You are on page 1of 82

SCHEDULE

Room Size
Area

No of Air
Change

Air volume
to be
replaced

Length
(m)

Width
(m)

Height
(m)

Elevator M/C
Room

3.500

3.500

4.350

20

1070

Emergenc
y Stair

5.395

3.580

17.850

10

3450

Battery
Room

6.670

6.870

4.850

10

2230

Toilet

3.235

2.585

4.850

10

410

Pantry

1.770

2.585

4.850

20

450

Store

2.885

2.585

4.850

10

370

6500

TG Building

Turbine Building
Ground Floor

Turbine Building
Operating Floor

Turbine Building
Deaerator Floor

AHU Room'
Supply Fan

for

CW Pump
House

31.500

9.550

7.850

10

23620

8.000

9.550

4.350

15

4990

22.000

24.000

8.850

10

46730

MCC Room
14.000
(Gr. Floor)

8.000

4.850

15

8150

MCC Room
20.000
(1St Floor)

8.000

3.850

15

9240

Toilet
(Gr.
Floor)

3.500

2.500

4.850

10

430

Toilet
(1st
Floor)

3.500

2.500

3.850

10

340

Chemical
Building
(Gr. Floor)

20.000

20.000

4.850

10

19400

Chemical
Building
(1st Floor)

20.000

20.000

3.850

10

15400

MCC Room

6.000

4.000

4.850

15

1750

CW Pump House
Switch
Gear Room

DM
Building

DM Plant

PT Plant

SCHEDULE

for

VENTILATION
Fan Details

No. of
Fans

Fan capacity
considering
10% margin
(M3/Hr)

Fan
capacity
seleted
(M3/Hr)

Head
Required
(mmWC )

Fresh Air supply thru' wall


mounted fan filter unit &
exhaust thru' back draft
damper

1177

1200

30

Air exhaust through wall


mounted exhaust fans.

1898

1900

15

Air exhaust through wall


mounted exhaust fans.

2453

2500

15

Air exhaust through wall


mounted exhaust fans.

451

500

15

Air exhaust through wall


mounted exhaust fans.

495

500

15

Air exhaust through wall


mounted exhaust fans.

407

500

15

Air exhaust through wall


mounted exhaust fans.

3575

3600

15

Type of Ventilation

Air exhaust through wall


mounted exhaust fans.

5196

5200

15

Supply Air System with


back draft damper

2745

2800

30

Air exhaust through wall


mounted exhaust fans.

7343

7400

15

Supply Air System with


back draft damper

2988

3000

30

Supply Air System with


back draft damper

2033

2100

30

Air exhaust through wall


mounted exhaust fans.

473

500

15

Air exhaust through wall


mounted exhaust fans.

374

400

15

Air exhaust through wall


mounted exhaust fans.

5335

5400

15

Air exhaust through wall


mounted exhaust fans.

4235

4300

15

Supply Air System with


back draft damper

1925

2000

30

Fan Details

Type

Required
Rated
Break Capacity with
Power
25% margin
(in KW)
(in KW)

Wall mounted axial


type with rain cowl
& bird screen

0.245

0.306

Wall mounted axial


type with rain cowl
& bird screen

0.194

0.242

Wall mounted axial


type with rain cowl
& bird screen

0.255

0.319

Wall mounted axial


type with rain cowl
& bird screen

0.051

0.064

Wall mounted axial


type with rain cowl
& bird screen

0.051

0.064

Wall mounted axial


type with rain cowl
& bird screen

0.051

0.064

Wall mounted axial


type with rain cowl
& bird screen

0.368

0.459

Wall mounted axial


type with rain cowl
& bird screen

0.531

0.664

Wall mounted axial


type with rain cowl
& bird screen

0.572

0.715

Wall mounted axial


type with rain cowl
& bird screen

0.755

0.944

Wall mounted axial


type with rain cowl
& bird screen

0.613

0.766

Wall mounted axial


type with rain cowl
& bird screen

0.429

0.536

Wall mounted axial


type with rain cowl
& bird screen

0.051

0.064

Wall mounted axial


type with rain cowl
& bird screen

0.041

0.051

Wall mounted axial


type with rain cowl
& bird screen

0.551

0.689

Wall mounted axial


type with rain cowl
& bird screen

0.439

0.549

Wall mounted axial


type with rain cowl
& bird screen

0.408

0.510

AIR WASHER SIZING CALCULATION


Room Size
Area

Length
(m)

No of Air
Change

Air volume
to be
replaced

Width
(m)

Height
(m)

16.905

4.785

4.850

2360

9.160

11.320

4.850

3020

Cable Cellar

56.710

6.770

3.850

8870

Cable Cellar
Extension

26.295

11.550

3.850

7020

BD Bay (Column
Number 10-11)

