Overview

Features

Module Showcase

Connection Details

Installing PC Software and drivers


Installing drivers . . . . . . . . . . . . . . . . . . . . . . . .

6
6

Configuring using PC Software

FAQ

12

Overview
e-SECURE is an alert system which can monitor the security devices
connected to the LAN network, ensure its working status. It can generate alert messages when devices connected to the LAN is not working or
not connected to the network. User configuration tool provides different
customization options for adding or deleting devices for monitoring. Alert
messages can be sent to any phone inside the country, and provides option
for adding or deleting phone numbers using the configuration tool.
e-SECURE module supports maximum of 40 IP devices conected to
the LAN network and 10 phone numbers for sending alert messages. eSECURE Configuration tool provides an easy way to update, add or delete
the device list and phone number list.

Features
Power consumption less than 6W
DualBand GSM Module with high gain Antenna
Easy connectivity with RJ-45 connector
Status LED indication
User friendly configuration software
With secured Enclosure
SIM switcher tray
Configuration tool supports Windows 8/7/XP
Maximum of 40 devices supported
Maximum of 10 Phone numbers for sending messages

Module Showcase

Figure 1: Front View

Connection Details

Figure 2: Front Panel

LED indication
Green - ON
Red - OFF
Green - OFF
Red - ON
Green - ON
Red - ON

status
Status OK
One or more IP down
Configuration Mode
4

USER MANUAL

e-SECURE

Figure 3: Connection Diagram


Insert SIM Card inside the slot provided before power on.
Connect Power adaptor to the DC Power Jack. Make sure the power
adaptor is 12 Volt providing minimum 1 Ampere current.
Connect LAN connector to the Router through standard RJ-45 connector.
Connect USB A to B cable for calibration
Connect High gain antenna to the module in low range areas.

www.elementzonline.com

Installing PC Software and


drivers
Installing drivers
Extract the software provided in the support CD to any preferred location in your computer.Select the driver for 32 bit/64 bit and install it or
show the path.
On Windows 7/8/8.1/XP
Double click on CP210x_VCP_Win_XP_S2K3_Vista_7.exe
Choose the installation path.
Click next and complete the installation by clicking on Finish button.
You can check that the drivers have been installed by opening the
Windows Device Manager (in the Hardware tab of System control panel).
Look for "Silicon Laboratories" in the Ports section.

Configuring using PC
Software
Using the PC software one can create a new list of IP addresses to be
monitored and Phone numbers to which the alerts are to be send.

Remarks

Insert configuration jumper properly before using the configuration utility.

Configuration jumper configuration can be set by shorting A5 and A4


pins on board, after releasing jumper connected to A4 and A3 pins.

Connecting serial port using Configuration Utility

1. Connect the USB Cable provided to the e_SECURE Module.


Make sure driver is installed properly, if using for the first time.
2. Open the configuration utility by clicking on the CamSec.exe
icon.
3. Press the Refresh ports button.
4. Select the correct serial port from the dropdown menu.
5. Open the serial port by clicking the Open port button.
7

USER MANUAL

e-SECURE

Figure 4: Serial configuration


If connection is proper the console will be displayed with content
Port opened successfully. Refer the following screenshots.

Figure 5: Serial configuration


Configure IP list to be monitored
1. Click the Change IP button.
2. To create newlist click on the Create new list button.
www.elementzonline.com

USER MANUAL

e-SECURE

3. Enter IP address in the Enter IP field and enter Camera nickname in Enter Name field.
4. Click Add IP.
5. To continue adding IP Addresses repeat the steps used.
6. Finally Upload to device should be pressed to upload the list
to the device.

Figure 6: IP Configuration

Figure 7: IP Configuration
www.elementzonline.com

USER MANUAL

e-SECURE

Add phone numbers to send alert

1. Click the Change Phone numbers button.


2. To create newlist click on the Create new list button.
3. Enter Phone number in the Enter phone number field.
4. Click Add Number.
5. To continue adding more Numbers repeat the steps used.
6. Finally Upload to device should be pressed to upload the list
to the device.

Figure 8: Phone number configuration


www.elementzonline.com

10

USER MANUAL

e-SECURE

Figure 9: Phone number configuration

Remarks

After configuration make sure that the A4 and A3 pins are


shorted for normal working of the module.

www.elementzonline.com

11

FAQ
What is the minimum specification of input power for the working
of the module?
DC Adaptor capable of providing 9 Volt supply or more. 12
Volt/ 1 Ampere is recommended as the standard supply source for
reliable operation.
Which operation systems are supported by the configuration software?
All new windows versions newer than Windows XP are supported, which includes Windows Vista/7/8/8.1. For other OS, user
should contact the support desk by mailing at info@elementzonline.com.
Why configuration mode cannot be activated through the Configuration software?
Before running the configuration software, make sure the configuration jumper is properly inserted in the hardware.
Why no alert messages are comming from the e-SECURE module?
Make sure GSM Antenna and SIM is inserted. Also check whether
the configuration jumper is properly inserted for working as normal
mode.
How to check whether the GSM Modem and SIM Card are working?
Make a call to the SIM number in the GSM Modem. If you
are getting the ring sound at the caller end, then GSM Modem is
working. If not reachable, please reapply power.