DRY684C
DRY688C
D715I
Table of Contents
Section 1 Safety Information
Locating an Authorized Servicer ............................4
Section 2 Introduction
Customer Service ....................................................5
Nameplate Location ................................................5
Model Identification ................................................6
How Your Dryer Works ..........................................7
Section 3 Troubleshooting
1. Dryer Motor Does Not Run .............................9
2. Dryer Stops In Cycle; Quits After The First Few
Loads; Has A Burning Smell; Cycles On Motor
Thermal Protector .........................................10
3. Dryer Motor Runs But Cylinder Does
Not Turn ........................................................11
4. Dryer Motor Does Not Stop ..........................11
5. Dryer Runs Only When Door is Open ...........12
6. Dryer Heating Assembly Does Not Heat or
Burner Does Not Ignite .................................12
7. Igniter Does Not Glow (Gas Supply Sufficient)
Gas Dryer Models .......................................13
8. Burner Ignites And Goes Out Repeatedly
Gas Dryer Models .......................................13
9. Igniter Glows But Burner Does Not Ignite
Gas Dryer Models .......................................13
10. Dryer Heater Assembly Or Burner Shuts Off
Prematurely ....................................................14
11. Dryer Heater Assembly or Burner Repeatedly
Cycles Off On Limit Thermostat ...................14
12. Dryer Heater Assembly or Burner Does
Not Shut Off ...................................................15
13. Clothes Do Not Dry in Dryer .........................15
14. Timer Does Not Advance In Automatic
Cycle ..............................................................16
15. Clothes Are Too Hot When Removed From
Dryer ..............................................................17
16. Excessive Chattering Or Vibrating Noise
in Dryer ..........................................................17
17. Excessive Humming Or Whistling Noise
in Dryer ..........................................................17
Section 4 Grounding
18. Ground Wires From Power Cord To Rear
Bulkhead And From Rear Bulkhead To Control
Cabinet Check Wall Receptacle Polarity (Gas
Dryer Models Only) .......................................19
19. Ground Wire From Terminal Block To Rear
Bulkhead and From Rear Bulkhead To Control
Cabinet (Electric Dryer Models Only) ........20
20. Stacked Dryer Ground Connections ..............21
Front Control Ground Connections ...............21
Rear Control Ground Connections .................21
(continued)
Section 6 Adjustments
60. Leveling Legs .................................................65
61. Burner Flame (Gas Models) ...........................66
512261
Section 1
Safety Information
Throughout this manual and on machine decals, you will find precautionary statements (CAUTION,
WARNING and DANGER) followed by specific instructions. These precautions are intended for the personal
safety of the operator, user, servicer, and those maintaining the machine.
a DANGER
Danger indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
a WARNING
Warning indicates a hazardous situation that, if not avoided, could cause severe personal injury or death.
a CAUTION
Caution indicates a hazardous situation that, if not avoided, may cause minor or moderate personal injury or property
damage.
Additional precautionary statements (IMPORTANT and NOTE) are followed by specific instructions.
IMPORTANT
The word IMPORTANT is used to inform the reader of specific procedures where minor machine damage will
occur if the procedure is not followed.
NOTE
The word NOTE is used to communicate installation, operation, maintenance or servicing information that is
important but not hazard related.
In the interest of safety, some general precautions relating to the operation of this machine follow.
WARNING
Failure to install, maintain, and/or operate this machine according to the manufacturers
instructions may result in conditions which can produce serious injury, death and/or property
damage.
Do not repair or replace any part of the machine or attempt any servicing unless specifically
recommended or published in this Service Manual and that you understand and have the
skills to carry out.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded and to reduce the risk of fire,
electric shock, serious injury, or death.
W284
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
Repairs that are made to your products by unqualified persons can result in hazards due to
improper assembly or adjustments subjecting you or the inexperienced person making such
repairs to the risk of serious injury, electrical shock or death.
W007
WARNING
If you or an unqualified person perform service on your machine, you must assume the
responsibility for any personal injury or property damage which may result. The manufacturer
will not be responsible for any injury or property damage arising from improper service and/or
service procedures.
W286
NOTE: The WARNINGS and IMPORTANT INSTRUCTIONS appearing in this manual are not meant to
cover all possible conditions and situations that may occur. Common sense, caution and care must be
exercised when installing, maintaining or operating the machine.
