211/4
211/4
211/4
22
22
22
22
22
22
22
22

L
min.
331/2
331/2
331/2
331/2
331/2
331/2
371/2
371/2
351/2
351/2
351/2
391/2
391/2
351/2
351/2
351/2
391/2
391/2

A
137/8
141/8
157/8
161/8
161/8

B
43/8
41/2
63/8
33/4
43/4
51/2
4
51/4
57/8
81/4
41/2
51/2
71/4
81/2

max.
571/2
571/2
571/2
571/2
631/2
631/2
631/2
631/2
671/2
671/2
671/2
671/2
671/2
67
67
67
67
67

B
91/2
101/4
111/2
123/4
123/4

load
lbs group
69 6-9
83 7-9
153 7-10
54 5-7
82 6-9
105 6-9
58 3-5
93 5-8
154 6-9
260 6-9
63 3-5
97 5-8
214 6-9
316 6-9

lbs
min. max.
161 252
176 293
303 411
315 515
149 235
193 340
320 545
345 555
233 391
270 449
365 610
620 990
660 1070
287 470
315 538
439 726
710 1175
796 1287

load
group
4-6
5-7
6-8
6-9
4-6
5-7
6-8
7-9
4-7
5-8
5-8
6-9
7-10
4-7
5-8
5-8
6-9
7-10

C
H lbs
19
4
82
193/4 77/8 113
21
97/8 117
3
21 /4 117/8 156
213/4 117/8 156

SELECTION TABLE
OD 20 - 508mm

Twice the specified load is possible


by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 20 (ND 500/20), types 42, 44, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950
42 51 19 1.60 1.20 0.85

Temperature up to
1200F see page 4.46

E
12

B
23/4

lbs
25

load
group
3-5

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F d3
E
44 51 14 2.2 1.7 1.5
0.81 193/4
44 51 15 6.5 5.3 3.8
1.34 193/4
44 51 16 12.8 10.3 7.8
2.00 193/4
44 51 17 22.0 16.1 13.4
2.40 193/4
44 51 18 44.0 33.7 26.9
2.80 201/2
44 51 25
1.00 221/2
2.9 2.2
44 51 26
1.60 221/2
4.9 4.4
44 51 27
2.00 221/2
10.1 8.9
44 51 28
2.40 221/2
21.3 18.0
44 51 35
1.00 231/4
3.8
3.5 2.2
44 51 36
1.80 231/4
8.0
7.4 4.4
44 51 37
2.00 231/4
18.6 17.7 14.0 8.9
44 51 38
2.40 231/4
29.4 24.7 21.1 13.4
44 51 45
1.00 231/4
4.2 3.3
2.2
44 51 46
1.80 231/4
8.5 6.5
4.4
44 51 47
2.00 231/4
14.1 10.3
7.8
44 51 48
40.7 27.2 20.2 14.6 2.40 231/4

B
31/8
31/8
35/8
63/8
83/4
4
4
43/4
61/2
5
53/4
73/8
73/4
51/8
53/4
75/8
91/4

lbs
58
63
83
155
275
63
71
97
172
84
113
183
260
94
141
240
412

load
group
1-4
4-6
6-9
7-10
8-30
3-5
5-7
6-9
7-10
3-5
5-8
6-9
7-10
3-5
5-8
6-9
7-10

985 1040 1075 1110F

d2
0.95

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F d3
4.5111 10.1 7.8 5.6
1.34
4. 51 12 15.2 11.4 8.3
1.60
4. 51 13 27.0 20.6 15.0
1.80
4. 51 14 38.2 28.0 22.4
2.00
4. 51 21
8.9 6.5
1.34
4. 51 22
12.1 8.9
1.60
4. 51 23
28.5 24.4 17.7
1.80
4. 51 24
35.0 30.1 22.0
2.40
4. 51 31
1.60
10.1 7.8 4.4
4. 51 32
25.3 12.1 8.9 5.1
1.80
4. 51 33
51.0 20.2 15.5 8.9
1.80
4. 51 34
63.5 41.5 30.7 18.0
2.00
4. 51 35
2.40
51.6 38.2 22.4
4. 51 41
8.0 6.0 4.4 1.60
4. 51 42
9.2 6.9 5.1 1.80
4. 51 43
16.1 12.1 8.9 1.80
4. 51 44
32.5 24.5 17.9 2.00
4. 51 45
40.9 30.7 22.4 2.40
 Weights for type 46 - for type 48 approx. 23% less.
permissible load
Type
210 480 660 840
49 51 13 10.1 8.0 5.8
49 51 14 18.4 13.9 10.1
49 51 25
11.9 9.7
49 51 35
18.6
49 51 45

EK
13/8
11/2
21/2
21/2
2
21/2
21/2
21/2
21/2
23/4
31/4
31/4
31/2
21/2
23/4
31/4
31/4
31/2

(lbs x 1000)
930 950 985 1040 1075 1110F

7.6
17.7 16.6 12.3 7.2
15.3 11.2

7.2

ER
61/4
67/8
67/8
71/8
63/4
71/8
77/8
85/8
77/8
77/8
9
101/2
113/4
81/4
87/8
97/8
121/2
121/2

min.
351/2
351/2
351/2
351/2
371/2
371/2
411/2
411/2
391/2
391/2
391/2
411/2
411/2
391/2
391/2
391/2
411/2
411/2

E
14
177/8
213/4
213/4
213/4

L
max.
591/2
591/2
591/2
591/2
651/2
651/2
651/2
651/2
711/2
711/2
711/2
711/2
711/2
71
71
71
71
71

A
141/8
141/8
161/8
161/4
161/4

load
lbs
min. max. group
195 279 4-6
215 339 5-7
386 472 6-8
380 600 6-9
183 285 4-6
225 340 5-7
365 555 6-8
430 620 7-10
272 436 4-7
320 505 5-8
425 690 5-8
670 1105 6-9
785 1255 7-10
335 528 4-7
377 600 5-8
511 844 5-8
809 1310 6-9
957 1528 7-10

B
91/2
11
13
13
13

C
193/4
193/4
215/8
223/4
223/4

H
4
77/8
117/8
117/8
117/8

 Type 46

 Type 48

144
63/4

lbs
96
122
140
185
192

4.38

SELECTION TABLE
OD 22 - 558.8mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 22 (ND 550/22), types 42, 44, 46, 48, 49

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F d2
B
E
42 56 19 4.00 2.90 2.20
1.20 133/4 31/2

lbs
53

load
group
5-6

lbs
77
94
106
164
290
75
105
113
184
116
200
265
370
152
269
331
458

load
group
3-6
5-8
6-9
7-10
8-30
4-6
6-9
6-9
7-10
5-8
6-9
7-10
7-10
5-8
6-9
7-10
7-10

Heat resistant materials see page 4.3

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985
44 56 14 4.4 3.8 3.3
44 56 15 9.8 7.8 5.8
44 56 16 16.6 13.4 10.1
44 56 17 22.4 17.3 13.9
44 56 18 44.0 35.9 26.9
44 56 25
4.0
4.2
44 56 26
8.9
10.1
44 56 27
11.9 11.2
44 56 28
20.2 18.0
44 56 35
8.0 7.4
44 56 36
18.6 17.7 14.0
44 56 37
27.0 23.5 18.4
44 56 38
34.8 33.7 29.2
44 56 45
44 56 46
44 56 47
31.0
44 56 48
45.0

 Type 46

 Type 48

144

63/4

1040 1075 1110F

4.4
8.9
12.3
18.0
8.9 6.5
14.1 10.5
20.2 14.8
28.5 21.1

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F d3
4.5611 10.1 7.6 5.6
1.34
4. 56 12 15.2 11.6 8.5
1.60
4. 56 13 29.2 21.7 17.3
2.00
4. 56 14 46.5 34.3 27.4
2.00
4. 56 21
9.2 6.7
1.34
4. 56 22
12.1 8.9
1.60
4. 56 23
29.2 24.7 18.0
2.00
4. 56 24
43.5 37.0 27.0
2.00
4. 56 31
1.60
11.9 8.5 4.9
4. 56 32
1.80
15.7 11.4 6.7
4. 56 33
1.80
20.2 15.5 8.9
4. 56 34
51.0 41.5 30.7 17.9
2.00
4. 56 35
76.8 63.0 45.0 27.0
2.40
4. 56 41
8.7 6.5 4.9 1.60
4. 56 42
12.1 8.9 6.7 1.80
4. 56 43
16.1 12.1 8.9 1.80
4. 56 44
32.5 24.5 17.9 2.00
4. 56 45
48.7 36.6 26.9 2.40
 Weights for type 46 - for type 48 approx. 25% less.

4.4
7.8
11.2
15.7

d3
1.34
1.80
2.00
2.40
2.80
1.34
2.00
2.00
2.40
1.80
2.00
2.40
2.40
1.80
2.00
2.40
2.40

EK ER
11/2 6 3/4
2
71/4
21/2 75/8
21/2 81/8
21/4 71/8
21/2 71/2
21/2 81/8
21/2 91/2
21/2 77/8
21/2 9
23/4 91/2
31/2 103/4
4 121/2
21/2 87/8
21/2 85/8
23/4 101/4
31/2 111/4
4 141/4

E
21
21
21
21
211/2
233/4
233/4
233/4
233/4
241/2
241/2
241/2
241/2
241/2
241/2
241/2
241/2

L
min.
371/2
371/2
371/2
371/2
391/2
391/2
431/2
431/2
431/2
431/2
431/2
431/2
471/4
431/2
431/2
431/2
431/2
47

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F
A
E
49 56 13 12.1 9.6 6.9
15 153/4
49 56 14 21.3 17.9 13.0
187/8 157/8
49 56 25
14.1 11.9 9.4
223/4 173/4
49 56 35
23.6 22.5 20.0 14.6 8.5
223/4 177/8
49 56 45
8.5
16.4 12.1
223/4 177/8

4.39

max.
611/2
611/2
611/2
611/2
671/2
671/2
671/2
671/2
75
75
75
75
75
75
75
75
75
75

B
33/8
41/4
41/2
63/8
83/4
4
43/4
51/4
61/2
51/2
73/8
73/4
85/8
53/4
75/8
81/8
95/8

lbs
min. max.
199 294
241 367
380 565
495 690
211 317
251 403
445 615
530 775
340 530
415 675
480 750
755 1220
1025 1515
412 641
507 773
593 932
915 1453
1260 1910

B
91/2
111/2
131/2
133/4
133/4

load
group
4-6
5-7
6-9
7-9
4-6
5-7
6-9
7-9
4-7
5-8
5-8
6-9
7-10
4-7
5-8
5-8
6-9
7-10

C
H
221/2 4
23
77/8
3
24 /8 117/8
25 117/8
251/2 117/8

lbs
160
202
206
257
267

SELECTION TABLE
OD 24 - 609.6mm
Pipe clamps, clamp bases, OD 24 (ND 600/24), types 42, 44, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950
42 61 19 3.80 2.90 2.05

Temperature up to
1200F see page 4.46

985 1040 1075 1110F

Twice the specified load is possible


by use of type 77 (see page 4.55)

d2
E
1.20 143/4

B
31/2

lbs
57

load
group
5-6

lbs
92
105
125
174
300
97
113
169
198
144
222
320
405
169
264
465
537

load
group
3-6
6-9
6-9
7-10
8-30
4-7
6-9
7-10
7-10
5-8
6-9
7-10
8-30
5-8
6-9
7-10
8-30

