You are on page 1of 12

AB - Blocked Alarms Handling

DN985508
Issue 6B-0

Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of
its products and services. We would like to encourage you as our customers and users to join
us in working towards a cleaner, safer environment. Please recycle product packaging and
follow the recommendations for power use and proper disposal of our products and their components.
If you should have questions regarding our Environmental Policy or any of the environmental
services we offer, please contact us at Nokia Siemens Networks for any additional information.

AB - Blocked Alarms Handling

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2012/1/28. All rights reserved

Important Notice on Product Safety


This product may present safety risks due to laser, electricity, heat, and other sources
of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle
this product and only after having carefully read the safety information applicable to this
product.
The safety information is provided in the Safety Information section in the Legal, Safety
and Environmental Information part of this document or documentation set.

The same text in German:

Wichtiger Hinweis zur Produktsicherheit


Von diesem Produkt knnen Gefahren durch Laser, Elektrizitt, Hitzeentwicklung oder
andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch
geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheitsanforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter Sicherheitshinweise im Teil Legal,
Safety and Environmental Information dieses Dokuments oder dieses Dokumentationssatzes.

Id:0900d80580274c35

DN985508
Issue 6B-0

AB - Blocked Alarms Handling

Table of Contents
This document has 12 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AB - BLOCKED ALARMS HANDLING . . . . . . . . . . . . . . . . . . . . . . . . . . 6
AB - BLOCKED ALARMS HANDLING . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ABB BLOCK ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
ABU UNBLOCK ALARMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ABO OUTPUT BLOCKED ALARMS . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

DN985508
Issue 6B-0

Id:0900d80580274c35

AB - Blocked Alarms Handling

Id:0900d80580274c35

DN985508
Issue 6B-0

AB - Blocked Alarms Handling

Summary of changes

Summary of changes
Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
Changes made between issues 6A and 6
The new layout checked.
Changes made between issues 6 and 5
The section OPERATION has been removed. The layout of the document has been
modified, the parameter explanations clarified and explanations of the execution error
messages added.
Changes made between issues 5 and 4
The layout of the document has been updated.
Changes made between issues 4 and 3
ABO

OUTPUT BLOCKED ALARMS


The execution printout has been modified.

DN985508
Issue 6B-0

Id:0900d8058045ac33

AB - BLOCKED ALARMS HANDLING

AB - Blocked Alarms Handling

AB - BLOCKED ALARMS HANDLING


With the commands of this command group you can block the effect of an alarm to the
system, remove alarm blocking and display the blocked alarms.
A blocked alarm has no effect on the system's maintenance actions, that is, it does not
activate the recovery or the fault diagnosis. Neither is the alarm printed out locally on the
alarm output device nor sent to the operation and maintenance centre.
Menu of the
command group:

BLOCKED ALARMS HANDLING COMMANDS

?
B:
U:
O;
Z;

.....
.....
.....
.....
.....

DISPLAY MENU
BLOCK ALARM
UNBLOCK ALARMS
OUTPUT BLOCKED ALARMS
RETURN TO MAIN LEVEL

Id:0900d80580342e93

DN985508
Issue 6B-0

AB - Blocked Alarms Handling

AB - BLOCKED ALARMS HANDLING

AB - BLOCKED ALARMS HANDLING


The commands in this command group are:

DN985508
Issue 6B-0

ABB

BLOCK ALARM

ABU

UNBLOCK ALARMS

ABO

OUTPUT BLOCKED ALARMS

Id:0900d805802a412f

ABB BLOCK ALARM

AB - Blocked Alarms Handling

ABB BLOCK ALARM


Function

With this command you can block alarms. The alarm is specified on the basis of the
alarm number. The object unit can be defined so that the alarm is blocked when its
object unit is any unit, any unit of a given unit type, or one specific unit.

Parameters

alarm number: unit type, stage, pair, unit index;

Syntax

ABB: [ <alarm number> | <all> def ]:


[ <unit type> | <all> def ],
[ [ <stage> | <pair> ] | <all> def ],
[ <unit index> | <all> def ];

Parameter explanations

alarm number
This parameter identifies the number of the alarm to be blocked. The default is all
alarms. If you use the default, you must identify the object unit in the second parameter
block.
unit type
This parameter identifies the type of the object unit of the alarm. The default value is all
unit types.
stage
This parameter is used, when necessary, for defining the stage of the object unit of the
alarm that you want to block. The default is all stages.
pair
This parameter is used, when necessary, for defining the pair number of the object unit
of the alarm that you want to block.
unit index
This parameter is used for defining the index of the object unit of the alarm that you want
to block. The default is all indexes, that is, all units of the unit type that you have identified with unit type parameter and, when needed, with stage or pair parameter.
If you use the default value in this second parameter block, you must enter alarm
number parameter in the first parameter block.

