You are on page 1of 12

DISEO DE BOCATOMAS

Caudal de Captacin
Qd =
Caudal de Avenida de Diseo Qmax =
Caudal de estiaje
Q=
Pendiente Promedio
S=
Ancho del Rio en Zona de Capt. B =
Coeficiente de Manning
n=

0.48 m3/s
20 m3/s
0.523 m3/s
0.059 m/m
7.5 m
0.093

1.- CALCULO HIDRAULICO PARA CONDICIONES CRTICAS:


DATOS:

Qdis =
S=
n=
B=

20
0.059
0.093
7.5

m3/s
m/m
m

q = Q/B

Asumimos que es una seccin rectangular.


Caudal por unidad de ancho.

q = 2.6666666667 m3/s*m

Yc = (q^2/g)^(1/3)

Tirante Crtico

Yc = 0.8983029359 m

Ac = B*Yc
Ac =

rea Crtica
6.7372720189 m2

P = B +2*Yc
P=

Perimetro crtico
9.2966058717 m

Rc = Ac/Pc
Rc =

Radio Crtico
0.7247023389 m

Vc = Qdis/Ac
Vc =

Velocidad Crtica

2.9685605604 m/s

Sc = (Qdis*n/(Ac*Rc^(2/3)))^2
Sc =

0.1170877623

Ec = 3/2*Yc
Ec =

Energia Crtica
1.3474544038

F = Vc/(G*Yc)^(1/2)
F=

2.- CALCULO HIDRAULICO PARA CONDICIONES NORMALES:


DATOS:

Qaveni =
S=
n=
B=

20 m3/s
0.059 m/m
0.093
7.5 m

K' = Q*n/(B^(8/3)*S^(1/2))
k' =

Y/B =
y=

Curva para determinar la profundidad cuadro 6.6


0.0355295933 Con este valor acudimos al grafico 6.6 para seccion rectangular.
0.14993 Este valor es del cuadro 6.6.
1.1245

A = B *Y
A=

rea Normal
8.4335625

P = B +2*Y
P=

Perimetro Normal
9.74895

R = A/P
R=

Radio hidraulico
0.865073931

V = Qaven/A
V=

Velocidad normal

2.3714770597

F = Vc/(G*Yc)^(1/2)
F=

0.7140185948

1
flujo sub crtico.
Si es falso es super Crtico.

DISEO HIDRAULICO DE LA ESTRUCTURA DE BARRAJE:


1.- ALTURA DE LA CARGA EN LA CRESTA DE BARRAJE:
La altura de barraje se considera para efectos del calculo del caso mas Crtico.

Se utiliza calculando con la formula siguiente.


DATOS :

Yn =

1.1245

Q = C*L*Ho^1.5
Donde:

Q=
20
Caudal Maximo
C=
1.9895857143
Coeficiente de Descarga
L=
7.5
Longitud de Rio
Ho =
1.216
Haltura de sobre carga Maxima sobre la cresta
Debemos Asumir P Y Ho en funcion al Caudal tiene que ser igual
P=
1.4
Ho =
1.216

C = (3.27 + 0.40*Ho/P)*0.55
C = 1.9895857143
Q = 20.0089491134 m3/s

20 Los asumido estan correctos


debe cumplir que los caudales
sean iguales

q = Q/L
q=

2.6666666667 m3/s*m

V = q/(P+Ho)
V=

Velocidad

1.0193679918

La altura maxima de acuerdo a las maxima avenida es:

Y max = P + Ho
Y max =

2.616 m

2.- CALCULO DE LA LONGITUD DEL ALIVIADERO Y DE LA COMPUERTA DE LIMPIA

DATOS:

Se recomienda que:
Lr =

7.5

Ac = Ab/10

donde:

Lc = Lr/11

donde:

Lc =

Ac = rea de la compuerta
Ab = rea del aliviadero
Lr =
Lc =

Longitud del Rio.


Longitud de la compuerta movil.

e=

espesor del pilar

0.68 m

e = Lc /4
e=
Lf = Lr - Lc - e
Lf =

0.2
6.65 m

3.- DISEO DEL BARRAJE DE ACUERDO A LAS LONGITUDES RECOMENDABLES:

El caso mas desfavorable, se presenta cuando ocurre la maxima avenida y la compuerta de limpia se encuentra cerrada, entonces el analisis de hace
para los acasos siguientes:
3.1.- CUANDO LA COMPUERTA DE LIMPIA SE ENCUENTRA CERRADA:
DATOS:

Qmax =
Le =
P=
Ho =

20 m3/s
6.65 m
1.40
1.26 Asumimos Ho

Q = C*Le*Ho^1.5
C = Co*K1*K2*K3*K4
1 Tomando en cuenta la profundidad de llegada:

P/Ho.Co

1.11464968 Del cual

2 Por efecto de las cargas diferentes:

Ho/HeC/CoK1

Ho =He

del cual

3 Por efecto del talud del paramento de aguas arriba:

K2
4 Por efecto de interferencia del lavadero aguas abajo

(Hd + d)/Ho = (p +Ho)/Ho..K3

2.11464968

5 Efectos de Sumergencia:

Hd/Ho.K4

C = Co*K1*K2*K3*K4
C=

3.889

Q = C*Le*Ho^1.5
Q = 20.0151240293

20 Debe ser igual al caudal de diseo

3.2.- CUANDO LA COMPUERTA DE LIMPIA SE ENCUENTRA ABIERTA:


ESTO ES PARA EL ALIVIADERO:
DATOS:
P=
Ho =
Caso 1:
Caso 2:
Caso 3:
Caso 4:
caso 5:

1.40
1.1 asumir

P/Ho
1.2727272727
K1 =
1
K2 =
1
2.2727272727
K3 =
K4 =
1

del cuadro

Co =

3.904

C = Co*K1*K2*K3*K4
C=

3.904

Q = C*Le*Ho^1.5
Q = 16.4677672487
ESTO ES PARA LA LIMPIA
DATOS:
P=
1.40
Ho =
2.50
caso 1 =
0
Caso 2:
K1 =
Caso 3:
K2 =
Caso 4:
1 K3 =
caso 5:
K4 =

Co =

3.088

Del cuadro obtenemos

1
1
0.77
1

C = Co*K1*K2*K3*K4
C=

2.37776

Q = C*Le*Ho^1.5
Q=

3.5245956231

Q max =

19.992362872 =

Altura de Muro de Encauzamiento

H muro = P + HoCrtico + hl
H muro =

2.82 m

4.- DISEO DEL COLCHON DISIPADOR


DATOS DE DISEO:

Q max =
Ho =
P=
L=
Yn =

20 m3/s
1.216
1.40
7.50
1.1245

20 debe concordar con el caudal e avenida

q =Q/L
q = 2.6666666667

Aguas arriba del aliviadero.

Vo = q/(P+Ho)
Vo = 1.0193679918

hv = Vo^2/(2*g)
hv = 0.0529618299
Por lo tanto.
ho = 1.1630381701
***Aplicando Ec de Energia entre seccin entre (0) y ( 1)

Eo = E11
Z + P + Ho = Y1 + V1^2/(2*g) + hf(0-1)
hf(0-1) = K*V1^2/(2*g)
hf(0-1) =
0.00510 *V1^2
V1 = Q/(B*Y1)
V1 =
3.00854701
Y1
hf(0-1) =
0.04613331
Y1^2
Z=
Y1 +
0.507
Y1^2

2.62 ..(A)

*** Aplicando el tirante conjugado entre (1) y (2)

Y2 = - Y1/2 + (Y1^2/4 + 2*Y1*V1^2/g)^0.5


Por lo tanto:

Y2 = Z + Yn
Yn =

Z= -

1.1245

Y1/2 +

(Y1^2/4 +

1.8453 )^0.5 Y1

1.1245 (B)

Igualando (A) y (B)


Y1 =

Z1
0.12 32.744721673
0.14 23.415142454
0.16 17.366905941
0.18 13.226542966
0.2 10.270659802
0.22 8.0888428119
0.24 6.4341804183
0.26 5.1508992913
0.28 4.1367856135
0.3 3.3225154677
0.32 2.6597264853

Z2
2.7374339048
2.436756919
2.1925423819
1.9886400939
1.8147126669
1.6637959069
1.531004189
1.4127955257
1.3065311502
1.2101995829
1.1222371861

Y1 =

Z1
0.34 2.11384768
0.36 1.65963574
0.38 1.27831019
0.4 0.95566495
0.42 0.68079361
0.44 0.4452107
0.46 0.24223437
0.48 0.0665451
0.5 -0.0861344
0.52 -0.2192752
0.54 -0.3357174

Z2
1.0414077119
0.9667192128
0.8973653476
0.8326830464
0.7721214057
0.7152184541
0.6615835389
0.6108837938
0.562833615
0.5171863864
0.473727907

Y1 =

0.422 Del cuadro para Y1


Reemplazando en (A) se tiene:

Z(A) =
0.7
q = Q/L
3.0085470085
V1 =q/Y1
7.1292583141
F1 = V1/(9.81*Y1)^0.5
F1 =
3.5039154788

Cuando el numero de FROUDE esta entre 2.5 y 4.5 no se forma un verdader


hidraulico, los lechos amortiguadores para este tipo de regimen no producen
disipacin efectiva debido a que el oleaje propagado por el flujo oscilante, no
amortiguarse completamente y sale fuera del colchon

El tirante conjugado ser por seguridad


Y'2 = 10% Y2
Y'2 = 1,1 *Y2
L1/Y2 = 5.80
Y2 = Yn + z
Y2 =
Y'2 =

segn BUREAU OF RECLAMATION


1.7801
1.9580715404

Reemplazando en la ecuacion
L1 =

11.356814934

didad cuadro 6.6

errada, entonces el analisis de hace

Co =

3.889

K1 =

K2 =

K3 =

1
k4 =
de los cuadros
obtenemos todos los
k

(B)

Z2
1.0414077119
0.9667192128
0.8973653476
0.8326830464
0.7721214057
0.7152184541
0.6615835389
0.6108837938
0.562833615
0.5171863864
0.473727907

e 2.5 y 4.5 no se forma un verdadero resalto


este tipo de regimen no producen una
propagado por el flujo oscilante, no puede
del colchon