Professional Documents
Culture Documents
CODE
FAN
INTPUT
OUTPUT
TERMICA
220
(1)
(2)
(3)
(4)
VGF 2
METHANE GAS
GPL
HEAT UP
WEIGHT
(3)
Pa
kW
kW
m3/h
kg/h
min
l/h
l/10
l/60
kg
90
26
23,4
2,76
2,05
26
592
358
851
165
300
VGF 3
65
31
27,9
3,12
2,31
32
666
464
1019
195
400
VGF 4
64
31
27,9
3,12
2,31
42
666
582
1137
235
Standard equipment
Spare parts kit included as standard accessory.
Time of heating water from 15 to 65C
Production of DHW from 15 to 50 C with storage at 65C: continuous (l/h); rst 10 min peak (l/10), rst hour peak (l/60).
These sealed-combustion water heaters can be installed virtually anywhere because the fuel circuit is sealed and separated from
the room where they are located. The fan-forced-draught enables the simultaneous suctioning of the combustion air with exhaust
s 3EALED COMBUSTION
of the by-products of combustion outside the room, even without a ue or a chimney.
s &ORCE
DRAUGHT %. TYPE #
The equipment is tted with an electrical gas valve and electronic ignition with ionisation ame control. The various functions
are controlled and handled by an electronic switchboard. This system is designed to clean the fuel combustion chamber with
fresh air before every burner ignition. This process prevents any gas residue (especially in the event of liqueed gas) from causing
USE
potentially hazardous situations.
Water heater for production and
A differential pressure switch guarantees the immediate blockage of the gas ow and shuts off the burner in case of a bad
storage of Domestic Hot Water
working operation of the exhaust fume fan or of any other anomalous exhaust operation. Ignition can be programmed by using
(DHW).
Working temperature: max 65C. the weekly timer.
The equipment is tted with a double thermostat (operation and safety).
Working pressure: max 6 bar.
ANTICORROSIVE COATING
GLASS-LINING: inorganic coating
(VITREOUS ENAMEL) heated
to 950C, suitable for potable
water according to DIN 4753.3
standards.
IMPORTANT: EXTRACTION AND EXHAUST KIT TO BE ORDERED WITH THE WATER HEATER
Fumes are exhausted and air is vented by through a kit, which has been especially designed and
tested for our equipment. Available in coaxial version (horizontal or vertical) or in split horizontal
version. On request are also available 90 curves and 1 meter extensions that allow to t the kit
according to every kind of installation .
INSULATION
Glass wool, thickness 25 mm;
category 0.
EXTERNAL JACKET
Galvanized and plastic coated
steel; grey colour RAL 7035.
CATHODIC PROTECTION
Magnesium Anodes (AM) made of
special alloy AZ63, complete with
Anoden Tester (AT 1) for fast and
reliable check of anode operation
and consumption.
SAFETY
Sealed combustion environmentally safe; safety thermostat
to avoid any overheating and
exhaust fume control device (DCF)
against abnormal exhaust.
ELECTRIC POWER
230 V AC/50 Hz.
KSO
KSD
Air
KSV
Fumes
CODE
KSO
C 12
horizontal
KSV
C 32
vertical
KSD
C 52
split
VERSION
LITRES
coaxial
exhaust
coaxial
exhaust
horizontal
exhaust
DIMENSIONS mm
A
De
CONNS.
ac-af-r-sc
220
370
570
770
680
1130
100/60
1710
AM 4
183x79x79
370
570
770
680
1360
100/60
1950
AM 4
200x79x79
400
370
570
770
730
1520
100/60
2130
AM 4
220x83x83
hot water
cold water
circulation
drain
AM Magnesium Anode
B Stainless Steel multigas
burner with air draught
EV Electric fanned ue
PS Instrument panel with:
- Anoden Tester
- Weekly timer
- Push- button panel
- Operation thermostat
- Safety thermostat
T Thermometer
TF Flue tubes
ANTICORROSION WARRANTY
2 years.
Catalogue 2008
PACKING mm
300
ac
af
r
sc
24
ANODES
TYPE
VGF