Selection of Elevator System

The selection of elevators should be made in consideration of the building type/scale, tenant
characteristics, elevator usage and the anticipated passenger carrying capacity at the
building s traffic peak time.
Hyundai elevators are available from hydraulic elevators to low-medium and high-speed
traction elevators, covering the full range of vertical transportation requirements.
And a variety of functional and attractive designs per usages, such as passenger, service,
observation, hospital bed, freight and automobile elevators are offered for architects and
customers flexible applications.

ELEVATORS

Speed

Operation

60

1 Car : Selective Collective


2 Cars : Duplex Selective Collective

Kinds of Building

Usage

Control

Low-Rise Apartment
Low-Rise Building

Passenger
Observation
Hospital

Gearless(*include MRL)

Mid-Rise Apartment
Mid-Rise Building

Passenger
Observation
Hospital

Gearless(*include MRL)

60 ~ 150

Geared

60, 90, 105

High-Rise Apartment
High-Rise Building

Passenger

Gearless

180 ~ 1080

General Traction

30, 45

Parking Building

Automobile
Hydraulic

20, 30, 45

General Traction

30, 45, 60

Hydraulic

20, 30, 45

(m/min)

MOVING WALKS

ESCALATORS

Contents
Selection Of Elevator System

04
06
08
10

Factory, Warehouse

Single Automatic

Single Automatic
1 Car : Selective Collective
2 Cars : Duplex Selective Collective

Freight

Note : The table shows the common method of elevator system selection per usages.

18
20

Code Application of Elevator Models

F/

21
22

Capacity
(Persons/kgs)

23
24
29
30

32
33
34
35
36
37

Speed

No. of lnstall. Floors

(m/min)

(Including Non-Stop Floors)

Usage
MRL
MP
MS
MPF
MOB
MB
MF
MA

General Traction
P
S
(PF)
OB
B
F
A

Note : MRL(Machine-Room-Less)

1 Car : Selective Collective


2 Cars : Duplex Selective Collective
3-8 Cars : Group Supervisory

12
14
16

Escalators / Moving Walks Layout Plan


1. Millennium Escalators(30)
2. Millennium Escalators(35)
3. H-Series Escalators
4. Modular Escalators
5. Moving Walks
6. Electric Power Requirements (By others)

3-8 Cars : Group Supervisory

03

Elevators Layout Plan


1. Passanger Elevators
Gearless Elevators 60~150m/min
Machine-Room-Less Elevators 60~105m/min
Geared Elevators 60~105m/min
2. High-Speed/Ultra-High-Speed Elevators
3. Observation Elevators
Gearless & Geared Elevators(1, 2side Type) 60~105m/min
Gearless & Geared Elevators(3side, Semicircle Type) 60~105m/min
Machine-Room-Less Elevators(1, 2side Type) 60~105m/min
4. Freight Elevators
General Type (2S, 2U, 3U)
Hydraulic Type (2S, 2U, 3U)
5. Automobile Elevators
General Type (2U, 3U)
Hydraulic Type (2U, 3U)
6. Hospital Bed Elevators
General Type (2S, 2SD)
7. Typical Entrance Layouts
8. Works To Be Done By Other Contractors
9. Electric Power Requirements (By others)

Geared

Hydraulic
HP
HS
(HPF)
HOB
HB
HF
HA

ST
No. of Stop
Floors

Door Opening Type


Type
Passenger
Service
(Passenger & Freight)
Observation
Hospital Bed
Freight
Automobile

Single
Double
Entrance Entrance
CO
COD
2S
2SD
2CO
2COD
2U
2UD
3S
3SD
3U
3UD

Type
2-Panel Center Opening
2-Panel Side Opening
4-Panel Center Opening
2-Panel Up-Sliding
3-Panel Side Opening
3-Panel Up-Sliding

PASSENGER ELEVATORS
Gearless Elevators 60~150m/min

Plan of Hoistway & Machine Room

Section of Hoistway

Standard Dimensions & Reactions

MX1

Speed
(m/min)

X1
A

CB

M/C Room
Height(MH)

Vent Fan(By others)

R2
Control
Panel

Ent. Height (EH)

Vent Fan(By others)


Y

CB

Vent Grille(By others)

Beam (By others)

Vent Grille(By others)

OP

OP

R2

R2
Control
Panel

R3
Receptacle
(By others)

Distribution Board
(By others)

External

1Car

M/C Room
2Cars 3Cars Depth Reaction(kg)

X2

X3

MX1

MX2

MX3

MY

R1

R2

850 1460 1005 1800

3700

5600

1430

2000

4000

6000

3200

3600

2000

800

1400 1030 1460 1185 1800

3700

5600

1610

2000

4000

6000

3400

4050

2250

600

800

1400 1130 1460 1285 1800

3700

5600

1710

2000

4000

6000

3500

4100

2450

10

700

800

1400 1250 1460 1405 1800

3700

5600

1830

2000

4000

6000

3600

4200

2700

11

750

800

1400 1350 1460 1505 1800

3700

5600

1930

2000

4000

6000

3700

4550

2800

13

900

900

1600 1350 1660 1505 2050

4200

6350

1980

2300

4400

6800

3750

5100

3750

15

1000

900

1600 1500 1660 1655 2050

4200

6350

2130

2300

4400

6800

3850

5450

4300

17

1150

1000

1800 1500 1900 1670 2350

4800

7250

2180

2600

4900

7500

3900

1100

2000 1350 2100 1520 2550

5200

7850

2030

2800

5250

8300

3800

6600

5100

20

1350

1000

1800 1700 1900 1870 2350

4800

7250

2380

2600

4900

7500

4200

1100

2000 1500 2100 1670 2550

5200

7850

2180

2800

5250

8300

4000

7800

6000

24

1600

2000 1750 2100 1920 2550

5200

7850

2430

2900

5400

8300

4300

2150 1600 2250 1770 2700

5500

8300

2280

3000

5650

8700

4200

8500

6800

kg

OP

CA

450

800

1400

550

1100

CB

X1

2Cars 3Cars Depth 1Car

Ladder
(By others)

R4
Waterproof Finish
(By others)

(Unit : mm)

Machine Room Access Door(By others)


Min. 900(W) 2000(H)

MX3
X3

R1

R1

Speed
(m/min)

Overhead
(OH)

Pit
(PP)

M/C Room Height


(MH)

60

4600

1500

2200

90

4800

1800

2400

105

5000

2100

2400

120

5000

2100

2600

150

5500

2400

2600

Note : Machine room temperature should be maintained below 40C


with ventilating fan and/or air conditioner (if necessary) and
humidity below 90%.

B
Y

CB

Beam
(By
others)
Beam
Beam
(By
(By
others)
others)
Beam
Beam(By
(Byothers)
others)
Beam
Beam
(By
(By
others)
others)

Vent Fan (By others)


Min.100

X2

OP

OP

OP

R2

R2

R2

Control
Panel

Control Control
Panel
Panel
Distribution Board
(By others)

MY

CA

Vent Fan (By others)

Vent Grille(By others)

Internal

M/C Room

Pit Depth (PP)

MY

CA

Hoistway

Car

Notes : 1. Above hoistway dimensions are based on 15-storied buildings. For application to over 16-storied buildings,
the hoistway dimensions shall be at least 5% larger considering the sloping of the hoistways.
2. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
3. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
4. The capacity in persons is calculated at 65kg/person. (EN81=75kg/person)
5. Above dimensions are applied in case the door is standard. In case fire protection door is applied, hoistway size for 1 car
should be applied above X1 dimension plus 100mm.
6. In case of 120m/min and 150m/min, the dimension of X1 is X1 plus 100mm.

2100

Total Height (TH)

A
R1

150

Clear
Opening

Persons

Machine Room Access Door(By others)


Min. 900(W) 2000(H)

X2

Vent Grille(By others)

90

120

X1
R1

X1
A
R1

60

105

MX2

Control
Panel

R1

Overhead (OH)

OP

Distribution Board
(By others)

Cinder
Concrete Min. 150
(By others)

R2

MY

CA

Suspension Hook
(By others)

Travel (TR)

Vent
Grille(By
others)
Vent
Grille(By
others)
Vent
VentGrille(By
Grille(Byothers)
others)
Vent
Grille(By
others)

R1

Capacity

(Unit : mm)

Machine Room Access Door(By others)


Min. 900(W) 2000(H)

PASSENGER ELEVATORS
Machine-Room-Less Elevators 60~105m/min

Plan of Hoistway & Machine Room (8~17 Person)

Section of Hoistway
Lighting(By others)

Lighting(By others)

Hook(By others)

X
A
R3

R1

Over Head(OH)

Top floor
(By others)

R4

R2

OP

without

control

panel

Travel(TR)

Total Height(TH)

Floor

Entrance Height(EH)

CB

CA

Traction
Machine

Control
Control
Control
Control
Control
Control
Panel
Panel
Panel
Panel
Panel
CP
530

Floor

Ladder
(By others)

with

control

Car
Hoistway
Clear
Motor
Speed Capacity Opening
Internal External 1 Car Depth
(kW)
(m/min)
Persons kg
OP
CA CB
A B
X
Y
60
90
105
60
90
105
60
90
105
60
90
105
60
90
105
60
90
105
60
90
105

3.4
5.1
5.9
3.7
2050 1800 5.6
6.5
4.3
2050 1800 6.5
7.5
4.6
2050 1850 6.9
8.1
5.6
2300 1800
8.3
2200 1850
9.7
6.2
1900
2300
9.2
(2100)
10.8
7.1
2600 2100 10.6
12.4

550

800

1300 1100 1360 1255 2050 1700

600

800

1300 1190 1360 1345

10

700

800

1300 1300 1360 1455

11

750

800

1300 1400 1360 1555

13

900

900

1600 1300 1660 1455


1500 1400 1560 1555

15

1000

900

1600 1400 1660 1555

17

1150

1000

1800 1400 1900 1570

(Unit : mm)
Notes : 1. The dimension in ( ) is for the heavy car weight such as the car floor using
finished granite.
2. When non-standard capacities and dimensions (including fire protection doors) are
required to meet the local code, please consult Hyundai.
3. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
4. The capacity in persons is calculated at 65kg/person. (EN81=75kg/person)
5. If the height of floor is over 11m, please consult Hyundai as to the needs for emergency
exit
6. Above dimensions are applied to standard door only. In case fire protection door is
applied, hoistway size for 1 car should be applied above X1 dimensions plus 100mm
and over.

Receptacle
(By others)

OP

Standard Dimensions (20, 24 Person)

panel

Lighting
(By others)

Notes : 1. The lighting of hoistway should be installed less than


500mm from above the ceiling of hoistway and within
500mm above the bottom of the pit. (By others)
2. Machine room temperature should be maintained
below 40C with ventilating fan and/or air conditioner
(if necessary) and humidity below 90%.

Pit Depth(PP)

Distribution Board
(By others)

Standard Dimensions (8~17 Person)

Waterproof Finish
(By others)
R5

R6

Car
Hoistway
Clear
Motor
Speed Capacity Opening
Internal External 1 Car Depth
(kW)
(m/min)
Persons kg
OP
CA CB
A B
X
Y
60
90
105
60
90
105

20

24

8.3
1350 1000 1800 1600 1900 1770 2625 2400 12.5
14.5
9.9
1600 1100 2000 1700 2100 1870 2825 2450 14.8
17.2

(Unit : mm)
Notes : 1. When non-standard capacities and dimensions are required to meet the local
code, please consult Hyundai.
2. The minimum hoistway dimensions are shown on the above table.
Therefore, some allowances should be made considering the sloping of the
hoistways.
3. Consult Hyundai if the emergency stop device is installed on the counterweight.

