S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
V200R002C20
Hardware Description
Issue
03
Date
2014-11-05
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website:
http://enterprise.huawei.com
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Purpose
This document describes the hardware, device components, cables, environment requirements,
standard compliance and granted certifications of the storage system.
Intended Audience
This document is intended for:
l
Maintenance engineers
Content Conventions
The purchased products, services, and features are stipulated by the commercial contract made
between Huawei and the customer. All or partial products, services and features described in
this document may not be within the purchased scope or the usage scope. Unless otherwise
agreed by the contract, all statements, information, and recommendations in this document are
provided "AS IS" without warranties, guarantees, or representations of any kind, either express
or implied.
As part of an effort to improve and enhance the product performance and capabilities, Huawei
periodically releases revisions of the hardware and software. Therefore, some functions
described in this document may not be supported by all versions of the software or hardware
currently in use. For the up-to-date information about product features, refer to the product
release notes.
If a product does not function as described in this document, contact Huawei technical support
engineers.
Change History
Changes between document issues are cumulative. The latest document issue contains all the
changes made in earlier issues.
Issue 03 (2014-11-05)
ii
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Issue 01 (2014-05-30)
This is the first official release.
Issue 03 (2014-11-05)
iii
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Contents
Contents
About This Document.....................................................................................................................ii
1 Device Composition......................................................................................................................1
2 Hardware Introduction.................................................................................................................3
2.1 2 U Controller Enclosure................................................................................................................................................4
2.2 4 U Controller Enclosure................................................................................................................................................8
2.3 2 U SAS Disk Enclosure..............................................................................................................................................11
2.4 4 U SAS Disk Enclosure..............................................................................................................................................13
2.5 File Engine....................................................................................................................................................................15
2.6 Data Switch...................................................................................................................................................................17
2.7 4 U High-Density Disk Enclosure................................................................................................................................18
3 Device Components....................................................................................................................21
3.1 System Enclosure.........................................................................................................................................................23
3.2 Controller......................................................................................................................................................................26
3.3 Fan-BBU Module.........................................................................................................................................................31
3.4 Fan Module...................................................................................................................................................................32
3.5 BBU Module.................................................................................................................................................................36
3.6 Power Module...............................................................................................................................................................37
3.7 I/O Interface Module....................................................................................................................................................41
3.8 Management Module....................................................................................................................................................50
3.9 Expansion Module........................................................................................................................................................51
4 Indicator Introduction................................................................................................................56
4.1 Indicator Description (2 U Controller Enclosure)........................................................................................................57
4.2 Indicator Description (4 U Controller Enclosure)........................................................................................................64
4.3 Indicator Description (2 U SAS Disk Enclosure).........................................................................................................68
4.4 Indicator Description (4 U SAS Disk Enclosure).........................................................................................................70
4.5 Indicator Description (File Engine)..............................................................................................................................73
4.6 Indicator Description (Data Switch).............................................................................................................................76
4.7 Indicator Description (4 U High-Density Disk Enclosure)..........................................................................................78
5 Device Cables...............................................................................................................................82
5.1 Power Cable..................................................................................................................................................................83
Issue 03 (2014-11-05)
iv
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Contents
6 Environment Requirements......................................................................................................89
7 Standard Compliance.................................................................................................................92
8 Certifications................................................................................................................................96
9 Hardware Specifications..........................................................................................................101
A How to Obtain Help.................................................................................................................112
A.1 Preparations For Contacting Huawei.........................................................................................................................113
A.1.1 Collecting Troubleshooting Information................................................................................................................113
A.1.2 Making Debugging Preparations............................................................................................................................113
A.2 How to Use the Document.........................................................................................................................................113
A.3 How to Obtain Help from Website............................................................................................................................113
A.4 Ways to Contact Huawei...........................................................................................................................................114
B Glossary......................................................................................................................................115
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
1 Device Composition
Device Composition
The intelligent storage system consists of a controller enclosure and disk enclosures. The system
presents high reliability, blazing performance, and large capacity.
Different models use different controller enclosures and disk enclosures. Table 1-1 lists the
controller enclosures and disk enclosures used by each model.
Table 1-1 Controller enclosures and disk enclosures used by each model
Product
Model
Controller Enclosure
Disk Enclosure
Data Switch
S2600T
2 U 12-disk controller
enclosure
None
l 4 U High-Density disk
enclosure
S5500T
l 2 U 12-disk
controller enclosure
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
1 Device Composition
Product
Model
Controller Enclosure
Disk Enclosure
Data Switch
S5600T/
S5800T/
S6800T
4 U controller enclosure
l 4 U High-Density disk
enclosure
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
Hardware Introduction
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
Overall Structure
Figure 2-1 shows the overall structure of a 2 U 24-disk controller enclosure, Figure 2-2 shows
the overall structure of a 2 U 12-disk controller enclosure (S5500T), and Figure 2-3 shows the
overall structure of the 2 U 12-disk controller enclosure (S2600T).
Figure 2-1 Overall structure of the 2 U 24-disk controller enclosure
System enclosure
Power module
Fan-BBU module
Controller
Disk module
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
System enclosure
Power module
Fan-BBU module
Controller
Disk module
System enclosure
Power module
Fan-BBU module
Controller
Disk module
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
Front View
Figure 2-4 shows the front view of a 2 U 24-disk controller enclosure, Figure 2-5 shows the
front view of a 2 U 12-disk controller enclosure (S5500T), and Figure 2-6 shows the front view
of a 2 U 12-disk controller enclosure (S2600T).
Figure 2-4 Front view of a 2 U 24-disk controller enclosure
System enclosure
NOTE
The disk slots of a 2 U 24-disk controller enclosure are numbered 0 to 23 from left to right. The four coffer
disks are located in slot 0 to slot 3.
System enclosure
NOTE
The disk slots of a 2 U 12-disk controller enclosure are numbered 0 to 11 from left to right and from top
to bottom. The four coffer disks are located in slot 0 to slot 3.
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
USB port
System enclosure
NOTE
The disk slots of a 2 U 12-disk controller enclosure are respectively numbered as 0 to 11 from left to right
and from top to bottom. The four coffer disks are located in slot 0 to slot 3.
Rear View
Figure 2-7 shows the rear view of a 2 U controller enclosure (S5500T), and Figure 2-8 shows
the rear view of a 2 U controller enclosure (S2600T).
NOTE
The storage system supports 1 Gbit/s iSCSI interface module, 10 Gbit/s TOE interface module, 10 Gbit/s
FCoE interface module, and 8 Gbit/s Fibre Channel interface module. The preceding figure uses an 8 Gbit/
s Fibre Channel interface module as an example.
