You are on page 1of 55

SCHEDULE OF RATES FOR

B U I L D I N G W O RK S I N
SARAWAK 2014

JKR Sarawak
December 2014

Notes to tenderers:
1.

This is only a cover page for this document. Please obtain the full set from
the JKR Sarawak webpage or any JKR Sarawak office.

2.

The Location Factor from base at Kuching City for this tender is ____ %
and is the percentage over all the items and rates as listed in this Schedule of
Rates to be used for the purposes as stated in the tender documents.

3.

Any attempt to amend / change / correct etc. this percentage by the


tenderer shall cause the tender to be disqualified.

L O C AT I O N F AC T O R FR O M B A S E AT K U CH I N G CI T Y
(To be read together with the Rules of determining the Location Factor)
Kuching

Samarahan

Betong

Kapit

City

0%

Padawan

District

15%

2%

Lubok Antu

20%

Santubong

3%

Lingga

20%

Siburan

3%

Pantu

13%

Bau

5%

Engkilili

18%

Lundu

8%

Sematan

9%

Skrang

15%

District

2%

District

12%

Serian

5%

Kem Bt 10 & 14

13%

Simunjan

12%

Durin

15%

Sebuyau

15%

Bawang Assan

13%

Asajaya

10%

Sungai Assan

13%

Sadong Jaya

12%

Kanowit

16%

Tebedu

8%

Machan

16%

Tebakang

8%

Nibong Tada

15%

Balai Ringin

8%

Nanga Tada

17%

Nanga Dap

20%

Nanga Ngemah

20%

Sri Aman

Sibu

District

20%

Nanga Ngungun

20%

Spaoh

20%

Nanga Poi

22%

Debak

20%

Nanga Jagau

40%

Pusa

21%

Selangau

18%

Beladin

20%

Ulu Balingian

20%

Maludam

22%

Arip

22%

Saratok

20%

Stapang

16%

Roban

20%

Rassau

22%

Kabong

20%

District

30%

District

15%

Song

25%

Tatau

20%

Belaga

70%

Sebauh

23%

Sungai Asap

25%

Bintulu

L O C AT I O N F AC T O R FR O M B A S E AT K U CH I N G CI T Y
(To be read together with the Rules of determining the Location Factor)
Mukah

Sarikei

District

20%

City

15%

Dalat

20%

Subis

15%

Oya

20%

Bekenu

15%

Igan

18%

Marudi

25%

Balingian

23%

Long Lama

40%

Kuala Balingian

23%

Beluru

22%

Semop

30%

Matu

25%

District

30%

Betanak

30%

Lawas

28%

Daro

25%

Bruit

30%

Tanjung Manis

18%

District

18%

Bintangor

18%

Pakan

20%

Selalang

20%

Julau

20%

Meluan

22%

Ulu Entabai

23%

Engkamop

30%

Nanga Wak

15%

Nanga Entabai

14%

Miri

Limbang

R U L E S O F DE T E R MI NI NG T H E L O C AT I O N FA C T O R
1.

The % factors as stated are for those projects accessible by motorized vehicles within
15km radius from the location shown.

2.

Where the project site is beyond 15km radius of the above stated locations, these
additional % factors shall be added on to those percentages stated above:
% addition
(i)
( ii )
( iii )
( iv )
(v)

3.

> 15km
> 45km
> 90km
> 135km
> 180km

< 45km
< 90km
< 135km
< 180km
< 220km

5%
10%
15%
20%
25%

Where the project sites are accessible only by waterway


(i)
( ii )
( iii )
( iv )
(v)
( vi )

areas within 15 km radius


areas within 30 km radius
areas within 60 km radius
areas within 90 km radius
areas within 120 km radius
areas within 150 km radius

0%
5%
10%
15%
20%
25%

4.

Where the project sites can only be accessible by air, the location factor shall be doubled
over the value obtained from that by motorized vehicles.

5.

Where the project sites can only be accessible by foot, the location factor shall be 50%
over the value obtained from that by authorized vehicles

6.

Where in determining the locations factor and two or more factors and radial distances
are equally applicable, the lower in each case shall be used.

7.

Where in determining the location factor and two or more factors and radial distances
by the rules above whereby there can be a combination due to accessibility, say partly
land and partly waterway or partly waterway and partly by foot, there shall be a
combination of the rules according to the radial distance from the nearest locations
stated above.

8.

Where in determining the location factor and the Site for the project lies within two
more radial distances, the addition % for the radial distance within which more than
50% of the Site lies shall be used.

P R E AM B L E S
1. All rates shall be used and read together with the Location Factor from base
at Kuching City.
2. All descriptions are to be read with reference to the General Specification for
Building Works (Latest Version) and the following:
(A) Piling
Rates for driving of precast concrete piles and reinforced concrete lengthened piles shall
include for the provision of all necessary mechanical plant, rig, temporary works, etc.
and for the travelling of pile frame about the site.
(B) Site Clearance And Earthwork
All rates herein shall be held to include for supply and delivery to site, wastage on
materials, carriage and cartage, carrying in and return of empties, hoisting, setting,
fitting and fixing in position, making good and all other labours and everything else
necessary (including any custom duties, etc.) for the proper completion of each item and
for establishment charges and profit.
Rates for site clearance shall include:
(a)
(b)
(c)
(d)

(e)
(f)

Clearing all general vegetation, tall grass, lallang, creepers, shrubs, bushes and
all undergrowth.
Felling of trees of all sizes including cutting, grubbing up their stumps and roots
and dispose off site.
Clearing all rubbish, debris and unwanted materials.
Breaking up and removing disused structures, surface beds and pavings, sewers,
drains and drain pipes, manholes, underground wells, sumps, fencing, posts,
retaining walls and other such like structures, including disconnecting and
sealing off services, plugging any pipes cut off at perimeter of site.
Removing existing tree stumps and grubbing up their roots and disposal off site.
Filling holes and voids caused by removal of trees, tree stumps, roots, existing
structures or obstructions with hardcore or suitable approved materials.

SOR for Building Works 2014

(C) Excavation
i.

Excavation shall be measured to commence at existing ground level. All excavation


and filling shall be measured nett. The quantities of excavation and filling shall be
measured on the assumption that the gradient of the existing surfaces between the
nearest adjacent spot levels and / or between contours is constant. Boulders not
exceeding one cubic metre shall be deemed to be included in the rates for excavation.
Rates for excavation (including excavation of drainage) are to include:
(a)
(b)

(c)
(d)
(e)
(f)
(g)
(h)
(i)
(j)

keeping all excavations free from water, mud, etc. by pumping or bailing if
required
planking and strutting, leveling, ramming or preparing bottoms, any double
handling required and for additional excavation for planking, strutting and
formwork
excavating by hand or mechanical means in various soil strata and water tables
multiple handling
protection of all services encountered
additional excavation and backfilling due to Contractors method or process
such as excavation for working space
reinstating to original condition all work disturbed by excavation
additional concrete infill where excavated below correct levels
giving all required notice
to ensure safety of excavation and adjoining structures.

(D) Concrete Work


i.

No allowance shall be made in the weight of steel reinforcement for rolling margin,
trying wires, spacers, chairs and weight of weld etc. Concrete shall be measured nett
without deduction for the volume of reinforcement.
Rates for concrete shall be held to include:
(a)
(b)
(c)
(d)
(e)
(f)
(g)

forming, leaving or cutting grooves, chases, mortices, holes


making good and any sundry items of alike nature
providing trial mixes, tests on materials and finished product, including non
destructive test on and off-site
hoisting or pumping or placing in position
compacting by suitable means
laying in bays and associated works
curing and protection.

Rates for precast concrete work shall include:


(a)
(b)
(c)
(d)
(e)
(f)

all reinforcement and moulds


lifting hooks, cast-in brackets, dowels and their fixing devices
finishing fair on all exposed faces, and other surface treatment to receive other
finishes
holes, sleeve, rates, notchings, sinkings, mortices and the like
temporary supports
hoisting and placing in position; setting, bedding, jointing and pointing in
cement mortar; cutting off lifting hooks.

SOR for Building Works 2014

Rates for bar reinforcement shall include:


(a)
(b)
(c)
(d)
(e)
(f)
(g)

allowance for rolling margin and weight of welds


cleaning by wire brushing or sand blasting
cutting to length and fabricating including bending to various bend and radii
providing and tying with galvanized steel wire at all intersections
providing seating or spacer blocks and chairs
providing all necessary laps and anchorages
submitting manufacturers mill and test certificate.

Rates for fabric reinforcement shall include:


(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)

allowance for rolling margin and weight of welds


cleaning by wire brushing or sand blasting
cutting to length and fabricating including bending to various bend and radii
providing and tying with galvanized steel wire at all intersections
providing seating or spacer blocks and chairs
providing all necessary laps and anchorages
submitting manufacturers mill and test certificate
straight, circular or raking cutting and notching.

ii. Sawn formwork shall mean formwork to produce concrete surfaces suitable for
plastering or tiling. Wrot formwork shall means formwork to produce fair face
concrete surfaces suitable for direct application of decorations. Formwork shall be
deducted for openings over one square metres.
Rates for formwork shall be held to include:
(a)
(b)
(c)
(d)
(e)
(f)

for erection, raking and circular cutting, splayed edges, notchings,


allowance for overlaps and passing at angles, battens, strutting, bolting,
wedging,
easing, striking and removal.
batten framing
stopping all holes, cracks and crevices
mould oil

(E) Brickwork and Blockwork


Rates for brickwork and blockwork shall be held to include:
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(j)
(k)
(l)
(m)
(n)

for all rough and fair cutting,


oversailing and receding courses
rough relieving and discharging arches
wedging and pinning
raking out joints for and pointing flashings
bedding plates
bedding and pointing frames
parging and coring flues
labour eaves filling
plumbing angles
forming square and rebated reveals, cut squints or bird-mouths, notches
forming, leaving or cutting chases, holes and mortices
cutting and pinning
making good any other sundry items of alike nature

SOR for Building Works 2014

(o)
(p)
(q)
(r)

all staging working platform


wetting bricks and blocks before laying
reinforcement and bonding tie
raking out joints for flashings, roof coverings, etc. and pointing with
mortar
(s) forming and pinning and / or building in frames, lintels, plugs, bolts,
anchors, metal window and doors, etc.
(t) forming opening in walls for building in air-brick, ventilation grating and
the like
(u) all necessary templates for curved or circular work
(v) filling ends of hollow blocks or providing special blocks with solid ends
all special make blocks
(w) cleaning down exposed faces
(x) sundry items of a like nature
Rates for facing brickwork shall further include for pointing, opening and closing
perpends, cutting with mechanical saws and providing sample panels as directed by the
S.O.
Rates for new brickwork and blockwork to existing structures shall further include for
hacking up and preparing existing floor, wall and ceiling finishes to receive new work,
cutting and pinning ends to existing brickwork or blockwork or concrete and any sundry
items of a like nature and for making good all work disturbed to match existing.
Rates for damp proof course shall include all laps, angles, waste cutting, labour and
materials required in laying and pointing exposed edges.

(F) Roofing
All roofing tiles and decking, sisalation, waterproofing works and the like shall be
measured nett.
Rates for roofing tiles and decking shall include:
(a) End laps and side laps.
(b) All straight, skew and circular cutting at eaves, verges, top edges, abutments,
valleys, hips and the like.
(c) Forming holes for pipes and the like.
(d) Cranks and upstands.
(e) Bedding and pointing eaves filler-pieces, verges and the like.
(f) Narrow width and small quantities.
(g) Use of recommended fasteners, washers and any items used to prevent electrolysis
corrosion.
(h) Fixing with screws, nails, straps, bracket, etc. in accordance with the
manufacturers instructions.
(i) Cement grout and cement slurry, adhesive, removing paper backing, cleaning and
pointing (including material) joints to match colour of the tiles.
(j) Mastic pointing, dividing strips, etc and testing against leaks.
(k) Bedding and pointing of valley tiles, ridges-tiles, hip tiles and vertical angle-tiles
with cement mortar.

SOR for Building Works 2014

(l)
(m)
(n)
(o)

Bending edges up or down at ridge and gutter, etc.


Notching and bending edges of hips and ridge capping and the like to match
roofing profile.
Painting all screw caps, bolts, nail head, washer, straps, bracket etc with
matching anti-corrosive paint.
Providing warranty or guarantee as specified.

Rates for prefabricated membrane and built-up roofing systems shall include:
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)

Laps and joints, including bonding adhesives, reinforcement mats and strips etc.
Narrow widths.
Protection.
Surface treatment and preparation.
Provide warranty or guarantee as specified.
Forming arises, fair edges, butt joints, etc.
Fitting and sealing around inlets, outlets, projections and the like.
Test on joint and water ponding test.