Plan of Hoistway & Machine Room (20, 24 Person)


(Unit : mm)

X
Min.225

Min.500

Persons
Distribution Board
(By others)

Top floor
(*)

R3
CA
R1

OP

(*)

CB

R2

Floor

R4
Top floor
(By others)

Floor

8~17

Control
Control
Control
Control
Control
Control
Panel
Panel
Panel
Panel
Panel
CP

OP

without

control

panel

with

control

20, 24
panel

Speed
(m/min)

Overhead
(OH)

Pit
(PP)

60
90
105
60
90
105

3800
3900
4000
4200
4350
4450

1500
1800
2100
1500
1800
2100

Control panel
(CP)(*)

Reactions

530

Persons
530
630
630

Notes : 1. Above dimensions are applied for car height of 2500mm (car internal height is
2300mm). For other applicable dimensions, consult Hyundai.
2. For car internal height (under 17 persons) of 2500mm, dimension of overhead is
OH plus 200mm.
3. If the dimension between the wall of hoistway and car external dimensions (A, B)
is in excess of over 850mm, the dimension of overhead is OH plus 200mm.
4. The minimum hoistway dimensions are shown on the above table. Therefore,
some allowances should be made considering the sloping of the hoistways.
5. When face to face arrangement is required, partitioning work for hoistway is
required. (EN81)
6. If the hoistway is glass, consult Hyundai as it needs to finish joining glass. (EN81)
7. The lighting should be installed at the top and bottom of hoistway.

(Unit : mm)

M/C Room Reaction(kg)

Pit Reaction(kg)
R5

R1

R2

R3

R4

8~17

8000 3500 1500 3000

20, 24

14000 3800 1500 4500

R6

Speed
(m/min)

Speed
(m/min)

Under 60 10000 Under 60 8000


90.105 14000 90.105 12000
Under 60 12000 Under 60 9500
90.105

21500

90.105

17500

Notes : 1. The minimum dimensions for the standard are shown on the above table.
Consult Hyundai in case of non-standard.
2. Consult Hyundai if the hoistway is steel structure.

PASSENGER ELEVATORS
Geared Elevators 60~105m/min

Plan of Hoistway & Machine Room

Section of Hoistway

MX1

Vent
Grille(By
others)
Vent
Grille(By
others)
Vent
Grille(By
others)
Vent
Grille(By
others)
Vent
Grille(By
others)
Vent
Grille(By
others)

Cinder
Concrete Min. 150
(By others)

Overhead (OH)

Vent Fan(By others)

MY

CA

OP
R2

MX2

MX3

MY

R1

R2

850 1460 1005 1800

3700

5600

1430

2000

4000

6000

3200

3600

2000

800

1400 1030 1460 1185 1800

3700

5600

1610

2000

4000

6000

3400

4050

2250

600

800

1400 1130 1460 1285 1800

3700

5600

1710

2000

4000

6000

3500

4100

2450

10

700

800

1400 1250 1460 1405 1800

3700

5600

1830

2000

4000

6000

3600

4200

2700

11

750

800

1400 1350 1460 1505 1800

3700

5600

1930

2000

4000

6000

3700

4550

2800

13

900

900

1600 1350 1660 1505 2050

4200

6350

1980

2300

4400

6800

3750

5100

3750

15

1000

900

1600 1500 1660 1655 2050

4200

6350

2130

2300

4400

6800

3850

5450

4300

17

1150

1000

1800 1500 1900 1670 2350

4800

7250

2180

2600

4900

7500

3900

1100

2000 1350 2100 1520 2550

5200

7850

2030

2800

5250

8300

3800

6600

5100

20

1350

1000

1800 1700 1900 1870 2350

4800

7250

2380

2600

4900

7500

4200

1100

2000 1500 2100 1670 2550

5200

7850

2180

2800

5250

8300

4000

7800

6000

24

1600

2000 1750 2100 1920 2550

5200

7850

2430

2900

5400

8300

4300

2150 1600 2250 1770 2700

5500

8300

2280

3000

5650

8700

4200

8500

6800

450

800

1400

550

Ladder
(By others)

MX2

(Unit : mm)

Beam
(By others)

Speed
(m/min)

Overhead
(OH)

Pit
(PP)

M/C Room Height


(MH)

60

4600

1500

2200

90

4800

1800

2400

105

5000

2100

2400

Note : The minimum hoistway dimensions are shown on the above table.
Therefore, some allowances should be made considering the sloping of the hoistways.

CA

R2

R2
Control
Panel

Control
Panel

Distribution Board
(By others)

Machine Room Access Door(By others)


Min. 900(W) 2000(H)

OP
OP
OP
OP
OP
OP

OP
OP
OP
OP
OP
OP

OP
OP
OP
OP
OP
OP

R2

R2

R2

Control
Panel

Control
Panel

Control
Panel
Distribution Board
(By others)

Vent Fan(By others)

OP
Vent Grille(By others)

OP

MY

MY

CA

R1

R1

Vent Grille(By others)

A
R1

CB

Vent Fan(By others)


Min. 100

X1

R1

CB

R1

X2
Vent Fan(By others)

Vent Grille(By others)

Waterproof Finish
(By others)

X3

X1

Beam (By others)

Vent Grille(By others)

MX3

X2

1100

CB

X1

M/C Room
2Cars 3Cars Depth Reaction(kg)

Notes : 1. Above hoistway dimensions are based on 15-storied buildings. For application to over 16-storied buildings,
the hoistway dimensions shall be at least 5% larger considering the sloping of the hoistways.
2. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
3. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
4. The capacity in persons is calculated at 65kg/person. (EN81=75kg/person)
5. Above dimensions are applied in case the door is standard. In case fire protection door is applied, hoistway size for 1 car
should be applied above X1 dimension plus 100mm.

2100

Ent. Height (EH)


Receptacle
(By others)

2Cars 3Cars Depth 1Car


MX1

105

Pit Depth (PP)

Note : Machine room temperature should be maintained below 40C


with ventilating fan and/or air conditioner (if necessary) and
humidity below 90%.

1Car

Travel (TR)

Total Height (TH)

Machine Room Access Door(By others)


Min. 900(W) 2000(H)

External

M/C Room

X3

CA

90

Hoistway

X2

OP

Control
Panel

Distribution Board
(By others)

Internal

kg

60

(Unit : mm)

Car

Persons

R1

R2

CB

A
R1

Clear
Opening

Capacity

Speed
(m/min)

Suspension Hook
(By others)

M/C Room
Height(MH)

X1

Standard Dimensions & Reactions

Machine Room Access Door(By others)


Min. 900(W) 2000(H)

HIGH-SPEED/ULTRA-HIGH-SPEED ELEVATORS
Gearless Elevators 180~600m/min

Plan of Hoistway & Machine Room (In-Line Arrangement of 3 Units)

Section of Hoistway

Standard Dimensions & Reactions

Hook or Trolly Beam


(By others)

R2

R2

R2

R2

Control Panel

Distribution Board (By others)

Note : Temperature should be maintained below 40C and humidity


below 90%, with installation of a ventilating fan, ventilating grille,
and air conditioner (if necessary). Toxic gas or dust should not be generated.

OP

13

900

900

15

1000

900

17

1150

1000
1100

20

1350

1000

24

1600

15

1000

1100

900
1000

Entrance
Height

Machine Room Access Door (By others)


900(W) X 2000(H)

kg

1100

Travel(TR)

R2

Persons

180

Total Height(TH)

OP

Vent Fan (By others)

OP

MY

CA

OP

R1

Clear
Opening

Capacity

2100

CB

R1

Overhead(OH)

R1

R1
Beam
(By others)

Vent Grille (By others)

Vent Grille (By others)

B Vent Fan (By others)


Min. 200
Y

X2
X1
A
R1

Suspension
Cinder Concrete
Min. 150
(By others)

M/C Room
Height
(MH)

MX3
X3

Speed
(m/min)

17

1150

20

1350

Pit Depth(PP)

210

Receptacle
(By others)

240

1000
1100
1000
1100

Ladder
(By others)

Waterproof Finish
(By others)

24

1600

20

1350

1100

Face-to-Face Arrangement
1000
MX3
X3

300

X2

R1

R1
Beam
(By others)
CB

B
CA
MY

OP

Min. 200

OP

C P
C P

X1

Vent Grille (By others)

R2

Vent Grille (By others)

OP

R2
C P
C P

Distribution Board
(By others)
Y
3600 ~ 4000
MY

OP

Vent Fan
(By others)

OP
R2

Machine Room
Access Door
(By others)
900(W) X 2000(H)

CA

420
480
540
600

Vent Fan (By others)

MX2
X2

R1
Beam
(By others)

C P
C P

Vent Grille (By others)

Vent Fan (By others)

R1

CB

Vent Grille (By others)

R1

Min. 200

360

X1
A

OP

1100

OP

24

1600

1100

17
20
24

1150
1350
1600

1000
1100
1100

(Unit : mm)

Car
Internal
CA CB
1600
1600
1600
1600
1800
2000
1800
1800
2000
2000
2000
2000
2150
2150
1600
1600
1800
1800
1800
2000
1800
1800
2000
2000
2000
2000
2150
2150
1800
1800
2000
2000
2000
2000
2150
2150
1800
2000
2000

1350
1400
1500
1550
1500
1350
1700
1730
1500
1550
1750
1800
1600
1670
1500
1550
1300
1370
1500
1350
1700
1730
1500
1550
1750
1800
1600
1670
1700
1730
1500
1550
1750
1800
1600
1670
1500
1500
1750

External
A B
1700
1700
1700
1700
1900
2100
1900
1900
2100
2100
2100
2100
2250
2250
1700
1700
1900
1900
1900
2100
1900
1900
2100
2100
2100
2100
2250
2250
1900
1900
2100
2100
2100
2100
2250
2250

1570
1620
1720
1770
1720
1570
1920
1950
1720
1770
1970
2020
1820
1890
1720
1770
1520
1590
1720
1570
1920
1950
1720
1770
1970
2020
1820
1890
1920
1950
1720
1770
1970
2020
1820
1890

1Car
X1
2300
2300
2300
2300
2500
2700
2500
2500
2700
2700
2700
2700
2850
2850

Hoistway
2Cars 3Cars Depth 1Car
X2
X3
Y
MX1

M/C Room
M/C Room
2Cars 3Cars Depth Reaction(kg)
R1
R2
MX2 MX3 MY

4550
4550
4550
4550
4950
5350
4950
4950
5350
5350
5350
5350
5650
5650
4600
4600
5000
5000
5000
5400
5000
5000
5400
5400
5400
5400
5700
5700
5100
5100
5500
5500
5500
5500
5800
5800

5500
5500
5500
5500
6100
6250
6100
6100
6250
6250
6250
6250
6500
6500
5600
5600
5800
5800
6100
6200
6100
6100
6200
6200
6400
6400
6500
6500
6200
6200
6200
6200
6500
6500
6500
6500

6900
6900
6900
6900
7500
8100
7500
7500
8100
8100
8100
8100
8550
8550
6950
6950
7550
7550
7550
8150
7550
7550
8150
8150
8150
8150
8650
8650
7700
7700
8300
8300
8300
8300
8750
8750
7800
8750
8750

