You are on page 1of 22

Basic Electrical Lab 2010

Practical Number 01
Identify various resistances and understand their specifications

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 1

Basic Electrical Lab 2010


Objective:
To identify various resistors & measure their value using Color Code identification Methode. .

Equipments and components:


Resistors with 4 ,5 & 6 Bands ,Resistor Banks, Resistor in IC Package, Wire wound Resistor

Theory :
Resistor Types
There are many different Resistor Types and they are produced in a variety of forms because their
particular characteristics and accuracy suit certain areas of application, such as High Stability, High
Voltage, High Current etc, or are used as general purpose resistors where their characteristics are less of a
problem. Some of the common characteristics associated with the humble resistor are; Temperature
Coefficient, Voltage Coefficient, Noise, Frequency Response, Power as well as Temperature Rating,
Physical Size and Reliability.
All modern resistors can be classified into four broad groups;
1. Carbon Composition Resistor - Made of carbon dust or graphite paste, low wattage values
2. Film or Cermet Resistor - Made from conductive metal oxide paste, very low wattage values
3. Wire-Wound Resistors. - Metallic bodies for heatsink mounting, very high wattage ratings
4. Semiconductor Resistors - High frequency/precision surface mount thin film technology
Composition Resistors
Carbon Resistors are the most common type of Composition Resistors as they are a cheap general
purpose resistor. Their resistive element is manufactured from a mixture of finely ground carbon dust or
graphite (similar to pencil lead) and a non-conducting ceramic (clay) powder to bind it all together. The
ratio of carbon to ceramic determines the overall resistive value of the mixture and the higher this ratio is
the lower the resistance. The mixture is then moulded into a cylindrical shape and metal wires or leads are
attached to each end to provide the electrical connection before being coated with an outer insulating
material and colour coded markings.
Carbon Resistor

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 2

Basic Electrical Lab 2010


Carbon Composite Resistors are low to medium power resistors with low inductance which makes them
ideal for high frequency applications but they can also suffer from noise and stability when hot. Carbon
composite resistors are prefixed with a "CR" notation (eg CR10k) and are available in E6 (20%
tolerance (accuracy)), E12 (10% tolerance) and E24 (5% & 2% tolerance) packages with power
ratings from 0.125 or 1/4 Watt up to 2 Watts.
Film Resistors
The generic term "Film Resistor" consist of Metal Film, Carbon Film and Metal Oxide Film resistor
types, which are generally made by depositing pure metals, such as nickel, or an oxide film, such as tinoxide, onto an insulating ceramic rod or substrate. The resistive value of the resistor is controlled by
increasing the desired thickness of the film and then by laser cutting a spiral helix groove type pattern into
this film. This has the effect of increasing the conductive or resistive path, a bit like taking a long length
of straight wire and forming it into a coil.
This method of manufacture allows for much closer tolerance resistors (1% or less) as compared to the
simpler carbon composition types. The tolerance of a resistor is the difference between the preferred value
(i.e, 100 ohms) and its actual manufactured value i.e, 103.6 ohms, and is expressed as a percentage, for
example 5%, 10% etc, and in our example the actual tolerance is 3.6%. Film type resistors also achieve a
much higher maximum ohmic value compared to other types and values in excess of 10M (10
Million s) are available.
Film Resistor

Metal Film Resistors have much better temperature stability than their carbon equivalents, lower noise
and are generally better for high frequency or radio frequency applications. Metal Oxide Resistors have
better high surge current capability with a much higher temperature rating than the equivalent metal film
resistors.
Another type of film resistor commonly known as a Thick Film Resistor is manufactured by depositing a
much thicker conductive paste of CERamic and METal, called Cermet, onto an alumina ceramic
substrate. Cermet resistors have similar properties to metal film resistors and are generally used for
making small surface mount chip type resistors, multi-resistor networks in one package for pcb's and high
frequency resistors. They have good temperature stability, low noise, and good voltage ratings but low
surge current properties.
Metal Film Resistors are prefixed with a "MFR" notation (eg MFR100k) and a CF for Carbon Film
types. Metal film resistors are available in E24 (5% & 2% tolerances), E96 (1% tolerance) and E192

