You are on page 1of 84

5/2014

Marine and Offshore Cables

Contents
Helkama a true specialist
in marine cables ......................2
Approvals..................................3
0,6/1kV cables
LKM-HF.....................................4
LKMM-HF .................................8
LKSM-HF.................................10
LKMSM-HF .............................14
LKAM-HF.................................16
LKEM-HF.................................18
EMC cables
LKSM-EMC..............................20
LKSM-EMC-FRHF....................24
RFE-EMC.................................28
RFE-EMC(i) .............................30
1,8/3kV cables
LKSM-VFD ..............................32
0,6/1kV FR cables
LKM-FRHF...............................34
LKSM-FRHF ............................38
LKAM-FRHF ............................42
250V cables
LKM-HF ..................................44
LKSM-HF.................................46
LKAM-HF ................................48
RFE-HF ....................................50
RFE-HF (i) ...............................52
RFA-HF ....................................54
RFA-HF (i) ...............................56
250V FR cables
LKM-FRHF ..............................58
LKSM-FRHF ...........................60
LKAM-FRHF ...........................62
RFE-FRHF................................64
RFE-FRHF (i) ...........................66
RFA-FRHF................................68
RFA-FRHF (i) ...........................70
Optical fibre cables
FXMSU ....................................72
FXMMS ...................................74
Cabled optical fibres
characteristics .........................76
Technical information
General information.................78
Bending radius ........................79
Diameter tolerance ..................79
Core identification ...................79
Current rating..........................80
Short circuit current ................81
Short time duty .......................82
Voltage drop............................83
Subject to change without prior notice.
See latest updates on our webpage
www.helkamabica.com

HELKAMA a true specialist in marine cables


Helkama is specializing in development and production of
marine and offshore cables. Our experience in this field goes
back fifty years. Our high technical quality has been achieved
by continuous development work supported by our clients.
In this catalogue we proudly present our most comprehensive
range of marine cables.
We have chosen to produce only halogen-free cables. They
remarkably improve the fire safety of the ships by not emitting
toxic burning fumes or thick smoke. In addition no corrosive
gases damaging the ship and its equipment are emitted in
case of a fire. Using the latest technology we have been able
to reduce cable weight and size to a minimum and still
maintain quality as well as enabling easy and fast installation.
The halogen free range of cables includes both flame-retardant
(IEC 60332-3) and fire resistant (IEC 60331-series) cables.
Helkama marine cables are approved by all major classification
societies.
As a specialized and independent
company, focusing on service, we have
been able to grow steadily by quickly
responding to our customers needs.
Our short delivery times, backed up by
extensive stocks, enable us to deliver
punctually and keep our clients satisfied.
This remains our goal for the future, too.

Marine cable factory in


Kaarina, Finland.

3
TYPE APPROVALS

Type Approval Certificates for factories in Finland and China

www.helkamabica.com

Please check updated approval situation on www.helkamabica.com

Marine cable factory in


Shanghai, China.

0,6/1kV CABLES

LKM-HF

Unarmoured power and


control cable 0,6/1kV

DESIGN:

STANDARDS:
IEC 60092-353, design

1. Conductor
- stranded copper conductor 1,0-10mm2 IEC 60228, class 2
- stranded copper conductor 16-300mm2 IEC 60228, class 5 (Flex)
- tinned stranded copper conductor on request
Flameretardant
2. Insulation
Fire- XLPE plastic
IEC 60092-351
resistant

5/2014

3. Bedding
- separator tape
4. Sheath
- polyolefine plastic, SHF1
IEC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request

Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
Main characteristics
Rated voltage

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

Part number
Normal
G-type

28396
27000
27002
27004
27006
27009
27011
27013
27015
27017
27019
27021
27023
27025
27027
27029

25672
25689
25704
25706
25708
26072
26074
26076
26078
26080
26082
26085
26086
26088
26090

1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
3x185 Flex
3x240 Flex

Nominal
outer
diameter
mm
5,0
5,5
5,5
6,5
7,0
8,0
9,0
11,5
12,5
14,5
17,0
19,5
21,5
24,5
27,0
30,5
33,0
7,5
8,5
9,5
10,5
12,0
14,0
16,5
20,5
23,0
27,5
31,5
8,0
9,0
10,0
11,5
13,0
15,0
17,5
22,0
25,0
29,5
34,5
40,0
44,5
50,5
57,0
64,5

Approximate
weight kg/km
35
40
55
70
95
140
185
290
385
540
750
975
1225
1545
1880
2495
3055
65
80
115
155
240
360
490
755
1035
1455
1995
80
100
145
200
310
465
625
970
1325
1880
2615
3455
4365
5485
6800
9045

Current
Rating A
at +45C
18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
15
20
26
34
44
61
80
105
130
167
204
13
16
21
28
36
50
66
86
107
137
168
199
232
267
300
355

Min. bending
radius fixed
installation
mm
20
25
25
30
30
35
40
50
50
60
70
80
90
100
165
185
200
30
35
40
45
50
60
70
85
95
170
190
35
40
45
50
55
65
75
90
100
180
210
240
270
305
345
390

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Table continues on next page

5/2014

25636
25638
25640
25642
25644
25647
25649
25651
25653
25655
25657
25659
25661
25663
25665
26047
25581
25670
25686
25702
25701
25717
26054
26055
26056
26057
26058
25582
25671
25688
25703
25705
25707
26071
26073
26075
26077
26079
26081
26083
26084
26087
26089

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKM-HF 0,6/1kV

5/2014

0,6/1kV CABLES

LKM-HF 0,6/1kV
Part number
Normal
G-type
25583
25673
25690
25725
25727
25729
26101
26103
26105
26107
26109
26111
26113
25584
25676
25692
25864
25866
25868
26131
26133
26135
26137
26139
25585
25586
25587
25588
25589
25590
25592
25593
25597
25595

25674
25691
25726
25728
25730
26102
26104
26106
26108
26110
26112
26114

25677
25693
25865
25867
25869
26132
26134
26136
26138
26140

Number of
conductors &
cross-section
n x mm2
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
5x35 Flex
5x50 Flex
5x70 Flex
7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
30x1,0
37x1,0

Nominal
outer
diameter
mm
8,5
10,0
11,0
12,5
14,0
16,5
19,5
24,5
27,5
33,0
38,0
44,5
49,5
9,5
11,0
12,0
13,5
15,5
18,5
21,5
27,5
30,5
37,0
42,5
10,5
13,5
13,5
14,5
15,5
16,0
19,0
19,5
20,0
22,0

Approximate
weight kg/km
95
135
180
260
385
585
800
1250
1695
2420
3350
4465
5590
125
160
220
320
475
720
970
1545
2100
2980
4175
155
225
250
280
325
365
465
510
555
680

Current
Rating A
at +45C
13
16
21
28
36
50
66
86
107
137
168
199
232
10
13
17
23
30
42
55
71
89
114
139
9
8
8
7
7
7
6
6
5
5

Min. bending
radius fixed
installation
mm
35
40
45
55
60
70
80
100
170
200
230
270
300
40
45
50
55
65
75
90
165
185
225
260
45
55
55
60
65
65
80
80
85
90

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Table continues on next page

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

Part number
Normal
G-type
25679
25668
25681
25992
25990
25683
25876
25685
25687
25695
25994
25874
25996
25998
25872
25878
26142

7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5

Nominal
outer
diameter
mm
11,5
15,0
15,5
16,5
17,0
18,5
22,0
22,0
25,0
13,5
17,0
17,5
18,5
19,5
20,5
24,5
25,0

Approximate
weight kg/km
200
290
335
380
430
495
635
700
920
285
410
465
535
605
690
900
990

Current
Rating A
at +45C
12
11
10
10
9
9
8
8
7
16
14
13
13
12
11
10
10

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Min. bending
radius fixed
installation
mm
50
60
65
70
70
75
90
90
100
55
70
70
75
80
85
100
155

5/2014

25678
25667
25680
25991
25989
25682
25875
25684
25675
25694
25993
25696
25995
25997
25873
25877
26141

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKM-HF 0,6/1kV

0,6/1kV CABLES

LKMM-HF

Unarmoured power cable


with extruded filler 0,6/1kV

DESIGN:

STANDARDS:
IEC 60092-353, design

1. Conductor
- stranded copper conductor 1,510mm2 IEC 60228, class 2
- stranded copper conductor 16150mm2 IEC 60228, class 5
- tinned stranded copper conductor on request

5/2014

2. Insulation
- XLPE plastic

IEC 60092-351

3. Bedding
- extruded filler
4. Sheath
- polyolefine plastic, SHF1
IEC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
Main characteristics
Rated voltage

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

27566
27570
27574
27578
27582
27587
27591
27595
27599
27603
27607
27611
27615
27630
27634
27638
27642
27646
27651
27655
27659
27663
27667
27694
27698
27702
27706
27710
27715
27719

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
2x70
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
5x1,5
5x2,5
5x4
5x6
5x10
5x16
5x25

9,0
10,0
11,0
12,5
14,5
18,5
23,0
25,5
30,0
34,0
9,5
10,5
12,0
13,5
15,5
20,0
24,5
27,0
32,0
37,0
42,5
47,0
53,5
10,5
11,5
13,0
14,5
17,5
21,5
27,0
30,0
35,5
40,5
11,5
12,5
14,5
16,5
19,0
24,0
29,5

110
155
205
285
420
630
970
1340
1855
2510
130
180
245
350
515
770
1170
1600
2220
3090
4055
5070
6425
165
215
305
420
635
935
1440
1955
2735
3790
195
255
360
515
770
1145
1750

20
26
34
44
61
80
105
130
167
204
16
21
28
36
50
66
86
107
137
168
199
232
267
16
21
28
36
50
66
86
107
137
168
13
17
23
30
42
55
71

35
40
45
50
60
75
90
155
180
205
35
45
45
55
60
80
100
160
190
220
255
285
320
40
45
50
60
70
85
160
180
210
245
45
50
55
60
75
95
175

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

27532
27534
27536
27538
27540
27543
27545
27547
27549
27551
27564
27568
27572
27576
27580
27585
27589
27593
27597
27601
27605
27609
27613
27628
27632
27636
27640
27644
27649
27653
27657
27661
27665
27692
27696
27700
27704
27708
27713
27717

Nominal
outer
diameter
mm

5/2009

Part number
Normal
G-type

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKMM-HF 0,6/1kV

0,6/1kV CABLES

10

LKSM-HF

Armoured power and


control cable 0,6/1kV

5/2014

DESIGN:

STANDARDS:
IEC 60092-353, design

1. Conductor
- stranded copper conductor 1,0-10mm2IEC 60228, class 2
- stranded copper conductor 16-300mm2IEC 60228, class 5 (Flex)
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Bedding
- filler tape
4. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
5. Sheath
- polyolefine plastic, SHF1
IEC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
Main characteristics
Rated voltage
Maximum conductor
temperature

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

11

Part number
Normal
G-type

Number of
conductors &
cross-section
n x mm2

27052
27054
27056

1x1,0
1x1,5
1x2,5
1x4
1x6
1x10

26237
26238
26239
26240
26241
26242
26243
26244
26245
26246
26247

27059
27061
27063
27065
27067
27069
27071
27073
27075
27077
27079

1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex

25956
25770
25785
25801
25803
25805

2x1,0
2x1,5
2x2,5
2x4
2x6
2x10

26254
26255
26256
26257
26258

26259
25957

25772
25786
25802
25804
25806
26271
26273
26275
26277
26279
26281
26283
26285
26287

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

3,0
3,0
3,1
3,1
3,1
3,5

6,0
6,5
7,0
7,5
8,0
9,5

70
75
90
105
130
190

18
23
30
40
52
72

40
40
45
45
50
60

4,1
4,9
5,5
8,7
11,4
11,5
14,5
14,7
15,2
18,2
18,7

10,5
13,0
14,0
17,0
19,0
21,5
23,5
26,5
29,0
32,5
35,5

240
360
460
650
885
1115
1405
1720
2065
2715
3300

94
123
153
196
240
284
331
381
429
507
582

65
80
90
105
115
130
145
160
180
200
215

3,6
3,8
4,3
4,9
5,4
8,7

9,0
9,5
10,5
12,0
13,0
15,5

110
130
160
210
315
480

15
20
26
34
44
61

55
60
65
75
80
95

2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex

10,0
14,5
14,7
18,1
18,7

18,0
23,0
25,5
29,5
34,0

625
985
1240
1700
2270

80
105
130
167
204

110
140
155
180
205

2x95 Flex
3x1,0

22,2
3,7

39,0
9,5

2965
130

241
13

235
60

25773
25787
25880
25882
25884
26272
26274
26276
26278
26280
26282
26284
26286
26288

3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex
3x150 Flex
3x185 Flex

4,1
4,6
5,2
5,8
9,3
10,7
14,6
15,0
18,3
22,0
22,8
37,8
39,3
47,9

10,0
11,0
12,5
14,0
16,5
19,0
24,5
27,0
32,0
36,5
42,0
47,0
53,0
59,5

155
195
260
370
570
750
1165
1505
2100
2850
3685
4745
5885
7265

16
21
28
36
50
66
86
107
137
168
199
232
267
300

65
70
80
85
100
115
150
165
195
220
255
285
320
360

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Table continues on next page

