You are on page 1of 131

OceanStor

S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
V200R002C20

Hardware Description
Issue

03

Date

2014-11-05

HUAWEI TECHNOLOGIES CO., LTD.

Copyright Huawei Technologies Co., Ltd. 2014. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address:

Huawei Industrial Base


Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website:

http://enterprise.huawei.com

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

About This Document

About This Document

Purpose
This document describes the hardware, device components, cables, environment requirements,
standard compliance and granted certifications of the storage system.

Intended Audience
This document is intended for:
l

Technical support engineers

Maintenance engineers

Content Conventions
The purchased products, services, and features are stipulated by the commercial contract made
between Huawei and the customer. All or partial products, services and features described in
this document may not be within the purchased scope or the usage scope. Unless otherwise
agreed by the contract, all statements, information, and recommendations in this document are
provided "AS IS" without warranties, guarantees, or representations of any kind, either express
or implied.
As part of an effort to improve and enhance the product performance and capabilities, Huawei
periodically releases revisions of the hardware and software. Therefore, some functions
described in this document may not be supported by all versions of the software or hardware
currently in use. For the up-to-date information about product features, refer to the product
release notes.
If a product does not function as described in this document, contact Huawei technical support
engineers.

Change History
Changes between document issues are cumulative. The latest document issue contains all the
changes made in earlier issues.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

ii

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

About This Document

Updates in Issue 03 (2014-11-05)


Third commercial release.
Bug fixed.

Updates in Issue 02 (2014-08-30)


Second commercial release.
Bug fixed.

Issue 01 (2014-05-30)
This is the first official release.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

iii

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Contents

Contents
About This Document.....................................................................................................................ii
1 Device Composition......................................................................................................................1
2 Hardware Introduction.................................................................................................................3
2.1 2 U Controller Enclosure................................................................................................................................................4
2.2 4 U Controller Enclosure................................................................................................................................................8
2.3 2 U SAS Disk Enclosure..............................................................................................................................................11
2.4 4 U SAS Disk Enclosure..............................................................................................................................................13
2.5 File Engine....................................................................................................................................................................15
2.6 Data Switch...................................................................................................................................................................17
2.7 4 U High-Density Disk Enclosure................................................................................................................................18

3 Device Components....................................................................................................................21
3.1 System Enclosure.........................................................................................................................................................23
3.2 Controller......................................................................................................................................................................26
3.3 Fan-BBU Module.........................................................................................................................................................31
3.4 Fan Module...................................................................................................................................................................32
3.5 BBU Module.................................................................................................................................................................36
3.6 Power Module...............................................................................................................................................................37
3.7 I/O Interface Module....................................................................................................................................................41
3.8 Management Module....................................................................................................................................................50
3.9 Expansion Module........................................................................................................................................................51

4 Indicator Introduction................................................................................................................56
4.1 Indicator Description (2 U Controller Enclosure)........................................................................................................57
4.2 Indicator Description (4 U Controller Enclosure)........................................................................................................64
4.3 Indicator Description (2 U SAS Disk Enclosure).........................................................................................................68
4.4 Indicator Description (4 U SAS Disk Enclosure).........................................................................................................70
4.5 Indicator Description (File Engine)..............................................................................................................................73
4.6 Indicator Description (Data Switch).............................................................................................................................76
4.7 Indicator Description (4 U High-Density Disk Enclosure)..........................................................................................78

5 Device Cables...............................................................................................................................82
5.1 Power Cable..................................................................................................................................................................83
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

iv

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Contents

5.2 Ground Cable................................................................................................................................................................83


5.3 Network Cable..............................................................................................................................................................84
5.4 Serial Cable...................................................................................................................................................................84
5.5 Mini SAS Cable............................................................................................................................................................85
5.6 Optical Fiber.................................................................................................................................................................86
5.7 AOC Cable...................................................................................................................................................................87

6 Environment Requirements......................................................................................................89
7 Standard Compliance.................................................................................................................92
8 Certifications................................................................................................................................96
9 Hardware Specifications..........................................................................................................101
A How to Obtain Help.................................................................................................................112
A.1 Preparations For Contacting Huawei.........................................................................................................................113
A.1.1 Collecting Troubleshooting Information................................................................................................................113
A.1.2 Making Debugging Preparations............................................................................................................................113
A.2 How to Use the Document.........................................................................................................................................113
A.3 How to Obtain Help from Website............................................................................................................................113
A.4 Ways to Contact Huawei...........................................................................................................................................114

B Glossary......................................................................................................................................115

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

1 Device Composition

Device Composition

The intelligent storage system consists of a controller enclosure and disk enclosures. The system
presents high reliability, blazing performance, and large capacity.
Different models use different controller enclosures and disk enclosures. Table 1-1 lists the
controller enclosures and disk enclosures used by each model.
Table 1-1 Controller enclosures and disk enclosures used by each model
Product
Model

Controller Enclosure

Disk Enclosure

Data Switch

S2600T

2 U 12-disk controller
enclosure

l 4 U SAS disk enclosure

None

l 4 U High-Density disk
enclosure

S5500T

l 2 U 12-disk
controller enclosure

l 2 U SAS disk enclosure

Data switch (multicontroller)

l 4 U SAS disk enclosure


l 2 U 24-disk
controller enclosure
l 4 U High-Density disk
enclosure

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

1 Device Composition

Product
Model

Controller Enclosure

Disk Enclosure

Data Switch

S5600T/
S5800T/
S6800T

4 U controller enclosure

l 2 U SAS disk enclosure

Data switch (multicontroller)

l 4 U SAS disk enclosure

l 4 U High-Density disk
enclosure

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Hardware Introduction

About This Chapter


The storage system offers flexible controller enclosure and disk enclosure configurations,
allowing on-demand configuration.
2.1 2 U Controller Enclosure
The 2 U controller enclosure adopts a modular design and consists of a system enclosure,
controllers, fan-BBU modules, power modules, disk modules and interface modules.
2.2 4 U Controller Enclosure
The 4 U controller enclosure adopts a modular design and consists of controllers, backup battery
unit (BBU) modules, power modules, fan modules, and interface modules.
2.3 2 U SAS Disk Enclosure
The 2U SAS disk enclosure adopts a modular design and consists of a system enclosure,
expansion modules, disk modules, power modules, and fan modules.
2.4 4 U SAS Disk Enclosure
The 4 U SAS disk enclosure adopts a modular design and consists of a system enclosure,
expansion modules, disk modules, power modules, and fan modules.
2.5 File Engine
The file engine adopts a modular design and consists of a system enclosure, controllers, fan
modules, power modules, and interface modules.
2.6 Data Switch
The data switch adopts a modular design and consists of a system enclosure, AC power modules,
and fan modules.
2.7 4 U High-Density Disk Enclosure
The high-density disk enclosure consists of a system enclosure, fan modules, power modules,
expansion modules, and disk modules.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

2.1 2 U Controller Enclosure


The 2 U controller enclosure adopts a modular design and consists of a system enclosure,
controllers, fan-BBU modules, power modules, disk modules and interface modules.

Overall Structure
Figure 2-1 shows the overall structure of a 2 U 24-disk controller enclosure, Figure 2-2 shows
the overall structure of a 2 U 12-disk controller enclosure (S5500T), and Figure 2-3 shows the
overall structure of the 2 U 12-disk controller enclosure (S2600T).
Figure 2-1 Overall structure of the 2 U 24-disk controller enclosure

System enclosure

Power module

Fan-BBU module

Controller

Disk module

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Figure 2-2 Overall structure of a 2 U 12-disk controller enclosure (S5500T)

System enclosure

Power module

Fan-BBU module

Controller

Disk module

Figure 2-3 Overall structure of a 2 U 12-disk controller enclosure (S2600T)

System enclosure

Power module

Fan-BBU module

Controller

Disk module

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Front View
Figure 2-4 shows the front view of a 2 U 24-disk controller enclosure, Figure 2-5 shows the
front view of a 2 U 12-disk controller enclosure (S5500T), and Figure 2-6 shows the front view
of a 2 U 12-disk controller enclosure (S2600T).
Figure 2-4 Front view of a 2 U 24-disk controller enclosure

System enclosure

Coffer disk label

2.5-inch disk module

NOTE

The disk slots of a 2 U 24-disk controller enclosure are numbered 0 to 23 from left to right. The four coffer
disks are located in slot 0 to slot 3.

Figure 2-5 Front view of a 2 U 12-disk controller enclosure (S5500T)

System enclosure

Coffer disk label

3.5-inch disk module

NOTE

The disk slots of a 2 U 12-disk controller enclosure are numbered 0 to 11 from left to right and from top
to bottom. The four coffer disks are located in slot 0 to slot 3.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Figure 2-6 Front view of a 2 U 12-disk controller enclosure (S2600T)

USB port

System enclosure

3.5-inch disk module

Coffer disk label

Power switch button

NOTE

The disk slots of a 2 U 12-disk controller enclosure are respectively numbered as 0 to 11 from left to right
and from top to bottom. The four coffer disks are located in slot 0 to slot 3.

Rear View
Figure 2-7 shows the rear view of a 2 U controller enclosure (S5500T), and Figure 2-8 shows
the rear view of a 2 U controller enclosure (S2600T).
NOTE

The storage system supports 1 Gbit/s iSCSI interface module, 10 Gbit/s TOE interface module, 10 Gbit/s
FCoE interface module, and 8 Gbit/s Fibre Channel interface module. The preceding figure uses an 8 Gbit/
s Fibre Channel interface module as an example.

Figure 2-7 Rear view of a 2 U controller enclosure (S5500T)

System enclosure

Power module

Fan-BBU module

Controller handle

Management network port

Maintenance network port

Serial port

Interface module handle

8 Gbit/s Fibre Channel port

10

Controller

11

8 Gbit/s Fibre Channel port

12

Fan-BBU module handle

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
13

Power module handle

15

Mini SAS expansion port

2 Hardware Introduction
14

Power module socket

NOTE

The storage system supports 1 Gbit/s iSCSI interface module, 10 Gbit/s TOE interface module, and 8 Gbit/
s Fibre Channel interface module. The preceding figure uses an 8 Gbit/s Fibre Channel interface module
as an example.

Figure 2-8 Rear view of a 2 U controller enclosure (S2600T)

Power module handle

Fan-BBU module handle

Management network port

Maintenance network port

Serial port

Interface module handle

8 Gbit/s Fibre Channel port

Controller

1 Gbit/s iSCSI port

10

Power module socket

11

Mini SAS expansion port

12

Controller handle

13

Fan-BBU module

14

Power module

15

System enclosure

2.2 4 U Controller Enclosure


The 4 U controller enclosure adopts a modular design and consists of controllers, backup battery
unit (BBU) modules, power modules, fan modules, and interface modules.

Overall Structure
Figure 2-9 shows the overall structure of a 4 U controller enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Figure 2-9 Overall structure of a 4 U controller enclosure

System enclosure

Controller

BBU module

Fan module

Power module

Interface module

Front View
Figure 2-10 shows the front view of a 4 U controller enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Figure 2-10 Front view of a 4 U controller enclosure

System enclosure

Controller handle

Controller

Controller Power button

BBU module

BBU module handle

Rear View
Figure 2-11 shows the rear view of the controller enclosure.
Figure 2-11 Rear view of the controller enclosure (S5600T)

System enclosure

Power module handle

Fan module

Fan module handle

Management module handle

Power module

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

10

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Power module socket

1 Gbit/s iSCSI interface module handle

8 Gbit/s Fibre Channel interface module handle

10 10 Gbit/s TOE interface module handle

11 6 Gbit/s SAS expansion module handle

12 Mini SAS expansion port

13 Serial port

14 Maintenance network port

15 Management network port

16 1 Gbit/s iSCSI port

17 8 Gbit/s Fibre Channel port

18 10 Gbit/s TOE port

NOTE

You can configure a controller enclosure with the following types of interface module:
l Management module (mandatory, used for management).
l 6 Gbit/s SAS expansion module (mandatory, used for connecting to disk enclosures).
l 1 Gbit/s iSCSI interface module, 8 Gbit/s Fibre Channel interface module, 10 Gbit/s TOE interface
module, 10 Gbit/s FCoE interface module (optional, choose at least one of the preceding interface
modules, used for connecting to application servers).
l 5 Gbit/s PCIe interface modules (in slots A3 and B3): used for connecting controller enclosure.

2.3 2 U SAS Disk Enclosure


The 2U SAS disk enclosure adopts a modular design and consists of a system enclosure,
expansion modules, disk modules, power modules, and fan modules.

Overall Structure
Figure 2-12 shows the overall structure of a 2 U SAS disk enclosure.
Figure 2-12 Overall structure of a 2 U SAS disk enclosure

Issue 03 (2014-11-05)

System enclosure

Power module

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

11

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3

Fan module

Disk module

2 Hardware Introduction
4

Expansion module

Front View
Figure 2-13 shows the front view of the 2 U SAS disk enclosure.
Figure 2-13 Front view of the disk enclosure

System enclosure

2.5-inch disk module

Rear View
Figure 2-14 shows the rear view of the 2 U SAS disk enclosure.
Figure 2-14 Rear view of the disk enclosure with AC power modules

System enclosure

Power module handle

Fan module handle

Serial port

Mini SAS PRI expansion port

Mini SAS EXP expansion port

ID display of the disk enclosure

Power module

Expansion module

10

Expansion module handle

11

Fan module

12

Power module socket

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

12

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

2.4 4 U SAS Disk Enclosure


The 4 U SAS disk enclosure adopts a modular design and consists of a system enclosure,
expansion modules, disk modules, power modules, and fan modules.

Structure
Figure 2-15 shows the overall structure of a 4 U SAS disk enclosure.
Figure 2-15 Overall structure of a 4 U SAS disk enclosure

System enclosure

AC power module

Fan module

Expansion module

Disk module

Front View
Figure 2-16 shows the front view of the 4 U SAS disk enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

13

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Figure 2-16 Front view of a 4 U SAS disk enclosure

System enclosure

3.5-inch disk module

Rear View
Figure 2-17 shows the rear view of a 4 U SAS disk enclosure.
Figure 2-17 Rear view of a 4 U SAS disk enclosure

System enclosure

Power module handle

Fan module handle

Expansion module

ID display of the disk enclosure

Mini SAS EXP expansion port

Mini SAS PRI expansion port

Serial port

Expansion module handle

10

Fan module

11

Power module

12

Power module socket

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

14

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

2.5 File Engine


The file engine adopts a modular design and consists of a system enclosure, controllers, fan
modules, power modules, and interface modules.

Overall Structure
Figure 2-18 shows the overall structure of the file engine.
Figure 2-18 Overall structure of the file engine configured with AC power modules

System enclosure

Controller

Fan module

Power module

Interface module

Front View
Figure 2-19 shows the front view of the file engine.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

15

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Figure 2-19 Front view of the file engine

System enclosure

Controller handle

Controller

Power button

Filler panel

Rear View
Figure 2-20 shows the rear view of the file engine.
Figure 2-20 Rear view of the file engine

System enclosure

Power module handle

Fan module handle

Fan module

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

16

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Management network port

Power module

Power module socket

1 Gbit/s iSCSI port

1 Gbit/s iSCSI interface module handle

10 8 Gbit/s Fibre Channel port

11 Maintenance network port

12 Serial port

13 8 Gbit/s Fibre Channel interface module handle

2.6 Data Switch


The data switch adopts a modular design and consists of a system enclosure, AC power modules,
and fan modules.

Structure
Figure 2-21 shows the overall structure of a data switch.
Figure 2-21 Overall structure of a data switch

System enclosure

Fan module

AC power module

Front View
Figure 2-22 shows the front view of data switch.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

17

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Figure 2-22 Front view of data switch

AC power module handle

AC power module latch

AC power module

Fan module handle

Fan module latch

Fan module

Rear View
Figure 2-23 shows the rear view of a data switch.
Figure 2-23 Rear view of a data switch

Power socket

Management network port 0

PCIe port

Management network port 1

Serial port

2.7 4 U High-Density Disk Enclosure


The high-density disk enclosure consists of a system enclosure, fan modules, power modules,
expansion modules, and disk modules.