Heat resistant materials see page 4.3

Type
44 61 14
44 61 15
44 61 16
44 61 17
44 61 18
44 61 25
44 61 26
44 61 27
44 61 28
44 61 35
44 61 36
44 61 37
44 61 38
44 61 45
44 61 46
44 61 47
44 61 48

210
6.5
13.0
18.0
26.0
45.0

permissible load (lbs x 1000)


480 660 840 930 950 985 1040
5.3 4.4
10.1 7.8
14.6 10.7
19.5 16.4
37.0 26.9
4.4
4.9
8.5
9.4
14.6 12.3
20.2 18.4
8.5 7.4 4.4
17.5 13.7 8.7
25.8 23.5 19.1 13.4
39.3 36.0 29.8 20.2
8.5
13.9
34.2 25.8
53.1 34.8

1075 1110F

6.5
10.3
19.3
25.6

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F d3
4.6111 13.4 10.5 7.6
1.60
4. 61 12 20.2 15.5 11.4
1.80
4. 61 13 28.5 21.5 17.0
2.00
4. 61 14 41.7 31.0 25.0
2.00
4. 61 15 50.0 37.0 29.6
2.40
4. 61 21
12.8 9.4
1.60
4. 61 22
24.7 17.9
2.00
4. 61 23
40.4 36.0 27.0
2.00
4. 61 24
51.6 45.0 33.7
2.40
4. 61 31
12.0 8.7 4.9
1.60
4. 61 32
20.2 15.5 8.9
1.80
4. 61 33
27.6 20.2 11.9
1.80
4. 61 34
49.4 40.4 29.6 17.5
2.00
4. 61 35
76.4 63.0 45.0 26.9
2.40
4. 61 36
94.3 78.6 58.4 33.7
2.80
4. 61 41
8.7 6.7 4.9 1.60
4. 61 42
16.1 12.1 8.9 1.80
4. 61 43
21.5 16.1 11.9 1.80
4. 61 44
31.6 23.8 17.5 2.00
4. 61 45
48.7 36.6 26.9 2.40
4. 61 46
61.1 46.0 33.7 2.80
 Weights for type 46 - for type 48 approx. 26% less.

4.4
7.6
13.4
19.1
EK
11/2
13/4
2
21/4
21/2
21/2
21/2
21/2
23/4
21/2
23/4
31/2
31/2
41/4
41/4
21/2
23/4
31/2
31/2
41/4
41/2

d3
1.34
2.00
2.00
2.40
2.80
1.60
2.00
2.40
2.40
1.80
2.00
2.40
2.80
1.80
2.00
2.40
2.80

ER
71/4
75/8
71/2
81/8
9
71/2
85/8
91/4
101/2
85/8
91/4
11
111/4
123/4
141/4
9
103/4
11
111/2
14
141/4

E
22
22
22
22
223/4
251/2
251/2
251/2
251/2
27
27
27
27
27
27
27
27

L
min.
391/2
391/2
391/2
391/2
391/2
431/2
431/2
431/2
451/4
471/4
471/4
471/4
511/4
51 1/4
511/4
47
47
47
51
51
51

permissible load (lbs x 1000)


Type
A
210 480 660 840 930 950 985 1040 1075 1110F
E
49 61 13 14.0 13.0 10.7
18 153/4
49 61 14 23.6 17.9 13.0
197/8 157/8
49 61 25
14.6 13.7 10.8
233/4 173/4
49 61 35
24.2 22.9 22.0 17.0 10.1
233/4 177/8
49 61 45
18.7 13.9 10.1 233/4 177/8

max.
631/2
631/2
631/2
631/2
631/2
711/2
711/2
711/2
711/2
79
79
79
79
79
79
79
79
79
79
79
79

41/2
37/8
43/4
63/8
83/4
43/4
43/4
55/8
61/2
61/2
73/8
81/4
85/8
61/4
75/8
95/8
95/8

lbs
min. max.
270 386
337 477
435 615
540 720
605 855
285 454
460 650
565 840
710 1005
390 595
550 830
650 975
880 1325
1160 1665
1385 2000
470 701
670 1027
811 1203
1080 1573
1440 2114
1706 2506

B
103/4
121/4
141/4
141/2
141/2

C
H
221/2 57/8
23
77/8
3
24 /8 117/8
25 117/8
251/2 117/8

load
group
4-7
6-8
6-9
7-9
7-10
4-7
6-9
7-9
8-10
4-7
5-8
5-8
6-9
7-10
8-30
4-7
5-8
5-8
6-9
7-10
8-30

 Type 46

 Type 48

7/
7172
8

lbs
181
217
219
271
284

4.40

SELECTION TABLE
OD 26 - 660.4mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 26 (ND 650/26), types 42, 44, 46, 48, 49

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F d2
42 66 19 3.55 2.65 1.95
1.20
Type

Type

Heat resistant materials


see page 4.3

44 66 14
44 66 15
44 66 16
44 66 17
44 66 18
44 66 19
44 66 25
44 66 26
44 66 27
44 66 28
44 66 35
44 66 36
44 66 37
44 66 38
44 66 45
44 66 46
44 66 47
44 66 48

 Type 48

172
87/

480
6.2
9.8
14.6
21.3
30.3
54.0

permissible load (lbs x 1000)


660 840 930 950 985 1040
5.3
7.6
11.9
17.5
23.5
40.4
4.9 4.4
10.1 8.9
16.8 15.7
29.6 27.0
4.4
8.9 7.8
9.4
18.6 15.7
25.6 19.3 13.4
39.3 36.0 29.8 20.2
8.7
17.3
35.5 27.2
53.8 35.2

1075 1110F

6.5
13.0
19.7
25.8

permissible load (lbs x 1000)


660 840 930 950 985 1040 1075 1110F d3
4.6611
7.4
1.60
4. 66 12
11.4
1.80
4. 66 13
18.0
2.00
4. 66 14
28.0
2.40
4. 66 15
33.7
2.40
4. 66 21
14.1 10.1
1.60
4. 66 22
24.7 18.0
2.00
4. 66 23
42.6 36.0 27.0
2.00
4. 66 24
54.0 45.0 33.7
2.40

4. 66
31 von min. auf max. jeweils13.4
Sprnge
200mm.
10.5 5.6
1.60
4. 66 32
20.2 15.5 8.9
1.80
4. 66 33
1.80
34.8 28.0 20.6 12.3
4. 66 34
2.00
50.5 41.5 30.7 17.9
4. 66 35
2.40
76.4 63.0 45.0 26.9
4. 66 36
2.80
94.3 78.6 58.4 33.7
4. 66 41
10.1 7.6 5.6 1.60
4. 66 42
16.1 12.1 8.9 1.80
4. 66 43
22.2 16.8 12.3 1.80
4. 66 44
32.8 24.7 17.9 2.00
4. 66 45
49.0 36.8 26.9 2.40
4. 66 46
61.1 46.0 33.7 2.80

4.4
9.4
13.4
19.3

d3
1.60
2.00
2.00
2.40
2.80
2.80
1.60
2.00
2.40
2.80
1.80
2.00
2.40
2.80
1.80
2.00
2.40
2.80

E
24
24
24
24
24
25
263/4
263/4
263/4
263/4
271/2
271/2
271/2
271/2
271/2
271/2
271/2
271/2

ER
77/8
81/2
77/8
95/8
91/4
85/8
95/8
101/4
103/4
87/8
95/8
111/2
12
121/2
14
91/4
111/4
111/2
121/2
133/4
141/4

L
min.
411/2
411/2
411/2
411/2
411/2
491/4
491/4
491/4
51
491/4
491/4
491/4
491/4
531/4
531/4
49
49
49
49
53
53

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F
E
49 66 13 16.6 14.6 10.7
187/8
49 66 14 26.9 20.6 15.0
207/8
49 66 25
16.6 14.8 12.8
243/4
49 66 35
28.5 27.0 25.8 20.0 11.7
243/4
49 66 45
21.6 16.2 11.7 243/4

A
153/4
157/8
173/4
18
18

Type

 Type 46

210
7.8
12.5
18.4
28.7
40.2
68.3

B
E
153/4 31/2

210
13.4
20.2
30.3
48.3
57.5

480
10.3
15.7
22.4
34.8
42.6

EK
11/2
2
21/4
21/2
23/4
21/2
21/2
23/4
31/4
21/2
21/2
31/2
31/2
4
41/4
21/2
21/2
31/2
31/2
4
41/4

B
41/2
41/2
63/8
63/8
81/4
9
43/4
51/4
61/4
73/4
61/2
73/4
81/4
85/8
61/4
81/8
95/8
95/8

lbs
62

load
group
5-6

lbs
100
122
180
191
285
405
99
126
187
305
153
285
330
425
178
349
483
550

load
group
4-7
6-9
6-9
7-10
8-30
9-30
4-7
6-9
7-10
8-30
5-8
6-9
7-10
8-30
5-8
6-9
7-10
8-30

lbs
max. min. max.
651/2 308 414
651/2 410 520
651/2 510 665
651/2 680 920
651/2 785 990
75 340 550
75 525 710
75 660 960
75 765 1120
81 460 680
81 595 875
81 725 1100
81 970 1435
81 1255 1790
81 1500 2135
81 540 808
81 739 1091
81 893 1306
81 1135 1710
81 1554 2249
81 1841 2664

load
group
5-7
6-8
6-9
7-10
8-10
4-7
6-9
7-9
8-10
4-7
5-8
5-8
6-9
7-10
8-30
4-7
5-8
5-8
6-9
7-10
8-30

 Weights for type 46 - for type 48 approx. 23% less.