Always contact your dealer, distributor, service agent or the manufacturer about any problems or conditions you do
not understand.
512261
Section 2
Introduction
Customer Service
If literature or replacement parts are required, contact
the source from whom the machine was purchased or
contact Alliance Laundry Systems at (920) 748-3950
for the name and address of the nearest authorized
parts distributor.
For technical assistance, call (920) 748-3121.
Nameplate Location
When calling or writing about your product, be sure to
mention model and serial numbers. Model and serial
numbers are located on nameplate(s) as shown.
Nameplate
D412PE1A
512261
Section 2 Introduction
Model Identification
Information in this manual is applicable to these dryers:
FES17A*F
FES17A*F1500
FEU17A*F
FEZ17A*F
FGS17A*F
FGU17A*F
FGZ17A*F
KES17A*F
KES17A*F1500
KGS17A*F
Q - Bisque
LES17A*F
LES17A*F1500
LES37A*F
LGS17A*F
LGS37A*F
W - White
512261
Section 2 Introduction
Cylinder
Lint
Filter
Heater
Duct
Blower
Fan
DRY1819S
The dryer uses heated air to dry loads of laundry. When the motor is started, the exhaust fan pulls room temperature
air in through louvers at the rear of the dryer and over the heat source (burner flame for gas and heating element for
electric). The heated air moves through the heater duct and into the cylinder, where it circulates through the wet load.
The air then passes through the lint filter, air duct, and exhaust fan, where it is vented to the outdoors.
512261
Section 2 Introduction
Notes
512261
Section 3
Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
TO CORRECT
Electrical power off, fuse blown, or power cord not Check laundry room for blown or loose fuse(s), or open
plugged in.
circuit breaker(s). The dryer itself does not have an
electrical fuse.
Loading door not closed.
Inoperative door switch.
Timer improperly set.
Inoperative timer.
Motor starting functions inoperative.
Does not start, or motor just hums.
Motor is dead, will not run.
Motor overload protector has cycled.
Motor centrifugal switch sticky or plugged with
lint.
Bind in motor bearing.
Loose motor wire harness connection block.
Broken, loose, or incorrect wiring.
Power cord is miswired.
512261
Section 3 Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
2. DRYER STOPS IN CYCLE; QUITS AFTER THE FIRST FEW LOADS; HAS A BURNING SMELL;
CYCLES ON MOTOR THERMAL PROTECTOR
POSSIBLE CAUSE
TO CORRECT
Incorrect Voltage.
10
512261
Section 3 Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
TO CORRECT
Tighten pulley.
Install belt. Refer to Figure 25.
Replace belt.
Check cylinder for binding and out of round condition.
Dryer is overloaded.
Wrong motor.
Wrong belt used on dryer.
TO CORRECT
512261
11
Section 3 Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
TO CORRECT
6. DRYER HEATING ASSEMBLY DOES NOT HEAT OR BURNER DOES NOT IGNITE
POSSIBLE CAUSE
TO CORRECT
Reconnect as required.
Clean out gas orifice.
Test thermostat and replace if inoperative.
Test timer and replace if inoperative.
Refer to wiring diagram.
512261
Section 3 Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
7. IGNITER DOES NOT GLOW (Gas Supply Sufficient) GAS DRYER MODELS
POSSIBLE CAUSE
TO CORRECT
TO CORRECT
Cracked igniter.
Inoperative or intermittent gas valve coils.
9. IGNITER GLOWS BUT BURNER DOES NOT IGNITE GAS DRYER MODELS
POSSIBLE CAUSE
TO CORRECT
Replace sensor.
Replace coils. Refer to Paragraph 68.
Check gas supply and pressure.
512261
13
Section 3 Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
TO CORRECT
TO CORRECT
14
512261
Section 3 Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
TO CORRECT
TO CORRECT
Refer to Paragraph 6.
512261
15
Section 3 Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
TO CORRECT
16
512261
Section 3 Troubleshooting
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
TO CORRECT
TO CORRECT
TO CORRECT
512261
17
Section 3 Troubleshooting
Notes
18
512261
Section 4
Grounding
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
18. GROUND WIRES FROM POWER CORD TO REAR BULKHEAD AND FROM REAR BULKHEAD
TO CONTROL CABINET
Check Wall Receptacle Polarity (Gas Dryer Models Only)
Refer to Figure 1.
