EQUIPMENT: SRAL XD
TITLE: SRAL XD - Single Board 2
VERSION: 2
REVISION: 0
STATUS: Complete
DATE: 7/31/2007
Issued by
CMO GS NI SE
SS. Padana Superiore Km 158
20060 Cassina De Pecchi (MI)
The information in this document is subject to change without notice and describes only the product defined in the introduction of
this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the
agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form
or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by
professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks
welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned
hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall
be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia
Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free
of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues
which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS
NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED
TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES,SUCH AS BUT NOT LIMITED TO
LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM
THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights
according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a
registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for
identification purposes only.
Copyright © Nokia Siemens Networks 2007. All rights reserved.
EXTERNAL OPERATION
INTERNAL OPERATION
• For the internal operations wear shoes with rubber soles and heels, protective clothing including a long-
sleeved shirt and rubber gloves.
• In order avoid any demage while handling the modules, the user should wear an antistatic elastic
bracelet, grounded by means a spiral cord.
• Before supplying the equipment, it is necessary to complete the wiring of the connections to the
protection ground, the insertion of all the units and/or modules provided fot the requested configuration
and also the connection of all the necessary connectors.
• The connection to the protection ground must not be removed or damaged.
• Handle carefully the optical fiber.
• A broken optical fiber can cause damages to eyes and skin, do not point to the eyes a broken fiber or an
incomplete one or an optical connector not covered.
• If the optical source is not surely switched off, do not directly or for reflection stare (particulary using
lenses or by means af a microscope) at a broken fiber or at an incomplete one or at an optical connector
not covered and do not execute or interrupt an optical connection.
• Do not connect a fiber to an optical output without checking that the fiber terminal is ended and do not
supply the optical tributary out of the sub-rack and do not change the factory settings and adjustments.
Non-observance of the safety instructions can result in personal injury or in property demage.
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This
documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and
no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia
Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are
given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement
between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens
Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR
ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL OR ANY LOSSES,SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of
Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
INSTALLATION INFORMATION
• Frequency Band = 7 - 8 - 13 - 15 - 18
23 - 26 - 28 - 32 - 38 GHz
• Capacity = up to 8 or 16 x 2 Mb/s
• Configurations = 1+0
1+1 Hot-Standby
INDEX
4. 1+1 FRAME NOT INTEGRATED SYSTEM (7 to 38 GHz) (IMC 0358BEDG - Ed. 02)
Revisions
Document
01 02 03 04 05 06 07 08 09 10
IMC 6011BEDG ¯ ¯
IMC 0354BEDG ¯ ¯
IMC 0355BEDG ¯ ¯
IMC 0356BEDG ¯ ¯
IMC 0358BEDG ¯ ¯
IMC 0254BEDG ¯ ¯ ¯ ¯ ¯ ¯ ¯
IMC 0255BEDG ¯ ¯ ¯ ¯ ¯ ¯ ¯
IMC 0256BEDG ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯
IMC 0257BEDG ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯
IMC 0258BEDG ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯
IMC 0359BEDG ¯ ¯
IMC 0360BEDG ¯ ¯
IMC 0260BEDG ¯ ¯ ¯ ¯ ¯ ¯
IMC 0361BEDG ¯ ¯
IMC 0262BEDG ¯ ¯ ¯ ¯ ¯ ¯
INTEGRATED ANTENNA
for SRA L
(See Sheet 3)
OUTDOOR ASSEMBLY
(See IMC 0256BEDG)
SINGLE-BOARD
INDOOR ASSEMBLY
(See IMC 0359BEDG)
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
LCT 1-8
ALMs USER Q-LAN V-LAN
T M C
ODU CABLE PS
O C E N /
D B C S / M
U L H T W J
+ -
INTEGRATED ANTENNA
for SRA L
(See Sheet 3)
OUTDOOR ASSEMBLY
(See IMC 0256BEDG)
SINGLE-BOARD
INDOOR ASSEMBLY
(See IMC 0359BEDG)
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
ALMs USER Q-LAN V-LAN 1-8 9-16
ODU CABLE ODU CABLE T M C
O C O C E N / PS
D B C D B C S / M
U L H U L H T W J
+ -
ANTENNA
DIAMETER (m)
FREQUENCY P/N FEEDER
BAND
FLANGE
(GHz)
0,2 0,3 0,6 0,8 1,2
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ -
02 ¯ ¯ -
03 ¯ ¯ -
04 ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
OUTDOOR ASSEMBLY
(See IMC 0256BEDG)
INTEGRATED ANTENNA
for SRA L
(See Sheet 6)
SINGLE-BOARD
INDOOR ASSEMBLY
(See IMC 0359BEDG)
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
1-8 9-16
ALMs USER Q-LAN V-LAN
T M C
ODU CABLE ODU CABLE
O C O C E N / PS
D B C D B C S / M
U L H U L H T W J
+ -
ODU UP
(See IMC 0256BEDG) MAIN
POLE Ø 75÷115
550 mm (ODU ND/HDe) (a)
450 mm (ODU ND2) (a) or
DOWN
HSBY
ODU SAFETY
HOOK
PROTECTION COVER
O-RING
(a)
PROTECTION COVER
STEP TWIST
POLARIZATION CHANGE
V V
STEP TWIST
H H
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ -
02 ¯ ¯ -
03 ¯ ¯ -
04 ¯ ¯ -
05 ¯ ¯ -