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 3

Basic Electrical Lab 2010


(0.5%, 0.25% & 0.1% tolerances) packages with power ratings of 0.05 (1/20th) of a Watt up to 1/2
Watt. Generally speaking Film resistors are precision low power components.
Wirewound Resistors
Another type of resistor, called a Wirewound Resistor, is made by winding a thin metal alloy wire
(Nichrome) or similar wire onto an insulating ceramic former in the form of a spiral helix similar to the
Film Resistors. These types of resistors are generally only available in very low ohmic high precision
values (from 0.01 to 100k) due to the gauge of the wire and number of turns possible on the former
making them ideal for use in measuring circuits and Whetstone bridge type applications.
They are also able to handle much higher electrical currents than other resistors of the same ohmic value
with power ratings in excess of 300 Watts. These high power resistors are moulded or pressed into an
aluminum heat sink body with fins attached to increase their overall surface area to promote heat loss.
These types of resistors are called "Chassis Mounted Resistors". They are designed to be physically
mounted onto heatsinks or metal plates to further dissipate the generated heat increasing their current
carrying capabilities even further.
Another type of wirewound resistor is the Power Wirewound Resistor. These are high temperature, high
power non-inductive resistor types generally coated with a vitreos or glass epoxy enamel for use in
resistance banks or DC motor/servo control and dynamic braking applications. The non-inductive
resistance wire is wound around a ceramic or porcelain tube covered with mica to prevent the alloy wires
from moving when hot.
Because the wire is wound into a coil, it acts like an inductor causing them to have inductance as well as
resistance and this affects the way the resistor behaves in AC circuits by producing a phase shift at high
frequencies especially in the larger size resistors. The wire wound resistors must not be designed into AC
or amplifier type circuits where the frequency across the resistor changes. However, special non-inductive
wirewound resistors are also available.
Wirewound Resistor

Wirewound resistor types are prefixed with a "WH" or "W" notation (eg WH10) and are available in the
WH Aluminium Cladded package (1%, 2%, 5% & 10% tolerance) or the W Vitreous Enamelled
package (1%, 2% & 5% tolerance) with power ratings from 1W to 300W or more.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 4

Basic Electrical Lab 2010


Resistor Color Code Identification

The standard color coding method for resistors uses a different color to represent each number 0 to 9:
black, brown, red, orange, yellow, green, blue, purple, grey, white. On a 4 band resistor, the first two
bands represent the significant digits. On a 5 and 6 band, the first three bands are the significant digits.
The next band represents the multiplier or "decade". As in the above 4 band example, the first two bands
are red and purple, representing 2 and 7. The third band is orange, representing 3 meaning 103 or 1000.
This gives a value of 27 * 1000, or 27000 Ohms. The gold and silver decade bands divide by a power of
10, allowing for values below 10 Ohms. The 5 and 6 band resistors work exactly the same as the 4 band
resistor. They just add one more significant digit. The band after the decade is the tolerance. This tells
how accurate the resistance compared to its specification. The 4 band resistor has a gold tolerance, or 5%,
meaning that the true value of the resistor could be 5% more or less than 27000 Ohms, allowing values
between 25650 to 28350 Ohms. The last band on a 6 band resistor is the temperature coefficient of the
resistor, measured in PPM/C or parts per million per degree Centigrade. Brown (100 PPM/C) are the most
popular, and will work for most reasonable temperature conditions. The others are specially designed for
temperature critical applications.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 5

Basic Electrical Lab 2010

Alpha-Numeric Code Identification

With the sizes of resistors and other components shrinking or changing in shape, it is getting difficult to
fit all of the color bands on a resistor. Therefore, a simpler alphanumeric coding system is used. This
method uses three numbers, sometimes followed by a single letter. The numbers represent the same as the
first three bands on a 4 band resistor. On the above SIL network, the 4 and 7 are the significant digits and
the 3 is the decade, giving 47 x 1000 or 47000 Ohms. The letter after the numbers is the tolerance. The
different representations are: M=20%, K=10%, J=5%, G=2%, F=1%.