Overall Structure
Figure 2-24 shows the overall structure of a high-density disk enclosure.
NOTE

The high-density disk enclosure is configured four 800 W power modules, the voltage input scope is from
100 V to 127 V and from 200 V to 240 V.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

18

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Figure 2-24 Overall structure of a high-density disk enclosure with four 800 W power modules

System enclosure

Power module

Fan module

Expansion module

Disk module

Front View
Figure 2-25 shows the front view of a high-density disk enclosure.
Figure 2-25 Front view of a high-density disk enclosure

ID display of the disk enclosure

Captive screw

Handle

Rear View
Figure 2-26 shows the rear view of a high-density disk enclosure with four 800 W power
modules.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

19

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

2 Hardware Introduction

Figure 2-26 Rear view of a high-density disk enclosure with four 800 W power modules

Power module handle

Power module

Power module socket

Power module latch

Fan module

Fan module handle

Fan module latch

Mini SAS PRI HD expansion port

Expansion module

10

ID display of the disk enclosure

11

Expansion module handle

12

Mini SAS EXP HD expansion port

13

Expansion module latch

14

Serial port

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

20

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Device Components

About This Chapter


This section provides details about components of devices and their indicators.
3.1 System Enclosure
The system enclosure integrates a midplane in order to provide reliable connections for interface
modules and to distribute power and signals to inner modules.
3.2 Controller
A controller is a core component of the storage system. It is responsible for processing storage
services, receiving configuration and management commands from users, and saving the
configuration information, managing disks, and storing critical data onto the coffer disks.
3.3 Fan-BBU Module
The fan-BBU module is hot-swappable. It contains the fan module and BBU module, and it can
realize the system heat dissipation and backup power supply. The fans support intelligent speed
control. The controller determines and adjusts the rotational speed of the fans according to the
temperature of the system.
3.4 Fan Module
The fan modules are hot-swappable. The intelligent speed control function enables the fan
module to intelligently adjust the fan speed according to system temperature.
3.5 BBU Module
BBU modules provide backup power when the external power supply of the system fails to
ensure the integrity of the service data on the storage array.
3.6 Power Module
The storage system supports AC power modules. The power modules can ensure that the storage
system works correctly in maximum power consumption mode.
3.7 I/O Interface Module
I/O interface modules connect storage devices to application servers. The storage device supports
8 Gbit/s Fibre Channel, 16 Gbit/s Fibre Channel, 1 Gbit/s iSCSI, 10 Gbit/s TCP offload engine
(TOE), and 10 Gbit/s Fibre Channel over Ethernet (FCoE), 5 Gbit/s PCIe interface modules.
3.8 Management Module
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

21

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

A management module provides a management network port, a maintenance network port, and
a serial port. The management module saves system configuration data, alarm data, and log data
onto solid-state drive (SSD) coffer disks.
3.9 Expansion Module
An expansion module provides expansion ports that are used for communication between a
controller enclosure and a disk enclosure. The module transfers data between a controller
enclosure and a disk enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

22

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

3.1 System Enclosure


The system enclosure integrates a midplane in order to provide reliable connections for interface
modules and to distribute power and signals to inner modules.

System Enclosure of a 4 U Controller Enclosure and File Engine


Figure 3-1 shows a system enclosure of a 4 U controller enclosure and file engine.
Figure 3-1 System enclosure of a 4 U controller enclosure and file engine

System Enclosure of a 2 U Controller Enclosure


Figure 3-2 shows a system enclosure of a 2 U controller enclosure (S2600T), and Figure 3-3
shows a system enclosure of a 2 U controller enclosure (S5500T).

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

23

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-2 System enclosure of a 2 U controller enclosure (S2600T)

Figure 3-3 System enclosure of a 2 U controller enclosure (S5500T)

System Enclosure of a 2 U Disk Enclosure


Figure 3-4 shows a system enclosure of a 2 U disk enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

24

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-4 System enclosure of a 2 U disk enclosure

System Enclosure of a 4 U Disk Enclosure


Figure 3-5 shows a system enclosure of a 4 U disk enclosure.
Figure 3-5 System enclosure of a 4 U disk enclosure

System Enclosure of High-Density Disk Enclosure


Figure 3-6 shows a system enclosure of a high-density disk enclosure.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

25

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-6 System enclosure of a high-density disk enclosure

System Enclosure of a Data Switch


Figure 3-7 shows a system enclosure of a data switch.
Figure 3-7 System enclosure of a data switch

3.2 Controller
A controller is a core component of the storage system. It is responsible for processing storage
services, receiving configuration and management commands from users, and saving the
configuration information, managing disks, and storing critical data onto the coffer disks.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

26

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Controller of a 4 U Controller Enclosure and File Engine


Figure 3-8 shows a controller of a 4 U controller enclosure and file engine.
Figure 3-8 Controller of a 4 U controller enclosure and file engine

Controller handle

Controller Power indicator

Controller Alarm indicator

Controller Power button

Table 3-1 lists the states and corresponding meanings of indicators on a controller of a 4 U
controller enclosure after the controller enclosure is powered on.
Table 3-1 Checklist for indicators on a controller of a 4 U controller enclosure
No.

Indicator Name

Status and Description

Controller Power
indicator

l Steady green: The controller is powered on


correctly.
l Blinking green: The system is being powered
on or powered off.
l Off: The controller is powered off.

Controller Alarm
indicator

l Steady red: An alarm is generated on the


controller.
l Off: The controller runs properly.

Controller of a 2 U Controller Enclosure (S2600T)


Figure 3-9 shows a controller of a 2 U controller enclosure (S2600T).

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

27

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-9 Controller of 2 U controller enclosure (S2600T)

1 Controller handle

2 Link/Active indicator of the management network port

3 Management network port

4 Speed indicator of the management network port

5 Maintenance network port

6 Serial port

7 Interface module handle

8 8 Gbit/s Fibre Channel port

9 1 Gbit/s iSCSI port

10 Link/Active indicator of the 1 Gbit/s iSCSI port

11 Speed indicator of the 1 Gbit/s iSCSI port

12 Link/Speed indicator of the 8 Gbit/s Fibre Channel port

13 Controller Alarm indicator

14 Controller Power indicator

15 Power indicator of the module

16 Mini SAS expansion port

17 Indicator of the mini SAS expansion port

Table 3-2 lists the states and corresponding meanings of indicators on a controller of a 2 U
controller enclosure (S2600T) after the controller enclosure is powered on.
Table 3-2 Checklist for the indicators on the rear panel of a controller enclosure (S2600T)
No.

Indicator

Status and Description

Link/Active indicator of
the management network
port

l Steady green: The link to the server is normal.

Speed indicator of the


management network port

l Steady orange: The data transfer rate of the


management network port is 1 Gbit/s.

l Blinking green: Data transfer is in progress.


l Off: The link to the application server is down
or no link exists.

l Off: The data transfer rate of the management


network port is less than 1 Gbit/s.
10

Link/Active indicator of
the 1 Gbit/s iSCSI port

l Steady green: The link to the server is normal.


l Blinking green: Data transfer is in progress.
l Off: The link to the application server is down
or no link exists.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

28

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

No.

Indicator

Status and Description

11

Speed indicator of the 1


Gbit/s iSCSI port

l Steady orange: The data transfer rate between


the iSCSI port and the application server is 1
Gbit/s.
l Off: The data transfer rate between the iSCSI
port and the application server is less than 1
Gbit/s.

12

Link/Speed indicator of an
8 Gbit/s Fibre Channel
port

l Steady blue: Data is transferred between the


controller enclosure and the application server
at a rate of 8 Gbit/s.
l Blinking blue: Data is being transferred.
l Steady green: Data is transferred between the
controller enclosure and the application server
at a rate of 4 Gbit/s or 2 Gbit/s.
l Blinking green: Data is being transferred.
l Steady red: The port is faulty.
l Off: The link is down.

13

Controller Alarm
indicator

l Steady red: An alarm is generated on the


controller.
l Off: The controller is working properly.

14

Controller Power
indicator

l Steady green: The controller is powered on.


l Blinking green: The system is being powered
on or powered off.
l Off: The controller is powered off.

15

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

17

Indicator of a mini SAS


expansion port

l Steady blue: Data is transferred between the


controller enclosure and the disk enclosure at a
rate of 4 x 6 Gbit/s.
l Steady green: Data is transferred between the
controller enclosure and the disk enclosure at a
rate of 4 x 3 Gbit/s.
l Steady red: The port is faulty.
l Off: The link is down.

Controller of a 2 U Controller Enclosure (S5500T)


Figure 3-10 shows a controller of a 2 U controller enclosure (S5500T).
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

29

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-10 Controller of a 2 U controller enclosure (S5500T)

1 Link indicator of the management network port

2 Management network port

3 Active indicator of the management network port 4 Maintenance network port


5 Serial port

6 Interface module handle

7 8 Gbit/s Fibre Channel port

8 8 Gbit/s Fibre Channel port

9 Controller Power button

10 Link/Speed indicator of the 8 Gbit/s Fibre Channel


port

11 Controller Alarm indicator

12 Controller Power indicator

13 Power indicator of the module

14 Mini SAS expansion port

15 Indicator of the mini SAS expansion port

16 Controller handle

Table 3-3 lists the states and corresponding meanings of indicators on a controller of a 2 U
controller enclosure (S5500T) after the controller enclosure is powered on.
Table 3-3 Checklist for indicators on a controller of a 2 U controller enclosure (S5500T)
No.

Indicator Name

Status and Description

Link indicator of the


management network
port

l Steady green: The link of the management network


port is up.

Active indicator of the


management network
port

l Blinking orange: Data transfer is in progress.

Link/Speed indicator
of the 8 Gbit/s Fibre
Channel port

l Steady blue: The data transfer rate between the


storage system and the application server is 8 Gbit/
s.

10

l Off: The link of the management network port is


down.

l Off: No data transfer is in progress.

l Blinking blue: Data transfer is in progress.


l Steady green: The data transfer rate between the
storage system and the application server is 4 Gbit/
s or 2 Gbit/s.
l Blinking green: Data transfer is in progress.
l Steady red: The port is faulty.
l Off: The link of the port is down.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

30

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

No.

Indicator Name

Status and Description

11

Controller Alarm
indicator

l Steady red: An alarm is generated on the


controller.
l Off: The controller runs properly.

12

Controller Power
indicator

l Steady green: The controller is powered on


correctly.
l Blinking green: The system is being powered on
or powered off.
l Off: The controller is powered off.

13

Module Power
indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request to
the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

15

Indicator of the mini


SAS expansion port

l Steady blue: The data transfer rate between the


mini SAS expansion port and the expansion
enclosure is 4 x 6 Gbit/s.
l Steady green: The data transfer rate between the
mini SAS expansion port and the expansion
enclosure is 4 x 3 Gbit/s.
l Steady red: The port is faulty.
l Off: The link of the port is down.

3.3 Fan-BBU Module


The fan-BBU module is hot-swappable. It contains the fan module and BBU module, and it can
realize the system heat dissipation and backup power supply. The fans support intelligent speed
control. The controller determines and adjusts the rotational speed of the fans according to the
temperature of the system.
Figure 3-11 shows a fan-BBU module.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

31

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-11 Fan-BBU module

1 Handle of fan-BBU module

2 Fan-BBU module Running/Alarm indicator

Table 3-4 lists the states and corresponding meanings of the fan-BBU indicator after it is
powered on.
Table 3-4 Checklist for the fan-BBU module indicator
No.

Indicator Name

Status and Description

Fan-BBU Running/
Alarm indicator

l Steady green: The BBU is charged full and the


fan is working properly.
l Blinking green: The BBU is being charged.
l Blinking amber: The BBU is discharging.
l Steady red: The fan or BBU is faulty.

3.4 Fan Module


The fan modules are hot-swappable. The intelligent speed control function enables the fan
module to intelligently adjust the fan speed according to system temperature.

Fan module of a 4 U Controller Enclosure and File Engine


Figure 3-12 shows a fan module of a 4 U controller enclosure and file engine.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

32

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-12 Fan module of a 4 U controller enclosure and file engine

1 Fan module Running/Alarm indicator

2 Fan module handle

Table 3-5 lists the states and corresponding meanings of the fan module indicator after it is
powered on.
Table 3-5 Checklist for the fan module indicator
No.

Indicator Name

Status and Description

Fan module Running/


Alarm indicator

l Steady green: The fan module is working


properly.
l Steady red: The fan module is faulty.
l Off: Fan module is powered off.

Fan Module of Disk Enclosure


Figure 3-13 shows a fan module of disk enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

33

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-13 Fan module of disk enclosure

1 Fan module handle

2 Fan module Running/Alarm indicator

Table 3-6 lists the states and corresponding meanings of the fan module indicator after it is
powered on.
Table 3-6 Checklist for the fan module indicator
No.

Indicator Name

Status and Description

Fan module Running/


Alarm indicator

l Steady green: The fan module is working


properly.
l Steady red: The fan module is faulty.
l Off: Fan module is powered off.

Fan Module of a High-Density Disk Enclosure


Figure 3-14 shows a fan module of a high-density disk enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

34

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-14 Fan module of a high-density disk enclosure

Fan module handle

Fan module Running/Alarm indicator

Fan module latch

Table 3-7 lists the states and corresponding meanings of the fan module indicator after it is
powered on.
Table 3-7 Checklist for the fan module indicator
No.

Indicator Name

Status and Description

Fan module Running/


Alarm indicator

l Steady green: The fan module is working


properly.
l Steady red: The fan module is faulty.
l Off: Fan module is powered off.

Fan Module of Data Switch


Figure 3-15 shows a fan module of data switch.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

35

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-15 Fan module of data switch

Fan module Running/Alarm indicator

Fan module handle

Fan module latch

Table 3-8 lists the states and corresponding meanings of the fan module indicator after it is
powered on.
Table 3-8 Checklist for the fan module indicator
No.

Indicator Name

Status and Description

Fan module Running/


Alarm indicator

l Steady green: The fan module is working


properly.
l Steady red: The fan module is faulty.
l Off: Fan module is powered off.

3.5 BBU Module


BBU modules provide backup power when the external power supply of the system fails to
ensure the integrity of the service data on the storage array.
Each controller is configured with two BBU modules. Figure 3-16 shows a BBU module.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

36

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-16 BBU module

1 BBU module handle

2 BBU module Running/Alarm indicator

Table 3-9 lists the states and corresponding meanings of the BBU module indicator after it is
powered on.
Table 3-9 Checklist for the BBU module indicator
No.

Indicator Name

Status and Description

BBU Running/Alarm
indicator

l Steady green: The BBU module is charged full.


l Blinking green: The BBU module is being
charged.
l Steady amber: A warning alarm is generated.
You are advised to replace the BBU.
l Blinking amber: The BBU module is
discharging.
l Steady red: The BBU module is faulty.

3.6 Power Module


The storage system supports AC power modules. The power modules can ensure that the storage
system works correctly in maximum power consumption mode.

Power Module for a Disk Enclosure and a 4 U Controller and File Engine
Figure 3-17 shows an AC power module of a 4 U controller enclosure and file engine and disk
enclosure.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

37

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-17 AC power module of a 4 U controller enclosure and file engine and disk enclosure

1 Power module latch

2 Power module handle

3 Power module built-in fan

4 Power module socket

5 Power module Running/Alarm indicator

Table 3-10 lists the states and corresponding meanings of indicators on a power module for a
disk enclosure or 4 U controller enclosure after it is powered on.
Table 3-10 Checklist for indicators on a power module for a disk enclosure or 4 U controller
enclosure
No.

Indicator Name

Status and Description

Power module Running/


Alarm indicator

l Steady green: The power module is working


properly.
l Blinking green: The power module is working
properly and the device is powered off.
l Steady red: The power module is faulty.
l Blinking red: Input undervoltage or
overvoltage.
l Off: No input of external power supply.

Power Module of a 2 U Controller Enclosure


Figure 3-18 shows an AC power module of a 2 U controller enclosure.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

38

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-18 AC power module of a 2 U controller enclosure

1 Power module latch

2 Power module handle

3 Power module built-in fan

4 Power module socket

5 Power module Running/Alarm indicator

Table 3-11 lists the states and corresponding meanings of indicators on a power module for a
disk enclosure or 4 U controller enclosure after it is powered on.
Table 3-11 Checklist for indicators on a power module for a disk enclosure or 4 U controller
enclosure
No.