06 ¯ ¯ -
07 ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
INTEGRATED ANTENNA
for SRA L
(See Sheet 8)
FLEXIBLE WAVEGUIDE
(b)
(See IMC 0254BEDG)
OUTDOOR ASSEMBLY
(See IMC 0256BEDG)
VERTICAL 1+0 FRAME
(See Sheets 3÷7)
SINGLE-BOARD
INDOOR ASSEMBLY
(See IMC 0359BEDG)
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
ALMs USER Q-LAN V-LAN LCT 1-8
ODU CABLE T M C
O C E N / PS
D B C S / M
U L H T W J
+ -
FLEXIBLE WAVEGUIDE
(b)
(See IMC 0254BEDG)
OUTDOOR ASSEMBLY
(See IMC 0256BEDG)
SINGLE-BOARD
INDOOR ASSEMBLY
(See IMC 0359BEDG)
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
1-8 9-16
ALMs USER Q-LAN V-LAN
T M C
ODU CABLE ODU CABLE
O C O C E N / PS
D B C D B C S / M
U L H U L H T W J
+ -
Ø75÷115mm POLE
1+0 FRAME
(b)
ODU
(See IMC 0256BEDG)
A B
ND/HDe ND2
7 to 13 147.5 270.5 250
Ø75÷115mm POLE
1+0 FRAME
INSERT
(a)
1+0 FRAME
a) = THE INSERTS ARE NOT DELIVERED WITH THE FRAME, IF THIS FIXING IS REQUESTED THEY HAVE TO BE SEPARATELY PROVIDED
PROTECTION COVER
O-RING
(a)
PROTECTION COVER
7 534-108/69 UDR 84
8 534-108/69 UDR 84
ANTENNA
DIAMETER (m)
FREQUENCY P/N FEEDER
BAND
FLANGE
(GHz)
0,2 0,3 0,6 0,8 1,2
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ -
02 ¯ ¯ -
03 ¯ ¯ -
04 ¯ ¯ -
05 ¯ ¯ -
06 ¯ ¯ -
07 ¯ ¯ -
08 ¯ ¯ -
09 ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
INTEGRATED ANTENNA
for SRAL XD
(See Sheet 7)
OUTDOOR ASSEMBLY
(See IMC 0256BEDG)
FLEXIBLE WAVEGUIDE
(b)
(See IMC 0254BEDG)
1+1 FRAME
(See Sheets 2÷6)
- NOTE -
BRAIDED COAXIAL CABLE
(a) IF YOU WANT TO PASS TO
(See IMC 0257BEDG)
THE 1+1 INTEGRATED SYSTEM,
ORDER THE KIT 332-056/22
SINGLE-BOARD
INDOOR ASSEMBLY
(See IMC 0359BEDG)
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
1-8 9-16
ALMs USER Q-LAN V-LAN
T M C
ODU CABLE ODU CABLE
O C O C E N / PS
D B C D B C S / M
U L H U L H T W J
+ -
Ø75÷115mm POLE
1+1 FRAME
INSERT
(a)
a) = THE INSERTS ARE NOT DELIVERED WITH THE FRAME, IF THIS FIXING IS REQUESTED THEY HAVE TO
BE SEPARATELY PROVIDED
SRAL XD Single - Board 2 IMC 0358BEDG
LOW CAPACITY DIGITAL RADIO SYSTEM
INSTALLATION INFORMATION for
1+1 FRAME NOT INTEGRATED SYSTEM (7 to 38 GHz) Sheet 4
PROTECTION COVER
O-RING
(a)
PROTECTION COVER
ANTENNA
DIAMETER (m)
FREQUENCY P/N FEEDER
BAND
FLANGE
(GHz)
0.2 0.3 0.6 0.8 1.2
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ -
02 ¯ ¯ -
03 ¯ ¯ -
04 ¯ ¯ -
05 ¯ ¯ -
06 ¯ ¯ -
07 ¯ ¯ -
08 ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
P
USE ONLY THE SCREWS
U SUPPLIED WITH
THE ANTENNA
"VERTICAL" POLARIZATION
"HORIZONTAL" POLARIZATION
Ø 75÷115mm POLE
(recommended Ø 115mm)
P = PRESSURIZABLE FLANGE
U = UNPRESSURIZABLE FLANGE
P P U
U P P
U
U
STRAIGHT SECTION STRAIGHT SECTION
(c) (c)
PDR 70 (7 GHz)
Ø 115mm POLE
U = UNPRESSURIZABLE FLANGE
FLEXIBLE FLEXIBLE
FREQUENCY WAVEGUIDE KIT WAVEGUIDE KIT
(L. = 600 mm) (a) (L. = 1000 mm) (b) STRAIGHT
BAND
SECTION (c)
(GHz)
ATTENUATION
P/N ATTENUATION (dB) P/N (dB)
597-524/83 597-523/95
8
(UDR-PDR 84) 0,18 (UDR-PDR 84) 0,39 -
597-524/85 597-523/97
504-216/24
13 (UBR-PBR 120) 0,3 (UBR-PBR 120) 0,5
(UDR-PBR120)
(d) (d)
597-524/86 597-523/98
15 (UBR-PBR 140) 0,396 (UBR-PBR 140) 0,66
(d) (d)
597-524/87 597-523/99
18
(UBR-PBR 220) 0,72 (UBR-PBR 220) 1,2
597-524/87 597-523/99
23
(UBR-PBR 220) 0,72 (UBR-PBR 220) 1,2
597-524/87 597-523/99
26
(UBR-PBR 220) 0,72 (UBR-PBR 220) 1,2
597-525/79 597-525/80
28
(UBR-PBR 320) 1,2 (UBR-PBR 320) 2
597-526/72 597-526/73
32
(UBR-PBR 320) 1,76 (UBR-PBR 320) 3,28
597-524/88 597-524/20
38 1,2 2
(UBR-PBR 320) (UBR-PBR 320)
a) = THIS FLEXIBLE WAVEGUIDE IS USED WITH ANTENNAS DIAMETERS UP TO 0.80 mt (2.5 ft.)
b) = THIS FLEXIBLE WAVEGUIDE IS USED WITH ANTENNAS DIAMETERS FROM 1.2 mt (4 ft.)
c) = THIS STRAIGHT SECTION IS USED WITH ANTENNAS DIAMETERS FROM 1.8 mt (6 ft.)
800
1000
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
02 ¯ ¯ ¯ ¯ ¯ ¯ -
03 ¯ ¯ ¯ ¯ ¯ -
04 ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
05 ¯ ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
P
"E" BEND 90° g
U (NB1)
"VERTICAL" POLARIZATION U
TWIST
U (NB1)
i
P
P
"E" BEND 90°
U (NB1)
g
U
P
P
"HORIZONTAL" POLARIZATION
WAVEGUIDE SUPPORT
d
NB1
Ø 75÷115mm POLE
(recommended Ø 115mm)
1+0 VERTICAL FRAME
or
UNIVERSAL CLAMP 1+1 SUPPORTING FRAME
and RUBBER BUSH
e f
(NB1)
WAVEGUIDE
CONNECTOR
a
(NB1)
P
SUPPORTING FRAME WITH PASSING HOLE
USE ONLY THE SCREWS SUPPLIED
U WITH THE WAVEGUIDE CONNECTOR
or
WHEN THE ODUs MUST BE INSTALLED INSIDE A SHELTER OR EQUIPMENT ROOM, THE WAVEGUIDE MUST BE
CONNECTED TO GROUND BEFORE ENTERING INSIDE THE SHELTER OR EQUIPMENT ROOM.
NB1 = FOR THE P/N see Sheets 4...6
FOR THE WAVEGUIDE PRESSURIZATION see Sheet 3
P P U
U U
TWIST
C
U (a)
P
m
STRAIGHT SECTION
m
STRAIGHT SECTION P
(a) (a)
P
PDR 70 (7 GHz)
Ø 115mm POLE
ELLIPTICAL WAVEGUIDE
1
(a)
WAVEGUIDE SUPPORT
UNIVERSAL CLAMP d
and RUBBER BUSH (a)
e f
(a)
P = PRESSURIZABLE FLANGE
U = UNPRESSURIZABLE FLANGE
WAVEGUIDE CONNECTOR
ODU SIDE
EXTERNAL DEHYDRATOR
(a)
633-051/68
DEHYDRATOR PIPE
(a)
NOTE
IT IS RECOMMENDED FOR WAVEGUIDE RUN OVER:
5m (7 GHz), 6m (8 GHz), 11m (13 GHz), 16m (15 GHz), 25m (18 GHz), 38m (23 GHz) and 45m (26-28-32-38 GHz)
• 8 GHz
ELLIPTICAL WAVEGUIDE (31263-758)
ITEM DESCRIPTION P/N Unit Q.ty
1 ELLIPTICAL WAVEGUIDE (EWP 77-77) 127-042/06 Mt. NOTE 1
2 ADAPTER FOR ANGULAR (10pz) 165-005/84 N° NOTE 1
3 WAVEGUIDE CLAMP (10pz) 165-005/70 N° NOTE 1
CONNECTORS AND ACCESSORIES (31263-779SR)
ITEM DESCRIPTION P/N Unit Q.ty
a WAVEGUIDE CONNECTOR (PDR 84) 504-237/87 N° 2
d WAVEGUIDE SUPPORT 332-055/21 N° 3
e UNIVERSAL CLAMP(∅62) 165-005/19 N° 3
f RUBBER BUSH (∅ 62) 332-202/87 N° 3
1
g 90° “E” BEND (UDR-UDR 84) 504-393/36 N°
NOTE 5
1