System enclosure
Power module
Fan-BBU module
Controller handle
Serial port
10
Controller
11
12
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
13
15
2 Hardware Introduction
14
NOTE
The storage system supports 1 Gbit/s iSCSI interface module, 10 Gbit/s TOE interface module, and 8 Gbit/
s Fibre Channel interface module. The preceding figure uses an 8 Gbit/s Fibre Channel interface module
as an example.
Serial port
Controller
10
11
12
Controller handle
13
Fan-BBU module
14
Power module
15
System enclosure
Overall Structure
Figure 2-9 shows the overall structure of a 4 U controller enclosure.
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
System enclosure
Controller
BBU module
Fan module
Power module
Interface module
Front View
Figure 2-10 shows the front view of a 4 U controller enclosure.
Issue 03 (2014-11-05)
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
System enclosure
Controller handle
Controller
BBU module
Rear View
Figure 2-11 shows the rear view of the controller enclosure.
Figure 2-11 Rear view of the controller enclosure (S5600T)
System enclosure
Fan module
Power module
Issue 03 (2014-11-05)
10
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
13 Serial port
NOTE
You can configure a controller enclosure with the following types of interface module:
l Management module (mandatory, used for management).
l 6 Gbit/s SAS expansion module (mandatory, used for connecting to disk enclosures).
l 1 Gbit/s iSCSI interface module, 8 Gbit/s Fibre Channel interface module, 10 Gbit/s TOE interface
module, 10 Gbit/s FCoE interface module (optional, choose at least one of the preceding interface
modules, used for connecting to application servers).
l 5 Gbit/s PCIe interface modules (in slots A3 and B3): used for connecting controller enclosure.
Overall Structure
Figure 2-12 shows the overall structure of a 2 U SAS disk enclosure.
Figure 2-12 Overall structure of a 2 U SAS disk enclosure
Issue 03 (2014-11-05)
System enclosure
Power module
11
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3
Fan module
Disk module
2 Hardware Introduction
4
Expansion module
Front View
Figure 2-13 shows the front view of the 2 U SAS disk enclosure.
Figure 2-13 Front view of the disk enclosure
System enclosure
Rear View
Figure 2-14 shows the rear view of the 2 U SAS disk enclosure.
Figure 2-14 Rear view of the disk enclosure with AC power modules
System enclosure
Serial port
Power module
Expansion module
10
11
Fan module
12
Issue 03 (2014-11-05)
12
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
Structure
Figure 2-15 shows the overall structure of a 4 U SAS disk enclosure.
Figure 2-15 Overall structure of a 4 U SAS disk enclosure
System enclosure
AC power module
Fan module
Expansion module
Disk module
Front View
Figure 2-16 shows the front view of the 4 U SAS disk enclosure.
Issue 03 (2014-11-05)
13
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
System enclosure
Rear View
Figure 2-17 shows the rear view of a 4 U SAS disk enclosure.
Figure 2-17 Rear view of a 4 U SAS disk enclosure
System enclosure
Expansion module
Serial port
10
Fan module
11
Power module
12
Issue 03 (2014-11-05)
14
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
Overall Structure
Figure 2-18 shows the overall structure of the file engine.
Figure 2-18 Overall structure of the file engine configured with AC power modules
System enclosure
Controller
Fan module
Power module
Interface module
Front View
Figure 2-19 shows the front view of the file engine.
Issue 03 (2014-11-05)
15
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
System enclosure
Controller handle
Controller
Power button
Filler panel
Rear View
Figure 2-20 shows the rear view of the file engine.
Figure 2-20 Rear view of the file engine
System enclosure
Fan module
Issue 03 (2014-11-05)
16
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
Power module
12 Serial port
Structure
Figure 2-21 shows the overall structure of a data switch.
Figure 2-21 Overall structure of a data switch
System enclosure
Fan module
AC power module
Front View
Figure 2-22 shows the front view of data switch.
Issue 03 (2014-11-05)
17
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
AC power module
Fan module
Rear View
Figure 2-23 shows the rear view of a data switch.
Figure 2-23 Rear view of a data switch
Power socket
PCIe port
Serial port
Overall Structure
Figure 2-24 shows the overall structure of a high-density disk enclosure.
NOTE
The high-density disk enclosure is configured four 800 W power modules, the voltage input scope is from
100 V to 127 V and from 200 V to 240 V.
Issue 03 (2014-11-05)
18
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
Figure 2-24 Overall structure of a high-density disk enclosure with four 800 W power modules
System enclosure
Power module
Fan module
Expansion module
Disk module
Front View
Figure 2-25 shows the front view of a high-density disk enclosure.
Figure 2-25 Front view of a high-density disk enclosure
Captive screw
Handle
Rear View
Figure 2-26 shows the rear view of a high-density disk enclosure with four 800 W power
modules.
Issue 03 (2014-11-05)
19
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
2 Hardware Introduction
Figure 2-26 Rear view of a high-density disk enclosure with four 800 W power modules
Power module
Fan module
Expansion module
10
11
12
13
14
Serial port
Issue 03 (2014-11-05)
20
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Device Components
21
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
A management module provides a management network port, a maintenance network port, and
a serial port. The management module saves system configuration data, alarm data, and log data
onto solid-state drive (SSD) coffer disks.
3.9 Expansion Module
An expansion module provides expansion ports that are used for communication between a
controller enclosure and a disk enclosure. The module transfers data between a controller
enclosure and a disk enclosure.
Issue 03 (2014-11-05)
22
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Issue 03 (2014-11-05)
23
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Issue 03 (2014-11-05)
24
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
25
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
3.2 Controller
A controller is a core component of the storage system. It is responsible for processing storage
services, receiving configuration and management commands from users, and saving the
configuration information, managing disks, and storing critical data onto the coffer disks.
Issue 03 (2014-11-05)
26
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Controller handle
Table 3-1 lists the states and corresponding meanings of indicators on a controller of a 4 U
controller enclosure after the controller enclosure is powered on.
Table 3-1 Checklist for indicators on a controller of a 4 U controller enclosure
No.
Indicator Name
Controller Power
indicator
Controller Alarm
indicator
Issue 03 (2014-11-05)
27
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
1 Controller handle
6 Serial port
Table 3-2 lists the states and corresponding meanings of indicators on a controller of a 2 U
controller enclosure (S2600T) after the controller enclosure is powered on.
Table 3-2 Checklist for the indicators on the rear panel of a controller enclosure (S2600T)
No.
Indicator
Link/Active indicator of
the management network
port
Link/Active indicator of
the 1 Gbit/s iSCSI port
Issue 03 (2014-11-05)
28
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
No.