4.41

B
113/4
13
141/2
15
15

C
221/2
23
241/2
253/8
251/2

H
57/8
77/8
117/8
117/8
117/8

lbs
195
230
252
284
302

SELECTION TABLE
OD 28 - 711.2mm

Twice the specified load is possible


by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 28 (ND 700/28), types 42, 44, 46, 48, 49
Type
42 71 19
Type
44 71 14
44 71 15
44 71 16
44 71 17
44 71 18
44 71 19
44 71 25
44 71 26
44 71 27
44 71 28
44 71 29
44 71 35
44 71 36
44 71 37
44 71 38
44 71 39
44 71 45
44 71 46
44 71 47
44 71 48

Type
4.7111
4. 71 12
4. 71 13
4. 71 14
4. 71 15
4. 71 21
4. 71 22
4. 71 23
4. 71 24
4. 71 31
4. 71 32
4. 71 33
4. 71 34
4. 71 35
4. 71 36
4. 71 41
4. 71 42
4. 71 43
4. 71 44
4. 71 45
4. 71 46

permissible load (lbs x 1000)


210 480 660 840 930 950
3.35 2.45 1.80

210
9.6
21.3
27.8
33.7
39.7
69.0

210
16.6
26.5
40.4
53.0
61.8

permissible load (lbs x 1000)


480 660 840 930 950
8.0 6.7
16.8 13.4
19.7 16.1
27.0 19.7
32.5 25.8
50.5 40.4
5.8 5.3
9.6 8.9
14.6 13.4
21.3 18.0
29.4 27.0
8.9
16.1
23.5
37.0 34.8
50.5 43.8

985 1040 1075 1110F

d2
1.20

985 1040 1075 1110F

d3
1.60
2.00
2.40
2.80
2.80
2.80
1.60
2.00
2.40
2.80
2.80
1.80
2.00
2.40
2.80
2.80
1.80
2.00
2.40
2.80

7.8 5.6
13.9 8.9
19.1 13.4
28.0 18.0
38.2 24.0
9.4 6.9
20.0 14.8
28.5 21.1
53.7 35.0 25.8

permissible load (lbs x 1000)


480 660 840 930 950 985 1040 1075 1110F
12.8 9.4
20.2 15.7
29.8 23.5
39.3 31.9
45.0 35.9
15.7 11.2
24.7 18.0
43.8 38.2 28.0
54.0 43.8 35.0
13.4 10.3 6.0
20.0 15.5 8.9
39.3 31.4 23.5 14.1
50.5 41.5 30.7 18.0
76.4 63.0 45.0 27.0
99.0 82.0 60.6 35.0
11.0 8.3 6.0
16.1 12.1 8.9
25.8 19.3 14.1
32.5 24.5 17.9
48.7 36.6 26.9
63.6 47.8 35.0

permissible load
Type
210 480 660 840
49 71 13 19.1 15.0 11.0
49 71 14 29.2 22.4 16.1
49 71 25
20.6 18.4
49 71 35
33.7
49 71 45

Temperature up to
1200F see page 4.46

5.1
10.5
15.2
19.3

d3
1.60
1.80
2.00
2.00
2.40
1.80
2.00
2.00
2.40
1.60
1.80
2.00
2.00
2.40
2.80
1.60
1.80
2.00
2.00
2.40
2.80

EK
13/4
21/4
21/2
31/4
31/2
23/4
23/4
23/4
31/2
23/4
23/4
4
4
4
51/4
23/4
23/4
4
4
4
51/4

(lbs x 1000)
930 950 985 1040 1075 1110F

14.6
31.9 30.3 22.2 13.0
24.3 18.2

13.0

ER
75/8
91/2
87/8
9
81/2
85/8
91/2
97/8
11
91/4
97/8
111/4
12
131/4
131/2
91/2
111/2
12
121/2
14
141/2

E
B
24 3/4 55/8
24 3/4 63/8
24 3/4 65/8
24 3/4 71/8
24 3/4 83/4
25 1/2 91/4
28 1/2 43/4
28 1/2 51/2
28 1/2 57/8
28 1/2 61/2
28 1/2 73/4
29 1/8 61/2
29 1/8 73/8
29 1/8 81/4
29 1/8 85/8
29 1/8 10
29 1/8 63/4
29 1/8 81/2
29 1/8 10
29 1/8 95/8

L
min.
43 1/2
43 1/2
431/2
431/2
431/2
491/4
491/4
531/4
531/4
511/4
511/4
511/4
551/4
551/4
571/4
51
51
51
55
55
57

E
20
217/8
253/4
253/4
253/4

B
31/2

E
17

max.
671/2
671/2
671/2
671/2
671/2
79
79
79
79
83
83
83
83
83
83
821/2
821/2
821/2
821/2
821/2
821/2

A
153/4
157/8
177/8
18
18

lbs
66

load
group
5-6

lbs
154
196
211
239
330
430
117
144
202
235
320
169
242
350
440
560
213
392
528
576

load
group
4-7
6-9
7-10
8-30
8-30
9-30
5-7
6-9
7-10
8-30
8-30
5-8
6-9
7-10
8-30
9-30
5-8
6-9
7-10
8-30

lbs
min. max.
374 496
490 680
605 870
780 1030
1020 1100
420 615
570 795
760 1055
925 1240
500 730
655 940
905 1325
1095 1535
1365 1910
1700 2360
631 907
802 1169
1096 1601
1283 1824
1689 2403
2081 2925

B
121/2
133/4
151/2
161/4
161/4

C
221/2
23
25
253/8
251/2

H
57/8
77/8
117/8
117/8
117/8

load
group
5-7
6-8
7-9
7-9
8-10
5-8
6-9
7-9
8-10
4-7
5-8
6-9
6-9
7-10
8-30
4-7
5-8
6-9
6-9
7-10
8-30

Heat resistant materials


see page 4.3

 Type 46

 Type 48

172
87/8

 Weights for type 46 - for


type 48 approx. 26% less.

lbs
207
245
270
305
326

4.42

SELECTION TABLE
OD 30 - 762mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 30 (ND 750/30), types 42, 44, 46, 48, 49

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F d2
42 76 19 3.10 2.20 1.70
1.20

Heat resistant materials


see page 4.3

 Type 46

 Type 48

198
97/

 Weights for type 46 - for


type 48 approx. 24% less.

Type
44 76 14
44 76 15
44 76 16
44 76 17
44 76 18
44 76 19
44 76 25
44 76 26
44 76 27
44 76 28
44 76 29
44 76 35
44 76 36
44 76 37
44 76 38
44 76 39
44 76 45
44 76 46
44 76 47
44 76 48
44 76 49
Type
4.7611
4. 76 12
4. 76 13
4. 76 14
4. 76 15
4. 76 21
4. 76 22
4. 76 23
4. 76 24
4. 76 31
4. 76 32
4. 76 33
4. 76 34
4. 76 35
4. 76 36
4. 76 41
4. 76 42
4. 76 43
4. 76 44
4. 76 45
4. 76 46

210
12.1
18.6
25.8
33.7
43.8
69.0

480
9.4
15.0
19.7
25.8
34.8
50.5

permissible load (lbs x 1000)


660 840 930 950 985
7.4
11.9
16.1
19.7
26.9
40.4
9.6 8.9
14.3 13.4
21.3 18.0
27.0 22.4
49.4 41.5 37.0
8.9 8.7
16.1 14.3
23.5 21.3
36.0 30.3
53.0 49.0 40.4

1040 1075 1110F

5.8
8.9
13.4
20.2
26.7
11.2
20.2
28.5
51.7 35.5
75.3 48.3

210
16.6
27.0
41.1
55.0
69.6

480
12.8
20.4
30.3
40.4
51.6

8.5
14.8
20.9
26.0
35.7

permissible load (lbs x 1000)


660 840 930 950 985 1040 1075 1110F d3
9.4
1.60
15.5
1.80
23.5
2.00
31.4
2.00
41.5
2.40
15.7 11.2
1.80
24.7 18.0
2.00
45.0 40.4 29.2
2.00
63.0 53.0 40.4
2.40
15.5 11.4 6.7
1.60
20.2 15.5 8.9
1.80
31.4 22.4 13.4
2.00
50.5 41.5 30.7 18.0
2.00
76.4 63.0 45.0 27.0
2.40
115.0 90.0 65.1 40.4
2.80
12.1 9.2 6.7 1.60
16.1 12.1 8.9 1.80
24.5 18.4 13.4 2.00
32.5 24.5 17.9 2.00
49.2 36.6 26.9 2.40
73.2 55.3 40.4 2.80

6.0
10.5
15.2
19.3
26.7

d3
1.60
2.00
2.40
2.80
2.80
2.80
2.00
2.40
2.80
2.80
2.80
1.80
2.00
2.40
2.80
2.80
1.80
2.00
2.40
2.80
2.80

EK ER
13/4 8 1/2
21/4 8 1/2
21/2 9 5/8
31/4 10 1/4
31/2 10
23/4 9 7/8
23/4 9 7/8
31/4 113/4
31/2 11 3/4
31/4 10 1/4
31/4 10 3/4
4 12 1/4
4 13
41/4 14 1/4
51/2 15 3/4
31/4 10 3/4
31/4 11 1/4
4 13 1/4
4 13 1/2
41/4 14 1/4
51/2 17

L
min.
451/4
451/4
451/4
451/4
451/4
551/4
551/4
591/4
591/4
591/4
591/4
591/4
591/4
591/4
63
59
59
59
59
59
63

E
26 1/2
26 1/2
26 1/2
26 1/2
26 1/2
27 1/4
30
30
30
30
30
30 1/4
30 1/4
30 1/4
30 1/4
301/4
301/4
301/4
301/4
301/4
301/4

B
61/8
63/8
65/8
71/8
83/4
91/4
51/2
57/8
61/2
73/4
85/8
63/4
73/8
81/4
87/8
10
75/8
81/2
10
10
107/8

max.
69 1/2
69 1/2
69 1/2
69 1/2
69 1/2
87
87
87
87
91
91
91
91
91
91
90 1/2
90 1/2
90 1/2
90 1/2
90 1/2
90 1/2

permissible load (lbs x 1000)


Type
210 480 660 840 930 950 985 1040 1075 1110F E
A
49 76 13 21.3 19.1 13.9
21 157/8
49 76 14 33.0 24.7 18.0
227/8 157/8
49 76 25
23.3 21.1 17.1
263/4 173/4
49 76 35
38.4 36.4 34.8 26.9 15.7
263/4 18
49 76 45
28.8 21.6
15.7 263/4 18

4.43

B lbs
31/2 68

E
18

B
13 1/2
14 1/2
15 3/4
16 1/2
16 1/2

load
lbs group
182 4-7
199 6-9
215 7-10
248 8-30
355 8-30
450 9-30
154 6-9
210 7-10
265 8-30
330 8-30
460 9-30
189 5-8
275 6-9
370 7-10
480 8-30
650 9-30
297 5-8
413 6-9
549 7-10
628 8-30
789 9-30

lbs
min. max.
410 530
535 745
790 920
990 1090
1110 1290
485 765
660 960
890 1230
1150 1545
640 905
770 1085
1040 1485
1240 1745
1535 2175
2115 2860
798 1098
948 1344
1268 1772
1484 2081
1956 2733
2641 3583
C
23 1/4
23
25
25 3/8
25 1/2

load
group
5-6

H
5 7/8
77/8
117/8
117/8
117/8

load
group
5-7
6-8
7-9
7-9
8-10
5-8
6-9
7-9
8-10
4-7
5-8
6-9
6-9
7-10
8-30
4-7
5-8
6-9
6-9
7-10
8-30
lbs
236
260
304
316
348

SELECTION TABLE
OD 32 - 812.8mm
Pipe clamps, clamp bases, OD 32 (ND 800/32), types 42, 44, 46, 48, 49
permissible load (lbs x 1000)
Type
210 480 660 840 930 950
42 81 19 3.10 2.20 1.65

Type
44 81 14
44 81 15
44 81 16
44 81 17
44 81 18
44 81 19
44 81 25
44 81 26
44 81 27
44 81 28
44 81 29
44 81 35
44 81 36
44 81 37
44 81 38
44 81 39
44 81 45
44 81 46
44 81 47
44 81 48

Type
4.8111
4. 81 12
4. 81 13
4. 81 14
4. 81 15
4. 81 21
4. 81 22
4. 81 23
4. 81 24
4. 81 31
4. 81 32
4. 81 33
4. 81 34
4. 81 35
4. 81 36
4. 81 41
4. 81 42
4. 81 43
4. 81 44
4. 81 45
4. 81 46

210
12.1
20.2
27.4
34.3
46.0
69.0

210
20.2
30.3
47.6
62.0
74.0

permissible load (lbs x 1000)


