bottom-line advantage, but where two-phase flow is an integral part of the process or it is
necessary to begin with an empty or partially filled flow tube.
Making matters worse, entrained air may not emerge as the culprit until after a frazzled
process engineer has invested many hours trying to figure out why he can't get the results
he needs. Our own analysis shows up to 92% of all Coriolis measurement problems are
due to entrained air or gas, yet in the vast majority of cases, users don't recognize twophase flow as the problem.
Patented and advanced control
Coriolis technology is highly accurate in single-phase flow, with perhaps a 0.1% error
level. Two-phase flow can boost the error rate to 20% or higher. Following are some of
the profitability drains that inaccurate flow measurement causes:
Lost production: In flow-intensive operations, thousands of dollars' worth of lost
production can pass undetected in minutes.
Inaccurate pricing: In custody transfer applications, where measured amount transferred
defines payment price, faulty measurements raise financial havoc on either end of the
transfer.
Excess downtime: When traditional Coriolis meters encounter entrained air, they render
inaccurate measurements, and if the condition persists, will shut down. This cuts into
valuable production time.
To determine the extent of the problem and find a cost-effective solution, Invensys
commissioned a survey of process engineers. This revealed entrained air was indeed a
major problem in the industry, and what customers really wanted was a cost-effective
meter that provides accurate measurement despite the presence of air. Invensys
collaborated with researchers at Oxford University in England to develop digital
technology for accurate measurement of flow, even when the flow tube contains
entrained air.
Working closely with the Oxford researchers, our engineers developed a transmitter that
applied the Oxford measurement principles. The resulting patented product incorporates
new signal processing techniques to provide useful measurements of both mass flow and
density and the operational aspects of keeping the Coriolis meter running stably in singlephase or two-phase flow conditions.
One of the many patents it has received involves an advanced control and measurement
system with high-speed digital signal processing that responds to changing flow
conditions many times faster than standard Coriolis flowmeters. Another patent relates to
detecting and compensating for two-phase flow conditions and generating a validated
mass flow measurement.
Unloading railcars and trucks
Coriolis meters measure the mass flow of materials, which is independent of other
physical parameters, as well as the ambient conditions in which the measurement takes
place. Therefore, the measurement is unaffected by changes in temperature, pressure,
density, viscosity, and flow profile. With the ability to handle two-phase flow and
compensate for physical conditions, the advanced Coriolis flowmeters have greatly
expanded fluid metering applications, including traditionally difficult situations, such as
custody transfer, proving, tank truck, and tanker loading and unloading, and applications
where two-phase flow is an integral part of the process.
Accurate measurement at custody transfer points is critical as competitive market
conditions drive companies to develop operations that are more efficient. By minimizing
wasted materials left on the bottom of transport vessels and improving transfer yields,
advanced Coriolis flowmeters provide more accurate material accountability, which is a
direct contribution to bottom line performance. This is a win-win situation for both
entities involved in the transaction. Advanced Coriolis technology is increasingly
replacing positive displacement meters for custody transfer to attain the benefits of
Coriolis accuracy, while reducing total cost of ownership. With no moving parts in the
fluid stream, Coriolis meters require little-to-no maintenance and are easy to install.
In pipeline flow measurement-proving applications, the frequency and duration of
calibration can hinder productivity. Advanced digital Coriolis flowmeters offer a solution
by providing a much faster response time, and greater accuracy and repeatable proving
with small volume provers. A proving run may take as little as 20 seconds. This is
particularly beneficial in multi-product pipeline applications where fluids varying from
light, liquefied petroleum gases to heavy crude oils pass through a common flowmeter.
For these applications, flowmeters often take place several times a day, so slashing each
proving process to seconds can significantly boost productivity.
Another issue is unloading railcars and tank trucks until they are practically dry. To
empty out the tank completely, invariably introduces air as the level approaches bottom.
Exacerbating this is that in most cases, unloading happens at as high a flow rate as
possible to speed up the process. This high flow rate tends to suck air into the flowmeter.
Where a conventional Coriolis meter would shut down in this situation, advanced
Coriolis meters continue to provide a useful flow measurement, enabling faster, more
complete unloading of tank trucks and railcars. Even with the flow tube empty, they
respond 10 times faster than traditional Coriolis transmitters, which reduce startup time
while increasing production throughput and profitability.
Innovative moneymakers
In addition to improving existing flow measurement applications, advanced Coriolis
technology is opening new doors for improving process efficiencies where two-phase
flow is an integral part of the process.
For instance, using carbon dioxide (CO2) for enhanced oil recovery (EOR) can increase
output by as much as 12%. However, accurate measurement of CO2 has been the
weakness of the process. A large midstream energy company found the solution by