You are on page 1of 4

BIOMETRIC and BIO-MEDICAL based on Embedded System

WIRELESS POWER TRANSMISSION WITH SELFREGULATED OUTPUT VOLTAGE FOR BIOMEDICAL


IMPLANT
ABSTRACT:
An embedded system is characterized by real-time and multi-rate
operations define the ways in which the system works, reacts to events and
interrupts and schedules the systems functioning in real time. It does so by
following a plan to control latencies and to meet deadlines. The different
operations may take place at distinct rates.
The user of an embedded device is often not even aware that a computer is
present in the device. The computer is used primarily to provide flexibility and to
simplify the system design. Unlike a PC, program code is usually stored in ROM
and not a hard disk drive. Typically, the end user does not develop new software
for the embedded device. With advances in VLSI technology, embedded systems
have become so inexpensive that they are found in most of todays electronic
devices.
Since wireless power transfer technology (WPT) gains its popularity, broad
range of application and research are performed in the field of medical implantable
applications. In this paper, we review the technical status of WPT system applied
to medical implant devices.
As a practical application of this technology, the current achievements and
challenges of wireless capsule endoscopy are reviewed and analyzed, in view of its
design, functional requirement and related issues in WPT.

BIOMETRIC and BIO-MEDICAL based on Embedded System


WPT application to artificial heart is also discussed. Based upon the
analysis, we propose a research directions and WPT consideration in designing a
WPT system for implantable medical applications.

PROPOSED SYSTEM:
Here we are going to see Medical Implantable Applications
using WPT (Wireless Power Transfer). AC supply will be given HF (High
Frequency) Transformer, so that Transformer can produce high magnetic flex in the
primary side.
It will be transferred to secondary side and using filters it is given to DC
regulator with help of regulator, supply will be given to Microcontroller. And heart
sensor will find the rate of heart beat, ECG sensor will record the electrical activity
of heart and temperature sensor is used to find the temperature of the person and
the sensor values will display in the LCD and we can monitor these values by
themselves.

BIOMETRIC and BIO-MEDICAL based on Embedded System

BLOCK DIAGRAM:

WPT TRANSMITTER SECTION:


AC TO DC FILTERED
DC TO
HFAC
TRANSFORMAER
INVERTER
(AC 12V UPTO
40 KHZ)
HF PRIMARY
230V AC INPUT
SIDE

WPT RECEIVER AND PATIENT SECTION:


HF SECONDARY
DC REGULATOR
HF RECTIFICATION AND FILTERS
SIDE
(5V DC)

HEART BEAT SENSOR

ECG

LCD

ADC
PIC 16F877A

BODY
TEMPER
ATURE

BIOMETRIC and BIO-MEDICAL based on Embedded System


HARDWARE REQUIREMENTS
AC TO DC CONVERTER (STEP DOWN)
DC TO AC INVERTER WITH HIGH FREQUENCY (AC 12V UPTO
40KHZ)
INDUCTOR COIL
BRIDGE RECTIFIER
5V REGULATOR
MICROCONTROLLER
BLOOD PRESSURE SENSOR
LCD

SOFTWARE REQUIREMENTS
MPLAB IDE COMPILER.
KEIL COMPILER
PROTEUS SOFTWARE
VISUAL STUDIO

You might also like