Professional Documents
Culture Documents
Document No:
No of Pages.
TD/TR/GPON-FTTH/11-12
03
Issue No.
01
Issued By:
Approved By:
Date of Issue:
12.03.2012
INSPECTION CIRCLE
JABALPUR
Test case
Reference
Remarks
OF cable Termination.
Termination of OF cable on
splitter
Trench depth
ONT installation
Check of services
10
Interruption Test
11
Session stability
12
TD/TR/GPON-FTTH/11-12
Page 3 of 3
Issue-I
Dated 12.03.2012
INSPECTION CIRCLE
JABALPUR
13
Annexure-I
14
EI No.-EI/ACCESS NETWORK/11-12/13(House
wiring of FTTH) and P.O.
To avoid loss.
Annexure-I
Table 1. 1xN Symmetrical splitter optical specifications
The following optical specifications must be met under any combination of environmental,
mechanical and polarization conditions. All values listed in this table do not account for
connectors.
Splitter
1x2
1x4
1x5
1x6
1x8
1x10
1x12
1x16
1x24
1x32
1x64
Insertion Loss
Maximum (dB)
(CR)
Uniformity
Maximum (dB)
Operating
Wavelength
PDL (dB)
Return Loss (dB)
Directivity (dB)
Fibre Type
4.0
7.1
8.3
9.1
10.5
11.6
12.4
13.8
15.5
17.1
20.5
0.3
0.5
0.6
0.7
0.8
0.9
1.0
1.0
1.2
1.3
2.0
1260-1360nm/1480-1580nm*
< 0.2
> 55
> 55
Single-mode fibre
2x2
2x4
2x6
2x8
2x10
1x12
1x16
1x24
1x32
1x64
4.2
7.4
9.6
11.0
12.1
13.0
14.6
16.5
17.8
TBD
1.1
1.2
1.6
1.6
1.7
2.2
2.4
2.8
3.0
TBD
TD/TR/GPON-FTTH/11-12
1260-1360nm/1480-1580nm*
Page 2 of 3
Issue-I
Dated 12.03.2012
INSPECTION CIRCLE
JABALPUR
< 0.2
> 55
> 55
Single-mode fibre
PDL (dB)
Return Loss (dB)
Directivity (dB)
Fibre Type
NOTE I. Sharp bends to be avoided and all bends , conduits,ducts should correspond to EI No.EI/ACCESS NETWORK/11-12/13(House wiring of FTTH) and TR-SOFC-BWMF/T001 Dt 22.02.2010 (Blockwiring of multistory buildings for fibre)
II. Use of Existing and new electrical conduits are strictly banned.
TD/TR/GPON-FTTH/11-12
Page 3 of 3
Issue-I
Dated 12.03.2012