You are on page 1of 11

Project:

Reference Number: Position

Company name:
Created by:
Phone:
Fax:
Date:

Client:
Client Number:
Contact:

Qty. Description
1

NB 125-315/277 AS-F-A-BAQE
Product No.: On request
Non-self-priming, single-stage, centrifugal volute pump designed according to ISO 5199 with
dimensions and rated performance according to EN 733 (10 bar). Flanges are PN 16 with
dimensions according to EN 1092-2. The pump has an axial suction port, radial discharge port,
horizontal shaft and a back pull-out design enabling removal of the motor, motor stool, cover and
impeller without disturbing the pump housing or pipework.
The unbalanced rubber bellows seal is according to DIN EN 12756.
The pump is close-coupled to a fan-cooled asynchronous motor.

Further product details


The back pull-out design means that the pump can be serviced by a single person without disturbing
the pump housing or pipe work.

The pump is to be secured to the foundation with bolts through the pump housing feet and motor
feet. The pump is delivered with steel support blocks enabling horizontal alignment of the pump and
ensuring a minimum clearence of 5 mm between the motor stool/motor flange and the foundation.
Cast-iron parts have an epoxy-based coating made in a cathodic electro-deposition (CED) process.
CED is a high-quality dip-painting process where an electrical field around the products ensures
deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the
process is a pretreatment. The entire process consists of these elements:
1) Alkaline-based cleaning.
2) Zinc phosphating.
3) Cathodic electro-deposition.
4) Curing to a dry film thickness 18-22 my m.
The colour code for the finished product is NCS 9000/RAL 9005.

Pump
The pump housing has both a priming and a drain hole closed by plugs.
The impeller is a closed impeller with double-curved blades with smooth surfaces. The impeller is
statically balanced according to ISO 1940-1 class G6.3 and hydraulically balanced to compensate
for axial thrust.
Wear rings used in pump housing and for impeller are made of bronze/brass or cast iron.
Motor stool and pump cover are made of cast iron (EN-GJL-250). Coupling guards are fitted to the
motor stool. The pump cover is provided with a manual air vent screw for venting of the pump
housing and the shaft seal chamber.
The pump is fitted with an unbalanced rubber bellows seal with torque transmission across the
spring and around the bellows. Due to the bellows, the seal does not wear the shaft, and the axial
movement is not prevented by deposits on the shaft.
Primary seal:
- Rotating seal ring material: Carbon graphite, metal-impregnated
- Stationary seat material: Silicon carbide (SiC)

Printed from Grundfos Product Centre [2014.08.045]

1/11

Project:
Reference Number: Position

Company name:
Created by:
Phone:
Fax:
Date:

Client:
Client Number:
Contact:

Qty. Description
This material pairing has a very good corrosion resistance and is especially suitable for water up to
+120 C. However, seal life will be reduced at temperatures above +90 C. The material pairing is
not recommended for liquids containing particles as this will result in heavy wear on the SiC face.
Secondary seal material: EPDM (ethylene-propylene rubber)
EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils.

Motor
The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN
standards. Electrical tolerances comply with IEC 60034.
The motor efficiency is classified as IE3 in accordance with IEC 60034-30.
The motor has thermistors (PTC sensors) in the windings in accordance with DIN 44081/DIN 44082.
The protection reacts to both slow- and quick-rising temperatures, e.g. constant overload and stalled
conditions.
Thermal switches must be connected to an external control circuit in a way which ensures that the
automatic reset cannot cause accidents. The motors must be connected to a motor-protective circuit
breaker according to local regulations.
A variable speed drive makes adjustment of pump performance to any duty point possible. If the
motor is to be connected to a variable speed drive, the pump should be ordered with an electrically
insulated motor bearing.