Rates for flashing, gutter, capping and the like shall include:
(a)
(b)
(c)

Laps, passings in the running lengths, turning up and down of edges, fixing and
pointing.
Forming all angles, ends, outlets and any other sundry items of a like nature.
Brackets, straps, hangers and other necessary fixings.

(G) Carpentry And Ironmongery


Rates for all carpentry, timberworks are to include for all labour to notching, halving,
morticing, tenoning and wedging, scarfing, dovetailing, sinking for heads of bolts and
nuts and trimming for openings.
Rates for carpentry timber shall include:
(a)
(b)
(c)
(d)
(e)

Short length and small quantities.


Cutting, notching, boring, sinking, pelleting, mitering, halving, morticing,
tenoning, dove-tailing and scarfing.
Temporary supports.
Fixing with screws, nails, fastening devices, pin, puttying, glue, etc
Sundries items of a like nature.

Rates for dry lining and partition shall include:


(a)
(b)
(c)
(d)
(e)
(f)
(g)

Short length, narrow widths, small quantities and irregular shaped.


Cutting and boring holes for pipes, services fittings etc and make good.
Protection and cleaning on completion.
All fastening devices.
Setting out panels to form equal margins on all sides.
Frame.
Submission of shop drawings.

Rates for insulating board, woodwool board and other building boards shall include:
(a)
(b)
(c)

Narrow width and small quantities.


Cutting and boring holes for pipes, etc.
Protection and cleaning on completion.

SOR for Building Works 2014

Rates for building board and ceiling boarding shall include:


(a)
(b)
(c)

All fastening devices.


Narrow width and small quantities.
Cutting openings for services fittings and making good.

Rates for fire rated doors shall include:


(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)

Door leaf
Intumescent strips let into grooves around the door.
BOMBA certification.
Glazing and vision panel.
Door frame, beading, architrave and packing piece.
Filling voids between framing and brickwall or concrete walls with approved
materials as deemed necessary by the Architect/Engineer.
Apply one coat of aluminium wood primer to back of door frame before fixing.
Apply two coats of approved wood preservative to packing piece.
Heel stone, dowel and holdfast

Rates for non-fire rated doors shall include:


(a)
(b)

Door leaf
Glazing, vision panel, side and overhead glazed and louvred panel.

Rates for door frame to non-fire rated doors shall include:


(a)
(b)
(c)
(d)
(e)

Door frame, framing to all side and overhead glazed and louvre panels, beading,
architrave and packing piece.
Filling voids between framing and brickwall or concrete walls with approved
materials as deemed necessary by the Architect/Engineer.
Apply one coat of aluminium wood primer to back of door frame before fixing.
Apply two coats of approved wood preservative to packing piece.
Heel stone, dowel and holdfast.

Rates for glazed doors and windows shall include glazing beads loosely pinned to
glazed openings for subsequent fixing.
Rates for ironmongery shall include:
(a)
(b)
(c)
(d)
(e)

Matching screw.
Cutting, sinking, boring and morticing.
Oiling, easing and adjusting all movable parts.
Taking out and refixing after painting as directed.
Marking, labeling and handing over keys.

SOR for Building Works 2014

(H) Plastering, Paving And Tiling


Rates for each item of paving shall be held to include for all rounded angles, arrises and
making good and any other sundry items of alike nature.
Rates for each item of skirtings, risers, channels and the like shall be held to include for
all short lengths formed, cut and purpose made angles, junctions, ends, etc. and making
good and any other sundry items of alike nature.
Rates for plastering, rendering etc. shall include for raking out joints of brickwork,
blockwork and masonry or hacking concrete as key.
Overall rates for each item of plastering etc. shall be held to include for narrow widths
and small quantities, temporary rules, joints between different types of plastering,
internal angels, arrises, quirks, rounded coves and external angles not exceeding 1
radius and mitres, stops etc. on cornices, mouldings, enrichments, covers, skirtings,
gutters and strings and making good any other sundry items of alike nature.
Rates for plastering shall include:
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)

Narrow widths and small quantities.


Temporary rules and templates.
Cleaning, keying and slurrying to base.
Jointing between different types of finishes and between old and new finishes.
Groin points and other intersections of curved surfaces.
All other sundry items of a like nature.
Exmet or other approved wire mesh as key for plaster at junction between
concrete and brickwork/timber and the like.
Mock-up sample.

Rates for wall tiling shall include:


(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(j)
(k)
(l)
(m)
(n)

All round edges and arrises.


Narrow widths and small quantities.
Temporary rules and templates.
Backing screed.
Soaking tiles in waters before laying.
Cleaning, keying and slurrying to base.
Notching, raking and curved cutting.
Jointing between different types of finishes and between old and new finishes.
Groin points and other intersections of curved surfaces.
Joint filler and joint grout/sealant.
Laying to selected pattern.
Mock-up sample.
Proprietary fixing adhesives.
All other sundry items of a like nature.

Rates for slab and block finishes to walls shall include:


(a)
(b)
(c)
(d)
(e)
(f)

Cutting and drilling of fixing slits and holes


Chamfers, splays, rebates, grooves, etc. including polished exposed edges.
Notching, raking and curved cutting.
Rules, spacer or distance blocks.
Hooks, brackets, straps and other fixing accessories.
Proprietary fixing adhesive.

SOR for Building Works 2014

(g)
(h)
(i)
(j)

Joint filler and joint grout/sealants.


Cleaning.
Mock-up sample and dry laying.
All other sundry items of a like nature.

Rates for floor tiling and paving shall include:


(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(j)
(k)
(l)
(m)
(n)
(o)

All round edges, internal and external angles, and arrises.


Narrow widths and small quantities.
Temporary rules and templates.
Cleaning, keying and slurrying to base.
Notching, throating, forming holes, and splay, raking and curved cutting.
Jointing between different types of finishes and between old and new finishes.
Groin points and other intersections of curved surfaces.
Screeding.
Anchorages, fixing accessories on, for securing to floor or wall.
Laying flat or to slopes and falls.
Joint filler and joint grout/sealant.
Proprietary fixing adhesives.
Mock-up sample and laying to selected pattern.
Cleaning, protecting and polishing on completion and before handing over.
All other sundry items of a like nature.

(I) Structural Steel Work And Metal Work


Rates for structural steelwork and metal work shall include:
(a)
Weight of welded metal and rolling margin.
(b)
All straight, raking, bevel and play cutting and notching.
(c)
All shop and site welding, drilling, holes and openings (no deduction in weight
shall be made for same) including those required for other trades.
(d)
Marking, hoisting and erecting temporary braces and support.
(e)
Filing smooth welds exposed to weld.
(f)
All fixing accessories and grouting.
(g)
Preparing and priming with approved painting system.
(h)
Preparation and submission of shop drawings.
(i)
Testing.
Rates for metal suspended ceiling frame work shall include:
(a)
All suspended accessories.
(b)
Edge trims.
(c)
Trimmer bars for lighting air-conditioning grilles, speakers, etc.
(d)
Preparation and submission of shop drawings.
Rates for aluminium framed doors and windows shall include:
(a)
(b)
(c)
(d)
(e)
(f)

Labour and material for the completion installation of the framed doors and
windows.
Neoprene friction seal, compression seal, hardwares, fixing accessories, cement
filleting around frame and sealant pointing.
Structural stiffener and lintel.
Holdfast and ironmongery.
Protection and cleaning.
Preparation and submission of shop drawings.

SOR for Building Works 2014

g)

Sample, mock-up unit and testing.

Rates for mild steel tubing are to include for short running lengths, sockets, backnuts,
elbows and bends.
(J) Plumbing
Rates for pipework shall include:
(a)
(b)
(c)
(d)
(e)
(f)
(g)

Short lengths.
Running joints and sockets.
Made bends.
Bends, tees, reducers, end caps and the like fittings.
Fixing brackets and clips.
Forming perforations, holes, etc in walls and slabs and providing sleeves.
Chasing in walls and slabs.

Rates for sanitary fittings shall include:


(a)
(b)
(c)
(d)

All fixings and jointing to services.


Brackets and all other necessary accessories for the complete functioning of
the fitting.
Submit sample.
Protecting and cleaning on completion.

(K) Glazing
Rates for glazing shall include:
(a)
(b)
(c)
(d)
(e)
(f)
(g)

Setting blocks, distance pieces and like accessories for fixing.


Drilling fixing holes and the like in glass.
Cleaning off protective wax or tape in glazing rebates.
Gasket and glazing compounds.
Polishing and grinding of edges.
Additional costs involved in using sheets which are larger than the
manufacturers standard stock size.
Cleaning.

(L) Painting
Rates for painting shall include:
(a)
(b)
(c)
(d)
(e)
(f)
(g)

Preparatory work such as cleaning, rubbing down, knotting, filling, stopping and
the like.
Rubbing down between coats.
Cutting all edges to line.
Painting all tracks, wall hooks, holderbats, brackets, ears and the like for
pipework and gutters.
The use of different colours to walls, ceilings, doors, frames and the like in
accordance with the Architects colour scheme.
Scaffolding and staging.
Provide warranty / guarantee as specified.

SOR for Building Works 2014

(M) Drainage
Rates for surface water drainage and culvert shall include:
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)

Setting out.
All short lengths.
Jointing and bedding and making smooth running joints.
Cutting culvert pipes for chamfers, ends, junction and for jointing.
Additional beds and surrounds at junctions, beds, ends, etc.
Laying to falls.
Cement rendering.
Forming angles, ends, outlets, junctions, connecting to sumps, drains, etc.

Rates for pipework for soil drainage shall include:


(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
(j)

Running joints, short lengths, support, saddles, sling, fixing bolts and
foundation bolts.
Site and laboratory test on material and provide test certificates.
Temporary stoppers or plugs.
Purpose made brackets and hangers.
Provide and building in all sleeves.
Cleaning out interior of pipes.
Preparing ends of pipes for pipe joints and jointing.
Cutting pipe for chamfers, bends, junctions and for jointing, etc.
Mechanical and flexible coupling.
External protection to flanged joints and flexible couplings.

Rates for pipework and fire hydrants for water reticulations system shall include:
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)

Running joints, deflecting joints, short lengths, support, saddles, sling, fixing
bolts and foundation bolts.
Site and laboratory test on material and provide test certificates.
Cleaning out interior of pipes.
Preparing ends of pipes for pipe joints and jointing.
Cutting pipe for chamfers, bends, junctions and for jointing, etc.
Mechanical and flexible coupling.
External protection to flanged joints and flexible couplings.
Painting all uncoated surfaces of pipework, valves and fittings.
Flushing, testing and commissioning of pipelines.

Rates for valves, hydrants and the like specials are to include for all components pipes
necessary for the complete installation including all fixing accessories and extra joints to
pipes.
(N) Bituminous Road And Hardstandings
Rates for site surface water drainage and culvert shall include:
(a)
(b)
(c)
(d)
(e)
(f)

Sampling and testing of aggregates and bituminous mixtures as specified.


Protecting mixed material in transit and while awaiting tripping.
Laying, rolling and consolidating sub-base, base course, binder and wearing
course in layers or sequence as required.
Laying by hand of narrow strips remaining alongside machine work.
Making joints, working around manhole covers and other like projections.
Finishing surfaces to gradient and falls.

SOR for Building Works 2014

10

g)
h)

Added filler to bituminous mixture.


Maintenance of surface as work progress.

(O) Gabion Work


Rates for gabion work shall include:
(a)
(b)
(c)
(d)
(e)
(f)

Excavation and disposal of excavated material off site to Contractors own


dump.
Dewatering, upholding the sides of excavation and keeping the excavation free
of water.
Trimming and leveling at founding / base level.
Cage and tying wire.
Filling material.
Transport, handling, assembling, tying, fixing, staking, tensioning and placing
in dry condition and / or under water.

(P) Turfing And Tree Planting


Rates for seeding and turfing shall include:
(a)
(b)
(c)
(d)

Carry out the work in such sequence or section as directed.


Preparatory work in forking and loosening ground surface including riding all
weed, roots and debris.
Dressing with fertilizer, tending, watering, covering with wet sacking, moving
and protection of newly seeded / turfed area.
Maintenance.

Rates for tree planting shall include:


(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)

Carry out the work in such sequence or section as directed.


Selection and tagging of plant material.
Planting operation including excavation for rootball, top soil, refilling, support
and ties.
Irrigation, pruning and trimming.
Plant replacement.
Spraying or other disease control operation.
Protection.
Maintenance.

SOR for Building Works 2014

11

PILING
Item

Description

Unit

Rate (RM)

No.
Precast Concrete Piles
1

Supply, handle & pitch 150mm x 150mm initial/head pile 6.00m long.