Indicator Name

Status and Description

Power module Running/


Alarm indicator

l Steady green: The power module is working


properly.
l Blinking green: The power module is working
properly and the device is powered off.
l Steady red: The power module is faulty.
l Blinking red: Input undervoltage or
overvoltage.
l Off: No input of external power supply.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

39

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

AC Power Module of a Data Switch


Figure 3-19 shows an AC power module of a data switch.
Figure 3-19 AC Power module of a data switch

1 AC Power module Running/Alarm indicator

2 AC Power module latch

3 AC Power module handle

Table 3-12 lists the states and corresponding meanings of indicators on a power module for a
data switch after it is powered on.
Table 3-12 Checklist for indicators on a power module for a data switch
No.

Indicator

Status and Description

AC power module Running/Alarm


indicator

l Steady green: The power module is


working properly.
l Steady red: The power module is faulty.
l Off: The power module is powered off.

Power Module of a High-Density Disk Enclosure


Figure 3-20 shows an AC power module of a high-density disk enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

40

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-20 AC power module of a high-density disk enclosure

1 Fan of the power module

2 Power module Running indicator

3 Power module socket

4 Power module latch

5 Power module handle

Table 3-13 lists the states and corresponding meanings of indicators on a power module for a
high-density disk enclosure after it is powered on.
Table 3-13 Checklist for indicators on a power module for a high-density disk enclosure
No.

Indicator

Status and Description

Power module Running indicator

l Steady green: The power module is


running correctly.
l Off: The power module is not power on
or undervoltage, overvoltage,
overtemperature, or short-circuit occurs.

3.7 I/O Interface Module


I/O interface modules connect storage devices to application servers. The storage device supports
8 Gbit/s Fibre Channel, 16 Gbit/s Fibre Channel, 1 Gbit/s iSCSI, 10 Gbit/s TCP offload engine
(TOE), and 10 Gbit/s Fibre Channel over Ethernet (FCoE), 5 Gbit/s PCIe interface modules.

8 Gbit/s Fibre Channel Interface Module


The 8 Gbit/s Fibre Channel interface module provides four 8 Gbit/s Fibre Channel ports for the
storage device to connect to application servers and to receive read/write requests from the
application servers. When the data transfer rate of a device connected to the port is less than the
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

41

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

port rate and the port mode is set to autonegotiation, the port automatically adjusts its rate to
ensure the connectivity of the data transfer channel and the consistency of the data transfer rate.
Figure 3-21 shows an 8 Gbit/s Fibre Channel interface module.
Figure 3-21 8 Gbit/s Fibre Channel interface module

1 Module Power indicator

2 8 Gbit/s Fibre Channel port

3 Link/Speed indicator of an 8 Gbit/s Fibre Channel port

4 Module handle

Table 3-14 lists the states and corresponding meanings of indicators on an 8 Gbit/s Fibre Channel
interface module after it is powered on.
Table 3-14 Checklist for indicators on an 8 Gbit/s Fibre Channel interface module
No.

Indicator Name

Status and Description

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

42

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

No.

Indicator Name

Status and Description

Link/Speed indicator of an
8 Gbit/s Fibre Channel
port

l Steady blue: The data transfer rate between the


storage system and the application server is 8
Gbit/s.
l Blinking blue: Data transfer is in progress.
l Steady green: The data transfer rate between
the storage system and the application server is
4 Gbit/s or 2 Gbit/s.
l Blinking green: Data transfer is in progress.
l Steady red: The port is faulty.
l Off: The link of the port is down.

16 Gbit/s Fibre Channel Interface Module


The 16 Gbit/s Fibre Channel interface module provides two 16 Gbit/s Fibre Channel ports for
the storage device to connect to application servers and to receive read/write requests from the
application servers. When the data transfer rate of a device connected to the port is less than the
port rate and the port mode is set to autonegotiation, the port automatically adjusts its rate to
ensure the connectivity of the data transfer channel and the consistency of the data transfer rate.
Figure 3-22 shows a 16 Gbit/s Fibre Channel interface module.
Figure 3-22 16 Gbit/s Fibre Channel interface module

1 Module Power indicator

2 16 Gbit/s Fibre Channel port

3 Link/Speed indicator of a 16 Gbit/s Fibre Channel port

4 Module handle

Table 3-15 lists the states and corresponding meanings of indicators on a 16 Gbit/s Fibre Channel
interface module after it is powered on.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

43

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Table 3-15 Checklist for indicators on a 16 Gbit/s Fibre Channel interface module
No.

Indicator Name

Status and Description

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

Link/Speed indicator of a
16 Gbit/s Fibre Channel
port

l Steady blue: The data transfer rate between the


storage system and the application server is 16
Gbit/s.
l Blinking blue: Data transfer is in progress.
l Steady green: The data transfer rate between
the storage system and the application server is
8 Gbit/s or 4 Gbit/s.
l Blinking green: Data transfer is in progress.
l Steady red: The port is faulty.
l Off: The link of the port is down.

1 Gbit/s iSCSI Interface Module


A 1 Gbit/s iSCSI interface module provides four 1 Gbit/s iSCSI ports for the storage device to
connect to application servers and to receive read/write requests from the application servers.
Figure 3-23 shows a 1 Gbit/s iSCSI interface module.
Figure 3-23 1 Gbit/s iSCSI interface module

1 Module Power indicator

Issue 03 (2014-11-05)

2 1 Gbit/s iSCSI port

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

44

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description
3 Link/Active indicator of a 1 Gbit/s iSCSI port

3 Device Components
4 Speed indicator of a 1 Gbit/s iSCSI port

5 Module handle

Table 3-16 lists the states and corresponding meanings of indicators on a 1 Gbit/s iSCSI interface
module after it is powered on.
Table 3-16 Checklist for indicators on a 1 Gbit/s iSCSI interface module
No.

Indicator Name

Status and Description

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

Link/Active indicator of a
1 Gbit/s iSCSI port

l Steady green: The link to the server is normal.


l Blinking green: Data transfer is in progress.
l Off: The link to the application server is down
or no link exists.

Speed indicator of a 1
Gbit/s iSCSI port

l Steady orange: The data transfer rate between


the iSCSI port and the application server is 1
Gbit/s.
l Off: The data transfer rate between the iSCSI
port and the application server is less than 1
Gbit/s.

10 Gbit/s TOE Interface Module


A 10 Gbit/s TOE interface module provides four 10 Gbit/s TOE ports for the storage device to
connect to application servers and to receive read/write requests from the application servers.
Figure 3-24 shows a 10 Gbit/s TOE interface module.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

45

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-24 10 Gbit/s TOE interface module

1 Module Power indicator

2 10 Gbit/s TOE port

3 Link/Speed indicator of a 10 Gbit/s TOE port

4 Module handle

Table 3-17 lists the states and corresponding meanings of indicators on a 10 Gbit/s TOE interface
module after it is powered on.
Table 3-17 Checklist for indicators on a 10 Gbit/s TOE interface module
No.

Indicator Name

Status and Description

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

Link/Speed indicator of a
10 Gbit/s TOE port

l Steady blue: The data transfer rate between the


storage system and the application server is 10
Gbit/s.
l Blinking blue: Data transfer is in progress.
l Steady red: The port is faulty.
l Off: The link of the port is down.

10 Gbit/s FCoE Interface Module (Four Ports)


A 10 Gbit/s FCoE interface module provides four 10 Gbit/s FCoE ports for the storage device
to connect to application servers and to receive read/write requests from the application servers.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

46

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-25 shows a 10 Gbit/s FCoE interface module.


Figure 3-25 10 Gbit/s FCoE interface module (Four Ports)

1 Module Power indicator

2 10 Gbit/s FCoE port

3 Link/Speed indicator of a 10 Gbit/s FCoE port

4 Module handle

Table 3-18 lists the states and corresponding meanings of indicators on a 10 Gbit/s FCoE
interface module after it is powered on.
Table 3-18 Checklist for indicators on a 10 Gbit/s FCoE interface module
No.

Indicator Name

Status and Description

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

Link/Speed indicator of a
10 Gbit/s FCoE port

l Steady blue: The data transfer rate between the


storage system and the application server is 10
Gbit/s.
l Blinking blue: Data transfer is in progress.
l Steady red: The port is faulty.
l Off: The link of the port is down.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

47

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

10 Gbit/s FCoE Interface Module (Two Ports)


A 10 Gbit/s FCoE interface module provides two 10 Gbit/s FCoE ports. These ports are service
ports used to connect a storage system to application servers and receive data read/write requests
from application servers.
Figure 3-26 shows a 10 Gbit/s FCoE interface module.
Figure 3-26 10 Gbit/s FCoE interface module (Two Ports)

1 Module Power indicator

2 10 Gbit/s FCoE port

3 Link/Speed indicator of a 10 Gbit/s FCoE port

4 Module handle

Table 3-19 lists the states and corresponding meanings of indicators on a 10 Gbit/s FCoE
interface module after it is powered on.
Table 3-19 Checklist for indicators on a 10 Gbit/s FCoE interface module
No.

Indicator Name

Status and Description

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

Link/Speed indicator of a
10 Gbit/s FCoE port

l Steady blue: The data transfer rate between the


storage system and the application server is 10
Gbit/s.
l Blinking blue: Data transfer is in progress.
l Steady red: The port is faulty.
l Off: The link of the port is down.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

48

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

5 Gbit/s PCIe Interface Module


A 5 Gbit/s PCIe interface module provides two 5 Gbit/s PCIe ports for the storage device
(S5600T) in four-node configuration to connect its belonging controller enclosure to the data
switch and to exchange control flow and data flow among controller enclosures.
Figure 3-27 shows 5 Gbit/s PCIe interface module.
Figure 3-27 5 Gbit/s PCIe interface module

1 Module Power indicator

2 5 Gbit/s PCIe port

3 Link/Speed indicator of a 5 Gbit/s PCIe port

4 Module handle

Table 3-20 lists the states and corresponding meanings of indicators on a 5 Gbit/s PCIe interface
module after it is powered on.
Table 3-20 Checklist for indicators on a 5 Gbit/s PCIe interface module
No.

Indicator Name

Status and Description

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The interface module is faulty.
l Off: The module is powered off.

Link/Speed indicator of a
5 Gbit/s PCIe port

l Steady blue: The data transfer rate between the


PCIe port and the data switch is 5 Gbit/s.
l Steady green: The data transfer rate between the
PCIe port and the data switch is 2.5 Gbit/s.
l Steady red: The port is faulty.
l Off: The link of the port is down.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

49

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

3.8 Management Module


A management module provides a management network port, a maintenance network port, and
a serial port. The management module saves system configuration data, alarm data, and log data
onto solid-state drive (SSD) coffer disks.
Figure 3-28 shows a management module.
Figure 3-28 Management module

1 Module Power indicator

2 Active indicator of the management network port

3 Link indicator of the management network port

4 Serial port

5 Maintenance network port

6 Management network port

7 Module handle

Table 3-21 lists states and corresponding meanings of indicators on the management module
after it is powered on.
Table 3-21 Checklist for management module indicators
No.

Indicator Name

Status and Description

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

Issue 03 (2014-11-05)

Active indicator of the


management network port

l Blinking orange: Data transfer is in progress.


l Off: No data transfer is in progress.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

50

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

No.

Indicator Name

Status and Description

Link indicator of the


management network port

l Steady green: The link of the management


network port is up.
l Off: The link of the management network port
is down.

3.9 Expansion Module


An expansion module provides expansion ports that are used for communication between a
controller enclosure and a disk enclosure. The module transfers data between a controller
enclosure and a disk enclosure.

6 Gbit/s SAS Expansion Module of a 4 U Controller Enclosure


A SAS interface module provides two 4 x 6 Gbit/s mini SAS ports that provides connectivity to
disk enclosures. The SAS interface module connects to the back-end storage array of the storage
system through a mini SAS cable and provides 4 x 6 Gbit/s mini SAS ports for controllers. When
the transfer rate of the connected device is less than that of the expansion port, the expansion
port automatically adjusts the transfer rate to that of the connected device to ensure the
connectivity of the data transfer channel.
Figure 3-29 shows a 6 Gbit/s SAS expansion module.
Figure 3-29 6 Gbit/s SAS expansion module

1 Module Power indicator

2 Mini SAS expansion port

3 Indicator of a mini SAS expansion port

4 Module handle

Table 3-22 lists the states and corresponding meanings of indicators on a 6 Gbit/s SAS expansion
module after it is powered on.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

51

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Table 3-22 Checklist for indicators on a 6 Gbit/s SAS expansion module


No.

Indicator Name

Status and Description

Module Power indicator

l Steady green: The interface module is working


properly.
l Blinking green: There is a hot swapping request
to the module.
l Steady red: The module is faulty.
l Off: The module is powered off.

Indicator of the mini SAS


expansion port

l Steady blue: The data transfer rate between the


mini SAS expansion port and the expansion
enclosure is 4 x 6 Gbit/s.
l Steady green: The data transfer rate between
the mini SAS expansion port and the expansion
enclosure is 4 x 3 Gbit/s.
l Steady red: The port is faulty.
l Off: The link of the port is down.

Expansion Module of a Disk Enclosure


The expansion module provides expansion ports for communication between the disk enclosure
and the controller enclosure. Each expansion module provides a PRI expansion port and an EXP
expansion port.
Figure 3-30 shows an expansion module.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

52

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Figure 3-30 Expansion module

1 ID display of the disk enclosure

2 Mini SAS EXP expansion port

3 Mini SAS PRI expansion port

4 Indicator of a mini SAS expansion port

5 Serial port

6 Expansion module Alarm indicator

7 Expansion module Power indicator

8 Expansion module handle

Table 3-23 lists the states and corresponding meanings of indicators on an expansion module
for a disk enclosure.
Table 3-23 Checklist for indicators on an expansion module for a disk enclosure
No.

Indicator Name

Status and Description

Indicator of the mini SAS


expansion port

l Steady green: The link of the expansion port is


normal at the rate of 4 x 3 Gbit/s.
l Steady blue: The link of the expansion port is
normal at the rate of 4 x 6 Gbit/s.
l Steady red: The port is faulty.
l Off: The link of the expansion port is down.

Expansion module Alarm


indicator

l Steady red: The expansion module is faulty.

Expansion module Power


indicator

l Steady green: The expansion module is


powered on correctly.

l Off: The expansion module is working


properly.

l Off: The expansion module is not powered on.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

53

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Expansion Module of a High-Density Disk Enclosure


The expansion module provides expansion ports for communication between the high-density
disk enclosure and the controller enclosure or between the high-density disk enclosure and the
high-density disk enclosure. Each expansion module provides a PRI HD expansion port and an
EXP HD expansion port.
Figure 3-31 shows an expansion module.
Figure 3-31 Expansion module

1 ID display of the disk enclosure

2 Mini SAS EXP HD expansion port

3 Expansion module handle

4 Expansion module latch

5 Mini SAS PRI HD expansion port

6 Indicator of a mini SAS HD expansion port

7 Serial port

8 Expansion module Alarm indicator

9 Expansion module Power indicator

Table 3-24 lists the states and corresponding meanings of indicators on an expansion module
for a high-density disk enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

54

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

3 Device Components

Table 3-24 Checklist for indicators on an expansion module for a high-density disk enclosure
No.

Indicator Name

Status and Description

Indicator of a mini SAS


HD expansion port

l Steady green: The link of the expansion port is


normal at the rate of 4 x 3 Gbit/s.
l Steady blue: The link of the expansion port is
normal at the rate of 4 x 6 Gbit/s.
l Steady red: The port is faulty.
l Off: The link of the expansion port is down.

Expansion module Alarm


indicator

l Steady red: The expansion module is faulty.


l Blinking red and Running indicator of the
expansion module blinking green: The
expansion module is being located.
l Off: The expansion module is not powered or
is running correctly.