2200
2250
2350
2400
2400
2250
2600
2630
2400
2450
2650
2700
2500
2570
2400
2450
2200
2300
2400
2250
2600
2650
2400
2450
2650
2700
2500
2600
2650
2700
2450
2500
2650
2700
2500
2600
2500
2500
2750

2800
2800
2800
2800
3000
3200
3000
3000
3200
3200
3200
3200
3400
3400

7900
7900
7900
7900
8800
9100
8900
8900
9100
9100
9100
9100
9400
9500
8200
8200
8400
8400
8900
9000
8800
8800
9000
9000
9000
9000
9400
9400
9100
9100
9100
9100
9100
9100
9400
9400
8900
9500
9500

4500
4500
4700
4700
4700
4500
5000
5000
4700
4700
5000
5000
4900
4900
4900
4900
4900
4900
4900
4900
5000
5000
5000
5000
5000
5000
5000
5000
6000
6300
5900
6300
6300
6300
6200
6300
6000
6300
6300

12030

6630

12810 6950
13080 7130

14360 7650

15090 8080

12810 7800

14100 8000

15100 8050

15700 8100

17800 13200

18100 13500

Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some allowances should be made considering the sloping of the hoistways.
2. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
3. For elevators with more than 28 persons capacity, consult Hyundai.
4. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
5. The capacity in persons is calculated at 68kg/person. (EN81=75kg/person)
6. Above dimensions are applied in case the door is standard. In case fire protection door is applied, hoistway size for 1 car should be applied above X1 dimension plus 100mm.
7. The maximum speed capabilities of Hyundai is 1080m/min. Consult Hyundai.

OP

R2

R2
Control
Panel

(Unit : mm)

Control
Panel
Distribution Board (By others)

Machine Room Access Door (By others)


900(W) X 2000(H)

Speed
(m/min)

Overhead
(OH)

Top Clearance
(TC)

Pit
(PP)

M/C Room
Height (MH)

Speed
(m/min)

Overhead
(OH)

Top Clearance
(TC)

Pit
(PP)

M/C Room
Height (MH)

180
210
240
300
360

6000
6400
7100
8000
8300

2300
2700
3350
4000
4000

2700
3200
3850
4200
4300

2500
2800
2800
3000
3000

420
480
540
600

8500
9500
9750
10000

4200
5700
5950
6200

6000
6400
8800
9000

3200
3500
3500
3500

Notes : 1.The above table shows minimum figures. Therefore, some allowances should be made considering errors that may occur during construction.
2. Above dimensions are applied in case car height is 2800mm. In case car height is over 2800mm, overhead should be applied above dimension plus additional height.

10

11

OBSERVATION ELEVATORS
Gearless & Geared Elevators 60~105m/min

Plan of Hoistway & Machine Room

Section of Hoistway

Standard Dimensions & Reactions


Type

MX

Glass Enclosure(By others)


Min.
500

2-Side
Observation

Pit Depth (PP)

Note : Machine room temperature should be maintained below 40C


with ventilating fan and/or air conditioner (if necessary) and
humidity below 90%.

Maintenance Deck
(By others)
Receptacle
(By others)

800

1400

850

1460 1060

2200 1400

2600 2900

3750

2600

550

800

1400 1030

1460 1240

2200 1500

2600 3000

4200

2800

600

800

1400 1130

1460 1340

2200 1600

2600 3100

4300

2900

10

700

800

1400 1250

1460 1460

2200 1750

2600 3200

4450

3050

11

750

800

1400 1350

1460 1560

2200 1850

2600 3350

4600

3150

13

900

900

1600 1350

1660 1560

2400 1850

3000 3350

5200

3950

15

1000

900

1600 1500

1660 1710

2400 2000

3000 3500

5500

4450

17

1150

1000

1800 1500

1900 1710

2850 2000

3500 3500

7550

5500

20

1350

1000

1800 1700

1900 1910

2850 2200

3500 3700

8200

6200

24

1600

1100

2000 1750

2100 1960

3050 2250

3700 3750

8800

6950

550

800

1400 1030

1460 1240

2200 1500

2600 3000

4200

2800

600

800

1400 1130

1460 1340

2200 1600

2600 3100

4300

2900

10

700

800

1400 1250

1460 1460

2200 1750

2600 3200

4500

3100

60

11

750

800

1400 1350

1460 1560

2200 1850

2600 3350

4700

3300

90

13

900

900

1600 1350

1660 1560

2400 1850

3000 3350

5350

4050

105

15

1000

900

1600 1500

1660 1710

2400 2000

3000 3500

5650

4600

Type

17

1150

1000

1800 1500

1900 1710

2850 2000

3500 3500

7700

5650

20

1350

1000

1800 1700

1900 1910

2850 2200

3500 3700

8350

6300

24

1600

1100

2000 1750

2100 1960

3050 2250

3700 3750

9000

7050

90

Waterproof Finish
(By others)

External
A B

Hoistway
X

M/C Room
MX

MY

Control
Panel
Distribution Board
(By others)

Vent Grille(By others)

R2

OP

(Unit : mm)

Machine Room
Access Door(By others)
Min. 900(W) 2100(H)

Vent Fan(By others)

MY

CB

R1

Y
B

A
Glass Wall
(By others)

CA

Ladder
(By others)

60

Internal
CA CB

Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors. Consult Hyundai.
2. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
3. The capacity in persons is calculated at 65kg/person. (EN81=75kg/person)
4. Above dimensions are applied in case the door is standard. In case fire protection door is applied, hoistway size for 1 car
should be applied above X1 dimension plus 100mm.

MX

12

450

105

Concrete(Min. 3600) or
Glass Enclosure
(By others)

Travel (TR)

Total Height (TH)

Distribution Board
(By others)

2100

Control
Panel

2Side

kg

Cinder
Concrete Min. 150
(By others)

1-Side
Observation

M/C Room
Reaction(kg)
R1
R2

Persons

Capacity

Suspension Hook
(By others)

Ent. Height (EH)

M/C Room
Height(MH)
Vent Grille(By others)

CB

OP

Machine Room
Access Door(By others)
Min. 900(W) 2100(H)

Vent Fan(By others)

CA

MY

R2

R1

Y
B

A
Glass Wall
(By others)

Car

Clear
Opening
OP

Speed
(m/min)

Type

Overhead (OH)

1Side

(Unit : mm)

Speed
(m/min)

Overhead
(OH)

Pit
(PP)

M/C Room Height


(MH)

60

4700

1700

2200

90

4900

1800

2400

105

5000

2100

2400

Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
2. The minimum machine room height should be 2800mm in case of the traction
machine with double isolation pad.

13

OBSERVATION ELEVATORS
Gearless & Geared Elevators 60~105m/min

Overhead
(OH)

Pit
(PP)

M/C Room Height


(MH)

60

4800

1800

2200

90

5000

2050

2400

105

5100

2050

60
90
105

Persons

kg

Clear
Opening
OP

Receptacle
(By others)

Ladder
(By others)

11
13
15
17
20
24

750
900
1000
1150
1350
1600

800
900
900
1000
1000
1100

(Unit : mm)

Car

1400
1600
1600
1800
1800
1800

1400
1450
1570
1580
1800
2000

1460
1660
1660
1900
1900
1900

1610
1660
1780
1790
2010
2210

M/C Room
Height(MH)
B
Y

Overhead
(OH)

Pit
(PP)

M/C Room Height


(MH)

60

4800

1800

2200

90

5000

2050

2400

105

5100

2050

2400

Glass Enclosure(By others)

Total Height (TH)

2100

Ent. Height(EH)

Vent Grille(By others)


S

Speed
(m/min)

Travel (TR)

Min.
500

Maintenance
Deck
(By others)
Receptacle
(By others)

Ladder
(By others)

Waterproof Finish
(By others)

Note : Machine room temperature should be maintained


below 40C with ventilating fan and/or air conditioner
(if necessary) and humidity below 90%.

Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
2. The minimum machine room height should be 2800mm in case of the traction
machine with double isolation pad.
3. Above dimentions are changeable according to the car exterior design.

1Car
X1

Hoistway
2Cars Depth
Y
X2

2450
2650
2650
2850
2850
2850

5100
5500
5500
6100
6100
6100

2000
2050
2200
2200
2400
2600

1Car
MX1

1200
1350
1350
1600
1600
1600

2900
3300
3300
3500
3500
3500

Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
2. Consult Hyundai if the capacity is 10 persons and less.

14

(Unit : mm)

Note : Machine room temperature should be maintained


below 40C with ventilating fan and/or air conditioner
(if necessary) and humidity below 90%.

External
A B

R2

Vent Grille(By others)

Waterproof Finish
(By others)

2400

Internal
CA CB

Machine Room Access Door(By others)


Min. 900(W) 2100(H)

Type

Maintenance Deck
(By others)

Standard Dimensions & Reactions


Capacity

Distribution Board
(By others)

Semicircle

Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
2. The minimum machine room height should be 2800mm in case of the traction
machine with double isolation pad.
3. Above dimentions are changeable according to the car exterior design.

Speed
(m/min)

Control
Panel

Pit Depth (PP)

Total Height (TH)

Min.
500

Cinder
Concrete Min. 150
(By others)

OP

Control
Panel

(Unit : mm)

Speed
(m/min)

CA

OP

Machine Room Access Door(By others)


Min. 900(W) 2100(H)

Type

550

Glass Enclosure(By others)

Pit Depth (PP)

3Side

Vent Fan(By others)

Distribution Board
(By others)

Cinder
Concrete Min.150
(By others)

Travel (TR)

Vent Fan(By others)

Vent Fan(By others)

Control
Panel

200

CB

M/C Room
Height(MH)
Overhead (OH)

MY
OP

Control
Panel

B
R1 S

Vent Grille(By others)

CB

R2

Vent Grille(By others)

CA

OP

550

550

Vent Fan(By others)

Glass Enclosure(By others)

200

Concrete(Min. 3600) or
Glass Enclosure
(By others)

A
Glass Enclosure
(By others)

Suspension Hook
(By others)

X2, MX2

Suspension Hook
(By others)

Ent. Height(EH)
2100

550

Section of Hoistway

Overhead (OH)

X2, MX2

Plan of Hoistway & Machine Room

Concrete(Min. 3600) or
Glass Enclosure
(By others)

Section of Hoistway

MY

Plan of Hoistway & Machine Room

M/C Room
2Cars Depth
MX2
MY
5100
5500
5500
6100
6100
6100

3500
3550
3700
3700
3900
4100

M/C Room
Reaction(kg)
R1
R2
4900
5500
5750
8200
8500
9600

3500
4050
4700
6400
6600
7500

Standard Dimensions & Reactions


Speed
(m/min)

60
90
105

Persons

kg

Clear
Opening
OP

11
13
15
17
20
24

750
900
1000
1150
1350
1600

800
900
900
1000
1000
1100

Capacity

(Unit : mm)

1Car
X1

Hoistway
2Cars Depth
Y
X2

2450
2650
2650
2850
2850
2850

5100
5500
5500
6100
6100
6100

Car
Internal
CA CB
1400
1600
1600
1800
1800
1800

1480
1500
1650
1650
1900
2130

External
A B
1460
1660
1660
1900
1900
1900

1690
1710
1860
1860
2110
2340

2000
2050
2200
2200
2400
2600

1Car
MX1

1200
1350
1350
1600
1600
1600

2900
3300
3300
3500
3500
3500

M/C Room
2Cars Depth
MY
MX2
5100
5500
5500
6100
6100
6100

3500
3550
3700
3700
3900
4100

M/C Room
Reaction(kg)
R1
R2
5150
5700
5950
8200
8950
9600

3950
4500
4950
6400
6950
7500

Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
2. Consult Hyundai if the capacity is 10 persons and less.

