Figure1:TypicalBracedBaysinSimpleConstruction
FEBRUARY3,2015
FollowingthepublicationofAD275concerningcolumnsinsimpleconstructionfurtherquestionshavebeenasked
Steelputsregenerationingear
FEBRUARY3,2015
aboutthedesignofcolumnsinbracedbaysofsimplestructuresandtheuseofnominalmoments.ThisADis
writtenontheassumptionthatthecentrelinesofthemembersinthebracedbaysarecoincidentateachnodeand
thatthebeamcolumnbracingconnectionisdesignedanddetailedsothattheonlynominalmomentsthatarise
arefromtheassumedeccentricityofthebeamendreactions.
Calculatingthefabricationfootprint
FEBRUARY3,2015
Unlesssomeadditionalfactorsarisewhichmakesthecolumnaspecialcase,seeAD275,columnsinbracedbays
ofsimplestructuresshouldbedesignedinaccordancewithclause4.7.7ofBS59501:2000takingaccountof
nominalmoments.
Figure1showstypicalbracedbayswhichareusuallyanalysedaspinjointedframeswithallthemembersata
nodeintersectingatacommonpointontheircentrelinesinordertodeterminetheloadeffectsinthemembers
underverticalandlateralloading.
Assumingpinnedjointsinordertodetermineforcesinmembersignoresthenominalmomentsdescribedinclause
4.7.7ofBS59501:2000whichmustbetakenintoaccountinthedesignofcolumnsinsimplestructures.Inmost
casesthevalueofthenominalmomentiscalculatedfromtheassumed100mmeccentricityofthebeamend
reactionfromthefaceofthecolumnandthenetnominalmomentatanyleveldistributedassetoutinclause4.7.7.
Traditionally,whencalculationswereroutinelyperformedbyhand,thenominalmomentsforthecolumnswere
combinedwiththeaxialloadsinthecolumnsfromtheanalysisofthepinjointedframes.Thisshouldstillbedone
evenwhentheframeanalysisiscarriedoutusingsoftware.Atleastonecommerciallyavailablesoftwarepackage
combinestheaxialloadsandnominalmomentsinthecolumnsautomatically.However,designersshouldbe
carefulnottoignorethenominalmomentsinthedesignofthecolumnswhenanalysingthepinjointedframesfor
bracedbaysusinggeneralplaneframeanalysispackages.
AnotherADwillfollowshortlywhichwilldescribethecommoncaseswherethesettingsoutpointsofthediagonal
bracingmembersinbracedbaysaredisplacedfromtheintersectionofthecentrelinesofthebeamsandcolumns.
TaggedAdvisorydesk
http://www.newsteelconstruction.com/wp/ad304columnsinbracedbaysandnominalmoments/
1/2
2/14/2015
AD304:ColumnsinBracedBaysandNominalMoments|newsteelconstruction.com
Sharethispost
Tweet
Share
RelatedPosts
2015BarrettByrdAssociates.Allrightsreserved.
NewSteelConstructionisproducedbyBarrettByrdAssociatesonbehalfoftheBritish
ConstructionalSteelworkAssociation,TheSteelConstructionInstituteandTataSteel.
http://www.newsteelconstruction.com/wp/ad304columnsinbracedbaysandnominalmoments/
2/2