38.30

Supply, handle & pitch 150mm x 150mm extension pile 6.00m long.

35.10

Supply, handle & pitch 200mm x 200mm initial/head pile 6.00m long.

70.50

Supply, handle & pitch 200mm x 200mm extension pile 6.00m long.

66.00

Supply, handle & pitch 250mm x 250mm initial/head pile 6.00m long.

110.40

Supply, handle & pitch 250mm x 250mm initial/ head pile 9.00m long.

98.60

Supply, handle & pitch 250mm x 250mm initial/ head pile 12.00m long.

93.80

Supply, handle & pitch 250mm x 250mm extension pile 6.00m long.

104.60

Supply, handle & pitch 250mm x 250mm extension pile 9.00m long.

99.30

10

Supply, handle & pitch 250mm x 250mm extension pile 12.00m long.

90.90

11

Supply, handle and pitch 300mm x 300mm initial/head pile 6.00m long.

174.00

12

Ditto 9.00m long.

153.10

13

Ditto 12.00m long.

143.20

14

Supply, handle and pitch 300mm x 300mm extension pile 6.00m long.

166.10

15

Ditto 9.00m long.

148.60

16

Ditto 12.00m long.

139.90

17

Supply, handle and pitch 350mm x 350mm initial/head pile 6.00m long.

228.40

18

Ditto 9.00m long.

200.90

19

Ditto 12.00m long.

187.10

20

Supply, handle and pitch 350mm x 350mm extension pile 6.00m long.

218.30

21

Ditto 9.00m long.

194.10

22

Ditto 12.00m long.

182.10

23

Supply, handle and pitch 400mm x 400mm initial/head pile 6.00m long.

298.90

24

Ditto 9.00m long.

263.00

25

Ditto 12.00m long.

244.90

26

Supply, handle and pitch 400mm x 400mm extension pile 6.00m long.

286.50

SOR BUILDING 2014/Page 1 of 40

'

PILING (Cont d)
Item

Description

No.

Unit

Rate (RM)

'

Precast Concrete Piles (Cont d)


27

Ditto 9.00m long.

254.70

28

Ditto 12.00m long.

238.90

29

Drive to set 200mm x 200mm pile.

8.40

30

Ditto 250mm x 250mm pile.

10.80

31

Ditto 300mm x 300mm pile.

13.20

32

Ditto 350mm x 350mm pile.

17.90

33

Ditto 400mm x 400mm pile.

23.80

34

Drive to set 200mm x 200mm pile as raker piles.

17.90

35

Ditto 250mm x 250mm pile.

21.70

36

Ditto 300mm x 300mm pile.

25.50

37

Ditto 350mm x 350mm pile.

30.90

38

Ditto 400mm x 400mm pile.

33.90

39

Butt weld connection 0.60m girth between edges of and including mild steel
extension head, base cap plates, bars etc and including coated heavily with
bituminous compound for jointing 200mm x 200mm R.C piles.

NO

106.80

40

Ditto for jointing 250mm x 250mm R.C piles.

NO

160.20

41

Ditto for jointing 300mm x 300mm R.C piles.

NO

231.40

42

Ditto for jointing 350mm x 350mm R.C piles.

NO

314.40

43

Ditto for jointing 400mm x 400mm R.C piles.

NO

415.20

44

Cut off and dump away surplus length of 150mm x 150mm precast concrete pile
and strip off pile head, bend back reinforcement for connection as specified.

NO

16.60

45

Ditto 200mm x 200mm ditto.

NO

23.80

46

Ditto 250mm x 250mm ditto.

NO

29.70

47

Ditto 300mm x 300mm ditto.

NO

35.60

48

Ditto 350mm x 350mm ditto.

NO

41.60

49

Ditto 400mm x 400mm ditto.

NO

47.50

50

Provide all equipment, hydraulic jack, deflection gauges, kentledge, temporary


staging, etc. and test a test pile of any size to a vertical load test including all
extra cost before commencement of the main piling works complete with report.

Tonne

142.40

SOR BUILDING 2014/Page 2 of 40

'

PILING (Cont d)
Item

Description

No.

Unit

Rate (RM)

Precast Concrete Spun Piles


51

Supply, handle & pitch 250mm diameter initial/ head pile 6.00m long (Class B).

89.90

52

Ditto 9.00m long.

77.70

53

Ditto 12.00m long.

72.20

54

Supply, handle & pitch 250mm diameter extension pile 6.00m long (Class B).

81.90

55

Ditto 9.00m long.

72.40

56

Ditto 12.00m long.

68.20

57

Supply, handle & pitch 300mm diameter initial/head pile 6.00m long (Class B).

115.30

58

Ditto 9.00m long.

101.20

59

Ditto 12.00m long.

93.80

60

Supply, handle & pitch 300mm diameter extension pile 6.00m long (Class B).

105.50

61

Ditto 9.00m long.

94.30

62

Ditto 12.00m long.

88.80

63

Supply, handle & pitch 350mm diameter initial/head pile 6.00m long (Class B).

150.30

64

Ditto 9.00m long.

131.10

65

Ditto 12.00m long.

121.00

66

Supply, handle & pitch 350mm diameter extension pile 6.00m long (Class B).

137.80

67

Ditto 9.00m long.

122.80

68

Ditto 12.00m long.

114.60

69

Supply, handle & pitch 400mm diameter initial/head pile 6.00m long (Class B).

189.80

70

Ditto 9.00m long.

168.10

71

Ditto 12.00m long.

156.10

72

Supply, handle & pitch 400mm diameter extension pile 6.00m long (Class B).

177.40

73

Ditto 9.00m long.

158.30

74

Ditto 12.00m long.

148.80

75

Supply, handle & pitch 450mm diameter initial/head pile 6.00m long (Class B).

212.20

76

Ditto 9.00m long.

185.90

SOR BUILDING 2014/Page 3 of 40

'

PILING (Cont d)
Item

Description

No.

Unit

Rate (RM)

'

Precast Concrete Spun Piles (Cont d)


77

Ditto 12.00m long.

172.30

78

Supply, handle & pitch 450mm diameter extension pile 6.00m long (Class B).

195.10

79

Ditto 9.00m long.

174.60

80

Ditto 12.00m long.

163.80

81

Supply, handle & pitch 600mm diameter initial/head pile 6.00m long (Class B).

359.50

82

Ditto 9.00m long.

316.10

83

Ditto 12.00m long.

296.50

84

Supply, handle & pitch 600mm diameter extension pile 6.00m long (Class B).

335.60

85

Ditto 9.00m long.

300.20

86

Ditto 12.00m long.

283.80

87

Drive 250mm diameter pile.

19.00

88

Ditto 300mm ditto.

21.50

89

Ditto 350mm ditto.

35.70

90

Ditto 400mm ditto.

41.60

91

Ditto 450mm ditto.

53.50

92

Ditto 600mm ditto.

59.40

93

Drive 250mm diameter pile as raker pile.

24.70

94

Ditto 300mm ditto.

27.80

95

Ditto 350mm ditto.

46.40

96

Ditto 400mm ditto.

54.10

97

Ditto 450mm ditto.

69.40

98

Ditto 600mm ditto.

77.20

99

Butt weld connection 0.8m girth between edges of mild steel extension head and
base cap plates including coated heavily with bituminuos compound (for 250mm
diameter Spun piles).

NO

118.70

100

Ditto 300mm diameter Spun piles.

NO

142.40

101

Ditto 350mm diameter Spun piles.

NO

178.00

SOR BUILDING 2014/Page 4 of 40

'

PILING (Cont d)
Item

Description

No.

Unit

Rate (RM)

'

Precast Concrete Spun Piles (Cont d)


102

Ditto 400mm diameter Spun piles.

NO

213.60

103

Ditto 450mm diameter Spun piles.

NO

261.00

104

Ditto 600mm diameter Spun piles.

NO

332.10

105

Cut off 250mm diameter precast concrete spun pile to the required level and
roughen the inner surface to detail.

NO

35.70

106

Ditto 300mm diameter ditto.

NO

41.60

107

Ditto 350mm diameter ditto.

NO

47.50

108

Ditto 400mm diameter ditto.

NO

53.50

109

Ditto 450mm diameter ditto.

NO

59.30

110

Ditto 600mm diameter ditto.

NO

89.00

111

Supply and install 12mm diameter high yield steel reinforcement in pile head to
detail.

KG

4.80

112

Ditto 16mm diameter ditto.

KG

4.70

113

Provide and weld 6mm thick mild steel plates to detail for 250mm diameter piles.

NO

45.10

114

Ditto 300mm diameter piles.

NO

53.50

115

Ditto 350mm diameter piles.

NO

68.90

116

Ditto 400mm diameter piles.

NO

80.70

117

Ditto 450mm diameter piles.

NO

101.20

118

Ditto 600mm diameter piles.

NO

148.40

119

Supply, place and compact grade 30/20 concrete in pile hollow section as
specified.

3
M

355.90

120

Provide all equipment, hydraulic jack, deflection gauges, kentledge, temporary


staging, etc. and test a test pile of any size to a vertical load test including all
extra cost before commencement of the main piling works.

SOR BUILDING 2014/Page 5 of 40

Tonne

142.40

EXCAVATOR
Item
No.

Description

Unit

Rate (RM)

Clearing and grubbing within the Site of all trees, bushes, etc.

Ha

3,113.50

Cut down and clear away from site, trees exceeding 300mm and not exceeding
600mm girth measured at 1.00m above ground level including grubbing up roots
and filling up holes with approved earth.

NO

112.10

Cut down and clear away from site, trees exceeding exceeding 600mm and not
exceeding 1200mm girth measured at 1.00m above ground level including
grubbing up roots and filling up holes with approved earth.

NO

186.90

Cut down and clear away from site, trees exceeding 1200mm and not exceeding
1800mm girth measured at 1.00m above ground level including grubbing up roots
and filling up holes with approved earth.

NO

298.90

Excavate oversite average 150mm deep to level off formation or reduce level and
dump away excess earth.

Excavate to obtain formation level, load and transport excavated material to


temporary spoil heap or filling area within site (by mechanical equipment).

Excavate to obtain formation level, load and transport excavated material to


temporary spoil heap or filling area within site (by mechanical equipment), but
transport away from site within 1 km lead.

Excavate to obtain formation level, load and transport excavated material to


temporary spoil heap or filling area within site (by mechanical equipment),
transport only through each subsequent 1 km lead.

Excavate for foundation, trenches, pier holes, manholes, septic tanks, filter
beds etc. not exceeding 1.50m deep, part backfill and remove surplus spoil
and deposit, spread and level on site as specified (manually).

Excavate for foundation, trenches, pier holes, manholes, septic tanks, filter
beds etc. exceeding 1.50m deep and not exceeding 3.00m deep, part backfill
and remove surplus spoil and deposit, spread and level on site as specified
(manually).

Excavate for foundation, trenches, pier holes, manholes, septic tanks, filter
beds etc. exceeding 3.00m deep and not exceeding 4.50m deep, part backfill
and remove surplus spoil and deposit, spread and level on site as specified
(manually).

Excavate for foundation, trenches, pier holes, manholes, septic tanks, filter
beds etc. to irrespective of depth (by mechanical equipment).

10

11

12

13

14

2.00

8.90

9.50

1.00

19.90

22.40

31.20

12.50

25.00

49.90

18.80

Extra over for excavation in rock including remove from site:


(a) Open excavation (including use of explosive, etc).

(b) Trench excavation (including for foundation, trenches, pier holes, manholes,
septic tanks, filter beds and etc.).

'

Excavation and cart away of unsuitable material to contractor s own dumping


source within 15km from site (by mechanical equipment).

SOR BUILDING 2014/Page 6 of 40

EXCAVATOR(CONT D)
'

B
Item
No.
15

Description

Unit

Rate (RM)

'

Imported approved earth from contractor s own source within 15 km from site
including unloading in filling areas.

28.80

2.50

6.40

74.80

16

Spread, level and compact excavated earth for filling in layers as specified in filling
areas.

17

Spread, level and compact surplus excavated earth in areas away from site, within
3 km lead.

18

Supply, lay and compact hardcore of approved aggregates.

19

50mm Thick blinding on top of hardcore.

SOR BUILDING 2014/Page 7 of 40

3.10

CONCRETOR
Item
No.

Description

Unit

Lean concrete (Grade 15) in 50mm thick blinding.

Mass Concrete (Grade 20) in non structural works such as pavements,


upstands, kerbs and the like.

Reinforced concrete (Grade 25) in sub-structural works such as pile caps, pad
footings, column stumps, and the like.

Reinforced concrete (Grade 30) in sub-structural works such as pile caps, pad
footings, column stumps, and the like.

Reinforced concrete (Grade 40) in sub-structural works such as pile caps, pad
footings, column stumps, and the like.