i TWIST (UDR-PDR 84) 504-631/21 N°
NOTE 2
1
g 90° “E” BEND (UBR-UBR120) 504-446/68K N°
NOTE 5
1
i TWIST (UBR-PBR 120) 504-656/52K N°
NOTE 2
1
m TRANSITION 504-216/23 N°
NOTE 6
• 15 GHz
ELLIPTICAL WAVEGUIDE (31263-767)
• 18 GHz
ELLIPTICAL WAVEGUIDE (31263-768)
ITEM DESCRIPTION P/N Unit Q.ty
1 ELLIPTICAL WAVEGUIDE (EWP 180) 127-042/10 Mt. NOTE 1
2 ADAPTER FOR ANGULAR (10pz) 165-005/84 N° NOTE 1
3 WAVEGUIDE CLAMP (10pz) 165-005/74 N° NOTE 1
• 23 GHz
ELLIPTICAL WAVEGUIDE (31263-769)
ITEM DESCRIPTION P/N Unit Q.ty
1 ELLIPTICAL WAVEGUIDE (EWP 220) 127-042/11 Mt. NOTE 1
2 ADAPTER FOR ANGULAR (10pz) 165-005/84 N° NOTE 1
3 WAVEGUIDE CLAMP (10pz) 165-005/74 N° NOTE 1
• 28 GHz
ELLIPTICAL WAVEGUIDE (31262-770)
ITEM DESCRIPTION P/N Unit Q.ty
1 ELLIPTICAL WAVEGUIDE (EWP 300) 127-041/26 Mt. NOTE 1
e UNIVERSAL CLAMP(∅ 38) 165-005/17 N° NOTE 1
f RUBBER BUSH FOR E 300 332-202/60 N° NOTE 1
CONNECTORS AND ACCESSORIES (31262-798SR)
ITEM DESCRIPTION P/N Unit Q.ty
a E 300 WAVEGUIDE CONNECTOR (PBR 320) 504-237/17 N° 2
a1 SILICONE SEALING FOR W/G CONNECTOR 104-104/04 N° 1
d WAVEGUIDE SUPPORT 332-055/21 N° 3
g 90° “E” BEND (UBR-UBR 320) 504-446/71K N° 1
i TWIST (UBR-PBR 320) 504-656/55K N° 1 NOTA 2
• 32 GHz
ELLIPTICAL WAVEGUIDE (31262-770)
ITEM DESCRIPTION P/N Unit Q.ty
2 ELLIPTICAL WAVEGUIDE (EWP 300) 127-041/26 Mt. NOTE 1
g UNIVERSAL CLAMP(∅ 38) 165-005/17 N° NOTE 1
h RUBBER BUSH FOR E 300 332-202/60 N° NOTE 1
CONNECTORS AND ACCESSORIES (31262-798SR)
ITEM DESCRIPTION P/N Unit Q.ty
b E 300 WAVEGUIDE CONNECTOR (PBR 320) 504-237/17 N° 2
a1 SILICONE SEALING FOR W/G CONNECTOR 104-104/04 N° 1
e WAVEGUIDE SUPPORT 332-055/21 N° 3
h 90° “E” BEND (UBR-UBR 320) 504-446/71K N° 1
i TWIST (UBR-PBR 320) 504-656/55K N° 1 NOTA 2
NOTE 1 = QUANTITY TO BE DEFINED AS PER PLANT REQUIREMENTS
NOTE 2 = OPTIONAL, USE FOR HORIZONTAL POLARIZATION ONLY
• 38 GHz
ELLIPTICAL WAVE GUIDE (31262-772)
ITEM DESCRIPTION P/N Unit Q. ty
1 ELLIPTICAL WAVE GUIDE (EWP 380) 127-041/25 Mt. NOTE 1
e UNIVERSAL CLAMP (ø 38) 165-005/17 N° NOTE 1
f RUBBER BUSH FOR E 380 332-202/93 N° NOTE 1
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
02 ¯ ¯ ¯ ¯ -
03 ¯ ¯ ¯ ¯ ¯ ¯ -
04 ¯ ¯ ¯ ¯ -
05 ¯ ¯ ¯ ¯ -
06 ¯ ¯ ¯ ¯ -
07 ¯ ¯ ¯ ¯ ¯ -
08 ¯ ¯ ¯ -
09 ¯ ¯ ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
OUTDOOR ASSEMBLY
ASSEMBLY ON SUPPORT FRAME
OUTDOOR ASSEMBLY
(See Sheets 2-3)
OUTDOOR ASSEMBLY
NORMAL DENSITY
and HIGH DENSITY ENHANCED
GROUNDING SCREW
(See IMC 0257BEDG)
(DOWN VIEW)
281
(SIDE VIEW)
(FRONT VIEW)
123
238
267
RX FIELD MEASURE
CONNECTOR IN/OUT CABLE
(See Sheet 7) CONNECTOR
(See IMC 0257BEDG) FOR FEEDER FLANGE
See Sheet 4
OUTDOOR ASSEMBLY
NORMAL DENSITY 2
102
(DOWN VIEW)
HANDLE
262 (TO USE FOR THE TRANSPORT)
235
275
235
OUTDOOR ASSEMBLY
SHIFTER, P/N and FLANGE
8 119 / 126
732-251/08 732-241/08E - UDR 84
(7.7 ÷ 8.5) 266 / 311.25
13
266 732-251/13 732-241/13E - UBR 120
(12.75 ÷ 13.25)
23
1008 / 1200 / 1232 732-251/23 732-241/23E 732-251/23E UBR 220
(21.2 ÷ 23.6)
26
1008 732-251/26 732-241/26E - UBR 220
(24.5 ÷ 26.5)
28
1008 732-251/28 732-241/28E - UBR 320
(27.5 ÷ 29.5)
32
812 - 732-241/32E - UBR 320
(31.8 – 33.4)
38
1260 732-251/38 732-241/38E, F (b) 732-251/38E UBR 320
(37.0 ÷ 39.5)
OUTDOOR ASSEMBLY
"VERTICAL" POLARIZATION APPLICATION
NORMAL DENSITY
and HIGH DENSITY ENHANCED
RX FIELD MEASURE
CONNECTOR
(REAR VIEW)
GROUND
IN/OUT CABLE
CONNECTOR
NOTE = FOR "VERTICAL" POLARISED APPLICATION, THE IN/OUT CABLE CONNECTOR IS AT BOTTOM
OUTDOOR ASSEMBLY
"HORIZONTAL" POLARIZATION APPLICATION
NORMAL DENSITY
and HIGH DENSITY ENHANCED IN/OUT CABLE
CONNECTOR
(REAR VIEW)
GROUND
RX FIELD MEASURE
CONNECTOR
NOTE = FOR "HORIZONTAL" POLARISED APPLICATION, THE IN/OUT CABLE CONNECTOR IS ON RIGHT HAND SIDE
OUTDOOR ASSEMBLY
"VERTICAL" POLARIZATION APPLICATION
NORMAL DENSITY 2
GROUND IN/OUT CABLE
CONNECTOR
(REAR VIEW)
RX FIELD MEASURE
CONNECTOR
NOTE = FOR "VERTICAL" POLARISED APPLICATION, THE IN/OUT CABLE CONNECTOR IS AT BOTTOM
OUTDOOR ASSEMBLY
"HORIZONTAL" POLARIZATION APPLICATION
NORMAL DENSITY 2
GROUND
RX FIELD MEASURE
CONNECTOR
(REAR VIEW)
IN/OUT CABLE
CONNECTOR
NOTE = FOR "HORIZONTAL" POLARISED APPLICATION, THE IN/OUT CABLE CONNECTOR IS ON RIGHT HAND SIDE
OUTDOOR ASSEMBLY
"RX FIELD MEASURE"
CONNECTOR
RX FIELD MEASURE
CONNECTOR
(a)
"BNC" SOCKET
a) = THIS "RX FIELD MEASURE" CONNECTOR IS THE TEST POINT FOR THE CONNECTION OF A VOLT METER DURING THE
ANTENNA ALIGNMENT PROCEDURE
OUTDOOR ASSEMBLY
REVISION LIST
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
02 ¯ ¯ ¯ -
03 ¯ ¯ ¯ ¯ -
04 ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
05 ¯ ¯ ¯ -
06 ¯ ¯ ¯ ¯ -
07 ¯ ¯ -
08 ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
IN/OUT BRAIDED
(a) COAXIAL CONNECTOR
COAXIAL CABLE (a)
90° "N" type
COAXIAL CONNECTOR
(a)
90° "SMA" type IDU ASSEMBLY
GROUNDING KIT
(a) (c)
GROUND CABLE
1x16mm² PVC YE-GR
(d)
(103-037/50)
(e) GROUNDING PLATE
333-047/07
GENERAL
GROUNDING POINT
INDOOR
BENDING RADIUS
see Sheet 8
BRAIDED COAXIAL CABLE
(a)(b)
TO CONNECT
TO THE STATION
GROUNDING SYSTEM
a) = FOR P/N see Sheet 7
b) = FOR THE FIXING OF THE BRAIDED COAXIAL CABLE see Sheet 5
c) = N°1 GROUNDING KIT IS A STANDARD SOLUTION FOR A BRAIDED COAXIAL CABLE TYPICAL PATH <50m,
THE USE OF ADDITIONAL GROUNDING KITS HAS TO BE EVALUTED ACCORDING TO THE PATH TYPE
USE THE CABLE STRIPPING TOOL 236-100/89
d) = THIS CABLE IS SUPPLIED WITH THE INSTALLATION MATERIALS
e) = OPTIONAL ITEM, IF REQUIRED MUST BE SEPARATELY PROVIDED
GROUND CABLE
1x16mm² PVC YE-GR
(d)
(103-037/50)
GENERAL
GROUNDING
POINT
INDOOR
BENDING RADIUS
see Sheet 8
BRAIDED COAXIAL CABLE
(a)(b)
TO CONNECT
TO THE GROUNDING
