FAT FILTERS
IMOS - OT
TECHNICAL CONDITIONS

TPI 2-06
The Product is protected by a utility pattern registered with the
Industrial Property Office

The present Technical Specifications determine sizes, properties, scope of application, and final
manufacture of fat filters. The Specifications apply to the design, ordering, production, acceptance,
delivery, and use of these products as of 1.11.2006. The present technical specifications replace
TPI 2-04.

I. GENERAL
Fat filters serve for air exhaust in the kitchen ventilation system and damp premises in the range of temperatures from 0C
up to 70C. They are designed to be mounted onto the duct, into the spigot or into the wall. The function of the fat filter
lies in capturing of finer fat aerosol particles from the exhausted air. They also can be provided with an air flow regulator.
Fat filters IMOS - OT are delivered:
- OTV - vertical mesh - more layer metal filter for vertical installation
- LOT - vertical with a two level filtration - more layer metal filter with a labyrinth-type filter
- OTH - horizontal mesh - more layer metal filter for horizontal installation
Functionality Description
Fat filters are designed as terminal elements for exhausting polluted air in performances, where the exhausted air contains
vapour, fat and other grease. They are being mounted onto the exhaust duct, where they separate impurities from the air.
The separator frame is fixed to the duct, as for OTH the separated grease is captured in an intercepting container, as for
OTV in an intercepting drain. The standard position of the intercepting drain is a = 90C, if necessary, the a angle can be
optional. It is easy to pull out and wash the separator collet (pic.6). Two level fat filters are designed for environments with
higher vapour concentration.
The OT separability depends on the composition of the polluted air and the exhaust velocity. Recommended velocities are
shown in graphs 1 and 2.
Engineering final manufacture

Fig. 1 Vertical mesh fat filter

Fig. 3 Vertical fat filter with a two level filtration

1 - metal filter - separator collet


2 - separator frame
3 - intercepting drain
4 - intercepting container

Fig. 2 Horizontal mesh fat filter

TPI 2-06

Material final manufacture


All parts of the fat filter are made from stainless steel

II. TECHNICAL REQUIREMENTS


Tab. 1 Main technical parameters of the fat filter
a
mm
325
425

525

625

b
mm
225
325
225
325
425
225
325
425
225
325
425

a1
mm
350
450

550

650

b1
mm
250
350
250
350
450
250
350
450
250
350
450

c
mm
75
95
95
115
115
95
115
135
95
115
135

Collet thickness
grid filter

OT V

labyrinth-type filter

15

1,1
1,3
1,3
1,5
1,7
1,5
1,7
1,9
1,7
1,9
2,1

15

OT H
kg
1,8
2,12
2,12
2,45
2,78
2,45
2,78
3,1
2,78
3,1
3,43

LOT
1,99
2,35
2,35
2,71
3,08
2,71
3,08
3,44
3,08
3,44
3,8

recommended area

Graph 1 Mesh fat filter pressure loss in clean state

one layer
labyrinth-type

recommended area

Graph 2 Two level fat filter and labyrinth-type fat filter pressure loss in clean state

TPI 2-06

Product ordering
The following data must be indicated in an order:
Designation:

IMOS - X X X - X x X - X

mesh fat filter

horizontal
vertical
two level labyrinth-type fat filter
grid collet
labyrinth-type collet

OTH
OTV
LOT
OT
OTL

* width (nominal dimension) [mm]


* height (nominal dimension) [mm]
regulator (from galvanized steel sheet)
regulator (from stainless steel)
fixing frame (for fixing into a wall
from galvanized steel sheet)
fixing frame (for fixing into a wall
from stainless steel)

a
b
R1, R3
RN1, RN3
UR
NUR

* opening dimensions are specified in chapter IV.


Order example:
mesh horizontal fat filter

12 pieces

TPI 2-06

mesh vertical fat filter with a regulation from galvanized sheet metal
IMOS-OTV - 525 x 325 - R1

4 pieces

TPI 2-06

mesh vertical fat filter with a regulation from stainless steel


IMOS-OTV - 525 x 325 - RN1

4 pieces

TPI 2-06

labyrinth-type two level fat filter


IMOS-LOT - 325 x 225

8 pieces

TPI 2-06

IMOS-OTL - 325 x 225

8 pieces

TPI 2-06

IMOS-OT - 325 x 225

8 pieces

TPI 2-06

labyrinth-type collet
netting collet

IMOS-OTH - 425 x 225

Product specifications
The following specifications are marked on the product or cover.
a) Company name and address
b) Product designation
c) TPI

III. CHECKING, ACCEPTANCE, AND WARRANTY


Product completeness and processing quality checks are provided by the manufacturer, who grants a 24 months warranty
for the product, commencing as of the dispatch date. The acceptance procedure is subject to the manufacturer's
generally binding directives. The fat filters OTH, OTV and LOT are delivered as assembled.

TPI 2-06

IV. ASSEMBLY AND MAINTENANCE


The IMOS / OTV, OTH and LOT assembly consists of:
- fixing in the duct wall fig. 4
- fixing into the wall fig. 5

Fig. 5 Fat filter assembly into a wall with UR

Fig. 4 Fat filter assembly on a duct

Fig. 6 Disassembling of LOT fat filter collet


Maintenance of IMOS - OTV, OTH and LOT :
Apart from common cleaning, it is not necessary to perform any maintenance during the operating life of the fat filter.
Cleaning:
It is possible to clean the fat filter collet in a dishwasher or manually. We recommend to use a detergent for stainless
dishes. The recommended washing temperature in a dishwasher is up to 60C, when cleaning manually the collet has to
be soaked in warm detergent water of ca. 50C and cleaned with a brush after 15 minutes.

V. PACKAGING, TRANSPORTATION AND STORAGE


The products IMOS - OTV, OTH and LOT are delivered in paper boxes or non-standard sizes in PVC foil; the customer
is required to deliver such cover to a waste disposal or recycling facility at his expense. Transportation to a customer is
organised with the use of ordinary means of transport, and the cost is also to be borne by the customer. It is recommended that products are kept in an enclosed and dry place.

VI. APPENDIX
Any deviations from the present technical specifications are subject to agreement with the manufacturer. Vrobca si
vyhradzuje prvo na technick zmeny bez predchdzajceho upozornenia driteov tchto TPI.
Svisiace normy: CR 12792 (12 001) Vetranie budov. Nzvoslovie
STN EN 1505 Vetranie budov. Kovov plechov potrubie a tvarov kusy tvorhrannho prierezu.
Rozmery

TPI 2-06

You might also like