Allen Bradley

Adjustable
Frequency AC Drive

Powerflex 4M
400 W

AB Powerflex 4M

Wiring the Drive

AB Powerflex 4M

I/O Wiring Examples

AB Powerflex 4M

I/O Wiring Examples

AB Powerflex 4M

I/O Wiring Examples

AB Powerflex 4M

I/O Wiring Examples

AB Powerflex 4M

I/O Wiring Examples

AB Powerflex 4M

Parameter Organization

AB Powerflex 4M

Parameter Organization - Display


d001 Output Frequency

Output frequency present at T1, T2 & T3 (U, V & W).

d002 Commanded Frequency

Value of the active frequency command. Displays the


commanded frequency even if the drive is not running.

d003 - Output Current

The output current present at T1, T2 & T3 (U, V & W).

d004 - Output Voltage


d006 Drive Status

Present operating condition of the


drive.

The output voltage present at T1, T2 & T3 (U, V & W).

d005 DC Bus Voltage

Present DC bus voltage level.

AB Powerflex 4M

Parameter Organization
d010 Process Display

The output frequency scaled by A440 [Process Factor] or by A438 [Process Time Lo] and
A439 [Process Time Hi].

d012 Control Source

Displays the active source of the Start


Command and Speed Command.

AB Powerflex 4M

Parameter Organization
d012 Control In Status

Status of the control terminal block control inputs.


Important: Actual control commands may come from a source other than the control
terminal block.

d018 - Elapsed Run Time

Accumulated time drive is outputting power. Time is displayed in 10-hour increments.

AB Powerflex 4M

Parameter Organization
d020 - Analog In 0-10V

The present value of the voltage at I/O Terminal 13 (100.0% = 10 volts).

d021 - Analog In 4-20mA

The present value of the current at I/O Terminal 15 (0.0% = 4mA, 100.0% = 20mA).

d022 - Drive Temperature

Present operating temperature of the drive power section.

AB Powerflex 4M

Parameter Organization - Program


P101 Motor NP Voltage

Stop drive before changing this parameter.


Set to the motor nameplate rated voltage.

P102 Motor NP Hertz

Stop drive before changing this parameter.


Set to the motor nameplate rated frequency.

P103 Motor OL Current

Set to the maximum allowable motor current.

P104 Minimum Frequency

Sets the lowest frequency the drive will output


continuously. Min/Max: 0.0/400.0 Hz

P105 Maximum Frequency

Sets the highest frequency the drive will output


continuously. Min/Max: 0.0/400.0 Hz

AB Powerflex 4M

Parameter Organization - Program


P106 Start Source

Stop drive before changing this parameter.


Sets the control scheme used to start the drive.

P107 Stop Mode

Active stop mode for all stop sources


0Ramp, CF(1) (Default)
Ramp to Stop. Stop command clears
active fault.
1Coast, CF(1)
Coast to Stop. Stop command clears
active fault.

AB Powerflex 4M

Parameter Organization - Program


P108 Speed Reference

Sets the source of the speed reference to the drive.

P109 Acc. time

Sets the rate of acceleration for all speed increases.

AB Powerflex 4M

Parameter Organization - Program


P110 Dec. Time

Sets the rate of deceleration for all speed decreases.

P112 Reset to Default

Resets all parameter values to factory defaults.

AB Powerflex 4M

Parameter Organization - Terminal


t201 Digital In1 Sel
(I/O Terminal 5)
T202 Digital In2 Sel
(I/O Terminal 6)

AB Powerflex 4M

Parameter Organization - Terminal


t201 Digital In1 Sel
(I/O Terminal 5)
T202 Digital In2 Sel
(I/O Terminal 6)

AB Powerflex 4M

Parameter Organization - Terminal


t211 Analog In 0 ~ 10 V Lo

Sets the analog input level that corresponds to P104 [Minimum Freq] if a 010V input is used by P108
Analog inversion can be accomplished by setting this value larger than
t212 [Anlg In 0-10V Hi] or by setting t201 - t202 [Digital Inx Sel] to option
15 Anlg Invert.

t212 Analog In 0 ~ 10 V Hi

Sets the analog input level that corresponds to P105 [Maximum Freq] if a 0-10V input is
used by P108 [Speed Reference].
Analog inversion can be accomplished by setting this value smaller than t211 [Anlg In 010V Lo] or by setting t201 - t202 [Digital Inx Sel] to option 15 Anlg Invert.

AB Powerflex 4M

Parameter Organization - Terminal


t213 Analog In 4 ~ 20mA Lo

Sets the analog input level that corresponds to P104 [Minimum Freq] if a 420mA input is used by P108 [Speed Reference].
Analog inversion can be accomplished by setting this value larger than t214
[Anlg In4-20mA Hi] or by setting t201 - t202 [Digital Inx Sel] to option 15
Anlg Invert.

t214 Analog In 4 ~ 20mA Hi

Sets the analog input level that corresponds to P105 [Maximum Freq] if a 420mA input is used by P108 [Speed Reference].
Analog inversion can be accomplished by setting this value smaller than
t213 [Anlg In4-20mA Lo] or by setting t201 - t202 [Digital Inx Sel] to option
15 Anlg Invert.

AB Powerflex 4M

Parameter Organization - Terminal


t221 Relay Out Selection

Sets the condition that changes the state of the output relay contacts.

AB Powerflex 4M

Parameter Organization - Terminal


t221 Relay Out Selection

Sets the condition that changes the state of the output relay contacts.

t222 Relay Out Level

Sets the trip point for the digital output relay if the value
of t221 [Relay Out Sel] is 6, 7, 8, 10 or 11.

100+ Video Tutorials

Coupon Code

in $99 $49

https://www.udemy.com/nfi-plc-online-leaning/?couponCode=slideshare

Life time Access


Course Outline

Learn to Code | Code to Learn

nfi
Learn 4 PLCs in a Day
presents

PLC Programmable Logic Controller


Delta DVP 14 SS + 16 SP
100+ PLC Video Tutorials
Allen Bradley M1000
Doubt Clearing Complementary LIVE Sessions on Team Viewer
Siemens S7 200
Ladder Logic Programming
Schneider
PLC Presentations, PLC Circuits, PLC Codes
Analog Cards Programming
FREE PLC Simulation Software for Practice
04 AD Analog to Digital
04DA- Digital to Analog
For more courses visit www.nfiautomation.org

PLC & VFD Advanced


Course

4 PLCs Training
Platforms

$149
Course Link:

Course Highlights: http://www.wiziq.com/course/28882-plc-andac-drives-online-certificate-trainaing-course

30 Live Practical Classes on PLC, Analog Cards & AC drives- VFD


100+ PLC Video Tutorials with Lifetime Access & FREE PLC Simulator
FREE Circuits Diagram

For more courses visit www.nfiautomation.org

Thanks
www.nfiautomation.org

nfi

You might also like