Expansion module Power


indicator

l Steady green: The expansion module is running


correctly.
l Blinking green and Running indicator of the
expansion module blinking red: The expansion
module is being located.
l Off: The expansion module is not powered on.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

55

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Indicator Introduction

About This Chapter


Indicators help users to preliminarily judge whether the device is working properly.
4.1 Indicator Description (2 U Controller Enclosure)
After a controller enclosure is powered on, you can learn about the operating status of the
controller enclosure by observing the indicators on it.
4.2 Indicator Description (4 U Controller Enclosure)
After a controller enclosure is powered on, you can learn about the operating status of the
controller enclosure by observing the indicators on it.
4.3 Indicator Description (2 U SAS Disk Enclosure)
After a disk enclosure is powered on, you can learn about the operating status of the disk
enclosure by observing the indicators on it.
4.4 Indicator Description (4 U SAS Disk Enclosure)
After a disk enclosure is powered on, you can learn about the operating status of the disk
enclosure by observing the indicators on it.
4.5 Indicator Description (File Engine)
After a file engine is powered on, you can learn about the operating status of the file engine is
working properly.
4.6 Indicator Description (Data Switch)
After a data switch is powered on, you can learn about the operating status of the data switch by
observing the indicators on it.
4.7 Indicator Description (4 U High-Density Disk Enclosure)
After a high-density disk enclosure is powered on, you can learn about the operating status of
the high-density disk enclosure by observing the indicators on it.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

56

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

4.1 Indicator Description (2 U Controller Enclosure)


After a controller enclosure is powered on, you can learn about the operating status of the
controller enclosure by observing the indicators on it.

Indicators on the Front Panel (S2600T)


Figure 4-1 shows the indicators on the front panel of a controller enclosure (S2600T).
Figure 4-1 Indicators on the front panel of a controller enclosure

Table 4-1 describes the indicators on the front panel of a controller enclosure.
Table 4-1 Description of the indicators on the front panel of a controller enclosure
Module

No.

Indicator

Status and Description

System
enclosure

Controller enclosure
Location indicator

l Blinking blue: The controller


enclosure is being located.
l Off: The disk is working correctly.

Disk
module

Disk module Alarm/


Location indicator

l Steady red: The disk module is


faulty.
l Blinking red: The disk module is
being located.
l Off: The disk module is working
properly.

Disk module Running


indicator

l Steady green: The disk module is


working properly.
l Blinking green: Data transfer is in
progress.
l Off: The disk module is powered
off or powered on incorrectly.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

57

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Module

No.

Indicator

Status and Description

System
enclosure

Controller enclosure
Power indicator

l Steady green: The controller


enclosure is powered on.
l Blinking green: The controller
enclosure is being powered on or
powered off.
l Off: The controller enclosure is
powered off.

Controller enclosure
Alarm indicator

l Steady red: The controller


enclosure is out of service, or an
alarm is generated on it.
l Off: The controller enclosure is
working properly.

Indicators on the Front Panel (S5500T)


Figure 4-2 and Figure 4-3 show the indicators on the front panel of a controller enclosure
(S5500T).
Figure 4-2 Indicators on the front panel of a controller enclosure

Figure 4-3 Indicators on the front panel of a controller enclosure

Table 4-2 describes the indicators on the front panel of a controller enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

58

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Table 4-2 Description of the indicators on the front panel of a controller enclosure
Module

No.

Indicator

Status and Description

System
enclosure

Controller enclosure
Power indicator

l Steady green: The controller


enclosure is powered on.
l Blinking green: The controller
enclosure is being powered on or
powered off.
l Off: The controller enclosure is
powered off.

Disk module

Disk module
Running indicator

l Steady green: The disk module is


working properly.
l Blinking green: Data is being
transferred.
l Off: The disk module is powered off
or incorrectly powered on.

Disk module Alarm/


Location indicator

l Steady red: The disk module is


faulty.
l Blinking red: The disk module is
being located.
l Off: The disk module is working
properly.

System
enclosure

Controller enclosure
Alarm indicator

l Steady red: The controller enclosure


is out of service, or an alarm is
generated on it.
l Off: The controller enclosure is
working properly.

Indicators on the Rear Panel (S2600T)


Figure 4-4 shows the indicators on the rear panel of a controller enclosure.
Figure 4-4 Indicators on the rear panel of a controller enclosure

Table 4-3 describes the indicators on the rear panel of a controller enclosure.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

59

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Table 4-3 Description of the indicators on the rear panel of a controller enclosure
Module

No.

Indicator

Status and Description

Power
module

Power module Running/


Alarm indicator

l Steady green: The power module is


working properly.
l Blinking green: The power input is
correct and the device is powered
off.
l Steady red: The power module is
faulty.
l Blinking red: The power input is
undervoltage or overvoltage.
l Off: No power input.

Fan-BBU
module

Fan-BBU module
Running/Alarm indicator

l Steady green: The BBU is charged


full and the fan is working properly.
l Blinking green: The BBU is being
charged.
l Blinking amber: The BBU is
discharging.
l Steady red: The fan or BBU is
faulty.

Controller

Link/Active indicator of
the 1 Gbit/s iSCSI port

l Steady green: The link to the server


is normal.
l Blinking green: Data transfer is in
progress.
l Off: The link to the application
server is down or no link exists.

Speed indicator of the 1


Gbit/s iSCSI port

l Steady orange: The data transfer


rate between the iSCSI port and the
application server is 1 Gbit/s.
l Off: The data transfer rate between
the iSCSI port and the application
server is less than 1 Gbit/s.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

60

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Module

4 Indicator Introduction

No.

Indicator

Status and Description

Link/Speed indicator of an
8 Gbit/s Fibre Channel
port

l Steady blue: Data is transferred


between the controller enclosure
and the application server at a rate
of 8 Gbit/s.
l Blinking blue: Data is being
transferred.
l Steady green: Data is transferred
between the controller enclosure
and the application server at a rate
of 4 Gbit/s or 2 Gbit/s.
l Blinking green: Data is being
transferred.
l Steady red: The port is faulty.
l Off: The link is down.

Controller Alarm indicator

l Steady red: An alarm is generated


on the controller.
l Off: The controller is working
properly.

Controller Power indicator

l Steady green: The controller is


powered on.
l Blinking green: The system is
being powered on or powered off.
l Off: The controller is powered off.

Indicator of a mini SAS


expansion port

l Steady blue: Data is transferred


between the controller enclosure
and the disk enclosure at a rate of 4
x 6 Gbit/s.
l Steady green: Data is transferred
between the controller enclosure
and the disk enclosure at a rate of 4
x 3 Gbit/s.
l Steady red: The port is faulty.
l Off: The link is down.

Speed indicator of the


management network port

l Steady orange: The data transfer


rate of the management network
port is 1 Gbit/s.
l Off: The data transfer rate of the
management network port is less
than 1 Gbit/s.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

61

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Module

4 Indicator Introduction

No.

Indicator

Status and Description

10

Link/Active indicator of
the management network
port

l Steady green: The link to the server


is normal.
l Blinking green: Data transfer is in
progress.
l Off: The link to the application
server is down or no link exists.

Indicators on the Rear Panel (S5500T)


Figure 4-5 shows the indicators on the rear panel of a controller enclosure.
Figure 4-5 Indicators on the rear panel of a controller enclosure

Table 4-4 describes the indicators on the rear panel of a controller enclosure.
Table 4-4 Description of the indicators on the rear panel of a controller enclosure
Module

No.

Indicator

Status and Description

Power module

Power module
Running/Alarm
indicator

l Steady green: The power module is


working properly.
l Blinking green: The power input is
correct and the device is powered
off.
l Steady red: The power module is
faulty.
l Blinking red: The power input is
undervoltage or overvoltage.
l Off: No power input.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

62

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Module

No.

Indicator

Status and Description

Fan-BBU
module

Fan-BBU Running/
Alarm indicator

l Steady green: The BBU is charged


full and the fan is working properly.
l Blinking green: The BBU is being
charged.
l Blinking amber: The BBU is
discharging.
l Steady red: The fan or BBU is
faulty.

Interface module

Link/Speed indicator
of an 8 Gbit/s Fibre
Channel port

l Steady blue: Data is transferred


between the controller enclosure
and the application server at a rate
of 8 Gbit/s.
l Blinking blue: Data is being
transferred.
l Steady green: Data is transferred
between the controller enclosure
and the application server at a rate
of 4 Gbit/s or 2 Gbit/s.
l Blinking green: Data is being
transferred.
l Steady red: The port is faulty.
l Off: The link is down.

Controller

Controller Alarm
indicator

l Steady red: An alarm is generated


on the controller.
l Off: The controller is working
properly.

Controller Power
indicator

l Steady green: The controller is


powered on.
l Blinking green: The system is being
powered on or powered off.
l Off: The controller is powered off.

Indicator of a mini
SAS expansion port

l Steady blue: Data is transferred


between the controller enclosure
and the disk enclosure at a rate of 4
x 6 Gbit/s.
l Steady green: Data is transferred
between the controller enclosure
and the disk enclosure at a rate of 4
x 3 Gbit/s.
l Steady red: The port is faulty.
l Off: The link is down.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

63

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Module

4 Indicator Introduction

No.

Indicator

Status and Description

Active indicator of
the management
network port

l Blinking orange: Data is being


transferred.

Link indicator of the


management
network port

l Steady green: The link is up.

l Off: No data is being transferred.

l Off: The link is down.

4.2 Indicator Description (4 U Controller Enclosure)


After a controller enclosure is powered on, you can learn about the operating status of the
controller enclosure by observing the indicators on it.

Indicators on the Front Panel


Figure 4-6 shows the indicators on the front panel of a controller enclosure.
Figure 4-6 Indicators on the front panel of a controller enclosure

Table 4-5 describes the indicators on the front panel of a controller enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

64

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Table 4-5 Description of the indicators on the front panel of a controller enclosure
Module

No.

Indicator

Status and Description

System
enclosure

Controller enclosure
Power indicator

l Steady green: The controller


enclosure is powered on.
l Blinking green: The controller
enclosure is being powered on or
powered off.
l Off: The controller enclosure is
powered off.

Controller

Controller Power
indicator

l Steady green: The controller is


powered on.
l Blinking green: The system is
being powered on or powered
off.
l Off: The controller is powered
off.

Controller Alarm
indicator

l Steady red: An alarm is


generated on the controller.
l Off: The controller is working
properly.

BBU module

BBU module Running/


Alarm indicator

l Steady green: The BBU module


is fully charged.
l Blinking green: The BBU
module is being charged.
l Steady amber: A warning alarm
is generated. You are advised to
replace the BBU.
l Blinking amber: The BBU
module is discharging.
l Steady red: The BBU module is
faulty.

System
enclosure

Controller enclosure
Alarm indicator

l Steady red: The controller


enclosure is out of service, or an
alarm is generated on it.
l Off: The controller enclosure is
working properly.

Indicators on the Rear Panel


Figure 4-7 shows the indicators on the rear panel of a controller enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

65

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Figure 4-7 Indicators on the rear panel of a controller enclosure

Table 4-6 describes the indicators on the rear panel of a controller enclosure.
Table 4-6 Description of the indicators on the rear panel of a controller enclosure
Module

No.

Indicator

Status and Description

Power
module

Power module
Running/Alarm
indicator

l Steady green: The power module is


working properly.
l Blinking green: The power input is
correct and the device is powered off.
l Steady red: The power module is
faulty.
l Blinking red: The power input is
undervoltage or overvoltage.
l Off: No power input.

Fan module

Fan module
Running/Alarm
indicator

l Steady green: The fan module is


working properly.
l Steady red: The fan module is faulty.
l Off: The fan module is powered off.

Interface
module

Link/Active
indicator of the 1
Gbit/s iSCSI port

l Steady green: The link to the server is


normal.
l Blinking green: Data transfer is in
progress.
l Off: The link to the application server
is down or no link exists.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

66

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Module

4 Indicator Introduction

No.

Indicator

Status and Description

Link/Speed
indicator of the
Fibre Channel port

l Steady blue: The data transfer rate


between the storage system and the
application server is 8 Gbit/s.
l Blinking blue: Data transfer is in
progress.
l Steady green: The data transfer rate
between the storage system and the
application server is 4 Gbit/s or 2 Gbit/
s.
l Blinking green: Data transfer is in
progress.
l Steady red: The port is faulty.
l Off: The link of the port is down.

Module Power
indicator

l Steady green: The interface module is


working properly.
l Blinking green: The interface module
has a hot swap request.
l Steady red: The interface module is
faulty.
l Off: The interface module is powered
off.

Active indicator of
the management
network port

l Blinking orange: Data is being


transferred.

Link indicator of
the management
network port

l Steady green: The link is up.

Speed indicator of
the 1 Gbit/s iSCSI
port

l Steady orange: The data transfer rate


between the iSCSI port and the
application server is 1 Gbit/s.

l Off: No data is being transferred.

l Off: The link is down.

l Off: The data transfer rate between the


iSCSI port and the application server is
less than 1 Gbit/s.
9

Indicator of a 10
Gbit/s TOE port

l Steady blue: Data is transferred


between the controller enclosure and
the application server at a rate of 10
Gbit/s.
l Blinking blue: Data is being
transferred.
l Steady red: The port is faulty.
l Off: The link is down.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

67

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Module

4 Indicator Introduction

No.

Indicator

Status and Description

10

Indicator of a mini
SAS expansion
port

l Steady blue: Data is transferred


between the controller enclosure and
the disk enclosure at a rate of 4 x 6
Gbit/s.
l Steady green: Data is transferred
between the controller enclosure and
the disk enclosure at a rate of 4 x 3
Gbit/s.
l Steady red: The port is faulty.
l Off: The link is down.

4.3 Indicator Description (2 U SAS Disk Enclosure)


After a disk enclosure is powered on, you can learn about the operating status of the disk
enclosure by observing the indicators on it.

Indicators on the Front Panel


Figure 4-8 shows the indicators on the front panel of a disk enclosure.
Figure 4-8 Indicators on the front panel of a disk enclosure

Table 4-7 describes the indicators on the front panel of a disk enclosure.
Table 4-7 Description of the indicators on the front panel of a disk enclosure
Module

No.

Indicator

Status and Description

System
enclosure

Disk enclosure
Power indicator

l Steady green: The disk enclosure is


powered on.
l Off: The disk enclosure is powered
off.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

68

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Module

No.

Indicator

Status and Description

Disk module

Disk module
Running indicator

l Steady green: The disk module is


working properly.
l Blinking green: Data is being
transferred.
l Off: The disk module is powered off
or incorrectly powered on.

Disk module
Alarm/Location
indicator

l Steady red: The disk module is faulty.


l Blinking red: The disk module is
being located.
l Off: The disk module is working
properly.

System
enclosure

Disk enclosure
Alarm indicator

l Steady red: The disk enclosure is out


of service, or an alarm is generated on
it.
l Off: The disk enclosure is working
properly.

Indicators on the Rear Panel


Figure 4-9 shows the indicators on the rear panel of a disk enclosure.
Figure 4-9 Indicators on the rear panel of a disk enclosure

Table 4-8 describes the indicators on the rear panel of a disk enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

69

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Table 4-8 Description of the indicators on the rear panel of a disk enclosure
Module

No.

Indicator

Status and Description

Power module

Power module
Running/Alarm
indicator

l Steady green: The power module is


working properly.
l Blinking green: The power input is
correct and the device is powered
off.
l Steady red: The power module is
faulty.
l Blinking red: The power input is
undervoltage (including AC poweroff) or overvoltage.
l Off: No power input.

Fan module

Fan module
Running/Alarm
indicator

l Steady green: The fan module is


working properly.
l Steady red: The fan module is faulty.
l Off: The fan module is powered off.

Expansion
module

Indicator of a mini
SAS expansion
port

l Steady blue: The link is up and the


rate is 4 x 6 Gbit/s.
l Steady green: The link is up and the
rate is 4 x 3 Gbit/s.
l Steady red: The expansion port is
faulty.
l Off: The link is down.

Expansion module
Alarm indicator

l Steady red: The expansion module is


faulty.
l Off: The expansion module is
working properly.

Expansion module
Power indicator

l Steady green: The expansion module


is powered on.
l Off: The expansion module is
powered off.

4.4 Indicator Description (4 U SAS Disk Enclosure)


After a disk enclosure is powered on, you can learn about the operating status of the disk
enclosure by observing the indicators on it.

Indicators on the Front Panel


Figure 4-10 shows the indicators on the front panel of a disk enclosure.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

70

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Figure 4-10 Indicators on the front panel of a disk enclosure

Table 4-9 describes the indicators on the front panel of a disk enclosure.
Table 4-9 Description of the indicators on the front panel of a disk enclosure
Module

No.

Indicator

Status and Description

System
enclosure

Disk enclosure
Power indicator

l Steady green: The disk enclosure is


powered on.
l Off: The disk enclosure is powered
off.

