You are on page 1of 4

Code

Sub
Code

Description

Fixing temperature abnormal rise


E000 0001 The temperature detected by the main thermistor does not rise to the specified value
during startup control.
0000
E001 0001
0002

Fixing unit temperature rise detection


The reading of the main thermistor is 250 deg C or more continuously for 200 msec.
Fixing unit temperature rise detection
The hardware circuit detects overheating of the main or sub thermistor for 200 msec.
Fixing unit temperature rise detection
The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.

Fixing unit temperature insufficient rise


1.The reading of the main thermistor is less than 115 deg C continuously for 400 msec 1.3
E002 0000 sec after it has indicated 100 deg C.
2.The reading of the main thermistor is less than 150 deg C continuously for 400 msec 1.3
sec after it has indicated 140 deg C.
Low fixing temperature detection after standby
E003 0000 The reading of the main thermistor is less than 140 deg C continuously for 400 msec or
more.
E004 0000

E010

E014

Thermistor disconnection detection error


When disconnection is detected with connector (J214) for 30 sec continuously.

Unstable rotation of the Main Motor (M1)


0001 Detection is executed every 100 msec after the start of motor rotation; however, the drive
detection signal is absent for 2 sec.
Unstable rotation of the Main Motor (M1)
0002 During motor rotation, detection is executed every 100 msec; however, the drive signal is
absent 5 times in sequence.
Unstable rotation of the Fixing Motor (M2)
0001 Detection is executed every 100 msec after the start of motor rotation; however, the drive
detection signal is absent for 2 sec.
Unstable rotation of the Fixing Motor (M2)
0002 During motor rotation, detection is executed every 100 msec; however, the drive signal is
absent 5 times in sequence.

Error in Waste Toner Sensor (S17)


Warning when the sensor goes on for 2000 consecutive sheets, and error when the
E019 0000
sensor goes on for 100 consecutive sheets.
* Error occurs after the delivery if a paper in passage exists.
The path between the sub hopper and the developing assembly is clogged with toner.
The Developing Assembly Toner Sensor (TS1) detects the absence of toner,while the Sub
Hopper Toner Sensor (TS2) detects the presence of toner. With the Developing Cylinder
E020 0000 Clutch (CL3) turned on, the hopper feedscrew motor (M7) is rotated for 1 sec intermittently
194 times; still, theDeveloping Assembly Toner Sensor (TS1) does not detect the
presence of toner.
* Error occurs after the delivery if a paper in passage exists.
The connector (J207) of Developing Assembly Toner Sensor (TS1) is disconnected.
The Developing Assembly Toner Sensor (TS1) connection detection signal is absent for
0000
100 msec 10 times in sequence. * Error occurs after the delivery if a paper in passage
exists.
The Developing Assembly Toner Sensor (TS1) is disconnected
.<At LOW SPEED>
E024
- The developing assembly toner sensor (TS1) ON counter is checked every 2.5 seconds,
and the counter increments 1 count every 25 times when the sensor goes on, and 300
0001 counts are reached.
<At HIGH SPEED>
- The developing assembly toner sensor (TS1) ON counter is checked every 1.5 seconds,
and the counter increments 1 count every 15 times when the sensor goes on, and 300
counts are reached.

E025

The connector (J207) of Sub Hopper Toner Sensor (TS2) is disconnected.


The Sub Hopper Toner Sensor (TS2) connection detection signal is absent for 100 msec
0000
10 times in sequence.
* Error occurs after the delivery if a paper in passage exists.

0001

Failure of the Bottle Motor (M6)


The bottle motor (M6) is unlocked when it goes on for 12 consecutive times at 0.1 sec.
intervals.
* Error occurs after the delivery if a paper in passage exists.

Failure of the Scanner Motor (M21)


The Scanner Motor (M21) speed lock signal does not indicate a locked state a specific
0001
period of time after the Scanner Motor (M21) has been started.
* The same condition is detected after the error retry is performed.
Failure of the Scanner Motor (M21)
The speed lock signal indicates a deviation 10 times in sequence at intervals of 100 msec
0002
E110
after the signal has indicated a locked state.
* The same condition is detected after the error retry is performed.
Failure of the Scanner Motor (M21)
The scanner motor (M21) speed lock signal does not indicate a locked state for 6.5 sec.
0003 after a switchover is made from low to normal speed or for 8 sec. after a switchover is
made from normal to low speed.
* The same condition is detected after the error retry is performed.
Error in EEPROM access
E196 0000 20 retries failed after error occurred during communication with EEPROM.
* Error occurs after the delivery if a paper in passage exists.
0000

Error in communication of Laser Driver PCB (PCB14)


Communication error 1 with image PCB

0001

Error in communication of Laser Driver PCB (PCB14)


Communication error 2 with image PCB

E197

There is an error in the detection of the CIS home position.


E202 0000 1.The attempt to detect the home position fails when the CIS is moved forward.
2.The attempt to detect the home position fails when the CIS is moved back.
E225 0000

The light intensity of the CCD is faulty.


The light intensity of the CCD during shading is under the specified level.

The reader unit power supply (24V) is faulty.


1.At time of power-on, the 24V port is off.
E227 0000 2.At the start of a job, the 24V port is off.
3.At the end of a job, the 24V port is off.
4.When a load is being driven, the 24V port is off.
0000
E240

Error in controller communication


The serial communication error such as parity error or overrun error is constantly detected.

Error in controller communication


0001 The serial communication error such as parity error or overrun error is detected while
printing.

EEPROM error
1.An error has occurred at power-on.
E248 0000
2.An error has occurred during write operation.
3.An error has occurred during read operation following write operation.
Error in Zero Cross
E261 0000 Zero Cross failed to be detected for 500ms or more while the relay was ON.
* The same condition is detected after the error retry is performed.
E280 0000

Reading unit communication error


Reading error after writing.

