You are on page 1of 21

IF Cable connector

H Type
yp connector-ODU
H-LP-8DFB(S)

L Type connector-IDU
N-LP-8DFB
N-LP-TNC

IF Cable connector

H Type connector-ODU
H-LP-8DFB(S)

L Type connector-IDU
N-LP-8DFB
N LP TNC
N-LP-TNC

H Type connetor constitution

January 13, 2007

NEC Corporation 2007

ODU H Type connector installation

January 13, 2007

NEC Corporation 2007

IF Cable connector

H Type connector-ODU
H-LP-8DFB(S)

L Type connector-IDU
N-LP-8DFB
N LP TNC
N-LP-TNC

N-LP-8DFB

January 13, 2007

IDU Instruction

NEC Corporation 2007

L-Type connector-1

1 Take off the Tightenig nut fitting and take each part from the mainbody
1.
mainbody.
January 13, 2007

NEC Corporation 2007

L-Type connector-2

2. Two ggasket attached. Use only


y 1 gasket
g
and store the other one.
January 13, 2007

NEC Corporation 2007

L-Type
yp connector-3
Clamp

Hood

3.Insert the clamp to the stripped cable jacket end. Open the end of the outer conductor a
little.
4. Insert the hood between the plastic tape with aluminum foil and the outer conductor.
5. No gap is allowed in between the clamp, the outer conductor and the hood.
January 13, 2007

NEC Corporation 2007

L-Type connector-4

6. After inserting the hood, cut off the plastic tape with aluminum foil and the
dielectric at A
A-surface
surface.
7. Cut off the part of the outer conductor exceeding the clamp rim with a scissor.
8. Check that distance between the tip of the center conductor and A-Surface is
6 7mm Chamfer at the tip of the inner conductor.
6-7mm.
conductor
January 13, 2007

NEC Corporation 2007

10

L-Type connector-5

9. Insert the insulation washer to the center conductor, and engage it the F/f
Contact.
10 N
10.
No gap iis allowed
ll
d iin bbetween
t
th
the F/F C
Contact,
t t th
the iinsulation
l ti washer,
h
and the dielectric.
11. Combine the convex part of the clamp to the concave part of the gasket.
January 13, 2007

NEC Corporation 2007

11

L-Type connector-6

1-2mm

12. Tighten the tightening nut sufficiently until the gasket is cut by the
13. Torque fot the tightening nut shall be 8-30N-m.
g
g nut is 1-2mm.
14. Distance between the tightening
January 13, 2007

NEC Corporation 2007

12

IF Cable connector

L Type connector-IDU
N-LP-8DFB

N-LP-TNC

TNC connector making instruction-1

January 13, 2007

NEC Corporation 2007

14

TNC connector making instruction-2

January 13, 2007

NEC Corporation 2007

15

TNC connector making instruction-3

January 13, 2007

NEC Corporation 2007

16

TNC connector making instruction-4

January 13, 2007

NEC Corporation 2007

17

TNC connector making picture-1

January 13, 2007

NEC Corporation 2007

18

TNC connector making picture-2

January 13, 2007

NEC Corporation 2007

19

TNC connector making picture-3

January 13, 2007

NEC Corporation 2007

20

TNC connector making picture-4

January 13, 2007

NEC Corporation 2007

21