Disk module

Disk module
Running indicator

l Steady green: The disk module is


working properly.
l Blinking green: Data is being
transferred.
l Off: The disk module is powered off
or incorrectly powered on.

Disk module
Alarm/Location
indicator

l Steady red: The disk module is faulty.


l Blinking red: The disk module is
being located.
l Off: The disk module is working
properly.

System
enclosure

Disk enclosure
Alarm indicator

l Steady red: The disk enclosure is out


of service, or an alarm is generated on
it.
l Off: The disk enclosure is working
properly.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

71

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Indicators on the Rear Panel


Figure 4-11 shows the indicators on the rear panel of a disk enclosure.
Figure 4-11 Indicators on the rear panel of a disk enclosure

Table 4-10 describes the indicators on the rear panel of a disk enclosure.
Table 4-10 Description of the indicators on the rear panel of a disk enclosure
Module

No.

Indicator

Status and Description

Power module

Power module
Running/Alarm
indicator

l Steady green: The power module is


working properly.
l Blinking green: The power input is
correct and the device is powered
off.
l Steady red: The power module is
faulty.
l Blinking red: The power input is
undervoltage (including AC poweroff) or overvoltage.
l Off: No power input.

Fan module

Fan module
Running/Alarm
indicator

l Steady green: The fan module is


working properly.
l Steady red: The fan module is faulty.
l Off: The fan module is powered off.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

72

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Module

No.

Indicator

Status and Description

Expansion
module

Indicator of a mini
SAS expansion
port

l Steady blue: The link is up and the


rate is 4 x 6 Gbit/s.
l Steady green: The link is up and the
rate is 4 x 3 Gbit/s.
l Steady red: The expansion port is
faulty.
l Off: The link is down.

Expansion module
Alarm indicator

l Steady red: The expansion module is


faulty.
l Off: The expansion module is
working properly.

Expansion module
Power indicator

l Steady green: The expansion module


is powered on.
l Off: The expansion module is
powered off.

4.5 Indicator Description (File Engine)


After a file engine is powered on, you can learn about the operating status of the file engine is
working properly.

Indicators on the Front Panel


Figure 4-12 shows the indicators on the front panel of a file engine.
Figure 4-12 Indicators on the front panel of a file engine

Table 4-11 describes the indicators on the front panel of a file engine.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

73

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Table 4-11 Description of the indicators on the front panel of a file engine
Module

No.

Indicator

Status and Description

System
enclosure

Power indicator
of the file engine

l Steady green: The file engine is


powered on.
l Blinking green: The file engine is
being powered on or powered off.
l Off: The file engine is powered off.

Controller

Controller Power
indicator

l Steady green: The controller is


powered on.
l Blinking green: The system is being
powered on or powered off.
l Off: The controller is powered off.

Controller Alarm
indicator

l Steady red: An alarm is generated on


the controller.
l Off: The controller is working
properly.

System
enclosure

Power Alarm
indicator of the
file engine

l Steady red: The file engine is out of


service, or an alarm is generated on it.
l Off: The file engine is working
properly.

Indicators on the Rear Panel


Figure 4-13 shows the indicators on the rear panel of a file engine.
Figure 4-13 Indicators on the rear panel of a file engine

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

74

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Table 4-12 describes the indicators on the rear panel of a file engine.
Table 4-12 Description of the indicators on the rear panel of a file engine
Module

No.

Indicator

Status and Description

Power module

Power module
Running/Alarm
indicator

l Steady green: The power module is


working properly.
l Blinking green: The power input is
correct and the device is powered off.
l Steady red: The power module is
faulty.
l Blinking red: The power input is
undervoltage (including AC poweroff) or overvoltage.
l Off: No power input.

Fan module

Fan module
Running/Alarm
indicator

l Steady green: The fan module is


working properly.
l Steady red: The fan module is faulty.
l Off: The fan module is powered off.

Interface
module

Link/Active
indicator of a 1
Gbit/s iSCSI port

l Steady green: The link is up.


l Blinking green: Data is being
transferred.
l Off: The link is down.

Management
module

Interface
module

Active indicator
of the
management
network port

l Blinking orange: Data is being


transferred.

Link indicator of
the management
network port

l Steady green: The link is up.

l Off: No data is being transferred.

l Off: The link is down.

Speed indicator of l Steady orange: Data is transferred


a 1 Gbit/s iSCSI
between the file engine and the
port
application server at a rate of 1 Gbit/
s.
l Off: Data is transferred between the
file engine and the application server
at a rate lower than 1 Gbit/s.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

75

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Module

4 Indicator Introduction

No.

Indicator

Status and Description

Link/Speed
indicator of an 8
Gbit/s FC port

l Steady blue: Data is transferred at a


rate of 8 Gbit/s.
l Blinking blue: Data is being
transferred.
l Steady green: Data is transferred at a
rate of 4 Gbit/s or 2 Gbit/s.
l Blinking green: Data is being
transferred.
l Steady red: The port is faulty.
l Off: The link is down.

4.6 Indicator Description (Data Switch)


After a data switch is powered on, you can learn about the operating status of the data switch by
observing the indicators on it.

Front View
Figure 4-14 shows the front view of data switch.
Figure 4-14 Front view of data switch

1 Data switch Power indicator

2 AC power module Running/Alarm indicator

3 Fan module Running/Alarm indicator

4 Data switch Alarm indicator

Table 4-13 lists the states and corresponding meanings of indicators on a data switch.
Table 4-13 Checklist for indicators on a data switch
No.

Indicator Name

Status and Description

Data switch Power


indicator

l Steady green: The data switch is working


properly.
l Blinking green: The data switch is being
powered on.
l Off: The data switch is powered off.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

76

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

No.

Indicator Name

Status and Description

Power Running/Alarm
indicator

l Steady green: The power module is working


properly.
l Steady red: The power module is faulty.
l Off: The power module is powered off.

Fan Running/Alarm
indicator

l Steady green: The fan module is working


properly.
l Steady red: The fan module is faulty.
l Off: The fan module is powered off.

Data switch Alarm


indicator

l Steady red: The data switch is faulty.


l Off: The data switch is working properly.

Rear View
Figure 4-15 shows the rear view of a data switch.
Figure 4-15 Rear view of a data switch

1 Data switch Power indicator

2 Link/Speed indicator of a PCIe port

3 Data switch Alarm indicator

Table 4-14 lists the states and corresponding meanings of indicators on a data switch.
Table 4-14 Checklist for indicators on a data switch
No.

Indicator Name

Status and Description

Data switch Power


indicator

l Steady green: The data switch is working


properly.
l Blinking green: The data switch is being
powered on.
l Off: The data switch is powered off.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

77

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

No.

Indicator Name

Status and Description

Link/Speed indicator of a
PCIe port

l Steady blue: The data transfer rate of the PCIe


port is 5 Gbit/s.
l Steady green: The data transfer rate of the PCIe
port is 2.5 Gbit/s.
l Steady red: The port is faulty.
l Off: The link of the port is down.

Data switch Alarm


indicator

l Steady red: The data switch is faulty.


l Off: The data switch is working properly.

4.7 Indicator Description (4 U High-Density Disk


Enclosure)
After a high-density disk enclosure is powered on, you can learn about the operating status of
the high-density disk enclosure by observing the indicators on it.

Indicators on the Front Panel


Figure 4-16 shows the indicators on the front panel of a high-density disk enclosure.
Figure 4-16 Indicators on the front panel of a high-density disk enclosure

Table 4-15 describes the indicators on the front panel of a high-density disk enclosure.
Table 4-15 Description of the indicators on the front panel of a high-density disk enclosure

Issue 03 (2014-11-05)

Module

No.

Indicator

Status and Description

System
enclosure

High-density disk
enclosure
Location
indicator

l Blinking blue: The high-density disk


enclosure has been located.
l Off: The high-density disk enclosure is not
located.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

78

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Module

4 Indicator Introduction

No.

Indicator

Status and Description

High-density disk
enclosure
overtemperature
Alarm indicator

l Steady red: The temperature of the highdensity disk enclosure is too high.

High-density disk
enclosure internal
module Alarm
indicator

l Steady red: Internal disk modules of the highdensity disk enclosure are faulty.

l Off: The temperature of the high-density disk


enclosure is within the normal range.

l Blinking red: Internal disk modules of the


high-density disk enclosure fail.
l Off: Internal disk modules are running
correctly.

High-density disk
enclosure rear
module Alarm
indicator

l Steady red: The number of rear field


replaceable units (FRUs) is fewer than half of
that in standard configuration or rear FRUs are
faulty.
NOTE
Modules on the rear of the high-density disk
enclosure include power modules, fan modules, and
expansion modules.

l Off: Rear FRUs are running correctly.


5

High-density disk
enclosure Power
indicator

l Steady green: The high-density disk enclosure


is powered on.

High-density disk
enclosure Alarm
indicator

l Steady red: The high-density disk enclosure is


faulty.

l Off: The high-density disk enclosure is not


powered on.

l Off: The high-density disk enclosure is


running correctly.

Indicators on the Rear Panel


Figure 4-17 shows the indicators on the rear panel of a high-density disk enclosure.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

79

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Figure 4-17 Indicators on the rear panel of a high-density disk enclosure

Table 4-16 describes the indicators on the rear panel of a high-density disk enclosure.
Table 4-16 Description of the indicators on the front panel of a high-density disk enclosure
Module

No.

Indicator

Status and Description

Power
module

Power module Running


indicator

l Steady green: The power module


is running correctly.
l Off: The power module is not
power on or undervoltage,
overvoltage, overtemperature, or
short-circuit occurs.

Expansion
module

Indicator of a mini SAS HD


expansion port

l Steady blue: The link is up and the


rate is 4 x 6 Gbit/s.
l Steady green: The link is up and
the rate is 4 x 3 Gbit/s.
l Steady red: The expansion port is
faulty.
l Off: The link is down.

Fan
module

Fan module Running/Alarm


indicator

l Steady green: The fan module is


running correctly.
l Steady red: The fan module is
faulty.
l Off: The fan module is not
powered on.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

80

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

4 Indicator Introduction

Module

No.

Indicator

Status and Description

Expansion
module

Expansion module Alarm


indicator

l Steady red: The expansion


module is faulty.
l Blinking red and Running
indicator of the expansion module
blinking green: The expansion
module is being located.
l Off: The expansion module is not
powered or is running correctly.

Expansion module Power


indicator

l Steady green: The expansion


module is running correctly.
l Blinking green and Running
indicator of the expansion module
blinking red: The expansion
module is being located.
l Off: The expansion module is not
powered on.

Indicators on a Disk Module.


Figure 4-18 shows the indicators on a disk module.
Figure 4-18 Disk module indicator

Table 4-17 describes the indicators on a disk module.


Table 4-17 Description of the indicators on a disk module
Module

Indicator

Status and Description

Disk
module

Disk module indicator

l Steady green: The disk module is running


correctly.
l Steady red: The disk module is faulty.
l Blinking blue: The disk module has been
located.
l Blinking red: The disk module will be failed.
l Off: The disk module is not powered on.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

81

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

5 Device Cables

Device Cables

About This Chapter


Device cables used in the storage system include power cables, ground cables, and signal cables.
This chapter shows these cables and describes their functions and specifications.
NOTE

The cable specifications vary according to the installation site. This chapter uses only one type of
specifications for each device cable type as an example.

5.1 Power Cable


Power cables include AC power cables and power distribution unit (PDU) power cables. The
power cable transfers power for the device inside the cabinet. One end of the power cable is
inserted to the socket on the controller enclosure or a disk enclosure, and the other end connects
to the external power supply.
5.2 Ground Cable
Ground cables ground the controller enclosures and disk enclosures to ensure safe operation of
the storage system.
5.3 Network Cable
A network cable connects to a 1 Gbit/s iSCSI port or the management network port in the storage
system.
5.4 Serial Cable
A serial cable is used to connect the serial port of the storage system to the serial port of the
maintenance terminal.
5.5 Mini SAS Cable
A mini SAS cable, mini SAS HD cable, and mini SAS to mini SAS HD cable are used to connect
to expansion ports.
5.6 Optical Fiber
An optical fiber is used to connect Fibre Channel ports, 10 Gbit/s TOE ports, or 10 Gbit/s FCoE
ports.
5.7 AOC Cable
An active optical cable (AOC) connects a PCIe port on a controller enclosure to a data switch.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

82

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

5 Device Cables

5.1 Power Cable


Power cables include AC power cables and power distribution unit (PDU) power cables. The
power cable transfers power for the device inside the cabinet. One end of the power cable is
inserted to the socket on the controller enclosure or a disk enclosure, and the other end connects
to the external power supply.
Each AC power module of storage system is configured with one AC power cable.
Figure 5-1 shows an AC power cable.
Figure 5-1 AC power cable

Figure 5-2 shows a PDU power cable.


Figure 5-2 PDU power cable

5.2 Ground Cable


Ground cables ground the controller enclosures and disk enclosures to ensure safe operation of
the storage system.
Figure 5-3 shows a ground cable.
Figure 5-3 Ground cable

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

83

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

5 Device Cables

5.3 Network Cable


A network cable connects to a 1 Gbit/s iSCSI port or the management network port in the storage
system.
In the storage system, a network cable is used to:
l

Connect the controller enclosure through a 1 Gbit/s iSCSI port to an application server
Direct-connection networking
One end of the network cable is connected to the iSCSI port of the controller enclosure
and the other end to the NIC port of the application server.
GE switch networking
One end of a network cable is connected to the iSCSI port on the controller enclosure
and the other end to a port on a GE switch. One end of another network cable is connected
to another port on the GE switch and the other end to the NIC port of the application
server.

Connect the controller enclosure to the maintenance terminal


One end of the network cable is connected to the management network port of the controller
enclosure and the other end to the network port of the maintenance terminal.

Connect the controller enclosure to the data switch


One end of the network cable is connected to the maintenance network port of the controller
enclosure and the other end to the management network port of the data switch.

Figure 5-4 shows a network cable.


Figure 5-4 Network cable

5.4 Serial Cable


A serial cable is used to connect the serial port of the storage system to the serial port of the
maintenance terminal.
One end of the serial cable is an RJ45 connector, and the other end is a DB-9 connector. The
RJ45 connector of the serial cable connects to the serial port of the controller enclosure and the
DB-9 connector connects to the management network port of the maintenance terminal.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

84

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

5 Device Cables

Figure 5-5 shows a serial cable.


Figure 5-5 Serial cable

5.5 Mini SAS Cable


A mini SAS cable, mini SAS HD cable, and mini SAS to mini SAS HD cable are used to connect
to expansion ports.
A mini SAS cable connects a controller enclosure to a disk enclosure or connects a disk enclosure
to another disk enclosure.
l

Connection between a controller enclosure and a disk enclosure


One end of the mini SAS cable is connected to the mini SAS expansion port of the controller
enclosure and the other end to the mini SAS expansion port of the disk enclosure.

Connection between a controller enclosure and a high-density disk enclosure


One end of the mini SAS cable is connected to the mini SAS expansion port of the controller
enclosure and the other end to the mini SAS HD expansion port of the high-density disk
enclosure.

Connection between two disk enclosures


One end of the mini SAS cable is connected to the mini SAS expansion port of a disk
enclosure and the other end to the mini SAS expansion port of the other disk enclosure.

Connection between two high-density disk enclosures


One end of the mini SAS HD cable is connected to the mini SAS HD expansion port of a
high-density disk enclosure and the other end to the mini SAS HD expansion port of the
other high-density disk enclosure.

Figure 5-6 shows a mini SAS cable.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

85

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

5 Device Cables

Figure 5-6 Mini SAS cable

Figure 5-7 shows a mini SAS HD cable.


Figure 5-7 Mini SAS HD cable

Figure 5-8 shows a mini SAS to mini SAS HD cable.


Figure 5-8 Mini SAS to mini SAS HD cable

5.6 Optical Fiber


An optical fiber is used to connect Fibre Channel ports, 10 Gbit/s TOE ports, or 10 Gbit/s FCoE
ports.
Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

86

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

5 Device Cables

An optical fiber connects the controller enclosure to an application server through a port.
l

Direct-connection networking
One end of the optical fiber is connected to the Fibre Channel port of the controller
enclosure and the other end to the Fibre Channel HBA port of the application server.
One end of the optical fiber is connected to the 10 Gbit/s TOE port or 10 Gbit/s FCoE
port of the controller enclosure and the other end to the 10GE HBA port of the
application server.