480 660 840 930 950
9.4 7.6
15.7 12.8
19.7 16.0
25.8 19.7
37.0 28.0
50.5 40.4
9.6 8.9
14.6 13.4
20.2 18.0
28.0 23.5
49.4 42.6 38.2
15.7
23.5
33.7
36.0
49.4 49.0

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

985 1040 1075 1110F

d2
1.20

E
19

B
31/2

lbs
73

load
group
5-6

985 1040 1075 1110F

d3
1.60
2.00
2.40
2.80
2.80
2.80
2.00
2.40
2.80
2.80
2.80
2.00
2.40
2.80
2.80
2.80
2.00
2.40
2.80
2.80

E
27 1/2
27 1/2
27 1/2
27 1/2
27 1/2
28 1/2
31 1/8
31 1/8
31 1/8
31 1/8
31 1/8
32
32
32
32
32
32
32
32
32

B
61/8
63/8
65/8
71/8
83/4
91/4
51/2
57/8
63/4
73/4
85/8
73/8
81/4
87/8
85/8
10
81/2
10
10
111/4

lbs
196
213
230
270
360
475
165
228
270
345
485
275
390
500
570
685
429
571
661
865

load
group
4-7
6-9
7-10
8-30
8-30
9-30
6-9
7-10
8-30
8-30
9-30
6-9
7-10
8-30
8-30
9-30
6-9
7-10
8-30
9-30

14.0
19.1
28.0
33.7
40.4

8.9
13.4
19.1
22.4
26.5
19.1
28.3
49.7 35.5
74.6 48.7

14.3
20.6
25.8
36.1

permissible load (lbs x 1000)


480 660 840 930 950 985 1040 1075 1110F d3
15.5 12.3
1.80
22.4 18.0
2.00
34.8 27.6
2.40
46.0 36.6
2.40
55.0 43.8
2.80
15.7 11.2
1.80
24.7 18.0
2.00
49.4 40.4 31.4
2.40
69.6 58.4 45.0
2.80
1.80
18.0 13.2 7.6
1.80
22.4 18.0 10.3
2.00
31.4 22.4 13.4
49.4 41.5 30.7 18.0
2.00
76.4 63.0 45.0 27.0
2.40
126.0 90.0 76.5 45.0
2.80
13.4 10.1 7.6 1.80
18.4 13.9 10.3 1.80
24.2 18.2 13.4 2.00
32.8 24.2 17.9 2.00
49.2 36.6 26.9 2.40
82.0 61.1 44.9 2.80

10.1
15.2
19.3
26.7

EK
13/4
21/2
23/4
31/2
4
31/4
31/4
31/2
4
31/2
31/2
4
41/4
43/4
6
31/2
31/2
4
41/4
43/4
6

permissible load (lbs x 1000)


Type 210 480 660 840 930 950 985 1040 1075 1110F
49 81 13 23.6 19.1 14.1
49 81 14 33.7 26.3 19.3
49 81 25
26.5 24.2 19.3
49 81 35
42.2 40.0 38.2 29.5 18.5
49 81 45
33.9 25.4 18.5

ER
81/2
91/2
10
95/8
101/2
97/8
97/8
121/2
121/2
11
113/4
13
133/4
141/2
161/4
111/2
113/4
131/2
133/4
141/2
181/4

E
217/8
237/8
273/4
273/4
273/4

L
min. max.
471/4 711/2
471/4 711/2
471/4 711/2
471/4 711/2
471/4 711/2
591/4 91
591/4 91
63 91
63 91
63 95
63 95
63 95
63 95
63 95
63 95
63 941/2
63 941/2
63 941/2
63 941/2
63 941/2
63 941/2

lbs
min. max.
510 640
700 810
890 1135
1215 1380
1310 1530
540 855
730 1060
1070 1420
1385 1820
790 1070
915 1305
1140 1610
1370 1855
1695 2345
2390 3420
961 1325
1160 1571
1400 1928
1653 2262
2167 2960
2998 4171

load
group
5-8
6-9
7-10
8-10
9-30
5-8
6-9
7-10
8-30
5-8
5-8
6-9
6-9
7-10
8-30
5-8
5-8
6-9
6-9
7-10
8-30

B
141/4
153/4
163/4
163/4
163/4

C
H
23 1/8 5 7/8
23
77/8
25
117/8
3
25 /8 117/8
25 1/2 117/8

lbs
247
277
321
328
370

A
15 7/8
15 7/8
17 3/4
18
18

Heat resistant materials


see page 4.3

 Type 46

 Type 48

198
97/8

 Weights for type 46 - for


type 48 approx. 26% less.

4.44

SELECTION TABLE
OD 36 - 914.4mm

Temperature up to
1200F see page 4.46
Twice the specified load is possible
by use of type 77 (see page 4.55)

Pipe clamps, clamp bases, OD 36 (ND 900/36), types 42, 44, 46, 48, 49
permissible load (lbs x 1000)
210 480 660 840 930 950 985 1040 1075 1110F d2
42 91 19 3.10 2.20 1.70
1.20
Type

Type

Heat resistant materials


see page 4.3

 Type 46

44 91 14
44 91 15
44 91 16
44 91 17
44 91 18
44 91 19
44 91 25
44 91 26
44 91 27
44 91 28
44 91 29
44 91 35
44 91 36
44 91 37
44 91 38
44 91 46
44 91 47
44 91 48
Type

 Type 48

225
11

 Weights for type 46 - for


type 48 approx. 28% less.

4.9111
4. 91 12
4. 91 13
4. 91 14
4. 91 15
4. 91 21
4. 91 22
4. 91 23
4. 91 24
4. 91 25
4. 91 31
4. 91 32
4. 91 33
4. 91 34
4. 91 35
4. 91 36
4. 91 41
4. 91 42
4. 91 43
4. 91 44
4. 91 45
4. 91 46

210
11.4
19.7
34.3
46.0
57.0
69.0

permissible load (lbs x 1000)


480 660 840 930 950 985
8.9 7.4
15.5 12.5
25.8 19.7
38.2 28.0
46.0 37.0
50.5 40.4
14.6 13.4
20.2 18.0
28.0 23.5
31.4 29.2
49.4 42.6 38.2
22.4 20.2
33.7 29.2
43.8 41.5 36.0
54.0 49.4 41.1

1040 1075 1110F

13.4
18.0
23.1
26.7
28.5 21.1
49.9 35.5 25.8
74.6 49.0 36.1

210 480
21.5 16.0
30.3 22.4
48.3 34.8
63.0 46.0
75.2 55.0

permissible load (lbs x 1000)


660 840 930 950 985 1040 1075 1110F d3
12.8
1.80
18.0
2.00
28.0
2.40
37.0
2.40
43.8
2.80
18.0 13.4
1.80
25.8 19.1
2.00
47.1 40.4 31.4
2.40
65.1 56.1 45.0
2.80
81.0 67.4 54.0
2.80
1.80
20.2 15.5 8.9
1.80
31.4 22.4 13.4
2.00
41.5 30.7 18.0
89.8 74.0 52.8 31.4
2.40
130 108 76.4 45.0
2.80
153 124 90.0 54.0
2.80
16.1 12.1 8.9 1.80
24.5 18.4 13.4 1.80
32.8 24.7 17.9 2.00
57.3 43.1 31.4 2.40
81.8 61.1 44.9 2.80
98.4 73.0 53.9 2.80

15.2
19.3
26.7
EK
2
21/2
23/4
31/2
4
31/4
31/2
4
4
41/4
4
41/4
41/4
51/4
51/4
61/4
4
41/4
41/4
51/4
51/4
61/4

permissible load (lbs x 1000)


210 480 660 840 930 950 985 1040 1075 1110F
49 91 13 29.2 22.9 16.8
49 91 14 52.8 36.6 29.6
49 91 25
33.2 29.2 26.9
49 91 35
56.1 53.5 51.0 39.5 24.7
49 91 45
47.2 35.0 24.7
Type

4.45

d3
1.60
2.00
2.40
2.80
2.80
2.80
2.00
2.80
2.80
2.80
2.80
2.40
2.80
2.80
2.80
2.40
2.80
2.80

ER
10
91/2
91/2
101/2
111/2
97/8
103/4
113/4
123/4
131/2
113/4
13
133/4
151/4
18
171/4
113/4
131/2
141/2
171/2
171/2
191/4

E
21

B
4

lbs
88

load
group
5-6

E
30
30
30
30
30
31
33
33
33
33
33
34 1/4
34 1/4
34 1/4
34 1/4
34 1/4
34 1/4
34 1/4

B
6 1/8
6 3/8
77/8
83/4
9
91/4
57/8
63/4
73/4
85/8
85/8
81/4
87/8
85/8
10
10
10
111/4

lbs
213
234
300
395
480
520
250
300
380
505
535
435
545
625
745
636
727
926

load
group
4-7
6-9
7-10
8-30
8-30
9-30
7-9
8-30
8-30
9-30
9-30
7-10
8-30
9-30
9-30
7-10
8-30
9-30

L
min. max.
51 75
51 75
51 75
51 75
51 75
63 95
63 95
63 95
63 95
63 95
67 98 1/2
67 98 1/2
67 98 1/2
67 98 1/2
71 98 1/2
71 98 1/2
67 98 1/2
67 98 1/2
67 98 1/2
67 98 1/2
71 98 1/2
71 98 1/2

E
24
257/8
293/4
293/4
293/4

A
177/8
18
20
20
20

lbs
min. max.
620 755
810 975
1190 1295
1385 1580
1660 1655
675 915
870 1255
1180 1570
1510 1980
1695 2285
985 1315
1280 1725
1565 2100
2175 2850
2840 3795
3210 4185
1215 1633
1537 2088
1885 2560
2701 3672
3510 4640
3944 5313

B
14 1/4
16 1/2
17 3/4
19
19

C
25 1/2
26
28
28
28

H
5 7/8
77/8
117/8
117/8
117/8

load
group
5-8
6-9
7-10
8-10
9-30
5-8
6-9
7-10
8-30
9-30
5-8
5-8
6-9
7-10
8-30
9-30
5-8
5-8
6-9
7-10
8-30
9-30

lbs
294
355
375
430
463

SELECTION TABLE
OD 1.33 - 3.50, TEMPERATURE 1130-1200F
Pipe clamps, OD 1.33 (ND 25/1), type 43
Type
43 03 59

permissible load (lbs x 1000)


1148
1184
1130
1166
0.63
0.47
0.72
0.52

1200F
0.40

d1
0.48

E
91/4

B
2

lbs
3.0

load
group
C-2

d1
0.48

E
91/2

B
2

lbs
3.2

load
group
C-2

d1
0.48

E
91/2

B
2

lbs
3.2

load
group
C-2

Pipe clamps, OD 1.67 (ND 32/11/4), type 43


Type
43 04 59

permissible load (lbs x 1000)


1130
1148
1166
1184
0.72
0.63
0.52
0.47

1200F
0.40

Pipe clamps, OD 1.90 (ND 40/11/2), type 43


Type
43 05 59

permissible load (lbs x 1000)


1130
1148
1166
1184
0.72
0.63
0.52
0.47

1200F
0.40

Type 43

Pipe clamps, OD 2.37 (ND 50/2), type 43


Type
43 06 59

permissible load (lbs x 1000)