5/2014

25955
25736
25738
25740
25742
25744

Crosssection of
armour
mm2

0,6/1kV CABLES

LKSM-HF 0,6/1kV

5/2014

0,6/1kV CABLES

12

LKSM-HF 0,6/1kV
Part number
Normal
G-type

Number of
conductors &
cross-section
n x mm2

Crosssection of
armour
mm2

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

25958
25774
25788
25830
25832
25834

25775
25789
25831
25833
25835

4x1,0
4x1,5
4x2,5
4x4
4x6
4x10

4,1
4,5
5,0
5,8
8,8
10,3

10,0
11,0
12,5
13,5
15,5
18,0

150
180
240
320
475
695

13
16
21
28
36
50

65
70
75
85
95
110

26301
26303
26305
26307
26309
26311
26313

26302
26304
26306
26308
26310
26312
26314

4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
4x120 Flex
4x150 Flex

11,9
14,8
18,1
19,5
22,6
37,8
39,3
48,2

21,0
27,0
29,5
35,5
40,0
47,0
52,0
59,0

945
1440
1900
2635
3590
4850
6010
7565

66
86
107
137
168
199
232
267

130
165
180
215
245
285
315
355

25959
25776
25790
26011
26013
26015

25777
25791
26012
26014
26016

5x1,0
5x1,5
5x2,5
5x4
5x6
5x10

4,5
5,0
5,6
8,6
9,7
11,5

10,5
12,0
13,5
15,0
17,0
20,0

175
220
285
410
565
830

10
13
17
23
30
42

65
75
80
95
105
120

26331
26333

26332
26334

5x16 Flex
5x25 Flex

13,2
18,1

23,0
29,5

1070
1655

55
71

140
180

25960
25961
25962
25963
25964
25965
25977
25978
25981

7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
37x1,0

4,9
8,7
9,0
9,4
11,4
11,4
12,5
12,8
14,4

11,5
15,0
15,0
16,0
17,0
17,5
20,5
21,0
23,5

215
320
350
385
445
490
610
655
840

9
8
8
7
7
7
6
6
5

75
90
95
100
105
110
125
130
145

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Table continues on next page

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

13

Part number
Normal
G-type
25779
26026
25846
26028
26029
25781
25829
25847
25848
25793
26034
25795
26036
26038
25797
25799
25769

Crosssection of
armour
mm2

7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5

5,4
9,6
9,9
10,5
11,5
11,7
13,9
14,1
16,0
8,5
11,5
11,5
11,8
12,5
13,2
15,7
16,1

Nominal
outer
diameter
mm
13,0
16,5
17,0
18,0
19,0
19,5
23,5
24,0
26,5
15,0
18,5
19,0
20,5
21,5
22,5
26,0
27,0

Approximate
weight kg/km
265
390
440
490
545
610
780
845
1085
380
535
595
680
760
855
1080
1175

Current
Rating A
at +45C
12
11
10
10
9
9
8
8
7
16
14
13
13
12
11
10
10

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G16
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Min. bending
radius fixed
installation
mm
80
100
105
110
115
120
140
145
160
90
115
115
125
130
135
160
165

5/2014

25778
26025
25780
26027
26030
25782
25828
25783
25784
25792
26033
25794
26035
26037
25796
25798
25768

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKSM-HF 0,6/1kV

0,6/1kV CABLES

14

LKMSM-HF

5/2014

DESIGN:

Armoured power cable


with extruded filler 0,6/1kV

STANDARDS:
IEC 60092-353, design

1. Conductor
- stranded copper conductor 1,510mm2 IEC 60228, class 2
- stranded copper conductor 16150mm2 IEC 60228, class 5
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Bedding
- extruded filler
4. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid and galvanized steel wire braid
on request
5. Sheath
- polyolefine plastic, SHF1
IEC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
Main characteristics
Rated voltage
Maximum conductor
temperature

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)
+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

15

Part number
Normal
G-type

27266
27270
27274
27278
27282
27287
27291
27295
27299
27303
27307
27311
27315
27330
27334
27338
27342
27346
27351
27355
27359
27363
27367
27371
27375
27394
27398
27402
27406
27410
27415
27419

2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
5x1,5
5x2,5
5x4
5x6
5x10
5x16
5x25

Crosssection of
armour
mm2
4,9
5,4
6,0
9,1
10,7
12,4
15,4
17,1
20,2
5,1
5,7
6,4
9,7
11,4
13,2
16,4
18,2
21,9
25,4
40,6
44,8
51,7
5,6
6,3
9,5
10,6
12,5
14,5
18,2
20,2
24,1
45,7
45,0
51,2
6,1
9,2
10,4
11,8
13,8
16,0
20,1

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

11,5
12,5
14,0
15,5
17,5
20,0
24,5
27,0
31,0
12,0
13,5
14,5
16,0
18,5
21,0
26,0
28,5
33,5
38,5
45,0
49,0
55,5
13,0
14,0
16,0
17,5
20,0
23,0
28,5
31,5
37,0
43,0
49,0
55,0
14,0
15,5
17,0
19,0
22,0
25,5
31,0

195
230
290
425
580
740
1085
1400
1895
220
275
345
495
685
885
1320
1710
2345
3200
4270
5235
6610
260
320
430
590
830
1085
1605
2105
2875
4120
5245
6575
300
395
510
690
985
1300
1925

20
26
34
44
61
80
105
130
167
16
21
28
36
50
66
86
107
137
168
199
232
267
16
21
28
36
50
66
86
107
137
168
199
232
13
17
23
30
42
55
71

70
75
85
90
105
120
145
160
190
75
80
85
95
110
125
155
170
200
230
270
295
335
80
85
95
105
120
140
170
190
220
260
295
330
85
95
105
115
130
152
185

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

27232
27234
27236
27238
27240
27243
27245
27247
27249
27264
27268
27272
27276
27280
27285
27289
27293
27297
27301
27305
27309
27313
27328
27332
27336
27340
27344
27349
27353
27357
27361
27365
27369
27373
27392
27396
27400
27404
27408
27413
27417

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKMSM-HF 0,6/1kV

0,6/1kV CABLES

16

LKAM-HF

Screened power and control cable


0,6/1kV

DESIGN:

STANDARDS:
IEC 60092-353, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request

5/2014

2. Insulation
- XLPE plastic

IEC 60092-351

3. Screen
- drain wire of tinned copper 1,0mm2 (in all sizes)
- aluminium polyester tape,
IEC 60092-350
coverage 100%
4. Sheath
- polyolefine plastic, SHF1
IEC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships,
especially when lightweight cables are needed.
Main characteristics
Rated voltage

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

17
Part number
Normal
G-type

27107
27111
27115
27119
27141
27123
27145
27149
27127
27131
27135
27156
27137

27109
27113
27117
27121
27143
27125
27147
27151
27129
27133
27139
27158
27153

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
32x1,5
37x1,5
2x2,5
3x2,5
4x2,5
5x2,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
32x2,5
37x2,5

9,0
9,5
10,0
11,0
12,0
15,5
16,0
16,5
17,5
18,5
22,0
22,5
23,5
25,0
9,5
10,5
11,0
12,5
13,5
17,5
18,0
18,5
19,5
21,0
25,0
25,5
26,5
28,5

100
125
150
175
220
310
350
395
450
510
650
710
825
935
130
160
195
240
300
430
495
565
635
740
930
1025
1195
1355

20
16
16
13
12
11
10
10
9
9
8
8
7
7
26
21
21
17
16
14
13
13
12
11
10
10
9
9

55
55
60
65
70
90
95
100
105
110
130
135
140
150
60
60
65
75
80
105
105
110
120
125
150
150
160
170

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

27102
27106
27110
27114
27118
27140
27122
27144
27148
27126
27130
27134
27155
27136
27104
27108
27112
27116
27120
27142
27124
27146
27150
27128
27132
27138
27157
27152

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKAM-HF 0,6/1kV

0,6/1kV CABLES

18

LKEM-HF

DESIGN:

5/2014

1. Conductor
- stranded flexible
copper conductor

Switchboard wire
0,6/1kV

STANDARDS:
IEC 60092-353, design
IEC 60228,
class 5

2. Insulation
- HF90 plastic
IEC 60092-351
- standard colour black, other colours on request
- on request, oil resistant thermosetting polyolefine, SHF2

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed wiring in switchboards, control panels and other enclosures.
Main characteristics
Rated voltage

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

-test for single insulated wire and cable

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Identification: Cable type, cable size, voltage and manufacturer's name

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

19

Part number

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

1x0,5
1x0,75
1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300

2,3
2,7
2,8
3,1
3,6
4,1
4,7
5,7
6,7
8,6
9,7
11,9
13,7
16,2
18,2
20,8
23,3
26,8
28,9

10
14
17
21
32
45
63
103
154
244
334
476
671
887
1125
1424
1753
2357
2900

11
14
17
22
30
39
50
71
94
123
153
196
240
284
331
381
429
507
582

10
15
15
15
15
20
20
25
30
35
40
50
55
65
75
85
95
110
120

* Rated voltage 300/500V


Available in colours:
blue, dark blue, black, brown, red, yellow, green, yellow/green, grey, orange, violet and white
Other colours on request

Delivery lengths:
0,5 mm2, 0,75 mm2, 1 mm2, 1,5 mm2 and 2,5 mm2 available in 200 m boxes or 500 m drums
4 mm2 available in 100 m boxes or 500 m drums
6 mm2 and 10 mm2 available in 100 m coils or 500 m drums
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

25117*
25120
25121
25122
25124
25125
25126
25128
25130
25132
25134
25136
25138
25165
25166
25279
25281
25283
25285

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKEM-HF 0,6/1kV

EMC CABLES

20

LKSM-EMC

Armoured power and control cable


with improved EMC screening 0,6/1kV

5/2014

DESIGN:

STANDARDS:
IEC 60092-353, design

1. Conductor
2
-stranded copper conductor 1,0-10mm 2 IEC 60228, class 2
-stranded copper conductor 16-300mm IEC 60228, class 5
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Bedding
- filler tape
4. Screen
- copper tape, coverage 100%
5. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1
IEC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
Design to meet requirements for improved EMC screening properties.
Main characteristics
Rated voltage

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Transfer impedance

IEC 61196-1

(typical value 26dB over 1m/m


at 100MHz [20m/m])

For details see general information section


Minimum recommended installation temperature -15 C
Lowest operation temperature -40 C
Core identification:

See technical information section.

Identification: Lot number, cable type, cable size, voltage, temperature,


standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

21

Part number
Normal
G-type

Diameter
of screen
mm

1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
2x70
2x95

4,0
4,0
4,5
5,0
6,0
7,0
8,5
10,5
11,5
14,0
16,0
18,5
20,0
23,0
25,5
29,0
31,0
6,5
7,0
8,0
9,0
10,5
12,5
15,5
19,5
21,5
26,0
29,5
34,5

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

Crosssection of
armour
mm2
3,0
3,0
3,0
3,1
3,1
3,3
4,2
4,9
5,6
8,8
10,0
11,5
12,4
14,7
15,3
17,1
18,8
3,3
3,6
4,1
4,6
5,1
8,5
11,4
12,4
14,7
16,4
18,8
21,3

Nominal
outer
diameter
mm

Approximate
weight
kg/km

Current
Rating A
at +45C

6,0
6,5
7,0
7,5
8,0
9,5
11,0
13,5
14,5
17,0
19,0
21,5
24,0
26,5
29,5
33,0
35,5
9,5
10,0
11,0
12,0
13,0
16,0
18,5
23,0
25,5
30,0
34,0
39,0

90
100
110
130
155
230
280
405
515
705
940
1185
1465
1815
2165
2795
3425
130
145
180
250
340
535
725
1045
1325
1785
2385
3100

18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
15
20
26
34
44
61
80
105
130
167
204
241

Min. bending
radius fixed
installation
mm
37
39
41
45
48
57
66
80
86
102
114
129
143
160
176
197
213
56
59
65
72
79
95
112
138
153
179
204
235

Table continues on next page

5/2014

26904
27513
27514
27515
27516
27517
27518
27519
27520
27521
27522
27523
27524
27525
27526
27527
27528
26905
27480
27481
27482
27483
27484
27485
27486
27487
27529
27530
27531

Number of
conductors &
cross-section
n x mm2

EMC CABLES

LKSM-EMC 0,6/1kV

EMC CABLES

22

LKSM-EMC 0,6/1kV

5/2014

Part number
Normal
G-type
26906
26861
26863
26865
26867
26869
26872
26874
26876
26878
26880
26882
26884
26886
26907
26942
26944
26946
26948
26950
26952
26954
26956
26958
26960
26962
26964
26966
26908
27488
27489
27490
27491
27492
27493
27494

26988
26862
26864
26866
26868
26870
26851
26852
26853
26854
26855
26856
26857
26858
26989
26943
26945
26947
26949
26951
26953
26955
26957
26959
26961
26963
26965
26967
26990
27838
27839
27940
27941
27942
27943
27944

Number of
conductors &
cross-section
n x mm2

Diameter
of screen
mm

3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16
5x25

7,0
7,5
8,5
10,0
11,0
13,5
16,5
21,0
23,0
27,5
32,0
37,0
41,5
47,5
8,0
8,5
9,5
11,0
12,5
15,0
18,0
23,0
25,5
31,0
35,5
42,0
46,5
52,5
8,5
9,5
10,5
12,5
14,0
16,5
20,0
25,5

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

Crosssection of
armour
mm2
3,6
3,9
4,3
5,0
5,6
8,9
10,9
14,6
15,2
18,3
22,0
22,9
37,9
39,4
3,9
4,3
4,9
5,5
8,5
9,9
12,0
14,8
18,2
19,6
22,6
37,9
39,4
43,7
4,2
4,7
5,3
11,3
11,4
11,0
13,3
16,4