Fibre Channel switch networking


One end of one optical fiber is connected to the Fibre Channel port, 10 Gbit/s TOE port,
or 10 Gbit/s FCoE port of the controller enclosure and the other end to a port on a Fibre
Channel switch. One end of another optical fiber is connected to another port on the Fibre
Channel switch and the other end to the Fibre Channel HBA port of the application server.

Figure 5-9 shows an optical fiber.


Figure 5-9 Optical fiber

NOTE

The storage system does not support single-mode optical fibers or single-mode optical transceivers.

5.7 AOC Cable


An active optical cable (AOC) connects a PCIe port on a controller enclosure to a data switch.
One end of an AOC cable connects to a PCIe port on a controller enclosure, and the other end
connects to a data switch.
Figure 5-10 shows an AOC cable.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

87

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

5 Device Cables

Figure 5-10 AOC cable

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

88

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

6 Environment Requirements

Environment Requirements

The chapter describes the environment requirements that ensure the normal running of devices,
including the temperature and humidity, altitude, heat dissipation and air flow, and noise of
storage devices.

Temperature and Humidity


Table 6-1 lists the requirements of the storage devices on temperature and humidity.
Table 6-1 Requirements of the storage devices on temperature and humidity
Parameter

Condition

Requirement

Temperature

Operating temperature

Controller enclosure and disk enclosure when the


altitude is lower than 1,800 m (5,904 ft.): 5C
(41F) to 40C (104F)
5C (41F) to 30C (86F) when the altitude is
between 1,800 m (5,904 ft.) and 3,000 m (9,840
ft.)

Humidity

Storage temperature

Controller enclosure and disk enclosure: -20C


(-4F) to +60C (140F)

Operating humidity

5% RH to 90% RH

Storage humidity

5% RH to 95% RH

Particle and Corrosive Airborne Contaminants


Table 6-2 lists particle and corrosive airborne contaminants.
Table 6-2 particle and corrosive airborne contaminants

Issue 03 (2014-11-05)

Parameter

Requirement

Particle Contaminants

ISOa 14664-1 Class8

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

89

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

6 Environment Requirements

Parameter

Requirement

Corrosive Airborne Contaminants

l The copper corrosion rate is less than 300 b/


month (according to the ANSIc/
ISAd-71.04-1985 severity level G1).
l The silver corrosion rate is less than 200 /
month.

a: ISO(International Organization for Standardization).


b: is a unit of length equal to 1/10000000000 (one ten billionth) of a meter.
c: ANSI(American National Standards Institute).
d: ISA(Instrument Society of America).

To control particle and corrosive airborne contaminants under the density limits, perform the
following operations:
l

Do not set up the equipment room in an area with a high corrosive air density, such as a
chemical factory.

Do not make the entrance of the equipment room face a pollution source.

Use an effective filter to process the air flowing into the equipment room, and a filtering
system to periodically clean the air already in the equipment room.

Use environment-friendly heat insulation rather than sulfurated rubber and plastic heat
installation.

Test the particle contaminants and corrosive airborne contaminants by professional


organizations periodically.

Keep unused batteries away from devices. It is recommended to keep unused batteries in
different rooms.

Heat Dissipation and Air Flow


The heat dissipation mode of the storage system is described as follows:
l

The controller enclosure adopts the heat dissipation mode of front absorption and back
dissipation.
The cool air enters from the gaps between the front controllers or BBUs and the rear
modules in the controller enclosure, passes through the midplane (the air from the modules
whirls and converges with the air from the front inlet of the midplane), cools the power
modules, controllers, and interface modules, and then is discharged by the fans. The
controller enclosure automatically adjusts the rotation speed of the fans according to the
operating temperature, thus ensuring heat dissipation for the system.

The disk enclosure adopts the heat dissipation mode of front absorption and back
dissipation.
The cool air enters from the gaps between the disks, passes through the midplane into the
power modules and expansion modules area, cools the power modules and expansion
modules, and is discharged by the fans. The disk enclosure automatically adjusts the

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

90

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

6 Environment Requirements

rotation speed of the fans according to the operating temperature, thus ensuring heat
dissipation for the system.
For better maintenance, ventilation, and heat dissipation, pay attention to the following when
installing the storage system to the cabinet:
l

To ensure smooth ventilation, the cabinet should be at least 100 cm (39.4 inch) away from
the walls and at least 120 cm (47.28 inch) away from another cabinet (in front of or behind
this one).

To keep air convecting between the cabinet and the equipment room, no enclosed space is
allowed in the cabinet. 1U (44.45 mm, 1.75 inch) space should be left above and below
each device.

Noise
Table 6-3 lists the maximum noise generated by the storage system when the ambient
temperature is 25C (77F).
Table 6-3 Noise parameters of the storage system

Issue 03 (2014-11-05)

Parameter

Value

Noise power

< 72 dBA

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

91

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

7 Standard Compliance

Standard Compliance

The chapter describes the protocol standards, the safety specifications and electromagnetic
compatibility (EMC) standards, the industry standards that the storage system complies with.

Protocol Standards
Table 7-1 lists the protocol standards that the storage system complies with.
Table 7-1 Protocol standards
Name

Standard No.

SCSI system

FC-PH: ANSI X3.230


FC-PH2: ANSI X3.297
SCSI-FCP: ANSI X.269
FC-AL: ANSI X.272
FC-AL-2: ANSI NCITS 332-1999
FC-SW: ANSI NCITS 321
FC-SW-2: ANSI NCITS 355-2001
FC-GS: ANSI X.288 (for FC switch)
FC-GS2: ANSI NCITS 288 (for FC switch)
SAS Serial Attached SCSI-1.1 (SAS-1.1)
SAS Serial Attached SCSI-2.0 (SAS-2.0)
T10/1562D Rev.05 Serial Attached SCSI (SAS)
T10/1601D Rev.07 Serial Attached SCSI Model-1.1
(SAS-1.1)
T10/1601D Rev.07 Serial Attached SCSI Model-1.1
(SAS-2.0)

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

92

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Name

7 Standard Compliance

Standard No.
SFF 8301 form factor of 3.5' disk drive
SFF 8323 3.5' disk drive form factor with serial connector
SFF 8482 SAS plug connector
SCSI 3 SAM-2: ANSI INCITS 366-2003
SPC-2: ANSI INCITS 351-2001
SBC: ANSI INCITS 306-1998
PICMG3.0 Advanced Telecommunications Computing
Architecture
PICMG3.1 Ethernet/fiber Channel Over PICMG3.0

TCP/IP system

SNMP v1
SNMP v2c
SNMP v3

PCIe system

PCI Express Base Specification R1.1


PCI Express to PCI or PCI-X Bridge Specification v1.0
PCI Express Base Specification v2.0

Safety Specifications and EMC Standards


Table 7-2 lists the safety specifications and EMC standards that the storage system complies
with.
Table 7-2 Safety specifications and EMC standards
Name

Standard No.

China safety standard

GB 4943

North America safety


standard

UL 60950-1

European safety directive

LVD 2006/95/EC

European safety standard

EN 60950-1

China EMC standard

GB9254-2008 (idt CISPR 22: 2006)


GB17625.1-2003 (idt IEC 61000-3-2: 2001)

Canada EMC standard

ICES-003: 2004
CAN/CSA-CEI/IEC CISPR 22:02

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

93

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Name

Standard No.

North America EMC


standard

FCC, CFR 47 Part 15, Subpart B

European EMC directive

EMC Directive 2004/108/EC

European EMC standard

EN 55022

7 Standard Compliance

EN 61000-3-2
EN 61000-3-3
ETSI EN 300 386
EN 55024
Japan standard

VCCI V-3

Australia standard

AS/NZS CISPR 22

Industry Standards
Table 7-3 lists the industry standards that the storage system complies with.
Table 7-3 Industry standards
Name

Standard No.

Ethernet

IEEE 802.3

Fast Ethernet

IEEE 802.3u

Gigabit Ethernet

IEEE 802.3z
IEEE 802.3ab

Issue 03 (2014-11-05)

10-Gigabit Ethernet

IEEE 802.3ae

IEEE standard test access


port and boundary-scan
architecture

IEEE 1149.1-2001

Procedure for failure modes


and effects analysis (FMEA)

IEC 812

Presentation of reliability,
maintainability and
availability predictions

IEC 863

ETSI standard
(environment)

ETS 300 019

ETSI standard (power)

ETS 300 132

ETSI standard (noise)

ETS 300 753

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

94

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Issue 03 (2014-11-05)

7 Standard Compliance

Name

Standard No.

ETSI standard
(environment)

ETS 300 119

ETSI standard (grounding)

ETS 300 253

ITUT standard (grounding)

ITUT K.27

Environmental protection

ECMA TR/70

Reliability

GR-929, Telcordia SR-332

Clean room and related


controlled environments

ISO 14664-1 Class8

Airborne contaminants and


environment standards

ANSI/ISA-71.04-1985 severity level G1

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

95

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

8 Certifications

Certifications

The chapter describes the certifications that the storage system passes.
Table 8-1 lists the reliability certifications that the storage system passes.
Table 8-1 Reliability certifications
Name

Icon

Description

CB

None

The IEC System for Conformity


Testing and Certification of Electrical
Equipment (IECEE) is based on the use
of specific IEC standards for electrical
equipment. The Certification Bodies
(CB) Scheme is applicable to electrical
equipment within the scope of IEC
standards for safety, accepted for use in
the IECEE. The Scheme becomes
operative for such standards as soon as
at least one National Certification Body
has declared their recognition of CB
Test Certificates. The CB scheme is
designed for eliminating the
international commerce barriers
resulted from the compliance with
certifications and approval guidelines
of different countries.
The CB Scheme is based on IEC
standards. If member countries'
national standards are not completely
consistent with IEC standards, the
differences are allowed but must be
disclosed to the other members. A CB
test certificate is used in the Scheme to
prove that a tested product sample has
passed CB tests and meets related IEC
and member countries' requirements.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

96

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Name

Icon

CCC

8 Certifications

Description
CCC stands for China Compulsory
Certification.
According to Regulations on
Compulsory Product Certification
issued by General Administration of
Quality Inspection, Supervision and
Quarantine of the People's Republic of
China, Certification and Accreditation
Administration of the People's
Republic of China organizes and
implements CCC of products related to
human health and safety, animal and
plant life and health, environmental
protection, and public security.

FCC

None

Federal Communications Commission


(FCC) authorizes and manages all RF
transmission facilities and devices
except for those used by the federal
government. It is also responsible for
the environmental damages generated
by the facilities and devices it approves.

IC

None

Industry Canada (IC) sets up the test


standards for analog and digital
terminal devices and specifies
corresponding EMC certificates that all
import electronic products must obtain.

UL

Underwriters Laboratories Inc. (UL):


The UL is a non-profit agency engaged
in product safety testing.
UL is a certification method of
American Nationally Recognized
Testing Laboratory (NRTL). UL has its
own certification system for the entire
system, components, and materials. All
electric products that are exported to the
USA must pass the UL certification.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

97

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Name
CE

Icon

8 Certifications

Description
Conformite Europeenne (CE):
Products marked with CE conform to
EMC (2004/108/EC) and low-voltage
(2006/95/EC) specifications published
by EU.
If this product has telecommunication
functionality, the R_TTE Directive
(1999/5/EC) that complies with the
directives mentioned previously
implies conformity to the following
European norms (in parentheses are the
equivalent international standards and
regulations):
l EN 55022 (CISPR 22)-Electro
Magnetic Interference
l EN 55024 (IEC61000-4-2, 3, 4, 5,
6, 8, 11)-Electro Magnetic
Immunity
l EN 60950 (IEC 60950)-Product
Safety

Issue 03 (2014-11-05)

CU

The Customs Union comprised of


Russia, Belrus, and Kazakhstan comply
with No. 768 Technical Regulations of
the Customs Union on Safety of LowVoltage Equipment that has been
compulsively effective since February
15, 2013. The technical regulations
cover an extensive range of electrical
products that work under the voltage
from 50 V AC to 1000 V AC and from
75 V DC to 1500 V DC, including
household appliances, audio and video
devices, IT devices, and lighting
devices. CU's certificate is valid for five
years.

C-TICK

A mandatory certification issued by


Australian Communications Authority
(ACA) for communication equipment,
mainly concerning EMC requirements.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

98

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

8 Certifications

Name

Icon

Description

SONCAP

None

As required by Standards Organization


of Nigeria, products exported to
Nigeria must be certified by SON
Conformity Assessment Program
(SONCAP) before custom clearance.
As SONCAP aims at protecting human
safety, its standards are also concerned
about safety requirements in addition to
performance.

SASO

None

Saudi Arabian Standards Organization


(SASO), authorized by Saudi Arabian
government, organizes and implements
International Conformity Certification
Program (ICCP) for market access.
Products exported to Saudi Arabia must
meet SASO's market access
requirements and obtain the COC
certificate before custom clearance.

Mexico
COC

None

On august 17, 2010, Mexico


government issued a new resolution. In
this resolution, Mexico announced that
Mexico recognizes NRTL certificates
corresponding to NOM 001/016/019
standards and that importers can use
COC certificates issued by NRTL
organizations for custom clearance.

VCCI

None

Voluntary Control Council for


Interference (VCCI) is a Japanese
organization governing
electromagnetic interference.

Table 8-2 lists the environmental protection certifications that the storage system complies with.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

99

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

8 Certifications

Table 8-2 Environmental protection certifications


Name

Icon

Description

REACH

None

REACH is short for REGULATION


concerning the Registration,
Evaluation, Authorization and
Restriction of Chemicals of the
European Union (EU). REACH
requires all chemical products that are
both imported and produced in Europe
must be registered, assessed,
authorized, and restricted. In this way,
customers can easily recognize the
chemical elements. Therefore, both
humans and environment are protected.

RoHS

The restriction of the use of certain


hazardous substances in electrical and
electronic equipment (RoHS) is the
directive that restricts the use of certain
hazardous substances in the electrical,
electronic equipment.
RoHS is an EU compulsory standard
that is designed to regulate the materials
and the technical standard of the
electrical and electronic products. In
this way, it does good to human health
and environment protection. That is,
the six hazardous substances of lead
(Pb), mercury (Hg), cadmium (Cd),
hexavalent chromium (Cr6 +),
polybrominated biphenyl (PBB),
polybrominated diphenyl ethers
(PBDE) cannot exceed the specified
limits.

WEEE

The EU Directive on Waste of Electric


and Electronic Equipment (WEEE).
Electrical and electronic products sold
in the EU market must comply with this
directive and have the mark of cross out
wheeled bin.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

100

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

9 Hardware Specifications

Hardware Specifications

Hardware specifications cover the hardware configuration, port specifications, disk


specifications, dimensions, weight, electrical specifications, and reliability specifications.
Table 9-1 describes the hardware specification categories to help you quickly find out the
specification information you need.
Table 9-1 Description of hardware specification categories

Issue 03 (2014-11-05)

Category

Description

Hardware
configuration

Describes the configuration of major hardware components, such as


processors, memory capacity, disks, and ports.

Port
specifications

Describes the port specifications, such as the maximum number of ports


provided by each type of interface module and the maximum number
of interface modules supported by each controller.

Disk
specifications

Describes the dimensions, rotational speed, capacity, and weight of each


type of disk.

Dimensions and
weight

Describes the dimensions and weight of controller enclosures and disk


enclosures.

Electrical
specifications

Describes the electrical specifications of controller enclosures and disk


enclosures.