15

Control panel
CP

FREIGHT ELEVATORS
General Type (2S, 2U, 3U)

Plan of Hoistway & Machine Room

Section of Hoistway

Standard Dimensions & Reactions

MX

Model

X
A

M/C Room
Height(MH)

Vent Grille(By others)

Vent Fan
(By others)

F0750-2S

Cinder
Concrete Min. 150
(By others)

F1000-2S

Machine Room
Access Door(By others)
Min. 900(W) 2000(H)

CA

OP

F1500-2S

Overhead (OH)

MY

R2

CB

R1

Suspension Hook
(By others)

Entrance
Speed
Door
(m/min) Opening Width Height Entrance
Type
(OP EH)
Type

F2000-2S

Distribution Board(By others)

SIDE-OPENING

DOORS

Total Height (TH)

2-PANEL

F2000-2U

(2S)

Travel (TR)

Note : Temperatures should be maintained below 40C with ventilating


fan and/or air conditioner (if necessary) and humidity below 90%.

F2500-2S

F3000-2U

2S

30
45
60

2S

30
45
60

2S

30
45
60

2S

30
45
(60)

2S

45

Pit Depth (PP)

Wall+Finished

OP

50

50

Min. 300

Min. 650

2-PANEL

UP-SLIDING

DOORS

Receptacle
(By others)

(2U)

F3500-2U

Ladder
(By others)

R3

R4

Waterproof Finish
(By others)

F4000-3U

Minimum floor height : Opening height 3 / 2 + 700mm


Minimum entrance height : 2100mm
F5000-3U

30
45
25
30
25
30

CA CB

A B

1400 2100

Double
Entrance

2U

1700 2100

1700 2100

2300 2100

1800 2100

2500 2100

Double
Entrance

2700 2300

2800 2500

3000 2800

2400 3076 3300 3450

3200 3000

2400 2898 3300 3250

Double
Entrance

2400 3016 3300 3490

Standard

2600 3228 3500 3600

Double
Entrance

2600 3376 3500 3750

4800 2800 3200

6200

4100

5000

4300

4800 3200 3500

8500

5700

7100

6100

4800 3600 4000 10800

7100

9000

7500

4800 3800 4200 13300

8800

11400

9400

4600 3800 4200 13300

8800

11400

9400

4800 4000 4400 15100

10000

13200 10700

4600 4000 4400 15100

10000

13200 10700

4800 4200 4800 15200

10100

13500 10500

5000 4300 5200 21700

14500

19000 15500

5300 4500 5900 32500

21700

28700 23700

5500 4700 6400 36000

23000

31700 26700

2500 3000

Standard

2600 3198 3500 3600

Double
Entrance

2600 3316 3500 3800

Double
Entrance

R4

2300 2700

Standard

2800 3498 3700 3900


2700 3300
2800 3616 3700 4100
3020 3998 4050 4400
2800 3800
3020 4116 4050 4600
3220 4758 4250 5250
3000 4500
3220 4936 4250 5520
3420 5258 4450 5750

Standard
3U

R3

2200 2876 3000 3250

Double
Entrance

Double
Entrance

R2

2200 2728 3000 3050


2100 2500

Standard
3U

R1

1950 2226 2750 2600

2400 2928 3300 3250

Double
Entrance

Buffer
Reaction (kg)

1950 2078 2750 2400


1850 1850

Standard
2U

M/C Room
Reaction (kg)

1800 1989 2500 2320

Standard

Double
Entrance

M/C Room
Overhead (MX MY)
(OH)

1800 1857 2500 2150

Standard
2U

X Y

1700 1650

Standard

2U

30

Double
Entrance

Hoistway
External

Standard

30
45
60

30
45
(60)

Car
Internal

Standard
1100 2100

200

30

Ent. Height(EH)

F2500-2U

30
45
60

(Unit : mm)

3200 5000
3420 5436 4450 6020

Wall+Finished

250

30

Notes : 1. Please consult Hyundai when the loading capacity is over 5000kg or the car is non-standard size.
2. The loading capacity should be over 250kg/m2 minimally.
3. The actual reaction may slightly differ from above dimensions in line with machine beam position.

OP

50

(Unit : mm)

50

Min. 650

Min. 300

4-PANEL
3-PANEL

UP-SLIDING

DOORS

(3U)

Minimum floor height : Opening height 4 / 3 + 750mm


Minimum entrance height : 2100mm
Note : Consult Hyundai if the dimensions are less than the minimum.

18

CENTER

OPENING

DOORS

Speed
(m/min)

Pit
(PP)

M/C Room Height


(MH)

30, 45

1250

2400

60

1500

2600

(2CO)

Notes : 1. Above is minimum size.


2. Refer to standard dimensions & reactions for overhead height.

19

FREIGHT ELEVATORS

AUTOMOBILE ELEVATORS

Hydraulic Type (2S, 2U, 3U)

General Type (2U, 3U)

Section of Hoistway
Suspension Hook(By others)

Section of Hoistway

Min. 650
600

Suspension Hook
(By others)
Cinder
Concrete Min.150
(By others)

200
200 30
200
200
Waterproof Finish
(By others)

Receptacle
(By others)

3-PANEL

UP-SLIDING

DOORS

2-PANEL

SIDE-OPENING

DOORS

(2S)

Minimum floor height : Opening Height X 4/3+750mm


Minimum entrance height : 2100mm

Control
Panel

2100

4100

Travel(TR)

2000

20m

Notes : 1. Temperatures should be maintained below 40C with


ventilating fan and/or air conditioner (if necessary) and
humidity below 90%.
2. The above are minimum size.
3. The overhead height can be varied in line with entrance height
and door type.
4. Consult Hyundai if the travel height is 20m or more.

Standard Dimensions & Reactions

(Unit : mm)

Car

Entrance
Height
EH

Internal
CA CB

External
A B

Model

Speed
(m/min)

Clear
Opening
OP

X Y

MX MY

HF1500-2U

20/30/45

2100

2100

2100 2500

2200 2698

3050 3100

2500 2800

4200

400

HF2000-2U

20/30/45

2300

2100

2300 2700

2400 2898

3250 3300

2500 2800

4800

400

HF2500-2U

20/30/45

2500

2100

2500 3000

2600 3198

3450 3600

2500 2800

5400

400

HF3000-2U

20/30/45

2700

2300

2700 3300

2800 3498

3650 3900

2500 2800

6000

450

HF3500-2U

20/30

2800

2500

2800 3800

2900 3998

4000 4450

2800 3200

7900

750

HF4000-3U

20/30

3000

2800

3000 4500

3100 4758

4200 5250

2800 4200

8800

900

HF5000-3U

20/30

3200

3000

3200 5000

3300 5258

4400 5750

2800 4200

10500

1050

Hoistway

Notes : 1. Please consult Hyundai when the loading capacity is over 5000kg or the car is non-standard size.
2. The loading capacity should be over 250kg/m2 minimally.
3. The actual reaction may slightly differ from above dimensions in line with machine beam position.
4. Above dimensions are based on up-sliding door available for 2-panel side-opening(2S) doors of same capacity.

20

Travel (TR)
Ent. Height(EH)
1800
Pit Depth(PP)

Waterproof Finish
(By others)

250

M/C Room
Height (MH)

1400

Ladder
(By others)

(Unit : mm)
(Unit : mm)

20, 30, 45

Receptacle
(By others)

Distribution Board (By others)

Notes : 1. Consult Hyundai if the actual size is less than the above minimum floor height.
2. The left and right minimum size should be 650mm and 300mm respectively for the
installation of driving part.

Speed(m/min) Ent. Height(EH) Overhead(OH) Pit(PP)

Notes : 1. Temperatures should be


maintained below 40C with
ventilating fan and/or
air conditioner (if necessary)
and humidity below 90%.
2.The specification of car doors
are optional.

Vent
Fan(By
others)
Vent
Fan(By
others)
Vent
VentFan(By
Fan(Byothers)
others)
Vent
Fan(By
others)
Vent
Fan(By
others)

R1

OP

(3U)

(2U)

R2

25
130
50
Min. 300

DOORS

Vent Grille (By others)

30

OP

UP-SLIDING

MX

250
Wall+Finished

50
Min. 650

Overhead (OH)

R1

Travel(TR)

Ladder
(By others)

Min. 300

Minimum floor height : Opening height 3 / 2 + 700mm


Minimum entrance height : 1800mm

(2U)

Minimum floor height : Opening Height 3/2+700mm


Minimum entrance height : 2100mm

50

30

DOORS

2-PANEL

OP

M/C Room

Hitch Beam
Reaction (kg)
R1
R2

Speed
(m/min)
30, 45

Overhead
(OH)
4400

Pit
(PP)

Wall+Finished

UP-SLIDING

50
Min. 650

MY

2-PANEL

Total Height(TH)

50

OP

50

Power Unit

Machine
Room
Machine
Room
Machine
MachineRoom
Room
Machine
Room
Machine
Room
Access
Door(By
others)
AccessDoor(By
Door(Byothers)
others)
Access
Access
Door(By
others)
Access
Door(By
others)
Min.
900(W)
2000(H)
2000(H)
Min.900(W)
900(W) 2000(H)
Min.
Min.
900(W)
2000(H)
Min.
900(W)
2000(H)

MX

CA

Ent. Height(EH)

200 30

Vent Grille
(By others)

Machine Room
Access Door
[By others]
Min
Min
Min 900(W) 2000(H)
Min
Min
Min

Control
panel

Pit Depth(PP)

CB

Power Unit

MY

(Hydraulic hose)

R2

Distribution Board
[By others]

R2

R1

OPB

Vent Fan(By others)

CA

CB

Overhead(OH)

M/C Room
Height(MH)

X
A

Min. 300

Plan of Hoistway & Machine Room

Total Height (TH)

Plan of Hoistway & Machine Room

M/C Room Height


(MH)

1200

2400

50

3-PANEL

OP

UP-SLIDING

50

DOORS

(3U)

Minimum floor height : Opening height 4 / 3 + 750mm


Minimum entrance height : 1800mm

Note : The above are minimum size.


Note : Consult Hyundai if the dimensions are less than the minimum.

Standard Dimensions & Reactions


Type

Standard
Type

Double
Entrance
Type

Model

Speed
(m/min)

A2000-2U
A2500-2U
A2000-3U
A2500-3U
A2000-2UD
A2500-2UD
A2000-3UD
A2500-3UD

30, 45
30, 45
30, 45
30, 45
30, 45
30, 45
30, 45
30, 45

Clear
Opening
OP
2350
2750
2350
2750
2350
2750
2350
2750

(Unit : mm)

Car
Internal
CA CB
2350
2750
2350
2750
2350
2750
2350
2750

5300
6300
5300
6300
5300
6300
5300
6300

External
B
A
2450
2850
2450
2850
2450
2850
2450
2850

5350
6350
5350
6350
5300
6300
5300
6300

Hoistway

M/C Room

M/C Room
Reaction(kg)

MX

MY

R1

R2

3300
3700
3300
3700
3300
3700
3300
3700

5800
6800
5800
6800
5800
6800
5800
6800

3300
3850
3300
3850
3300
3850
3300
3850

5800
6800
5800
6800
5800
6800
5800
6800

17500
22500
17500
22500
17500
22500
17500
22500

12000
12500
12000
12500
12000
12500
12000
12500

Notes : 1. The car external size can be varied in line with entrance type.
2. When non-standard capacities and dimensions are required, consult Hyundai.
3. The car door is applied in BS code region.