Naming Convention

To simplify the writing of large resistor values, the abbreviations K and M are used for one thousand and
one million. To keep the convention standard, R is used to represent 0. Because of problems in seeing the
decimal point in some printed texts, the 3 letters: K M or R are used in place of the decimal point. Thus, a
2,700 Ohm resistor is written 2K7 and a 6.8 Ohm resistor is written 6R8.
The E12 Range
These identify a range of resistors that are know as "preferred values". In the E12 range there are 12
"preferred" or "basic" resistor values, and all of the others are simply decades of these values:
1.0, 1.2, 1.5, 1.8, 2.2, 2.7, 3.3, 3.9, 4.7, 5.6, 6.8 and 8.2

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 6

Basic Electrical Lab 2010

The table below lists every resistor value of the E12 range of preferred values. You will notice that there
are 12 rows containing the basic resistor values, and the columns list the decade values thereof. This
range most commonly covers standard carbon film resistors, which are not readily available in values
above 10 Megohms - 10M.
1R0 10R 100R 1K0 10K 100K 1M0 10M
1R2 12R 120R 1K2 12K 120K 1M2 n/a
1R5 15R 150R 1K5 15K 150K 1M5 n/a
1R8 18R 180R 1K8 18K 180K 1M8 n/a
2R2 22R 220R 2K2 22K 220K 2M2 n/a
2R7 27R 270R 2K7 27K 270K 2M7 n/a
3R3 33R 330R 3K3 33K 330K 3M3 n/a
3R9 39R 390R 3K9 39K 390K 3M9 n/a
4R7 47R 470R 4K7 47K 470K 4M7 n/a
5R6 56R 560R 5K6 56K 56OK 5M6 n/a
6R8 68R 680R 6K8 68K 680K 6M8 n/a
8R2 82R 820R 8K2 82K 82OK 8M2 n/a

The E24 Range

The E24 range of preferred values includes all of the E12 values, plus a further 12 to enable the
selection of more precise resistances. In the E24 range the preferred values are:
1.0, 1.1, 1.2, 1.3, 1.5, 1.6, 1.8, 2.0, 2.2, 2.4, 2.7, 3.0, 3.3, 3.6, 3.9, 4.3, 4.7, 5.1, 5.6, 6.2, 6.8, 7.5, 8.2 and 9.1

The table below lists every resistor value of the E24 range of preferred values. You will notice that there
are 24 rows containing the basic resistor values and the columns to the right list the decade values thereof.
This range most commonly covers metal film resistors which are not readily available in values above 1
Megohm - 1M0.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 7

Basic Electrical Lab 2010


1R0

10R

100R

1K0

10K

100K

1M0

1R1

11R

110R

1K1

11K

110K

n/a

1R2

12R

120R

1K2

12K

120K

n/a

1R3

13R

130R

1K3

13K

130K

n/a

1R5

15R

150R

1K5

15K

150K

n/a

1R6

16R

160R

1K6

16K

160K

n/a

1R8

18R

180R

1K8

18K

180K

n/a

2R0

20R

200R

2K0

20K

200K

n/a

2R2

22R

220R

2K2

22K

220K

n/a

2R4

24R

240R

2K4

24K

240K

n/a

2R7

27R

270R

2K7

27K

270K

n/a

3R0

30R

300R

3K0

30K

300K

n/a

3R3

33R

330R

3K3

33K

330K

n/a

3R6

36R

360R

3K6

36K

360K

n/a

3R9

39R

390R

3K9

39K

390K

n/a

4R3

43R

430R

4K3

43K

430K

n/a

4R7

47R

470R

4K7

47K

470K

n/a

5R1

51R

510R

5K1

51K

510K

n/a

5R6

56R

560R

5K6

56K

56OK

n/a

6R2

62R

620R

6K2

62K

620K

n/a

6R8

68R

680R

6K8

68K

680K

n/a

7R5

75R

750R

7K5

75K

750K

n/a

8R2

82R

820R

8K2

82K

82OK

n/a

9R1

91R

910R

9K1

91K

910K

n/a

There are also E48 and E96 tables, which have even more values. Resistors in these groups are less
common and tend to have a better tolerance rating.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 8

Basic Electrical Lab 2010


Power Rating
Type

Power Rating

Stability

Metal Film

Low at less than 3W

High 1%

Carbon

Low at less than 5W

Low 20%

Wirewound

High up to 500W

High 1%

Assignment:
Identify various resistance & Measure the resistance using color coding.
Record the readings in observation table.
Observation Table
S.No.

