You are on page 1of 2

Project:

Cardenillo Paute
Reference Number: BODL Bomba drenaje XFOs

Company name:
Created by:
Phone:
Fax:
Date:

Poyry (Peru) SAC


RAU
06.03.2013

Client:
Client Number:
Contact:

CELEC
-

NB 65-125/137 50 Hz
Input

Sizing result

Select Application
Overview mode

Yes
Industrial
applications

Input overview:
Select Type of Installation
Select subapplication
Select subapplication
Dimensioning flow
Total head
Pumped liquid
Min. liquid temperature
Liquid temperature during operation
Installation type
Variable speed
Select type of hydraulic
Preferred number of poles
Max. hits per product group
Max. hits total
Evaluation criterion
Energy price
Increase of energy price
Pump operating time
Calculation period
Frequency
Phase
Min. power limit for SD start
Voltage
Immersible
Immersible horizontal
Submersible (Wastewater)
Inline Multistage
Inline single stage
End-suction long-coupled
End-suction close coupled
End-suction close coupled vertical
singlestage
End-suction close coupled horizontal
multistage
End-suction singlestage pump with
semi-open impeller MTB
Encapsulated
Horizontal splitcase

Water Treatment
Intake
Water-based
100 m/h
20 m
Water
10 C
20 C
Inlet pressure
Uncontrolled
Single
2
2
8
Preference index
0.15 /kWh
6%
1113.25 h/a
5 years
50 Hz
1 or 3
5.5 kW
1 x 230 or 3 x 400
V
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Type
NB 65-125/137
Quantity 1
Motor
7.5 kW
Flow
Head
Power P1
Power P2
Eta pump
Eta motor
Eta pump+motor
Eta total
Energy consumption
CO2 emission
Price
Price + energy costs

m/h ( +1%)
m ( +1%)
kW
kW
%
%
% =Eta pump * Eta
motor
73.9 % =Eta relative to the
duty point
8333 kWh/Year
4750 kg/Year
On request
On request /5Years

H
[m]

NB 65-125/137, 3*400 V, 50Hz

26

Q = 101 m/h
H = 20.2 m
Pumped liquid = Water
Liquid temperature = 20 C
Density = 998.2 kg/m

24

eta
[%]

22
20
18
16
14
12
10

100

80

60

40

Eta pump = 82 %
Eta pump+motor = 73.9 %

0
0

Yes

101
20.2
7.48
6.74
82.0
90.1
73.9

20

40

60

80

100

120

20
0

Q [m/h]

P
[kW]

NPSH
[m]
P1

Yes
P2

Yes
Yes

Load Profile
Flow
Head
P1
Eta total
Time
Energy consumption
Quantity

1
100
101
7.48
73.9
1113
8333
1

Printed from Grundfos CAPS [2013.02.032]

%
%
kW
%
h/Year
kWh/Year

P1 = 7.49 kW
P2 = 6.75 kW
NPSH = 3.3 m

1/2

Company name:
Created by:
Phone:
Fax:
Date:

Poyry (Peru) SAC


RAU
06.03.2013

Project:
Cardenillo Paute
Reference Number: BODL Bomba drenaje XFOs

Client:
Client Number:
Contact:

CELEC
-

Installation and Input

Sizing Results
Type
NB 65-125/137
Quantity * Motor 1 * 7.5 kW
Flow
101
H total
20.2
Power P1
7.48
Power P2
6.74
Eta pump
82.0
Eta motor
90.1
Eta pump+motor
73.9
Flow total
111926

Dimensioning flow: 100 m/h

Energy consumption
Price
Price + energy costs

Pump Curve

m/h ( +1%)
m ( +1%)
kW
kW
%
%
% =Eta pump * Eta motor
m/year
mm
mm
8333 kWh/Year
On request
On request /5Years

Dimensional Drawing

H
[m]

NB 65-125/137, 3*400 V, 50Hz

eta
[%]

Q = 101 m/h
H = 20.2 m
Pumped liquid = Water
Liquid temperature = 20 C
Density = 998.2 kg/m

26
24
22
20

160

180

18

60

40
Eta pump = 82 %
Eta pump+motor = 73.9 %
0

20

40

60

80

100

120

95

212
280
117

12

20
0

Q [m/h]

P
[kW]

NPSH
[m]

135
135

379

100

80

159
159

100

203
203

10

212

12

8 x 19

65

14

100

65

146

16

P1
P2
5

Printed from Grundfos CAPS [2013.02.032]

4 x 19

100

80

P1 = 7.49 kW
P2 = 6.75 kW
NPSH = 3.3 m

95
125

313

300

2/2

You might also like