Reinforced concrete (Grade 25) in sub-structural works such as ground beams,


ground slab, apron slabs, steps, platform slabs, ramp and the like.

Reinforced concrete (Grade 30) in sub-structural works such as ground beams,


ground slab, apron slabs, steps, platform slabs, ramp and the like.

Reinforced concrete (Grade 40) in sub-structural works such as ground beams,


ground slab, apron slabs, steps, platform slabs, ramp and the like.

Reinforced concrete (Grade 25) in super-structural works such as columns,


stiffeners, walls, and the like.

Reinforced concrete (Grade 30) in super-structural works such as columns,


stiffeners, walls, and the like.

Reinforced concrete (Grade 40) in super-structural works such as columns,


stiffeners, walls, and the like.

Reinforced concrete (Grade 25) in super-structural works such as suspended


floor beams, suspended floor slabs, roof beams, roof slabs, gutter, canopy slabs,
staircases, landing slab, and the like.

Reinforced concrete (Grade 30) in super-structural works such as suspended


floor beams, suspended floor slabs, roof beams, roof slabs, gutter, canopy slabs,
staircases, landing slab, and the like.

Reinforced concrete (Grade 40) in super-structural works such as suspended


floor beams, suspended floor slabs, roof beams, roof slabs, gutter, canopy slabs,
staircases, landing slab, and the like.

Mass Concrete (Grade 20) in civil works such as fencing post footings, thrust
blocks, scour stops, road kerb bedding, and the like.

Reinforced concrete (Grade 25) in road pavement slabs, cross-over slabs, and
the like.

Reinforced concrete (Grade 25) in sewerage works such as septic tanks,


manholes, and the like.

10

11

12

13

14

15

16

17

SOR BUILDING 2014/Page 8 of 40

Rate (RM)

15.60

324.00
348.67
373.70
423.60
361.20
386.10
436.00
361.20
386.10
436.00

367.50

392.40

442.20
323.90

348.70

373.70

'

CONCRETOR... (CONT D)
Item
No.
18

19

20

21

22

23

24

25

26

27

28

Description

Unit

Rate (RM)

Mild steel bars in reinforcement to concrete work generally including all cutting,
bending and placing in position:
a)

6 mm Diameter.

KG

3.70

b)

10mm Diameter.

KG

3.70

c)

12mm Diameter.

KG

3.70

d)

16mm - 32mm Diameter.

KG

3.50

e)

above 32mm Diameter.

KG

3.50

High tensile steel bars in reinforcement to concrete work, generally including all
cutting, bending and placing in position:
a)

10mm Diameter.

KG

3.70

b)

12mm Diameter.

KG

3.70

c)

16mm - 32mm Diameter.

KG

3.50

Welded steel fabric reinforcement of 100mm x 200mm weighing 3.73 kg/m and
embedded in concrete (MS-B283/ B6).

Welded steel fabric reinforcement of 100mm x 200mm mesh weighing 4.53


2
kg/m ditto(MS-B385/B7).

Welded steel fabric reinforcement of 100mm x 200mm mesh weighing 5.93


2
kg/m ditto (MS-B503/B8).

Welded steel fabric reinforcement of 100mm x 200mm mesh weighing 6.97


2
kg/m ditto (MS-B636/B9).

Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 2.22


2
kg/m ditto(MS-A142/A6).

Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 3.02


2
kg/m ditto(MS-A1 93/A7).

Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 3.95


2
kg/m ditto (MS - A252/A8).

Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 4.99


2
kg/m ditto (MS-A318/A9).

Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 6.16


2
kg/m ditto(MS-A393/A1 0).

24.80
30.20
39.50
46.40
14.90
20.30
26.70
33.30
41.60

29

Expanded metal reinforcement of 100mm x 400mm weighing 2.61kg/m (MSC283/ C6).

30

Expanded metal reinforcement of weighing 4.34 kg/m (MS-C503/ C8).

SOR BUILDING 2014/Page 9 of 40

17.40

28.83

M
M

'

CONCRETOR... (CONT D)
Item
No.
31

Description

Unit

Rate (RM)

Mild steel fabric mesh reinforcement :


2

10.50

8.90

6.30

40.00

40.00

41.10

41.10

43.60

3.10

6.40

a)

BRC 65.

b)

BRC 66.

c)

BRC 610.

Sawn Formwork As Specified


32

To sides of foundation and ground beam.

33

To sides of wall.

34

To sides of column, staircase, lintols etc.

35

To sides and soffit of beam.

36

To soffit of suspended floor slab, roof slab, landing slab etc.

37

Extra over last four items for sloping surfaces.

38

Extra over formwork for curved on plan and elevation to varying radius.

39

Extra over for strutting to soffits of slab/ beams exceeding 3.60m high for every
600mm stages.

40

Extra over sawn formwork for wrot surfaces.

41

Extra over sawn formwork for patterned formwork with fillets at 150mm centres
or in 150mm wide "V" jointed timber boards.

18.80

12mm Bitumen impregnated fibreboard 150mm wide as expansion joint filler in


reinforced concrete structure including filling 10mm x 10mm recess with non
shrinkable mastic grouting.

35.00

27.50

41.10

44.90

42

5.00
7.50

Precast Concrete Work


43

44

45

150 mm Wide internal precast reinforced concrete (Grade 25) half round surface
water drain channel including bends, junctions etc. finished fair on exposed
surfaces and bedding as specified, including all necessary excavations and part
backfill.
225 mm Wide internal precast reinforced concrete (Grade 25) half round surface
water drain channel including bends, junctions etc. finished fair on exposed
surfaces and bedding as specified, including all necessary excavations and part
backfill.
300 mm Wide internal precast reinforced concrete (Grade 25) half round surface
water drain channel including bends, junctions etc. finished fair on exposed
surfaces and bedding as specified, including all necessary excavations and part
backfill.

SOR BUILDING 2014/Page 10 of 40

'

CONCRETOR... (CONT D)
Item
No.
46

47

Unit

Rate (RM)

375 mm Wide internal precast reinforced concrete (Grade 25) half round surface
water drain channel including bends, junctions etc. finished fair on exposed
surfaces and bedding as specified, including all necessary excavations and part
backfill.

56.20

450mm x 450mm x 75mm Thick precast reinforced concrete (Grade 25)


'
'
longkang pencegah malaria finished fair on exposed surfaces and bedding as
specified including all necessary excavation.

139.60

Description

48

50mm Thick precast reinforced concrete (Grade 25) drain cover with and
2
including one layer of fabric reinforcement, weighing 2.35kg/m (A6).

49

112mm x 150mm Precast concrete (Grade 25) lintol including formwork but
excluding reinforcement.

43.60

21.20

DAMP PROOF MEMBRANE


50

51

'

Pabkote No.3 or other approved bituminous damp proof membrane applied on


concrete surfaces all to the approval of the S.O and in accordance with the
'
manufacturer s instruction.

6.40

Bitumen based expansion joints for concrete pavement.

12.50

SOR BUILDING 2014/Page 11 of 40

BRICKLAYER
Item
No.

Description

Unit

79.80

89.80

One brickwall in common bricks in cement mortar (1:6) as specified.

Ditto in cement mortar (1:3) as specified.

Half brickwall in common bricks in cement mortar (1:6) reinforced with and
including brick reinforcement at every fourth course.

Ditto in cement mortar (1:3) reinforced with and including brick reinforcement at
every fourth course.

Extra over common brickwork for fair face in cement mortar (1:6) pointing on one
side only as specified.

Half brickwall built honey-comb in cement mortar (1:6) with 113mm spaces as
specified.

Half brickwall built entirely of facing bricks in gauged mortar (1:1:6) stuck
weather pointing as specified.

One brickwall in cement bricks in cement mortar (1:6) as specified.

One brickwall in cement bricks in cement mortar (1:3) as specified.

10

Half brickwall in cement bricks in cement mortar (1:6) reinforced with and
including brick reinforcement at every fourth course.

11

Half brickwall in cement bricks in cement mortar (1:3) reinforced with and
including brick reinforcement at every fourth course.

12

One brickwall in calcium silicate bricks in cement mortar (1:6) as specified.

13

One brickwall in calcium silicate bricks in cement mortar (1:3) as specified.

14

Half brickwall in calcium silicate bricks in cement mortar (1:6) reinforced with and
including brick reinforcement at every fourth course.

15

42.40
44.90

9.90
31.20

89.80

81.10

84.80

42.40
44.90

84.80

87.30

Half brickwall in calcium silicate bricks in cement mortar (1:3) reinforced with
and including brick reinforcement at every fourth course.

16

Damp proof courses as specified (measured nett with no allowance made for
laps in various widths as specified).

17

90mm Thick precast cement and sand hollow blocks in cement mortar (1:6) as
specified.

18

90mm Thick precast cement and sand hollow blocks in cement mortar (1:3) as
specified.

19

114mm Thick precast cement and sand hollow blocks in cement mortar (1:6) as
specified.

SOR BUILDING 2014/Page 12 of 40

Rate (RM)

43.60

44.90
22.40
33.70
41.10

37.50

'

BRICKLAYER... (CONT D)
Item
No.
20

21

Description

Unit

114mm Thick precast cement and sand hollow blocks in cement mortar (1:3) as
specified.

190mm Thick precast cement and sand hollow blocks in cement mortar (1:6) as
specified.

49.90

87.30

22

190mm Thick precast cement and sand hollow blocks in cement mortar (1:3) as
specified.

23

450mm Thick limestone rubble walling in cement mortar (1:3) as specified.

24

450mm Thick granite rubble walling in cement mortar (1:3) as specified.

25

Extra over uncourse random stone walling for fair face in cement mortar (1:3)
and pointing as specified.

26

Extra over for squared rubble fair face and pointed as specified.

SOR BUILDING 2014/Page 13 of 40

Rate (RM)

99.70

218.10

243.00

35.00
62.30

DRAINLAYER
Item
No.

Description

Unit

Rate (RM)

Excavate trench for 100mm diameter drains and bed 400mm wide not exceeding
1.50m deep and average 900mm deep and back filling trench including
removing surplus soil and deposit and spread and level on site as specified.

7.50

Excavate trench for 100mm diameter drains and bed 400mm wide exceeding
1.50m deep but not exceeding 3.00m deep and average 1.80m deep and back
filling trench including removing surplus soil and deposit and spread and level on
site as specified.

15.00

Excavate trench for 150mm diameter drains and bed 450mm wide not exceeding
1.50m deep and average 900mm deep and back filling trench including
removing surplus soil and deposit and spread and level on site as specified.

9.90

Excavate trench for 150mm diameter drains and bed 450mm wide exceeding
1.50m deep but not exceeding 3.00m deep and average 1.80m deep and back
filling trench including removing surplus soil and deposit and spread and level on
site as specified.

18.80

150mm Concrete (Grade 20) bed 450mm wide under 100m diameter drain pipe
and haunch as specified.

41.10

150mm Concrete (Grade 20) bed 500mm wide under 150mm diameter drain
pipe and haunch as specified.

47.40

150mm Concrete (Grade 20) bed 500mm wide under 100mm diameter drain
pipe and completely surround as specified.

68.60

150mm Concrete (Grade 20) bed 500mm wide under 150mm diameter drain
pipe and completely surround as specified.

87.30

Concrete (Grade 25) in benching average thickness of 150mm to bottom of


manhole finished to steep falls towards channels and rendered with and
including 13mm thick cement and sand (1:3) trowelled smooth.

13mm Thick cement and sand (1:3) waterproofed rendering as specified to


internal sides of manhole or septic tank.

27.50

11

100mm Diameter (medium duty) cast iron drains laid complete as specified.

130.90

12

Extra over for bend.

NO

13

150mm Diameter (medium duty) cast iron drains laid complete as specified.

14

Extra over for bend.

15

100 mm Diameter UPVC Class "C" pipes laid and jointed with solvent weld
complete with bend, sockets, etc as specified and in accordance with
'
manufacturer s instructions.

10

SOR BUILDING 2014/Page 14 of 40

81.10

22.40
180.70

NO

53.70

35.50

DRAINLAYER(CONT D)
'

E
Item
No.

Description

16

Extra over for bend.

17

150 mm Diameter UPVC Class "C" pipes laid and jointed with solvent weld as
'
specified and in accordance with manufacturer s instructions.

Unit

Rate (RM)

NO

25.00

66.10

18

Extra over for bend.

NO

37.50

19

19mm Diameter mild steel rod 750mm girth bent as required and with ends split
caulked and built into brickwork as step iron.

NO

25.00

610mm x 457mm Coated cast iron light duty single seal flat type manhole cover
and frame to BS.497 in grade "C" weighing 25.45kg including setting frame in
cement and sand ( 1:3 ) as specified and sealing cover with grease.