Type Of Resistance

Code no /Color Code

Decoding of Code

R(ohms)

Uses

Compare the results and verify them.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 9

Basic Electrical Lab 2010

Practical No 02

Identify various capacitors and understand their specifications

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 10

Basic Electrical Lab 2010

Objective:
To identify various Capacitor & measure their value using Color Code identification Method.

Equipments and components:


Electrolytic Capacitor, Axial wire Electrolytic Capacitor, Tantalum Capacitor, Ceramic Capacitor

Theory:
There are many different types of capacitors depending on the type of dielectric material used
between the two electrodes and the shape of the electrodes. The main types are electrolytic,
tantalum, mylar, ceramic and polyester capacitors as shown in Figure 3.

Figure 3: Capacitor Types (not to scale)


a. Electrolytic capacitors:
These are large capacitors both in volume and in capacitance value (tens of microfarads). They
look like a cylinder, as shown in Figure 3a. Electrolytic capacitors consist of a pair of aluminum
plates separated by borax paste electrolyte. This provides a large capacitance value in a relatively
small volume. Be careful when using these capacitors. They are polarized which means that the
capacitor is not symmetrical and that you can destroy it when putting a voltage of the wrong
polarity over it. As shown in Figure 3b, one of the terminals has a plus sign (with the largest leg)
(or minus sign - shortest leg) indicating that his terminal always has to be more positive
(negative) than the other one. If you violate this rule, the capacitor will be destroyed and may
even explode! Also capacitors have voltage ratings. Never put a larger voltage over the capacitor
than what is specified on the capacitor. This is also the case for all other capacitor types. Used
for all values above 0.1F. Electrolytic have lower accuracy and temperature stability than most
other types. It's usually best to only use an electrolytic when no other type can be used, or for all
Department Of Electronics & Telecommunication Engineering
Govt. Polytechnic Khargone

Page 11

Basic Electrical Lab 2010


values over 100F. Cheap electrolytic are usually made from plastic and rubber and therefore
melt easily during soldering.

b. Tantalum capacitor
These are smaller capacitors and can have different colors and have the shape of a deformed
oval. Tantalum capacitors are also polarized, as shown in Figure 3b. The positive terminal has
the longest leg and is usually marked by a plus sign. Tantalum capacitors pack a large capacity
into a relatively small and tough package compared to electrolytic, but pay for this in voltage
ratings. They are range from 0.1F to 100F.

c. Mylar capacitors
These are usually yellow cylinders. They are not polarized. A variation of polyester capacitors
used where price matters less than performance. High temperature stability and accuracy land
MKT capacitors in higher end audio circuits and power supplies. They range from 1nF to about
10F. (values over 1F are quite expensive)
d. Ceramic capacitors
These can have circular shapes (usually orange) or look like little boxes (often blue) as shown in
Figure 3d. Ceramic capacitors work well up to high frequencies in contrast to mylar capacitors.
While they are limited to quite small values, disc ceramics boast small and solid construction
with comparatively high voltage ratings. They range from 1pF to 0.47F and are not polarised.
This type can often be used to replace a polyester capacitor of the same value.

e. Polyester capacitors
These capacitors usually have a glossy cover and can have a square or oval shape. They are not
polarized. Ranging from 0.01F to 5F polyester capacitors have similar properties to disc
ceramics with some larger values and a slightly larger construction.
1.
2.
3.
4.
5.
6.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Disc Ceramic
Polyester "Green Caps":
MKT Polyester
Tantalum
Radial Electrolytic
Axial Electrolytic