19.792

7.745

2.350

2170

CD Bay (Column
Number 1-1')

8.240

8.095

2.350

950

65.700

16.100

4.850

30790

A. TG Building Electrical Room


Reactor Room

Turbine Building
Ground Floor
EL(+)00.00 M
Dry Transformer
Room

Turbine Building
Mazzenine Floor
EL(+)05.00 M

B. Other Rooms of TG Building


Turbine Building
AB Bay
Ground Floor
EL(+)00.00 M

Turbine Building
Mezzanine Floor AB Bay
EL(+)05.00 M

65.700

16.100

4.850

30790

AB Bay

65.700

16.100

7.500

47600

BC Bay:
Electrical
Maintenance
Room

8.240

7.865

5.350

2090

BC Bay (Column
1-1')

8.240

7.805

4.850

1880

Air Washer
Room

8.240

7.865

5.350

2090

Air Washer
Room

8.240

7.865

5.350

2090

Turbine Building
Operating Floor
EL(+)09.00 M

Turbine Building
Deaerator Floor
EL(+)14.50 M

Total Air Quantity to be Handled

141720 CMH

Considering 10% Margin

155892

No. of Washer unit considered

Capacity of each Washer unit

80000 CMH

KW Required for Each Washer Unit

46.92 KW

Considered KW

55 KW

No. of Roof Extractor Considered

Capacity of Each Roof Extractor

16000 CMH

KW Required for Each Washer Unit

3.75 KW

Considered KW

5.5 KW

DUCT SIZING
CFM
Number
Duct
CFM
Capacity
Duct
of
Area %
Capacit
% for
Area in
Opening
(Refer
y%
each
Sq. Inch
provided
Table 13)
Opening

1.67

11.5

4.43

2.13

11.5

4.43

6.26

11.5

4.43

4.95

11.5

4.43

1.53

11.5

4.43

0.67

11.5

4.43

21.73

11.5

4.43

Dimension (Ref. Table


6)
Length
in Inch

Total CFM

Total CFM

21.73

34.5

13.29

33.59

17.5

6.74

1.47

3.5

1.35

1.33

3.5

1.35

1.47

3.5

1.35

1.47

3.5

1.35

141720

200

38.52

70860

100

19.26

28

10.87

116

5.43631872

52

80000

11

21.75

DUCT SIZING

imension (Ref. Table


6)
Width
in Inch

Velocity
Considered
(m/sec)

Duct
Area
(sq. ft.)

Number
of
Branch

11

0.64

1.00

Each
Duct Size
Duct
Length Width
Area
in Inch in Inch
(sq. ft.)

1.46
11

0.82

11

2.41

11

1.91

1.00

2.67
11

0.59

11

0.26

11

0.57

0.57

10

10

11

0.57

0.57

10

10

11

19.26

19.26

10

10

136

24

2900

600

24

1300

600

IF

NUMBER OF BRANCH

MM

MM

SQ. INCH

Inch

Inch

2900

600

3.624

34

24

IF
SQ. INCH
1.208

3
Inch

18

NUMBER OF DISTRIBU
Inch

16

NUMBER OF BRANCH TAKE OUT FROM COMMON HEADER


MM

MM

850

600

NUMBER OF DISTRIBUTION FROM EACH BRANCH TAKE OUT


MM
MM
450
400

2 X 12 MW CPP
AIR CONDITIONING AREA
SL.
LENGTH
AREA
NO.
(M)
1 CCR + CER
50

WIDTH
(M)
7

HIGHT
(M)
4

350
350 3767.369

VENTILATION AREA
SL.
NO.

AREA

TG Building Electrical Room

1
2
3
4
5

Gr. Floor (EL 0.0M)


Battery Room EL 0.0M
Electrical Room at EL 0.0M
Extention of electrical room at
EL (0.0M) (CD)
GT1 room at EL (0.0M)
GT2 room at EL (0.0M)
Mezzanine Floor (EL 5.0M)

LENGTH

WIDTH

HIGHT

8
50

7
7

5
5

27

11.5

18.5
7

8
8

9
9

280
1750
1552.5
1332
504

Cable Spreader Room EL 5.0M

58

Cable Spreader Room EL 5.0M

34

11.5

Operating Floor (EL 9.0M)