1130
1148
1166
1184
0.92
0.79
0.65
0.58

1200F
0.52

d1
0.48

E
97/8

B
21/8

lbs
5.3

load
group
C-4

d1
0.48

E
10

lbs
5.5

load
group
C-4

Pipe clamps, OD 2.87 (ND 65/21/2), types 43, 48


Type
43 07 59
Type
4807 51
48 07 52
48 07 53

permissible load (lbs x 1000)


1148
1184
1130
1166
0.79
0.58
0.92
0.65
permissible load (lbs x 1000)
1130 1148 1166 1184 1200F
0.9
1.1
1.5 1.3
0.9
1.3
1.8
2.2 2.0
1.3
2.4
2.9
3.8 3.3
2.2

1200F
0.52
d3
0.81
0.81
1.00

ER
2 3/4
2 3/4
3 7/8

dN
1 3/8
1 3/8
1 3/8

23/8

L
min. max.
14 29 1/2
14 29 1/2
14 29 1/2

lbs
min. max.
13 29
15 33
20 46

load
group
C-4
C-4
3-5

Type 48

Pipe clamps, OD 3.00 (ND 65/21/2), types 43, 48


Type
43 08 59

permissible load (lbs x 1000)


1148
1184
1130
1166
0.79
0.58
0.92
0.65

1200F
0.52

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
4808 51
0.9
1.3
1.1
1.5
0.9
0.81
48 08 52 2.2
1.3
2.0
1.8
1.3
0.81
48 08 53 3.8
2.4
3.3
2.9
2.2
1.00
Type

dN
1 3/8
1 3/8
1 3/8

d1
0.48
ER
2 3/4
2 3/4
3 7/8

E
10
L
min. max.
14 29 1/2
14 29 1/2
14 29 1/2

lbs
5.6

load
group
C-4

lbs
min. max.
13 29
15 33
20 46

load
group
C-4
C-4
3-5

B
23/8

Pipe clamps, OD 3.50 (ND 80/3), types 43, 48


Type
43 09 59
Type
48 09 51
48 09 52
48 09 53

permissible load (lbs x 1000)


1148
1184
1130
1166
0.79
0.58
0.92
0.65
permissible load (lbs x 1000)
1130 1148 1166 1184 1200F
0.9
1.3
1.1
1.5
0.9
1.3
2.0
1.8
2.2
1.3
2.4
3.3
2.9
3.8
2.2

1200F
0.52
d3
dN
0.81 1 3/8
0.81 1 3/8
1.00 1 3/8

d1
0.48
ER
3
3 3/8
3 7/8

E
101/4
L
min. max.
14 33 1/2
14 33 1/2
14 33 1/2

lbs
5.9

load
group
C-4

lbs
min. max.
13 35
15 42
20 57

load
group
C-4
C-4
3-5

B
23/4

4.46

SELECTION TABLE
OD 4.25 - 6.25, TEMPERATURE 1130 - 1200F
Pipe clamps, OD 4.25 (ND 100/4), types 43, 48
Type
43 10 59
Type
48 10 51
48 10 52
48 10 53

permissible load (lbs x 1000)


1148
1184
1130
1166
1.73
1.28
2.00
1.42

1200F
1.12

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
2.0
1.8 1.3
2.2
1.3
0.81
2.7
2.2 2.0
2.9
1.8
1.00
5.1
4.7 3.8
6.0
3.3
1.34

dN
2
2
2

d1
0.63

E
101/2
L
min.
14
14
14

ER
3 3/8
3 3/4
5 1/2

B
23/4

lbs
11.2

lbs
min. max.
18 53
22 62
31 93

max.
37 1/2
37 1/2
37 1/2

load
group
1-4
load
group
C-4
3-5
3-6

Pipe clamps, OD 4.50 (ND 100/4), types 43, 48


Type
43 11 59

Type
Type 43

48 11 51
48 11 52
48 11 53

1130
2.00

permissible load (lbs x 1000)


1148
1184
1166
1200F
1.73
1.28
1.42
1.12

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
1.3
2.0 1.8
2.2
1.3
0.81
2.0
2.7 2.2
2.9
1.8
1.00
3.8
5.1 4.7
6.0
3.3
1.34

d1
0.63

E
103/4
L

dN
2
2
2

ER
3 3/8
3 3/4
5 1/2

max.
37 1/2
37 1/2
37 1/2

min.
14
14
14

B
23/4

lbs
11.4

lbs
min. max.
53
18
62
22
93
31

load
group
1-4

load
group
C-4
3-5
3-6

Pipe clamps, OD 5.25 (ND 125/5), types 43, 48


Type
43 13 59

1130
2.25

permissible load (lbs x 1000)


1200F
1148
1184
1166
1.26
1.96
1.46
1.60

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
48 13 51
2.7 2.2 2.0 1.8
1.5
0.81
48 13 52
3.8 3.3 2.9 2.4
2.2
1.00
48 13 53
6.5 5.8 4.9 4.2
3.8
1.34
Type

Type 48

d1
0.63

E
111/2

B
31/8

L
dN
2
2
2

ER
3 3/4
4 3/8
5 7/8

lbs
max.
39 1/2
39 1/2
39 1/2

min.
16
16
16

lbs
11.7

max.
60
75
108

min.
22
26
37

load
group
1-4

load
group
C-4
3-5
4-6

Pipe clamps, OD 5.50 (ND 125/5), types 43, 48


Type
43 14 59

1130
2.25

permissible load (lbs x 1000)


1200F
1148
1184
1166
1.26
1.96
1.46
1.60

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
48 14 51
2.7 2.2 2.0 1.8
1.5
0.81
48 14 52
3.8 3.3 2.9 2.4
2.2
1.00
48 14 53
6.5 5.8 4.9 4.2
3.8
1.34
Type

d1
0.63

E
111/2

B
31/8

L
dN
2
2
2

ER
3 3/4
4 3/8
5 7/8

lbs
18.1
lbs

max.
39 1/2
39 1/2
39 1/2

min.
16
16
16

max.
62
77
108

min.
22
29
40

load
group
1-4

load
group
C-4
3-5
4-6

Pipe clamps, OD 6.25 (ND 150/6), types 43, 48


Type
43 16 59

1130
2.25

permissible load (lbs x 1000)


1200F
1148
1166
1184
1.26
1.96
1.60
1.46

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
4816 51
2.7 2.2 2.0 1.8
1.5 0.81
48 16 52
4.2 3.6 3.3 2.7
2.4 1.00
48 16 53
8.1 6.7 6.0 5.1
4.5 1.34
Type

4.47

d1
0.63

E
121/2

B
31/8

L
dN
21/2
21/2
21/2

ER
3 7/8
4 7/8
5 7/8

min.
18
18
18

lbs
19.5
lbs

max.
41 1/2
41 1/2
41 1/2

min.
26
35
51

max.
68
90
132

load
group
1-4

load
group
C-4
3-5
4-6

SELECTION TABLE
OD 6.625 - 9.625, TEMPERATURE 1130 - 1200F
Pipe clamps, OD 6.625 (ND 150/6), types 43, 48
Type
43 17 59

permissible load (lbs x 1000)


1148
1184
1130
1166
1.96
1.46
2.25
1.60

1200F
1.26

d1
0.63

E
121/2

lbs
20

load
group
1-4

max.
68
93
132

load
group
C-4
3-5
4-6

lbs
35

load
group
3-6

max.
73
101
123
181

load
group
C-4
3-5
3-5
4-7

lbs
46
79
123

load
group
C-4
4-6
5-8

max.
112
157
190
271

load
group
C-4
3-5
4-7
5-8

B
31/8

4
Type 43

Type
48 17 51
48 17 52
48 17 53

1130
2.7
4.2
8.1

permissible load (lbs x 1000)


1148 1166 1184 1200F
2.2 2.0 1.8 1.5
3.6 3.3 2.7 2.4
6.7 6.0 5.1 4.5

L
dN
2 1/2
2 1/2
2 1/2

d3
0.81
1.00
1.34

lbs
max.
411/2
411/2
411/2

ER min.
3 7/8 18
4 7/8 18
5 7/8 18

min.
26
35
51

Pipe clamps, OD 7.625 (ND 175/7), types 43, 48


Type
43 19 59

permissible load (lbs x 1000)


1148
1184
1130
1166
3.15
2.47
3.82
2.70

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F
48 19 51
2.2 2.0 1.8 1.3
1.3
48 19 52
3.8 3.3 2.9 2.4
2.2
48 19 53
5.6 4.7 4.2 3.6
3.1
48 19 54
9.9 8.5 7.6 6.3
5.6
Type

1200F
2.02

d1
0.79

B
37/8

E
14
L

d3
0.81
1.00
1.00
1.60

dN
2
2
2
2

1/
2
1/
2
1/
2
1/
2

min.
21 1/2
21 1/2
21 1/2
21 1/2

ER
4 3/8
4 7/8
5 7/8
6 1/4

lbs
max.
45 1/2
45 1/2
45 1/2
45 1/2

min.
35
46
55
84

Type 44

Pipe clamps, OD 8.625 (ND 200/8), types 44, 48


Type
44 22 51
44 22 52
44 22 53

1130
1.8
4.2
6.7

permissible load (lbs x 1000)


1148 1166 1184 1200F
1.1
1.1
1.5
1.3
2.4
2.7
3.8
3.1
3.8
4.2
5.8
4.9

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F
48 22 51
2.2 2.0 1.8 1.5
1.3
48 22 52
5.1 4.5 3.8 3.3
2.9
48 22 53
6.9 6.0 5.4 4.5
4.0
48 22 54 12.1 10.3 9.2 7.8
6.9
Type

d3
0.81
1.34
1.80

E
16 7/8
18 1/8
19 1/8

max
B
4 1/2
4 1/8
6 1/2

max
ISO
11
11
11

L
d3
0.81
1.00
1.60
1.80

dN
3 1/8
3 1/8
3 1/8
3 1/8

min.
21 1/2
21 1/2
21 1/2
21 1/2

ER
5 1/8
5 7/8
6 3/4
7 7/8

lbs
max.
53
53
53
53

min.
40
57
71
106

Type 48

Pipe clamps, OD 9.625 (ND 225/9), types 44, 48


Type
44 24 51
44 24 52
44 24 53

1130
1.8
4.2
6.7

permissible load (lbs x 1000)


1148 1166 1184 1200F
1.1
1.5
1.3
1.1
2.7
3.8
3.1
2.4
4.2
5.8
4.9
3.8

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F
48 24 51
2.7 2.4 2.0 1.8 1.5
48 24 52
5.6 4.7 4.2 3.6 3.1
48 24 53
8.1 6.9 6.3 5.4 4.5
48 24 54 13.4 11.9 10.1 9.0 7.6
Type

d3
0.81
1.34
1.80

E
17 3/8
18 3/4
19 5/8

max
B
4 3/4
4 1/8
6 3/4

max
ISO
11
11
11

L
d3
1.00
1.00
1.60
1.80

dN
3 1/8
3 1/8
3 1/8
3 1/8

ER
4 3/8
5 7/8
6 1/4
7 1/8

min.
21 1/2
21 1/2
21 1/2
21 1/2

max.
53
53
53
53

min.
44
62
82
110

lbs
50
82
131
lbs
max.
123
165
209
287

load
group
C-4
4-6
5-8
load
group
3-5
3-5
4-7
5-8

4.48

SELECTION TABLE
OD 10.50 - 12.75, TEMPERATURE 1130 - 1200F
Pipe clamps, OD 10.50 ND 250/10), types 44, 48
Type
44 26 51
44 26 52
44 26 53