Page 12

Basic Electrical Lab 2010

Reading capacitance
Reading capacitance values can be tricky and is generally more difficult than reading resistance
values. Here are some general guidelines. The unit of a capacitance is Farad. One Farad is a huge
capacitor (also in physical size). Capacitors are usually expressed in microfarads (x10-6F) for
large capacitors and picofarad (x10-12F) for small capacitors. The largest capacitance you will be
using ever is around 100 uF. Figure 3 gives a few examples to help you read capacitor values.
The value of the electrolytic capacitors in Figure 3a are 100 uF and 6.8uF (sometimes the unit u
may be omitted; however, we know that it cannot be picofarad as electrolytic capacitors usually
have large values). The values of the capacitors in Figure 3b are 22uF (with 25V rating) and
4.7uF (35V). An equivalent way of indicating the value is 226 (=22uF). The third digit indicates
106 x pF (or 226M = 22 x 106 x 10-12 = 22 uF). The M in 226 does NOT stand for Mega or milli
but refers to the tolerance (M = +/- 20%). The value of the capacitor in Figure 3c is 0.2uF (again,
M stands NOT for mega but for the tolerance). The value of the capacitor in Figure 3d is 20nF
(the 3rd digit is the power of 10: 203=20 x 103 x 10-12 = 20nF) with a 25V rating. Finally the
value of the capacitor in Figure 3e is 1uF (45 V).
The tolerance codes for capacitors are given in Table 1.
TABLE 1: Tolerance
Tolerance Code
M
K
J
G
F
D
C
B
A
Z

code of Capacitors
Value (+/- %)
20
10
5
2
1
0.5
0.25
0.1
0.05
0.025

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 13

Basic Electrical Lab 2010

Assignment:
Identify various Capacitors & Measure the capacitance using color coding.
Record the readings in observation table.
Observation Table
S.No.

Type Of Capacitor

Code no

Decoding of Code

C(pf/uF)
Voltage

Use of
Capacitor

Compare the results and verify them.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 14

Basic Electrical Lab 2010

Practical Number 03
Familiarization of Digital Multi meters and Analog Multi meters

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 15

Basic Electrical Lab 2010


Objective:
To measure voltage, current, and resistance using the Analog & Digital Multi meter and Verify
theoretically calculated results using basic network laws.
Equipments and components:
Variable Power Supply
Analog & Digital Multi meter
Resistors
Theory :
The digital multi meter
The hand-held digital multi meter is used widely to make electrical measurements Of
1. voltage dc & ac
2. current dc & ac
3. resistance
4. continuity
5. other quantities, such as frequency, depending on meters features
Input impedance:
In the voltage mode, the input impedance of a digital multi meter is usually high enough (several M)
that it has negligible effect on the circuit being measured.
Continuity check:
Many models allow you to check continuity, emitting an audible beep so that you dont need to look at
the meter while making the test.
Hooking up the meter:
Note that the meter is connected:
in parallel to measure voltage or resistance
in series to measure current.
See the figures to see how this is done.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 16

Basic Electrical Lab 2010

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 17

Basic Electrical Lab 2010

Analogue multi meter


Analogue multi meters, like digital ones have a variety of ranges. They are described in terms of Full
Scale Deflection or FSD. This is the maximum that the range can read. In order to get the best reading, it
is necessary to have the scale reading somewhere between about a quarter and all of the FSD. In this way
the optimum accuracy and significant number of figures can be read. As a result of this meters have a
variety of ranges, that may appear to be reasonably close to each other.
A typical meter may have the following ranges (note that the figures indicate the FSD):

DC Voltage: 2.5V, 10V, 25V, 100V, 250V, 1000V


AC voltage: 10V, 25V, 100V, 250V, 1000V
DC Current: 50uA, 1mA 10mW, 100mA
Resistance: R, 100R, 10 000R