NO

162.00

610mm x 457mm Coated cast iron light duty single seal flat type manhole cover
and frame to BS.497 in grade "C" weighing 38.18kg including setting frame in
cement and sand ( 1:3 ) as specified and sealing cover with grease.

NO

237.70

762mm x 762mm Coated cast iron medium duty single seal flat type manhole
cover and frame to BS.497 in grade "B" weighing 234.00kg including setting
frame in cement and sand ( 1:3 ) as specified and sealing cover with grease.

NO

1,457.10

588mm Diameter coated cast iron heavy duty single seal flat type manhole cover
and frame to BS.497 in grade "A" weighing 245.00kg including setting frame in
cement and sand ( 1:3 ) as specified and sealing cover with grease.

NO

1,525.60

24

30mm - 100mm gauge graded limestone in filter bed as filter media.

106.00

25

100mm Diameter Weidaline HDPE corrugated perforated sub-soil drainage


pipe laid minimum 550mm below ground level in suitable filter material complete
with non-woven geotextile, butt jointed and covered with cut-off halves of the
'
same pipe material, all to the manufacturer s instructions.

25.00

56.20

20

21

22

23

26

"

"

"

"

160mm Diameter Weidaline HDPE corrugated perforated sub-soil drainage


pipe laid minimum 550mm below ground level in suitable filter material complete
with non-woven geotextile, butt jointed and covered with cut-off halves of the
'
same pipe material, all to the manufacturer s instructions.

SOR BUILDING 2014/Page 15 of 40

ROOFER
Item
No.
1

Description

Unit

0.48mm thick Spandek Hi-Ten Colorbond roofing sheet of approved colour fixed
'
in accordance with Manufacturer s Instructions.

0.48mm thick Trimdek Hi-Ten Colorbond roofing sheet of approved colour fixed
'
in accordance with Manufacturer s Instructions.

0.48mm thick Styledek II Colorbond roofing sheet of approved colour fixed in


'
accordance with Manufacturer s Instructions.

Kliplok Hi-Ten Colorbond roofing sheet of approved colour fixed in accordance


'
with Manufacturer s Instructions.
i) 0.48mm thick.
ii) 0.53mm thick.

M
2
M

0.48mm thick Colorbond flashing or ridges of same roofing material as above


(Item 1 to 4).

Rate (RM)

102.10

93.40

84.80

107.10
115.90

79.80

0.48mm thick Styledek II/ ridge/ hip/ half round ridge capping Type S1 & S1A
(2.44m length each).

PIECE

112.10

0.48mm thick Kliplok/ Spandek/ Trimdek Ridge capping Type 1/2/2A (2.44m
length each).

PIECE

112.10

Ditto but for Valley Gutter Type S2 (530mm girth and 2.44m length each).

PIECE

112.10

Ditto but for Valley Gutter Type S3 (470mm girth and 2.44m length each).

PIECE

112.10

10

0.48mm thick Besalon roofing in MultiCote G6 of approved colour fixed in


'
accordance with Manufacturer s Instructions.

0.48mm thick Multi Tile roofing in MultiCote G6 of approved colour fixed in


'
accordance with Manufacturer s Instructions.

0.48mm thick Megatile in MultiCote G6 of approved colour fixed in accordance


'
with Manufacturer s Instructions.

0.48mm thick Millennium tile roofing in MultiCote G6 of approved colour fixed in


'
accordance with Manufacturer s Instructions.

0.48mm thick Multi Klip I roofing in MultiCote G6 of approved colour fixed in


'
accordance with Manufacturer s Instructions.

0.48mm thick Multi Klip II roofing in MultiCote G6 of approved colour fixed in


'
accordance with Manufacturer s Instructions.

0.48mm thick Multi Span roofing in MultiCote G6 of approved colour fixed in


'
accordance with Manufacturer s Instructions.

0.48mm thick Multi Flex roofing in MultiCote G6 of approved colour fixed in


'
accordance with Manufacturer s Instructions.

0.48mm thick Mega Span roofing in MultiCote G6 of approved colour fixed in


'
accordance with Manufacturer s Instructions.

11

12

13

14

15

16

17

18

SOR BUILDING 2014/Page 16 of 40

112.10
99.70
82.20
87.30
112.10
106.00
94.70

88.50

77.00

ROOFER(CONT D)
'

F
Item
No.

Description

19

0.48mm thick Mega Flex roofing in MultiCote G6 of approved colour fixed in


'
accordance with Manufacturer s Instructions.

20

21

22

Unit

Rate (RM)

73.60

0.48mm thick x 2.44m long Ridge cap/ valley gutter/ apron mould/ barge mould
Type 450 of same material as above (Item 10 to 13).
(i) Single tone.
(ii) Double tone.

PIECE
PIECE

117.10
128.40

0.48mm thick x 2.44m long Ridge cap/ valley gutter/ apron mould/ barge mould
Type 300 of same material as above (Item 10 to 13).
(i) Single tone.
(ii) Double tone.

PIECE
PIECE

89.80
99.70

0.48mm thick flashing of same material as above (Item 10 to 13).


(i) Single tone.
(ii) Double tone.

M
2
M

62.30
68.60

23

0.48mm thick x 2.44m long Ridge cap/ valley gutter/ apron mould/ barge mould
Type 450 of same material as above (Item 14 to 17).

PIECE

117.10

24

0.48mm thick x 2.44m long Ridge cap/ valley gutter/ apron mould/ barge mould
Type 300 of same material as above (Item 14 to 17).

PIECE

89.80

25

0.48mm thick flashing of same material as above (Item 14 to 17).

26

77.30

0.48mm thick x 2.44m long Ridge cap/ valley gutter/ apron mould/ barge mould
Type 450 of same material as above (Item 18 to 19).

PIECE

89.80

27

0.48mm thick x 2.44m long Ridge cap/ valley gutter/ apron mould/ barge mould
Type 300 of same material as above (Item 18 to 19).

PIECE

66.10

28

0.48mm thick flashing of same material as above (Item 18 to 19).

SOR BUILDING 2014/Page 17 of 40

47.80

CARPENTER AND JOINER


Item
No.

Description

Unit

Rate (RM)

4,010.20

The Following In Wrot Timber (Timber Species To Follow SG5 Of The


Schedule Of Timber Species Page H/9 Of The Standard Specifications For
Building Works) Unless Otherwise Stated.
"

"

"

"

Frames to doors, windows and vents including fixing (Type SG1 to SG4 ) .

Floor joists, roof trusses, rafters, ceiling joists and partitions including fixing (Type
"
"
"
"
SG1 to SG4 ).

Floor joist, roof trusses, rafters, ceiling joists, partitions and ramps including fixing.

38mm Thick framed, ledged and braced doors and windows including fixing but
excluding ironmongery (measured overall).

38mm Thick panelled doors and casement windows, open and rebated for glass
or other infill (measured separately) including fixing but excluding ironmongery
(measured overall).

51mm Thick louvred doors and windows


ironmongery (measured overall).

38mm Thick skeleton framed flush door covered both sides with 6mm thick
plywood including fixing but excluding ironmongery (measured overall).

Approved one hour fire rated doors in timber frame including assembling all in
'
accordance with the manufacturer s instructions complete with accessories, single
leaf size 900mm x 2100mm x 44mm thick.

NO

996.30

Approved one hour fire rated doors in timber frame including assembling all in
'
accordance with the manufacturer s instructions complete with accessories Double leaf size 1800mm x 2100mm x 44mm thick.

NO

1,992.60

Approved two hour fire rated doors in timber frame including assembling all in
'
accordance with the manufacturer s instructions complete with accessories, single
leaf size 900mm x 2100mm x 48mm thick.

NO

1,681.30

Approved two hour fire rated doors in timber frame including assembling all in
'
accordance with the manufacturer s instructions complete with accessories Double leaf size 1800mm x 2100mm x 48mm thick.

NO

2,988.90

12

28mm Thick approved PVC flush door overall size 750mm x 2100mm including
fixing but excluding ironmongery.

NO

124.60

13

38mm Thick approved PVC flush door overall size 875mm x 2100mm including
fixing but excluding ironmongery.

NO

149.50

14

28mm Thick approved PVC sliding/folding door overall size 775mm x 2125mm
including fixing but excluding ironmongery.

NO

162.00

15

32mm Thick tongued and grooved floor boarding.

16

19mm Thick weather boarding (measured nett).

10

11

including fixing but excluding

SOR BUILDING 2012/Page 18 of 40

3,736.10
3,113.50

205.60

209.30

267.90
99.70

162.00
94.70

CARPENTER AND JOINER(CONT D)


'

G
Item
No.

Unit

Description

Rate (RM)

102.10

89.80

17

25mm Thick barge boards and fascias.

18

19mm Thick boarding in shelves.

19

13mm Thick Damar Minyak wall panelling comprising of 51mm x 13mm and
25mm x 13mm strips fixed at 25mm apart as specified.

20

Moulded skirting, architrave, picture rails and cornices in (Type SG6 ) including
fixing.

21

Staircase component in (Type SG1 to SG4 ) including fixing.

22

13mm Thick soft board in ceiling fixed complete including V-jointed and cutting.

23

3mm Thick asbestos cement sheeting in ceiling fixed complete as specified.

24

5mm Thick asbestos cement sheeting in ceiling fixed complete as specified.

25

6mm Thick asbestos cement sheeting in ceiling fixed complete as specified.

26

9mm Thick chipboard in ceiling fixed complete butt or V-jointed and cutting.

27

13mm Thick chipboard in ceiling fixed complete butt or V-jointed and cutting.

28

9mm Thick gypsum plaster board in ceiling fixed complete including cutting.

29

6mm Thick cemboard in ceiling fixed complete as specified.

30

8mm Thick cemboard in ceiling fixed complete as specified.

31

10mm Thick cemboard in ceiling fixed complete as specified.

32

13mm Thick mineral fibre board ceiling, exposed lay in grid and complete with
aluminium framing complete with suspension wire and other supports.

33

16mm Thick mineral fibre board ceiling, exposed lay in grid and complete with
aluminium framing complete with suspension wire and other supports.

34

13mm Thick mineral fibre board ceiling with concealed metal suspension and joint
edge.

35

16mm Thick mineral fibre board ceiling with concealed metal suspension and joint
edge.

36

9mm Thick plain fibrous plastered ceiling board on and including galvanised iron
suspension system.

37

12mm Thick plain fibrous plastered ceiling board on and including galvanised iron
suspension system.

68.40

38

65mm x 65mm fibrous plastered plain cornice.

22.40

39

"

"

"

"

"

"

"

"

13mm thick Softboard in ceiling fixed complete including V-jointing and cutting.

SOR BUILDING 2014/Page 19 of 40

124.60
4,981.50

5,106.10

47.40

23.20

27.50

32.40

26.90

33.00

31.20

35.00

36.20

38.90

74.80

87.30

99.70

112.10

56.20

31.20

CARPENTER AND JOINER(CONT D)


'

G
Item
No.

Description
"

"

Unit
2

40

3mm thick UAC cement sheeting fixed.

41

4.2mm thick UAC cement sheeting fixed.

42

50mm x 13mm Thick timber strip ceiling fixed with 13mm gap in between.

43

6mm Thick plywood panel (one side) in partition including fixing but excluding
framing.

44

10mm Thick plywood panel (one side) in partition including fixing but excluding
framing.

45

13mm Thick plywood panel (one side) in partition including fixing but excluding
framing.

46

6mm Thick approved cement board (one side) in partition including fixing but
excluding framing.

47

12mm Thick approved cement board (one side) in partition including fixing but
excluding framing.

48

24mm Thick approved cement board (one side) in partition including fixing but
excluding framing.

49

9mm Thick approved gypsum board (one side) in partition including fixing but
excluding framing.

50

12mm Thick approved gypsum board (one side) in partition including fixing but
excluding framing.

51

1mm Thick Formica or equivalent laminated plastic sheeting including fixing.

52

50mm Thick Insulite woodwool-slabs including fixing.

53

32mm Thick perforated acoustic boards fixed to walls as specified.

54

50mm Thick resilient and flexible bounded fine glass fibre mat lining (density 10
3
kg/m ) and fixing to wall as specified.

55

Layer of single sided reinforced aluminium foil insulation laid to slope with 150mm
laps (measured nett-no allowance made for laps).

56

Layer of double sided reinforced aluminium foil insulation laid to slope with 150mm
laps (measured nett-no allowance made for laps).

57

50mm thick (min 10kg/m ) fibreglass insulation laid and fixed.

58

25mm Thick Rockwool or equivalent mineral woolslab sandwiched between


timber framing (measured separately).