Technical data
Liquid:
Pumped liquid:
Liquid temperature range:
Liquid temp:
Density:
Kinematic viscosity:

Water
0 .. 120 C
20 C
998.2 kg/m
0 mm2/s

Technical:
Speed for pump data:
Actual calculated flow:
Resulting head of the pump:
Actual impeller diameter:
Impeller nom:
Shaft seal:
Secondary shaft seal:
Curve tolerance:

2980 rpm
361 m/h
101 m
277 mm
315 mm
BAQE
NONE
ISO 9906:1999 Annex A

Materials:
Pump housing:

Impeller:

Cast iron
EN-GJL-250
ASTM A48-40 B
Cast iron
EN-GJL-200
ASTM A48-30 B

Installation:
Maximum ambient temperature: 55 C
Maximum operating pressure: 16 bar
Flange standard:
EN 1092-2

Printed from Grundfos Product Centre [2014.08.045]

2/11

Project:
Reference Number: Position

Company name:
Created by:
Phone:
Fax:
Date:

Client:
Client Number:
Contact:

Qty. Description
Pump inlet:
Pump outlet:
Pressure stage:

DN 150
DN 125
PN 16

Electrical data:
Motor type:
IE Efficiency class:
Number of poles:
Rated power - P2:
Mains frequency:
Rated voltage:
Rated current:
Starting current:
Cos phi - power factor:
Rated speed:
Efficiency:
Motor efficiency at full load:
Motor efficiency at 3/4 load:
Motor efficiency at 1/2 load:
Enclosure class (IEC 34-5):
Insulation class (IEC 85):
Lubricant type:

SIEMENS
IE3
2
132 kW
50 Hz
3 x 380-420D/660-725Y V
230-210/134-122 A
10-10 %
0,9
2980 rpm
IE3 95,4%
95,4-95,4 %
95,6-95,6 %
95,2-95,2 %
55 (Protect. water jets/dust)
F
Grease

Others:
Minimum efficiency index, MEI : 0.69
ErP status:
EuP Standalone/Prod.
Net weight:
1130 kg
Gross weight:
1280 kg
Shipping volume:
2.35 m

Printed from Grundfos Product Centre [2014.08.045]

3/11

Project:
Reference Number: -

Company name:
Created by:
Phone:
Fax:
Date:

Client:
Client Number:
Contact:

NB 125-315/277 50 Hz
H
[m]

NB 125-315/277, 3*400 V, 50Hz

eta
[%]

Q = 361 m/h
H = 101 m
Pumped liquid = Water
Liquid temperature = 20 C
Density = 998.2 kg/m

120
110
100
90
80
70
60
50

100

40

80

30

60

20

40

10

20
Eta pump = 79.1 %

0
0

50

100

150

200

250

300

350

400

450

500

550

Q [m/h]

P2
[kW]

NPSH
[m]

140

35

120

30

100

25

80

20

60

15

40

10

20
0

Printed from Grundfos Product Centre [2014.08.045]

P2 = 125 kW
NPSH = 10.27 m

5
0
4/11

NB 125-315/277 AS-F-A-BAQE

Position
Product No:
EAN number:

On request
On request

Technical:
Speed for pump data:
Rated flow:
Rated head:
Actual impeller diameter:
Impeller nom:
Shaft seal:
Secondary shaft seal:
Shaft diameter:
Curve tolerance:
Pump version:

2980 rpm
382 m/h
82.2 m
277 mm
315 mm
BAQE
NONE
42 mm
ISO 9906:1999 Annex A
AS

Eta pump = 79.1 %


0

100

200

300

500

Q [m/h]
NPSH
[m]

100

20

50

P2 = 125 kW
NPSH = 10.27 m

10
0

1077
125

140
8 x 23
515
150
200

20

457
400
500
231
268

28
216

457

150
457

+T

RELAY

+T

SIEMENS
IE3
2
132 kW
50 Hz
3 x 380-420D/660-725Y V
230-210/134-122 A
10-10 %
0,9
2980 rpm
IE3 95,4%
95,4-95,4 %
95,6-95,6 %
95,2-95,2 %
55 (Protect. water jets/dust)
F

Printed from Grundfos Product Centre [2014.08.045]

400

+T

TO AMPLIFIER

L1

216

L2

+T

L3

+T

THERMISTORS PTC ACCORDING TO DIN 44082

0 .. 120 C
0 mm2/s

+T

140

CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY

Liquid:
Liquid temperature range:
Kinematic viscosity:

299

IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE

55 C
16 bar
EN 1092-2
F
DN 150
DN 125
PN 16
neckring(s)

374

8 x 19

Installation:
Maximum ambient temperature:
Maximum operating pressure:
Flange standard:
Connect code:
Pump inlet:
Pump outlet:
Pressure stage:
Wear ring(s):