Ground
Wires
Ground
L1
0
V.A.C.
11512
V.A.C.
11512
V.A.C.
Neutral
Side
Dryer
Power Cord
D354SE3A
Figure 1
512261
19
Section 4 Grounding
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
19. GROUND WIRE FROM TERMINAL BLOCK TO REAR BULKHEAD AND FROM REAR
BULKHEAD TO CONTROL CABINET
(Electric Dryer Models Only)
Refer to Figure 2.
Ground
Wires
H006GE3A
Figure 2
20
512261
Section 4 Grounding
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
512261
21
Section 4 Grounding
1
2
4
3
SWD4G
SWD4G
Stacked Dryer
1
3
DRY6G
DRY6G
3
DRY7G
DRY7G
512261
Section 5
Service Procedures
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
7/16
Screw
Notches
Control
Panel
Service
Door
DRY1818S
Figure 4
512261
23
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
24
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
512261
25
Screws
Top
Cover
Left
End Cap
Screw
Fabric Selector
Switch
Signal
Screw
Timer
Fabric
Selector
Switch Knob
Assembly
Screw
Signal
Switch
Knob
Assembly
Extend
Tumble
Rocker
Switch
Right
End Cap
Screw
Timer Knob
Assembly
Control Hood
Rear Panel
Graphic
Panel
Support
Control Panel
DRY161P
Cabinet
Top
Figure 5
GRAPHIC PANEL, CONTROL HOOD AND CONTROLS REAR CONTROL DRYERS
26
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
512261
27
Top
Panel
Bolt
Screw
Control
Cabinet
Rear
Left
Control
Cabinet
Screw
Nut
Screw
Expansion
Clip
Graphic
Overlay
Right
Control
Cabinet
Fabric
Selector
Switch
Timer
Screw
Signal
Switch
Fabric
Selector
Switch
Knob
Assembly
Control
Panel
Assembly
Signal
Switch
Knob
Assembly
Extend
Tumble
Rocker
Switch
Screw
Timer
Knob
Assembly
Control
Cabinet
Bottom
DRY1828S
Figure 6
CONTROL PANEL AND CONTROLS FRONT CONTROL DRYERS
28
512261
Screw
Rear
Control
Cabinet
Left
Control
Cabinet
Screw
Screw
Nut
Expansion
Clip
Right
Control
Cabinet
Control
Panel
Assembly
Timer
Graphic
Overlay
Fabric
Selector
Switch
Timer
Screw
Timer
Knob
Assembly
Control
Cabinet
Bottom
Fabric Selector
Switch Knob
Assembly
Screw
Expansion
Clip
Timer
Knob
Assembly
DRY1829S
Figure 7
CONTROL PANEL AND CONTROLS STACKED DRYERS
512261
29
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Access
Panel
Front Panel
Attaching
Screws
Panel
Attaching
Screws
D302SE3B
Figure 8
DRY1817S
Figure 9
30
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Cabinet Top
Hold-Down Screws
Cabinet
Top
Rear
Hold-Down
Brackets
D339S
D394S
Figure 11
Figure 10
512261
31
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Lint Filter
Attaching
Screw
Hinge
Attaching
Screws
Loading Door
Attaching
Screws
Lint
Filter
Front
Bulkhead
D306S
Figure 12
32
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Door
Seal
Door
Strike
Outer Door
Panel
Screw
Wedge
Door
Pull
Screw
Inner Door Panel
and Seal Assembly
Screw
Door Hinge
Front
Panel
Screws
Screw
D343P
Figure 13
512261
33
A
D312S
D377S
D311S
A
D314S
D315S
D313S
D382S
D316S
D378S
Figure 14
34
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Door Seal
Door Seal
Tab
Inner Door
Panel Slot
Bottom Of Door
Inner Door
Panel
D335S
Figure 15
512261
35
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Door
Switch
Tabs
H183SE1A
Figure 16
36
512261
Screw
Hold-Down
Clip
Door
Switch
Front
Panel
Seal
Locator
Sticker
Door
Catch
Nameplate
Front
Panel
Hinge
Hole
Plugs
Screw
Screw
Locator
Lower
Access
Panel
Screw
SWD648P
Figure 17
512261
37
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Lint Filter
Attaching
Screw
Door
Hinges
Door
Attaching
Screws
38
D306S
Figure 18
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Screw
Heater
Box
Attaching
Screws
Burner
Housing
Sensor
Attaching
Screw
Burner
Tube
Screw
Igniter
Wires
Disconnect
Block
Lead-In
Pipe
Sensor
Tab
Sensor
Terminals
Shut-Off
Valve
(Shown in closed position)
Secondary