There are several points to note from this typical analogue multi meter specification:
1. The low voltage AC voltage, and in this example the 10V AC range may have a different scale to
the others. The reason for this is that at low voltages a bridge rectifier is non-linear and this needs
to be taken into consideration. It is also for this reason that no 2.5V AC range was included.
2. The 1000V or 1kV ranges will often use a different input connection to enable the reading to be
taken through a different shunt and kept away from the rotary switch that may not be able to
handle a voltage this high.
3. AC current is often not included in the lower end meters because of the difficulties of undertaking
the measurement without a transformer to step up any voltage across a series sensing resistor for
rectification.
4. Batteries inside the multi meter are used to provide a current for the resistance measurements. No
other readings require the use of battery power - the meter is passive from that viewpoint.
5. The three resistance ranges of varying sensitivity multiply the meter reading by 1, 100, or 10 000
dependent upon the range. This allows for low resistance measurements to be made as well as
very high ones. Typically the higher resistance ranges may use a higher voltage battery than the
one used for the low resistance ranges.
Multimeter sensitivity
One of the specifications for an analogue multimeter is its sensitivity. This comes about because the meter
must draw a certain amount of current from the circuit it is measuring in order for the meter to deflect.
Accordingly the meter appears as another resistor placed between the points being measured. The way
this is specified is in terms of a certain number of Ohms (or more usually kOhms) per volt. The figure
enables the effective resistance to be calculated for any given range.
Thus if a multimeter had a sensitivity of 20 kOhms per volt, then on the range having a full scale
deflection of 10 volts, it would appear as a resistance of 10 x 20 kohms, i.e. 200 kohms.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 18

Basic Electrical Lab 2010


When making measurements the resistance of the meter should be at the very least ten times the
resistance of the circuit being measured. As a rough guide, this can be taken to be the highest resistor
value near where the meter is connected.
Normally the sensitivity of an analogue meter is much less on AC than DC. A meter with a DC
sensitivity of 20 kohms per volt on DC might only have a sensitivity of 1 kohm per volt on AC.
Multimeter operation
The operation of an analogue multimeter is quite easy. With a knowledge of how to make voltage, current
and resistance measurements , it is only necessary to know how to use the multi meter. If the meter is new
then it will obviously be necessary to install any battery or batteries needed for the resistance
measurements
.When using the meter it is possible to follow a number of simple steps:
1. Insert the probes into the correct connections - this is required because there may be a number of
different connections that can be used.
2. Set switch to the correct measurement type and range for the measurement to be made. When
selecting the range, ensure that the maximum range is above that anticipated. The range on the
multi meter can be reduced later if necessary. However by selecting a range that is too high, it
prevents the meter being overloaded and any possible damage to the movement of the meter
itself.
3. Optimise the range for the best reading. If possible adjust it so that the maximum deflection of the
meter can be gained. In this way the most accurate reading will be gained.
4. Once the reading is complete, it is a wise precaution to place the probes into the voltage
measurement sockets and turn the range to maximum voltage. In this way if the meter is
accidentally connected without thought for the range used, there is little chance of damage to the
meter. This may not be true if it left set for a current reading, and the meter is accidentally
connected across a high voltage point!

Schematic diagrams:
An ammeter measures current, a voltmeter measures the potential difference (voltage)
between two points, and an ohmmeter measures resistance. A multimeter combines these
functions and possibly some additional ones as well, into a single instrument.
The following diagrams show a multimeter can be used to measure current, voltage and
resistance:

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 19

Basic Electrical Lab 2010

Procedure:
1. To measure current, the circuit must be broken to allow the ammeter to be connected in series.
Ammeters must have a LOW resistance
2. To measure potential difference (voltage), the circuit is not changed: the voltmeter is connected in
parallel. voltmeters must have a HIGH resistance
3. An ohmmeter does not function with a circuit connected to a power supply. If you want to measure the
resistance of a particular component, you must take it out of the circuit altogether and test it separately.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 20

Basic Electrical Lab 2010


Assignment:
Measure the resistance using color coding and also measure voltage and
current of the circuit given theoretically. Implement the hardware ,& Measure voltage, current &
resistance using Analog & Digital Multi meter. Record the readings in observation table.

Observation Table
S.No

Using Color Codes & Basic


Using Digital Multimeter
Using Analog Multimeter
Calculations
R(ohms) I(Amp) V(Volts) R(ohms) I(Amp) V(Volts) R(ohms) I(Amp) V(Volts)

Compare the results and verify them.

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 21

Basic Electrical Lab 2010

Department Of Electronics & Telecommunication Engineering


Govt. Polytechnic Khargone

Page 22

You might also like