1130
1.8
4.2
6.9

permissible load (lbs x 1000)


1148 1166 1184 1200F
1.1
1.1
1.3
1.5
2.7
2.4
3.1
3.8
4.5
4.0
5.1
6.0

permissible load
1130 1148 1166 1184
48 26 51
3.1 2.7 2.4 2.0
48 26 52
5.8 4.9 4.5 3.8
48 26 53
8.3 7.2 6.5 5.4
48 26 54 14.6 12.5 11.2 9.4
Type

(lbs x 1000)
1200F d3
1.8
1.00
3.3
1.00
4.7
1.60
8.1
1.80

d3
0.81
1.34
1.80

dN
3 5/8
3 5/8
3 5/8
3 5/8

E
17 7/8
19 1/8
19 7/8

ER
4 3/4
5 7/8
6 1/4
7 5/8

max
B
4 7/8
4 3/8
6 1/8

L
min. max.
23 1/2
55
23 1/2
55
23 1/2
55
23 1/2
55

max
ISO
11
11
11

lbs
53
88
140

lbs
min.
53
71
95
130

load
group
C-4
4-6
5-8

max.
141
185
231
322

load
group
3-5
3-5
4-7
5-8

lbs
54
88
141

load
group
C-4
4-6
5-8

max.
141
185
231
324

load
group
3-5
3-5
4-7
5-8

lbs
86
139
191

load
group
3-5
4-6
5-8

max.
185
254
306
355
440

load
group
3-5
4-7
5-8
5-8
6-9

Type 44

Pipe clamps, OD 10.75 (ND 250/10), types 44, 48


Type
44 27 51
44 27 52
44 27 53

Type
Type 48

48 27 51
48 27 52
48 27 53
48 27 54

1130
1.8
4.2
6.9

permissible load (lbs x 1000)


1148 1166 1184 1200F
1.1
1.5
1.1
1.3
2.7
3.8
2.4
3.1
4.5
6.0
4.0
5.1

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
3.1 2.7 2.4 2.0 1.8
1.00
5.8 4.9 4.5 3.8 3.3
1.00
8.3 7.2 6.5 5.4 4.7
1.60
14.6 12.5 11.2 9.4 8.1
1.80

d3
0.81
1.34
1.80

E
17 7/8
19 1/8
19 7/8

max
B
4 7/8
4 3/8
7 1/8

max
ISO
11
11
11

L
dN
3 5/8
3 5/8
3 5/8
3 5/8

ER
4 3/4
5 7/8
6 1/4
7 5/8

min.
23 1/2
23 1/2
23 1/2
23 1/2

lbs
max.
55
55
55
55

min.
53
73
95
132

Pipe clamps, OD 12.75 (ND 300/12), types 44, 48


Type
44 32 51
44 32 52
44 32 53

Type
48 32 51
48 32 52
48 32 53
48 32 54
48 32 55

4.49

1130
3.8
6.7
11.4

1130
4.7
8.7
11.9
15.2
20.2

permissible load (lbs x 1000)


1148 1166 1184 1200F
2.4
3.3
2.2
2.9
4.2
5.8
3.8
4.9
7.4
9.9
6.5
8.5

permissible load (lbs x 1000)


1148 1166 1184 1200F d3
4.0 3.6 3.1
2.7 1.00
7.4 6.7 5.6
4.9 1.60
10.1 9.0 7.6
6.7 1.80
13.0 11.7 9.9
8.7 1.80
17.3 15.5 13.0 11.4 2.00

d3
1.00
1.34
1.80

E
19 5/8
20 1/8
20 7/8

max
B
3 7/8
6 7/8
5 3/4

max
ISO
11 3/8
11 3/8
11 3/8

L
dN
4 5/8
4 5/8
4 5/8
4 5/8
4 5/8

ER
5 7/8
7 1/8
7 1/8
8 1/4
9 7/8

min.
27 1/2
27 1/2
27 1/2
27 1/2
31 1/2

lbs
max.
55
55
55
55
55

min.
82
121
143
163
218

SELECTION TABLE
OD 14 - 16, TEMPERATURE 1130 - 1200F
Pipe clamps, OD 14 ND 350/14), types 44, 48
Type
44 36 51
44 36 52
44 36 53

Type
48 36 51
48 36 52
48 36 53
48 36 54
48 36 55

1130
3.8
6.7
11.4

permissible load (lbs x 1000)


1148 1166 1184 1200F
2.4
2.9
2.2
3.3
4.2
4.9
3.8
5.8
7.4
8.5
6.5
9.9

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F
4.0 3.3 2.9 2.4
2.2
5.6 4.7 4.2 3.6
3.1
9.4 8.1 7.2 6.0
5.4
15.9 13.9 12.1 10.5
9.0
23.6 20.4 18.2 15.2 13.2

d3
1.00
1.34
1.80

max
B
4 1/8
7 1/8
5 3/4

E
20 1/2
20 5/8
21 1/2

max
ISO
11 3/8
11 3/8
11 3/8

L
d3
1.00
1.34
1.60
1.80
2.00

dN
4 5/8
4 5/8
4 5/8
4 5/8
4 5/8

min.
27 1/2
27 1/2
31 1/2
31 1/2
31 1/2

ER
5 1/2
6 1/4
7 1/8
8 5/8
9 1/2

lbs
94
148
200

lbs
max.
59
59
59
59
59

max.
192
225
293
403
518

min.
79
108
146
196
259

load
group
3-5
4-6
5-8

load
group
3-5
4-6
4-7
5-8
6-9
Type 44

Pipe clamps, OD 14.50 (ND 350/14), types 44, 48


Type
44 37 51
44 37 52
44 37 53

Type
48 37 51
48 37 52
48 37 53
48 37 54
48 37 55

1130
3.8
6.9
11.4

permissible load (lbs x 1000)


1148 1166 1184 1200F
2.4
3.3
2.2
2.9
4.5
6.0
4.0
5.1
7.4
9.9
6.5
8.5

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F
2.2
4.0 3.3 2.9 2.4
3.1
5.6 4.7 4.2 3.6
5.4
9.4 8.1 7.2 6.0
9.0
15.9 13.9 12.1 10.5
23.6 20.4 18.2 15.2 13.2

d3
1.00
1.34
1.80

E
20 7/8
21 1/8
21 5/8

max
B
4 3/8
7 1/2
5 7/8

max
ISO
11 3/8
11 3/8
11 3/8

L
d3
1.00
1.34
1.60
1.80
2.00

dN
4 5/8
4 5/8
4 5/8
4 5/8
4 5/8

ER
5 1/2
6 1/4
7 1/8
8 5/8
9 1/2

min.
29 1/2
29 1/2
29 1/2
29 1/2
33 1/2

lbs
99
159
207

lbs
max.
59
59
59
59
59

min.
84
115
139
190
265

load
group
3-5
4-6
5-8

max.
194
227
293
405
520

load
group
3-5
4-6
4-7
5-8
6-9

lbs
106
194
295

load
group
3-5
5-8
6-9

max.
240
311
379
472
668

load
group
3-5
4-7
5-8
5-8
6-9

Type 48

Pipe clamps, OD 16 (ND 400/16), types 44, 48


Type
44 41 51
44 41 52
44 41 53

Type
48 41 51
48 41 52
48 41 53
48 41 54
48 41 55

1130
3.8
9.0
15.0

permissible load (lbs x 1000)


1148 1166 1184 1200F
2.2
2.9
2.4
3.3
5.1
6.7
5.8
7.8
8.5
11.2
9.9
13.0

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F
4.7 4.0 3.6 3.1
2.7
8.1 7.2 6.0 5.4
4.5
11.0 9.4 8.3 7.2
6.3
16.1 14.1 12.3 10.5
9.0
27.8 24.5 21.1 18.4 15.5

d3
1.00
1.60
1.80
1.80
2.00

d3
1.00
1.80
2.00

dN
5 5/8
5 5/8
5 5/8
5 5/8
5 5/8

E
22
22 7/8
22 7/8

ER
6 1/4
7 1/8
7 7/8
9 1/2
9

max
B
4 3/8
5 3/8
7 7/8

L
min.
31 1/2
31 1/2
31 1/2
31 1/2
35 3/8

max
ISO
11 3/4
11 3/4
11 3/4

lbs
max.
63
63
63
63
63

min.
124
154
187
225
348

4.50

SELECTION TABLE
OD 16.50 - 20, TEMPERATURE 1130 - 1200F
Pipe clamps, OD 16.50 (ND 400/16), types 44, 48
Type
44 42 51
44 42 52
44 42 53

Type
48 42 51
48 42 52
48 42 53
48 42 54
48 42 55

1130
3.8
9.4
15.5

permissible load (lbs x 1000)


1148 1166 1184 1200F
2.4
2.9
2.2
3.3
6.0
6.9
5.4
8.3
10.1
11.4
8.7
13.4

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
3.1
3.6
4.0
4.7
2.7
1.00
5.4
6.0
7.2
8.1
4.5
1.60
7.2
8.3
9.4
11.0
6.3
1.80
16.1 14.1 12.3 10.5
9.0
1.80
27.8 24.5 21.1 18.4 15.5
2.00

d3
1.00
1.80
2.00

E
22 1/4
22 3/4
22 3/4

max
B
4 1/2
5 3/8
8 1/4

L
dN
5 5/8
5 5/8
5 5/8
5 5/8
5 5/8

ER
6 1/4
7 1/8
7 7/8
9 1/2
9

min.
31 1/2
31 1/2
31 1/2
35 1/2
35 1/2

max.
63
63
63
63
63

max
ISO
11 3/4
11 3/4
11 3/4

lbs
111
203
309

load
group
3-5
5-8
6-9

max.
240
313
381
472
672

load
group
3-5
4-7
5-8
5-8
6-9

lbs
121
179
308
448

load
group
3-5
5-8
6-9
6-9

max.
344
384
523
805
866

load
group
4-7
5-8
5-8
6-9
7-10

lbs
130
209
370
498

load
group
3-5
5-8
6-9
7-10

max.
392
434
600
908
1034

load
group
4-7
5-8
5-8
6-9
7-10

lbs
min.
125
154
190
245
353

Type 44

Pipe clamps, OD 18 (ND 450/18), types 44, 48


Type
44 46 51
44 46 52
44 46 53
44 46 54

Type
Type 48

48 46 51
48 46 52
48 46 53
48 46 54
48 46 55

1130
3.8
6.9
13.9
22.4

permissible load (lbs x 1000)


1148 1166 1184 1200F
2.2
2.4
2.9
3.3
4.0
4.5
5.1
6.0
7.8
9.0
10.3
12.1
12.5
14.6
16.4
19.3

permissible load
1130 1148 1166 1184
5.1
6.0
6.9
8.1
5.8
6.9
7.8
9.2
15.7 13.7 11.9 10.3
32.1 28.3 24.5 21.3
35.9 31.4 27.6 23.8