Indicator
11
12
Link/Speed indicator of an
8 Gbit/s Fibre Channel
port
13
Controller Alarm
indicator
14
Controller Power
indicator
15
17
29
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
16 Controller handle
Table 3-3 lists the states and corresponding meanings of indicators on a controller of a 2 U
controller enclosure (S5500T) after the controller enclosure is powered on.
Table 3-3 Checklist for indicators on a controller of a 2 U controller enclosure (S5500T)
No.
Indicator Name
Link/Speed indicator
of the 8 Gbit/s Fibre
Channel port
10
30
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
No.
Indicator Name
11
Controller Alarm
indicator
12
Controller Power
indicator
13
Module Power
indicator
15
Issue 03 (2014-11-05)
31
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-4 lists the states and corresponding meanings of the fan-BBU indicator after it is
powered on.
Table 3-4 Checklist for the fan-BBU module indicator
No.
Indicator Name
Fan-BBU Running/
Alarm indicator
Issue 03 (2014-11-05)
32
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-5 lists the states and corresponding meanings of the fan module indicator after it is
powered on.
Table 3-5 Checklist for the fan module indicator
No.
Indicator Name
Issue 03 (2014-11-05)
33
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-6 lists the states and corresponding meanings of the fan module indicator after it is
powered on.
Table 3-6 Checklist for the fan module indicator
No.
Indicator Name
Issue 03 (2014-11-05)
34
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-7 lists the states and corresponding meanings of the fan module indicator after it is
powered on.
Table 3-7 Checklist for the fan module indicator
No.
Indicator Name
Issue 03 (2014-11-05)
35
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-8 lists the states and corresponding meanings of the fan module indicator after it is
powered on.
Table 3-8 Checklist for the fan module indicator
No.
Indicator Name
Issue 03 (2014-11-05)
36
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-9 lists the states and corresponding meanings of the BBU module indicator after it is
powered on.
Table 3-9 Checklist for the BBU module indicator
No.
Indicator Name
BBU Running/Alarm
indicator
Power Module for a Disk Enclosure and a 4 U Controller and File Engine
Figure 3-17 shows an AC power module of a 4 U controller enclosure and file engine and disk
enclosure.
Issue 03 (2014-11-05)
37
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Figure 3-17 AC power module of a 4 U controller enclosure and file engine and disk enclosure
Table 3-10 lists the states and corresponding meanings of indicators on a power module for a
disk enclosure or 4 U controller enclosure after it is powered on.
Table 3-10 Checklist for indicators on a power module for a disk enclosure or 4 U controller
enclosure
No.
Indicator Name
38
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-11 lists the states and corresponding meanings of indicators on a power module for a
disk enclosure or 4 U controller enclosure after it is powered on.
Table 3-11 Checklist for indicators on a power module for a disk enclosure or 4 U controller
enclosure
No.
Indicator Name
Issue 03 (2014-11-05)
39
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-12 lists the states and corresponding meanings of indicators on a power module for a
data switch after it is powered on.
Table 3-12 Checklist for indicators on a power module for a data switch
No.
Indicator
Issue 03 (2014-11-05)
40
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-13 lists the states and corresponding meanings of indicators on a power module for a
high-density disk enclosure after it is powered on.
Table 3-13 Checklist for indicators on a power module for a high-density disk enclosure
No.
Indicator
41
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
port rate and the port mode is set to autonegotiation, the port automatically adjusts its rate to
ensure the connectivity of the data transfer channel and the consistency of the data transfer rate.
Figure 3-21 shows an 8 Gbit/s Fibre Channel interface module.
Figure 3-21 8 Gbit/s Fibre Channel interface module
4 Module handle
Table 3-14 lists the states and corresponding meanings of indicators on an 8 Gbit/s Fibre Channel
interface module after it is powered on.
Table 3-14 Checklist for indicators on an 8 Gbit/s Fibre Channel interface module
No.
Indicator Name
Issue 03 (2014-11-05)
42
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
No.
Indicator Name
Link/Speed indicator of an
8 Gbit/s Fibre Channel
port
4 Module handle
Table 3-15 lists the states and corresponding meanings of indicators on a 16 Gbit/s Fibre Channel
interface module after it is powered on.
Issue 03 (2014-11-05)
43
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-15 Checklist for indicators on a 16 Gbit/s Fibre Channel interface module
No.
Indicator Name
Link/Speed indicator of a
16 Gbit/s Fibre Channel
port
Issue 03 (2014-11-05)
44
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Link/Active indicator of a 1 Gbit/s iSCSI port
3 Device Components
4 Speed indicator of a 1 Gbit/s iSCSI port
5 Module handle
Table 3-16 lists the states and corresponding meanings of indicators on a 1 Gbit/s iSCSI interface
module after it is powered on.
Table 3-16 Checklist for indicators on a 1 Gbit/s iSCSI interface module
No.
Indicator Name
Link/Active indicator of a
1 Gbit/s iSCSI port
Speed indicator of a 1
Gbit/s iSCSI port
Issue 03 (2014-11-05)
45
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
4 Module handle
Table 3-17 lists the states and corresponding meanings of indicators on a 10 Gbit/s TOE interface
module after it is powered on.
Table 3-17 Checklist for indicators on a 10 Gbit/s TOE interface module
No.
Indicator Name
Link/Speed indicator of a
10 Gbit/s TOE port
46
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
4 Module handle
Table 3-18 lists the states and corresponding meanings of indicators on a 10 Gbit/s FCoE
interface module after it is powered on.
Table 3-18 Checklist for indicators on a 10 Gbit/s FCoE interface module
No.
Indicator Name
Link/Speed indicator of a
10 Gbit/s FCoE port
Issue 03 (2014-11-05)
47
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
4 Module handle
Table 3-19 lists the states and corresponding meanings of indicators on a 10 Gbit/s FCoE
interface module after it is powered on.
Table 3-19 Checklist for indicators on a 10 Gbit/s FCoE interface module
No.
Indicator Name
Link/Speed indicator of a
10 Gbit/s FCoE port
Issue 03 (2014-11-05)
48
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
4 Module handle
Table 3-20 lists the states and corresponding meanings of indicators on a 5 Gbit/s PCIe interface
module after it is powered on.
Table 3-20 Checklist for indicators on a 5 Gbit/s PCIe interface module
No.
Indicator Name
Link/Speed indicator of a
5 Gbit/s PCIe port
Issue 03 (2014-11-05)
49
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
4 Serial port
7 Module handle
Table 3-21 lists states and corresponding meanings of indicators on the management module
after it is powered on.
Table 3-21 Checklist for management module indicators
No.
Indicator Name
Issue 03 (2014-11-05)
50
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
No.
