INSPECTION CIRCLE, SANCHAR VIKAS BHAWAN,

RESIDENCY ROAD, JABALPUR-482001 (MP)

ACCEPTANCE TESTING SCHEDULE


FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING

Document No:
No of Pages.

TD/TR/GPON-FTTH/11-12
03

Issue No.

01

Issued By:

Inspection Circle, Jabalpur

Approved By:

CGM, Inspection Circle

Date of Issue:

12.03.2012

Amendment No (If Any) NIL


No of Pages:
Issued by:
Date of Issue:
Restricted use by BSNL Employees only

INSPECTION CIRCLE
JABALPUR

FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING


TEST SCHEDULE

FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING


S No

Test case

Reference

Remarks

Check of Approved layout


diagram & documentation

Hard/Soft Copies to be checked

OF cable Termination.

OF cable to be terminated on FTB as per EI No.EI/ACCESS NETWORK/11-12/13(House wiring of


FTTH) and P.O.
OF cable should be neatly laced and labeling to be
done.

Termination of OF cable on
splitter

Drop fibers from FTB are to be laid with suitable


protection and termination on splitter as per EI No.EI/ACCESS NETWORK/11-12/13 (House wiring of
FTTH) and P.O.

Cabling from splitter to


ONT Location

Drop fibre can be layed to ONT location through


micro duct/PVC pipe with suitable clampings as per
EI No.- EI/ACCESS NETWORK/11-12/13 (House
wiring of FTTH) and P.O.

Trench depth

Sample pits to be taken and trenching depth should


be as per EI No.- D-001 Issue IV dated 31.01.2007
(Laying practices of Optical fibre cable)

Optical link budget

RX sensitivity > -28 dbm at ONT Location


Power Loss calculated is as below
(Length in KM X 0.34 db/KM)+(0.15 db X no of
connectors)+ (0.1 db X no of splices) + (3 db
margin of error). Splitter losses to be added.

ONT installation

ONT, UPS to be wall mounted near A/C supply


point as per EI No.-EI/ACCESS NETWORK/1112/13(House wiring of FTTH) and P.O.
Hardware/software conformity of installed
equipment to be verified as per BOM.

Connectivity details and IP


details.

OLT to ONT path connectivity details.

Check of services

Check services HSI, VOIP, IPTV, RF Overlay as per


the tariff plan.

10

Interruption Test

Physically isolated fibre at splitter/ONT and


reconnect.
System should start-up without any intervention.

11

Session stability

Session stability to be carried out for 2 hrs.

12

Verification of data speed


for Triple Play Services

FTTH is capable of data speed for downstream up to


2.4 Gbps and upstream up to 1.2 Gbps

TD/TR/GPON-FTTH/11-12

Page 3 of 3

Issue-I
Dated 12.03.2012

INSPECTION CIRCLE
JABALPUR

FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING


TEST SCHEDULE

13

Check for splitter


specifications

Annexure-I

14

Check of bending of Optical


cable

EI No.-EI/ACCESS NETWORK/11-12/13(House
wiring of FTTH) and P.O.
To avoid loss.

Annexure-I
Table 1. 1xN Symmetrical splitter optical specifications
The following optical specifications must be met under any combination of environmental,
mechanical and polarization conditions. All values listed in this table do not account for
connectors.
Splitter

1x2

1x4

1x5

1x6

1x8

1x10

1x12

1x16

1x24

1x32

1x64

Insertion Loss
Maximum (dB)
(CR)
Uniformity
Maximum (dB)
Operating
Wavelength
PDL (dB)
Return Loss (dB)
Directivity (dB)
Fibre Type

4.0

7.1

8.3

9.1

10.5

11.6

12.4

13.8

15.5

17.1

20.5

0.3

0.5

0.6

0.7

0.8

0.9

1.0

1.0

1.2

1.3

2.0

1260-1360nm/1480-1580nm*
< 0.2
> 55
> 55
Single-mode fibre

Table 2. 2xN Symmetrical splitter optical specifications


The following optical specifications must be met under any combination of environmental,
mechanical and polarization conditions. All values listed in this table do not account for
connectors.
Splitter
Insertion Loss
Maximum (dB)
(CR)
Uniformity
Maximum (dB)
Operating
Wavelength

2x2

2x4

2x6

2x8

2x10

1x12

1x16

1x24

1x32

1x64

4.2

7.4

9.6

11.0

12.1

13.0

14.6

16.5

17.8

TBD

1.1

1.2

1.6

1.6

1.7

2.2

2.4

2.8

3.0

TBD

TD/TR/GPON-FTTH/11-12

1260-1360nm/1480-1580nm*
Page 2 of 3

Issue-I
Dated 12.03.2012

INSPECTION CIRCLE
JABALPUR

FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING


TEST SCHEDULE

< 0.2
> 55
> 55
Single-mode fibre

PDL (dB)
Return Loss (dB)
Directivity (dB)
Fibre Type

NOTE I. Sharp bends to be avoided and all bends , conduits,ducts should correspond to EI No.EI/ACCESS NETWORK/11-12/13(House wiring of FTTH) and TR-SOFC-BWMF/T001 Dt 22.02.2010 (Blockwiring of multistory buildings for fibre)
II. Use of Existing and new electrical conduits are strictly banned.

TD/TR/GPON-FTTH/11-12

Page 3 of 3

Issue-I
Dated 12.03.2012