Nominal
outer
diameter
mm

Approximate
weight
kg/km

Current
Rating A
at +45C

10,0
10,5
11,5
12,5
14,0
16,5
19,5
24,5
27,0
32,0
36,5
42,0
47,0
53,0
10,5
11,0
12,5
13,5
15,5
18,5
22,0
27,0
30,0
35,5
40,0
47,5
52,5
59,0
11,0
12,0
13,5
15,5
17,0
20,0
23,5
29,5

155
175
215
285
395
630
835
1245
1590
2205
2970
3825
4895
6060
175
200
260
340
505
750
1020
1510
1970
2715
3675
4935
6095
7610
200
240
305
460
615
875
1220
1775

13
16
21
28
36
50
66
86
107
137
168
199
232
267
13
16
21
28
36
50
66
86
107
137
168
199
232
267
10
13
17
23
30
42
55
71

Min. bending
radius fixed
installation
mm
59
62
68
76
84
100
118
147
162
193
219
252
283
319
63
67
74
82
94
110
131
161
179
213
241
284
314
355
67
73
80
92
102
120
142
177

Table continues on next page

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

23

Part number
Normal
G-type
26991
26992
26993
26994
26995
26996
26997
26998
26999
27840
27842
27844
27846
27848
27850
27852
27854
27856
27841
27843
27845
27847
27849
27851
27853
27855

Diameter
of screen
mm

7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
37x1,0
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5

9,5
12,5
13,0
13,5
14,5
15,0
18,0
18,5
20,5
10,0
13,5
14,0
15,0
15,5
16,5
19,5
20,0
22,5
11,5
15,5
16,0
17,0
18,0
19,0
22,5
23,0

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

Crosssection of
armour
mm2
4,7
9,9
9,9
9,9
10,0
10,2
12,2
12,5
14,1
5,2
9,2
10,0
10,2
10,8
11,4
13,6
13,9
15,7
5,8
11,4
11,5
11,5
12,2
12,9
15,3
15,8

Nominal
outer
diameter
mm

Approximate
weight
kg/km

12,5
15,5
16,0
16,5
17,5
18,5
21,5
22,0
24,5
13,0
16,5
17,0
18,0
19,0
20,0
23,0
24,0
26,5
14,5
18,5
19,0
20,0
21,5
22,5
26,0
27,0

240
365
395
430
465
550
695
750
935
285
420
465
520
570
675
855
930
1175
365
555
620
690
775
910
1145
1250

Current
Rating A
at +45C
9
8
8
7
7
7
6
6
5
23
20
16
16
13
23
20
16
23
30
26
21
21
17
30
26
21

Min. bending
radius fixed
installation
mm
74
93
96
100
105
111
130
132
147
78
99
102
108
113
119
139
143
160
87
111
115
120
128
135
157
161

5/2014

26909
26910
26911
26912
26913
26914
26915
26916
26917
27495
27497
27499
27501
27503
27505
27507
27509
27511
27496
27498
27500
27502
27504
27506
27508
27510

Number of
conductors &
cross-section
n x mm2

EMC CABLES

LKSM-EMC 0,6/1kV

EMC CABLES

24

LKSM-EMC-FRHF

5/2014

DESIGN:

Fire-resistant armoured power


and control cable with improved
EMC screening 0,6/1kV

STANDARDS:
IEC 60092-353, design

1. Conductor
2
-stranded copper conductor 1,0-10mm 2 IEC 60228, class 2
Flame-stranded copper conductor 16-300mm IEC 60228, class 5
retardant
- tinned stranded copper conductor on request
Fire2. Insulation
resistant
- Mica tape
Halogen- XLPE plastic
IEC 60092-351
free
3. Bedding
Low smoke
- filler tape
emission
4. Screen
Oil resistant
- copper tape, coverage 100%
(only SHF2)
5. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in all areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or cable with
black outer shetah is recommended. Design to meet requirements for improved
EMC screening properties.
Main characteristics
Rated voltage

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Fire -resistant

IEC 60331-1 and IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Transfer impedance

IEC 61196-1

(typical value 26dB over 1m/m


at 100MHz [20m/m])

For details see general information section


Minimum recommended installation temperature -15 C
Lowest operation temperature -40 C
Core identification:

See technical information section.

Identification: Lot number, cable type, cable size, voltage, temperature,


standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

25

27872
27873
27874
27875
27876
27877
27878
27879
27880
27881

2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16
2x25
2x35
2x50
2x70
2x95

3,3
4,1
4,6
5,1
5,6
9,0
11,4
12,7
14,8
16,7
19,1
21,5

9,5
10,5
11,5
13,0
14,0
16,5
19,0
23,5
26,0
30,0
34,5
40,0

135
165
190
270
390
570
745
1075
1355
1830
2435
3170

15
20
26
34
44
61
80
105
130
167
204
241

55
65
70
80
85
100
115
140
155
180
205
240

27882
27883
27884
27885
27886
27887
27888
27889
27890
27891
27892
27893
27894

3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150

3,6
4,4
4,9
5,5
11,3
9,7
11,6
14,7
15,9
18,5
22,2
43,2
38,3
40,2

10,0
11,5
12,5
13,5
15,5
17,5
20,5
25,5
28,0
33,0
37,5
44,0
48,0
54,5

155
210
260
325
505
665
900
1335
1695
2285
3060
4160
5010
6210

13
16
21
28
36
50
66
86
107
137
168
199
232
267

60
70
75
80
90
105
125
155
170
200
225
265
290
325

27897
27898
27899
27900
27905
27906
27907
27908
27909
27910
27912
27913

4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16
4x25
4x35
4x50
4x70
4x95
4x120
4x150

3,9
4,9
5,5
11,3
9,3
10,8
12,9
15,6
18,3
20,4
23,4
38,3
40,4
45,0

10,5
12,5
13,5
15,5
16,5
19,5
23,0
28,0
31,0
36,5
41,5
48,5
53,5
60,5

190
250
305
445
570
805
1105
1620
2105
2840
3830
5060
6260
7790

13
16
21
28
36
50
66
86
107
137
168
199
232
267

65
75
80
90
100
115
140
170
185
220
250
290
320
365

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

Nominal
outer
diameter
mm

Approximate
weight
kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

6,0
7,0
7,5
8,0
8,5
10,0
11,0
13,0
14,5
17,0
19,0
21,5
23,5
26,5
29,0
32,5
35,5

105
115
125
145
170
230
285
410
515
705
945
1195
1475
1820
2175
2800
3430

18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582

35
40
45
45
50
60
65
80
85
100
115
130
140
160
175
195
210

Table continues on next page

5/2014

1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300

Part number

Number of
conductors &
cross-section
n x mm2

EMC CABLES

Crosssection of
armour
mm2
3,0
3,0
3,1
3,1
3,1
3,5
4,1
4,9
5,5
8,7
9,9
11,5
12,3
14,7
15,2
17,0
18,7

LKSM-EMC-FRHF
0,6/1kV

EMC CABLES

26

27914
27915
27916
27917
27918
27919
27920

5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16
5x25

Crosssection of
armour
mm2
4,3
5,4
11,3
11,4
11,4
11,9
14,1
17,3

7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
30x1,0
37x1,0

5,2
8,5
9,9
9,9
10,0
11,4
12,4
12,7
13,2
14,4

12,5
15,5
16,0
17,0
17,5
18,5
21,5
22,0
23,0
24,5

250
360
405
440
480
550
690
735
795
930

9
8
8
7
7
7
6
6
6
5

75
95
95
100
105
110
130
135
135
150

27921
27923
27925
27927
27929
27931
27933
27935

27937

7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
30x1,5
37x1,5

14,1
10,6
11,0
11,7
12,4
13,1
15,6
15,9
16,5
18,0

15,0
18,5
19,0
20,0
21,5
22,5
26,0
27,0
27,5
30,0

400
485
535
590
675
750
945
1030
1110
1315

12
11
10
10
9
9
8
8
7
7

90
110
115
120
130
135
155
160
165
180

27922
27924
27926
27928
27930
27932
27934
27936

27938

7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
30x2,5
37x2,5

11,3
11,8
12,3
13,0
13,8
14,6
17,5
17,9
18,6
20,2

16,0
21,0
21,5
22,5
23,5
25,0
29,0
30,0
31,0
33,5

460
630
705
785
875
985
1245
1375
1490
1770

16
14
13
12
12
11
10
10
10
9

95
125
130
135
140
150
175
180
185
200

LKSM-EMC-FRHF
0,6/1kV

5/2014

Part number

Number of
conductors &
cross-section
n x mm2

Nominal
outer
diameter
mm

Approximate
weight
kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

11,5
13,5
15,0
16,5
18,5
21,5
25,0
30,5

220
290
415
525
685
975
1320
1880

10
13
17
23
30
42
55
71

70
80
90
100
110
130
150
185

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

27
EMC CABLES
5/2014

EMC CABLES

28

RFE-EMC

Armoured instrumentation and


communication cable with improved
EMC screening 250V

5/2014

DESIGN:

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Bedding
- filler tape
5. Screen
- drain wire copper (in all sizes)
- copper tape 100%
6. Armour
- copper wire braid, coverage >94%
EC 60092-350
- tinned copper wire braid on request
7. Sheath
- polyolefine plastic, SHF1
EC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Design to meet requirements for improved EMC screening properties.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant

150/250V (300V)

Halogen-free
Smoke emission

+ 90 C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series

Transfer impedance

IEC 61196-1

Electrical data:
Loop resistance of pair, max. / +20C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20C

(typical value 26dB over 1m/m


at 100MHz [20m/m])
0,5mm2 0,75mm2
80
52
55
50
0,6
0,6
1500
1500

1,5mm2
24,4
60
0,7
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: See technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

29

Part number

1x2x0,5
1x3x0,5
2x2x0,5 Quad
2x2x0,5
3x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
27x2x0,5
30x2x0,5
32x2x0,5
37x2x0,5
1x2x0,75
1x3x0,75
2x2x0,75 Quad
2x2x0,75
3x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
27x2x0,75
30x2x0,75
32x2x0,75
37x2x0,75
1x2x1,5
1x3x1,5
2x2x1,5 Quad
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

Nominal
outer
diameter
mm

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

7,0
7,0
7,5
9,5
10,0
11,0
13,0
13,5
15,5
16,0
17,5
18,0
19,5
21,5
22,5
23,5
24,5
26,0
8,0
8,0
9,0
11,0
11,5
13,0
15,5
16,5
18,5
19,0
20,5
22,0
23,5
26,0
27,0
28,5
29,5
31,0
10,0
10,5
11,5
14,5
15,0
17,0
20,5
22,0
24,5
26,0
27,5
29,5
31,5
35,5
37,0
39,0
40,0
43,5

95
105
115
150
165
185
270
290
365
395
445
480
540
655
710
775
810
900
110
130
150
175
200
255
365
400
475
520
600
655
755
900
980
1060
1140
1270
165
210
220
285
335
425
605
690
820
935
1045
1175
1335
1650
1810
1985
2090
2490

40
45
45
60
60
65
75
80
95
95
105
110
115
130
135
140
145
155
45
50
55
65
70
75
95
100
110
115
125
130
140
155
165
170
175
185
60
65
70
85
90
100
120
130
150
155
165
175
190
210
220
235
240
260

5/2014

21968
21969
21970
21971
21972
21973
21974
21975
21976
21977
21978
21979
21980
21981
21982
21983
21984
21985
21987
21988
21989
21990
21991
21992
21993
21994
21995
21996
21997
21998
21999
22000
22001
22002
22003
22004
22375
22376
22377
22378
22379
22380
22381
22382
22383
22384
22385
22386
22387
22388
22389
22390
22391
22392

Number of
conductors &
cross-section
n x mm2

EMC CABLES

RFE-EMC 250V

EMC CABLES

30

RFE-EMC(i)

Armoured and pair screened


instrumentation and communication cable
with improved EMC screening 250V

5/2014

DESIGN:

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Twisted pair & pair screen
- two insulated cores twisted together to form a pair
- plastic coated aluminium tape and a tinned copper drain wire
4. Bedding
- filler tape
5. Screen
- drain wire copper (in all sizes)
- copper tape 100%
6. Armour
- copper wire braid, coverage >94%
IEC 60092-350
- tinned copper wire braid on request
7. Sheath
- polyolefine plastic, SHF1
EC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Design to meet requirements for improved EMC screening properties.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant

150/250V (300V)

Halogen-free
Smoke emission

+ 90 C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series

Transfer impedance

IEC 61196-1

Electrical data:
Loop resistance of pair, max. / +20C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20C

(typical value 26dB over 1m/m


at 100MHz [20m/m])

0,5mm2 0,75mm2
80
52
55
70
0,6
0,6
1500
1500

1,5mm2
24,4
90
0,7
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: See technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

31

Part number

Number of
conductors &
cross-section
n x mm2

Nominal
outer
diameter
mm

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

1x2x0,5
1x3x0,5
1x4x0,5
2x2x0,5
3x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
27x2x0,5
30x2x0,5
32x2x0,5
37x2x0,5

7,0
7,0
7,5
10,0
10,0
11,0
13,0
14,0
16,0
16,5
17,5
18,5
20,0
22,0
23,0
24,0
25,0
26,5

90
100
120
150
175
205
300
360
430
490
540
590
690
835
910
990
1050
1180

40
45
45
60
60
65
80
85
95
100
105
110
120
135
140
145
150
160

21911
21912
21913
21914
21915
21916
21917
21918
21919
21920
21921
21922
21923
21924
21925
21926
21927
21928

1x2x0,75
1x3x0,75
1x4x0,75
2x2x0,75
3x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
27x2x0,75
30x2x0,75
32x2x0,75
37x2x0,75