Indicator Name
4 Module handle
Table 3-22 lists the states and corresponding meanings of indicators on a 6 Gbit/s SAS expansion
module after it is powered on.
Issue 03 (2014-11-05)
51
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Indicator Name
Issue 03 (2014-11-05)
52
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
5 Serial port
Table 3-23 lists the states and corresponding meanings of indicators on an expansion module
for a disk enclosure.
Table 3-23 Checklist for indicators on an expansion module for a disk enclosure
No.
Indicator Name
Issue 03 (2014-11-05)
53
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
7 Serial port
Table 3-24 lists the states and corresponding meanings of indicators on an expansion module
for a high-density disk enclosure.
Issue 03 (2014-11-05)
54
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Device Components
Table 3-24 Checklist for indicators on an expansion module for a high-density disk enclosure
No.
Indicator Name
Issue 03 (2014-11-05)
55
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Indicator Introduction
Issue 03 (2014-11-05)
56
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-1 describes the indicators on the front panel of a controller enclosure.
Table 4-1 Description of the indicators on the front panel of a controller enclosure
Module
No.
Indicator
System
enclosure
Controller enclosure
Location indicator
Disk
module
Issue 03 (2014-11-05)
57
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Module
No.
Indicator
System
enclosure
Controller enclosure
Power indicator
Controller enclosure
Alarm indicator
Table 4-2 describes the indicators on the front panel of a controller enclosure.
Issue 03 (2014-11-05)
58
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-2 Description of the indicators on the front panel of a controller enclosure
Module
No.
Indicator
System
enclosure
Controller enclosure
Power indicator
Disk module
Disk module
Running indicator
System
enclosure
Controller enclosure
Alarm indicator
Table 4-3 describes the indicators on the rear panel of a controller enclosure.
Issue 03 (2014-11-05)
59
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-3 Description of the indicators on the rear panel of a controller enclosure
Module
No.
Indicator
Power
module
Fan-BBU
module
Fan-BBU module
Running/Alarm indicator
Controller
Link/Active indicator of
the 1 Gbit/s iSCSI port
Issue 03 (2014-11-05)
60
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Module
4 Indicator Introduction
No.
Indicator
Link/Speed indicator of an
8 Gbit/s Fibre Channel
port
Issue 03 (2014-11-05)
61
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Module
4 Indicator Introduction
No.
Indicator
10
Link/Active indicator of
the management network
port
Table 4-4 describes the indicators on the rear panel of a controller enclosure.
Table 4-4 Description of the indicators on the rear panel of a controller enclosure
Module
No.
Indicator
Power module
Power module
Running/Alarm
indicator
Issue 03 (2014-11-05)
62
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Module
No.
Indicator
Fan-BBU
module
Fan-BBU Running/
Alarm indicator
Interface module
Link/Speed indicator
of an 8 Gbit/s Fibre
Channel port
Controller
Controller Alarm
indicator
Controller Power
indicator
Indicator of a mini
SAS expansion port
Issue 03 (2014-11-05)
63
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Module
4 Indicator Introduction
No.
Indicator
Active indicator of
the management
network port
Table 4-5 describes the indicators on the front panel of a controller enclosure.
Issue 03 (2014-11-05)
64
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-5 Description of the indicators on the front panel of a controller enclosure
Module
No.
Indicator
System
enclosure
Controller enclosure
Power indicator
Controller
Controller Power
indicator
Controller Alarm
indicator
BBU module
System
enclosure
Controller enclosure
Alarm indicator
Issue 03 (2014-11-05)
65
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-6 describes the indicators on the rear panel of a controller enclosure.
Table 4-6 Description of the indicators on the rear panel of a controller enclosure
Module
No.
Indicator
Power
module
Power module
Running/Alarm
indicator
Fan module
Fan module
Running/Alarm
indicator
Interface
module
Link/Active
indicator of the 1
Gbit/s iSCSI port
Issue 03 (2014-11-05)
66
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Module
4 Indicator Introduction
No.
Indicator
Link/Speed
indicator of the
Fibre Channel port
Module Power
indicator
Active indicator of
the management
network port
Link indicator of
the management
network port
Speed indicator of
the 1 Gbit/s iSCSI
port
Indicator of a 10
Gbit/s TOE port
Issue 03 (2014-11-05)
67
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Module
4 Indicator Introduction
No.
Indicator
10
Indicator of a mini
SAS expansion
port
Table 4-7 describes the indicators on the front panel of a disk enclosure.
Table 4-7 Description of the indicators on the front panel of a disk enclosure
Module
No.
Indicator
System
enclosure
Disk enclosure
Power indicator
Issue 03 (2014-11-05)
68
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Module
No.
Indicator
Disk module
Disk module
Running indicator
Disk module
Alarm/Location
indicator
System
enclosure
Disk enclosure
Alarm indicator
Table 4-8 describes the indicators on the rear panel of a disk enclosure.
Issue 03 (2014-11-05)
69
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-8 Description of the indicators on the rear panel of a disk enclosure
Module
No.
Indicator
Power module
Power module
Running/Alarm
indicator
Fan module
Fan module
Running/Alarm
indicator
Expansion
module
Indicator of a mini
SAS expansion
port
Expansion module
Alarm indicator
Expansion module
Power indicator
70
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-9 describes the indicators on the front panel of a disk enclosure.
Table 4-9 Description of the indicators on the front panel of a disk enclosure
Module
No.
Indicator
System
enclosure
Disk enclosure
Power indicator
Disk module
Disk module
Running indicator
Disk module
Alarm/Location
indicator
System
enclosure
Disk enclosure
Alarm indicator
Issue 03 (2014-11-05)
71
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-10 describes the indicators on the rear panel of a disk enclosure.
Table 4-10 Description of the indicators on the rear panel of a disk enclosure
Module
No.
Indicator
Power module
Power module
Running/Alarm
indicator
Fan module
Fan module
Running/Alarm
indicator
Issue 03 (2014-11-05)
72
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Module
No.
Indicator
Expansion
module
Indicator of a mini
SAS expansion
port
Expansion module
Alarm indicator
Expansion module
Power indicator
Table 4-11 describes the indicators on the front panel of a file engine.
Issue 03 (2014-11-05)
73
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-11 Description of the indicators on the front panel of a file engine
Module
No.
Indicator
System
enclosure
Power indicator
of the file engine
Controller
Controller Power
indicator
Controller Alarm
indicator
System
enclosure
Power Alarm
indicator of the
file engine
Issue 03 (2014-11-05)
74
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-12 describes the indicators on the rear panel of a file engine.
Table 4-12 Description of the indicators on the rear panel of a file engine
Module
No.
