PROJECT

Bian Municipal Hall Annex

LOCATION

Barangay Zapote, Bian, Laguna

OWNER

Municipality of Bian

PROJECT SPECIFICATIONS
1. CONSTRUCTION GUIDELINES
1.1

The site and the building shall be thoroughly examined in


relation to all conditions, which may directly affect the
contract work. Proposed bid must fully reflect all such
affecting conditions and duly noted on the bid.

1.2

The contractor shall be responsible, during and prior to


construction for verifying all the dimensions, which may
affect the work.

1.3

Any doubt as to the true meaning and intent of the bid plan
and specifications or any obscurity in the wording of this bid
form shall be referred to the owner or his authorized
representative for interpretation. The decision of the owners
authorized representative on the discrepancies so as to
conform to the real intent on the drawings and specifications
shall govern to carry out the work in the most satisfactory
manner.

1.4

The specifications cover the necessary materials and intend


to specify their brands, size, kind or type and other relative
details including workmanship required to construct the
proposed structure in the conformity with the plans and
drawings. Any discrepancies in types and brands of materials
used or installed during actual construction shall be rejected
unless with written approval of owner or his authorized
representative.

1.5

All works shall be done and executed in the highest quality


of workmanship.

1.6

It is understand that the work shall be done and executed in


accordance with the understand engineering method and
regulations with the building code and requirements as
called for by design of the project in the strict compliance to
this specifications and drawings.

Page 1 of 4
Project Specifications

1.7

The contractor is required to send in their carpentry/masonry


including painting and plumbing foreman/leadman for a preconstruction meeting and interview with the OWNER and his
authorized project supervisor prior to start of construction.

2. TURNOVER OF PROJECT
2.1 General Cleaning/Clearing of site and its surrounding area
prior to turnover of project.
2.2 The contactor shall be directly responsible in coordination
with the owner for the completion of the proposed project.

3. MATERIALS AND SPECIFICATIONS


3.1 Portland : REPUBLIC, RIZAL ISLAND or imported cement
conforming to standard specifications for Portland cement (ASTM
Designation C150 latest revision type 1 Portland cement)
3.2 Reinforcing steel bars : Intermediate grade conforming to the
latest edition of ASTM Designation (A615-68 Grade 33) A36.Mild
Grade.
3.3 Concrete Aggregates : Well graded, clean particles of gravel or
crushed rock conforming to the STANDARD specification for
concrete Aggregates ASTM Designation C-33 latest edition.
3.4 Mortar and Grouts : Conforming (ASTM 90) requirements of
NSCB.
3.5 Concrete Works : Conforming to latest edition of NSCB, ACI 31883.
3.6 Sand : White sand conforming to ASTM C35-67
3.7 Concrete Hollow Block : Conform to ASTM 90.
3.8 Lumber :
3.8.1

3.8.2
3.8.3

Seasoned Tanguile or Yakal or Guijo with coal


tar: Door Jambs, wood plates and all other wood
works in contract with concrete.
Kiln-dried Tanguile, doors and trims and nailers.
thick marine Plywood for cabinet works.

3.9 Metal Works : Stair Hand Railing


4. ROOFING
Page 2 of 4
Project Specifications

4.1 G.A. 24 Pre-painted Standing Seam Long Span G.I.


4.1.1 Steeltech Flashing
4.1.2 Steeltech Gutter
4.1.3 Steeltech Fascia flashing
5. DOORS
5.1 Tanguile Panel Door
5.1.1 Accessories
5.1.1.1 Lockset
5.1.1.2 Hinges
5.2 MIGHTY DOORS PVC Type Door
5.2.1 Accessories
5.2.1.1 Lockset
5.2.1.2 Hinge
5.3 Steel-framed Glass Type Door
5.3.1 Accessories
5.3.1.1 Lockset
5.3.1.2 Hinge
6. WINDOWS
6.1 Casement Type Window Panel with 6mm thick. Tinted Annealed
glass on Aluminum frames in Analok Finish
7. PLUMBING
7.1 Cold Water Lines
7.2 Vent Lines
7.3 Waste Line
7.4 Storm Drains
7.5 Water Meter
7.6 Valves
7.7 Fixtures
7.7.1
7.7.2
7.7.3
7.7.4
7.7.5
7.7.6
7.7.7
7.7.8

THERMOVAR G.I. Pipe


MOLDEX or DURAFLEX Sch. 40,
PVC pipes. SDR 21
MOLDEX or DURAFLEX Sch. 40,
PVC pipes. SDR 21
MOLDEX or DURAFLEX Sch. 40,
PVC pipes. SDR 21
MECO
NELTEX or RED and WHITE
Water Closet
Lavatory
Faucets
Flush Valve
Shower Head
Shower Valve
Kitchen Sink
Floor Drain

HCG
HCG
HCG
HCG
HCG
HCG
HCG
HCG

8. ELECTRICAL
8.1 Wires & Cables

DURAFLEX
Page 3 of 4

Project Specifications

8.2 Intermediate Conduit


8.3 Electrical Metallic Tubing
8.4 Circuit Breaker
8.5 Wiring Devices
8.5.1
8.5.2
8.5.3

NELTEX or EMERALD
RSC Rigid Steel Conduit
GENERAL ELECTRIC (GE)

Plates
NATIONAL
Receptacles NATIONAL
Switch
NATIONAL

8.6 Lighting Fixtures


8.7 Panel Board
8.8 Switches

NATIONAL
GENERAL ELECTRIC (GE)
NATIONAL

9. PAINTING
9.1 BOYSEN or other similar approved brands
9.2 CORROLES : Anti-rust coating for structural steel and expanded
wire mesh
10.MECHANICAL
10.1900x2100mm TOSHIBA Millennium Classic S1 Elevator
10.225mm Condensate Drain Pipe
10.325mm thick pre-formed Elastomeric closed cell tube insulation
10.4Polyethylene blue film tape vapor barrier
10.519mm closed cell thermal elastomeric rubber insulation
SCHEDULE OF FINISHES
1.0 FLOOR FINISHES
1.1 Adhesive , Grouting and installation , use ABC
1.2 8 x 8 (0.20m x 0.20m) EUROTILES tiles for toilet
1.3 12 x 12 (0.31m x 0.31m) EUROTILES tiles for countertops
1.4 18 x 18 (0.46m x 0.46m) EUROTILES tiles for offices
2.0 WALL FINISHES
2.2

2.1 Gloss Latex paint on plain cement finish for interior walls
8 x 8 (0.20m x 0.20m) EUROTILES tiles for toilet
2.3 Plain cement plaster in textured paint finish with 12mm x 12mm
grooves for exterior walls
2.4 6mm thick Ribbon graine Tanguile Plywood wall panels
3.0 CEILING FINISHES
3.1 12mm thick closed jt. Gypsum board painted finnish on steel furring
channels

Page 4 of 4