21

AUTOMOBILE ELEVATORS

HOSPITAL BED ELEVATORS

Hydraulic Type (2U, 3U)

General Type (2S, 2SD)

Plan of Hoistway & Machine Room

Section of Hoistway

Plan of Hoistway & Machine Room


MX

X
Suspension Hook
(By others)

Min. 550

Suspension Hook(By others)


M/C Room
Height(MH)

300

Section of Hoistway

Overhead (OH)

CB

Vent Fan(By others)

Vent Grille (By others)

R1

CA

MY

200 30

Vent Grille
(By others)

Cinder Concrete
Min. 150
(By others)

R2

Control
panel

Machine Room
Access Door(By others)
Min. 900(W) 2000(H)

CB

Power Unit

Total Height (TH)

(Hydraulic hose)

MY

R2

R1
R1
R1
R1
R1

Distribution Board
(By others)

OPB

Vent Fan(By others)

Travel (TR)

CA

Overhead (OH)

MX
OP

Notes : 1. Temperatures should be maintained below 40C with ventilating fan and/or air conditioner
(if necessary) and humidity below 90%.
2. The specification of car doors is optional.

Travel (TR)

OP

Pit Depth (PP)

Minimum floor height : Opening height 3 / 2 + 700mm


Minimum entrance height : 1800mm

Power Unit

Control
Panel
Distribution Board
(By others)

Waterproof Finish
(By others)

Ladder
(By others)
Receptacle
(By others)

Ent. Height(EH)
2100

(2U)

Machine Room Access Door(By others)


900(W) 2000(H)

30

Pit Depth(PP)

DOORS

Total Height (TH)

UP-SLIDING

1800

2-PANEL

50
Ent. Height(EH)

50

250

(Unit : mm)
(Unit : mm)

Wall+Finished

50

OP

Speed
(m/min)

50

Min. 650

Min. 300

20, 30, 45
3-PANEL

UP-SLIDING

DOORS

(3U)

Overhead
(OH)

Pit
(PP)

3600

M/C Room Height


(MH)

1200

2000

Travel
(TR)
20m

Notes : 1. The above are minimum size.


2. Consult Hyundai if the travel height is 20m or more.
3. Consult Hyundai if the dimensions are less than the minimum.

Minimum floor height : Opening height 4 / 3 + 750mm


Minimum entrance height : 1800mm

Speed
(m/min)

Overhead
(OH)

Pit
(PP)

30, 45

4400

1200

60

4600

1500

90

4800

1800

105

5000

2100

M/C Room Height


(MH)

Receptacle
(By others)

2200

Ladder
(By others)

Waterproof Finish
(By others)

Notes : 1. Temperature should be maintained below 40C with


ventilating fan and/or air conditioner, if necessary, and
humidity below 90%.
2. In case of special hoistway, machine room height may be
higher than above size.
3. Above is minimum size.

2400

Standard Dimensions & Reactions


Standard Dimensions & Reactions
Type

Standard
Type

Double
Entrance
Type

Model

Speed
(m/min)

HA2000-2U
HA2500-2U
HA2000-3U
HA2500-3U
HA2000-2UD
HA2500-2UD
HA2000-3UD
HA2500-3UD

20,30,45
20,30,45
20,30,45
20,30,45
20,30,45
20,30,45
20,30,45
20,30,45

Clear
Opening
OP
2350
2750
2350
2750
2350
2750
2350
2750

(Unit : mm)

Car
Internal
CB
CA
2350
2750
2350
2750
2350
2750
2350
2750

5300
6300
5300
6300
5300
6300
5300
6300

Notes : 1. The car external size can be varied in line with entrance type.
2. When non-standard capacities and dimensions are required, consult Hyundai.

22

Type
External
B
A
2450
2850
2450
2850
2450
2850
2450
2850

5350
6350
5350
6350
5300
6300
5300
6300

Hoistway

M/C Room

Model

M/C Room
Reaction(kg)

MX

MY

R1

R2

3300
3700
3300
3700
3300
3700
3300
3700

5800
6800
5800
6800
5800
6800
5900
6900

2500
2500
2500
2500
2500
2500
2500
2500

2800
2800
2800
2800
2800
2800
2800
2800

5500
6400
5500
6400
5500
6400
5500
6400

250
300
250
300
250
300
250
300

B750-2S
Standard
Type
B1000-2S

Double
Entrance
Type

B750-2SD
B1000-2SD

Speed
(m/min)
30, 45
60
30, 45
60
30, 45
60
30, 45
60

Clear
Opening
OP

(Unit : mm)

Car
Internal
CA
CB

External
A
B

Hoistway
X

M/C Room
MX

MY

1100

1300 2300

1360 2492

2050 2850

2300 3500

1200

1500 2500

1560 2692

2300 3050

2750 4000

1100

1300 2300

1360 2634

2050 3000

2300 3500

1200

1500 2500

1560 2834

2450 3200

2750 4000

M/C Room
Reaction(kg)
R1

R2

5790

3450

5900

3750

6500

3700

6800

4100

5790

3450

5900

3700

9300

3700

9500

4100

Notes : 1. When non-standard capacities and dimensions are required, consult Hyundai.
2. Above dimensions are applied to standard door only. In case fire protection door is applied, hoistway size for 1 car should be applied above X dimension plus 100mm.

23

TYPICAL ENTRANCE LAYOUTS


Basic/Optional

Only for Floor with Control Panel of the Machine-Room-Less Elevators

Entrance

Structural Opening of Entrance


In

Entrance Design
case

man

Boxless
s

Type

Buttons

Structural Opening of Entrance

and

OF CAR

Switch

30

Fire

of

700

700

500
700

Jamb Height(JH)

Concrete Opening : 2200

30

Concrete Opening

200

500

250

700

1900

700

80
700

6 (By others)
EA

Steel Bar for


Fixing Jamb

300

700
700

Concrete Opening
Clear Opening
+ CP + 100
2

Clear
Opening
Clear
Opening
ClearOpening
Opening
Clear
Opening
Clear
Opening
Clear
Opening
+100
222222

700

(Optional)

CP210

1900
Concrete Opening

1000

1000

Type

Persons

Speed(m/min)

Width of
Control Panel(CP)(*)

8~17

Under 105

530

OP+300

Finished Floor Level


(By others)

Type

(Optional)

(Unit : mm)

20, 24

Type

Finished
Floor Level
(By others)

CP210

700

Concrete Opening:JH+50

1650
OP+300

700

700

Concrete Opening

150

9 6EA(By others)

80
Clear
Clear
Clear
Clear
Clear
Clear
Opening
Opening
(OP)
(OP)
Opening
Opening(OP)
(OP)
Opening
(OP)
Opening
(OP)

9 6EA (By others)

30

Wiring Inlet : 50
(By others)

Steel Bar for


Fixing Jamb

250
300

150

700

Concrete Opening:JH+50

Entrance Height (EH) : 2100

Jamb Height (JH)

700

9 6EA(By others)

Emergency
Call Switch

24

Clear Opening (OP)

(*)

Hall Position
Indicator

JP200

Hall Button

Concrete Opening : JH+50

Finished Floor Level


(By others)

Jamb Height(JH)

Concrete Opening
OP+300

Entrance Height(EH) : 2100

Steel Bar for Fixing Jambs

Transom Panel

30

(Standard)

OF CAR

1000

1650

300

1000

700

Concrete
Opening
OP+300

Steel Bar for


Fixing Jamb

CP

HB

Type

Position
Indicator

700

700

9 6EA(By others)

(Optional)

(For emergency
call, only rescue
floor is applied)

CP110

Transom Panel

30

Type

(Standard)

(By others)

Steel Bar for


Fixing Jamb

Finished
Floor Level
(By others)
JP100

Type

150

700

Concrete Opening : 2200

Jamb Height (JH)

Entrance Height (EH) : 2100

Clear
Clear
Clear
Clear
Clear
Clear
Opening
Opening
(OP)
(OP)
Opening(OP)
(OP)
Opening
Opening
Opening
(OP)
(OP)

30

Clear Opening
+ 100
2

Wiring Inlet : 50

(For emergency call, only


rescue floor is applied)

HB

Clear Opening
+ CP + 100
2

500
CP110

Concrete Opening : 2200

30

Emergency
Call Switch

200

Finished Floor Level


(By others)

Indicator

1000

Clear Opening (OP)

CP
(*)

Finished Floor Level


(By others)

Concrete Opening
OP+140

(Basic)

1000

Type

Hall Button
with Indicator

700

Finished Floor Level


(By others)
JP050

6EA(By others)

80

700

1700

Steel Bar for


Fixing Jamb

Entrance Height(EH) : 2100

1000

700
700

Concrete Opening
OP+140

150

Steel Bar for


Fixing Jambs
9 6EA (By others)

1050

9 6 (By others)
EA

700

500

Steel Bar for


Fixing Jamb

Clear
Clear
Clear
Clear
Clear
Clear
Opening
(OP)
Opening
(OP)
Opening
Opening(OP)
(OP)
Opening
(OP)

30

Concrete Opening(Jamb Height + 50mm)

150

700
Concrete Opening : 2200

Entrance Height (EH) : 2100

HB With HPI

30

Wiring Inlet : 50
(By others)

60

530

90

630

105

630

(Optional)

25

TYPICAL ENTRANCE LAYOUTS


2-Panel Center-Opening Doors (CO)

2 Pannel Side-Opening Doors (2S)

Section Entrance

Plan of Entrance

Section of Entrance

HB With HPI

Clear Opening (OP)

JP100,

JP200

Type

Jamb
Width
Jamb
Jamb
Width
Jamb
JambWidth
Width
Width
Jamb
Width

50

50

Clear Opening (OP)

150

Hall
Button

150

100
JP050

Wall Finish
Thickness

Wall
Thickness

Jamb Width

(180)
Clear Opening (OP)

70

Clear Opening (OP)

130

Type

30
150

70
145

90

JP050

Hall Button

70
Entrance Height (EH) : 2100

70

Entrance Height (EH) : 2100

30
(150)

Jamb Width

Wall Finish
Thickness

30

100

Wall
Thickness

Jamb Width
50

90

130

Plan of Entrance

Type

JP100,

90

JP200

150

Type

130

Note : The above layout is for left side opening. Right side opening doors are available, if requested.