Indicator
Power module
Power module
Running/Alarm
indicator
Fan module
Fan module
Running/Alarm
indicator
Interface
module
Link/Active
indicator of a 1
Gbit/s iSCSI port
Management
module
Interface
module
Active indicator
of the
management
network port
Link indicator of
the management
network port
Issue 03 (2014-11-05)
75
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Module
4 Indicator Introduction
No.
Indicator
Link/Speed
indicator of an 8
Gbit/s FC port
Front View
Figure 4-14 shows the front view of data switch.
Figure 4-14 Front view of data switch
Table 4-13 lists the states and corresponding meanings of indicators on a data switch.
Table 4-13 Checklist for indicators on a data switch
No.
Indicator Name
Issue 03 (2014-11-05)
76
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
No.
Indicator Name
Power Running/Alarm
indicator
Fan Running/Alarm
indicator
Rear View
Figure 4-15 shows the rear view of a data switch.
Figure 4-15 Rear view of a data switch
Table 4-14 lists the states and corresponding meanings of indicators on a data switch.
Table 4-14 Checklist for indicators on a data switch
No.
Indicator Name
Issue 03 (2014-11-05)
77
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
No.
Indicator Name
Link/Speed indicator of a
PCIe port
Table 4-15 describes the indicators on the front panel of a high-density disk enclosure.
Table 4-15 Description of the indicators on the front panel of a high-density disk enclosure
Issue 03 (2014-11-05)
Module
No.
Indicator
System
enclosure
High-density disk
enclosure
Location
indicator
78
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Module
4 Indicator Introduction
No.
Indicator
High-density disk
enclosure
overtemperature
Alarm indicator
l Steady red: The temperature of the highdensity disk enclosure is too high.
High-density disk
enclosure internal
module Alarm
indicator
l Steady red: Internal disk modules of the highdensity disk enclosure are faulty.
High-density disk
enclosure rear
module Alarm
indicator
High-density disk
enclosure Power
indicator
High-density disk
enclosure Alarm
indicator
Issue 03 (2014-11-05)
79
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Table 4-16 describes the indicators on the rear panel of a high-density disk enclosure.
Table 4-16 Description of the indicators on the front panel of a high-density disk enclosure
Module
No.
Indicator
Power
module
Expansion
module
Fan
module
Issue 03 (2014-11-05)
80
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
4 Indicator Introduction
Module
No.
Indicator
Expansion
module
Indicator
Disk
module
Issue 03 (2014-11-05)
81
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
5 Device Cables
Device Cables
The cable specifications vary according to the installation site. This chapter uses only one type of
specifications for each device cable type as an example.
Issue 03 (2014-11-05)
82
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
5 Device Cables
Issue 03 (2014-11-05)
83
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
5 Device Cables
Connect the controller enclosure through a 1 Gbit/s iSCSI port to an application server
Direct-connection networking
One end of the network cable is connected to the iSCSI port of the controller enclosure
and the other end to the NIC port of the application server.
GE switch networking
One end of a network cable is connected to the iSCSI port on the controller enclosure
and the other end to a port on a GE switch. One end of another network cable is connected
to another port on the GE switch and the other end to the NIC port of the application
server.
84
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
5 Device Cables
Issue 03 (2014-11-05)
85
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
5 Device Cables
86
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
5 Device Cables
An optical fiber connects the controller enclosure to an application server through a port.
l
Direct-connection networking
One end of the optical fiber is connected to the Fibre Channel port of the controller
enclosure and the other end to the Fibre Channel HBA port of the application server.
One end of the optical fiber is connected to the 10 Gbit/s TOE port or 10 Gbit/s FCoE
port of the controller enclosure and the other end to the 10GE HBA port of the
application server.
NOTE
The storage system does not support single-mode optical fibers or single-mode optical transceivers.
Issue 03 (2014-11-05)
87
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
5 Device Cables
Issue 03 (2014-11-05)
88
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
6 Environment Requirements
Environment Requirements
The chapter describes the environment requirements that ensure the normal running of devices,
including the temperature and humidity, altitude, heat dissipation and air flow, and noise of
storage devices.
Condition
Requirement
Temperature
Operating temperature
Humidity
Storage temperature
Operating humidity
5% RH to 90% RH
Storage humidity
5% RH to 95% RH
Issue 03 (2014-11-05)
Parameter
Requirement
Particle Contaminants
89
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
6 Environment Requirements
Parameter
Requirement
To control particle and corrosive airborne contaminants under the density limits, perform the
following operations:
l
Do not set up the equipment room in an area with a high corrosive air density, such as a
chemical factory.
Do not make the entrance of the equipment room face a pollution source.
Use an effective filter to process the air flowing into the equipment room, and a filtering
system to periodically clean the air already in the equipment room.
Use environment-friendly heat insulation rather than sulfurated rubber and plastic heat
installation.
Keep unused batteries away from devices. It is recommended to keep unused batteries in
different rooms.
The controller enclosure adopts the heat dissipation mode of front absorption and back
dissipation.
The cool air enters from the gaps between the front controllers or BBUs and the rear
modules in the controller enclosure, passes through the midplane (the air from the modules
whirls and converges with the air from the front inlet of the midplane), cools the power
modules, controllers, and interface modules, and then is discharged by the fans. The
controller enclosure automatically adjusts the rotation speed of the fans according to the
operating temperature, thus ensuring heat dissipation for the system.
The disk enclosure adopts the heat dissipation mode of front absorption and back
dissipation.
The cool air enters from the gaps between the disks, passes through the midplane into the
power modules and expansion modules area, cools the power modules and expansion
modules, and is discharged by the fans. The disk enclosure automatically adjusts the
Issue 03 (2014-11-05)
90
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
6 Environment Requirements
rotation speed of the fans according to the operating temperature, thus ensuring heat
dissipation for the system.
For better maintenance, ventilation, and heat dissipation, pay attention to the following when
installing the storage system to the cabinet:
l
To ensure smooth ventilation, the cabinet should be at least 100 cm (39.4 inch) away from
the walls and at least 120 cm (47.28 inch) away from another cabinet (in front of or behind
this one).
To keep air convecting between the cabinet and the equipment room, no enclosed space is
allowed in the cabinet. 1U (44.45 mm, 1.75 inch) space should be left above and below
each device.
Noise
Table 6-3 lists the maximum noise generated by the storage system when the ambient
temperature is 25C (77F).
Table 6-3 Noise parameters of the storage system
Issue 03 (2014-11-05)
Parameter
Value
Noise power
< 72 dBA
91
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
7 Standard Compliance
Standard Compliance
The chapter describes the protocol standards, the safety specifications and electromagnetic
compatibility (EMC) standards, the industry standards that the storage system complies with.