7,5
8,0
9,0
11,5
12,0
13,0
15,5
16,5
19,0
20,0
21,0
22,5
24,0
26,5
28,0
29,0
30,0
32,0

105
115
150
185
215
255
390
435
530
590
660
740
840
1040
1135
1230
1310
1465

45
50
55
70
70
75
95
100
115
120
125
135
145
160
165
175
180
190

21930
21931
21932
21933
21934
21935
21936
21937
21938
21939
21940
21941
21942
21943
21944
21945
21946
21947

1x2x1,5
1x3x1,5
1x4x1,5
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5
27x2x1,5
30x2x1,5
32x2x1,5
37x2x1,5

10,0
10,5
11,5
14,5
16,0
17,0
20,5
22,0
25,0
26,0
28,0
29,5
32,0
36,0
37,5
40,0
41,0
44,0

160
190
220
280
370
440
645
730
890
1005
1150
1275
1490
1835
2015
2235
2450
2780

60
65
70
85
95
105
125
135
150
155
170
180
195
215
225
240
245
265

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

5/2014

21949
21950
21951
21952
21953
21954
21955
21956
21957
21958
21959
21960
21961
21962
21963
21964
21965
21966

EMC CABLES

RFE-EMC(i) 250V

1,8/3kV CABLES

32

LKSM-VFD

Armoured power and control cable


with improved EMC screening 1,8/3kV

5/2014

DESIGN:

STANDARDS:
IEC 60092-353, design

1. Conductor
- stranded copper conductor
IEC 60228, class 5
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Bedding
- filler tape
4. Screen
- copper tape, coverage 100%
5. Armour
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1
IEC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour black, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
Design to meet requirements for Variable Frequency Drivers (VFD).
Suitable for voltage peaks up to 3kV.
Main characteristics
Rated voltage

1,8/3kV (3,6kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Transfer impedance

IEC 61196-1

(typical value 26dB over 1m/m


at 100MHz [20m/m])

For details see general information section


Minimum recommended installation temperature -15 C
Lowest operation temperature -40 C
Core identification:

See technical information section.


Cable with yellow/green protective earth (PE)
conductor on request

Identification: Lot number, cable type, cable size, voltage, temperature,


standards, production month, manufacturer's name and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

33

Part number

1x16
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x95+3x16
3x120+3x25
3x150+3x25

5,5
8,5
9,3
10,3
11,3
12,5
13,6
14,7
15,8
17,6
18,9
16,4
16,9
18,7
28,8
35,0
35,4
38,6
42,0
45,5
35,4
38,6
42,0

Nominal
outer
diameter
mm

Approximate
weight
kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

14,0
16,0
17,0
19,0
20,5
23,5
25,5
27,5
29,5
33,0
35,0
26,5
29,5
32,5
37,0
41,0
46,5
50,5
55,0
60,0
46,5
50,5
55,0

355
495
625
795
995
1280
1525
1830
2165
2800
3365
1165
1525
1910
2580
3395
4295
5200
6255
7475
4655
5755
6825

94
123
153
196
240
284
331
381
429
507
582
66
86
107
137
168
199
232
267
300
199
232
267

85
95
105
115
125
140
150
165
180
200
210
160
180
195
225
245
280
305
330
360
280
305
330

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx
NOTE!
1) = Protective earth (PE) rules are not fulfilled.
(PE rules, for cables over 16mm2 the PE-conductor have to be half of main conductor
and min. 16mm2. This according to IEC 60092-352, Electrical installations
in ships Choice and installation of electrical cables)
2 = Three additional protective earth (PE) conductors.
Protective earth (PE) rules are fulfilled.

Note

1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)

1)
1)
1)
1)
2)
2)
2)

5/2014

26920
26922
26924
26926
26928
26930
26932
26934
26936
26938
26940
26871
26873
26875
26877
26879
26881
26883
26885
26887
26893
26895
26897

Number of
Crossconductors & section of
cross-section armour
n x mm2
mm2

1,8/3kV CABLES

LKSM-VFD 1,8/3kV

0,6/1kV CABLES

34

LKM-FRHF
DESIGN:

Fire-resistant unarmoured power


and control cable 0,6/1kV

STANDARDS:
IEC 60092-353, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2 (class 5 on request)
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic

IEC 60092-351

5/2014

3. Bedding
- separator tape

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant

4. Sheath
(only SHF2)
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

35

Part number
Normal
G-type

28279
28163
28165
28167
28169
28171
29367
29369
29371
29373
29375
29377
29379

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
2x95 Flex
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex

5,5
5,5
6,0
6,5
7,5
8,5
9,5
12,0
13,0
15,0
17,5
20,0
22,0
25,0
27,5
31,0
33,5
8,5
9,0
10,5
11,5
13,0
15,0
17,5
21,5
24,0
28,5
32,5
38,0
9,0
9,5
11,0
12,5
14,0
16,0
18,5
23,0
26,0
30,5
35,0
41,0
45,5

40
45
60
80
100
150
200
310
405
560
775
1000
1255
1580
1920
2540
3105
75
90
125
165
260
385
530
805
1095
1525
2075
2775
95
115
160
220
330
485
675
1030
1400
1970
2720
3570
4500

18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
15
20
26
34
44
61
80
105
130
167
204
241
13
16
21
28
36
50
66
86
107
137
168
199
232

30
35
35
40
45
50
40
50
55
65
70
80
90
100
170
190
205
50
55
65
70
75
90
70
90
100
175
200
230
55
60
65
75
85
95
75
95
155
185
215
245
275

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Table continues on next page

5/2014

28275
28100
28102
28104
28106
28108
29326
29327
29328
29329
29330
29331
29332
29333
29334
29335
29336
28276
28132
28134
28136
28138
28140
29343
29344
29345
29346
29347
29348
28278
28162
28164
28166
28168
28170
29366
29368
29370
29372
29374
29376
29378

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKM-FRHF 0,6/1kV

5/2014

0,6/1kV CABLES

36

LKM-FRHF 0,6/1kV
Part number
Normal
G-type
28280
28182
28184
28186
28188
28190
29400
29402
29404
29406
29408
29410
28282
28212
28214
28501
28503
28505
29434
29436
29438
29440

28281
28183
28185
28187
28189
28191
29401
29403
29405
29407
29409
29411
28283
28213
28215
28502
28504
28506
29435
29437
29439
29441

Number of
conductors &
cross-section
n x mm2

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
5x35 Flex
5x50 Flex

9,5
11,0
12,0
13,5
15,0
18,0
20,5
26,0
28,5
34,5
39,0
46,0
11,0
12,0
13,0
15,0
16,5
19,5
22,5
28,5
31,5
38,0

115
150
200
280
405
610
865
1330
1790
2530
3475
4615
150
185
240
345
505
750
1050
1640
2215
3120

13
16
21
28
36
50
66
86
107
137
168
199
10
13
17
23
30
42
55
71
89
114

60
65
75
80
90
105
85
155
175
210
235
275
65
70
80
90
100
115
95
175
195
230

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Table continues on next page

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

37

Part number
Normal
G-type
28285
28287
28289
28291
28293
28295
28297
28299
28301
28217
28241
28221
28245
28249
28225
28229
28233
28235
28219
28243
28223
28247
28251
28227
28231
28237
28239

7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
37x1,0
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
37x2,5

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

12,0
15,0
15,5
16,5
17,5
18,5
21,5
22,0
25,0
13,0
16,5
17,5
18,5
19,5
20,5
24,5
25,0
28,0
14,5
18,5
19,5
20,5
21,5
23,0
27,5
28,0
31,5

180
260
295
330
380
435
550
600
805
230
330
380
430
485
565
725
795
1050
315
450
510
590
670
765
995
1095
1450

9
8
8
7
7
7
6
6
5
12
11
10
10
9
9
8
8
7
16
14
13
13
12
11
10
10
9

70
90
95
100
105
110
130
130
150
80
100
105
110
115
125
145
150
170
90
110
115
125
130
135
165
170
190

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

28284
28286
28288
28290
28292
28294
28296
28298
28300
28216
28240
28220
28244
28248
28224
28228
28232
28234
28218
28242
28222
28246
28250
28226
28230
28236
28238

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKM-FRHF 0,6/1kV

0,6/1kV CABLES

38

LKSM-FRHF
DESIGN:

Fire-resistant armoured power


and control cable 0,6/1kV

STANDARDS:
IEC 60092-353, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2 (class 5 on request)
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic

EC 60092-351

5/2014

3. Bedding
- separator tape
4. Armour
- copper wire braid, coverage > 90%
- tinned copper wire braid on request

IEC 60092-350

5. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

39

Part number
Normal
G-type

28544
28623
28625
28627
28629
28631
29083
29085
29087
29089
29091
29093
29095

Crosssection of
armour
mm2

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

1x1,0
1x1,5
1x2,5
1x4
1x6
1x10
1x16 Flex
1x25 Flex
1x35 Flex
1x50 Flex
1x70 Flex
1x95 Flex
1x120 Flex
1x150 Flex
1x185 Flex
1x240 Flex
1x300 Flex
2x1,0
2x1,5
2x2,5
2x4
2x6
2x10
2x16 Flex
2x25 Flex
2x35 Flex
2x50 Flex
2x70 Flex
2x95 Flex
3x1,0
3x1,5
3x2,5
3x4
3x6
3x10
3x16 Flex
3x25 Flex
3x35 Flex
3x50 Flex
3x70 Flex
3x95 Flex
3x120 Flex

3,0
3,0
3,1
3,1
3,1
3,5
4,1
5,2
5,5
8,7
11,4
11,5
12,3
14,7
15,2
18,2
18,7
3,5
3,8
4,3
4,9
5,4
8,7
10,0
14,5
14,7
18,1
18,7
22,2
4,1
4,1
4,6
5,2
5,8
9,3
10,7
14,6
15,0
17,5
22,0
22,8
37,8

6,5
7,0
7,0
8,0
8,5
10,0
11,0
13,5
14,5
17,5
19,5
22,0
24,0
27,0
29,5
33,0
36,0
10,0
10,5
11,5
13,0
14,0
16,5
19,0
24,0
26,0
30,5
35,0
40,0
10,5
11,0
12,0
13,5
15,0
17,5
20,0
25,5
28,0
33,0
37,5
43,0
48,0

75
80
95
115
140
195
255
380
475
665
905
1135
1410
1745
2090
2735
3325
120
140
170
225
340
505
665
1035
1300
1765
2345
3045
145
170
210
280
400
595
800
1225
1570
2170
2935
3775
4840

18
23
30
40
52
72
94
123
153
196
240
284
331
381
429
507
582
15
20
26
34
44
61
80
105
130
167
204
241
13
16
21
28
36
50
66
86
107
137
168
199
232

40
40
45
45
50
60
70
85
90
105
120
135
150
165
180
200
215
60
65
70
75
85
100
115
145
160
185
210
245
60
65
75
80
90
105
125
155
170
200
225
260
290

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Table continues on next page

5/2014

28541
28568
28570
28572
28574
28576
29060
29061
29062
29063
29064
29065
29066
29067
29068
29069
29070
28542
28602
28604
28606
28608
28610
29071
29072
29073
29074
29075
29076
28543
28622
28624
28626
28628
28630
29082
29084
29086
29088
29090
29092
29094

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKSM-FRHF 0,6/1kV

5/2014

0,6/1kV CABLES

40

LKSM-FRHF 0,6/1kV
Part number
Normal
G-type
28545
28642
28644
28646
28648
28650
29104
29106
29108
29110
29112
29114
28547
28662
28664
28705
28707
28709
29126
29128
29130
29132
28549
28551
28553
28555
28557
28559
28561
28563
28565
28666
28723
28670
28727
28731
28674
28678
28682
28684
28668
28725
28672
28729
28733
28676
28680
28686
28688

28546
28643
28645
28647
28649
28651
29105
29107
29109
29111
29113
29115
28548
28663
28665
28706
28708
28710
29127
29129
29131
29133
28550
28552
28554
28556
28558
28560
28562
28564
28566
28667
28724
28671
28728
28732
28675
28679
28683
28685
28669
28726
28673
28730
28734
28677
28681
28687
28689

Number of
conductors &
cross-section
n x mm2
4x1,0
4x1,5
4x2,5
4x4
4x6
4x10
4x16 Flex
4x25 Flex
4x35 Flex
4x50 Flex
4x70 Flex
4x95 Flex
5x1,0
5x1,5
5x2,5
5x4
5x6
5x10
5x16 Flex
5x25 Flex
5x35 Flex
5x50 Flex
7x1,0
10x1,0
12x1,0
14x1,0
16x1,0
19x1,0
24x1,0
27x1,0
37x1,0
7x1,5
10x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
37x1,5
7x2,5
10x2,5
12x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5
37x2,5

Crosssection of
armour
mm2

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

4,1
4,5
5,0
5,7
8,8
10,3
11,9
14,8
18,1
19,5
22,6
35,0
4,5
5,0
5,6
8,6
9,7
11,5
13,2
18,1
18,6
22,4
4,9
8,7
9,0
11,4
11,4
11,4
12,5
12,8
14,4
5,4
9,6
9,9
11,4
11,5
11,7
13,9
14,1
16,0
8,5
11,5
11,5
11,8
12,5
13,2
15,7
16,1
18,1