STATION SYSTEM
a) = FOR P/N see Sheet 7
b) = FOR THE FIXING OF THE BRAIDED COAXIAL CABLE see Sheet 5
c) = N°1 GROUNDING KITS ARE A STANDARD SOLUTION FOR A BRAIDED COAXIAL CABLE TYPICAL PATH <50m,
THE USE OF ADDITIONAL GROUNDING KITS HAS TO BE EVALUTED ACCORDING TO THE PATH TYPE
USE THE CABLE STRIPPING TOOL 236-100/39
d) = THIS CABLE IS SUPPLIED WITH THE INSTALLATION MATERIALS
e) = OPTIONAL ITEM, IF REQUIRED MUST BE SEPARATELY PROVIDED
(f) = FOR THE FIXING OF THE GROUND PLATE see Sheet 4
32 25
50
(a) TIE
223-002/86 PLATE (a)
332-004/92
GROUNDING PLATE
(a)
257-41/507
127
9÷
Ø7 (a)
HEX NUT
CABLE TIE
(b)
(223-009/25)
or INDOOR
UNIVERSAL
CABLE TIE CABLE CLAMP
(a) (b)
(223-009/27) (332-202/95)
(332-202/96)
71
52,5
Max 22
Max 22
WARNING
38 38
USE THE STRAP PLIER
236-100/50 for 2 3/10" Cables for 4 3/10" Cables
332-202/95 332-202/96
a) = N° 5 EXTERNAL BLACK TIE, FOR THE FIXING OF THE CABLE RUNNING ON THE POLE, ARE INCLUDED IN THE INSTALLATION KIT
Clamp spacing recommendation is based on the guidelines stated in EIA Standard RS-222
(Structural Standards for Steel Antenna Towers and Antenna Supporting Structures) and BSI
CP3 (Code of Basic Data for the Design of Buildings, Wind Loading).
Geographical location, as well as height of tower/must, to which the clamps are attached, may
have a significant impact on installation conditions.
Therefore, unless otherwise specified, the assumptions made to define the maximum clamp
spacing are the following:
• Tower height 45m
• 1/2” radial ice
• Clamps properly installed and tightened
Based on the above conditions, the recommended MAXIMUM CLAMP SPACING for BRAIDED
COAXIAL CABLE type CNT 300FR (Andrew) and ICN48 (INTERCOND) is 0,5m
104-009/50
CNT300 - 50 Ohm BRAIDED COAXIAL CABLE Mt. (b)
314-331/88 (b)
597-525/59A
BRAIDED COAX CABLE ACCESSORIES Nr. (c)
597-525/59 (b)
FOR THE ASSEMBLING INSTRUCTIONS SEE THE INFORMATION PROVIDED WITH THE CONNECTOR
OR
104-009/51
INC48 - 50 Ohm BRAIDED COAXIAL CABLE Mt. (c)
314-331/88 (b)
597-525/59B
BRAIDED COAXIAL CABLE ACCESSORIES Nr. (d)
597-525/59 (b)
421-025/31 90° COAX SMA-PLUG 1
FOR THE ASSEMBLING INSTRUCTIONS SEE THE INFORMATION PROVIDED WITH THE CONNECTOR
a) = The ANDREW and INTERCOND material sets are alternative to each other
b) = Commercial reference code
c) = The max length of one IDU/ODU connection is 200 mt (140 mt for IDU 32xE1)
d) = Q.ty 1 for each IDU/ODU connection
1. Construction Characteristics
ANDREW INTERCOND
Inner Conductor Diameter (mm) 1.78 1.78
Dielectric Diameter (mm) 4.83 4.90
Outer Conductor Diameter (mm) 4.98 6.00
Standard Jacket Diameter (mm) 7.62 7.60
2. Mechanical Characteristics
ANDREW INTERCOND
Weight (kg/m) 0.08 0.095
Min. Bending Radius single bend (mm) > 22.2 > 25
Tensile Strength (kg) 120 50
Bending Moment (N • m) 0.52 -
Crash Strength (kg/mm) 0.54 -
Max. Standard Hanger Spacing (m) 1 -
3. Range of Temperature
ANDREW INTERCOND
Recommended Temperature for Installation (°C) - 40 / + 85 - 40 / + 85
Recommended Storage for Installation (°C) - 70 / + 85 - 40 / + 85
Operating Temperature (°C) - 40 / + 85 - 40 / + 85
4. Electrical Characteristics
ANDREW INTERCOND
Characteristics Impedance (Ω) 50 50
Relative Propagation Velocity (%) 85 -
Capacitance (pF/m) 79.10 -
Maximun Operating Frequency (Mhz) 2450 -
Peak Power Rating (kW) 10 10
DC Resistance : Inner Conductor (Ω/km) 6.9 7.20
DC Resistance : Outer Conductor (Ω/km) 7.25 5.32
DC Breakdown (V) 2000 -
Inductance (µH/m) 0.20 0.20
(Continue)
6. Average Power Rating, kW Standard conditions : VSWR 1.0 ; ambient temperature 40°C ;
inner conductor temperature 100°C ;
ANDREW INTERCOND
30 MHz 2.10 -
50 MHz 1.60 -
150 MHz 0.92 -
450 MHz 0.52 -
900 MHz 0.36 -
1500 MHz 0.28 -
2000 MHz 0.24 -
2300 MHz 0.22 -
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
02 ¯ ¯ ¯ ¯ ¯ ¯ -
03 ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
04 ¯ ¯ ¯ -
05 ¯ ¯ ¯ ¯ ¯ ¯ -
06 ¯ ¯ ¯ -
07 ¯ ¯ ¯ ¯ ¯ ¯ -
08 ¯ ¯ ¯ -
09 ¯ ¯ ¯ -
10 ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
1/4" IN/OUT
COAXIAL CABLE
IDU ASSEMBLY
NOTE = The max lenght of one IDU/ODU connection is 300 mt (220 mt for IDU 32xE1)
(FRONT VIEW)
GROUNDING KIT
(a) (c)
GROUND CABLE
1x16mm² PVC YE-GR
(d)
(103-037/50)
(e) GROUNDING PLATE
333-047/07
GENERAL
GROUNDING POINT
INDOOR
BENDING RADIUS
see Sheet 10
1/4" COAXIAL CABLE
(a)(b)
TO CONNECT
TO THE STATION
GROUNDING SYSTEM
GROUND CABLE
1x16mm² PVC YE-GR
(d)
(103-037/50)
GENERAL
GROUNDING
POINT
INDOOR
BENDING RADIUS
see Sheet 10
1/4" COAXIAL CABLE (a) (b)
TO CONNECT
TO THE GROUNDING
STATION SYSTEM
a) = FOR P/N see Sheet 9
b) = FOR THE FIXING OF THE 1/4" COAXIAL CABLE see Sheet 6
c) = N°1 GROUNDING KITS ARE A STANDARD SOLUTION FOR A 1/4" COAXIAL CABLE TYPICAL PATH <50m,
THE USE OF ADDITIONAL GROUNDING KITS HAS TO BE EVALUTED ACCORDING TO THE PATH TYPE
d) = THIS CABLE IS SUPPLIED WITH THE INSTALLATION MATERIALS
e) = OPTIONAL ITEM, IF REQUIRED MUST BE SEPARATELY PROVIDED
f) = FOR THE FIXING OF THE GROUND PLATE see Sheet 5
32 25
50
(a) TIE
223-002/86 PLATE (a)
332-004/92
GROUNDING PLATE
(a)
257-41/507
127
9÷
Ø7 (a)
HEX NUT
INDOOR
UNIVERSAL
CABLE TIE CABLE CLAMP
(a) (c) (b)
(223-009/27) (332-202/65)
(332-202/66)
71
52,5
Max 22
Max 22
D = 74 ÷ 140 mm 223-009/27
38 38
a) = N° 5 EXTERNAL BLACK TIE, FOR THE FIXING OF THE CABLE RUNNING ON THE POLE, ARE INCLUDED IN THE INSTALLATION KIT
Clamp spacing recommendation is based on the guidelines stated in EIA Standard RS-222
(Structural Standards for Steel Antenna Towers and Antenna Supporting Structures) and BSI
CP3 (Code of Basic Data for the Design of Buildings, Wind Loading).