(lbs x 1000)
1200F d3
4.5
1.60
5.1
1.80
9.0
1.80
17.9
2.00
20.2
2.40

d3
1.00
1.80
2.00
2.00

E
23 1/4
23 5/8
23 7/8
24 3/8

max
B
4 3/4
5 3/8
7 5/8
12 3/8

max
ISO
11 3/4
11 3/4
11 3/4
11 3/4

L
ER
dN
5 5/8 6 3/4
5 5/8 7 1/2
5 5/8 9
5 5/8 10
5 5/8 10 7/8

min.
35 1/2
35 1/2
35 1/2
39 1/2
39 1/2

lbs
max.
67
67
67
67
67

min.
181
203
262
439
474

Pipe clamps, OD 20 (ND 500/20), types 44, 48


Type
44 51 51
44 51 52
44 51 53
44 51 54

Type
48 51 51
48 51 52
48 51 53
48 51 54
48 51 55

4.51

1130
3.8
7.8
15.7
23.8

permissible load (lbs x 1000)


1148 1166 1184 1200F
2.4
2.9
3.3
2.2
5.1
5.8
6.7
4.5
10.3
11.7
13.7
9.0
15.5
17.7
20.6
13.4

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
4.5
5.1
6.0
6.9
8.1
1.60
5.1
6.0
6.9
8.1
9.22
1.80
9.0
15.9 13.7 12.1 10.3
1.80
32.1 27.4 24.5 20.6 17.9
2.00
39.8 35.0 30.3 26.5 22.4
2.40

d3
1.00
1.80
2.00
2.40

E
24 1/4
24 3/4
25
25 5/8

max
B
4 3/4
5 3/8
9
8 1/4

max
ISO
11 3/4
11 3/4
11 3/4
11 3/4

L
ER
dN
6 3/4 7 1/4
6 3/4 7 7/8
6 3/4 9 1/4
6 3/4 10 7/8
6 3/4 12 1/4

min.
39 1/2
39 1/2
39 1/2
41 1/2
41 1/2

lbs
max.
71
71
71
71
71

min.
216
243
309
503
567

SELECTION TABLE
OD 22 - 26, TEMPERATURE 1130 - 1200F
Pipe clamps, OD 22 (ND 550/22), types 44, 48
Type
44 56 51
44 56 52
44 56 53
44 56 54
Type
48 56 51
48 56 52
48 56 53
48 56 54
48 56 55

1130
7.8
15.7
23.8
31.7

permissible load (lbs x 1000)


1148 1166 1184 1200F
5.1
5.8
6.7
4.5
10.3
11.7
13.7
9.0
15.5
17.7
20.6
13.4
20.9
23.6
27.6
17.9

permissible load (lbs


1130 1148 1166 1184
5.8
6.7
7.6
8.7
8.1
9.2
12.1 10.5
15.9 14.1 12.1 10.5
31.4 27.2 24.0 20.4
48.3 41.8 36.8 31.4

x 1000)
1200F
4.9
6.7
9.0
17.9
26.9

d3
1.80
2.00
2.40
2.40

E
25
26
26
27

3/
4
1/
8
5/
8
1/
8

max
B
5 3/8
9 1/2
8 1/2
11 3/8
L

d3
1.60
1.80
1.80
2.00
2.40

ER
dN
6 3/4 7 7/8
6 3/4 9 1/4
6 3/4 9 1/2
6 3/4 11
6 3/4 14

min.
43 1/2
43 1/2
43 1/2
43 1/2
47

max.
75
75
75
75
75

max
ISO
11 3/4
11 3/4
11 3/4
11 3/4

lbs
229
406
534
672

lbs
min. max.
448
254
551
311
653
350
979
542
743 1275

load
group
5-8
6-9
7-10
7-10
load
group
4-7
5-8
5-8
6-9
7-10

Type 44

Pipe clamps, OD 24 (ND 600/24), types 44, 48


Type
44 61 51
44 61 52
44 61 53
44 61 54

Type
48 61 51
48 61 52
48 61 53
48 61 54
48 61 55
48 61 56

1130
7.8
15.7
23.8
35.7

permissible load (lbs x 1000)


1148 1166 1184 1200F
5.1
5.8
6.7
4.5
10.3
11.7
13.7
9.0
15.5
17.7
20.6
13.4
23.3
26.5
31.2
20.2

permissible load (lbs


1130 1148 1166 1184
5.8
7.6 6.7
8.7
16.4 13.9 12.5 10.5
20.9 18.2 15.9 13.7
31.4 27.6 24.0 20.9
47.8 41.1 36.2 31.0
59.3 52.3 45.4 39.5

x 1000)
1200F
4.9
9.0
11.9
17.5
26.9
33.7

d3
1.80
2.00
2.40
2.80

27
27
28
29

dN
7 7/8
7 7/8
7 7/8
7 7/8
7 7/8
7 7/8

ER
8 5/8
8 7/8
11
11 5/8
14
13 3/4

E
3/
8
3/
4
1/
8
1/
8

max
B
5 3/8
10
8 7/8
9

L
d3
1.60
1.80
1.80
2.00
2.40
2.80

max.
79
79
79
79
79
79

min.
47
47
47
51
51
51

max
ISO
12 1/4
12 1/4
12 1/4
12 1/4

lbs
259
453
586
771

lbs
min. max.
510
300
736
425
835
483
660 1082
842 1391
996 1620

load
group
5-8
6-9
7-10
8-30

load
group
4-7
5-8
5-8
6-9
7-10
8-30

Type 48

Pipe clamps, OD 26 (ND 650/26), types 44, 48


Type
44 66 51
44 66 52
44 66 53
44 66 54
Type
48 66 51
48 66 52
48 66 53
48 66 54
48 66 55
48 66 56

1130
7.8
15.7
23.8
35.7

permissible load (lbs x 1000)


1148 1166 1184 1200F
5.1
5.8
6.7
4.5
10.3
11.7
13.7
9.0
15.5
17.7
20.6
13.4
23.3
26.5
31.2
20.2

permissible load (lbs


1130 1148 1166 1184
6.5
7.6
8.7
10.1
16.1 13.9 12.3 10.5
22.2 19.1 16.8 14.3
32.1 28.3 24.5 21.3
48.7 42.0 37.3 31.7
60.0 52.8 45.8 39.8

x 1000)
1200F
5.6
9.0
12.3
17.9
26.9
33.7

d3
1.80
2.00
2.40
2.80

28
28
29
30

dN
8 7/8
8 7/8
8 7/8
8 7/8
8 7/8
8 7/8

ER
9
9
11
12 1/4
13
13 3/4

E
3/
8
3/
4
3/
8
3/
8

max
B
5 3/8
10 1/4
8
9 1/4
L

d3
1.60
1.80
1.80
2.00
2.40
2.80

min.
49
49
49
49
53
53

max.
81
81
81
81
81
81

max
ISO
12 1/4
12 1/4
12 1/4
12 1/4

lbs
272
485
629
825

lbs
min. max.
657
355
798
478
924
547
703 1177
925 1497
1087 1742

load
group
5-8
6-9
7-10
8-30
load
group
4-7
5-8
5-8
6-9
7-10
8-30

4.52

SELECTION TABLE
OD 28 - 32, TEMPERATURE 1130 - 1200F
Pipe clamps, OD 28 (ND 700/28), types 44, 48
Type
44 71 51
44 71 52
44 71 53
44 71 54
44 71 55
Type
48 71 51
48 71 52
48 71 53
48 71 54
48 71 55
48 71 56

1130
9.9
15.7
23.8
31.7
41.8

permissible load (lbs x 1000)


1148 1166 1184 1200F
8.5
5.6
6.5
7.2
13.7
9.0
10.3
11.7
20.6
13.4
15.5
17.7
27.6
17.9
20.9
23.6
36.4
23.6
27.2
31.0

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F
d3
6.0
7.2
8.3
9.6
11.0
1.60
9.0
16.1 13.7 12.1 10.3
1.80
24.9 21.3 19.1 16.1 14.1
2.00
31.4 26.9 23.8 20.4 17.9
2.00
48.7 42.4 37.3 31.9 26.9
2.40
62.7 55.3 47.8 41.5 35.0
2.80

d3
1.80
2.00
2.40
2.40
2.80

E
29
29
30
30
31

1/
8
7/
4
3/
8
7/
8
1/
4

max
B
6 1/2
10 5/8
9 1/2
8 1/2
11 1/4

max
ISO
12 1/4
12 1/4
12 1/4
12 1/4
12 1/4

L
dN
8 7/8
8 7/8
8 7/8
8 7/8
8 7/8
8 7/8

ER min.
9
51
9
51
11
51
12 1/4 55
13 1/4 55
14
57

max. min.
82 1/2 388
82 1/2 505
82 1/2 659
82 1/2 772
82 1/2 979
82 1/2 1200

lbs
341
525
680
760
1035

load
group
5-8
6-9
7-10
7-10
8-30

lbs
max.
701
829
1079
1221
1565
1860

load
group
4-7
5-8
6-9
6-9
7-10
8-30

lbs
374
569
724
981
1290

load
group
5-8
6-9
7-10
8-30
9-30

lbs
max.
849
970
1235
1442
1795
2355

load
group
4-7
5-8
6-9
6-9
7-10
8-30

lbs
623
797
1012
1132
1375

load
group
6-9
7-10
8-30
8-30
9-30

Type 44

Pipe clamps, OD 30 (ND 750/30), types 44, 48


Type
44 76 51
44 76 52
44 76 53
44 76 54
44 76 55
Type

Type 48

48 76 51
48 76 52
48 76 53
48 76 54
48 76 55
48 76 56

permissible load (lbs x 1000)


1148 1166 1184 1200F
6.5
7.2
8.5
5.6
10.3
11.7
13.7
9.0
15.5
17.7
20.6
13.4
23.3
26.5
31.2
20.2
31.0
35.0
41.3
26.7

d3
1.80
2.00
2.40
2.80
2.80

30
31
31
32
32

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F d3
6.7 1.60
7.8
9.2
12.1 10.3
9.0 1.80
16.1 14.1 12.3 10.5
23.8 20.4 18.2 15.5 13.4 2.00
31.9 27.4 24.2 20.6 17.9 2.00
48.3 42.4 36.8 32.1 26.9 2.40
71.9 63.6 55.0 47.8 40.4 2.80

dN
9 7/8
9 7/8
9 7/8
9 7/8
9 7/8
9 7/8

ER
10 1/4
10 1/4
12 1/4
13 3/8
13
16 1/8

1130
9.9
15.7
23.8
35.7
47.4

E
3/
8
1/
8
1/
2
1/
8
1/
4

max
B
6 7/8
11
9 5/8
9 7/8
12 1/4

max
ISO
12 1/4
12 1/4
12 1/4
12 1/4
12 1/4

L
max.
90 1/2
90 1/2
90 1/2
90 1/2
90 1/2
90 1/2

min.
59
59
59
59
59
63

min.
553
624
794
906
1120
1537

Pipe clamps, OD 32 (ND 800/32), types 44, 48


Type
44 81 51
44 81 52
44 81 53
44 81 54
44 81 55
Type
48 81 51
48 81 52
48 81 53
48 81 54
48 81 55
48 81 56

4.53

1130
15.7
23.8
33.7
39.8
47.4

permissible load (lbs x 1000)