Release Motor (M2) error


E413 0000 The sensing level of the release motor HP sensor (SR11) does not change within a
specified period when the release motor (M2) is driven.
E500 0000

Communication error
The communication with the host machine is interrupted.

E505 0001

E520

E531

E532

Shift Motor (M4) error


0001 The shift roller does not leave the shift roller home position when the Shift Motor (M4) has
been driven for 1.2 seconds.
Shift Motor (M4) error
0002 The shift roller does not return to the shift roller home position when the Shift Motor (M4)
has been driven for 1.2 seconds.
Stapler Motor (M10) error
8001 The stapler does not leave the staple home position when the Staple Motor (M10) has
been driven for 0.5 sec.
Stapler Motor (M10) error
8002 The stapler does not return to the staple home position when the Stapler Motor (M10) has
been driven for 0.5 sec.
STP Move Motor (M1) error
0001 The stapler does not leave the stapler move home position when the STP Move Motor
(M1) has been driven for 0.25 sec.
STP Move Motor (M1) error
0002 The stapler does not return to the stapler move home position when the STP Move Motor
(M1) has been driven for 2.8 sec.
0001

E540

E567

E571

E575

E602

Tray Lift Motor (M11) time out error


The stack tray does not move within a specified time period.

Tray Lift Motor (M11) closing detect switch error


0005 The FG input cannot be detected when the Tray Lift Motor (M11) has been driven for 0.1
second.
0001

E542

EEPROM error
The checksum for the EEPROM data has an error.

Additional Tray Lift Motor (M12) time out error


The stack tray does not move within a specified time period.

Additional Tray Lift Motor (M12) closing detect switch error


0005 The FG input cannot be detected when the Additional Tray Lift Motor (M12) has been
driven for 0.1 second.
Shift Roller Release Motor (M5) error
0001 The shift roller does not leave the shift roller release home position when the Shift Roller
Release Motor (M5) has been driven for 0.1 sec.
Shift Roller Release Motor (M5) error
0002 The shift roller does not return to the shift roller release home position when the Shift
Roller Release Motor (M5) has been driven for 0.06 sec.
Gripper Open/Close Motor (M7) error
0001 The gripper unit does not leave the gripper unit home position when the Gripper
Open/Close Motor (M7) has been driven for 0.25 seconds.
Gripper Open/Close Motor (M7) error
0002 The gripper unit does not return to the gripper unit home position when the Gripper
Open/Close Motor (M7) has been driven for 0.15 seconds.
Gripper Unit Move Motor (M2) error
0001 The gripper unit does not leave the gripper unit home position when the Gripper Unit Move
Motor (M2) has been driven for 3.8 seconds.
Gripper Unit Move Motor (M2) error
0002 The gripper unit does not return to the gripper unit home position when the Gripper Unit
Move Motor (M2) has been driven for 0.1 seconds.
0001 The built-in SD card is not detected
1105 Access to the built-in SD card failed

E711 0001

Error in UFDI communication


The communication system error (such as reception timeout or checksum error) occurred.

Erroneous communication with finisher


E713 0000 The communication does not restart by the error retry after the communication failure with
the finisher.

E716

Erroneous communication with optional cassette or 2-way unit


0000 After the presence of a cassette pedestal or a 2-way unit has been detected, the
communication fails to be normal for 5 sec.
Failure of the communication with the 2-way unit
0010 When the communication with the 2-way unit is faulty after detecting the connection with
the finisher.

E719 0000 Erroneous communication with New Card Reader (serial communication)
0002 Erroneous communication with Coin Vendor (serial communication)
E736 0000 Erroneous communication between CCU and controller.
0001 Mismatched version between the language file and the Bootable
E744

0002 Oversized language file in HDD


0003 Mismatched version between the language file and the Bootable
0004 Language file reading error

E804

Failure of the Power Supply Cooloing Fan (FAN6)


When lock signal is detected for 5 sec while the Power Supply Cooloing Fan (FAN6) is
0000
stopped.
* The same condition is detected after the error retry is performed.
Unstable rotation of the Power Supply Cooloing Fan (FAN6)
When lock signal failed to be detected for 5 sec while the Power Supply Cooloing Fan
0001
(FAN6) is driven.
* The same condition is detected after the error retry is performed.
Failure of the Exhaust Fan (Rear) (FAN3)
0000 When lock signal is detected for 5 sec while the Exhaust Fan (Rear) (FAN3) is stopped.
* The same condition is detected after the error retry is performed.

Unstable rotation of the Exhaust Fan (Rear) (FAN3) or Finisher Fan 1 (M8) or Finisher Fan
2 (M9)
1.When lock signal failed to be detected for 5 sec while the Exhaust Fan (Rear) (FAN3) is
0001 driven.
2.When lock signal failed to be detected for 5 sec while the Finisher Fan 1 (M8) is driven.
3.When lock signal failed to be detected for 5 sec while the Finisher Fan 2 (M9) is driven.
E805
* The same condition is detected after the error retry is performed.
Failure of the Exhaust Fan (Front) (FAN4)
0002 When lock signal is detected for 5 sec while the Exhaust Fan (Front) (FAN4) is stopped. *
The same condition is detected after the error retry is performed.
Unstable rotation of the Exhaust Fan (Front) (FAN4)
When lock signal failed to be detected for 5 sec while the Exhaust Fan (Front) (FAN4) is
0003
driven.
* The same condition is detected after the error retry is performed.

You might also like