Protocol Standards
Table 7-1 lists the protocol standards that the storage system complies with.
Table 7-1 Protocol standards
Name
Standard No.
SCSI system
Issue 03 (2014-11-05)
92
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Name
7 Standard Compliance
Standard No.
SFF 8301 form factor of 3.5' disk drive
SFF 8323 3.5' disk drive form factor with serial connector
SFF 8482 SAS plug connector
SCSI 3 SAM-2: ANSI INCITS 366-2003
SPC-2: ANSI INCITS 351-2001
SBC: ANSI INCITS 306-1998
PICMG3.0 Advanced Telecommunications Computing
Architecture
PICMG3.1 Ethernet/fiber Channel Over PICMG3.0
TCP/IP system
SNMP v1
SNMP v2c
SNMP v3
PCIe system
Standard No.
GB 4943
UL 60950-1
LVD 2006/95/EC
EN 60950-1
ICES-003: 2004
CAN/CSA-CEI/IEC CISPR 22:02
Issue 03 (2014-11-05)
93
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Name
Standard No.
EN 55022
7 Standard Compliance
EN 61000-3-2
EN 61000-3-3
ETSI EN 300 386
EN 55024
Japan standard
VCCI V-3
Australia standard
AS/NZS CISPR 22
Industry Standards
Table 7-3 lists the industry standards that the storage system complies with.
Table 7-3 Industry standards
Name
Standard No.
Ethernet
IEEE 802.3
Fast Ethernet
IEEE 802.3u
Gigabit Ethernet
IEEE 802.3z
IEEE 802.3ab
Issue 03 (2014-11-05)
10-Gigabit Ethernet
IEEE 802.3ae
IEEE 1149.1-2001
IEC 812
Presentation of reliability,
maintainability and
availability predictions
IEC 863
ETSI standard
(environment)
94
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Issue 03 (2014-11-05)
7 Standard Compliance
Name
Standard No.
ETSI standard
(environment)
ITUT K.27
Environmental protection
ECMA TR/70
Reliability
95
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
8 Certifications
Certifications
The chapter describes the certifications that the storage system passes.
Table 8-1 lists the reliability certifications that the storage system passes.
Table 8-1 Reliability certifications
Name
Icon
Description
CB
None
Issue 03 (2014-11-05)
96
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Name
Icon
CCC
8 Certifications
Description
CCC stands for China Compulsory
Certification.
According to Regulations on
Compulsory Product Certification
issued by General Administration of
Quality Inspection, Supervision and
Quarantine of the People's Republic of
China, Certification and Accreditation
Administration of the People's
Republic of China organizes and
implements CCC of products related to
human health and safety, animal and
plant life and health, environmental
protection, and public security.
FCC
None
IC
None
UL
Issue 03 (2014-11-05)
97
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Name
CE
Icon
8 Certifications
Description
Conformite Europeenne (CE):
Products marked with CE conform to
EMC (2004/108/EC) and low-voltage
(2006/95/EC) specifications published
by EU.
If this product has telecommunication
functionality, the R_TTE Directive
(1999/5/EC) that complies with the
directives mentioned previously
implies conformity to the following
European norms (in parentheses are the
equivalent international standards and
regulations):
l EN 55022 (CISPR 22)-Electro
Magnetic Interference
l EN 55024 (IEC61000-4-2, 3, 4, 5,
6, 8, 11)-Electro Magnetic
Immunity
l EN 60950 (IEC 60950)-Product
Safety
Issue 03 (2014-11-05)
CU
C-TICK
98
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
8 Certifications
Name
Icon
Description
SONCAP
None
SASO
None
Mexico
COC
None
VCCI
None
Table 8-2 lists the environmental protection certifications that the storage system complies with.
Issue 03 (2014-11-05)
99
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
8 Certifications
Icon
Description
REACH
None
RoHS
WEEE
Issue 03 (2014-11-05)
100
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
9 Hardware Specifications
Hardware Specifications
Issue 03 (2014-11-05)
Category
Description
Hardware
configuration
Port
specifications
Disk
specifications
Dimensions and
weight
Electrical
specifications
Reliability
specifications
101
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
9 Hardware Specifications
Hardware Configuration
Item
S2600T
S5500T
S5600T
S5800T
S6800T
Processor
(per
controller)
1 x processors
1 x dual-core
processors
1 x quadcore
processors
2 x quadcore
processor
s
2 x hexcore
processor
s
Memory
capacity
(per
controller)
8 GB
8 GB/16 GB
12 GB/24
GB
48 GB/96
GB
96 GB/
192 GB
Maximum
number of
controllers
Maximum
number of
disks
276
528
1152
1440
1440
Controller
enclosure
configurati
on
12 x 3.5-inch
disks per 2 U
controller
enclosure
l 24 x 2.5-inch
disks per 2 U
controller
enclosure
l 12 x 3.5-inch
disks per 2 U
controller
enclosure
Issue 03 (2014-11-05)
Supported
disk
enclosure
types
l 4 U SAS disk
enclosure
Supported
disk types
Supported
front-end
hosts and
hotswappable
interface
modules
l 8 Gbit/s Fibre
Channel
l 16 Gbit/s
Fibre Channel
l 1 Gbit/s GE
l 1 Gbit/s GE
l 10 Gbit/s TOE
102
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
9 Hardware Specifications
Item
S2600T
S5500T
S5600T
S5800T
Number of
supported
hotswappable
interface
modules
(per
controller)
S6800T
Port Specifications
Issue 03 (2014-11-05)
Port
Specificati
ons
S2600T
S5500T
Maximum
number of
ports
provided by
each 8 Gbit/s
Fibre
Channel
interface
module
4 x front-end ports
Maximum
number of 8
Gbit/s Fibre
Channel
ports (per
controller)
Maximum
number of
ports
provided by
each 16 Gbit/
s Fibre
Channel
interface
module
2 x front-end ports
Maximum
number of 16
Gbit/s Fibre
Channel
ports (per
controller)
S5600T
S5800T
16
20
10
S6800T
103
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Port
Specificati
ons
S2600T
Maximum
number of
ports
provided by
each 1 Gbit/s
GE interface
module
4 x front-end ports
Maximum