SWGR room EL 9.0M

26

11.5

1196

Other Room of TG Building


65

15

4875

65

15

4875

65

15

11

10725

280

224

16

448

5.5

308

5.5

308

5.75

5.5

253

1
2
3
4
5
6
6
6

AB Bay Ground Floor EL 0.0M


AB Bay Mezzanine Floor EL
5.0M
AB Bay Operating Floor EL
9.0M (upto EL 20.0M)
BC Bay Ground Floor EL 0.0M
BC Bay Mezzanine Floor EL
5.0M
BC Bay Operating Floor EL
9.0M
BC Bay Deaerator Floor EL
14.5M (AW 1 for AB bay)
BC Bay Deaerator Floor EL
14.5M (AW 2 for AB bay)
CD Bay Deaerator Floor EL
14.5M (AW for Electrical room)

1624
1564

32098.5
No of Air Washer Unit

Roof extractor

Power
37.67369

Total Ventilation
192591
3

40 TR

60

Considered
200000
70000

Power
Kw
41.06

170

26250

6.16

10

AIR WASHER SIZING CALCULATION


Room Size
Area

Length
(m)

No of Air
Change

Air volume
to be
replaced

Width
(m)

Height
(m)

57.100

6.670

4.850

11090

16.905

4.785

4.850

2360

9.160

11.320

4.850

3020

Cable Cellar

56.710

6.770

3.850

8870

Cable Cellar
Extension

26.295

11.550

3.850

7020

BD Bay (Column
Number 10-11)

19.792

7.745

2.350

2170

CD Bay (Column
Number 1-1')

8.240

8.095

2.350

950

26.000

11.370

3.850

6830

A. TG Building Electrical Room


Electrical Room

Turbine Building
Reactor Room
Ground Floor
EL(+)00.00 M

Dry Transformer
Room

Turbine Building
Mazzenine Floor
EL(+)05.00 M

Turbine Building
Switchgear
Operating Floor Room
EL(+)09.00 M

B. Other Rooms of TG Building


Turbine Building
AB Bay
Ground Floor
EL(+)00.00 M

65.700

16.100

4.850

30790

Turbine Building
Mezzanine Floor AB Bay
EL(+)05.00 M

65.700

16.100

4.850

30790

AB Bay

65.700

16.100

7.500

47600

BC Bay:
Electrical
Maintenance
Room

8.240

7.865

5.350

2090

BC Bay (Column
1-1')

8.240

7.805

4.850

1880

65.575

6.770

5.350

Turbine Building
Air Washer
Deaerator Floor Room
EL(+)14.00 M

8.240

7.865

5.350

2090

Air Washer
Room

8.240

7.865

5.350

2090

Turbine Building
Operating Floor
EL(+)09.00 M

BC Bay

Total Air Quantity to be Handled

159640 CMH

Considering 10% Margin

175604

No. of Washer unit considered

Capacity of each Washer unit

90000 CMH

KW Required for Each Washer Unit

52.79 KW

Considered KW

55 KW

No. of Roof Extractor Considered

Capacity of Each Roof Extractor

18000 CMH

KW Required for Each Washer Unit

4.22 KW

Considered KW

5.5 KW

DUCT SIZING
CFM
Number
Duct
CFM
Capacity
Duct
of
Area %
Capacit
% for
Area in
Opening
(Refer
y%
each
Sq. Inch
provided
Table 13)
Opening

Dimension (Ref. Table


6)
Length
in Inch

Total CFM

Total CFM

Total CFM

42310

27.21

11.5

3.54

27.21

34.5

10.61

42.07

11

17.5

5.38

1.85

3.5

1.08

1.66

3.5

1.08

11

30.76

15.38

113150

117330

116

Total CFM

90000

FOR NON-ELECTRICAL ROOMS


Total CFM

113150

11

30.76

15.38

116

24

2900

600

7.68899329

52

24

1300

600

DUCT SIZING

imension (Ref. Table


6)
Width
in Inch

Velocity
Considered
(m/sec)

Duct
Area
(sq. ft.)

11

3.01

11

0.64

Number
of
Branch

Each
Duct Size
Duct
Length Width
Area
in Inch in Inch
(sq. ft.)

1.51

1.46
11

0.82

11

2.41

11

1.91
2.67

11

0.59

11

0.26

11

1.86

1.86

11

11.50

11.50

11

0.00

0.00

11

0.57

0.57

10

10

11

0.57

0.57

10

10

11

31.89

24

31.89

11

24.46

Inch

Inch

24.46

144

30

12.231717

88

24

IF

NUMBER OF BRANCH

MM

MM

SQ. INCH

Inch

Inch

2900

600

5.126

34

24

IF
SQ. INCH
1.709

3
Inch

18

NUMBER OF DISTRIBU
Inch

16

MM

MM

MM

MM

3600

750

2200

600

NUMBER OF BRANCH TAKE OUT FROM COMMON HEADER


MM

MM

850

600

NUMBER OF DISTRIBUTION FROM EACH BRANCH TAKE OUT


MM
MM
450