Coil
Holding
And
Booster
Coil
Gas
Valve
Nipple
Union
Nut
D241SE3G
Figure 19
512261
39
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Igniter and
Bracket
White
Ceramic
Portion
Burner
Tube
Tab
Burner
Tube
Air
Shutter
D242SE3A
Figure 20
40
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
ELECTRIC MODELS
GAS MODELS
Heater
Assembly
Heater Wire
Connections
Limit
Thermostat
Burner Tube
Limit
Thermostat
Burner
Tube
Screw
Base
Thermal
Fuse
Screw
Screw
Burner
Housing
D244SE3B
D243SE3A
Figure 21
512261
41
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Screw
Front
Bulkhead
47. THERMOSTAT
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 8.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 17.
c. Disconnect wires and remove thermostat
attaching screws. Refer to Figure 22.
Seal
Attaching
Screws
Wire
Harness
Lint
Filter
Front
Air Duct
D307SE1D
Figure 23
Ground
Wire
Ground
Screw
Thermostat
D400SE1F
Figure 22
42
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
WARNING
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
Ground
Wire
Motor
Mount
Attaching
Screws
Thermostat
D400SE1E
Figure 24
512261
43
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
CORRECT WAY
Belt
Idler
Pulley
INCORRECT WAY
Exhaust
Duct
Idler
Pulley
Belt
Idler
Lever
D247SE1A
Idler
Lever
Exhaust
Duct
D248SE1A
Figure 25
WARNING
Motor
Switch
Retaining
Ring
1
5
W005
2 6
Motor
Clamp
44
Idler
Pulley
Idler
Spring
Motor
Pulley
D296SE3B
Figure 26
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
n. Motor.
(1) Disengage motor wire harness terminal
block from the motor by pressing in on the
movable locking tabs (located on each side
of the terminal block) and pulling away
from motor. Refer to Figure 28.
IMPORTANT: To avoid an open circuit, DO NOT
pull on the terminal block wires when removing
blocks from motor as this could damage the wires or
terminal crimping.
Motor
Wire Harness
Connection Block
Locking
Tabs
D250SE3A
Figure 28
Blower Housing
Attaching Screws
D249SE3B
Figure 27
512261
45
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Terminal
Locking
Tab
Connection
Block
D251SE3A
Figure 29
46
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Cabinet Top
Hold-down
Screw
Front
Bulkhead
Bulkhead
Attaching
Screws
Bulkhead
Attaching
Screws
Slot
WARNING
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
Slot
Cylinder
Glide
D394S
Air
Duct
Cabinet
Attaching
Screw
Cabinet
Attaching
Screw
Figure 30
Screws
Cylinder
Glide Bracket
D256SE3C
Figure 31
47
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Long Flap
Short Flap
(Must be glued
to bulkhead)
Seal Stitching
(Must face towards
center of dryer)
Bulkhead
D257SE3A
Figure 32
48
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Front
Bulkhead
WARNING
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
Lint
Filter
W005
D307SE1C
Figure 33
512261
49
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
D414S
Rear
Rib
Screw
Figure 34
WARNING
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
50
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
51
Rear
Seal
Outlet
Cover
Rear
Bulkhead
Attaching
Screws
Rear
Bulkhead
Attaching
Screws
Cylinder
Roller
Cylinder
Roller
Heater
Box
Exhaust
Duct
Screw
D405S
Figure 35
52
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Rear
Bulkhead
Locknut
WARNING
Roller
Bracket
Shaft
Washers
W005
Screw
Retainer
Ring
Flanged Surface
of Roller Bearing
(Must face toward front of dryer)
D260SE3B
Figure 36
53
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
54
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
j. Electric Models:
(1) Remove two screws holding element and
plate to heater box, then pull element down
and away from heater box. Refer to
Figure 21.
