You are on page 1of 9

Omnik Hybrid Inverter Introduction

Outline
Product Specification
Operating Principle
Battery Charger/Discharger
Hybrid Inverter Roadmap

Omnik I

Product Specification

Omnik I

Omnik and SolaX similarities


Specification

Omnikhyd-3k-TL2

SK-SU3000

Input / Output Power

3300W / 3000W

Power Factor

0.95i10.95c

Battery type

Lead-acid/Lithium battery

Charging curve

3-stage adaptive with maintenance

Depth of discharge

60% for lead-acid, 80% for lithium

Monitoring

RS-485 (WiFi, GPRS Optional)

Topology

Transformerless

Product Specification

Omnik I

Omnik and SolaX differences


Specification
Battery Capacity

Omnikhyd-3k-TL2
4.8kWh, 9.6kWh

SK-SU3000

Omnik Strength

4.8kWh only

More capacity storage


to achieve higher self
consume rate

Charge/Discharge Current

2500W

1300W

Charge battery faster


and provide bigger load
consumption

Efficiency

Max 98.3%

Max 97.6%

Higher efficiency to get


more harvest

Display

800*480 TFT color


display

Backlight 16*4
character

Easier operation and


friendly display

Degree of Protection

IP65

IP20

Longer lifetime and


lower failure rate

THD

<2%

3%

Better output quality

Operating Principle

Omnik I

Omnik hybrid PriorityLoad > Battery > Grid


Thanks to the external smart electricity meter, it calculates power that the household load
used and feedback information to hybrid inverter. Then the hybrid will feed corresponding
power to utility to enhance self use consumption. Self consumption rate will increased up
to 70%.
Morning: PV generated energy is used first
and foremost to optimize your own
consumption. Any surplus energy is used to
charge batteries.
Afternoon: When the batteries are fully
charged, the system provides energy for your
own consumption and any surplus is fed into
the public grid.
Evening: The system switches to battery
energy after sundown. Omnik Hybrid allows
you to produce 70% or more of your own
consumption.
Night: If the battery is exhaust, electricity is
obtained from the public grid.

Operating Principle

Omnik I

SolaX Hybrid Priority: Battery > Grid & Load


Without a external smart electricity meter, the hybrid can not distinguish household
load from utility grid. So when the sun rises, X-Hybrid charges battery first until battery
capacity is full. Then surplus PV power will convert to feed into utility grid. After the sun
goes down, X-Hybrid will supply battery power to grid and load even there is no load
consume. In this case the self consumption rate is only about 50%.

Battery Charger / Discharger

Omnikhyd-3k-TL2

Omnik I

SK-SU3000

Battery charger/discharger is
integrated in the hybrid inverter,
easier to wiring and installation.

Battery charger/discharger separated


from hybrid inverter, more difficult to
wiring and installation.

Charge/Discharge power up to 2500W,


battery can store more than 10kWh in
daytime, so house load can consume
up to 10kWh PV energy at night.

Charge/Discharge power only 1300W,


battery can store only 5kWh in
daytime, surplus PV energy feed into
utility grid. So the self consumption is
much lower.

Battery can supply bigger power to


larger load as air conditioner and
boiler.

Battery can supply only 1300W to


small bigger power to household
appliances such as lamp and laptop.

Connect to 10kWh capacity battery.

Connect to 5kWh capacity battery.

Hybrid Inverter Roadmap

Omnik I

More independent from utility grid in the future

With the external current measurement, the system will include controllable load
which can increase self consumption rate.

With additional electrical relay, hybrid inverter can auto switch on/off grid mode.

Omnik New Energy Co.,Ltd.