You are on page 1of 20

Antenna Swap Checklist for Bharti Project V1.

Check Date

7/5/2014
10733
28.69822
77.14116

Site ID
Latitude
Longitude

Checked by
Site Name
Ports of Antenna to Swap
Type of Antenna to Swap
Detailed Checklist

Sector 1

2G Pre(900)

2G Post(900)

2G Pre(1800)

2G Post(1800)

Electrical-Tilt

NA

NA

Mechanical-Tilt

NA

NA

Antenna Height

25 M

25 M

NA

NA

350

350

NA

NA

Antenna Azimuth
New Added Diplexer

NA

NA

New Added Jumper Length

New Added Feeder Length

VSWR Alarm
Sector 2
Electrical-Tilt

2G Pre

2G Post

2G Pre

2G Post

NA

NA

Mechanical-Tilt

NA

NA

Antenna Height

25 M

25 M

NA

NA

Antenna Azimuth

100

100

NA

NA

New Added Diplexer

NA

NA

New Added Jumper Length

New Added Feeder Length

VSWR Alarm
Sector 3
Electrical-Tilt

2G Pre

2G Post

2G Pre

2G Post

Mechanical-Tilt

Antenna Height

25 M

25 M

22 M

22 M

240

240

230

230

Antenna Azimuth
New Added Diplexer

NA

NA

New Added Jumper Length

New Added Feeder Length

VSWR Alarm
Sl No

Items

Check the Antenna Height

Check the Azimuth

Check the Antenna tilt (Mechanical)

Check the Antenna tilt (Electrical)

Check the Antenna type

6
7
8

Check Cable Swap(Partial/Full)


Check the alarm - all alarms cleared both Pre and Post
Whether voice call mobile handset to mobile handset or not in Cell 1

9
10
11
12
13
Comments

Whether voice call mobile handset to mobile handset or not in Cell 2


Whether voice call mobile handset to mobile handset or not in Cell 3
Check for loose connectors at BTS & antenna end for both feeder & Jumper cables
Check for weather proofing for all connectorisation
Check for sharp bends for feeder cable

Kuldeep Hudda
e_DLI10733
6 Ports

6 Ports

6 Ports

G900+U2100

G900+U2100

G900+U2100

3G Pre

3G Post

25 M
25 M
350
350

U2100+L2300
m

m
No

No

3G Pre

3G Post

25 M

25 M

100

100

U2100+L2300
m
m
No

No

3G Pre

3G Post

25 M
25 M
240
240

U2100+L2300
m
m
No

No
YES/NO
YES
YES
YES
YES
YES
YES(NO
SWAPPING OF
CABLES)
YES
YES

mper cables

YES
YES
YES
YES
YES

BCCH/BSIC Plot
Pre

RxQual_Sub Plot
Pre

RxLev Plot
Pre

Hadover Plot
Pre
HO SUCCESS Plot

RxQual Comparison Summary


Item
RXQual
RxQual %

[0, 2)
552
62.73%

[2, 5)
191
21.70%

Pre
[5, 7)
137
15.57%
RxLev Comparison Summary

Item

[-65, 0)

[-75, -65)

Pre
[-85, -75)

[-95, -85)

[-120, -95)

RxLev
RxLev %

249
28.04%

379
42.68%

228
25.68%

24
2.70%

8
0.00%

Handover Comparison Summary


Item
Handover

Attempt
19

Pre
Success
19

Success Rate
100%
Remark

we Can not cover the Gama sector due to d

Pre
Rx Quality
Rx Level

post
880
888

748
748

BCCH/BSIC Plot
Post

RxQual_Sub Plot
Post

RxLev Plot
Post

Hadover Plot
Post

RxQual Comparison Summary


[0, 2)
513
68.58%

[2, 5)
157
20.99%

Post
[5, 7)
78
10.43%

[-75, -65)

Post
[-85, -75)

RxLev Comparison Summary


[-65, 0)

[-95, -85)

[-120, -95)

179
23.93%

256
34.22%

286
38.24%

27
3.61%

0
0.00%

Handover Comparison Summary


Attempt
17
Remark

ot cover the Gama sector due to dense area

Post
Success
17

Success Rate
100%

9953054892

HO Attempt Plot PRE

HO Attempt Plo
POST

HO Attempt Plo
POST