JP050

50

Type

50

50

Type

50

50

50

JP050

Ceiling Line
100
90

Building Structure
(By Other Contractors)

Type

JP200

(with

26

Type

upper

frame)

Entrance Height (EH) : 2100

Jamb Height(JH)
130

50
Building Structure
(By Other Contractors)

130

Wall and Floor Finishing


(By Other Contractors)

Wall and Floor Finishing


(By Other Contractors)

JP100

Jamb Width

50

130

90

Ceiling Height(CH)

Jamb Width

50

50

90

Jamb Width

Entrance Height (EH) : 2100

Jamb Width

10

50

Jamb Width

Ceiling
Line

10

Jamb Height(JH)

Entrance Height (EH) : 2100

Jamb Height (JH)

Ceiling Height

Entrance Height (EH) : 2100

Jamb Height (JH)


Jamb Width

Upper
Frame

10

50

Entrance Height (EH) : 2100

10

Entrance Height (EH) : 2100

100

Upper
Frame

JP200

(without

Type

upper

frame)

JP100

Type

JP200

(with

Type

upper

frame)

JP200

(without

Type

upper

frame)

27

TYPICAL ENTRANCE LAYOUTS

WORKS TO BE DONE BY OTHER CONTRACTORS

2-Panel Up-Sliding Doors (2U) / 4-Panel Center-Opening Doors (2CO)

2-Panel

Up-Sliding

Doors

The following works are not included in the elevator contract, and shall be done by other
contractors in accordance with the Hyundai Elevator s drawings and the applicable codes and
regulations. The reference rules shown are from ANSI A17.1 Code.

(2U)

Entrance Design

Structural Opening of Entrance


500

EH+100

500

Concrete Opening

500

500

Steel Bar for


Fixing Jambs
9 6EA
(By others)
1100

Electrical Work

Hoistway

Hoistway

1. Clear, plumb hoistway with fire resistant hatch walls as required by the governing

1. Light outlet for each elevator, in center of hoistway (or in machine room) as

code. (Rule 100.1a)


2. 75 bevel guards on all projections, recesses or setbacks over 50mm except on side
used for loading or unloading. (Rule 100.6)
3. Venting of the hoistway as required by the governing code or authority. (Rule 100.4)

500

UP

Building Work

250

50
Entrance Height(EH)

Indicator lamp

150

Freight Elev. : 2100~3000


Automobile Elev. : 1800

Hall Button
with Indicator

4. Supports for rail brackets at each floor, roof, and machine room. (Rule 200.9)

indicated by Hyundai Elevator Company.


2. Convenience outlet and light fixture in pit with switch located adjacent to the
access door. (Rule 106.1e)
3. Wiring and piping work of emergency bell, interphone, etc.
Outside the hoistway and the machine room.

Maximum allowable vertical spacing of rail supports, without backing. (Rule 200.4
Finished
Floor Level
(By others)

Clear Opening(OP)

and 301.1) Divider beams 100mm between hoistway at each floor and roof, for
guide rail bracket supports. (Rule 200.4, 200.9 and 301.1)

Concrete Opening(OP)

5. Recesses, supports and patching as required to accommodate hall button boxes,

OP+200

signal fixtures, etc.


6. All barricades either outside elevator hoistways or between elevators inside
hoistways as required.
7. Dry pit reinforced to sustain normal vertical forces from rails and buffers. (Rule
106.1b and 109)

Plan of Entrance

Section of Entrance

Consult Hyundai Elevator Company for rail forces and buffer impacts.
Where there is space below the pit floor which can be occupied, consult Hyundai
Elevator Company for special requirements. (Rule 300.4)

200

Cylinder hole, casings under the pit as required and backfilling around the cylinder
casings when direct plunger type is to be installed.
100

9. Entrance walls and finished floor are not to be constructed until after door frames

200
100

Clear Opening(OP)

and sills are in place.

100

Door frames are to be anchored to walls and properly grouted in place to maintain
legal fire rating.

Notes : 1. The standard location of Hall Button with Indicator for automobile elevators is on left
wall but it is on the right wall for freight elevators.
2. Consult Hyundai if the demensions are less than the minimum.

10. Sill supports 64mm minimum floor recesses full hoistway width for entrance sills,

Entrance Height(EH)

Minimum floor height : Opening Height 3 / 2 + 700mm


Minimum entrance height : 1800mm

4. Lighting, convenience outlets, ventilation, heating of machine room, and machinery


space. (Rule 101.5)
5. Temperature should be maintained below 40C with ventilating fan and/or air
conditioner, if necessary, and humidity below 90%.
6. A fused disconnect switch or circuit breaker for each elevator and light switch
located per the governing code and where practicable located adjacent to the door
of the machine room. (Rule 210.5 and 306.7)
7. Feeder and branch wiring to the controller, including main-line switch and
convenience outlets.
8. Suitable power feeder and branch wiring circuits as required for elevators with
power operated doors, including disconnect switch or circuit breaker.

8. Where access to the pit is by means of the lowest hoistway entrance, vertical iron
ladder extending 1060mm minimum above sill of access door. (Rule 106.1d)

Hall Button
with Indicator

Machine Room

with grouting after sills are set in place.


11. For application as indoor observation elevator, a minimum 3.6m high glass
enclosure above bottom landing is recommended for safety.

Emergency Provisions
9. Elevator fireman s and other emergency services wiring and interconnections to
automatic sprinkler systems or heat and smoke sensing devices furnished by others
and installed to terminal points on the elevator controllers.
10. When emergency power operation of elevators is required, the electrical contractor
should coordinate with Hyundai Elevator Company or local distributor for operation
requirements.
11. Elevator fireman s and other emergency service requirements may differ from each

For application as outdoor observation elevator, full height glass enclosure is

country.

required.

Consult Hyundai Elevator Company or local distributor for other local requirements.
12. When provisions for earthquake protection are required, consult Hyundai Elevator

C e n t e r-Opening

Doors

(2CO)

35

4-Panel

Machine Room

Company for special requirements.

12. Enclosed and protected machine room. (Rule 101.1)

Plan of Entrance

13. Access to the machine room and machinery space as required by the governing

Heat Emission of Machine Room

code or authority. (Rule 101.3)


14. Reinforced concrete machine room floor slab or grating, as specified, which must
200

not be placed over the hoistway until elevator machinery is set in position. (Rule
100.3 for Traction Elevator)
15. Hoisting beams, trap doors and other means of access to machine room for

Q (Kcal/H) = W V F N
W: Capacity (kg)

N : Number of cars

V : Speed (m/min)
F : Factor (1/40: VVVF)

maintenance and equipment removal purposes. (Rule 101.3d)


16. Cable guards in the machine room or secondary level. (Rule 104.1)
17. Supports for machine and sheave beams and reactions including wall pockets and
patching after beams are set in place. (Rule 105.1 to 105.5)

28

29

ELECTRIC POWER REQUIREMENTS (By others)


(50/60Hz, 380V)

Persons / Kg

6 / 450

8 / 550

9 / 600

10 / 700

11 / 750

13 / 900

15 / 1000

17 / 1150

20 / 1350

24 / 1600

MCCB(A)

Cable (mm )

Earth (mm )
2

Speed
(m/min)

Motor
(kW)

1Car

2Cars

1Car

2Cars

1Car

2Cars

1Car

2Cars

60

5.5 (2.8)

20 (20)

30 (20)

4 (3)

7 (5)

4 (4)

6 (4)

4 (6)

4 (6)

90

7.5 (4.2)

20 (20)

30 (40)

6 (4)

10 (8)

4 (4)

6 (10)

4 (6)

6 (6)

105

7.5 (4.9)

20 (20)

40 (40)

7 (5)

12 (9)

4 (4)

10 (10)

4 (6)

6 (6)

60

5.5 (3.4)

20 (20)

30 (20)

5 (4)

9 (6)

4 (4)

6 (4)

4 (6)

4 (6)

90

7.5 (5.1)

20 (20)

30 (40)

7 (5)

13 (10)

4 (4)

6 (10)

4 (6)

4 (6)

105

11 (5.9)

30 (20)

50 (40)

8 (6)

15 (11)

6 (4)

16 (10)

4 (6)

6 (6)

60

5.5 (3.7)

20 (20)

30 (30)

5 (4)

9(7)

4 (4)

6 (6)

4 (6)

4 (6)

90

11 (5.6)

30 (20)

50 (40)

8 (6)

14 (11)

6 (4)

16 (10)

4 (6)

6 (10)

105

11 (6.5)

30 (20)

50 (40)

9 (7)

16 (12)

6 (4)

16 (10)

4 (6)

6 (10)

60

7.5 (4.3)

20 (20)

40 (30)

6 (5)

11 (8)

4 (4)

10 (6)

4 (6)

6 (6)

90

11 (6.5)

30 (20)

50 (40)

9 (7)

16 (12)

6 (4)

16 (10)

4 (6)

6 (6)

105

11 (7.6)

30 (20)

60 (40)

11 (9)

19 (14)

6 (4)

16 (10)

4 (6)

10 (6)

60

7.5 (4.6)

20 (20)

40 (30)

6 (5)

12 (9)

4 (4)

10 (6)

4 (6)

6 (6)

90

11 (6.9)

30 (20)

50 (40)

10 (7)

17 (13)

6 (4)

16 (10)

4 (6)

6 (10)

105

11 (8.1)

30 (30)

60 (50)

11 (9)

20 (15)

10 (6)

16 (16)

4 (6)

10 (10)

120

(9.2)

(30)

(50)

(10)

(18)

(6)

(16)

(6)

(10)

60

11 (5.6)

30 (20)

50 (30)

8 (6)

14 (11)

6 (4)

10 (6)

4 (6)

6 (6)

90

15 (8.3)

40 (30)

60 (50)

12 (9)

21 (16)

10 (6)

16 (16)

6 (6)

10 (10)

105

15 (9.7)

40 (30)

75 (50)

14 (10)

24 (18)

10 (6)

25 (16)

6 (6)

10 (10)

120

(11.1)

(30)

(60)

(12)

(21)

(6)

(16)

(6)

(10)

150

(13.8)

(50)

(100)

(15)

(28)

(10)

(25)

(6)

(16)

60

11 (6.2)

30 (20)

50 (40)

9 (7)

15 (12)

6 (4)

16 (10)

4 (6)

6 (10)

90

15 (9.2)

40 (30)

75 (50)

13 (10)

23 (18)

10 (6)

25 (16)

6 (6)

10 (10)

105

15 (10.8)

40 (30)

75 (60)

15 (11)

27 (20)

10 (6)

25 (16)

6 (6)

10 (10)

120

(12.3)

(40)

(75)

(13)

(23)

(10)

(25)

(6)

(16)

150

(15.4)

(50)

(100)

(17)

(31)

(10)

(25)

(6)

(16)

60

11 (7.1)

30 (20)

50 (40)

10 (8)

18 (13)

6 (4)

16 (10)

4 (6)

6 (10)

90

15 (10.6)

40 (30)

75 (60)

15 (11)

27 (20)

10 (6)

25 (16)

6 (6)

10 (10)

105

18.5 (12.4)

50 (30)

100 (60)

17 (13)

31 (23)

16 (6)

35 (16)

6 (6)

10 (16)

120

(14.1)

(40)

(75)

(15)

(27)

(10)

(25)

(6)

(16)

150

(17.7)

(60)

(100)

(20)

(35)

(10)

(25)

(6)

(16)

60

15 (8.3)

30 (20)

60 (40)

12 (9)

21 (16)

10 (4)

16 (10)

6 (6)

6 (6)

90

18.5 (12.5)

50 (40)

100 (75)

17 (13)

31 (24)

16 (10)

25 (25)

6 (6)

10 (10)

105

22 (14.5)

50 (40)

100 (75)

20 (15)

37 (28)

16 (10)

35 (25)

6 (6)

10 (10)

120

(16.6)

(40)

(100)

(17)

(31)

(10)

(25)

(6)

(10)

150

(20.7)

(75)

(125)

(23)

(41)

(16)

(35)

(10)

(25)

60

15 (9.9)

40 (30)

75 (50)

14 (10)

25 (19)

10 (6)

25 (16)

6 (6)

10 (6)

90

22 (14.8)

50 (50)

100 (75)

21 (16)

37 (28)

16 (10)

35 (25)

6 (6)

10 (10)

105

22 (17.2)

60 (50)

125 (100)

24 (18)

43 (33)

16 (16)

35 (25)

10 (6)

16 (10)

120

(19.7)

(50)

(100)

(21)

(37)

(16)

(25)

(6)

(10)

150

(24.5)

(75)

(150)

(27)

(49)

(16)

(50)

(10)

(35)

Notes : 1. Above power feeder sizes are for the length of electric wire up to 50m from
elevator machine room to power.
For the length being 50m or more, the following formular should be applied.
2. Above cable sizes are for copper wires inside electrometallic tubings.
Size in the above(mm2)
Cable sizes(mm 2) = Cable length(m)
50

30

Power(KVA)

AC-Gearless 180~600m/min

3. For power requirement of 3 cars or more, consult Hyundai.


4. Machine room temperature should be maintained below 40 C with ventilating fan
and air conditioner, and humidity below 90%.
5. Data shown in ( ) is applied to the Machine-Room-Less elevators and gearless elevators.

