St-52.

STRUCTURAL STEEL

St-52.3

EQUIVALENCES BETWEEN DIFFERENT DESIGNATIONS


Designation

Other designations

According to 1)
EN 10025-2:2004

EN 10025:1990+A1:1993

Symbolic

Numeric

Symbolic

Numeric

S355J2+N

1.0577+N

S355J2G4

1.0577

EN 10025:1990

Germany
DIN 17100

ASTM (96)

Fe510D2

(St-52.3N)

A570 Grado50

The chemical composition of the steels named between brackets has a slight difference from the standard named in
EN 10025-2:2004.

CHEMICAL COMPOSITION
Analysis on the casting
Maximum content (%)
Nominal diameter of the product (mm)

>1640

16

C
0,20

Nominal diameter of the product (mm)

>40100

>3040

30

>40150

1)

Ceq

0,20

0,22

0,45

0,47

>150250 >250400

Si

Mn

0,55

1,60

0,025

0,025

2)

0,47

0,49

0,49

1) For the nominal diameter> 100 mm the content of C will be establishd by agreement.
2) It is calculated according to the formula.

Ceq = C +

Mn
6

Cr+Mo+V
5

Ni+Cu

15

Analisis on the product


Maximum content (%)
Nominal diameter of the product (mm)
>1640

16

>40100

Si

Mn

0,24

0,60

1,70

0,035

0,035

1)

C
0,23

0,23

1) For the nominal diameter> 100 mm the content of C will be establishd by agreement.

MECHANICAL CHARACTERISTICS
Tencile test

Elongation limit1)

Tencile endurance

Nominal diameter (mm)


<16

>16
40

>40
63

>63
80

>80
100

>100
150

Nominal diameter (mm)


>150
200

>200
250

>250
400

<3

345

335

>100
150

3
100

Rp0,2 (MPa)
355

1)

>150
250

>250
400

450
600

450
600

Rm (MPa)

325 315 295

285

275

265

510
680

470
630

450
600

Enlargement 1)
L0=80 mm
Nominal diameter (mm)

Test tube
direction

>1
1,5

>1,5
2

>2
2,5

L0=5d
Nominal diameter (mm)
>2,5
3

3
40

>40
63

>63
100

>100
150

>150
250

>250
400

21

20

18

17

17

A (%)
Longitudinal

14

15

16

17

18

22

1) The given values in this table are applicable for longitudinal test tubes. For test tubes of 600 mm it is used a transverse test tube.

These records are intended solely for informative purposes. The conditions on the material supply are based on the real characteristics of manufacturing and the quality certificate of the same.

St-52.3
STRUCTURAL STEEL

MECHANICAL CHARACTERISTICS (continuation)


Shock bending test

1)

2) (mm)
Nominal diameter

12> d 150

150 > d 250

250 > d 400

Absorved energy (Julios)


27

27

27

1) Test made on a testing tube of KV at 20C.


2) For profiles and dimension bars of >100 mm the flexion test will be performed at request

PERMANENT STOCK
Profile

Round

Gap
between

Scale
(mm)

measurements

25-140

140-150

150-330

10

340-400

10

425-650

25

Supply status
Material

Surface
Lamination
gross

Without treatment
Standardized

Bright turned/
lamination gross
Wrought iron
gross

Endurance of Endurante to
diameter (mm) cuts (mm)

Maximum
arrow
(mm/m)

10

10

*The superficial defects of the gross worght iron materials might be of a 2% diameter and in the lamination gross materials of 1%.

PROPERTIES
It has good cold weldability, bending and deformation conditions. It does not accept
hardening. It has a good resistance to low temperature impacts previews to the standard treatment.

USES
Mechanical elements of middle responsibility. It does not have an elevated level of resistance
but it does have a good toughness.
This steel is used in mechanical structures with high responsibility and mechanical
pieces such as bolts, fixation elements, washers, iron works, etc.

P.I. Ali-Gobeo Alibarra, 24 Pab.1 01010 Vitoria-Gasteiz Tel.: 902 10 38 99 Fax: 945 21 39 68 ipargama@ipargama.com