Electrical data:
Motor type:
IE Efficiency class:
Number of poles:
Rated power - P2:
Mains frequency:
Rated voltage:
Rated current:
Starting current:
Cos phi - power factor:
Rated speed:
Efficiency:
Motor efficiency at full load:
Motor efficiency at 3/4 load:
Motor efficiency at 1/2 load:
Enclosure class (IEC 34-5):
Insulation class (IEC 85):

400

100
80
60
40
20
0

P2
[kW]

660

Material code:

Q = 361 m/h
H = 101 m
Pumped liquid = Water
Liquid temperature = 20 C
Density = 998.2 kg/m

471,0

Cast iron
EN-GJL-250
ASTM A48-40 B
Cast iron
EN-GJL-200
ASTM A48-30 B
A

eta
[%]

508

Impeller:

NB 125-315/277, 3*400 V, 50Hz

315

Materials:
Pump housing:

H
[m]
120
110
100
90
80
70
60
50
40
30
20
10
0

355

General information:
Product name:

280

Value

Client:
Client Number:
Contact:

150

Description

340

Project:
Reference Number: -

Company name:
Created by:
Phone:
Fax:
Date:

TO AMPLIFIER
RELAY

L1

L2

L3

5/11

Project:
Reference Number: Description

Value

Motor protec:
Motor No:
Mount. design. acc. IEC 34-7:
Lubricant type:

PTC
83U15446
IM B35
Grease

Others:
Minimum efficiency index, MEI :
ErP status:
Net weight:
Gross weight:
Shipping volume:

0.69
EuP Standalone/Prod.
1130 kg
1280 kg
2.35 m

Printed from Grundfos Product Centre [2014.08.045]

Company name:
Created by:
Phone:
Fax:
Date:

Client:
Client Number:
Contact:

6/11

Project:
Reference Number: -

Company name:
Created by:
Phone:
Fax:
Date:

Client:
Client Number:
Contact:

NB 125-315/277 50 Hz
Input
General
Application

Sizing result

Select Type of Installation


Select subapplication
Dimensioning flow
Total head

Industrial
applications
Pressure Boosting
Water-based
360 m/h
100 m

Your requirements
Pumped liquid
Min. liquid temperature
Liquid temperature during operation
Installation type
No of duty points

Water
10 C
20 C
Inlet pressure
1

Pump design
Immersible
Immersible horizontal
Submersible (Wastewater)
Inline Multistage
Inline single stage
End-suction long-coupled
End-suction close coupled
End-suction close coupled vertical
singlestage
End-suction close coupled horizontal
multistage
End-suction singlestage pump with
semi-open impeller MTB
Encapsulated
Horizontal splitcase

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Energy consumption
CO2 emission
Price
Price + energy costs

361
101
131
125
79.1
95.0
75.1
75.1

m/h ( +0%)
m ( +1%)
kW
kW
%
%
% =Eta pump * Eta motor
% =Eta relative to the duty
point
146280 kWh/Year
83400 kg/Year
On request
On request /5Years

H
[m]

NB 125-315/277, 3*400 V, 50Hz

120

Q = 361 m/h
H = 101 m
Pumped liquid = Water
Liquid temperature = 20 C
Density = 998.2 kg/m

110

eta
[%]

100

Yes
Yes

90
80
70

Yes
Yes

Control mode
Uncontrolled
Edit load profile
Load profile
Period
Operation hours per day
Consumption Q1
Consumption Q2
Consumption Q3
Consumption Q4
Consumption Q5
Consumption Q1
Consumption Q2
Consumption Q3
Consumption Q4
Consumption Q5
Time T1
Time T2
Time T3
Time T4
Time T5
Time T6
Time T7
Time T8

Type
NB 125-315/277
Quantity 1
Motor
132 kW
Flow
Head
Power P1
Power P2
Eta pump
Eta motor
Eta pump+motor
Eta total

Full load
Day
3.05 h/day
100.0 %
100.0 %
100.0 %
100.0 %
100.0 %
360 m/h
360 m/h
360 m/h
360 m/h
360 m/h
3.050 h/day
0.000 h/day
0.000 h/day
0.000 h/day
0.000 h/day
0 h/day
0 h/day
0 h/day

Printed from Grundfos Product Centre [2014.08.045]