Persons / kg

Speed (m/min)

13 / 900
15 / 1000

17 / 1150
20 / 1350

24 / 1600

(50/60Hz, 380v)

Transformer Capacity
(kVA)

C.B. Rated Current


(A)

Motor (kW)

Earth Wire
(mm2)

Power Feeder
(mm2)

1Car

2Cars

1Car

2Cars

1Car

2Cars

1Car

2Cars

180

16.6

50

100

18

33

10

25

16

180
210
240
180
210
240
180
210
240
180
210
240

18.4
23
26
21.2
25
30
25
30
35
30
35
40

60
75
100
75
75
100
75
100
125
100
125
125

100
125
150
125
150
175
150
175
200
175
200
225

20
26
29
24
28
33
28
33
39
33
39
44

37
46
52
42
50
60
50
60
70
60
70
80

10
16
25
16
16
25
16
25
35
25
35
35

25
35
50
35
50
50
50
50
70
50
70
70

6
10
16
10
10
16
10
16
25
16
25
25

16
25
35
25
35
35
35
35
50
35
50
50

Notes : 1. The above power sizes are for lengths of electric wire up to 50m from the elevator machine
room to the transformer.
For lengths of 50m or more, the following formula should be applied :
Power feeder length (m)
50

Power feeder size (mm2) =


Number of elevator(N)
Diversity factor

size in the above (mm2)

1.00

0.91

0.85

0.80

0.76

2. Above power feeder sizes are for copper wires inside electro-metallic tubing.
3. It is recommended a larger diameter earth wire be used.
4. For installing several elevators, apply the following formula.
Transformer Capacity (kVA) = Number of elevator X Diversity factor
5. Consult Hyundai if you need electric power requirements for 220V.
6. For AC-Geared elevators, consult Hyundai.
7. For AC-Gearless elevators(300m/min ~ 1080m/min), consult Hyundai.

Hydraulic
Persons /
kg
6 / 450
8 / 550
9 / 600
10 / 680
11 / 750
13 / 900
15 / 1000
17 / 1150
20 / 1350
24 / 1600

(50/60Hz, 380v)

Speed
(m/min)

Motor (kW)

30
45
30
45
30
45
30
45
30
45
30
45
30
45
30
45
30
45
30
45

15
22
18.5
30
18.5
30
18.5
30
18.5
30
30
37
30
37
37
52
37
52
37
52

C.B. Rated
Current (A)

Transformer Power Feeder


Capacity (kVA)
(mm2)

1Car

2Car

1Car

2Car

1Car

2Car

1Car

2Car

50
75
75
100
75
100
75
100
75
100
100
125
100
125
125
175
125
175
125
175

100
150
125
175
125
175
125
175
125
175
175
225
175
225
225
300
225
300
225
300

25
38
30
49
30
49
30
49
30
49
49
62
49
62
62
81
62
81
62
81

45
70
56
90
56
90
56
90
56
90
90
113
90
113
113
148
113
148
113
148

10
16
16
25
16
25
16
25
16
25
25
35
25
35
35
50
35
50
35
50

25
50
35
70
35
70
35
70
35
70
70
120
70
120
120
150
120
150
120
150

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
6
10
6
10

6
10
6
10
6
10
6
10
6
10
10
10
10
16
16
25
16
25
16
25

Earth Wire
(mm2)

Notes : 1. Above power feeder sizes are for the length of electric wire up to 50m from elevator machine room to transformer.
For the length being 50m or more, the following formular should be applied:
Power feeder length(m)
2. Above power feeder sizes are for copper wires inside electrometallic tubings. Power feeder sizes(mm2) =
50
3. For power requirement of 3 cars or more, consult Hyundai.
4. Machine room temperature should be maintained below 40C with ventilating fan and air conditioner, and humidity below 90%.
5. The heat emission and ventilation of machine room on above dimensions may vary slightly with the machine room size and
peripheral environment.
6. Consult Hyundai if you need electric power requirements for 220V.

Heat Emission of
Ventilation of
Machine Room (kcal/h) Machine Room (m2/h)
1Car
2Car
1Car
2Car
3000
3900
3500
5500
3500
5500
3500
5500
3500
5500
5500
6900
5500
6900
6900
9700
6900
9700
6900
9700

6000
7800
7000
11000
7000
11000
7000
11000
7000
11000
11000
13800
11000
13800
13800
19400
13800
19400
13800
19400

1000
1300
1100
1900
1100
1900
1100
1900
1100
1900
1900
2300
1900
2300
2300
3500
2300
3500
2300
3500

2000
2600
2200
3800
2200
3800
2200
3800
2200
3800
3800
4600
3800
4600
4600
7000
4600
7000
4600
7000

Size in the above(mm2)

31

MILLENNIUM ESCALATORS (30 )

MILLENNIUM ESCALATORS (35 )

ML-BT, ML-BB

ML-BT, ML-BB

Floor Opening AA
C

1.732H

B ( B+400)
Floor Opening AA
(See note5) Min. 2500

2367 ( 2767)

1.428H

2088
50

1777

Floor Opening Enclosures (By Others)

(See note5) Min.2500


50

Floor Opening Enclosures (By Others)


1000

793
1498

Working
Point

R1
Wiring Inlet

2139

(By Others)

935

H=Rise

(See note5) Min.2500

968

H=Rise

(By Others)

Min.2300

1000

50
Wiring Inlet

950

R1

950

793
908

Working
Point

Head Room

(See note5) Min. 2500

Min. 2300

Head Room

50

935

35

7600 H 10500

Section Dimensions

H 6000

90

1014
1257
1550
1500
1650

Top of Finish Floor


(By Others)
Min.

813
1056
1349
1298
1449

J
Notes : 1. AA = 1.428 H + 2367 (*2767) + 2088 + 100
2. Qty of flat step : 2
3. In case inverter system is applied, consult Hyundai.
4. Escalator for subway or semi-outdoor escalator : ( )Dimension
5. Dimension between the end of handrail to the wall; Min.2500mm
6. Maximum rise : 6000mm is available.
7. In case EN115 is applied, consult Hyundai.

2286 2080 1695 1490 2116 2250 4230


2876 2606 2237 1967 2707 2777 4750
30~40
m/min

3476 2606 2236 1966 3306 2777 4770


3882 3012 2642 2372 3712 3183 5170

Vertical Rise
H(mm) Reactions

130

594
837
1130
1080
1230

Reactions

Min. 200

11(Shim)

W1
W2
W3
W4
W5

ML1000 ML1200

6000 H 7600 30m/min 2693 2487 2102 1897 2523 2657 4640

Typical Concrete Support

(Unit : mm)

3000
~6000

R1
R2

ML800

ML1000

ML1200

0.66H+2600 0.73H+2900 0.79H+3200


0.66H+2000 0.73H+2300 0.79H+2600

L200 200 20

Type
W1
W2
W3
W4
W5

ML800
612
855
1148
1098
1248

ML1000 ML1200
813
1056
1349
1299
1449

1014
1257
1550
1500
1650

Min. 200

Reinforced Plate
(By Others)

32

ML1000

ML1200

Note : When vertical rise is over 6000mm or AA is over 14835mm,


consult Hyundai for reactions data.

Base Plate 150 19

L200 200 20

Notes : 1. When maximum floor opening exceeds AA=14835mm,


intermediate support(s) are required.
Consult Hyundai for the intermediate support data.
2. Consult Hyundai if the isolation pad is applied.

Min. 200

(Speed : 30m/min)

Type

Vertical Rise H(mm)

W800
W1000
W1200
Motor (kW)

H 7600 H 10500
H 5570 H 7600 H 10500
H 4460 H 6100 H 8900 H 10500
5.5
7.5
11
15

Note : When speed is over 40m/min, consult Hyundai.

90

130

Min.

935

Motor Application

11(Shim)

Top of Finish Floor


(By Others)
Floor Opening
Enclosure
(By Others)

90

130

Min.

935

11(Shim)

Top of Finish Floor


(By Others)

50 50

W5

ML800

0.52H+2700 0.6H+3000 0.67H+3300


0.52H+2200 0.6H+2500 0.67H+2700

Typical Steel Support

w3
w2
w1

Min. 200

L200 200 20

w4

3000
~6000

R1
R2

(Unit : kg)

50 50

Typical Steel Support

Floor Opening
Enclosure
(By Others)

Vertical Rise
H(mm) Reactions

Top of Finish Floor


(By Others)

50 50

w3
w2
w1

Reactions

Typical Concrete Support

(Unit : mm)

Note : When vertical rise is over 6000mm or AA is over 14835mm,


consult Hyundai for reactions data.

Base Plate 150 19

Section Dimensions

(Unit : kg)

Min.

H 6000

130

ML-BT
ML-BB

Min. 4100

11(Shim)

Model
Q ty of Vertical Rise H Speed
(mm)
(Inclination) Flat Step

ML800

Working
Point

2316

Notes : 1. AA = 1.732H + B + C + 100


2. In case inverter system is applied, consult Hyundai.
3. Escalator for subway or semi-outdoor escalator :
( )Dimension
4. When vertical rise is over 6000mm, 3-flat step is applied.
5. Dimension between the end of handrail to the wall ; Min.2500mm
6. In case EN115 is applied, consult Hyundai.

Type

1000

R2

Min.

1100

Working
Point

90

1000

R2

Min. 1100

30

L200 200 20

Motor Application

(Speed : 30m/min)

50 50
Reinforced Plate
(By Others)

w4
w5

Notes : 1. When maximum floor opening exceeds AA=14835mm,


intermediate support(s) are required, Consult Hyundai
for the intermediate support data.
2. Consult Hyundai if the isolation pad is applied.

Type
W800
W1000
W1200
Motor (kW)

Vertical Rise H(mm)


H 6000
H 5570
H 4460
5.5

H 6000
H 6000
7.5

33

H-SERIES ESCALATORS

MODULAR ESCALATORS

HA-BT, HA-BB

M-BT, M-BB

Floor Opening AA
4100 (Min. 3750)

50
Floor Opening AA

(See notes3) Min.2500

2640

R1

Soffit Guard
(By Others)

(By Others)

[AA]/(N+1)

[AA]/(N+1)

H=Rise

30

2967

Top of Finish Floor


(By Others)
90

Min.