11,0
12,0
13,5
14,5
16,5
19,5
22,5
28,0
30,5
36,5
41,0
48,5
12,0
13,5
14,5
16,5
18,0
21,0
24,5
30,5
34,0
40,0
13,0
16,5
17,0
18,0
19,0
20,0
23,5
24,0
26,5
14,5
18,0
19,0
20,0
21,0
22,0
26,0
26,5
29,5
16,0
20,0
21,0
22,5
23,5
24,5
29,0
29,5
33,0

170
200
255
335
505
725
1010
1515
1980
2730
3695
4935
195
245
305
440
600
870
1135
1735
2390
3330
240
355
395
455
505
555
695
750
960
295
430
490
555
610
680
875
945
1220
405
570
635
730
815
920
1165
1265
1660

13
16
21
28
36
50
66
86
107
137
168
199
10
13
17
23
30
42
55
71
89
114
9
8
8
7
7
7
6
6
5
12
11
10
10
9
9
8
8
7
16
14
13
13
12
11
10
10
9

65
70
80
90
100
115
135
170
185
220
250
290
70
80
85
100
110
125
150
185
205
245
80
100
100
105
115
120
140
145
160
85
110
115
120
125
130
155
160
180
95
120
125
135
140
145
175
175
200

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

41
0,6/1kV CABLES
5/2014

0,6/1kV CABLES

42

LKAM-FRHF
DESIGN:

Fire-resistant screened power


and control cable 0,6/1kV

STANDARDS:
IEC 60092-353, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic

IEC 60092-351

5/2014

3. Screen
- drain wire of tinned copper 1,0mm2 (in all sizes)
- aluminium polyester tape,
IEC 60092-350
coverage 100%

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

4. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request

Application: For fixed installation in most areas and on open deck in ships,
especially when lightweight cables are needed.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage

AC 0,6/1kV (1,2kV)
DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: see technical information section
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

43

Part number
Normal
G-type

28744
28748
28752

28746
28750
28754

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

2x1,5
3x1,5
4x1,5
5x1,5
7x1,5
12x1,5
14x1,5
16x1,5
19x1,5
24x1,5
27x1,5
2x2,5
3x2,5
4x2,5
5x2,5
14x2,5
16x2,5
19x2,5
24x2,5
27x2,5

9,5
10,5
11,0
12,0
13,5
17,5
18,5
19,5
20,5
24,5
25,0
10,5
11,5
12,5
13,5
20,5
22,0
23,5
27,5
28,0

115
140
165
200
250
400
450
515
580
740
810
140
175
215
270
625
700
820
1035
1140

20
16
16
13
12
10
10
9
9
8
8
26
21
21
17
13
12
11
10
10

60
60
65
75
80
105
110
120
125
145
150
65
70
75
80
125
130
140
165
170

G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

28741
28743
28747
28751
28755
28763
28767
28771
28775
28779
28783
28742
28745
28749
28753
28769
28773
28777
28781
28785

Number of
conductors &
cross-section
n x mm2

0,6/1kV CABLES

LKAM-FRHF 0,6/1kV

250V CABLES

44

LKM-HF

Unarmoured control and


instrumentation cable
250V

DESIGN:

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic

IEC 60092-351

5/2014

3. Bedding
- separator tape
4. Sheath
- polyolefine plastic, SHF1
EC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended..
Main characteristics
Rated voltage

150/250V (300V)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

45

Part number

Nominal
outer
diameter
mm

2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
14x0,5
16x0,5
19x0,5
20x0,5
24x0,5
27x0,5
32x0,5
37x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75

6,0
6,5
7,0
7,5
8,0
10,5
10,5
11,0
12,0
12,5
13,5
14,5
15,0
15,5
16,5
6,5
7,0
7,5
8,0
8,5
11,0
11,5
12,0
13,0
13,5
14,5
16,0
16,5
17,0
18,0

Other sizes on request.


Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Approximate
weight kg/km
40
50
60
70
85
125
140
160
175
200
220
250
275
310
350
50
60
75
85
110
160
180
200
235
265
285
335
365
415
470

Current
Rating A
at +45C
8,7
7,6
6,9
6,4
5,8
5,1
4,8
4,6
4,4
4,1
4,1
3,8
3,7
3,5
3,3
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3

Min. bending
radius fixed
installation
mm
25
25
30
30
30
40
45
45
45
50
55
60
60
60
65
25
30
30
30
35
45
45
50
50
55
60
65
65
65
70

5/2014

27821
27822
27823
27824
27825
27826
27827
27828
27829
27830
27831
27832
27833
27834
27835
26365
26366
26367
26368
26369
26370
26371
26372
26373
26374
26375
26376
26377
26378
26379

Number of
conductors &
cross-section
n x mm2

250V CABLES

LKM-HF 250V

250V CABLES

46

LKSM-HF

Armoured control and


instrumentation cable
250V

5/2014

DESIGN:

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Bedding
- separator tape
4. Armour
- drain wire copper (in all sizes)
- copper wire braid, coverage > 90%
IEC 60092-350
- tinned copper wire braid on request
5. Sheath
- polyolefine plastic, SHF1
EC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage

150/250V (300V)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

47

Part number

2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
14x0,5
16x0,5
19x0,5
20x0,5
24x0,5
27x0,5
32x0,5
37x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75

Other sizes on request.


Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Crosssection of
armour
mm2
3,1
3,1
3,1
3,2
3,5
4,6
4,8
5,1
5,5
5,8
6,1
6,8
6,9
9,9
10,9
3,6
3,6
3,6
4,1
4,1
5,1
5,3
5,6
6,1
6,3
11,0
11,7
11,7
11,8
11,9

Nominal
outer
diameter
mm
7,0
7,5
8,0
8,5
9,0
11,5
11,5
12,0
12,5
13,5
14,0
15,5
15,5
16,5
18,0
7,5
7,5
8,5
9,5
10,0
12,5
12,5
13,0
14,0
14,5
18,0
17,0
17,5
18,0
19,5

Approximate
weight kg/km
80
85
95
110
125
180
195
215
235
265
285
325
345
420
470
90
100
115
140
165
220
245
270
300
330
455
450
485
545
605

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

8,7
7,6
6,9
6,4
5,8
5,1
4,8
4,6
4,4
4,1
4,1
3,8
3,7
3,5
3,3
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3

40
45
45
50
55
70
70
70
75
80
85
90
95
100
105
45
45
50
55
60
75
75
80
85
85
110
100
105
110
115

5/2014

27779
27780
27781
27782
27783
27784
27785
27786
27787
27788
27789
27790
27791
27792
27793
26402
26403
26404
26405
26407
26410
26412
26414
26416
26419
26420
26424
26427
26432
26437

Number of
conductors &
cross-section
n x mm2

250V CABLES

LKSM-HF 250V

250V CABLES

48

LKAM-HF

Screened control and


instrumentation cable
250V

DESIGN:

STANDARDS:
IEC 60092-376, design

5/2014

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic

IEC 60092-351

3. Screen
- drain wire of tinned copper
- aluminium polyester tape,
coverage 100%

IEC 60092-350

4. Sheath
- polyolefine plastic, SHF1
EC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships,
especially when lightweight cables are needed.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage

150/250V (300V)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

49

Part number

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

2x0,5
3x0,5
4x0,5
5x0,5
7x0,5
10x0,5
12x0,5
14x0,5
16x0,5
19x0,5
20x0,5
24x0,5
27x0,5
32x0,5
37x0,5
2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75

6,0
6,5
7,0
7,5
8,0
10,5
11,0
11,5
12,0
12,5
13,5
14,5
15,0
15,5
16,5
6,5
7,0
7,5
8,0
9,0
11,5
12,0
12,5
13,0
13,5
17,0
16,0
16,5
17,0
18,5

45
55
65
75
90
130
145
165
180
205
225
260
280
325
365
55
65
80
95
120
165
190
215
240
270
345
340
370
430
485

8,7
7,6
6,9
6,4
5,8
5,1
4,8
4,6
4,4
4,1
4,1
3,8
3,7
3,5
3,3
11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3

25
25
30
30
30
40
45
45
45
50
55
60
60
60
65
25
30
30
30
35
45
45
50
50
55
70
65
65
70
75

Other sizes on request.


Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

26440
26441
26442
26443
26444
26445
26446
26447
26448
26449
26450
26451
26452
26453
26454
26382
26383
26384
26385
26386
26387
26388
26389
26390
26391
26392
26393
26394
26395
26396

Number of
conductors &
cross-section
n x mm2

250V CABLES

LKAM-HF 250V

250V CABLES

50

RFE-HF

Armoured instrumentation
and communication cable
250V

5/2014

DESIGN:

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Bedding
- filler tape
5. Armour
- drain wire copper (in all sizes)
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1
EC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant

150/250V (300V)

Halogen-free
Smoke emission

+ 90 C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Electrical data:
Loop resistance of pair, max. / +20C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20C

0,5mm2 0,75mm2
80
52
55
50
0,6
0,6
1500
1500

1,5mm2
24,4
60
0,7
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

51

Part number

Nominal
outer
diameter
mm

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

7,0
8,0
10,5
11,5
14,0
14,5
17,0
17,5
18,5
19,5
21,0
23,5
28,0
7,5
9,0
11,0
12,5
15,5
16,0
18,5
19,0
20,5
21,5
23,5
26,0
29,5
9,5
11,0
14,0
17,0
20,0
21,5
24,5
25,5
27,0
31,0
35,0
39,5

85
105
130
175
245
270
355
390
440
485
545
670
930
95
125
155
215
330
375
440
490
565
620
715
860
1100
135
190
235
375
545
625
760
855
960
1230
1530
1950

45
50
60
70
85
85
100
105
110
120
125
140
170
45
55
65
75
90
95
110
115
125
130
140
155
175
60
65
85
100
120
130
145
155
165
185
210
235

1x2x0,5
2x2x0,5 Quad
2x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
37x2x0,5
1x2x0,75
2x2x0,75 Quad
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
1x2x1,5
2x2x1,5 Quad
2x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
19x2x1,5
24x2x1,5
32x2x1,5

Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
(Quad)cable is built up as a star quad
with the following identification
1 core
white
2 core
blue
3 core
white
4 core
blue

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

5/2014

20362
20364
20363
20366
20368
20369
20370
20371
20372
20373
20374
20376
20378
20382
20384
20383
20386
20388
20389
20390
20391
20392
20393
20394
20396
20398
20490
20491
20492
20493
20494
20495
20496
20497
20498
20499
20500
20501

Number of
conductors &
cross-section
n x mm2

250V CABLES

RFE-HF 250V

250V CABLES

52

RFE-HF (i)

5/2014

DESIGN:

Armoured and pair screened


instrumentation and communication
cable 250V

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Twisted pair & pair screen
- two insulated cores twisted together to form a pair
- plastic coated aluminium tape and a tinned copper drain wire
4. Bedding
- filler tape
5. Armour
- drain wire copper (in all sizes)
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1
EC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant

150/250V (300V)

Halogen-free
Smoke emission

+ 90 C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Electrical data:
Loop resistance of pair, max. / +20C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20C

0,5mm2 0,75mm2
80
52
55
70
0,6
0,6
1500
1500

1,5mm2
24,4
90
0,7
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

53

Part number

Nominal
outer
diameter
mm

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

1x2x0,5
1x3x0,5
1x4x0,5
2x2x0,5
3x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
27x2x0,5
30x2x0,5
32x2x0,5
37x2x0,5
1x2x0,75
1x4x0,75
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
1x2x1,5
1x4x1,5
2x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
19x2x1,5

7,5
7,5
8,0
10,5
11,0
12,0
14,0
15,5
17,5
18,0
19,0
20,0
22,0
24,0
25,5
26,5
27,5
29,0
7,5
9,0
11,5
13,0
15,5
16,5
19,0
20,0
21,0
24,0
27,0
10,0
11,0
14,5
17,0
20,0
22,0
25,0
26,0
28,0
32,0

90
105
120
155
185
215
320
385
470
530
590
655
770
935
1030
1120
1190
1340
95
140
170
240
375
420
520
585
650
835
1035
145
200
255
415
610
700
855
965
1105
1440

45
45
50
65
65
70
85
90
105
110
115
120
130
145
150
160
165
175
45
55
70
75
95
100
115
120
125
145
160
60
65
85
100
120
130
150
155
165
190

Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

22338
22340
22342
22344
22346
22348
22350
22352
22354
22356
22358
22360
22362
22364
22366
22368
22370
22372
22006
22008
22010
22012
22014
22016
22018
22020
22022
22024
22026
22050
22052
22054
22056
22058
22060
22062
22064
22066
22068

Number of
conductors &
cross-section
n x mm2

250V CABLES

RFE-HF(i) 250V

250V CABLES

54

RFA-HF

Screened instrumentation
and communication cable
250V

5/2014

DESIGN:

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Screen
- drain wire tinned copper
- aluminium polyester tape
IEC 60092-350
coverage 100%
5. Sheath
- polyolefine plastic, SHF1
EC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships, especially
when lightweight cables are needed. If the cable is exposed to direct
sun light protective covering or cable with black outer sheath is
recommended.
Main characteristics
Rated voltage

150/250V (300V)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Electrical data
Loop resistance of pair, max. / +20C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20C

0,5mm2 0,75mm2
80
52
55
50
0,6
0,6
1500
1500

1,5mm2
24,4
60
0,7
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

55

Part number

Nominal
outer
diameter
mm

1x2x0,5
2x2x0,5 Quad
2x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
32x2x0,5
37x2x0,5
1x2x0,75
2x2x0,75 Quad
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
1x2x1,5
1x3x1,5
2x2x1,5 Quad
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5

Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
(Quad)cable is built up as a star quad
with the following identification
1 core
white
2 core
blue
3 core
white
4 core
blue
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