number of 1
Gbit/s GE
ports (per
controller)
10
Maximum
number of
ports
provided by
each 10 Gbit/
s TOE
interface
module
4 x front-end ports
Maximum
number of 10
Gbit/s TOE
ports (per
controller)
Maximum
number of
ports
provided by
each 10 Gbit/
s FCoE
interface
module (four
ports)
4 x front-end ports
Maximum
number of 10
Gbit/s FCoE
ports (per
controller)
Issue 03 (2014-11-05)
S5500T
9 Hardware Specifications
S5600T
S5800T
16
20
16
20
16
S6800T
20
104
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Port
Specificati
ons
S2600T
S5500T
Maximum
number of
ports
provided by
each 10 Gbit/
s FCoE
interface
module (two
ports)
2 x front-end ports
Maximum
number of 10
Gbit/s FCoE
ports (per
controller)
Maximum
number of
ports
provided by
each 5 Gbit/s
PCIe
interface
module
Maximum
number of 5
Gbit/s PCIe
ports (per
controller)
Issue 03 (2014-11-05)
9 Hardware Specifications
S5600T
S5800T
S6800T
10
Maximum
number of
ports
provided by
each 6 Gbit/s
SAS
expansion
module
2 x back-end ports
Maximum
number of
mini SAS
expansion
ports (per
controller)
10
105
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
9 Hardware Specifications
Port
Specificati
ons
S2600T
S5500T
S5600T
S5800T
Maximum
number of
disk
enclosures
l Disk
enclosure
(24
disks): 11
l Disk
enclosure
(24
disks): 22
l Disk
enclosure
(24
disks): 48
l Highdensity
disk
enclosure
:3
l Highdensity
disk
enclosure
:7
l Highdensity
disk
enclosure
: 15
Length of an
expansion
SAS cable
S6800T
l High-density disk
enclosure: 19
Disk Specifications
Disk
Type
Dimens
ions
Rotational
Speed
Weight
Power
Consumption
(Working/Idle)
Capacity
SAS
3.5
inches
15k rpm
0.8 kg
(1.76 lb)
18 W/14 W
300 GB/600 GB
2.5
inches
10k rpm
0.21 kg
(0.46 lb)
7.9 W/4.4 W
NLSAS
3.5
inches
7.2k rpm
0.72 kg
(1.59 lb)
12.8 W/8.6 W
2 TB/3 TB/4 TB
SSD
2.5
inches
0.19 kg
(0.42 lb)
9.48 W/7.2 W
100 GB
10.2 W/7.2 W
200 GB
9.1 W/7.6 W
400 GB
9.7 W/8.3 W
600 GB
9.48 W/7.2 W
100 GB
10.2 W/7.2 W
200 GB
9.1 W/7.6 W
400 GB
9.7 W/8.3 W
600 GB
3.5
inches
Issue 03 (2014-11-05)
0.38 kg
(0.84 lb)
106
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
9 Hardware Specifications
S2600T
S5500T
S5600T
S5800T
S6800T
Dimensions of
a controller
enclosure
Weight of a
controller
enclosure
l 30.9 kg
(68.12 lb)
with 12
SAS disks
l 30.9 kg
(68.12 lb)
with 12
SAS disks
l 22.98 kg
(50.66 lb)
without
disks
l 29.9 kg
(65.91 lb)
with 24
SAS disks
l 23.9 kg
(52.70 lb)
without
disks
Issue 03 (2014-11-05)
Dimensions of
a 4 U SAS disk
enclosure
Weight of a 4
U SAS disk
enclosure
Dimensions of
a 2 U SAS disk
enclosure
Weight of a 2
U SAS disk
enclosure
Dimensions of
a 4 U SAS
high-density
disk enclosure
107
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
9 Hardware Specifications
Module
S2600T
S5500T
S5600T
Weight of a 4
U SAS highdensity disk
enclosure
S5800T
S6800T
Dimensions of
a data switch
Weight of a
data switch
11 kg (24.2 lb)
Electrical Specifications
Issue 03 (2014-11-05)
Data Block
Componen
t
S2600T
S5500T
S5600T
S5800T
S6800T
Power
consumption
of a
controller
enclosure
l Peak
consumptio
n: 380 W
l Peak
consumptio
n: 539 W
l Operating
consumptio
n: 350 W
l Operating
consumptio
n: 358 W
l Peak
consumpt
ion: 598
W
l Peak
consum
ption:
768 W
l No-load
consumptio
n: 280 W
l No-load
consumptio
n: 288 W
l Operatin
g
consumpt
ion: 328
W
l Operati
ng
consum
ption:
478 W
l Peak
consu
mption
: 830
W
l No-load
consumpt
ion: 318
W
l Noload
consum
ption:
450 W
l Operati
ng
consu
mption
: 492
W
l Noload
consu
mption
: 461
W
108
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Issue 03 (2014-11-05)
9 Hardware Specifications
Data Block
Componen
t
S2600T
S5500T
S5600T
Power
consumption
of a 2 U SAS
disk
enclosure
Power
consumption
of a 4 U SAS
disk
enclosure
Power
consumption
of a 4 U SAS
high-density
disk
enclosure
Power
consumption
of a data
switch
S5800T
S6800T
l Peak consumption: 99 W
l Operating consumption: 87 W
l No-load consumption: 74 W
109
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
9 Hardware Specifications
Data Block
Componen
t
S2600T
S5500T
S5600T
Voltage,
rated current,
rated power
l Controller
enclosure
l Controller
enclosure
l Controller enclosure
100 V to
127 V,
10 A,
650 W
100 V to
127 V,
10 A,
650 W
200 V to
240 V, 5
A, 650
W
200 V to
240 V, 5
A, 650
W
100 V to
127 V, 6
A, 480
W
200 V to
240 V, 3
A, 480
W
l Disk
enclosure
100 V to
127 V, 6
A, 480
W
200 V to
240 V, 3
A, 480
W
l Highdensity disk
enclosure
100 V to
127 V,
10 A,
800 W
(2+2
redunda
ncy)
l Disk
enclosure
100 V to
127 V, 6
A, 480
W
S5800T
S6800T
200 V to
240 V, 3
A, 480
W
l Highdensity disk
enclosure
100 V to
127 V,
10 A,
800 W
(2+2
redunda
ncy)
200 V to
240 V, 5
A, 800
W (2+2
redunda
ncy)
200 V to
240 V, 5
A, 800
W (2+2
Issue 03 (2014-11-05)
110
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Data Block
Componen
t
S2600T
9 Hardware Specifications
S5500T
S5600T
S5800T
S6800T
When the
output power is
170 W, the
BBU provides
power for the
storage system
for 5.5
minutes.
redunda
ncy)
BBU
When the
output power is
100 W, the
BBU provides
power for the
storage system
for 4 minutes.
Reliability Specifications
Issue 03 (2014-11-05)
Item
S2600T
S5500T
System reliability
99.999%
700,000 hours
2 hours
S5600T
S5800T
S6800T
111
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Issue 03 (2014-11-05)
112
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Measures taken after the fault occurs and the related results
113
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Issue 03 (2014-11-05)
114
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
B Glossary
Glossary
A
The module that transfers the external AC power supply into the power
AC power module supply for internal use.