(Unit : mm)

Type HA800 HA1000 HA1200


Base Plate 150 19

1014
1406
1750
1700
1850

L200 200 24

50 50

Section Dimensions

90

155

L200 200 24

594
895
1275
1244
1375

1014
1342
1695
1664
1795

Reactions

w5
w3
w2
w1

8800
22404
6360
5660
10850
7030
6190
11840
7570
6700
12860
-

9200
23097
6530
5830
11170
7210
6360
12190
7770
6900
13240
-

9600
23790
6700
6000
11480
7400
6540
12540
7970
7090
13620
-

10000
24483
4980
4210
8040
7760
5540
4600
8770
8480
5990
4990
9520
9210

10400
25175
5100
4320
8250
7980
5670
4720
9000
8710
6130
5120
9770
9470

10800
25868
5220
4430
8450
8190
5800
4840
9230
8950
6270
5250
10010
9720

11200
26561
5330
4540
8660
8410
5920
4960
9460
9190
6410
5380
10260
9980

11600
27254
5450
4650
8870
8630
6050
5080
9690
9420
6550
5510
10520
10240

12000
27847
5570
4760
9090
8840
6180
5200
9920
9660
6680
5640
10770
10500

12400
28539
5680
4870
9300
9060
6310
5320
10150
9900
6820
5770
11020
10760

12800
29332
5800
4980
9510
9280
6430
5440
10380
10130
6960
5900
11270
11010

13200
29925
5910
5090
9720
9490
6560
5560
10610
10370
7090
6030
11520
11270

13600
30718
6030
5200
9930
9710
6680
5680
10840
10610
7230
6160
11770
11530

933

(Unit : kg)

8400
21711
6190
5500
10530
6840
6000
11500
7370
6510
12480
-

L200 200 20

Typical Steel Support

3800
R1=485(AA+0.1) - 3800 +1500 R1=635(AA+0.1) - AA+0.1 + 1800
AA+0.1
R2=485(AA+0.1) + 3800 +600
AA+0.1

R2=635(AA+0.1) + 3800 + 800


AA+0.1

Motor Application

Floor Opening
Enclosure
(By Others)

Type

Top of Finish Floor


(By Others)

L200 200 20
50 50

w4
w 4+200

Speed : 30m/min

Min. 200

90

w 4 + 200

Base Plate 150 19

M1200

50 50

Notes : 1. When maximum floor opening exceeds


AA=10000mm, intermediate support(s) are required.
Consult Hyundai for the intermediate support data.
2. Consult Hyundai if the isolation pad is applied.

w4

90

W1
W2
W3
W4
W5

(Unit : kg)

M800

Top of Finish Floor


(By Others)
Min.

M1200

50 50

Reinforced Plate
(By Others)

Note : Above dimensions are applied in case the 3 flat step


is standard.

M800

130

Min.

Floor Opening
Enclosure
(By Others)

936

Vertical Rise : H(mm)

Top of Finish Floor


(By Others)
11(Shim)

Motor Application (Speed : 30m/min)

Type

Min. 200

130

Min. 200

w5
w3
w2
w1

Reactions

Typical Concrete Support

(Unit : mm)

11(Shim)

813
1205
1549
1499
1650

Min.

594
986
1330
1280
1430

11(Shim)

W1
W2
W3
W4
W5

Typical Steel Support

HA800 H 13000 H 15000


HA1000
H 13400 H 15000
HA1200
H 11000 H 12800 H 15000
Motor (kW)
11
16
18.5
22

Notes : 1. AA=1.732 x H + 3398 + 2709 + 100


2. Dimension between the end of handrail to the wall: Min. 2500mm
3. In case inverter system is applied, consult Hyundai.
4. In case EN115 is applied, consult Hyundai.

Min. 5000
155

Section Dimensions

11(Shim)

Notes : 1. N : Number of intermediate support


Max. distance between intermediate support
10000mm
AA=1.732 x H + 4100 (3750) + 2963 (2750) + 100
2. Dimension between the end of handrail to the
wall: Min. 2500mm
3. In case inverter system is applied, consult
Hyundai.
4. In case EN115 is applied, consult Hyundai.

Working
Point

1073

Min.

R2

1125

Typical Concrete Support


Min. 200

8000
21019
6010
5330
10210
6650
5820
11150
7160
6310
12110
-

Intermediate
Support
(By Others)

400R

933

Min.1400

1200

(By Others)

Working
Point

[AA]/(N+1)

7600
20326
5840
5170
9890
6470
5640
10800
6960
6120
11730
-

0
106

30

1980

Min. 5700

Vertical Rise H (mm)


Floor Opening AA(mm)
R1
R2
HA800
R3
R4
R1
R2
HA1000
R3
R4
R1
R2
HA1200
R3
R4

R1

3127
Wiring Inlet

3085 (Min. 2872)

Type

Working
Point
699

Min.2300

Wiring Inlet

(See notes2) Min.2500


R2

(See notes2) Min.2500

Floor Opening Enclosures (By Others)

803

Intermediate
Support
(By Others)

R4

50

2670

3978
(Min. 3628)

R3
H=Rise

Min. 290

793

0
110

908
377
R

936

1200

Working
Point

Min. 2300

2150

3398

936

Soffit Guard
(By Others)

(See notes3) Min.2500

1.732H

2709

50
Floor Opening Enclosures (By Others)

1073

1.732H

2963
(Min. 2750)

50

Reinforced Plate
(By Others)

Notes : 1. When maximum floor opening exceeds


AA=10000mm, intermediate support(s) are required.
Consult Hyundai for the intermediate support data.
2. Consult Hyundai if the isolation pad is applied.

M800

2440
H
H
Vertical
H
Rise :
H
H(mm)
H

H 3660
9140
10970
14980
27430
36580

M1200
2440
H
H
H
H
H
H
H

MOTOR (kw)

H 3660
6100
7320
11000
18290
24380
30480
36580

5.5
7.5
5.5
7.5
7.5
7.5
7.5
7.5

1
1
2
2
3
4
5
6

Note : When vertical rise is over 36580mm, consult Hyundai.

Note : When maximum vertical rise ranges over 15000mm, consult Hyundai.

34

35

MOVING WALKS

ELECTRIC POWER REQUIREMENTS (By others)

PM-BT

There are some building and electrical work which is necessary for a normal escalator installation,
but is not done by the escalator contractor. Please consult Hyundai for it.

Horizontal Type
w3
w2
w1

Length Overall = L
868

868

Length Between Combplates

Electric Power

50
Comb
Comb
Comb
Comb
Comb
Line
Line
Line
Line
Line
Line

Type

1030

1030

1100

Floor Opening
Enclosure
(By Others)

560

937

Comb
Comb
Comb
Comb
Comb
Comb
Line
Line
Line
Line
Line

50

Motor
(kW)

Power Supply
Power Supply
Capacity(kVA) Voltage (AC-3Phase)

5.5

12

7.5

14

5.5 2/11

19

7.5 2

27

7.5 3

40

7.5 4

52

7.5 5

65

7.5 6

78

11

19

16

25

18.5

31

22

36

26

40

Wiring Inlet
Min. 4000

Min. 3220
Min. 5435

(By Others)

5435

w4
w5
Millennium
&

Horizontal & Inclined Type

Modular

Floor Opening AA
2660

4.7046 H
Floor Opening
Enclosures
(By Others)

50

H=Rise

937
753

Working
Point

1030

W1
W2
W3
W4
W5

594
838
1130
1080
1230

813
1054
1346
1296
1445

1014
1257
1549
1499
1650

1251
1494
1786
1736
1888

1434
1677
1969
1919
2070

3743

12

Wiring Inlet

Working
Point

Typical Concrete Support

(By Others)

1892

Min. 200

135

11(Shim)

Min.

Top of Finish Floor


(By Others)

Min. 8110

90

1100

(Unit : mm)

Type PM800 PM1000 PM1200 PM1400 PM1600

1917

Min.2200

2232
50

Section Dimensions

1030

2975

Base Plate 150 19

L200 200 25

H-Series

50 50

Compact Type
Floor Opening AA
2660

4.7046 H

Typical Steel Support


1917

1100

12

1030

L200 200 25

3743
(By Others)

Working
Point

Min. 5670

10
6
6
10
6
6
16
6
6
25
6
6
35
10
6
35
16
10
50
16
16
50
25
16

16
6
6
25
6
6
25
10
6
35
16
10
50
25
16
95
25
25
95
35
25
120
35
25

100
50
40
125
60
50
150
75
75
175
100
75

16
6
6
25
6
6
25
10
6
25
10
6
35
16
6

175
125
100

35
16
10
35
16
10
35
25
16
95
25
25
120
35
25
120
50
35
185
70
35
185
95
50

50
16
16
50
25
16
95
35
25
120
50
35
185
70
35
185
95
50
240
95
70

35
16
16
50
25
16
70
25
25
120
35
25
150
50
35
185
95
50
240
95
70
300
120
95

25
10
6
35
16
10
35
16
16

25
10
6
35
10
6
35
16
10
50
25
16
50
35
25
120
35
25
120
50
35
150
50
35
35
16
10
50
25
16
50
25
16

35
16
10

50
25
16
70
25
16
95
35
25

50
25
16
95
35
25
120
35
25

95
25
25
120
35
25
120
35
35

50
16
16

95
25
25

120
35
25

120
35
35

150
50
35

50
25
16

95
35
25

120
35
25

120
50
35

150
50
35

Lighting Power

135

11(Shim)

Top of Finish Floor


(By Others)

50 50

Wiring Inlet

1100

36

H=Rise

753

12
12
12

937

Min. 2200

492
50

50
30
30
60
40
30
75
50
40
125
75
60
175
100
100
225
150
125
300
175
150
350
200
175

Min. 200
50

90

Floor Opening
Enclosures
(By Others)

Min.

1000

Power Feeder(mm2) (from power room to escalator controller)


20m
40m
60m
80m
100m
120m

C.B. Rated
Current (A)

Reinforced Plate
(By Others)

Notes : 1. When the intermediate supports are required, please


consult Hyundai for the intermediate support data.
2. Consult Hyundai if the isolation pad is applied.
3. In case EN115 is applied, consult Hyundai.

Balustrade Vertical Power Supply Power Supply C.B. Rated


Voltage
Type
Rise (m) Capacity (kVA) (AC-1phase) Current (A)
1.83-4.27
With Handrail 4.28-7.6
Lighting
(BTL Type) 1.83-4.27
4.28-7.6
Without Handrail
Lighting

1.4(3)
2(6)
1.4(3)
2(6)
1.2

100-110
200-265
100-110
200-265

30(40)
40(70)
20
20(40)
20

20m
6
6

Power Feeder(mm2)
40m 60m 80m 100m 120m
10

16

10
4
4

2.5
2.5

16

25
10
10

6
6
4

6
4

10
10

3 , 200V, 50Hz 3 , 220V, 60Hz


3 , 346V, 50Hz 3 , 380V, 60Hz
3 , 415V, 50Hz 3 , 460V, 60Hz

Notes : 1. Consult Hyundai when the rise over 7600mm.


2. The capacity shown by ( ) mark shall be applied to moving walks.

37