(2) Remove all wires from terminal block.
(Refer to appropriate wiring diagram when
rewiring terminal block.)
Rear
Bulkhead
Heater
Duct
Attaching
Screws
Heater
Duct
Attaching
Screws
Heater
Duct
D261SE3B
Figure 37
512261
55
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Terminal
Block
Terminal Block
Attaching
Screw
D406S
Figure 38
56
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Ground
Wires
Ground
L1
0
V.A.C.
11512
V.A.C.
11512
V.A.C.
Neutral
Side
Dryer
Power Cord
D354SE3A
Figure 39
512261
57
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
58. CABINET
a. Side Panels:
(1) While supporting the access panel, remove
two screws from bottom edge of access
panel. Refer to Figure 8.
(2) Gently lower the access panel to disengage
locators from bottom edge of front panel.
Refer to Figure 17.
(3) Remove two screws holding bottom tabs on
front panel to dryer side panels. Refer to
Figure 9. Swing bottom of front panel away
from dryer far enough to disengage holddown clips and locators from cabinet top.
(4) Disconnect wires from door switch. Refer
to Figure 16.
NOTE: Refer to wiring diagram when rewiring
control panel components.
(5) Remove front panel.
(6) Disengage belt from motor and idler
pulleys. Refer to Figure 25.
NOTE: When reinstalling belt, be sure belt is
properly installed on motor and idler pulleys and is
on the correct side of the idler lever. Refer to
Figure 25. Belt must be positioned around center
section of cylinder approximately three inches
ahead of rear rib on cylinder with the ribbed
surface of the belt against the cylinder. Refer to
Figure 34. After installing belt, manually rotate
cylinder counterclockwise to check that belt is
properly aligned.
(7) Models with Cylinder Light Disconnect
wires from light receptacle terminals.
(8) Models with Cylinder Light Disconnect
wire clip from front bulkhead.
(9) Remove four screws holding front
bulkhead to dryer. Refer to Figure 35.
Remove front bulkhead.
NOTE: Air duct can remain attached to front
bulkhead.
58
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
To reduce the risk of serious injury or
death by carbon monoxide and other
gases in gas dryers, carefully read and
follow all instructions given in this section.
W005
512261
59
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
512261
Screw
Screw
Screws
Screws
DRY1820S
Figure 40
512261
61
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
59. BASE
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 8.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 17.
c. Remove two screws holding bottom tabs on
front panel to dryer side panels. Refer to
Figure 17. Swing bottom of front panel away
from dryer far enough to disengage hold-down
clips and locators from cabinet top.
d. Disconnect wires from door switch. Refer to
Figure 16.
NOTE: Refer to wiring diagram when rewiring
switch.
WARNING
To reduce the risk of serious injury or
death by carbon monoxide and other
gases in gas dryers, carefully read and
follow all instructions given in this section.
W005
e. Gas Models:
(1) Disconnect igniter wires at disconnect
blocks, sensor wires from sensor terminals
and wires from gas valve coils at the quick
disconnect blocks. Refer to Figure 19.
(2) Close main gas shut-off valve. Refer to
Figure 19.
(3) Disconnect gas line to dryer.
(4) Remove three screws holding gas valve
bracket to base and remove valve with
attached lead-in pipe. Refer to Figure 21.
(5) Remove screw holding burner tube in place
from right side of burner housing. Refer to
Figure 21.
(6) Gently move burner tube toward rear of
dryer to disengage tab from slot on left side
of burner housing. Refer to Figure 19.
62
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
512261
63
Notes
64
512261
Section 6
Adjustments
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
Dryer
Base
Leveling
Leg
D351S
Figure 41
512261
65
Section 6 Adjustments
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
To reduce the risk of fire or serious injury,
the access panel must be in place during
normal operation.