Reliability
specifications

Describes the reliability specifications of the S5000T series storage


systems.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

101

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

9 Hardware Specifications

Hardware Configuration
Item

S2600T

S5500T

S5600T

S5800T

S6800T

Processor
(per
controller)

1 x processors

1 x dual-core
processors

1 x quadcore
processors

2 x quadcore
processor
s

2 x hexcore
processor
s

Memory
capacity
(per
controller)

8 GB

8 GB/16 GB

12 GB/24
GB

48 GB/96
GB

96 GB/
192 GB

Maximum
number of
controllers

Maximum
number of
disks

276

528

1152

1440

1440

Controller
enclosure
configurati
on

12 x 3.5-inch
disks per 2 U
controller
enclosure

l 24 x 2.5-inch
disks per 2 U
controller
enclosure

4 U controller enclosure without


having the capability to house disks

l 12 x 3.5-inch
disks per 2 U
controller
enclosure

Issue 03 (2014-11-05)

Supported
disk
enclosure
types

l 4 U SAS disk
enclosure

l 2 U SAS disk enclosure

l 4 U SAS highdensity disk


enclosure

l 4 U SAS high-density disk enclosure

Supported
disk types

3.5-inch SAS/3.5inch NL-SAS/


3.5-inch SSD

l 2.5-inch SAS/2.5-inch SSD

Supported
front-end
hosts and
hotswappable
interface
modules

l 8 Gbit/s Fibre
Channel

l 8 Gbit/s Fibre Channel

l 16 Gbit/s
Fibre Channel

l 1 Gbit/s GE

l 1 Gbit/s GE
l 10 Gbit/s TOE

l 4 U SAS disk enclosure

l 3.5-inch SAS/3.5-inch NL-SAS/3.5-inch SSD

l 16 Gbit/s Fibre Channel


l 10 Gbit/s TOE
l 10 Gbit/s FCoE (two ports)
l 10 Gbit/s FCoE (four ports)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

102

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

9 Hardware Specifications

Item

S2600T

S5500T

S5600T

S5800T

Number of
supported
hotswappable
interface
modules
(per
controller)

S6800T

Port Specifications

Issue 03 (2014-11-05)

Port
Specificati
ons

S2600T

S5500T

Maximum
number of
ports
provided by
each 8 Gbit/s
Fibre
Channel
interface
module

4 x front-end ports

Maximum
number of 8
Gbit/s Fibre
Channel
ports (per
controller)

Maximum
number of
ports
provided by
each 16 Gbit/
s Fibre
Channel
interface
module

2 x front-end ports

Maximum
number of 16
Gbit/s Fibre
Channel
ports (per
controller)

S5600T

S5800T

16

20

10

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

S6800T

103

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Port
Specificati
ons

S2600T

Maximum
number of
ports
provided by
each 1 Gbit/s
GE interface
module

4 x front-end ports

Maximum
number of 1
Gbit/s GE
ports (per
controller)

10

Maximum
number of
ports
provided by
each 10 Gbit/
s TOE
interface
module

4 x front-end ports

Maximum
number of 10
Gbit/s TOE
ports (per
controller)

Maximum
number of
ports
provided by
each 10 Gbit/
s FCoE
interface
module (four
ports)

4 x front-end ports

Maximum
number of 10
Gbit/s FCoE
ports (per
controller)

Issue 03 (2014-11-05)

S5500T

9 Hardware Specifications

S5600T

S5800T

16

20

16

20

16

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

S6800T

20

104

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Port
Specificati
ons

S2600T

S5500T

Maximum
number of
ports
provided by
each 10 Gbit/
s FCoE
interface
module (two
ports)

2 x front-end ports

Maximum
number of 10
Gbit/s FCoE
ports (per
controller)
Maximum
number of
ports
provided by
each 5 Gbit/s
PCIe
interface
module

Maximum
number of 5
Gbit/s PCIe
ports (per
controller)

Issue 03 (2014-11-05)

9 Hardware Specifications

S5600T

S5800T

S6800T

10

Used for the connection of multiple controllers. Each module


has two ports.

Maximum
number of
ports
provided by
each 6 Gbit/s
SAS
expansion
module

2 x back-end ports

Maximum
number of
mini SAS
expansion
ports (per
controller)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

10

105

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

9 Hardware Specifications

Port
Specificati
ons

S2600T

S5500T

S5600T

S5800T

Maximum
number of
disk
enclosures

l Disk
enclosure
(24
disks): 11

l Disk
enclosure
(24
disks): 22

l Disk
enclosure
(24
disks): 48

l Disk enclosure (24 disks):


60

l Highdensity
disk
enclosure
:3

l Highdensity
disk
enclosure
:7

l Highdensity
disk
enclosure
: 15

Length of an
expansion
SAS cable

S6800T

l High-density disk
enclosure: 19

1 m (3.28 ft.), 1 m (3.28 ft.), 3 m (9.84 ft.), 6 m (19.68 ft.)


3 m (9.84 ft.)

Disk Specifications
Disk
Type

Dimens
ions

Rotational
Speed

Weight

Power
Consumption
(Working/Idle)

Capacity

SAS

3.5
inches

15k rpm

0.8 kg
(1.76 lb)

18 W/14 W

300 GB/600 GB

2.5
inches

10k rpm

0.21 kg
(0.46 lb)

7.9 W/4.4 W

300 GB/600 GB/


900 GB

NLSAS

3.5
inches

7.2k rpm

0.72 kg
(1.59 lb)

12.8 W/8.6 W

2 TB/3 TB/4 TB

SSD

2.5
inches

0.19 kg
(0.42 lb)

9.48 W/7.2 W

100 GB

10.2 W/7.2 W

200 GB

9.1 W/7.6 W

400 GB

9.7 W/8.3 W

600 GB

9.48 W/7.2 W

100 GB

10.2 W/7.2 W

200 GB

9.1 W/7.6 W

400 GB

9.7 W/8.3 W

600 GB

3.5
inches

Issue 03 (2014-11-05)

0.38 kg
(0.84 lb)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

106

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

9 Hardware Specifications

Dimensions and Weight


Module

S2600T

S5500T

S5600T

S5800T

S6800T

Dimensions of
a controller
enclosure

l Height: 86.1 mm (3.39 in.)

l Height: 175 mm (6.89 in.)

l Width: 446 mm (17.56 in.)

l Width: 446 mm (17.56 in.)

l Depth: 582 mm (22.91 in.)

l Depth: 502 mm (19.76 in.)

Weight of a
controller
enclosure

l 30.9 kg
(68.12 lb)
with 12
SAS disks

l 30.9 kg
(68.12 lb)
with 12
SAS disks

43.6 kg (96.14 lb)

l 22.98 kg
(50.66 lb)
without
disks

l 29.9 kg
(65.91 lb)
with 24
SAS disks
l 23.9 kg
(52.70 lb)
without
disks

Issue 03 (2014-11-05)

Dimensions of
a 4 U SAS disk
enclosure

l Height: 175 mm (6.89 in.)

Weight of a 4
U SAS disk
enclosure

l 42.6 kg (93.92 lb) with 24 disks

Dimensions of
a 2 U SAS disk
enclosure

Weight of a 2
U SAS disk
enclosure

Dimensions of
a 4 U SAS
high-density
disk enclosure

l 91 kg (200.63 lb) with disks

l Width: 446 mm (17.56 in.)


l Depth: 412 mm (16.22 in.)

l 25.2 kg (55.57 lb) without disks


l Height: 86.1 mm (3.39 in.)
l Width: 446 mm (17.56 in.)
l Depth: 412 mm (16.22 in.)
l 20.9 kg (46.08 lb) with 24 disks
l 14.9 kg (32.85 lb) without disks

l 35 kg (77.16 lb) without disks

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

107

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

9 Hardware Specifications

Module

S2600T

S5500T

S5600T

Weight of a 4
U SAS highdensity disk
enclosure

l without cable management assembly

S5800T

S6800T

Height: 176.5 mm (6.95 in.)


Width: 446 mm (17.56 in.)
Depth: 790 mm (31.1 in.)
l with cable management assembly
Height: 176.5 mm (6.95 in.)
Width: 446 mm (17.56 in.)
Depth: 974 mm (38.27 in.)

Dimensions of
a data switch

l Length: 582 mm (22.91 in.)


l Width: 446 mm (17.56 in.)
l Height: 43.6 mm (1.72 in.)

Weight of a
data switch

11 kg (24.2 lb)

Electrical Specifications

Issue 03 (2014-11-05)

Data Block
Componen
t

S2600T

S5500T

S5600T

S5800T

S6800T

Power
consumption
of a
controller
enclosure

l Peak
consumptio
n: 380 W

l Peak
consumptio
n: 539 W

l Operating
consumptio
n: 350 W

l Operating
consumptio
n: 358 W

l Peak
consumpt
ion: 598
W

l Peak
consum
ption:
768 W

l No-load
consumptio
n: 280 W

l No-load
consumptio
n: 288 W

l Operatin
g
consumpt
ion: 328
W

l Operati
ng
consum
ption:
478 W

l Peak
consu
mption
: 830
W

l No-load
consumpt
ion: 318
W

l Noload
consum
ption:
450 W

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

l Operati
ng
consu
mption
: 492
W
l Noload
consu
mption
: 461
W

108

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Issue 03 (2014-11-05)

9 Hardware Specifications

Data Block
Componen
t

S2600T

S5500T

S5600T

Power
consumption
of a 2 U SAS
disk
enclosure

l Peak consumption: 307 W

Power
consumption
of a 4 U SAS
disk
enclosure

l Peak consumption: 527 W

Power
consumption
of a 4 U SAS
high-density
disk
enclosure

l Peak consumption: 1090 W

Power
consumption
of a data
switch

S5800T

S6800T

l Operating consumption: 249 W


l No-load consumption: 210 W

l Operating consumption: 441 W


l No-load consumption: 370 W

l Operating consumption: 930 W


l No-load consumption: 910 W

l Peak consumption: 99 W
l Operating consumption: 87 W
l No-load consumption: 74 W

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

109

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

9 Hardware Specifications

Data Block
Componen
t

S2600T

S5500T

S5600T

Voltage,
rated current,
rated power

l Controller
enclosure

l Controller
enclosure

l Controller enclosure

100 V to
127 V,
10 A,
650 W

100 V to
127 V,
10 A,
650 W

200 V to
240 V, 5
A, 650
W

200 V to
240 V, 5
A, 650
W

100 V to
127 V, 6
A, 480
W
200 V to
240 V, 3
A, 480
W
l Disk
enclosure
100 V to
127 V, 6
A, 480
W
200 V to
240 V, 3
A, 480
W
l Highdensity disk
enclosure
100 V to
127 V,
10 A,
800 W
(2+2
redunda
ncy)

l Disk
enclosure
100 V to
127 V, 6
A, 480
W

S5800T

S6800T

100 V to 127 V, 6 A, 480 W


200 V to 240 V, 3 A, 480 W
l Disk enclosure
100 V to 127 V, 6 A, 480 W
200 V to 240 V, 3 A, 480 W
l High-density disk enclosure
100 V to 127 V, 10 A, 800 W (2
+2 redundancy)
200 V to 240 V, 5 A, 800 W (2+2
redundancy)

200 V to
240 V, 3
A, 480
W
l Highdensity disk
enclosure
100 V to
127 V,
10 A,
800 W
(2+2
redunda
ncy)
200 V to
240 V, 5
A, 800
W (2+2
redunda
ncy)

200 V to
240 V, 5
A, 800
W (2+2

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

110

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Data Block
Componen
t

S2600T

9 Hardware Specifications

S5500T

S5600T

S5800T

S6800T

When the
output power is
170 W, the
BBU provides
power for the
storage system
for 5.5
minutes.

When the output power is 270 W, the


BBU provides power for the storage
system for 6 minutes.

redunda
ncy)
BBU

When the
output power is
100 W, the
BBU provides
power for the
storage system
for 4 minutes.

Reliability Specifications

Issue 03 (2014-11-05)

Item

S2600T

S5500T

System reliability

99.999%

Mean time between


failures (MTBF)

700,000 hours

Mean time to repair


(MTTR)

2 hours

S5600T

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

S5800T

S6800T

111

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

A How to Obtain Help

How to Obtain Help

If a tough or critical problem persists in routine maintenance or troubleshooting, contact Huawei


for technical support.
A.1 Preparations For Contacting Huawei
To better solve the problem, you need to collect troubleshooting information and make
debugging preparations before contacting Huawei.
A.2 How to Use the Document
Huawei provides guide documents shipped with the device. The guide documents can be used
to handle the common problems occurring in daily maintenance or troubleshooting.
A.3 How to Obtain Help from Website
Huawei provides users with timely and efficient technical support through the regional offices,
secondary technical support system, telephone technical support, remote technical support, and
onsite technical support.
A.4 Ways to Contact Huawei
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and
service. For any assistance, contact our local office or company headquarters.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

112

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

A How to Obtain Help

A.1 Preparations For Contacting Huawei


To better solve the problem, you need to collect troubleshooting information and make
debugging preparations before contacting Huawei.

A.1.1 Collecting Troubleshooting Information


You need to collect troubleshooting information before troubleshoot.
You need to collect the following information:
l

Name and address of the customer

Contact person and telephone number

Time when the fault occurred

Description of the fault phenomena

Device type and software version

Measures taken after the fault occurs and the related results

Troubleshooting level and required solution deadline

A.1.2 Making Debugging Preparations


When you contact Huawei for help, the technical support engineer of Huawei might assist you
to do certain operations to collect information about the fault or rectify the fault directly.
Before contacting Huawei for help, you need to prepare the boards, port modules, screwdrivers,
screws, cables for serial ports, network cables, and other required materials.

A.2 How to Use the Document


Huawei provides guide documents shipped with the device. The guide documents can be used
to handle the common problems occurring in daily maintenance or troubleshooting.
To better solve the problems, use the documents before you contact Huawei for technical support.

A.3 How to Obtain Help from Website


Huawei provides users with timely and efficient technical support through the regional offices,
secondary technical support system, telephone technical support, remote technical support, and
onsite technical support.
Contents of the Huawei technical support system are as follows:
l

Huawei headquarters technical support department

Regional office technical support center

Customer service center

Technical support website: http://support.huawei.com/enterprise/

You can query how to contact the regional offices at http://support.huawei.com/enterprise/.


Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

113

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

A How to Obtain Help

A.4 Ways to Contact Huawei


Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and
service. For any assistance, contact our local office or company headquarters.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of
China
Website: http://support.huawei.com/enterprise/

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

114

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

B Glossary

Glossary

A
The module that transfers the external AC power supply into the power
AC power module supply for internal use.
Application
server

A service processing node (a computer device) in the network.


Application programs of data services are run on the application server.

Asynchronous
remote
replication

A kind of remote replication. When the data on the primary site is


updated, the data does not need to be updated on the mirroring site
synchronously to finish the update. In this way, performance is not
reduced due to data mirroring.

Issue 03 (2014-11-05)

Backup

A periodic operation performed on the data stored in the database for


the purposes of database recovery in case that the database is faulty. The
backup also refers to data synchronization between active and standby
boards.

Bandwidth

A range of transmission frequencies that a transmission line or channel


can carry in a network. In fact, it is the difference between the highest
and lowest frequencies the transmission line or channel. The greater the
bandwidth, the faster the data transfer rate.

Baud rate

The number of times per second the signal can change on a transmission
line. Commonly, the transmission line uses only two signal states,
making the baud rate equal to the number of bits per second that can be
transferred. The underlying transmission technique may use some of the
bandwidth, so it may not be the case that user data transfers at the line's
specified bit rate.

Bit error

A computer that is connected to the serial port or management network


port of the storage system for maintenance.

Bit error rate

The percentage of bits that have errors relative to the total number of
bits received in a transmission.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

115

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

B Glossary

Bonding

Bonding can bind multiple independent physical network ports into a


logical port, which ensures the high availability of server network
connections and improving network performance.

Boundary scan

A test methodology that uses shift registers in the output connections of


integrated circuits. One IC often is connected to the next. A data pattern
is passed through the chain and the observed returned data stream
affected by the circuit conditions gives an indication of any faults
present. The system is defined under IEEE standard 1149.1 and is also
often known as JTAG (Joint Test Action Group).

Browser/Server

An architecture that defines the roles of browser and server, where the
browser is the service request party and the server is the service provider.

Issue 03 (2014-11-05)

Cache hit ratio

The ratio of directly accessed I/O from Cache to all the I/O operation
during the read operation.

Cache prefetch
strategy

According to the operation in which data has been read or is being read,
the required data is read from a disk into the cache in advance.

Captive Screw

After the screw is loosened, screw caps and bolts are not disconnected
from the main body.

Cascading

Connect the storage system to more disk enclosures through connection


cables, thus expanding the capacity of the storage system.

CHAP

A method to periodically verify the identity of the peer using a 3-way


handshake. During the establishment of a link, the authenticator sends
a "challenge" message to the peer. The peer responds with a value
calculated using a "one-way hash" function. The authenticator checks
the response against its own calculation of the expected hash value. If
the values match, the authentication is acknowledged. CHAP provides
protection against playback attack.