6,0
7,0
9,0
10,5
12,5
13,5
15,5
16,0
17,5
18,0
20,0
22,0
25,5
27,0
6,5
7,5
10,0
11,5
14,0
15,0
17,0
18,0
19,0
20,5
22,0
24,5
8,5
9,0
10,0
13,0
14,0
15,5
18,5
20,0
23,0
24,0
26,0
27,5
30,0
33,5

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

45
65
75
120
175
200
245
280
315
350
410
515
665
745
55
80
100
150
225
260
320
365
415
480
555
680
85
125
140
165
210
260
410
465
590
675
780
875
1025
1285

35
40
55
65
75
80
95
95
105
110
120
135
150
160
40
45
60
70
85
90
100
105
115
125
130
145
50
55
60
80
85
90
110
120
140
145
155
165
180
200

5/2014

20910
20912
20914
20916
20918
20920
20922
20924
20926
20928
20930
20932
20934
20936
20970
20972
20974
20976
20978
20980
20982
20984
20986
20988
20990
20992
21356
21357
21358
21359
21360
21361
21362
21363
21364
21365
21366
21367
21368
21369

Number of
conductors &
cross-section
n x mm2

250V CABLES

RFA-HF 250V

250V CABLES

56

RFA-HF (i)

5/2014

DESIGN:

Collectively and pair screened


instrumentation and
communication cable 250V

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- XLPE plastic
IEC 60092-351
3. Twisted pair & pair screen
- two insulated cores twisted together to form a pair
- plastic coated aluminium tape and a tinned copper drain wire
4. Bedding
- separator tape
5. Collective screen
- drain wire tinned copper
IEC 60092-350
- aluminium polyester tape, coverage 100%
6. Sheath
- polyolefine plastic, SHF1
EC 60092-359
- on request, thermosetting polyolefine, SHF2
- standard colour grey, other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships, especially
when lightweight cables are needed. If the cable is exposed to direct
sun light protective covering or cable with black outer sheath is
recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant
Halogen-free
Smoke emission

150/250V (300V)
+ 90 C
IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series

Electrical data
Loop resistance of pair, max. / +20C
Pair capacitance, nom.
Loop inductance, nom.
Insulation resistance / +20C

0,5mm2 0,75mm2
80
52
55
70
0,6
0,6
1500
1500

1,5mm2
24,4
90
0,7
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

57

Part number

Nominal
outer
diameter
mm

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

2x2x0,5
4x2x0,5
7x2x0,5
8x2x0,5
10x2x0,5
12x2x0,5
14x2x0,5
16x2x0,5
19x2x0,5
24x2x0,5
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
1x2x1,5
1x3x1,5
2x2x1,5
3x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5
24x2x1,5

9,5
11,0
13,0
14,0
16,0
16,5
17,5
19,0
20,0
22,5
10,0
12,0
14,5
15,0
17,5
18,0
19,5
21,0
22,5
25,0
8,5
9,0
13,5
14,0
15,5
19,0
20,5
23,5
24,5
26,5
28,0
30,0
34,0

95
145
220
245
305
350
395
450
520
655
115
180
275
310
380
440
520
580
680
840
95
120
185
240
305
480
560
690
800
910
1035
1200
1520

55
65
80
85
95
100
105
115
120
135
60
70
85
90
105
110
120
125
135
150
50
55
80
85
95
115
125
140
150
160
170
180
205

Other sizes on request.

Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The pairs are covered by a numbered tape (1, 2, 3, 4, 5....)
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

20940
20942
20944
20946
20948
20950
20952
20954
20956
20958
21059
21061
21063
21065
21067
21069
21071
21073
21075
21077
21375
21376
21378
21379
21380
21381
21382
21383
21384
21385
21386
21387
21388

Number of
conductors &
cross-section
n x mm2

250V CABLES

RFA-HF(i) 250V

250V CABLES

58

LKM-FRHF
DESIGN:

Fire-resistant unarmoured
control and instrumentation
cable 250V

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic

IEC 60092-351

5/2014

3. Bedding
- separator tape

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

4. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage

150/250V (300V)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

59

Part number

Nominal
outer
diameter
mm

Approximate
weight kg/km

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75

8,5
9,0
10,0
11,0
11,5
15,0
15,5
16,5
17,5
18,0
19,0
21,5
22,0
23,0
25,0

65,0
80,0
110,0
130,0
160,0
225,0
255,0
295,0
330,0
375,0
410,0
475,0
520,0
615,0
695,0

11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3

35
35
40
45
45
60
60
65
70
75
75
85
85
90
100

Other size on request.


Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

22406
22407
22408
22409
22410
22411
22412
22413
22414
22415
22416
22417
22418
22419
22420

Number of
conductors &
cross-section
n x mm2

250V CABLES

LKM-FRHF 250V

250V CABLES

60

LKSM-FRHF
DESIGN:

Fire-resistant armoured
control and instrumentation
cable 250V

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic

EC 60092-351

5/2014

3. Bedding
- separator tape
4. Armour
- drain wire copper (in all sizes)
- copper wire braid, coverage > 90%
- tinned copper wire braid on request

IEC 60092-350

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

5. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage

150/250V (300V)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

61

Part number

2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75

Other size on request.


Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Crosssection of
armour
mm2
3,6
3,9
4,4
4,9
5,4
7,1
7,3
7,8
11,3
11,9
12,9
14,3
14,6
15,3
16,7

Nominal
outer
diameter
mm
9,0
9,5
11,0
11,5
12,5
16,0
16,0
17,0
18,5
19,5
20,5
22,5
23,0
23,5
26,0

Approximate
weight kg/km
105
125
160
185
220
300
330
370
445
495
545
615
665
740
860

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3

55
60
65
70
75
95
95
100
110
115
125
135
140
140
155

5/2014

22436
22437
22438
22439
22440
22441
22442
22443
22444
22445
22446
22447
22448
22449
22450

Number of
conductors &
cross-section
n x mm2

250V CABLES

LKSM-FRHF 250V

250V CABLES

62

LKAM-FRHF
DESIGN:

Fire-resistant screened control


and instrumentation cable
250V

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request

5/2014

2. Insulation
- Mica tape
- XLPE plastic

IEC 60092-351

3. Screen
- drain wire of tinned copper
- aluminium polyester tape,
coverage 100%

IEC 60092-350

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

4. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request

Application: For fixed installation in most areas and on open deck in ships,
especially when lightweight cables are needed.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage

150/250V (300V)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Fire-resistant

IEC 60331-1 or IEC 60331-2

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Core identification: black numbers on white base
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

63

Part number

2x0,75
3x0,75
4x0,75
5x0,75
7x0,75
10x0,75
12x0,75
14x0,75
16x0,75
19x0,75
20x0,75
24x0,75
27x0,75
32x0,75
37x0,75

Other size on request.


Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Nominal
outer
diameter
mm
8,5
9,0
10,0
11,0
11,5
15,0
15,5
16,5
17,5
18,0
19,5
21,5
22,0
23,0
25,0

Approximate
weight kg/km
70
85
115
135
165
230
260
300
340
380
415
480
525
620
700

Current
Rating A
at +45C

Min. bending
radius fixed
installation
mm

11,3
9,8
8,9
8,3
7,4
6,6
6,2
5,9
5,6
5,3
5,2
4,9
4,7
4,5
4,3

50
55
60
65
70
90
95
100
105
110
115
130
130
140
150

5/2014

22466
22467
22468
22469
22470
22471
22472
22473
22474
22475
22476
22477
22478
22479
22480

Number of
conductors &
cross-section
n x mm2

250V CABLES

LKAM-FRHF 250V

250V CABLES

64

RFE-FRHF

Fire-resistant armoured instrumentation


and communication cable
250V

5/2014

DESIGN:

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-351
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Bedding
- filler tape
5. Armour
- drain wire (in all sizes)
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage

150/250V (300V)

Maximum conductor
temperature

+ 90 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A

Fire-resistant
Halogen-free
Smoke emission

IEC 60331-1 or IEC 60331-2


IEC 60754 series
IEC 61034 series

Oil resistance (only SHF2)

IEC 60811-2-1 conditions according to 60092-359/SHF2

Electrical data
Loop resistance of pair, max. / +20C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20C

0,75mm2 1,5mm2
52
24,4
45
55
0,6
0,7
1500
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath
Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

65

Part number

Nominal
outer
diameter
mm

1x2x0,75
2x2x0,75 Quad
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
1x2x1,5
2x2x1,5 Quad
2x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5

9,5
11,0
14,0
16,5
20,0
21,0
24,5
25,5
27,0
31,0
34,5
39,4
10,5
12,0
16,0
18,5
22,5
24,0
27,5
29,0
30,5
33,0
35,2

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

115
170
210
330
470
515
640
710
810
1025
1260
1605
155
220
315
430
655
725
880
1010
1135
1290
1475

55
65
85
100
120
125
145
150
165
185
205
235
65
70
95
110
135
145
165
175
185
195
210

Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
(Quad)cable is built up as a star quad
with the following identification
1 core
white
2 core
blue
3 core
white
4 core
blue

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

5/2014

20520
20522
20524
20526
20528
20530
20532
20534
20536
20538
20540
20542
20575
20577
20579
20581
20583
20585
20587
20589
20591
20593
20595

Number of
conductors &
cross-section
n x mm2

250V CABLES

RFE-FRHF 250V

250V CABLES

66

RFE-FRHF (i)

5/2014

DESIGN:

Fire-resistant armoured and


pair screened instrumentation and
communication cable 250V

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
Flame- Mica tape
retardant
- XLPE plastic
IEC 60092-351
Fire3. Twisted pair & pair screen
resistant
- two insulated cores twisted together to form a pair
Halogen- plastic coated aluminium tape and a tinned copper drain wire
free
4. Bedding
Low smoke
- filler tape
emission
5. Armour
Oil resistant
- drain wire copper
(only SHF2)
- copper wire braid, coverage > 94%
IEC 60092-350
- tinned copper wire braid on request
6. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request
Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant

Fire-resistant
Halogen-free
Smoke emission

150/250V (300V)
+ 90 C
IEC 60332-1-2
IEC 60332-3-22

-test for single insulated wire and cable


-test for bunched wires and cables,
category A

IEC 60331-1 or IEC 60331-2


IEC 60754 series
IEC 61034 series

Electrical data
Loop resistance of pair, max. / +20C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20C

0,75mm2 1,5mm2
52
24,4
55
75
0,6
0,7
1500
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

67

Part number

Nominal
outer
diameter
mm

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

1x2x0,75
1X4X0,75
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
19x2x0,75
24x2x0,75
32x2x0,75
1x2x1,5
1X4X1,5
2x2x1,5
4x2x1,5
7x2x1,5
8x2x1,5
10x2x1,5
12x2x1,5
14x2x1,5
16x2x1,5
19x2x1,5

9,5
11,0
14,5
17,0
20,0
22,0
25,0
26,0
27,5
32,0
35,0
41,0
10,5
12,0
16,5
19,0
23,0
24,5
28,0
29,5
31,5
33,5
36,0

125
175
225
355
510
585
710
800
910
1175
1425
1945
165
225
320
475
720
805
985
1145
1290
1450
1665

55
65
85
100
120
130
150
155
165
190
210
245
65
75
100
115
135
145
165
175
190
200
215

Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)
Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

5/2014

20546
20548
20550
20552
20554
20556
20558
20560
20562
20564
20566
20568
20603
20604
20605
20607
20609
20611
20613
20615
20617
20619
20621

Number of
conductors &
cross-section
n x mm2

250V CABLES

RFE-FRHF(i) 250V

250V CABLES

68

RFA-FRHF

Fire-resistant screened
instrumentation and
communication cable 250V

5/2014

DESIGN:

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-351
3. Twisted pair
- two insulated cores twisted together to form a pair
See next page for Quad
4. Screen
- drain wire tinned copper
- aluminium polyester tape, coverage 100% IEC 60092-350
5. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant

150/250V (300V)
+ 90 C
IEC 60332-1-2
IEC 60332-3-22

-test for single insulated wire and cable


-test for bunched wires and cables,
category A

Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
For details see general information section
Electrical data
Loop resistance of pair, max. / +20C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20C

0,75mm2 1,5mm2
52
24,4
45
55
0,6
0,7
1500
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

69

Part number
20635
20637
20639
20641
20643
20645
20647
20649
20651
20653
20655
20657
21521

Number of
conductors &
cross-section
n x mm2

Nominal
outer
diameter
mm

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

8,5
10,0
13,0
15,5
18,5
20,0
23,0
24,0
25,5
27,5
29,5
33,5
9,0

75
120
135
215
330
380
480
545
620
700
805
1030
100

50
60
80
90
110
120
140
145
155
165
175
200
55

1x2x0,75
2x2x0,75 Quad
2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
1x2x1,5

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....


