You are on page 1of 4

OKACONCRETE

INDUSTRIES
SDN.BHD.

a OKA ReadymixedConcreteplant is used to produce quality


square piles.
concrete for the productionof prestressed

I Prestressing wires before


concreting of OKA square
piles

Low and mediumrise buildings,


r Pedestrian and other short span bridges.

OKA-piles are manufacturedin


Factories.
a c c o r d a n c et o B S 8 1 1 0 a n d B S
8004. They are manufacturedto
Retainingwalls.
h i g hg r a d e . 1 2 5 m mx 1 2 5 m ma n d
15Omm x 150mm prestressed
r Laige drainsand culverts.
concrete square piles most suitable for the changingtrend in
Road and bridgeembankments.
building and civil engineering
rndustries.
Temporarystructures.
Havinga great demandfor quality
concrete piles towards light
engineeringstructures,it is most
suitable for replacing tropical
hardwood timber piles (Bakau
piles).
It is also more economicalas it
is proven to achieve higher
strengthto weight ratiocompared
to Reinforcedconcrete piles in
material,handling and driving
cost.
" prlesof othersizescanbe madeuponrequest.

Fully computerised batching


are
systems
installed and
applied tn OKA
Beadymixed
Concreteplant to
ensure accurate
batching and
concrete
of
quality.
superior

I. PRESTRESSIIIG
Longitudinalwires are stressed to between 70% and 80% of its characteristicbreaking
stress. Averageloss of prestressis 18%.
\
STREI{GTH for concrete is 60 N/mm 2'
2. CHARACTERISTIC
wires is 1770N/mm2.
3. BREAKING STRESS of prestressing
4. ALLOWABLE AXIAL WORKING LOAD
Normal conditionsfor actual load are based on soil conditions and should be
determined by load test. The normal allowable axial working load recommended
representsthe structuralcapacityof the piles.
5. PILE JOINT
P i l e s c o n r e sw i t h e n d p l a t e y o i n t i n g sa n d w e l d i n g sa r e r e q u i r e dt o e f f e c t t h e p i t e s
jointing.
6. LIFTING
OKA-pilesare provided with 2 lifting hooks incorporatedin the pile at 0.2 times of
the pile lengthfrom each end. Thibensuresminimumliftingstress.

OKA-piles being
used at site.

OKACONCRETE
INDUSTRIES
SDN.BHD.

125 x 125
6.0 & 3.0

Standard Le

Concrete CharacteristicStrength

(mm 2 )
(N/mmz )

Wires
Diameterof Prestressing
Diameterof Links
PrestressAfter Losses

(mm)
(mm)
(N/mmz )

Allowable Axial Working Load

(Tonnes)

SectionalArea

Wire
Prestressino
Cement
Aggregates
Admixture
Links
End Plates

BS 5896
u)

t1

1 5 0x 1 5 0
60 & 3.0

4.0 (4 nos) 5 . 0 ( 4 n o s )

PretensionedLogitudinalSteel
OrdinaryPortlandCemenl

BS 882

Washed Mining Sand/ 2Omm Granite

BS 5075
BS 4482
BS 4360

Super-Plasticizer
Spiral 4mm Dia. Hard Drawn Wires
Mild Steel Plates(Grade 43 A)

4 nos lommO
Anchorage
Bar

125mmx 125mm 150mmx 150mm

Bat (61)
Flat
Plate
l2

(mm)

d1

(mm)

d2

(mm)

Qt

(mm)

20

20

Az

( mm )

25

25

hj

(mm)

50

50

h2

(mm)

500

500

tI

(mm)

12

(mm)

-L

qX\

Ttt

.l
I

OKACONCRETE
INDUSTRIES
SDN.BHD.
(67634-tV)

50

CU

55

Allowablepile working load :


W = O.25 f",,- fp I Ac
where,
= Concretecharacteristic
strength
f .,,
=
Prestressafter losses
fp
= X-Sectional
area of pile
Ac

lpoh,Perak
Chateau,
OffPesiaran
Kampar,
30250
6,Lebuhraya
2531734,
2425212,
41,2411851,
2425211,
2425213
Iet.05-25427
Fax:
05-2532403
withoutnotice.Pleasecheck before
OKA Reservesthe rightto alterspecifications
r As a resultof productimprovements,
olacementof order.

You might also like