60
50

100

40

80

30

60

20

40

10

20
Eta pump = 79.1 %

0
0

50

100

150

200

250

300

350

400

450

500

Q [m/h]

P2
[kW]

NPSH
[m]

150

30

100

20

50

10

P2 = 125 kW
NPSH = 10.27 m

7/11

Project:
Reference Number: Time T9
Time T10

Company name:
Created by:
Phone:
Fax:
Date:

Client:
Client Number:
Contact:

0 h/day
0 h/day

Configuration
Preferred number of poles
Electrical data
Frequency
Phase
Min. power limit for SD start
Voltage

Single
2
50 Hz
1 or 3
5.5 kW
1 x 230 or 3 x 400
V

Life cycle cost


Do you want to make a Comparison ?
How detailed do you want your Life Cycle
Cost analysis?

No comparison
Simple LCC
analysis

Hit list settings


Max. hits per product group
Max. hits total
Evaluation criterion
Include cheapest solution
Energy price
Increase of energy price
Calculation period

2
8
Preference index
Yes
0.18 GBP/kWh
6%
5 years

Load Profile
Flow
Head
P1
Eta total
Time
Energy consumption
Quantity

1
100
101
131
75.1
1113
146280
1

%
%
kW
%
h/a
kWh/Year

Printed from Grundfos Product Centre [2014.08.045]

8/11

Company name:
Created by:
Phone:
Fax:
Date:

Project:
Reference Number: -

Client:
Client Number:
Contact:

Installation and Input

Sizing Results
Type
NB 125-315/277
Quantity * Motor 1 * 132 kW
Flow
361 m/h ( +0%)
H total
101 m ( +1%)
Power P1
131 kW
Power P2
125 kW
Eta pump
79.1 %
Eta motor
95.0 %
Eta pump+motor
75.1 % =Eta pump * Eta motor
Flow total
401517 m/year
mm
mm
Energy consumption
146280 kWh/Year
Price
On request
Price + energy costs On request /5Years

Dimensioning flow: 360 m3/h

Pump Curve

Dimensional Drawing
NB 125-315/277, 3*400 V, 50Hz

120

Q = 361 m/h
H = 101 m
Pumped liquid = Water
Liquid temperature = 20 C
Density = 998.2 kg/m

110

eta
[%]

508

H
[m]

100
457

90

60

20

40

268

140

80

30

231

100

40

8 x 23

20

50

457
400
500

60

150

355
125

280

70

216

80

400
340
315

515

450

500

Q [m/h]
NPSH
[m]

150

30

100

20

140

P2
[kW]

10
P2 = 125 kW
NPSH = 10.27 m

Printed from Grundfos Product Centre [2014.08.045]

150

50

299

400

8 x 19

350

457

300

216

250

200

200

150

150

1077

100

471,0

50

660

28

20
Eta pump = 79.1 %

374

10

9/11

Project:
Reference Number: -

Company name:
Created by:
Phone:
Fax:
Date:

Client:
Client Number:
Contact:

Installation illustration

Dimensioning flow: 360 m3/h

Pressure Loss in Pipes

Printed from Grundfos Product Centre [2014.08.045]

10/11

Project:
Reference Number: -

Company name:
Created by:
Phone:
Fax:
Date:

Client:
Client Number:
Contact:

Order Data:
Product name:
Amount:
Product No:
Rated flow:
Rated head:
Actual impeller diameter:
Shaft seal arr.:
Shaft seal des.:
Shaft seal:
Sec. Shaft seal:
Bearing design:
Lubricant type:
Pump housing material:
Impeller material:
Pump version:
Material code:
Pump inlet:
Pump outlet:
Flange standard:
Liquid max temp:
Motor No:
Mains frequency:
Rated voltage:
Rated power - P2:

NB 125-315/277 AS-F-A-BAQE
1
On request
382 m/h
82.2 m
277 mm
Single
Standard
BAQE
NONE
17500 h
Grease
Cast iron
EN-GJL-250
Cast iron
EN-GJL-200
AS
A
DN 150
DN 125
EN 1092-2
120 C
83U15446
50 Hz
3 x 380-420D/660-725Y V
132 kW

Total: Price on request

Printed from Grundfos Product Centre [2014.08.045]

11/11

You might also like