(Quad)cable is built up as a star quad
with the following identification
1 core
white
2 core
blue
3 core
white
4 core
blue

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

5/2014

Core identification

250V CABLES

RFA-FRHF 250V

250V CABLES

70

RFA-FRHF (i)

Fire-resistant collectively and


pair screened instrumentation
and communication cable 250V

5/2014

DESIGN:

STANDARDS:
IEC 60092-376, design

1. Conductor
- stranded copper conductor
IEC 60228, class 2
- tinned stranded copper conductor on request
2. Insulation
- Mica tape
- XLPE plastic
IEC 60092-351
3. Twisted pair & pair screen
- two insulated cores twisted together to form a pair
- plastic coated aluminium tape and a tinned copper drain wire
4. Bedding
- separator tape
5. Collective screen
- drain wire tinned copper
- aluminium polyester tape coverage 100 % IEC 60092-350
6. Sheath
- polyolefine plastic, SHF1, standard colour orange IEC 60092-359
- on request thermosetting polyolefine, SHF2, standard colour black
- other colours on request

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

Application: For fixed installation in most areas and on open deck in ships.
If the cable is exposed to direct sun light protective covering or
cable with black outer sheath is recommended.
Main characteristics
Rated voltage
Maximum conductor
temperature
Flame-retardant

150/250V (300V)
+ 90 C
IEC 60332-1-2
IEC 60332-3-22

-test for single insulated wire and cable


-test for bunched wires and cables,
category A

Fire-resistant
IEC 60331-1 or IEC 60331-2
Halogen-free
IEC 60754 series
Smoke emission
IEC 61034 series
For details see general information section
Electrical data
Loop resistance of pair, max. / +20C
Pair capacitance, nom. / 800Hz
Loop inductance, nom.
Insulation resistance / +20C

0,75mm2 1,5mm2
52
24,4
55
75
0,6
0,7
1500
1500

Unit
ohm/km
nF/km
mH/km
Mohm/km

Minimum recommended installation temperature -15 C


Lowest operation temperature -40 C
Identification: Lot number, cable type, cable size, voltage, temperature,
standards, production month, manufacturer's name and
meter marking printed on the sheath

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

71

Part number
20667
20669
20671
20673
20675
20677
20679
20681
20683
20685
21553
21555

Number of
conductors &
cross-section
n x mm2

Nominal
outer
diameter
mm

Approximate
weight kg/km

Min. bending
radius fixed
installation
mm

2x2x0,75
4x2x0,75
7x2x0,75
8x2x0,75
10x2x0,75
12x2x0,75
14x2x0,75
16x2x0,75
19x2x0,75
24x2x0,75
2x2x1,5
4x2x1,5

13,5
15,5
18,5
20,0
23,5
24,5
26,0
28,0
30,0
34,0
15,0
17,5

155
245
380
430
545
625
725
810
945
1205
215
350

80
95
110
120
140
145
155
165
180
205
90
105

250V CABLES

RFA-FRHF(i) 250V

Core identification

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

5/2014

Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....


The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)

OPTICAL FIBRE CABLE

72

FXMSU

Optical fibre
indoor/outdoor cable

Cable construction:
1. Central element glass fibre, 1,5 mm
2. PP-slotted core, 6,0 mm
3. Optical fibres, 250 m
4. Swellable tape
5. Rip cord

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant
(only SHF2)

5/2014

6. UV-protected and halogen free sheath

- non-metallic
- networks in marine applications
- Fibres: 250 m SM or MM fibres
- 4 - 48 fibres
Cable characteristics:
Maximum pulling force
Crush strength / 100 mm (plate)
Crush strength / 25 mm (mandrel)
Impact strength
Sheath marking
Minimum installation temperature
Operating temperature range
Longitudinal water tightness
Flame-retardant
Halogen-free
Smoke emission

500 N EN 187000 method 501


4000 N EN 187000 method 504
650 N EN 187000 method 504
25
J EN 187000 method 505
Cable type, manufacturer's name,
manufacturing number and time,
length marking in meter
-15 C
-45...+70 C
EN 187000 method 605B

.. Slotted core

cables have
blue and red
marker threads
for the first and
last slot
respectively.

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables,
category A
IEC 60754 series
IEC 61034 series

For details see general information section

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

73

Part
number

FXMSU 1X4SML (L)


FXMSU 1X6SML (L)
FXMSU 2X6SML (L)
FXMSU 4X6SML (L)
FXMSU 1X4OM3L (L)
FXMSU 2X4OM3L (L)
FXMSU 3X4OM3L (L)
FXMSU 4X6OM3L (L)
FXMSU 1X4GKL (L)
FXMSU 1X6GKL (L)
FXMSU 2X4GKL (L)
FXMSU 3X4GKL (L)
FXMSU 4X4GKL (L)
FXMSU 4X6GKL (L)
FXMSU1X4SML+1X4GKL (L)
FXMSU1X4SML+2X4GKL (L)
FXMSU2X4SML+2X4GKL (L)
FXMSU1X6SML+3X4GKL (L)
FXMSU2X6SML+3X4GKL (L)
FXMSU1X4SML+1X4OM3 (L)
FXMSU1X4SML+2X4OM3L (L)
FXMSU2X4SML+2X4OM3L (L)
FXMSU1X6SML+3X4OM3L (L)
FXMSU2X6SML+3X4OM3L (L)

Other fiber combinations on request


Part number for oil resistant SHF2 cable:
4 + code from above table 4xxxxx

Diameter
of slotted
core,
mm

Nominal Approximate Minimum bending radius


outer
weight,
during
final
diameter,
kg/km
installation, installation,
mm
mm
mm

9,4

75

140

100

5/2014

10001
10022
10024
10028
14384
14386
14388
14398
14404
14406
14408
14410
14412
14416
14420
14422
14424
14426
14428
14449
14450
14451
14454
14455

Cable and number of


fibres

OPTICAL FIBRE CABLE

FXMSU

OPTICAL FIBRE CABLE

74

FXMMS

Optical fibre
installation cable

Cable construction:

Flameretardant
Fireresistant
Halogenfree
Low smoke
emission
Oil resistant

1. FRP central element 2 mm


2. PP-slotted core
3. Installation cable unit FMS 1 (2 mm)
4. Fire barrier tape
5. Rip cord

(only SHF2)

5/2014

6. Halogen free sheath 1,5 mm

- For tray installation


- Fibres: 28 SM or MM fibres, 900 m
- Connectors can be mounted directly to the fibres
Cable characteristics:
Maximum pulling force
Crush strength / 100 mm (plate)
Crush strength / 25 mm (mandrel)
Impact strength, R = 300 mm
Sheath marking
Minimum bending radius
Nominal cable diameter
Cable weight
Minimum installation temperature
Operating temperature range

1500 N EN 187000 method 501


4000 N EN 187000 method 504
750 N EN 187000 method 504
30 J EN 187000 method 505
Cable type, manufacturer's name,
manufacturing number and time,
length marking in meter
195 mm during installation, 130 mm in final bending
13.1 mm
142 kg/km
-15 C
-45...+70 C

Flame-retardant

IEC 60332-1-2 -test for single insulated wire and cable


IEC 60332-3-22 -test for bunched wires and cables
category A

Halogen-free

IEC 60754 series

Smoke emission

IEC 61034 series

For details see general information section


Cable and number of
fibres

FXMMS 2-4

Diameter
of slotted
core,
mm
7,5

FXMMS 6-8

9,7

Nominal Approximate Minimum bending radius


outer
weight,
during
final
diameter,
kg/km
installation, installation,
mm
mm
mm
10,7
102
160
110
13,1

142

195

130

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

75

Part
number

10810
10812
10814
10816
13747
13748
13749
13750
13872
13874
13876
13878

Cable and number of


fibres

FXMMS 2SMT (2MM)


FXMMS 4SMT (2MM)
FXMMS 6SMT (2MM)
FXMMS 8SMT (2MM)
FXMMS 2GKT (2MM)
FXMMS 4GKT (2MM)
FXMMS 6GKT (2MM)
FXMMS 8GKT (2MM)
FXMMS 2OM3T (2MM)
FXMMS 4OM3T (2MM)
FXMMS 6OM3T (2MM)
FXMMS 8OM3T (2MM)

Nominal Approximate Minimum bending radius


outer
weight,
during
final
diameter,
kg/km
installation, installation,
mm
mm
mm
10,7
102
160
110
10,7
102
160
110
13,1
142
195
130
13,1
142
195
130
10,7
102
160
110
10,7
102
160
110
13,1
142
195
130
13,1
142
195
130
10,7
102
160
110
10,7
102
160
110
13,1
142
195
130
13,1
142
195
130

5/2014

Part number for oil resistant SHF2 cable:


4 + code from above table 4xxxxx

Diameter
of slotted
core,
mm
7,5
7,5
9,7
9,7
7,5
7,5
9,7
9,7
7,5
7,5
9,7
9,7

OPTICAL FIBRE CABLE

FXMMS

OPTICAL FIBRE CABLE

76

Cabled optical fibres characteristics


Fibre coating:

L = 250 m 10 m
T = 900 m 50 m

Single mode fibre

10/125 m

Fibre type

SML 250m10m
SMT 900m50m

5/2014

Mode field diameter (MFD)


Mode field eccentricity
-Installation cables
Cladding diameter
- Installation cables
Cladding ellipticity
Fibre attenuation

1310 nm

1310 nm
1550 nm

Zero dispersion range


Dispersion coefficient
- Dispersion at
Cut-off wavelength
- Installation cables
Polarization mode dispersion
Proof test
Fibre identification

Multi mode fibre

SM / OS2 (ITU-T G.652.D)

1550 nm

50/125 m

9,3 +/- 0,5 m


1,0 m
0,5 m
125 +/- 2 m
125 +/- 1 m
2%
0,40 dB/km
0,25 dB/km
1300...1324 nm
0,093 ps/nm2/km
18 ps/nm/km
1260 nm
1180...1250 nm
0,5 ps/km
1 % / 1 sec
6 colour system
according to SFS 5648

OM3

Fibre type

OM3L 250m10m
OM3T 900m50m

Core diameter
Core ellipticity
Core eccentricity
Cladding diameter
Cladding ellipticity
Fibre attenuation

50 +/- 3 m
6%
3 m
125 +/- 2 m
2%
2,7 dB/km
0,8 dB/km
1500 MHz x km (LED)
500 MHz x km (LED)
2000 MHz x km (Laser)
0,200 +/- 0,015
6 colour system
according to SFS 5648

Bandwidth

Numerical aperture, NA
Fibre identification

850 nm
1300 nm
850 nm
1300 nm
850 nm

Tel. +358 2 410 8700, fax +358 2237 2428, www.helkamabica.com

77

62,5/125 m

GK / OM1
GKL 250m10m
GKT 900m50m

Core diameter
Core ellipticity
Core eccentricity
Cladding diameter
Cladding ellipticity
Fibre attenuation

62,5 +/- 3 m
6%
3 m
125 +/- 2 m
2%
3,5 dB/km
1,0 dB/km
200 MHz x km
500 MHz x km
0,275 +/- 0,015
6 colour system
according to SFS 5648

Bandwidth
Numerical aperture, NA
Fibre identification

850 nm
1300 nm
850 nm
1300 nm

5/2014

Fibre type

OPTICAL FIBRE CABLE

Multi mode fibre

TECHNICAL INFORMATION

78

GENERAL INFORMATION
Insulation material:
The following designations are used for
insulation materials in this catalog.
All materials are halogen-free.

The designation SHF1 stands for thermoplastic compound. This material is


halogen-free, highly flame-retardant and
has low smoke emission.

5/2014

The designation SHF2 stands for oil


resistant thermosetting compound. This
material is halogen-free, highly flameretardant and has low smoke emission.

Definition of terms:
Oil resistance
Sheathing material is oil resistant
according to method IEC 60811-2-1 and
requirements from IEC 60092-359/SHF2.
The oil resistance is demonstrated by
immersion in IRM902 oil for 24h at
100C.

4m

2.5 m

Sheathing material:

Test on
bunched
cables
IEC 60332-3
Burning is
allowed up
to max. 2.5
meters from
the burner
within
specified time.

Halogen-free
Halogen-free refers to the absence
of halogens, such as chlorine and
fluorine, and is determined on
the basis of halogen content and
the acidity of gases of a cable.
3.5 m

XLPE stands for cross-linked polyethylene compound. It has excellent


mechanical and electrical characteristics.

All Helkama cables comply with the most


severe requirements of
category A.

1m

2m

IEC 60332-1 is the test for single insulated wire and cable. Test procedure and
requirements according to the picture
below.

50 mm

475
mm

Category

Amount of
burning
material

Burning time

7 litres/m

40 min

3,5 litres/m 40 min

1,5 litres/m 20 min

IEC 60754-2 determines the


degree of acidity of gases evolved
during combustion. The limit
values are 4,3 for pH and
10 mikroS for conductivity.
Smoke emission
Smoke emission refers to visibility
in a fire. The greater the light transmittance, the better the visibility.
When tested in accordance with
IEC 61034-1 (test method) and
IEC 61034-2 (test requirements)
the smoke emission of a cable during
fire must not exceed the following values.

550 600
mm mm

Flame-retardant
To be flame-retardant, the cables
must withstand the test specified in
IEC standard 60332-3 or IEC 60332-1.
Flame-retardant cables do not propagate
fire, and are self-extinguishing.
IEC 60332-3 is the test for bunched wires
and cables and has three categories A,
B and C, defined by different limits for
flammable material and burning times.
Burning time describes how long the
burner is directed towards the bunch of
cables. The requirement for passing the
test is that after the burner has been
removed the cables must extinguish
themselves. Burning may not occur more
than 2.5 m from the burner as shown in
the figure.

IEC 60754-1 determines the


halogen content of the material.
To meet the requirements as
halogen-free the halogen content
of the material may not exceed
0,5 % or 5 mg/g.

27m3 cube
smoke chamber

Min. 50 mm of the cable, measured from


the upper support, must remain unburned
after the specified time.

Requirements:
60 % light
transmittance

Un

3A

Fire-resistant
IEC 60331-1 Test method for fire with
shock at a temperature of at least
830 C for 90 minutes for cables of rated
voltage up to and including 0,6/1,0 kV
and with an overall diameter exceeding
20 mm.
IEC 60331-2 Test method for fire with
shock at a temperature of at least
830 C for 90 minutes for cables of rated
voltage up to and including 0,6/1,0 kV
and with an overall diameter not
exceeding 20 mm.