Geographical location, as well as height of tower/must, to which the clamps are attached, may
have a significant impact on installation conditions.
Therefore, unless otherwise specified, the assumptions made to define the maximum clamp
spacing are the following:
• Tower height 45m
• 1/2” radial ice
• Clamps properly installed and tightened
Based on the above conditions, the recommended MAXIMUM CLAMP SPACING for 1/4”
COAXIAL CABLE type LDF1RN-50 (Andrew) is:
0,8m (Wind Load 200 Km/h) or 0,5m (Wind Load 240 Km/h).
TO GROUNDING BAR
N3 ETSI/19" RACK
IDU ASSEMBLY
COAXIAL N-PLUG
TO (a)
ODU SECTION STRAIGHT "N" type
1/4" COAXIAL
(a)
CABLE GROUND CABLE
YE-GR PVC 1x16 mm²
(b)
(b) CAGE NUT M6 (314-304/51)
THE FIGURE SHOWS AN EQUIPMENT WITH 2 BASE BAND; IN CASE OF ONE BASE BAND ONLY ONE IN/OUT CONNECTION IS PRESENT
a) = FOR THE P/N see Sheet 9
b) = THESE MATERIALS ARE INCLUDED IN THE KIT 332-011/35 SUPPLIED WITH THE EQUIPMENT
c) = THIS MATERIAL IS SUPPLIED WITH THE EQUIPMENT
ANDREW SET
104-009/42
1/4” LDF1RN - 50 Ω COAXIAL CABLE Mt. (b)
314-327/79 (a)
597-523/94A
1/4” COAX CABLE ACCESSORIES Nr. (c)
597-523/94 (a)
FOR THE ASSEMBLING INSTRUCTIONS SEE THE INFORMATION PROVIDED WITH THE CONNECTOR
a) = Commercial reference
b) = The length of one IDU/ODU connection is 300 mt Max (220 mt for IDU 32xE1)
c) = Q.ty 1 for each IDU/ODU connection
1. Construction Characteristics
ANDREW
Inner Conductor Diameter (mm) 2.6
Dielectric Diameter (mm) 6.7
Outer Conductor Diameter (mm) 7.7
Standard Jacket Diameter (mm) 9
2. Mechanical Characteristics
ANDREW
Weight (kg/m) 0.09
Min. Bending Radius single bend (mm) 38
Min. Bending Radius repeated bends (mm) 76
Number of Bends Min. (typical) 15 (30)
Tensile Strength (kg) 91
Bending Moment (N • m) 1.33
Max. Tensile Force (N) -
Crush Strength (kg/mm) 1.4
Max. Standard Hanger Spacing (m) 0.5
3. Range of Temperature
ANDREW
Recommended Temperature for Installation (°C) - 25 / + 60
Recommended Storage for Installation (°C) - 30 / + 80
Operating Temperature (°C) - 30 / + 80
4. Electrical Characteristics
ANDREW
Characteristics Impedance (Ω) 50
Relative Propagation Velocity (%) 87
Capacitance (pF/m) 76.8
Maximun Operating Frequency (Mhz) 15800
Cut-off Frequency (Mhz) -
Peak RF Voltage Rating (kV) 1.1
Peak Power Rating (kW) 12.1
DC Resistance : Inner Conductor (Ω/km) 5.15
DC Resistance : Outer Conductor (Ω/km) 3.33
DC Breakdown (V) 2200
Inductance (µH/m) 0.19
(Continue)
6. Average Power Rating, kW Standard conditions : VSWR 1.0 ; ambient temperature 40°C ;
inner conductor temperature 100°C ;
ANDREW
10 MHz -
30 MHz 3.38
100 MHz 1.85
150 MHz 1.51
200 MHz -
300 MHz 1.07
450 MHz 0.871
600 MHz 0.756
824 MHz 0.644
894 MHz 0.618
900 MHz -
960 MHz 0.579
1000 MHz 0.585
1500 MHz 0.477
1700 MHz 0.448
1800 MHz -
2000 MHz 0.413
2300 MHz 0.385
3000 MHz -
4000 MHz 0.292
6000 MHz 0.239
10000 MHz 0.185
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
02 ¯ ¯ ¯ -
03 ¯ ¯ ¯ ¯ ¯ -
04 ¯ ¯ ¯ ¯ ¯ ¯ -
05 ¯ ¯ -
06 ¯ ¯ ¯ ¯ ¯ -
07 ¯ ¯ -
08 ¯ ¯ ¯ ¯ ¯ -
09 ¯ ¯ ¯ ¯ ¯ ¯ -
10 ¯ ¯ ¯ -
11 ¯ ¯ ¯ -
12 ¯ ¯ ¯ ¯ ¯ ¯ ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
SINGLE - BOARD 2
INDOOR ASSEMBLY
RACK ASSEMBLY
SINGLE - BOARD 2
INDOOR ASSEMBLY
732-102/71A,B,D
SINGLE - BOARD 2
INDOOR ASSEMBLY
GROUNDING CONNECTIONS
TO
STATION
EARTHING SYSTEM
GROUNDING CABLE
(6mm² L.= 400)
(b)
(314-303/56)
GROUNDING BAR
SPACING ROD
(c)
(211-483/79)
M4x10 CYLINDRICAL HEAD SCREW
(c)
(203-341/08D)
SINGLE-BOARD 2
INDOOR ASSEMBLY
MOUNTING BRACKET
for
19" RACK
SINGLE-BOARD 2
INDOOR ASSEMBLY
MOUNTING BRACKET
for
N3 ETSI RACK
SINGLE-BOARD 2
INDOOR ASSEMBLY
EQUIPMENT
CAUTION I O
! Vbattery
CAUTION CAUTION I O
! Vbattery ! Vbattery
CAPACITY
1+1 - 732-102/71D
SINGLE - BOARD 2
INDOOR ASSEMBLY
FUNCTIONS
CAUTION
! Vbattery I O
05 06 08 09 07 04a 02 A 01
CAUTION CAUTION I O
! Vbattery ! Vbattery
07 05 06 08 09 04a 04b 02 03 A 01
POWER SUPPLY
A I/O POWER ON - OFF -
MANAGEMENT SYSTEM
08 Q-LAN 10 Base T/100 Base Tx
Sheet 16
10 Base T/100 Base Tx or
09 V-LAN
VoIP Phone Sheet 19
07 LCT F INTERWORKING - S CHANNEL Sheet 15
SINGLE - BOARD 2
INDOOR ASSEMBLY
01
POWER SUPPLY
CONNECTIONS and PIN-OUT
IDU 8xE1 (only 1+0)
s SRAL XD
CAUTION I O
! Vbattery
01
IDU 16xE1 (1+0 or 1+1)
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
CAUTION CAUTION I O
! Vbattery ! Vbattery
01
PS
Pin A1
A1
FEMALE CONTACT
(a)
(422-027/31)
CRIMPING
SIDE VIEW
RECOMMENDED WIRING
MAXIMUM
POWER CONSUMPTION STATION SRAL XD
a) = THESE ACCESSORIES ARE CONTAINED IN THE POWER SUPPLY ACCESSORIES (332-055/28), PROVIDED WITH THE
IDU CONNECTION KIT-BASIC (597-525/16) see IMC 0361BEDG; FOR MOUNTING see IMC 0260BEDG
b) = THIS CABLE IS SUPPLIED WITH THE INSTALLATION MATERIALS, see IMC 0361BEDG
SINGLE - BOARD 2
INDOOR ASSEMBLY
04a 04b
75/120 Ohm TRIBUTARY INTERFACE
CONNECTIONS
CAUTION I O