59

50mm thick Rockwool or equivalent mineral wool slab insulation laid to fall on
roof framing (measured separately).

60

Galvanised chicken wire netting 25mm x 25mm grid, fixed with tying wire to purlins
including 150mm laps (measured nett-no allowance made for laps).

"

"

"

"

"

"

"

"

"

"

SOR BUILDING 2014/Page 20 of 40

Rate (RM)

12.50
16.50
122.00

22.40

28.80

40.00

29.70

39.70

74.80

49.90

44.90

67.30

82.20

180.70

15.60

3.50

6.90
7.50

9.10

23.80
3.01

IRONMONGERY
Item
No.

Description

Unit

Rate (RM)

Supply and fix the following ironmongery:


1

75mm Steel butt hinges (75mm x 60mm).

PR

6.10

100mm Steel butt hinges (100mm x 60mm).

PR

9.50

100mm Galvanised steel butt hinges.

PR

15.50

75mm Brass butt hinges (75mm x 60mm).

PR

14.20

100mm Brass butt hinges (100mm x 60mm).

PR

19.00

100mm Stainless steel butt hinges.

PR

23.80

75mm Counter flap brass hinges.

PR

41.10

150mm Brass cabin hook and eye.

NO

18.00

100mm Cabinet "D" handle.

NO

12.10

10

150mm Cabinet "D" handle.

NO

14.40

11

1 set 300mm standard galvanised steel adjustable friction stay.

NO

33.10

12

1 set 300mm standard stainless steel adjustable friction stay.

NO

49.90

13

Window spring catch.

NO

17.50

14

Window fastener.

NO

23.80

15

Window handle (casement window handle bronze aluminium).

NO

18.80

16

Extruded aluminium hat and coat hook with rubber buffer.

NO

21.90

17

300mm Nylon cranked pull door handle.

NO

130.90

18

200mm Surface mounted Brass barrel bolt.

NO

24.50

19

250mm Surface mounted Brass barrel bolt.

NO

31.50

20

150mm x 19mm Aluminium lever action flush bolt.

NO

28.80

21

200mm x 19mm Aluminium lever action flush bolt.

NO

33.90

22

150mm x 25mm Stainless steel flush bolt.

NO

28.40

23

300mm x 25mm Stainless steel flush bolt.

NO

39.50

24

100mm x 50mm Flush pull.

NO

24.30

25

37.50mm Brass cylinder padlock.

NO

56.20

26

50mm Brass cylinder padlock.

NO

68.60

SOR BUILDING 2014/Page 21 of 40

'

IRONMONGERY.(CONT D)
Item
No.

Description

Unit

Rate (RM)

'

Supply and fix the following ironmongery (Cont d)


27

62.50mm Brass cylinder padlock.

NO

106.00

28

Light duty door closer.

NO

130.90

29

Heavy duty door closer.

NO

186.90

30

Double action floor spring.

NO

747.30

31

40mm/38mm Diameter rubber door stop.

NO

3.70

32

Door selector.

NO

103.50

33

50mm Brass cupboard lock.

NO

26.90

34

62.50mm Cylinder sliding cupboard lock.

NO

64.50

35

Bathroom indicating bolt.

NO

52.10

36

2 lever mortice lockset (CROWN or other approved equivalent).

NO

68.60

37

2 lever rebated mortice lockset (CROWN or other approved equivalent).

NO

81.10

38

3 lever mortice lockset (CROWN or other approved equivalent).

NO

99.70

39

3 lever rebated mortice lockset (CROWN or other approved equivalent).

NO

112.10

40

Thumb turn cylinder deadlock in stainless steel finish.

NO

230.50

41

Double cylinder deadlock.

NO

249.10

42

60mm Cylindrical mortice door lock (5 pins thumb turn button).

NO

124.60

43

60mm Ditto but rebated (5 pins thumb turn button).

NO

137.10

44

70mm Brass ball catch.

NO

19.90

SOR BUILDING 2014/Page 22 of 40

STEEL AND IRONWORKER


Item
No.
1

Description

Unit

Rate (RM)

Rolled mild steel in roof trusses, braces, gusset plates, bearing plates etc.
including rivetting, welding, bolting, hoisting and fixing.

KG

Rolled mild steel in angles, joists, channels, plates, etc. including cutting, drilling,
assembling, welding, rivetting, bolting etc.

KG

8.90

Mild steel hollow sections including cutting, drilling, assembling, welding etc.

KG

8.90

1.0mm Thick galvanised steel window or door frame including cutting, drilling,
assembling, welding, rivetting, bolting etc.

8.10

28.80

Supply and fix the following mild steel bolts complete with nuts and washers:a)

19mm - 25mm Diameter bolts.

KG

15.00

b)

13mm - 16mm Diameter bolts.

KG

15.00

c)

9mm Diameter bolts.

KG

15.00

d)

8mm Diameter bolts.

KG

15.00

e)

6mm Diameter bolts.

KG

15.00

15.00

50mm x 50mm x 2mm Thick galvanised wire mesh.

50mm x 25mm x 2mm Thick galvanised wire mesh.

22.40

Pair of self finished electro galvanised steel adjustable louvre style, 4 blades and
fixing (single control).

NO

24.40

Add/deduct for each additional/less louvre blade.

NO

10

Pair of self finished galvanised pressed steel adjustable louvre style, 8 blades
and fixing (single control).

NO

28.00

Pair of self finished galvanised pressed steel adjustable louvre style, 8 blades
and fixing (double control).

NO

30.00

12

Add/deduct for each additional/less louvre blade.

NO

6.90

13

10mm Diameter mild steel burglar bars and fixing.

7.50

14

12mm Diameter mild steel burglar bars and fixing.

10.60

15

Supply and fix 1.0mm thick natural anodised aluminium side hung casement
window complete with all necessary framing and accessories (glass measured
separately) and fixing.

Supply and fix window grille comprising of 20mm x 20mm mild steel hollow
section framing infilled with 20mm x 3.2mm thick mild steel plate set in
rectangular design at 100mm centres, all welded together including painting.

11

16

SOR BUILDING 2014/Page 23 of 40

6.90

311.40

180.70

STEEL AND IRONWORKER .(CONT D)


'

I
Item
No.
17

18

19

20

21

22

Description

Unit

Supply and fix door grille comprising of 20mm x 20mm mild steel hollow section
framing infilled with 20mm x 3.2mm thick mild steel plate set in rectangular
design at 100mm centres, all welded together including painting.

Supply and fix 1.0mm thick natural anodised aluminium two panel sliding window
complete with all necessary framing and accessories, beading on top and
bottom of frame (glass measured separately) and fixing.

Supply and fix 1.0mm thick natural anodised aluminium three panel sliding door
complete with all necessary framing and accessories, beading on top and
bottom of frame (glass measured separately) and fixing.

Supply and install mild steel collapsible door including channel, tracks, guides,
etc. and fixing.

Mosquito-proof netting - aluminium wire mesh fixed (frames and beads


measured separately).

Mosquito-proof netting - nylon wire mesh fixed (frames and beads measured
separately).

SOR BUILDING 2014/Page 24 of 40

Rate (RM)

239.20

286.50

323.90
423.60
4.50
2.00

PAVIOR, PLASTERER AND TILE FIXER


Item
No.
1

Description

Unit

20mm Thick cement and sand (1:2) waterproofed rendering (Sika 1 or


'
equivalent), to manufacturer s instruction on concrete slab.

32mm Thick cement and sand (1:2) waterproofed rendering (Sika 1 or


'
equivalent), to manufacturer s instruction on concrete slab.

Rate (RM)

25.50

35.70

20mm Thick cement and sand (1:2) skirting 150mm high with rounded top edge
and coved at bottom.

16.30

20mm Thick cement and sand (1:3) rendering to floor as specified.

25mm Thick cement and sand (1:3) rendering to floor as specified.

38mm Thick cement and sand (1:3) rendering to floor as specified.

7
8

15.00

17.30

23.80

20mm Thick ditto skirting 100mm high as specified.

6.40

20mm Thick cement and sand (1:3) rendering to floor in coloured cement as
specified.

25mm Thick cement and sand (1:3) rendering to floor in coloured cement as
specified.

38mm Thick cement and sand (1:3) rendering to floor in coloured cement as
specified.

11

18.40

20.90

26.10

20mm Thick ditto skirting 100mm high as specified.

6.40

12

200mm x 200mm x 7mm Thick non-slip ceramic tiles including mortar and
screeding as specified.

13

300mm x 300mm x 8mm Thick non-slip ceramic tiles including mortar and
screeding as specified.

14

300mm x 300mm x 8mm Thick ceramic tiles including mortar and screeding as
specified.

84.80

15

100mm High skirting for 200mm x 7mm thick ceramic tiles as specified.

17.00

16

100mm High skirting for 300mm x 8mm thick ceramic tiles as specified.

18.80

17

200mm x 200mm x 7mm Thick non-slip heavy duty homogenous tiles including
mortar screed as specified.

18

300mm x 300mm x 8.5mm Thick non-slip heavy duty homogenous tiles including
mortar screed as specified.

98.30

19

100mm High skirting for 200mm x 8mm heavy duty homogenous ceramic tiles as
specified.

19.80

100mm High skirting for 300mm x 8.5mm heavy duty homogenous ceramic tiles
as specified.

21.20

10

20

SOR BUILDING 2014/Page 25 of 40

83.50

94.70

93.70

PAVIOR, PLASTERER AND TILE FIXER(CONT D)


'

J
Item
No.

Description

Unit

21

100mm x 200mm x 9mm Thick quarry tile flooring as specified.

22

Quarry tile skirting 100mm high.

23

10mm thick Selangan Batu parquet flooring of approved pattern with and
including approved adhesive on cement and sand screed (measured separately)
to floor.

24

"

"

Rate (RM)

87.70
15.00

"

87.30

"

10mm thick Kempas parquet flooring of approved pattern with and including
approved adhesive on cement and sand screed (measured separately) to floor.

81.10

"

"

31.20

550mm High riser for Selangan Batu parquet flooring with rounded top edge.

"

"

62.30

27

13mm x 75mm High timber skirting to match parquet flooring.

17.50

28

2mm Thick Vinyl tile flooring as specified including screed.

52.30

29

100mm High vinyl skirting.

15.00

30

35mm x 4mm Aluminium dividing strip fixed and cast in floor finish as specified.

13.80

31

16mm Thick cement mortar (1:6) with plasticiser plastering in two coats as
specified to walls.

12mm Thick cement mortar (1:6) with plasticiser plastering in two coats as
specified to soffit, beam etc.

33

20mm Thick cement and sand (1:3) plastering in two coats as specified on walls.

34

200mm x 200mm x 7mm Thick coloured glazed wall tiles, first quality fixed
including screed and all internal and external angles, coved and round edged
tiles and all cutting and fixing as specified.

25

275mm High riser for Selangan Batu parquet flooring with rounded top edge.

26

32

SOR BUILDING 2014/Page 26 of 40

16.30
15.00

18.80

76.60

PLUMBER
Item
No.

Description

Unit

Rate (RM)

Galvanised iron 16 gauge (1.55mm) in flashing, collars etc. including jointing and
cutting fixed as specified.

Galvanised iron 18 gauge (1.2mm) in flashing, collars etc. including jointing and
cutting fixed as specified.

Galvanised iron 16 gauge (1 .55mm) in valley gutters and gutter lining including
jointing and cutting fixed as specified.

103.90

Galvanised iron 22 gauge (0.77mm) 100mm diameter half round eave gutters
including jointing and fixing with brackets as specified.

38.10

Extra over for stopped end, angle or outlet.

NO

15.80

Galvanised iron 22 gauge (0.77mm) rainwater box gutter, 600mm girth (200mm
x 200mm) including fixing to timber and cutting hole for downpipe.

59.20

Extra over for stopped end, angle or outlet.

NO

15.90

Galvanised iron 22 gauge (0.77mm) 100mm diameter rainwater downpipe with


socketed joints, jointed in red lead and fixed to wall with pipe nails, holderbats or
brackets.

31.50

Extra over for bend, swan neck or shoes.

NO

14.20

10

Galvanised iron 22 gauge (0.77mm) 100mm x 75mm rainwater downpipe and


fixed to wall with approved holderbats.

40.80

11

Extra over for bend, shoes and short lengths.

NO

13.80

12

75mm Diameter Class B UPVC rainwater down pipe jointed with socket
connectors and fixed to wall with brackets and distance pieces.

26.00

13

Extra over for bend (elbow).

NO

18.80

14

100mm Diameter Class B UPVC rainwater downpipe jointed with socket


connectors and fixed to wall with brackets and distance pieces.

31.50

15

Extra over for bend (elbow).

NO

37.50

16

155mm Diameter Class B UPVC rainwater downpipe jointed with socket


connectors and fixed to wall with brackets and distance pieces.