Application
server
Asynchronous
remote
replication
Issue 03 (2014-11-05)
Backup
Bandwidth
Baud rate
The number of times per second the signal can change on a transmission
line. Commonly, the transmission line uses only two signal states,
making the baud rate equal to the number of bits per second that can be
transferred. The underlying transmission technique may use some of the
bandwidth, so it may not be the case that user data transfers at the line's
specified bit rate.
Bit error
The percentage of bits that have errors relative to the total number of
bits received in a transmission.
115
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
B Glossary
Bonding
Boundary scan
Browser/Server
An architecture that defines the roles of browser and server, where the
browser is the service request party and the server is the service provider.
Issue 03 (2014-11-05)
The ratio of directly accessed I/O from Cache to all the I/O operation
during the read operation.
Cache prefetch
strategy
According to the operation in which data has been read or is being read,
the required data is read from a disk into the cache in advance.
Captive Screw
After the screw is loosened, screw caps and bolts are not disconnected
from the main body.
Cascading
CHAP
Clone
Cluster
Coffer
Coffer disk
Command device
A special LUN through which the host can send inband commands to
storage devices.
116
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
B Glossary
Constant prefetch A cache prefetch strategy. The size of the data to be prefetched is the
size as set. This strategy applies to the applications that require reading
data of a fixed size in a certain order. An example is the streaming media
demanded by multiple subscribers who use the same bit rate.
Controller
Controller
enclosure
Copyback
The process of copying the data from the hot spare disk back to the
previous disk when the faulty member disk is restored or replaced by a
new one.
Copying
A state of pair. The state indicates that the source LUN data is being
synchronized to the target LUN.
Issue 03 (2014-11-05)
Data flow
A process that involves processing the data extracted from the source
system, such as filtering, integration, calculation, and summary, finding
and solving data inconsistency, and deleting invalid data so that the
processed data meets the requirements of the destination system for the
input data.
Data migration
It is the process to cleanse and transform history data, and then load
them to the new system.
Data source
A system, database, or file that can make BOs persistent. A data source
can be a database instance or a database user.
Data switch
Dirty data
The data that is stored temporarily on cache and has not been written
onto disks.
Disaster recovery
Disk array
117
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
B Glossary
Disk Domain
Disk location
Locate a hard disk, that is, determine the enclosure number and slot
number of the hard disk in the storage system.
Disk enclosure
Disk utilization
E
eDevLUN
(external device
LUN)
Engine
Expansion
Expander module
Issue 03 (2014-11-05)
Failover
Field replaceable
unit
File Engine
Firmware
Front-end host
port
The port that connects the controller enclosure to the service side and
transfers service data. There are three types of front-end host ports: SAS,
FC, and iSCSI.
118
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
B Glossary
G
Gateway
H
Hard disk
Heartbeat
Hit ratio
Hot swap
Issue 03 (2014-11-05)
I/O
Inband
management
Initiator
119
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
B Glossary
Intelligent
prefetch
Interface module
L
Load balance
Logical unit
The entity is located inside the SCSI object, and can execute I/O
commands. After a SCSI I/O command is sent to an object, the logic
unit inside the object executes this command. Usually, each SCSI
physical disk has one logic unit. A tape drive and array controller may
have multiple logic units, which process different I/O commands. Each
logic unit inside an array controller corresponds to a virtual disk.
Logical unit
number
LUN format
The process of writing 0 bits in the data area on the logical drive and
generating related parity bits so that the logical drive can be in the ready
state.
LUN mapping
The storage system maps LUNs to ASs so that the ASs can access the
storage reorganization.
LUN migration
A method for the data in the LUN to migrate between different physical
storage space while ensuring data integrity and uninterrupted operation
host services.
LUN copy
The function of copying the original LUN data to one or multiple target
LUNs.
Issue 03 (2014-11-05)
Maintenance
terminal
Management
network
120
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Management
network port
B Glossary
N
Node
A managed device in the network. For a device with a single frame, one
node stands for one device. For a device with multiple frames, one node
stands for one frame of the device.
O
Out-of-band
management
A management mode used during out-of-band networking. In the outof-band management mode, the management and control information
of the network and the bearer service information of the user network
are transmitted through different logical channels.
Original LUN
The LUN where the original data of the copied LUNs is located.
Owning
controller
For a LUN, the user configures the owing controller, that is, specified
the created LUN to a certain controller. When the owning controller of
the LUN is invalid, another controller manages the LUN automatically.
When the owning controller of the LUN is restored, the original
controller manages the LUN again.
P
Power failure
protection
When the external power failure occurs, the AC PEM depends on the
battery for power supply, which ensures the integrity of the dirty data
in cache.
Pre-copy
Primary storage
controller
Primary/
Secondary
switchover
Prior controller
For the application server LUN, prior controller means that the working
controller is the owner controller of the corresponding array LUN.
Issue 03 (2014-11-05)
121
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
B Glossary
RAID level
Reconstruction
Redundancy
The scheme to add more than one channels, elements or parts that have
the same functions with the counterparts in the system or device at a
critical place. When a fault occurs, the system or device can work well,
and the reliability is then improved.
Remote
replication
Reverse
synchronizing
The process of restoring data from the redundancy machine (RM) when
the services of the production machine (PM) are recovering.
Route
The path that network traffic takes from its source to its destination. In
a TCP/IP network, each IP packet is routed independently. Routes can
change dynamically.
Issue 03 (2014-11-05)
Script
Secondary
controller
Serial port
Service data
Data which is saved in data disk. Service data is the data source for
computing check data in parity disk.
Service network
port
122
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Issue 03 (2014-11-05)
B Glossary
SFP optical
transceiver
Simple network
management
protocol
Single point
failure
Small computer
system interface
SmartTenancy
Snapshot
Snapshot copy
Storage system
Storage unit
Streaming media
Stripe
123
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
B Glossary
Subnet
Subnet mask
Synchronous
remote
replication
T
Target
Target LUN
Thin provisioning
Thin LUN
The thin LUN is a logic disk that can be accessed by hosts. The thin
LUN dynamically allocates storage resources from the thin pool
according to the actual capacity requirements of users.
Timing Snapshot
Topology
Trap
U
User datagram
protocol
User interface
Issue 03 (2014-11-05)
124
OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
Variable prefetch
B Glossary
vStore
W
Working
controller
The controller used by the array LUN to read and write a disk.
Write back
Write through
Z
Zone
Issue 03 (2014-11-05)
125