! Vbattery
04a
CAUTION CAUTION I O
! Vbattery ! Vbattery
04a 04b
Pin 1
TRIBUTARY CABLE
8xE1 75 Ohm (L=5/10/20/30 m)
(a) (b) (c)
(314-331/35..38)
or
TRIBUTARY CABLE
8xE1 120 Ohm (L=5/10/20/30 m)
(a) (b) (d)
(314-331/79..82)
SINGLE - BOARD 2
INDOOR ASSEMBLY
04a 04b
75 Ohm TRIBUTARY INTERFACE
PIN-OUT
11
12
10
15
16
13
14
SINGLE- BOARD 2
INDOOR ASSEMBLY
04a 04b
120 Ohm TRIBUTARY INTERFACE
PIN-OUT
1 34
BU *
Tx DATA Wire b
18 BK
Tx DATA Wire a
CHANNEL no. 6 ( 14 )
2 35
OR *
Rx DATA Wire b
19 BK
Rx DATA Wire a
3 36
BN
*
Tx DATA Wire b
20 RD
Tx DATA Wire a
CHANNEL no. 5 ( 13 )
4 37
GY *
Rx DATA Wire b
21 RD
Rx DATA Wire a
5 38
GY *
Tx DATA Wire b
22 BK
Tx DATA Wire a
CHANNEL no. 8 ( 16 )
6 39
BU *
Rx DATA Wire b
23 YE
Rx DATA Wire a
7 40
GN *
Tx DATA Wire b
24 BK
Tx DATA Wire a
CHANNEL no. 7 ( 15 )
8 41
BN *
Rx DATA Wire b
25 BK
Rx DATA Wire a
9 42
GN *
Tx DATA Wire b
26 WH
Tx DATA Wire a
CHANNEL no. 2 ( 10 )
10 43
BN *
Rx DATA Wire b
27 WH
Rx DATA Wire a
11 44
BU
*
Tx DATA Wire b
28 WH
Tx DATA Wire a
CHANNEL no. 1 ( 9 )
12 45
OR *
Rx DATA Wire b
29 WH
Rx DATA Wire a
13 46
OR *
Tx DATA Wire b
30 RD
Tx DATA Wire a
CHANNEL no. 4 ( 12 )
14 47
GN *
Rx DATA Wire b
31 RD
Rx DATA Wire a
15 48
GY *
Tx DATA Wire b
32 WH
Tx DATA Wire a
CHANNEL no. 3 ( 11 )
16 49
BU *
Rx DATA Wire b
33 RD
Rx DATA Wire a
17 50
SINGLE - BOARD 2
INDOOR ASSEMBLY
05
ALARMS
CONNECTION
CAUTION
! Vbattery I O
05
CAUTION CAUTION I O
! Vbattery ! Vbattery
05
ALMs
Pin 1
RJ45 CONNECTOR
(a)
(422-053/63)
SINGLE - BOARD 2
INDOOR ASSEMBLY
05
ALARMS
PIN-OUT
ELECTRICAL DEFINITION
SINGLE - BOARD 2
INDOOR ASSEMBLY
06
USER
64 Kb/s V11
CONNECTION
CAUTION
! I O
Vbattery
06
CAUTION CAUTION I O
! Vbattery ! Vbattery
06
USER/Dext
Pin 1
RJ45 CONNECTOR
(a)
(422-053/63)
SINGLE - BOARD 2
INDOOR ASSEMBLY
06
USER/Dext
64 Kb/s V11
PIN-OUT
USER (a)
DIRECTION
PIN SIGNAL NAME
Co-Directional (a) Contra-Directional (a)
1 DATA Rx wire a input input
2 DATA Rx wire b input input
3 CLOCK Rx wire a input input
4 CLOCK Rx wire b input input
5 DATA Tx wire a output output
6 DATA Tx wire b output output
7 CLOCK Tx wire a output output
8 CLOCK Tx wire b output output
Dext (a)
Contra-Directional
DIRECTION
PIN SIGNAL NAME
Dext (a) Dext SRAL Compatible (a)
1 DATA Rx wire a input input
2 DATA Rx wire b input input
3 CLOCK Rx wire a input output
4 CLOCK Rx wire b input output
5 DATA Tx wire a output output
6 DATA Tx wire b output output
7 CLOCK Tx wire a input input
8 CLOCK Tx wire b input input
SINGLE - BOARD 2
INDOOR ASSEMBLY
07
LCT
(PERSONAL COMPUTER RS-232 INTERFACE)
CONNECTION
IDU 8xE1 (only 1+0)
s SRAL XD
CAUTION
! I O
Vbattery
07
IDU 16xE1 (1+0 or 1+1)
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
CAUTION CAUTION I O
! Vbattery ! Vbattery
Pin 1
07 LCT
F Interworking - S Channel
PERSONAL COMPUTER (Prefer the V-Bus connection)
RS-232 INTERFACE
to existing SRA L
(D01 Connector)
SINGLE - BOARD 2
INDOOR ASSEMBLY
08 09
QLAN / VLAN
10 Base T - 100 Base Tx
PIN-OUT
CAUTION
! Vbattery I O
08 09
CAUTION CAUTION I O
! Vbattery ! Vbattery
08 09
Q-LAN V-LAN
Pin 1
QLAN / VLAN
(10 Base T / 100 Base Tx)
SINGLE - BOARD 2
INDOOR ASSEMBLY
08 09
QLAN / VLAN
Q/VLAN CONNECTIONS
08 09 08 09 08 09
CONTROLLER CONTROLLER CONTROLLER
L max = 100m
GATEWAY N.E.
TNMS/NETVIEWER
IDU SRAL XD (b)
08
a) = IF THIS CONNECTION IS REQUESTED THE MATERIALS HAS TO BE SEPARATELY PROVIDED; see IMC 0361BEDG
b) = MAX 64 NETWORK ELEMENTS
SINGLE - BOARD 2
INDOOR ASSEMBLY
08 09
QLAN / VLAN
SWITCH CONNECTIONS
08 09 08 09 08 09
CONTROLLER CONTROLLER CONTROLLER
L max = 100m
TNMS/NETVIEWER
SINGLE - BOARD 2
INDOOR ASSEMBLY
09
IP PHONE (48Vdc / 220Vac)
Connection
(ON SPECIFIC REQUEST ONLY)
CAUTION I O
! Vbattery
09
CAUTION CAUTION I O
! Vbattery ! Vbattery
09
09
RJ45 CONNECTOR
SINGLE – BOARD 2
INDOOR ASSEMBLY
REVISION LIST
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ -
02 ¯ ¯ -
03 ¯ ¯ -
04 ¯ ¯ -
05 ¯ ¯ -
06 ¯ ¯ -
07 ¯ ¯ -
08 ¯ ¯ -
09 ¯ ¯ -
10 ¯ ¯ -
11 ¯ ¯ -
12 ¯ ¯ -
13 ¯ ¯ -
14 ¯ ¯ -
15 ¯ ¯ -
16 ¯ ¯ -
17 ¯ ¯ -
18 ¯ ¯ -
19 ¯ ¯ -
20 ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
b
c
IN d
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
44
CAUTION CAUTION I O
! Vbattery ! Vbattery
s SRAL XD
44
CAUTION I O
! Vbattery
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
44
CAUTION CAUTION I O
! Vbattery ! Vbattery
s SRAL XD
44
CAUTION I O
! Vbattery
1-8
2 Mbit/s I/O TRIBUTARIES
9-16
ALMs USER/Dext Q-LAN V-LAN
ODU CABLE ODU CABLE T M C
O C O C E N / PS
D B C D B C S / M
U L H U L H T W J
a + -
b
s SRAL XD
c LCT
2 Mbit/s I/O TRIBUTARIES 1-8
d + -
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
WARNING
Mount the WW Module with the
hook positioned in the bottom
FRONT VIEW
120 Ohm W.W. D.D.F. (a)
(232-334/92)
Wire-Wrap MODULE
(assembled on the TRIBUTARY CABLE)
COVER
(supplied with the D.D.F.)