W262
Air Shutter
Lockscrew
Shut-Off Valve
Handle
(Shown in open position)
Air
Shutter
D265SE3A
Figure 42
66
512261
Section 7
Test Procedures
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
512261
67
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
H
L3
L3
No. 270
No. 270
H
L2
L2
H
L2
L2
P/B
L1 P/B
P/B
M
L1 P/B
L2
L2
RSPC
MODEL 275BEF
L1
TM
MOD
60-1
XXX VAC
L1
RSPC
MODEL 275BEF
TM
MOD
60-1
NGSTON
KI
Timer Motor
Wires
NGSTON
KI
XXX VAC
3 WATT
3 WATT
Timer Motor
Wires
DRY1827S
DRY1826S
GAS MODELS
ELECTRIC MODELS
Figure 43
Delicate
X
X
Perm. Press
X
Regular
X
X indicates closed
FABRIC SELECTOR SWITCH 3 Position
L1-2
L1-3
L1-1
No Heat
Delicate
X
X
Perm. Press/Regular
X
X indicates closed
68
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Motor
Switch
Motor
Disconnect
Block
Motor and
Exhaust
Assembly
5
4
2 6
Drive
Motor
D326SE3A
Figure 44
512261
69
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
c. Motor Switch (Refer to SECTION 8 for Internal Wiring of the Dryer Motor Switch.)
WARNING
Disconnect electric power to dryer before performing any of the following
steps or when replacing inoperative motor switch.
W290
NO
YES
B. Manually depress actuator.
Continuity broken between switch
terminal 5 and terminal 3 (black or
copper wire).
NO
Inoperative start
switch. Replace switch.
Refer to Section 5.
YES
Run Terminals
Note: Reconnect
terminal 5 wire (yellow
or copper) to motor
switch before testing run
terminals.
NO
NO
YES
E. Continuity broken between switch
terminal 1 and switch terminal 2.
Inoperative start
switch. Replace switch.
Refer to Section 5.
NO
YES
F. Manually depress actuator.
Continuity exists between switch
terminal 1 and switch terminal 2.
NO
Inoperative start
switch. Replace switch.
Refer to Section 5.
YES
Motor switch checks O.K.
70
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
d. Motor Windings (Refer to SECTION 8 for Internal Wiring of the Dryer Motor Switch.)
WARNING
Disconnect electric power to dryer before performing any of the following
steps or when replacing inoperative motor switch.
W290
Start Winding
NO
YES
Run Main Winding
NO
YES
Protector
I.
NO
Inoperative protector.
Replace motor.
Refer to Paragraph 49.
YES
All motor windings check O.K.
512261
71
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Mounting
Tab
Thermal
Overload
Protector
Motor
Switch
D029KE3A
Figure 45
72
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
f. Test motor switch by following the step-bystep procedures included in Paragraph 64.
g. Before reinstalling the motor assembly, apply
power (120 VAC) directly to motor terminals 4
and 5. Then start and run the motor at least 6
times, making sure the motor and switch are
operating properly.
NOTE: The dryer manufacturer and parts
suppliers are not liable for improper switch
installation.
Thermal
Overload
Protector
Plastic
Clip
Top Of
Motor
Switch
Motor
Switch
D359SE3A
Figure 46
512261
73
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
4
Secondary
Coil
5
1
Holding Coil
and
Booster Coil
(Split Coil Valve)
Sensor
HOLDING
COIL
BOOSTER
COIL
Igniter
D268SE3A
D267SE3B
Figure 47
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
To reduce the risk of fire, explosion and
electric shock, close the valve in the gas
supply line to the gas dryer and disconnect
the electrical power unless gas or power
supplies are required to perform test
procedure.
W263
Secondary
Coil
4 5
2
1 - 3
3
Holding
And Booster
Coil
D270SE3A
Figure 48
512261
75
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Attaching
Screw
Igniter and
Bracket
White
Ceramic
Portion
Figure 49
76
512261
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
Element
Color
KW
Code
Voltage/Hz.
Red
White
4.75
Orange
5.35
Purple
4.25
Resistance Reading
512261
77
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
78
512261
Section 8
Internal Wiring of Dryer Motor Switch
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
MAIN
START
BLACK/COPPER
CUSTOMER CIRCUIT
OVERLOAD
PROTECTOR
PUSH TO
START
YELLOW/COPPER
ORANGE/COPPER
BLUE/BROWN
LINE
2 6
4 3
S
R
R
4 3
R.S.P.C.
Motor Switch
Attaching Screws
G
D329SE3D
Figure 50
512261
79