Clone

A snapshot technology. The source data is completely copied to


generate a data duplicate; therefore the duplicate needs the storage space
as the same size as the source data. It is also called clone. In the VIS
system, it is also called third-mirror break-off snapshot.

Cluster

A mechanism adopted to improve the system performance. Several


devices of the same type form a cluster. The exterior of a cluster is some
like a kind of equipment. In the interior of a cluster, the nodes share the
load.

Coffer

A technology for ensuring data security and integrity in a storage


system. It is used to store the mission-critical data of the system.

Coffer disk

Disks that build up the coffer.

Command device

A special LUN through which the host can send inband commands to
storage devices.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

116

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

B Glossary

Constant prefetch A cache prefetch strategy. The size of the data to be prefetched is the
size as set. This strategy applies to the applications that require reading
data of a fixed size in a certain order. An example is the streaming media
demanded by multiple subscribers who use the same bit rate.
Controller

The core module that processes services in a storage system. It contains


physical components such as system-level CPUs and memory.

Controller
enclosure

An enclosure that accommodates controllers and provides storage


services. It is the core component of a storage system, and generally
consists of components such as controllers, power supplies, and fans.

Copyback

The process of copying the data from the hot spare disk back to the
previous disk when the faulty member disk is restored or replaced by a
new one.

Copying

A state of pair. The state indicates that the source LUN data is being
synchronized to the target LUN.

Issue 03 (2014-11-05)

Data flow

A process that involves processing the data extracted from the source
system, such as filtering, integration, calculation, and summary, finding
and solving data inconsistency, and deleting invalid data so that the
processed data meets the requirements of the destination system for the
input data.

Data migration

It is the process to cleanse and transform history data, and then load
them to the new system.

Data source

A system, database, or file that can make BOs persistent. A data source
can be a database instance or a database user.

Data switch

A data switch used for interconnections between controllers.

Dirty data

The data that is stored temporarily on cache and has not been written
onto disks.

Disaster recovery

A system deployment solution aiming at reducing loss in disasters. A


set of disaster recovery system that is the same as the production system
is deployed as a backup to store the production data when a fault occurs
in the production system. The applications are switched over to the
disaster recovery system before the production system recovers. After
the production system recovers, the applications are switched back to
the production system.

Disk array

A set of disks from one or more commonly accessible disk subsystem.


These disks are combined and controlled by the control software. The
control software provides the storage capacity of these disks for hosts
as one or more virtual disks.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

117

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

B Glossary

Disk Domain

A combination of disks. A disk domain consists of the same type or


different types of disks. Disk domains are isolated from each other.
Therefore, services carried by different disk domains do not affect each
other in terms of performance and faults (if any).

Disk location

Locate a hard disk, that is, determine the enclosure number and slot
number of the hard disk in the storage system.

Disk enclosure

It consists of the following parts in redundancy: expansion module, hard


disk, power module, and fan module. System capacity can be expanded
by cascading multiple disk enclosures.

Disk utilization

The percentage of used capacity in the total available capacity.

E
eDevLUN
(external device
LUN)

Logic space created by third-party storage systems.

Engine

Two controllers in one enclosure are called Engine.

Expansion

Connecting a storage system to more disk enclosures through


connection cables, thus expanding the capacity of the storage system.

Expander module

A component used for expanding.

Issue 03 (2014-11-05)

Failover

The automatic substitution of a functionally equivalent system


component for a failed one. The term failover is most often applied to
intelligent controllers connected to the same storage devices and host
computers. If one of the controllers fails, failover occurs, and the
survivor takes over its I/O load.

Field replaceable
unit

A unit that can function as a circuit board, part, or component of an


electronic device. It can be quickly and easily removed from a personal
computer or other electronic devices. If an FRU becomes faulty, users
can replace it with a new one instead of sending the entire product or
system for maintenance.

File Engine

The component in a unified storage systems that provides file-level


service.

Firmware

The programmable software part in a hardware component. A firmware


is a part of hardware, but is scalable as software.

Front-end host
port

The port that connects the controller enclosure to the service side and
transfers service data. There are three types of front-end host ports: SAS,
FC, and iSCSI.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

118

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

B Glossary

G
Gateway

The entrance node on another network.

Global system for


mobile
communications

The second-generation mobile networking standard defined by


European Telecommunications Standards Institute (ETSI). It is aimed
at designing a standard for global mobile phone networks. The standard
allows a subscriber to use a phone globally. GSM consists of three main
parts: mobile switching subsystem (MSS), base station subsystem
(BSS), and mobile station (MS).

H
Hard disk

A non-volatile storage device that stores digitally encoded data on


rapidly rotating platters with magnetic surfaces. Hard disks generally
offer more storage and quicker access to data than floppy disks do.

Hard disk tray

The tray that bears the hard disk.

Heartbeat

Heartbeats are the packets, requiring no acknowledgement, transmitted


between two devices. The device can judge the validity status of the
peer device. Heartbeat supports node communication, fault diagnosis,
and event triggering.

Hit ratio

The ratio of directly accessed I/Os from cache to all I/Os.

Hot swap

In a running system, inserting or removing a blade does not affect


normal running of the system.

Issue 03 (2014-11-05)

I/O

Data movement process between memory and peripheral devices in the


computer system. I/O is a collective name, indicating the operations
reading data into the memory and writing data to other places from
computer memory.

Inband
management

Inband management means that the management control information of


the network and the carrier service information of the user network are
transferred through the same logical channel. Inband management
enables users to manage storage arrays through commands.
Management commands are sent through service channels, that is, I/O
write and read channels. The advantages of inband management include
high speed, stable transfer, and no additional management network ports
required.

Initiator

A system component that can initiate an I/O operation on an I/O bus or


on a network.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

119

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

B Glossary

Intelligent
prefetch

A cache prefetch strategy. The system software calculates a proper size


of prefetched data. This strategy applies to a read application involving
a single bit stream or to the situations where you do not know whether
the data is read in a certain order. An example is reading or writing a
file.

Interface module

interface module connects various types of front-end host port, such as


the front-end host ports of SAS, FC and iSCSI.
The interface module can be configured with one type of the following
host ports or expansion ports: 10Gb iSCSI, 8Gb FC, and iSCSI host
ports, or 4Gb FC and 6Gb SAS expansion ports.

L
Load balance

A method of adjusting the system, application components and data to


averagely distribute the applied I/O or computing requests for physical
resources of the system.

Logical unit

The entity is located inside the SCSI object, and can execute I/O
commands. After a SCSI I/O command is sent to an object, the logic
unit inside the object executes this command. Usually, each SCSI
physical disk has one logic unit. A tape drive and array controller may
have multiple logic units, which process different I/O commands. Each
logic unit inside an array controller corresponds to a virtual disk.

Logical unit
number

The SCSI identifier of the internal logical unit of a target.

LUN format

The process of writing 0 bits in the data area on the logical drive and
generating related parity bits so that the logical drive can be in the ready
state.

LUN mapping

The storage system maps LUNs to ASs so that the ASs can access the
storage reorganization.

LUN migration

A method for the data in the LUN to migrate between different physical
storage space while ensuring data integrity and uninterrupted operation
host services.

LUN copy

The function of copying the original LUN data to one or multiple target
LUNs.

Issue 03 (2014-11-05)

Maintenance
terminal

The computer that is connected through a serial port or management


network port and maintains the storage system.

Management
network

An entity that provides a means to transmit and process the information


related to network management.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

120

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Management
network port

B Glossary

The network port on the controller enclosure that is connected to the


maintenance terminal. It is provided for the remote maintenance
terminal.

N
Node

A managed device in the network. For a device with a single frame, one
node stands for one device. For a device with multiple frames, one node
stands for one frame of the device.

O
Out-of-band
management

A management mode used during out-of-band networking. In the outof-band management mode, the management and control information
of the network and the bearer service information of the user network
are transmitted through different logical channels.

Original LUN

The LUN where the original data of the copied LUNs is located.

Owning
controller

For a LUN, the user configures the owing controller, that is, specified
the created LUN to a certain controller. When the owning controller of
the LUN is invalid, another controller manages the LUN automatically.
When the owning controller of the LUN is restored, the original
controller manages the LUN again.

P
Power failure
protection

When the external power failure occurs, the AC PEM depends on the
battery for power supply, which ensures the integrity of the dirty data
in cache.

Pre-copy

When the system monitors that a member disk in a RAID group is to


fail, the system copies the data on the disk to a hot spare disk in advance.
This technology is called pre-copy.

Primary storage
controller

The controller that plays a leading role in controlling the management


is the primary storage controller. It can perform relevant management
operations on the controller enclosure.

Primary/
Secondary
switchover

A procedure during which the two controllers of the storage system


change their master/slave states.

Prior controller

For the application server LUN, prior controller means that the working
controller is the owner controller of the corresponding array LUN.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

121

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

B Glossary

RAID level

The application of different redundant types to a logical drive. A RAID


level improves the fault tolerance or performance of the logical drive
but reduces the available capacity of the logical drive. You must specify
a RAID level for each logical drive.

Reconstruction

A function of the storage system. It refers to the process of restoring the


data saved in the faulty member disk in a storage pool.

Redundancy

The scheme to add more than one channels, elements or parts that have
the same functions with the counterparts in the system or device at a
critical place. When a fault occurs, the system or device can work well,
and the reliability is then improved.

Remote
replication

A core technology for disaster recovery and a foundation that


implements remote data synchronization and disaster recovery. This
technology remotely maintains a set of data mirror through the remote
data connection function of the storage devices that are separated in
different places. Even when a disaster occurs, the data backup on the
remote storage device is not affected. Remote replication can be divided
into synchronous remote replication and asynchronous remote
replication by whether the host that requires mirrors needs the
confirmation information of the remote replication site.

Reverse
synchronizing

The process of restoring data from the redundancy machine (RM) when
the services of the production machine (PM) are recovering.

Route

The path that network traffic takes from its source to its destination. In
a TCP/IP network, each IP packet is routed independently. Routes can
change dynamically.

Issue 03 (2014-11-05)

Script

A collection of data statements used to perform an operation.

Secondary
controller

(1) A controller that backs up service and management data of the


primary controller in a clustered system. When the primary controller
fails, the secondary controller is upgraded to the primary controller and
takes over the management and services of the controller enclosure. (2)
A controller that backs up the management data of the primary controller
in a block-level array. When the primary controller fails, the secondary
controller is upgraded to the primary controller and takes over the
management of the system.

Serial port

An input/output location (channel) that sends and receives data to and


from a computer's CPU or a communications device one bit at a time.
Serial ports are used for serial data communication and as interfaces
with some peripheral devices, such as mice and printers.

Service data

Data which is saved in data disk. Service data is the data source for
computing check data in parity disk.

Service network
port

The network port that is used to store services.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

122

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Issue 03 (2014-11-05)

B Glossary

SFP optical
transceiver

A component that can make data conversion between optical signals


and electrical signals and that can receive and transfer data.

Simple network
management
protocol

A network management protocol of TCP/IP. It enables remote users to


view and modify the management information of a network element.
This protocol ensures the transmission of management information
between any two points. The polling mechanism is adopted to provide
basic function sets. According to SNMP, agents, which can be hardware
as well as software, can monitor the activities of various devices on the
network and report these activities to the network console workstation.
Control information about each device is maintained by a management
information block.

Single point
failure

A type of failure. Data transmission over a network is stopped and


cannot be recovered automatically if a single point failure occurs. The
point can be an interface, a board, a device, or a link.

Small computer
system interface

A set of standards for physically connecting and transferring data


between computers and peripheral devices. SCSI is most commonly
used for hard disks and tape drives, but it can connect a wide range of
other devices, including scanners, and optical drive.

SmartTenancy

A feature of Huawei storage system. With SmartTenancy, multiple


virtual storage systems can be created in one physical storage system,
which allows tenants to share the same storage system hardware
resource without affecting data security and privacy of each other. This
feature achieves more flexible, easy-to-manage and low-cost shared
storage in a multi-protocol unified storage architecture.

Snapshot

A data backup technology through which a fully usable copy of a data


object can be quickly generated. The duplicate contains the image of
the data object at a point in time.

Snapshot copy

A copy of the snapshot LUN, which is also a snapshot LUN.

Storage system

An integrated system. It consists of the following parts: controller,


storage array, host bus adaptor, physical connection between storage
units, and all control software.

Storage unit

An abstract definition of backup storage media for storing backup data.


The storage unit is connected with actual storage media, used to back
up data.

Streaming media

A transmission mode in which data is consumed (read, listened to, or


watched) while it is being sent.

Stripe

The set of strips at corresponding locations of each member extent of a


disk array which uses striped data mapping. The strips in a stripe are
associated with each other in a way (e.g., relative extent block
addresses) that allows membership in the stripe to be quickly and
uniquely determined by a computational algorithm. Parity RAID uses
stripes to map virtual disk block addresses to member extent block
addresses.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

123

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

B Glossary

Subnet

A type of smaller networks that form a larger network according to a


rule, for example, according to different districts. This facilitates the
management of the large network.

Subnet mask

The technique used by the IP protocol to determine which network


segment packets are destined for. The subnet mask is a binary pattern
that is stored in the device and is matched with the IP address.

Synchronous
remote
replication

A kind of remote replication. When the data on the primary site is


updated, the data must be synchronously updated on the mirroring site
before the update is complete. In this way, the data that is stored on both
the primary and mirroring sites can be synchronized.

T
Target

A system component that can receive SCSI I/O operation commands.

Target LUN

The target for LUN copy.

Thin provisioning

A mechanism that offers on-demand allocation of storage space.

Thin LUN

The thin LUN is a logic disk that can be accessed by hosts. The thin
LUN dynamically allocates storage resources from the thin pool
according to the actual capacity requirements of users.

Timing Snapshot

To create snapshots periodically to continuously protect data.

Topology

The logical layout where computer systems and network components


are interconnected with one another. The topological structure gives the
interconnection relationship among the components from the viewpoint
of communication, but the topological structure does not specify the
exact locations of components and the interconnection mode.

Trap

A type of SNMP message that indicates the occurrence of an event. This


type of message is transmitted to the received through UDP. The
transmission process is not completely reliable.

U
User datagram
protocol

A TCP/IP standard protocol that allows an application program on one


device to send a datagram to an application program on another. User
Datagram Protocol (UDP) uses IP to deliver datagram. UDP provides
application programs with the unreliable connectionless packet delivery
service. There is a possibility that UDP messages will be lost,
duplicated, delayed, or delivered out of order. The destination device
does not confirm whether a data packet is received.

User interface

The space in which users interact with a machine.

Issue 03 (2014-11-05)

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

124

OceanStor S2600T&S5500T&S5600T&S5800T&S6800T
Storage System
Hardware Description

Variable prefetch

B Glossary

A cache prefetch strategy. The size of the data to be prefetched is the


multiple for prefetching multiplied by the length of a read command.
This strategy applies to the applications that require reading data of
variable size in a certain order or to the situations where multiple
subscribers read data concurrently but no fixed prefetch size can be set,
because the amount of pre-read data cannot be judged. An example is
the streaming media demanded by multiple subscribers who use
different bit rates.

vStore

A property of SmartTenancy. In Huawei SmartTenancy, a tenant is


called a vStore, which represents a virtual storage system.

W
Working
controller

The controller used by the array LUN to read and write a disk.

Write back

A caching technology in which the completion of a write request is


signaled as soon as the data is in cache, and actual writing to non-volatile
media occurs at a later time. Write back includes an inherent risk that
an application will take some action predicated on the write completion
signal, and a system failure before the data is written to non-volatile
media will cause media contents to be inconsistent with that subsequent
action. For this reason, good write back implementations include
mechanisms to preserve cache contents across system failures
(including power failures) and to flush the cache at system restart time.

Write through

A caching technology in which the completion of a write request is not


signaled until data is safely stored on non-volatile media. Write
performance with the write through technology is approximately that of
a non-cached system, but if the data written is also held in cache,
subsequent read performance may be dramatically improved.

Z
Zone

Issue 03 (2014-11-05)

In the fiber channel, a collection of the N_Port or the NL_Port which


can communicate with each other in the optical network. Only the
N_Port or the NL_Port in the same partition can communicate with each
other through the optical network.

Huawei Proprietary and Confidential


Copyright Huawei Technologies Co., Ltd.

125

You might also like