Examples

1. To block alarm 1623 that has the OMU as the object unit, supply the command
ABB: 1623:OMU;

Semantic error
messages
Execution error
messages

In error situations, the general semantic error messages of MML commands will be
output.
/*** ACCESS OF ALBLOC FILE FAILED ***/
The program block ALARMP failed in handling the ALBLOC file. Check the live alarms
concerning the file system and proceed as instructed in the description of the alarm(s)
in question in alarm instructions.
/*** ALARM ALREADY BLOCKED ***/
The alarm has already been blocked.
/*** ALBLOC FILE IS FULL ***/

Id:0900d805803211eb

DN985508
Issue 6B-0

AB - Blocked Alarms Handling

ABB BLOCK ALARM

The blocked alarm file is full. Remove unnecessary alarm blockings and give the
command again.
/*** DISK UPDATING FAILED ***/
The disk updating of the ALBLOC file requested from the FLSSEB service block failed.
/*** FILE DISTRIBUTION ERROR ***/
The distribution of ALBLOC file requested from the FLSSEB service block failed.
/*** NONEXISTENT ALARM ***/
The alarm system does not recognise the alarm number that you have given in the
command. Try again with the correct alarm number.
In addition, the general execution error messages of MML commands are used.

DN985508
Issue 6B-0

Id:0900d805803211eb

ABU UNBLOCK ALARMS

AB - Blocked Alarms Handling

ABU UNBLOCK ALARMS


Function

With this command you can remove alarm blocking.

Parameters

alarm number: unit type, stage, pair, unit index;

Syntax

ABU: [ <alarm number> | <all> def ]:


[ <unit type> | <all> def ],
[ [ <stage> | <pair> ] | <all> def ],
[ <unit index> | <all> def ];

Parameter explanations

alarm number
This parameter identifies the number of the alarm to be unblocked. The default is all
alarms.
unit type
This parameter identifies the type of the object unit of the alarm to be unblocked. The
default value is all unit types.
stage
This parameter is used, when necessary, for defining the stage of the object unit of the
alarm to be unblocked. The default is all stages.
pair
This parameter is used, when necessary, for defining the pair number of the object unit
of the alarm to be unblocked. The default is all pairs.
unit index
This parameter is used for defining the index of the object unit of the alarm to be
unblocked. The default is all indexes, that is, all units of the unit type that you have identified with unit type parameter and, when needed, with stage or pair parameter.

Examples

1. To unblock all alarms, supply the command


ABU;
2. To unblock alarm 1623 directed to the OMU, supply the command
ABU:1623:OMU;

Semantic error
messages
Execution error
messages

In error situations, the general semantic error messages of MML commands will be
output.
/*** ACCESS OF ALBLOC FILE FAILED ***/
The program block ALARMP failed in handling the ALBLOC file. Check the live alarms
concerning the file system and proceed as instructed in the description of the alarm(s)
in question in the Alarm Reference Manual.
/*** ALARM NOT BLOCKED ***/
The alarm has not been blocked.
/*** DISK UPDATING FAILED ***/
The disk updating of the ALBLOC file requested from the FLSSEB service block failed.
/*** FILE DISTRIBUTION ERROR ***/

10

Id:0900d805803b130a

DN985508
Issue 6B-0

AB - Blocked Alarms Handling

ABU UNBLOCK ALARMS

The distribution of the ALBLOC file requested from the FLSSEB service block failed.
/*** NONEXISTENT ALARM ***/
The alarm system does not recognise the alarm number that you have given in the
command. Try again with the correct alarm number.
In addition, the general execution error messages of MML commands are used.

DN985508
Issue 6B-0

Id:0900d805803b130a

11

ABO OUTPUT BLOCKED ALARMS

AB - Blocked Alarms Handling

ABO OUTPUT BLOCKED ALARMS


Function

With this command you can display the data on the alarm blockings that are active. The
printout shows all the alarms that have been blocked and their object units.

Parameters

The command has no parameters.

Syntax
Examples

ABO;
1. To display the blocked alarms, supply the command
ABO;

Execution printouts

The execution printout of example 1 is as follows:


DX 220
DX220-LAB
BLOCKED ALARMS

1998-01-26

ET-12
LPT

ALL ALARMS
ALL ALARMS

1018
2018

PROGRAM BLOCK COMMUNICATION ERROR


DYNAMIC FLAGPOOL FULL

18:20:30

ALL UNITS
OMU

COMMAND EXECUTED
Execution error
messages

/*** ACCESS OF ALBLOC FILE FAILED ***/


The ALARMP program block failed in handling the ALBLOC file. Check the live alarms
concerning the file system and proceed as instructed in the description of the alarm(s)
in question in alarm instructions.
In addition, the general execution error messages of MML commands are used.

12