1148 1166 1184 1200F
11.7
10.3
13.7
9.0
17.7
15.5
20.6
13.4
24.9
22.0
29.4
19.1
29.4
26.0
34.6
22.4
35.0
31.0
41.3
26.7

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F
d3
7.6
9.0
13.7 11.9 10.5
1.80
18.4 16.1 14.1 12.1 10.3
1.80
24.0 20.6 18.4 15.5 13.4
2.00
32.1 27.6 24.5 20.9 17.9
2.00
49.0 42.2 37.3 31.9 26.9
2.40
81.1 70.3 62.0 53.0 44.9
2.80

d3
2.00
2.40
2.80
2.80
2.80

32
33
33
33
33

dN
9 7/8
9 7/8
9 7/8
9 7/8
9 7/8
9 7/8

ER
11
11 3/4
13
13 3/4
13 3/4
17 3/4

E
1/

1/

1/

5/

5/

max
B
11 5/8
10 1/4
9 5/8
11 1/4
13 3/8

max
ISO
12 5/8
12 5/8
12 5/8
12 5/8
12 5/8

L
min.
63
63
63
63
63
63

lbs
max. min.
94 1/2
648
94 1/2
719
94 1/2
873
94 1/2
996
94 1/2 1237
94 1/2 1726

max.
980
1107
1330
1552
1938
2715

load
group
5-8
5-8
6-9
6-9
7-10
8-30

SELECTION TABLE
OD 36, TEMPERATURE 1130 - 1200F
Pipe clamps, OD 36 (ND 900/36), types 44, 48
Type
44 91 51
44 91 52
44 91 53
44 91 54
44 91 55
Type
48 91 51
48 91 52
48 91 53
48 91 54
48 91 55
48 91 56

1130
15.7
23.8
33.7
39.8
47.4

permissible load (lbs x 1000)


1148 1166 1184 1200F
10.3
11.7
13.7
9.0
15.5
17.7
20.6
13.4
22.0
24.9
29.4
19.1
26.0
29.4
34.6
22.4
31.0
35.0
41.3
26.7

permissible load (lbs x 1000)


1130 1148 1166 1184 1200F
9.0
15.9 14.1 12.1 10.5
24.2 20.6 18.4 15.7 13.4
32.1 27.4 24.2 20.6 17.9
56.4 49.6 43.1 37.5 31.4
81.6 70.1 62.2 53.0 44.9
96.4 84.9 73.7 64.0 53.9

d3
2.00
2.40
2.80
2.80
2.80

max
B
12
10 7/8
10
12 1/4
14 1/8

E
34 1/4
35 1/4
35 5/8
36
35 7/8

max
ISO
12 5/8
12 5/8
12 5/8
12 5/8
12 5/8

L
d3
1.80
1.80
2.00
2.40
2.80
2.80

ER
11 3/4
13
13 3/4
15 1/8
18 1/2
17 3/4

dN
11
11
11
11
11
11

min.
67
67
67
67
71
71

lbs
718
903
1129
1308
1556
lbs

max.
98 1/2
98 1/2
98 1/2
98 1/2
98 1/2
98 1/2

min.
774
908
1115
1495
2022
2297

max.
1153
1390
1733
2300
2970
3310

load
group
6-9
7-10
8-30
8-30
9-30
load
group
5-8
5-8
6-9
7-10
8-30
9-30

Type 44

Type 48

LIFT-OFF RESTRAINT FOR


CLAMP BASES TYPE 49
Lift-off restraint for clamp
bases type 49
Type 49 00 01 to 49 00 04

Type
49 00 01
49 00 01
49 00 01
49 00 01
49 00 01
49 00 02
49 00 02
49 00 02
49 00 02
49 00 02
49 00 03
49 00 04

for clamp bases


49 01 11 to
49 01 12 to
49 01 25 to
49 01 35 to
49 01 45 to
49 19 13 to
49 16 14 to
49 13 25 to
49 07 35 to
49 13 45 to
49 36 13 to
49 56 13 to

49 17 11
49 14 12
49 11 25
49 06 35
49 11 45
49 32 13
49 32 14
49 32 25
49 32 35
49 32 45
49 51 45
49 91 45

1
1
1
1
1
2
2
2
2
2
3
4

3/
8
3/
8
3/
8
3/
8
3/
8
1/
8
1/
8
1/
8
1/
8
1/
8
1/
8
3/
8

5/
8
5/
8
5/
8
5/
8
5/
8
1/
4
1/
4
1/
4
1/
4
1/
4
3/
4

1
1
1
1
1
1
2

1
1
1
1
1
2
3

7/
8
7/
8
7/
8
7/
8
7/
8
3/
8
3/
8
3/
8
3/
8
3/
8
1/
8
1/
8

t
5/
16
5/
16
5/
16
5/
16
5/
16
1/
2
1/
2
1/
2
1/
2
1/
2
5/
8

a
weight/pair
leg length
(lbs)
3/
0.2
16
3/
0.2
16
3/
0.2
16
3/
0.2
16
3/
0.2
16
1/
0.6
4
1/
0.6
4
1/
0.6
4
1/
0.6
4
1/
0.6
4
5/
1.5
16
7/
4.0
16

The permissible occasional


lift-off load of the clamp
bases are 10% of the
catalog load.

Order details:
Lift-off restraint
Type 49 00 ..

4.54

CONNECTING PLATES
TYPE 77
Connecting plates for
coupling pipe clamps
Type 43
Type 77 09 39 to 77 19 39
Twice the specified load is
possible by coupling two
pipe clamps with Type 77.

Order details:
Connecting plate
Type 77 .. 39

Type

for clamps

77 09 39
77 17 39
77 19 39

43 01 19 up to 43 09 59
43 10 19 up to 43 17 59
43 19 19 up to 43 19 39, 43 19 59

Connecting plates for


coupling pipe clamps
Type 44, up to 1110F

load group

d3

D-5
3-6
4-7

1.00
1.34
1.80

2 1/2
2 3/4
3 1/2

3 1/2
3 1/2
3 1/2

weight
(lbs)
1.8
2.6
5.1

Type 60

Type 77 22 .. to 77 91 ..
Type designation of connecting
plates: the figures 44 of clamps to
be coupled are to be replaced by 77
e.g. connecting plate for
type 44 66 38
77 66 38.
 The load group for the upper
connection (Type 60) is to be
given when ordering

Order details:
Connecting plate
Type 77 .. .., load group ...

4.55

Type
77 22 .. up to 77 27 ..
77 32 .. up to 77 37 ..
77 41 .. up to 77 46 ..
77 51 .. up to 77 56 ..
77 61 .. up to 77 91 ..

load group 
5-10
5-30
6-30
7-50
7-50

d1
min max
2.37
1.30
2.76
1.30
2.76
1.58
3.55
1.78
3.55
1.78

E
5
5
5
7
7

3/
8
1/
2
1/
2
7/
8
1/
2

Bmax
7 1/8
8 7/8
10 7/8
11 7/8
12 3/4

weight
(lbs)
22-51
24-70
35-115
66-165
68-181

INSTALLATION INSTRUCTIONS

LISEGA pipe clamps and clamp bases are


supplied ready for use complete with all bolting required. The standard surface treatment
is outlined in Technical Specifications, page
0.11.
For safe operation and rational installation
the following points should be observed.
If stored in the open, components should be
protected from dirt and water.
Horizontal clamp type 42
This pipe clamp is used as a horizontal clamp
with eye nut type 60. When tightening bolting it must be ensured that the halves are
parallel to each other. Counter nuts are to
be used.
Horizontal clamp type 43
With this horizontal clamp, connection is
made via a separate connecting pin, with eye
nut type 60. It has to be made sure that the
pin is secured by the cotter pin provided.
Otherwise, proceed as with type 42.
Horizontal clamp type 44, U-bolt/strap
These horizontal clamps consist of an upper
part with connecting lug and, depending on
load or temperature range, of a U-bolt with
an inlay plate or strap as lower part. For
installation, the preassembled lower part is
taken off by loosening the fastening nuts or
removing the connecting pins. The upper
part is seated on top of the pipe and the
lower part fitted by screwing the U-bolt on or
pinning the flat steel strap on. After adjusting
the clamp, the connections are tightened.
The U-bolts are secured by counter nuts and
the flat steel straps by tab washers for the
hexagon nuts.
Pipe clamp type 44, over 1110F [600C]
These clamps consist of a yoke with connecting lug and restraint, as well as a flat steel
strap for the lower part. To install, the
restraint and strap are taken off by removing
the outer threaded rods and connecting
bolts.
The upper part is then fitted into the hanger.
The restraint and strap are fitted again, bolted on, and the threaded rods mounted.
All parts are to be checked for secure fit.

Riser clamp type 45


During installation, care must be taken to
place the spacers between the clamp halves
at the bolting. The bolting has to be tightened and secured by counter nuts.
The clamp is mounted via the other supporting pins, which are secured by washers and
cotter pins. The clamp is to be adjusted to
the height indicated by tightening the supporting boltings so that it is form fitted for
load actuation onto the shear lugs.
Riser clamp type 46
This clamp is supplied loose, sealed in plastic
foil.
For installation we recommend hanging the
front plates  in the supports first. The parts
to be tightened should be set at their lowest
level. Afterwards both side plates  can be
inserted in the intake slot. With heavy
clamps, the other side should be momentarily supported. Then the top plates  for
the shear lugs can be fitted and bolted on
by adjusting and tightening the preassembled securing plates .
By tightening the hanging parts the clamp is
to be adjusted to the height indicated and
form fitted for load actuation onto the shear
lugs.

Type 44 with U-bolt

Type 44 with strap




Type 44 over 1110F [600C]

 Type 46

4.56

Riser clamp type 48


This clamp is supplied loose, sealed in plastic
foil.

Type 49 .. .1 and 49 .. .2

First, one of the side plates  should be


prepared using threaded rods . For installation, both side plates are to be seated on
the trunnions and connected by the rods,
and the nuts only lightly tightened.

If required, the base plate may be welded


to the supporting surface.




Type 49 .. .3, 4

 Type 48

Type 49 .. .3, 4, 5

For heavy clamps, support with wooden


blocks or ropes is required.
The front plates  are now fitted into the
intake slots and connected to the hanging
parts. Secure connection of the front and
side plates is made by adjusting and tightening the preassembled securing plates .
By tightening the supports the clamp is to
be adjusted to the height indicated and
form fitted for load actuation to the trunnions.

4.57

Clamp bases type 49


LISEGA clamp bases are sliding supports,
connected to the pipe by clamping tension.
During installation it is essential that the
base plate lies flush and can glide unobstructed over the given stretches.

According to the particular field of application, different designs are used with regard
to support height, pipe diameter, support load
and operating temperature. The following
points are hereby to be observed:
Type 49 .. .1 and 49 .. .2
This clamp base consists of two halves to be
fitted to each side of the pipes. The cornered
ends form the base plate. In the lower
part, both halves are firmly connected to
each other by bolting. Through clamping
tension, the upper bolting secures the
clamp base against slipping.
Type 49 .. .3 and 49 .. .5
The foot of this clamp base forms a solid
support into which the pipe can be fitted.
The upper part, providing clamping tension,
consists of half a clamp and is to be securely
bolted.

You might also like