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
CAUTION CAUTION I O
! Vbattery ! Vbattery + -
1÷8 TRIBUTARY INTERFACE 120 Ohm 9÷16 TRIBUTARY INTERFACE 120 Ohm
04a 04b
s SRAL XD
CAUTION I O
! Vbattery + -
a) = THIS MATERIAL IS SUPPLIED WITH THE INSTALLATION MATERIALS, see IMC 0361BEDG; FOR WIRING see SHEET 3
SINGLE-BOARD
INDOOR ASSEMBLY
IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT
1 5 9 13 1 5
2 6 10 14 2 6
4 8 12 16 4 8
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
1-8 9-16
ALMs USER/Dext Q-LAN V-LAN
T M C
ODU CABLE ODU CABLE
O C O C E N / PS
D B C D B C S / M
U L H U L H T W J
+ -
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
LCT 1-8
ALMs USER/Dext Q-LAN V-LAN T M C
ODU CABLE
O C E N / PS
D B C S / M
U L H T W J
+ -
1 5 9 13 1 5
2 6 10 14 2 6
3 7 11 15 3 7
4 8 12 16 4 8
LCT
s SRAL XD
2 Mbit/s I/O TRIBUTARIES
CAUTION CAUTION I O
! Vbattery ! Vbattery
s SRAL XD
CAUTION I O
! Vbattery
a) = THESE MATERIALS and 16 Coaxial Plug 1.0/2.3 (421-015/60) ARE INCLUDED IN THE 16xE1 75 Ohm Tributary Cable KIT(332-055/42)
b) = THESE MATERIALS and 8 Coaxial Plug 1.0/2.3 (421-015/60) ARE INCLUDED IN THE 8xE1 75 Ohm Tributary Cable KIT(332-055/41)
c) = THIS MATERIAL IS SUPPLIED WITH THE INSTALLATION MATERIALS, see IMC 0361BEDG
Coaxial Module
Pin on Sub-D Description Coax Cable 1st 2nd
1÷8/9÷16 No. 1÷8 9÷16
29 DATA Out Rx1 OUT1 OUT1 OUT9
Ch.1 Ch.9
28 DATA In Tx1 IN1 IN1 IN9
1÷8 9÷16
Channel on Connector
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ -
02 ¯ ¯ -
03 ¯ ¯ -
04 ¯ ¯ -
05 ¯ ¯ -
06 ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
(FRONT VIEW)
A3
A1
FEMALE CONNECTOR
(422-060/16)
FEMALE CONTACT
(422-027/31)
CRIMPING
( SIDE VIEW
)
1 - Remove the sheath to a length suitable for the dimensions of the ferrule.
BRAID SHEATH
2 - Insert the cable through the CABLE-RING and through the CONTACT RING.
BRAID SHEATH
CONTACT CABLE-RING
RING
BRAID SHEATH
CONTACT CABLE-RING
RING 6.5
BRAID SHEATH
CONTACT
RING
5 - Cut the METAL BRAID to a length of 9-10 mm and bend it back to cover the CONTACT RING
BRAID
SHEATH
CONTACT
RING
4mm
7 - Insert the two unsheathed wires into the FEMALE CONTACTS (422-027/31) as shown on the drawing.
FEMALE CONTACTS
(422-027/31)
and crimp them with the CRIMP TOOL 323-003/19 (See IMC 0262BEDG)
8 - Insert the contact with the 1-brand cable set to pos. "A1" and the contact with the 2-brand cable set to pos."A3",
ascertain that the contacts are securely snap-fastened into position.
A3
A1
2
1
9- Insert the whole (i.e. cable and connector) into the METALLIC SHELL as stated at pages 11...14
1. Insert the HEATSHRINK SLEEVE with length 40 mm on the cable and trim the
OUTER SHEATH according to the measures pointed out here below.
OUTER SHEATH
HEATSHRINK SLEEVE 95 mm
2. Trim the SHEATH, the BRAID, the DIELECTRIC and the CENTRAL CONDUCTOR of
all the eight single cables according to the measures pointed out here below.
HEATSHRINK SLEEVE 30 10 50 3
3. Position the HEATSHRINK SLEEVE on the OUTER SHEATH and on the INNER
ones, as pointed out here below.
HEATSHRINK SLEEVE
Heat the heatshrink sleeve ensuring that it adheres well on the inner and outer sheaths.
4. Connect the cable to the connector. Use a piece of the central conductor to execute the ground
inner connections.
5. Insert the cable and the connector into the METALLIC SHELL, as stated at pages 11 - 12 - 13 - 14.
Pay maximum attention to connect all the BRAIDS of the single cables to the cable clamp of the shell itself.
1 - Remove the sheath to a length suitable for the dimensions of the ferrule.
BRAID SHEATH
BRAID SHEATH
RUBBER
CABLE-RING
BRAID SHEATH
RUBBER
10
CABLE-RING
4 - Cut the METAL BRAID and the ground wire to a lenght of 10 mm to cover the sheath.
BRAID
METAL SHEATH
RIBBON
BRAID
SHEATH
6 - Locate the pair ground wires like the cable ground wire.
Do not made this operation if the pair ground wires are connected to the grounding point on the DDF.
BRAID
SHEATH
1a 1st Sh.
1b
16a
CONNECTOR
BRAID
SHEATH
RUBBER
CABLE-RING
CABLE GROUND
WIRE
8 - Fit both (cable and connector) into the METALLIC SHELL as stated at pages 15..18.
1 - Remove the sheath to a length suitable for the dimensions of the ferrule.
BRAID SHEATH
2 - Insert the cable through the CABLE-RING and through the CONTACT RING.
BRAID SHEATH
CONTACT CABLE-RING
RING
BRAID SHEATH
CONTACT CABLE-RING
RING 6.5
BRAID SHEATH
CONTACT
RING
5 - Cut the METAL BRAID and the ground wire to a lenght of 9-10 mm and bend them back over the contact ring.
BRAID
METAL SHEATH
RIBBON
CONTACT
GROUND
RING
WIRE
BRAID
SHEATH
CONTACT
GROUND
RING
WIRE
CONNECTOR
BRAID
SHEATH
GROUND
WIRE
7 - Fit both (cable and connector) into the shielded shell as stated at pages 15..18.
Fixing Screws
45°
Rubber Cable-Ring
49.4
4-40UNC-2A
A
E
B
CONTACTS A B C D E F
P/N
No. ±0.3 ±0.3 ±0.3 ±0.3 ±0.3 Max
1 - Fit both (cable and connector) into the shell and position the cable ring in its appropriate seat.
CABLE
CABLE-RING
RUBBER
METALLIC SHELL
CONNECTOR
CABLE
SCREW
CABLE CLAMP
3 - Fit the two FIXING SCREWS in the appropriate seats of the shell.
CABLE
FIXING
SCREW
FIXING
SCREW
4 - Close the two HALVES OF THE SHELL by pressing them together with a hand press
5 - Fix the two halves of the shell inserting and screwing a screw on both sides into the proper available seats
37.5
F
42.15 max
39.15 max
33
8
18
D
4 max.
C
A B
CONTACTS DIMENSIONS
P/N
No. max A max B C D E max F
1 - Fit both (cable and connector) into the shielded shell and position the cable ring in its appropriate seat.