830 C / 90 min

gas burner
500 mm

110 mm

79

Recommended minimum bending


radius, ( R ) :

Radius (R)
Outer
diameter (D)

DIAMETER TOLERANCE

During installation
During installation
Fixed installation
Fixed installation

R = 6x D
R = 9x D
R = 4x D
R = 6x D

LKSM-HF
LKSM-EMC
LKSM-VFD
LKMSM-HF
LKAM-HF
LKM-FRHF
LKSM-FRHF
LKAM-FRHF
RFE-HF
RFE-HF(i)
RFA-HF
RFA-HF(i)
RFE-FRHF
RFE-FRHF(i)
RFA-FRHF
RFA-FRHF(i)

During installation
Fixed installation

R = 9x D
R = 6x D

Tolerance
0,5mm
1,0mm
1,5mm

Cable outer diameter, mm.


30,1 40
40,1 50
50,1 60

Tolerance
2,0mm
2,5mm
3,0mm

CORE IDENTIFICATION (according to HD 308 S2)


250V
Pair number
1
2
3
4
5
6

0,6/1kV
a

1
3
5
7
9
11

2
4
6
8
10
12

Normal type

1-core

BK

2-cores

BN BU

3-cores

BN BK

4-cores

etc.
5-cores

GY

Y/G BU
BN

BU BN

Y/G BN

GY BK

GY BK

Y/G
BU
GY
BN
BK

Y/G

5
4

250V
LKSM-HF

7-cores
and above

2-cores

G-type
(with earth
conductor)

2
7
6

1
5

Black numbers
on white base

2
1

3
4

Black numbers
on white base
Last core
yellow/green.

Black numbers on white base

BU = Blue, BN = Brown, BK = Black, GY = Grey, Y/G = Yellow/Green

3-cores

2
3

1,8/3kV

LKSM-VFD

1-core

BK

3-cores

BN BK

Black numbers on white base

4-cores
to 37-cores

GY
Black numbers on white base

3-cores
+ 3-ground
cores

Y/G

BN BK
Y/G

GY

Y/G

5/2014

Cable outer diameter, mm.


1 10
10,1 20
20,1 30

< 25mm
> 25mm
< 25mm
> 25mm

TECHNICAL INFORMATION

BENDING RADIUS

LKM-HF
LKMM-HF
LKEM-HF

TECHNICAL INFORMATION

80

CURRENT RATING
"Current rating (A) at an ambient temperature of 45C
according to the standard IEC 60092-352
0,6/1 kV +90C marine cables."
Current carrying capacities in continous service at
maximum rated conductor temperature of +90C.
For class 2 conductor cables
Size

10

12

14

16

19

24

27

37

1
18
23
30
40
52
72
96
127
157
196
242
293
339
389
444
522
601

0,85
15
20
26
34
44
61
82
108
133
167
206
249
288
331
377
444
511

0,7
13
16
21
28
36
50
67
89
110
137
169
205
237
272
311
365
421

0,7
13
16
21
28
36
50
67
89
110
137
169
205
237
272
311
365
421

0,58
10
13
17
23
30
42
56
74
91

0,52
9
12
16

0,46
8
11
14

0,44
8
10
13

0,41
7
9
12

0,40
7
9
12

0,37
7
9
11

0,35
6
8
11

0,33
6
7
10

0,30
5
7
9

10

12

14

16

19

24

27

37

1,5mm2
2,5mm2
4mm2
6mm2
10mm2
16mm2
25mm2
35mm2
50mm2
70mm2
95mm2
120mm2
150mm2
185mm2
240mm2
300mm2

1
17
22
30
39
50
71
94
123
153
196
240
284
331
381
429
507
582

0,85
14
19
26
33
43
60
80
105
130
167
204
241
281
324
365
431
495

0,7
12
15
21
27
35
50
66
86
107
137
168
199
232
267
300
355
407

0,7
12
15
21
27
35
50
66
86
107
137
168
199
232
267
300
355
407

0,58
10
13
17
23
29
41
55
71
89

0,52
9
11
16

0,46
8
10
14

0,44
7
10
13

0,41
7
9
12

0,40
7
9
12

0,37
6
8
11

0,35
6
8
11

0,33
6
7
10

0,30
5
7
9

Ambient temperature
Correction factor

+35C
1,10

Factor, n

5/2014

For continuous service. Continuous service for a cable is


to be considered as a current-carrying service (with
constant load) having a duration longer than three times
the thermal time constant of the cable, i.e. longer than
the critical duration(see short time duty).

1,0mm2
1,5mm2
2,5mm2
4mm2
6mm2
10mm2
16mm2
25mm2
35mm2
50mm2
70mm2
95mm2
120mm2
150mm2
185mm2
240mm2
300mm2

For class 5 conductor cables


Size

N
Factor, n

1,0mm2

+40C
1,05

+45C
1,00

+50C
0,94

+55C
0,88

+60C
0,82

+65C
0,74

+70C
0,64

+75C
0,58

+80C
0,47

81

SHORT CIRCUIT CURRENT

Based on formula:

Ik = 226

S
t

S
t

In

234 + Tk
234 + Tb

Formula 1:

Ik = 146
Ik
S
t
Tk

=
=
=
=

Maximum permissible short circuit current.


Cross-section of the conductor in mm2.
Duration of the short circuit in s.
Maximum rated conductor temperature,
short circuit, C
Tb = Maximum rated conductor temperature,
normal, C
Formula 1: For 0,6/1kV cable with XLPE or HF90 with
maximum operating temperature of +90C (Tb) and
short circuit temperature of +250C (Tk).

Cross-section of
the conductor
in mm2
1,0
1,5
2,5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

0,2
0,3
0,5
0,8
1,3
2,0
3,3
5,2
8,2
11,4
16,3
22,9
31,0
39,2
49,0
60,4
78,4
97,9

0,5
1
2
3
0,2 0,1 0,1 0,1
0,3 0,2 0,2 0,1
0,5 0,4 0,3 0,2
0,8 0,6 0,4 0,3
1,2 0,9 0,6 0,5
2,1 1,5 1,0 0,8
3,3 2,3 1,7 1,3
5,2 3,7 2,6 2,1
7,2 5,1 3,6 3,0
10,3 7,3 5,2 4,2
14,5 10,2 7,2 5,9
19,6 13,9 9,8 8,0
24,8 17,5 12,4 10,1
31,0 21,9 15,5 12,6
38,2 27,0 19,1 15,6
49,6 35,0 24,8 20,2
61,9 43,8 31,0 25,3
Short circuit current in kA

10
0,0
0,1
0,1
0,2
0,3
0,5
0,7
1,2
1,6
2,3
3,2
4,4
5,5
6,9
8,5
11,1
13,9

5/2014

SHORT CIRCUIT FACTOR


Short Circuit Factor can be calculated by following formula:

SHORT CIRCUIT FACTOR =

Duration of the short circuit in s.

TECHNICAL INFORMATION

Maximum permissible short circuit current.


0,6/1 kV +90C marine cables.

SHORT CIRCUIT CURRENT


CURRENT RATING

TECHNICAL INFORMATION

82

SHORT TIME DUTY


Short time duty according to the standard
IEC 60092-352 0,6/1 kV +90C
marine cables.
If a cable is intended to supply motor
or equipment operating for periods of half an hour or
one hour, its current rating given in table current
rating, may be increased using the relevant
correction factors given by formula:

correction =
factor

1,12
1-exp(-ts/T)

( ts = service time, min. T = Time constant, min.)

T = 0,245 x d 1,35

5/2014

(d = Overall diameter of the cable, mm.)

Overall
diameter of
the cable,
mm.

Service
time, min.

1
2
3
4
5
6
7
8
9
10
20
30
40
50
60

Time
Critical
constant, duration,
min.
min.

30

60

3x T

1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,059
1,059
1,061
1,126
1,255
1,403
1,554
1,705

1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,058
1,066
1,105
1,173
1,254
1,341

0,245
0,625
1,08
1,59
2,15
2,75
3,39
4,06
4,76
5,48
14,0
24,2
35,6
48,2
61,6

0,735
1,87
3,24
4,78
6,46
8,26
10,2
12,2
14,3
16,5
41,9
72,5
107
145
185

Correction factor.

Intermittent service
Correction factor for intermittent service
according to the standard IEC 60092-352
The correction factor given hereby has been
roughly calculated for periods of 10 min,
of which 4 min are with a constant load and
6 min without load.
Intermittence period = 10min.
Intermittence ratio = 40%.

Fi=

1-exp(-10/T)
1-exp(-4/T)

Overall diameter of
the cable, mm.

Correction
factor.

1
2
3
4
5
6
7
8
9
10
20
30
40
50
60

1,000
1,001
1,012
1,042
1,083
1,127
1,170
1,208
1,242
1,273
1,433
1,490
1,518
1,534
1,544

83

VOLTAGE DROP

Size

1.0mm2
1.5mm2
2.5mm2
4mm2
6mm2
10mm2
16mm2
25mm2
35mm2
50mm2
70mm2
95mm2
120mm2
150mm2
185mm2
240mm2
300mm2

Resistance
at +20C
ohm/km

Resistance
at +90C
ohm/km

Voltage
reduction
mV/Am *)

Resistance
at +45C
ohm/km

Current
rating
A **)

Voltage
reduction
mV/m ***)

18,1
12,1
7,41
4,61
3,08
1,83
1,15
0,727
0,524
0,387
0,268
0,193
0,153
0,124
0,0991
0,0754
0,0601

23,1
15,4
9,45
5,88
3,93
2,33
1,47
0,927
0,668
0,493
0,342
0,246
0,195
0,158
0,1264
0,0961
0,0766

46,2
30,9
18,9
11,8
7,85
4,67
2,93
1,85
1,34
0,987
0,683
0,492
0,390
0,316
0,253
0,192
0,153

19,9
13,3
8,14
5,06
3,38
2,01
1,26
0,798
0,575
0,425
0,294
0,212
0,168
0,136
0,1088
0,0828
0,0660

18
23
30
40
52
72
96
127
157
196
242
293
339
389
444
522
601

0,72
0,61
0,49
0,41
0,35
0,29
0,24
0,20
0,18
0,17
0,14
0,12
0,11
0,11
0,097
0,086
0,079

Size

0,75mm2
1.0mm2
1.5mm2
2.5mm2
4mm2
6mm2
10mm2
16mm2
25mm2
35mm2
50mm2
70mm2
95mm2
120mm2
150mm2
185mm2
240mm2
300mm2

Resistance
at +20C
ohm/km

Resistance
at +90C
ohm/km

Voltage
reduction
mV/Am *)

Resistance
at +45C
ohm/km

Current
rating
A **)

Voltage
reduction
mV/m ***)

26,0
19,5
13,3
7,98
4,95
3,30
1,91
1,21
0,78
0,554
0,386
0,272
0,206
0,161
0,129
0,106
0,0801
0,0641

33,2
24,9
17,0
10,18
6,31
4,21
2,44
1,54
0,995
0,706
0,492
0,347
0,263
0,205
0,164
0,135
0,102
0,082

66,3
49,7
33,9
20,4
12,6
8,42
4,87
3,09
1,99
1,41
0,984
0,694
0,525
0,411
0,329
0,270
0,204
0,163

28,6
21,4
14,6
8,76
5,44
3,62
2,10
1,33
0,857
0,608
0,424
0,299
0,226
0,177
0,142
0,116
0,088
0,070

14
17
22
30
39
50
71
94
123
153
196
240
284
331
381
429
507
582

0,80
0,73
0,64
0,53
0,42
0,36
0,30
0,25
0,21
0,19
0,17
0,14
0,13
0,12
0,11
0,10
0,09
0,08

Cable types: LKSM-HF 250V, RFE-HF, RFE-HF(i), RFA-HF, RFA-HF(i), RFE-FRHF, RFE-FRHF(i), RFA-FRHF, RFA-FRHF(i)
Size

0,5 mm2
0,75 mm2
1,5 mm2

Resistance
at +20C
ohm/km

Maximum
conductor
temperature, C

Resistance
at +45C
ohm/km

Voltage
reduction
mV/Am at +45C

Resistance
at +90C
ohm/km

Voltage
reduction
mV/Am at +90C

40,4
26,0
12,8

90
90
90

44,4
28,6
14,1

88,7
57,1
28,1

51,5
33,2
16,3

103,0
66,3
32,6

*) at +90C
**) For continuous service (single core, ambient temperature +45C)
***) at maximum current rating for continuous service at +45C

5/2014

Cable types: LKM-HF FLEX, LKSM-HF FLEX, LKEM-HF (Cables with class 5 conductor)

TECHNICAL INFORMATION

Cable types: LKM-HF, LKSM-HF, LKAM-HF, LKM-FRHF, LKSM-FRHF (Cables with class 2 conductor)

HELKAMA BICA OY
Lakimiehenkatu 4
FI-20780 KAARINA
Finland
Tel. +358 2 410 8700
Fax +358 2237 2428
firstname.lastname@helkamabica.fi

sales@helkamabica.fi

Helkama Bica (Shanghai) Co., Ltd.


Plot 1-2, MinHang Export Processing Zone
No. 3111 Huan Cheng West Road
Fengxian District, Shanghai 201401,
China
Tel. +86 21 3365 5333,
Fax +86 21 3365 5331

sales@helkamabica.cn

www.helkamabica.com

5/2014 Subject to change without prior notice. See latest updates on our webpage www.helkamabica.com