50.20

17

Extra over for bend (elbow).

NO

93.40

18

150mm Half round PVC rainwater gutter including jointing and fixing with
brackets.

19

Extra for stopped end.

NO

15.30

20

Approved galvanised iron wire balloon grating and fixing to end of 100mm
diameter pipe.

NO

9.60

SOR BUILDING 2014/Page 27 of 40

97.70

88.80

43.20

PLUMBER(CONT D)
'

K
Item
No.

Description

Unit

Rate (RM)

49.90

21

50mm Diameter medium duty coated cast iron soil, waste and ventilating pipe as
specified.

22

Extra over for bend.

NO

26.80

23

50mm Diameter medium duty coated cast iron soil, waste and ventilating pipe for
45 degree Y junction with back door.

NO

52.30

24

75mm Diameter medium duty coated cast iron soil, waste and ventilating pipe as
specified.

25

Extra over for bend.

NO

35.90

26

75mm Diameter medium duty coated cast iron soil, waste and ventilating pipe for
45 degree Y junction with back door.

NO

65.50

27

100mm Diameter medium duty coated cast iron soil, waste and ventilating pipe
as specified.

28

Extra over for bend.

NO

43.20

29

100mm Diameter medium duty coated cast iron soil, waste and ventilating pipe
for 45 degree Y junction with back door.

NO

78.60

30

150mm Diameter medium duty coated cast iron soil, waste and ventilating pipe
as specified.

31

Extra over for bend.

NO

79.80

32

150mm Diameter medium duty coated cast iron soil, waste and ventilating pipe
for bend with cleaning eye.

NO

112.10

33

High Density Polyethylene Polystor (HDPE) or equivalent watertank with lid fixed
complete:-

34

76.10

94.70

140.80

a)

Size 400 gallons (nominal).

NO

996.30

b)

Size 250 gallons (nominal).

NO

622.80

c)

Size 200 gallons (nominal).

NO

523.20

d)

Size 100 gallons (nominal).

NO

255.40

NO

12.20

a) 19mm Flanged tank connection and jointed to galvanised mild steel tubing
and mild steel cistern including welding flange to and perforation in cistern.
b)

25mm Ditto.

c)

32mm Ditto.

d)

38mm Ditto.

e)

50mm Ditto.

NO
NO
NO

f) 75mm Flanged tank connection and jointed to galvanised mild steel tubing
and mild steel cistern including welding flange to and perforation in cistern.

SOR BUILDING 2014/Page 28 of 40

15.00
20.60
25.50

NO

35.80

NO

58.00

PLUMBER(CONT D)
'

K
Item
No.
35

36

37

38

Description

Unit

a) 19mm High pressure equilibrium ball valve as specified with plastic ball and
thread brazed on brass stem and body with flynut and lead washers and fixing to
cistern including drilling cistern and jointing to cold water tubing.

NO

b)

NO

25mm Ditto.

Rate (RM)

52.80
69.10

a) 19mm High pressure equilibrium ball valve as specified with blown copper
ball and thread brazed on brass stem and body with flynut and lead washers and
fixing to cistern including drilling cistern and jointing to cold water tubing.

NO

b)

25mm Ditto.

NO

195.60

c)

32mm Ditto.

NO

451.10

d)

38mm Ditto.

NO

488.20

e)

50mm Ditto.

NO

765.40

f)

75mm Ditto.

NO

1,586.30

g)

100mm Ditto.

NO

2,124.80

111.80

a) 13mm Pressure screw down stopcock and jointed to galvanised mild steel
tubing both ends.

NO

b)

19mm Ditto.

NO

16.70

c)

25mm Ditto.

NO

24.40

d)

32mm Ditto.

NO

67.00

e)

38mm Ditto.

NO

78.60

f)

50mm Ditto.

NO

116.40

11.30

a) 13mm Diameter galvanised mild steel tubing in Class "C" as specified


including couplings, connectors, bends, elbows and tees.

16.30

b)

19mm Ditto.

19.30

c)

25mm Ditto.

29.40

d)

32mm Ditto.

42.40

e)

38mm Ditto.

58.40

f)

50mm Ditto.

67.10

g)

63mm Ditto.

99.10

h)

75mm Ditto.

130.20

i)

100mm Ditto.

188.10

SOR BUILDING 2014/Page 29 of 40

PLUMBER(CONT D)
'

K
Item
No.
39

40

41

42

Description

Unit

Rate (RM)

12.50

a) 13mm Diameter galvanised mild steel tubing in Class "B" including all
necessary bends, elbows, tees, fixed complete as specified.

b)

19mm Ditto.

17.50

c)

25mm Ditto.

25.00

d)

32mm Ditto.

37.90

e)

38mm Ditto.

49.10

f)

50mm Ditto.

61.60

g)

63mm Ditto.

92.80

h)

75mm Ditto.

123.90

i)

100mm Ditto

183.40

a) 15mm Diameter UPVC pipe in Class "D" including fixing as specified.

6.50

b)

20mm Ditto.

7.50

c)

25mm Ditto.

9.50

a) 32mm Diameter UPVC pipe in Class "D" including fixing as specified.

9.30

b) 40mm Ditto.

10.90

c) 50mm Ditto.

15.60

d) 75mm Ditto.

24.30

e) 100mm Ditto.

43.60

UPVC fittings as specified:a)

15mm Diameter elbow.

NO

2.00

b)

20mm Ditto.

NO

2.60

c)

25mm Ditto.

NO

3.90

d)

32mm Ditto.

NO

5.60

e) 40mm Ditto.

NO

7.50

f)

50mm Ditto.

NO

11.30

g) 75mm Ditto.

NO

19.90

h) 100mm Ditto.

NO

38.00

SOR BUILDING 2014/Page 30 of 40

PLUMBER(CONT D)
'

K
Item
No.
43

44

45

46

Description

Unit

Rate (RM)

UPVC fittings as specified:a)

15mm Diameter bend.

NO

2.30

b)

20mm Ditto.

NO

3.10

c)

25mm Ditto.

NO

5.00

d)

32mm Diameter bend.

NO

6.80

e) 40mm Ditto.

NO

8.90

f)

50mm Ditto.

NO

13.00

g)

75mm Ditto.

NO

23.30

h)

100mm Ditto.

NO

38.50

a) 15mm Diameter tee.

NO

2.90

b)

20mm Ditto.

NO

4.30

c)

25mm Ditto.

NO

6.40

d)

32mm Ditto.

NO

8.70

e) 40mm Ditto.

NO

11.00

f)

50mm Ditto

NO

15.60

g)

75mm Ditto.

NO

28.30

h)

100mm Ditto.

NO

59.30

UPVC fittings as specified:-

UPVC fittings as specified:a)

15mm Diameter socket double end.

NO

2.80

b)

20mm Ditto.

NO

4.20

c)

25mm Ditto.

NO

5.30

d)

32mm Ditto.

NO

6.70

e) 40mm Ditto.

NO

8.70

f)

50mm Ditto.

NO

11.90

g)

75mm Ditto.

NO

14.20

h)

100mm Ditto.

NO

27.00

HDPE pipe grade PN 10 including fixing as specified:-

SOR BUILDING 2014/Page 31 of 40

PLUMBER(CONT D)
'

K
Item
No.

47

48

49

Description

51

Rate (RM)

a) 25mm Diameter.

3.90

b) 32mm Ditto.

4.50

c) 50mm Ditto.

8.10

d) 75mm Ditto.

20.90

HDPE pipe fittings as specified:a) 25mm Diameter 90 deg. Elbow.

NO

8.90

b) 32mm Ditto.

NO

11.80

c) 50mm Ditto.

NO

26.80

d) 75mm Ditto.

NO

44.90

a) 25mm Diameter equal tee.

NO

11.70

b) 32mm Ditto.

NO

15.90

c) 50mm Ditto.

NO

34.10

d) 75mm Ditto.

NO

62.30

NO

8.70

b) 32mm Ditto.

NO

11.60

c) 50mm Ditto.

NO

24.50

d) 75mm Ditto.

NO

45.60

a) 25mm Diameter Male Threaded Adaptor (MTA).

NO

6.10

b) 32mm Ditto.

NO

7.40

c) 50mm Ditto.

NO

17.50

d) 75mm Ditto.

NO

35.70

a) 25mm Diameter Female Threaded Adaptor (FTA).

NO

6.40

b) 32mm Ditto.

NO

9.00

c) 50mm Ditto.

NO

19.60

HDPE pipe fittings as specified:-

HDPE pipe fittings as specified:a)

50

Unit

25mm Diameter Straight Coupler.

HDPE pipe fittings as specified:-

HDPE pipe fittings as specified:-

SOR BUILDING 2014/Page 32 of 40

PLUMBER(CONT D)
'

K
Item
No.
52

53

Description

Unit

Rate (RM)

HDPE pipe fittings as specified:a) 25mm Diameter Reducer Coupling.

NO

8.90

b) 32mm Ditto.

NO

11.40

c) 50mm Ditto.

NO

24.70

d) 75mm Ditto.

NO

51.80

a) 150mm x 150mm Semi-recessed, white glazed vitreous china toilet roll holder.

NO

44.70

b) 150mm x 150mm Semi-recessed white glazed vitreous china soap holder.

NO

44.70

c) 300mm x 150mm White glazed vitreous china recessed combined soap dish
and sponge holder.

NO

85.10

d) 550mm x 125mm Plate glass shelf complete with chromium plated brass
brackets.

NO

41.60

brackets for fixing.

NO

71.30

f) 550mm x 400mm Bevelled edged plate glass mirror complete with 3mm thick
plywood backing and fixed with chromium plated dome headed fixing screws and
cork washers.

NO

60.80

g) 12mm Chromium plated bib tap.

NO

54.80

h) 12mm Wall mounted mixer with 150mm lever swivel anti splash nozzle or
approved equivalent.

NO

111.00

i) 576mm x 426mm Wash basin in white vitreous china complete with 13mm
chromium plated tap blank, tap hole stopper, 32mm "P" trap including 38mm
'
'
seal waste fitting with chain and plug and painted bracket support.

NO

217.70

NO

328.10

k) 500mm x 420mm Wall hung clinical wash hand basin in white vitreous china
with taphole, overflow & chainhole.

NO

1,492.80

l) White vitreous china sink size 352mm x 352mm x 228mm complete with
38mm trap including 13mm chromium plated pillar tap etc. as specified.

NO

239.40

chromium plated pillar tap etc. as specified.

NO

338.20

n) Single bowl and single drainer stainless steel sink size 900mm x 450mm x
169mm complete with 13mm chromium plated pillar tap, 38mm trap etc. as
specified.

NO

211.80

Supply and fix the following sanitary fittings:-

e) 600mm x 25mm Diameter Stainless Steel plated towel rail with ball and

j)

'

'

'

'

Ditto with two 13mm chromium plated taps, marked hot and cold .

m) Ditto size 572mm x 356mm x 235mm complete with 38mm trap, 13mm

SOR BUILDING 2014/Page 33 of 40

PLUMBER(CONT D)
'

K
Item
No.

Description

Unit

Rate (RM)

NO

381.20

p) Double bowl and double drainer stainless steel sink 1800mm x 525mm
complete with 13mm chromium plated pillar taps 38mm trap etc. as specified.

NO

436.00

q)

Squatting W.C. set including cistern as specified.

NO

348.70

r)

Pedestal W.C. set including cistern as specified.

NO

436.00

NO

1,655.80

complete with 13mm chrome plated stopcock.

NO

93.40

u) White vitreous china single urinal bowl as specified including automatic


cistern and chrome plated sparge pipes.

NO

414.90

v)

Ditto with (2) two bowls as specified.

NO

779.10

w)

Ditto with (3) three bowls as specified.

NO

983.10

x) Vitreous china urinal division size 325mm x 600mm (approximately) complete


with hangers or fixing screws.

NO

160.40

y)

Concealed Flush Valve.

NO

671.60

z)

Exposed Flush Valve.

NO

458.10

NO
NO
NO
NO
NO

1,307.70
2,092.30
3,138.40
5,056.30
10,286.80

'

Supply and fix the following sanitary fittings (Cont d):o) Single bowl and single drainer stainless steel sink size 1050mm x 450mm x
169mm complete with 13mm chromium plated pillar tap, 38mm trap etc. as
specified.

s) White vitreous china long bath 1500mm x 750mm including 2 nos. chromium
plated handles complete with wall mounted bath mixer, telephone hand shower
set with flexible hose and wall brackets and 38mm chromium plated bath pop-up
waste with overflow pipe and 'P' trap.
t)

54

100mm Diameter chromium plated shower rose and arm with swivel joint

'

Supply and lay HDPE Polysept or equivalent septic tank as per manufacturer s
instruction (cost excluding R.C slab and foundation:
a) 5 - 9 persons.
b) 9 - 16 persons.
c) 9 - 20 persons
d) 16-25 persons.
e) 25-60 persons.

SOR BUILDING 2014/Page 34 of 40

GLAZIER
Item
No.

Description

Unit

Rate (RM)

54.30

63.40

75.90

4mm Thick clear sheet glass louvre blade 150mm wide as specified.

8.90

5mm Ditto.

10.20

6mm Ditto.

11.90

4mm Thick clear float glass and glazing to wood or metal as specified.

5mm Ditto.

6mm Ditto.

10

4mm Thick clear sheet glass and glazing to wood or metal as specified.

5mm Ditto.

6mm Ditto.

64.70

79.00

89.80

4mm Thick clear float glass louvre blade 150mm wide as specified.

10.40

11

5mm Ditto.

12.50

12

6mm Ditto.

14.20

13

4mm Thick obscured glass and glazing to wood or metal as specified.

14

5mm Ditto.

15

47.70

52.10

4mm Thick obscured glass louvre blade 150mm wide as specified.

7.90

16

5mm Ditto.

8.40

17

5mm Thick grey sheet glass and glazing to wood or metal as specified.

18

6mm Ditto.

19

85.50

91.90

5mm Thick grey sheet glass louvre blade 150mm wide as specified.

13.50

20

6mm Ditto.

14.50

21

5mm Thick dark grey float glass and glazing to wood or metal as specified.

22

6mm Ditto.

23

105.20

112.30

5mm Thick dark grey float glass louvre blade 150mm wide as specified.

16.50

24

6mm Ditto.

17.60

25

6mm Thick obscured wired glass and glazing to wood or metal as specified.

26

5mm Thick tinted glass and glazing to wood or metal as specified.

27

6mm Ditto.

SOR BUILDING 2014/Page 35 of 40

237.00

66.20

76.10

PAINTER
Item
No.
1

Description

Unit

Rate (RM)

Knot, prime, stop and paint one undercoat and two finishing coats of gloss
enamel paint on woodwork.

19.90

Ditto on surfaces not exceeding 100mm girth.

2.10

Ditto exceeding 100mm and not exceeding 200mm girth.

3.10

Ditto exceeding 200mm and not exceeding 300mm girth.

5.00

Clean down, prime and paint one undercoat and two coats of gloss enamel paint
on metal surfaces generally as specified.

19.90

Ditto on surfaces not exceeding 100mm girth.

1.80

Clean down, prime and paint one undercoat and two coats of gloss enamel paint
on metal surfaces exceeding 100mm and not exceeding 200mm girth.

3.10

Ditto exceeding 200mm and not exceeding 300mm girth.

4.60

Clean down, prime and paint two coats of emulsion paint on walls and ceiling as
specified.

10

Stain and wax polish to approval on timber surfaces as specified.

11

0.00

11.30

15.00

Ditto on surfaces not exceeding 100mm girth.

2.30

12

Ditto exceeding 100mm and not exceeding 200mm girth.

4.30

13

Ditto exceeding 200mm and not exceeding 300mm girth.

6.40

14

Prepare and apply two coats of floor dressing on parquet or other timber flooring.

15

Wood preservative, two coats on timber as specified.

16

Prepare and apply two coats of acrylic co-polymer resin based paint ( Sandtex
"
Matt or equivalent) on walls and soffits.

Prepare, stain to approval and apply three coats of varnish on surfaces of


woodwork.

17.50

18

Ditto on surfaces of woodwork not exceeding 100mm girth.

2.00

19

Ditto exceeding 100mm and not exceeding 200mm girth.

4.60

20

Ditto exceeding 200mm and not exceeding 300mm girth.

5.00

21

Prepare and apply two coats of flame retardant paint (up to 600 degrees) on
metal surfaces.

Prepare and apply two coats of silicone-based water repellent solution on fairface concrete and brickwork surfaces.

17

22

31.20

7.50

"

SOR BUILDING 2012/Page 36 of 40

22.40

31.20
13.80

ROAD, CULVERT, FENCING, TURFING AND ROADSIDE DRAINS

Item
No.

Description

Unit

Rate (RM)

Roadwork
2

3.10

50mm Thick sand spread, levelled and compacted to falls and cambers.

250mm (finished) Thick crusher run base course in two layers as specified
spread and levelled.

300mm Thick crusher run spread, levelled and compacted to falls and cambers.

87.50mm (finished) Thick layer of wearing course consisting of two layers as


specified, the first layer 62mm thick made up to 37.50mm - 62.50mm aggregate
and the 2nd layer 25.50mm thick made up of 25mm - 37.50mm aggregate, each
layer spread and levelled and well rolled and compacted.

50mm Thick asphaltic concrete wearing course, spread, levelled and compacted
to an even gradient and crossfalls.

40mm Ditto.

Apply one coat of 80/1 00 penetration bituminous binder seal as specified, at the
rate of 4.08 litres per square meter on wearing course, including blinding with
19mm (nominal) aggregate and rolled.

Ditto but at the rate of 1.36 litres per square meter ditto.

Provide and lay 37.50mm thick premix carpet course consisting of stones of
maximum size 19mm and including a layer of bituminous emulsion tack coat
applied at a rate of 0.435 litres per square meter.

25.00

Prepare and apply 2 coats approved road line paint as specified on premix road,
100mm wide.

1.70

3mm thick road markings (measured nett) and direction arrows in thermoplastic
paint.

22.40

300mm x 150mm x 600mm Precast reinforced concrete (Grade 25) as specified


kerb finished fair on exposed surfaces, bedded, jointed and pointed in cement
mortar (1:3) including all necessary excavation, formwork and painting as
specified.

59.90

300mm x 150mm x 600mm Precast reinforced concrete (Grade 25) as specified


kerb with scupper opening finished fair on exposed surfaces, bedded, jointed
and pointed in cement mortar (1:3) including all necessary excavation, formwork
and painting as specified.

64.40

100mm x 300mm x 600mm Precast reinforced concrete (Grade 25) as specified


kerb with splayed top finished fair on exposed surfaces, bedded, jointed and
pointed in cement mortar (1:3) including all necessary excavation, formwork and
painting as specified.

53.90

10

11

2
2

12.50
18.80

51.30

29.30

23.40

6.40
4.00

Road Kerb
12

13

14

SOR BUILDING 2014/Page 37 of 40

ROAD, CULVERT, FENCING, TURFING AND ROADSIDE DRAINS. (CONT D)


'

N
Item
No.

Description

Unit

Rate (RM)

Culvert
3

274. 10

311.40

43.60

450mm Diameter precast reinforced spun concrete pipe type "S" and jointing
with and including precast concrete collars in cement mortar (1:1) including
forming fillet all round at each end of collars.

355. 10

19

600mm Ditto.

480.80

20

750mm Ditto.

575.50

21

900mm Ditto.

706.30

22

1200mm Ditto.

950.40

23

600mm x 600mm Box culvert including excavation and backfilling with approved
materials, concrete collars, handling, jointing, concrete bedding.

485.80

24

750mm x 600mm Ditto.

934.20

25

900mm x 750mm Ditto.

1,120.90

26

900mm x 900mm Ditto.

1,289.10

27

1200mm x 1200mm Ditto.

1,650.30

28

1500mm x 1200mm Ditto.


M

2,023.80

Chain link fencing 1.50m high consisting of 50mm x 50mm x 6mm painted steel
angle post at 3.00m centres with bottom end embedded in concrete (Grade 20)
and with 50mm diamond mesh (No.10 S.W.G.) galvanised chain link fence,
including three strands of No.8 galvanised straining wire and including 50mm x
50mm x 6m painted steel angle corner struts with bottom end embedded in and
including concrete (Grade 20) base.

106.00

30

Ditto 50mm diamond mesh (No.12 S.W.G.) ditto.

112.10

31

Ditto 65mm diamond mesh (No.10 S.W.G.) ditto.

99.70

32

Ditto 65mm diamond mesh (No.12 S.W.G.) ditto.

106.00

33

Extra over last 4 items for chain link fencing 1 .8m high having three (3) strands
of two ply barb wire (13 gauge with 4 pointed barb at 75mm) on top.

18.90

15

Concrete (Grade 20) in culvert base, surround etc.

16

Reinforced concrete (Grade 25) in culvert base, surround, head and wing walls.

17

Sawn formwork to culvert base, surround, head and wing walls.

18

Fencing
29

SOR BUILDING 2014/Page 38 of 40

ROAD, CULVERT, FENCING, TURFING AND ROADSIDE DRAINS. (CONT D)


'

N
Item
No.

Unit

Rate (RM)

PVC coated Chain link fencing 1.50m high consisting of 50mm x 50mm x 6mm
painted mild steel angle post at 3.00m centres with bottom end embedded in
concrete (1:3:6-25mm aggregate) and with 50mm diamond mesh (No. 10
S.W.G.) pvc coated chain link fence, including three strands of No. 8 galvanised
straining wire and including 50mm x 50mm x 6mm painted mild steel angle
corner struts with bottom end embedded in and including concrete (1:3:6-25mm
aggregate) base.

109.10

Mild steel double leaf gate size 4.90m wide x 1 .50m high overall, each leaf
comprising of 150mm wide frame constructed of 3mm thick mild steel plate
welded to and including 2 No 25mm x 25mm x 3mm mild steel hollow section
closed at ends with 6mm thick mild steel plate, top and bottom rails constructed
of 2 No 3mm thick mild steel plate welded to and including 2 No 50mm x 25mm
x 3mm thick mild steel hollow section closed at ends with 6mm thick mild steel
plate, infilled with 20mm x 20mm mild steel hollow section vertical members at
125mm centres closed at ends with 6mm mild steel plate, with and including mild
steel bolt and sleeve, lock plate, butt hinges, welding and painting.

NO

2,671.50

36

Mild steel single leaf gate size 1.05m wide x 1.50m high ditto.

NO

645.30

37

Mild steel sliding gate size 6.0m wide x 1.80m high, constructed of 100mm x
50mm mild steel hollow gate frame all around including intermediate framing to
be welded together to infilled with 25mm x 25mm mild steel hollow at 150mm
centres, fixing all members together, filling all welds smooth complete with
sliding gate roller track and painting with one coat metallic primer and three coat
alkali resin base paint or equivalent and approved and all necessary works for
proper completion.

NO

4,119.40

34

35

Description

Turfing
38

Spot turfing on level surfaces at 450mm centres in chequered pattern and


including 50mm bed of black earth as specified.

Close turfing on level surfaces and including 50mm bed of black earth as
specified.

Close turfing to banks on and including 50mm bed of black earth and pegging,
all as specified.

4.20

6.20

6.60

9.70

300mm x 300mm Precast reinforced concrete semi elliptical channel 75mm thick
including all necessary excavation.

31.20

43

375mm x 375mm Ditto.

43.60

44

450mm x 450mm Ditto.

56.20

45

600mm x 600mm Ditto.

87.30

39

40

41

Turfing for playing fields including site preparation, 100mm thick river sand,
100mm thick top soil, turfing with an average 50mm thick earth bed, compaction,
watering, weed control, mowing and top dressing all as specified.
Roadside Drains

42

SOR BUILDING 2014/Page 39 of 40

ROAD, CULVERT, FENCING, TURFING AND ROADSIDE DRAINS. (CONT D)


'

N
Item
No.
46

47

Description

50mm Thick precast concrete cover slab 300mm wide cast in approximately
600mm length, notched at ends and reinforced with and including one layer of
150mm (6G) x 150mm (6G) steel fabric reinforcement and placing in position.

Unit

60mm Thick approved interlocking concrete paver block as specified, laid on and
including 30mm thick sand and 60mm thick hardcore bed and all necessary
'
excavation, all in accordance with the manufacturer s instruction and as
specified.

48

80mm Ditto.

49

100mm Ditto.

Rate (RM)

27.40

52.30

77.00
81.10

Gabion
50

Supply and lay 2.0m x 1.0m x 1.0m PVC Coated wire mesh rock filled gabion
mattress.

NO

445.10

Mild Steel Grating


230mm x 600mm Mild steel grating drain cover with welded connection,
comprising 50mm x 50mm x 6mm thick angle all round, infilled with 40mm x
6mm thick flats at 30mm centres, painted with one coat red oxide primer; set in
and including forming rebate at top of drain.

NO

57.30

52

600mm x 600mm Ditto.

NO

137.10

53

1200mm x 1200mm Ditto.

NO

530.60

54

850mm x 850mm Mild steel grating as sump cover ditto.

NO

269.00

51

SOR BUILDING 2014/Page 40 of 40

You might also like