CABLE
CABLE-RING
SHIELDED SHELL
CONNECTOR
2 - Fix the CABLE CLAMP with the three screws supplied. Each shell is equipped with two different cable clamps.
Choose the more suitable for the size of the cable and discard the other one in accordance with the table below.
A 5-8
422-030/92 15
B 8 - 10
SCREW
CABLE CLAMP
3 - Fit the two FIXING SCREWS in the appropriate seats of the shell.
FIXING
SCREW
FIXING
SCREW
4 - Close the two HALVES OF THE SHELL by pressing them together with a hand press
1 - Insert the ferrule over the cable and cut the sheath, the braid, the dielectric and central conductor
according to the measurements indicated here below
12.5 -0.5
2 - Introduce the central conductor until resting on the dielectric, crimp by crimp tool
(236-100/40)
inspection hole
0.7
3 - Introduce the central conductor in the coaxial plug until the central conductor blocks
arrange the braid on plug body and push the ferrule until it rests against the plug
crimp by crimp tool 236-100/40 (See IMC 0262BEDG)
3.8 x 8
1 - Put the protection plastic shell of the connector over the cable
25mm
3 - Bend back the braided shield over the cable sheath and remove the tinfoil shield.
5 - Cut the wires with accuracy as shown in figure by means of the provided tool 236-100/17 (See IMC 0262BEDG)
15mm
6 - Insert the cable into the connector taking care each single wire is properly placed.
Push the wires in position
The connector transparency allows to verify the correctness of the operation
7 - Insert the connector in the crimping matrix of the tool and crimp the connector executing the proper
pressure until the limit
RJ45
SHIELD TO BE REMOVED
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ ¯ ¯ ¯ ¯ -
02 ¯ ¯ -
03 ¯ ¯ -
04 ¯ ¯ -
05 ¯ ¯ ¯ -
06 ¯ ¯ ¯ -
07 ¯ ¯ ¯ -
08 ¯ ¯ -
09 ¯ ¯ -
10 ¯ ¯ -
11 ¯ ¯ -
12 ¯ ¯ -
13 ¯ ¯ -
14 ¯ ¯ -
15 ¯ ¯ -
16 ¯ ¯ -
17 ¯ ¯ -
18 ¯ ¯ -
19 ¯ ¯ ¯ ¯ ¯ -
20 ¯ ¯ ¯ ¯ ¯ -
21 ¯ ¯ ¯ ¯ -
22 ¯ ¯ ¯ ¯ -
23 ¯ ¯ ¯ -
24 ¯ ¯ ¯ ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
INSTALLATION MATERIALS
Standard for 2Mbit/s 75 Ohm (Sub-D) Tributary
INSTALLATION MATERIALS
Standard for 2Mbit/s 120 Ohm (Sub-D) Tributary
INSTALLATION MATERIALS
Optional
Alarm Connection
LAN Connection
INSTALLATION MATERIALS
Compositions
IDU Connection Kit-Basic
597-525/16
ITEM P/N DESCRIPTION Q.ty
1 332-055/28 Power Supply Accessories 1
1.1 422-060/16 DM Connector 3s AP 1
1.2 422-027/31 HP Female Contact 2
1.3 422-030/82 45° Metallic Shell for Sub-D 15c 1
2 314-303/56 Ground Cable 1
3 314-205/76 Installation Kit 1
3.1 223-009/16 Cable tie for internal L=280mm (1.7÷77) 20
3.2 215-031/70 Uninsulated tube term. Ø6.4 for 16mm² cable 5
3.3 203-343/15D Stainless steel screw M6x22 3
3.4 207-510/11D Stainless steel washer Ø6 3
3.5 207-501/11D Stainless steel spring washer Ø6 3
3.6 206-702/14D Stainless steel hex nut Ø6 3
3.7 223-009/27 Cable tie for external L=508mm (74÷140) 5
4 216-42/102 Metal Label 2
5 216-42/103 Metal Label 2
INSTALLATION MATERIALS
Compositions
a = The ANDREW and INTERCOND material sets are alternative to each other
b = Commercial reference
c = The length of one IDU/ODU connection is 200 Mt. Max.
for length up to 300m the 1/4" Coax Cable is available on request (refer to IMC 0258BEDG)
d = Q.ty 1 for each IDU/ODU connection
INSTALLATION MATERIALS
REVISION LIST
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ -
02 ¯ ¯ -
03 ¯ ¯ -
04 ¯ ¯ -
05 ¯ ¯ -
06 ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
SPECIAL TOOLS
USER TABLE
Crimping P.I./S.B./
1. 323-003/19 - - - - 2
tool S.B.2
Crimping
2. 236-100/40 - P.I./M.I. - - - 3
tool
Crimping P.I./S.B./
3. 236-100/17 - - - - 4
tool S.B.2
Cable
P.I./S.B./
4. 236-100/39 stripping - - - S.B.2/M.I.
- 5
tool
P.I./S.B./
5. 236-100/50 Strap Plier - - - S.B.2/M.I.
- 6
Wire cut
P.I./S.B./
6. 236-100/54 and strip - - - - S.B.2
7
tool
Hand
P.I./S.B./
7. 236-100/55 wrapping - - - -
S.B.2
8
tool
SPECIAL TOOL
CRIMPING TOOL (323-003/19)
for
POWER SUPPLY CONNECTOR
(422-060/16, 422-027/31)
THE SPECIAL TOOL CONSISTS OF ONE CRIMP TOOL AND TWO MATRIX
The CRIMP TOOL is used for crimping the POWER SUPPLY CONNECTOR to the 2x1.5 mm² BIPOLAR
SHIELDED CABLE (105-013/02).
SPECIAL TOOL
CRIMPING TOOL (236-100/40)
for
COAXIAL PLUG (421-015/60)
The CRIMP TOOL is used for crimping the COAXIAL PLUG (421-015/60),
to the COAXIAL CABLE (104-102/22-23)
* WARNING * = ONE CRIMPING TOOL HAS TO BE SUPPLIED FOR EACH INSTALLATION TEAM
SPECIAL TOOL
CRIMPING TOOL (236-100/17)
for
RJ45 CONNECTOR
(422-053/63)
CRIMPING TOOL
(Cod. MISCO A1287)
The CRIMPING TOOL is used for crimping the RJ45 SHIELDED CONNECTOR ON THE
Lan Cable (106-041/76)
SPECIAL TOOLS
CABLE STRIPPING TOOL (236-100/39)
for
GROUNDING KIT
(333-031/21-22)
SPECIAL TOOL
STRAP PLIER (236-100/50)
SPECIAL TOOL
WIRE CUT and STRIP TOOL (236-100/54)
for
120 Ohm Wire-Wrap D.D.F.
(232-334/92, 314-332/32)
The TOOL is used for CUT and STRIP the 120 Ohm MULTIPAIRS DOUBLE SHIELDED CABLE Ø 0.5 mm
on the 120 Ohm Wire-Wrap D.D.F. (232-334/92, 314-332/32)
SPECIAL TOOL
HAND WRAPPING TOOL (236-100/55)
for
120 Ohm Wire-Wrap D.D.F.
(232-334/92, 314-332/32)
The HAND TOOL is used for WRAPPING and UNWRAPPING the 120 Ohm MULTIPAIRS DOUBLE
SHIELDED CABLE on the 120 Ohm Wire-Wrap D.D.F. (232-334/92, 314-332/32)
SPECIAL TOOL
REVISION LIST
Revisions Revisions
Sheet Sheet
01 02 03 04 05 06 07 08 09 10 01 02 03 04 05 06 07 08 09 10
01 ¯ ¯ ¯ ¯ ¯ ¯ -
02 ¯ ¯ -
03 ¯ ¯ ¯ ¯ -
04 ¯ ¯ -
05 ¯ ¯ ¯ ¯ -
06 ¯ ¯ -
07 ¯ ¯ ¯ -
08 ¯ ¯ -
09 ¯ ¯ ¯ -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -