Professional Documents
Culture Documents
1 9 6 5
2 0 1 5
50 Ye a r s Th erm al Ma nag e me nt
SoliTherm
Control Ca bi n e t A i r C onditioning
www.seifertsystems.com
Ta b l e o f Co n t e n t s
Pa g e
S ol i Therm C omP ac t
5 - 6
7 - 8
S ol i Therm 19 R ac k & To p mo u n t
S ol i Therm S li m Line
11 - 1 2
S ol i Therm C ool M at c h
13
15
17 - 18
19
KG 4310
1,000 W
KG 4315
1,500 W
KG 4320
2,000 W
KG 4325
2,500 W
KG 4330
3,000 W
KG 4340
4,000 W
KG 4266
320 W
KG 4267
400 W
KG 4268
400 W
KG 4269
500 W
KG 4270
600 W
KG 4271
820 W
KG 4272
1,100 W
KG 4274
1,500 W
KG 2019
520 W
KG 2020
520 W
KG 2025
520 W
KG 2002
520 W
KG 4482
450 W
KG 4555
1,100 W
KG 4533
550 W
KG 4534
850 W
KG 4535
900 W
OC 5705
550 W
OC 5708
750 W
OC 5709
850 W
OC 5710
1,000 W
OC 5715
1,500 W
OC 5720
2,000 W
OC 5725
2,500 W
OC 5730
3,000 W
OC 5740
4,000 W
19
850 W
Dimensions
TOP
KG 4309
Recess
750 W
Int
KG 4308
Ext
550 W
Mounting
48 V
KG 4305
24 V
320 W
460 V
KG 4304
400 V
L35L35
120 V
Type
Rated voltage
230 V
Page
( H x W x D ) mm
500 x 280 x 200
5/7
5/7
5/7
5/7
6/8
6/8
6/8
6/8
6/8
11
11
11
11
12
12
12
12
3U x 19 x 564.5
13
3U x 19 x 19
13
310 x 475 x 98
13
13
17
17
17
17
18
18
18
18
18
15
15
15
15
15
15
50 W
TG 3102
100 W
TG 3152
150 W
TG 3152
175 W
TG 3200
200 W
TG 3200
250 W
SoliTherm ComPact
Reliability and user friendliness are the best ways to describe the electronic controller being used in the
ComPact air conditioners. The display indicates temperature and operating status and can be easily set
a n d a d j u s t e d b y t h e u s e r v i a a To u c h P a d .
A complete model range from 320 W up to 4kW with simple operation were the key ideas during the development.
We have also placed a strong emphasis in standardizing components, versions and sizes thus diminishing the
need of large spare part stocks, complex training or long unit selection processes.
All ComPact units have a powder coated mild steel housing (RAL 7035). For applications were hygiene and corrosion
protection are required, we offer a stainless steel cover for all ComPact models. Units with a cooling capacity
of 2 kW and above can be optionally supplied with an electric condensate evaporator.
For a universal use of our ComPact units we offer also models for recessed mounting. The available recessed
depth (A) varies from 30mm to 120mm. The part numbers XXXXXX81 have a standard depth of 90mm. Kindly
contact us for other models and part numbers.
UL Type12
SoliTherm C omPact
Part-no.
Cooling capacity
L35L35 / L35L50 (DIN3168)
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
320 W / 200 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
18
320 W / 240 W
120 V - 60 Hz
+20C - +55C
24 / 54
26
43042001
320 W / 240 W
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
26
Click here
for full
technical
specifications
KG 4304
550 W / 410 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
27.7
43051001
550 W / 410 W
120 V - 60 Hz
+20C - +55C
24 / 54
33.7
43052001
550 W / 410 W
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
33.7
43080001
750 W / 470 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
27.7
43081001
750 W / 480 W
120 V - 60 Hz
+20C - +55C
24 / 54
33.7
43082001
750 W / 480 W
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
33.7
43090001
850 W / 610 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
30
43091001
850 W / 600 W
120 V - 60 Hz
+20C - +55C
24 / 54
36
43092001
850 W / 600 W
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
36
43100001
1 kW / 660 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
30
43101001
1 kW / 660 W
120 V - 60 Hz
+20C - +55C
24 / 54
36
43102001
1 kW / 720 W
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
36
Click here
for full
technical
specifications
KG 4305
Click here
for full
technical
specifications
KG 4308
Click here
for full
technical
specifications
KG 4309
Click here
for full
technical
specifications
KG 4310
Note: The IP rating on the ambient side can be increased by using filter mats
www.seifertsystems.com
UL Type12
SoliTherm C omPact
Cooling capacity
Part-no.
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
1.50 kW / 1.22 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
39.7
43151001
1.50 kW / 1.22 kW
120 V - 60 Hz
+20C - +55C
24 / 54
47.7
43152001
1.50 kW / 1.22 kW
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
47.7
43200001
2 kW / 1.6 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
44.2
43201001
2 kW / 1.6 kW
120 V - 60 Hz
+20C - +55C
24 / 54
50
43202001
2 kW / 1.63 kW
400/460 V - 50/60 Hz 3~
+20C - +55C
24 / 54
44.2
Click here
for full
technical
specifications
KG 4315
Click here
for full
technical
specifications
KG 4320
2.5 kW / 1.97 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
67.5
43251001
2.5 kW / 1.97 kW
120 V - 60 Hz
+20C - +55C
24 / 54
73
43252001
2.5 kW / 1.97 kW
400/460 V - 50/60 Hz 3~
+20C - +55C
24 / 54
73
43300001
3 kW / 2.38 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
67.5
43301001
3 kW / 2.42 kW
120 V - 50/60 Hz
+20C - +55C
24 / 54
75
43302001
3 kW / 2.39 kW
400/460 V - 50/60 Hz 3~
+20C - +55C
24 / 54
72.5
43400001
4 kW / 3.18 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
69
43402001
4 kW / 3.17 kW
400/460 V - 50/60 Hz 3~
+20C - +55C
24 / 54
72.5
Note: The IP rating on the ambient side can be increased by using filter mats
www.seifertsystems.com
Click here
for full
technical
specifications
KG 4325
Click here
for full
technical
specifications
KG 4330
Click here
for full
technical
specifications
KG 4340
Cooling capacity
L35L35 / L35L50 (DIN3168)
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
550 W / 410 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
27.7
43051081
550 W / 410 W
120 V - 60 Hz
+20C - +55C
24 / 54
33.7
43052081
550 W / 410 W
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
33.7
43080081
750 W / 470 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
27.7
43081081
750 W / 480 W
120 V - 60 Hz
+20C - +55C
24 / 54
33.7
43082081
750 W / 480 W
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
33.7
43090081
850 W / 610 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
30
43091081
850 W / 600 W
120 V - 60 Hz
+20C - +55C
24 / 54
36
43092081
850 W / 600 W
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
36
43100081
1 kW / 660 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
30
43101081
1 kW / 660 W
120 V - 60 Hz
+20C - +55C
24 / 54
36
43102081
1 kW / 720 W
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
36
Click here
for full
technical
specifications
KG 4305
Click here
for full
technical
specifications
KG 4308
Click here
for full
technical
specifications
KG 4309
Click here
for full
technical
specifications
KG 4310
Note: The IP rating on the ambient side can be increased by using filter mats
www.seifertsystems.com
Part-no.
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
1.5 kW / 1.22 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
39.7
43151081
1.5 kW / 1.22 kW
120 V - 60 Hz
+20C - +55C
24 / 54
47.7
43152081
1.5 kW / 1.22 kW
400/460 V - 50/60 Hz 2~
+20C - +55C
24 / 54
47.7
43200081
2 kW / 1.6 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
44.2
43201081
2 kW / 1.6 kW
120 V - 60 Hz
+20C - +55C
24 / 54
50
43202081
2 kW / 1.63 kW
400/460 V - 50/60 Hz 3~
+20C - +55C
24 / 54
44.2
Click here
for full
technical
specifications
KG 4315
Click here
for full
technical
specifications
KG 4320
2.5 kW / 1.97 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
67.5
43251081
2.5 kW / 1.97 kW
120 V - 60 Hz
+20C - +55C
24 / 54
73
43252081
2.5 kW / 1.97 kW
400/460 V - 50/60 Hz 3~
+20C - +55C
24 / 54
73
43300081
3 kW / 2.38 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
67.5
43301081
3 kW / 2.42 kW
120 V - 50/60 Hz
+20C - +55C
24 / 54
75
43302081
3 kW / 2.39 kW
400/460 V - 50/60 Hz 3~
+20C - +55C
24 / 54
72.5
43400081
4 kW / 3.18 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
69
43402081
4 kW / 3.17 kW
400/460 V - 50/60 Hz 3~
+20C - +55C
24 / 54
72.5
Note: The IP rating on the ambient side can be increased by using filter mats
www.seifertsystems.com
Click here
for full
technical
specifications
KG 4325
Click here
for full
technical
specifications
KG 4330
Click here
for full
technical
specifications
KG 4340
UL Type12
Cooling capacity
L35L35 / L35L50 (DIN3168)
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
Click here
for full
technical
specifications
450 W / 280 W
230 V - 50/60 Hz
+20C - +50C
24 / 54
23
44821001
450 W / 280 W
120 V - 60 Hz
+20C - +50C
24 / 54
23
KG 4482
1.1 kW / 700 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
55
45551001
1.1 kW / 700 W
120 V - 60 Hz
+20C - +55C
24 / 54
55
45552001
1.1 kW / 700 W
400/460 V - 50/60 Hz 3~
+20C - +55C
24 / 54
55
Click here
for full
technical
specifications
KG 4555
19 Rack mounted
45330001
550 W / 370 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
28
Click here
for full
technical
specifications
KG 4533
45340001
850 W / 590 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
33
Click here
for full
technical
specifications
KG 4534
4535000
900 W / 700 W
230 V - 50/60 Hz
+20C - +55C
24 / 44
45
4535100
900 W / 700 W
120 V - 60 Hz
+20C - +55C
24 / 44
45
Click here
for full
technical
specifications
KG 4535
www.seifertsystems.com
SoliTherm SlimLine |
filte r le s s te c h n o l ogy f or m or e s af et y
Maximum power to size ratio this characterises the SlimLine air conditioners. Compatibility with market standards ensures the
customer an easy integration with his enclosure or cabinet systems. SlimLine air conditioners a re d es i g ne d to o pe ra te wi th ab s ol ute l y
m ini mum ma in te n a n c e . T hey ar e ec o- f r i endl y and do not n e e d d i r t co l l e cti n g fi l te r m a ts.
The opti mis e d wid e - r ib bed al um i ni um c ondens er pr ovi d e s i m p r o ve d co o l i n g p e r fo r m a n ce a n d e n su r e s r e l i a b i l i ty in industrial
operati ons . Hig h q u a lity c om ponent s f or m t he bas i s f or th e sm o o th r u n n i n g a n d l o n g w o r ki n g l i fe o f th e Sl i m L i n e a i r conditioners.
T h e u n i t s c a n b e e x t e r n a l l y o r i n t e r n a l l y m o u n t e d a n d a r e o n l y 11 0 m m d e e p a n d t h e r e f o r e c u r r e n t l y t h e s l i m m e s t a i r c o n d i t i o n e r
on the market. With recessed mounting the units will only be 25mm out of the cabinet wall. As only small apertures need to
be cut for mounting, the cabinet doors remain stable.
As an optio n , a ll S limL ine m odel s c an be upgr aded w i t h a m a ste r / sl a ve fu n cti o n w h i ch a l l o w s to co n n e ct u p to 2 0 units together,
a d i s p l a y, a n IP a d d r e s s , the possibility to download operational data and a USB connection.
By addi ng a NEMA COV E R K I T m ade of V 2A ( A I S I 304/ 1 .4 3 0 1 ) to yo u r e xi sti n g o r n e w Sl i m L i n e co o l i n g u n i ts, th e y ca n be upgraded
to pas s th e s tr ic t NE MA 4x ( I P 56) r at i ng. I n t hi s w ay, th e u n i ts a r e su i ta b l e fo r th e fo o d i n d u str y a n d o u td o o r a p p l i cations where
requirem e n ts a g a in s t h o se w at er and i ngr es s pr ot ec t i on a r e n e ce ssa r y. Wi th h i g h e r a m b i e n t te m p e r a tu r e s, th e co o l i n g capacity can
be reduc e d b y a p p r o x ima t el y 10% .
Dimension
(H x W x D) mm
S/M5930017544
KG 4266
S/M5930018050
KG 4268
S/M5930017545
KG 4269
S/M5930019506
KG 4270
S/M5930018030
KG 4271
S/M5930019200
KG 4272
S/M5930016726
KG 4274
10
www.seifertsystems.com
UL Type12
SoliTherm SlimLine
Part-no.
Cooling capacity
L35L35 / L35L50 (DIN3168)
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
Click here
for full
technical
specifications
320 W / 140 W
230 V - 50/60 Hz
+20C - +50C
24 / 54
13
42661001
320 W / 140 W
120 V - 60 Hz
+20C - +50C
24 / 54
13
KG 4266
400 W / 195 W
230 V - 50/60 Hz
+20C - +50C
24 / 54
14.8
42671001
400 W / 195 W
120 V - 60 Hz
+20C - +50C
24 / 54
14.8
Click here
for full
technical
specifications
KG 4267
400 W / 155 W
230 V - 50/60 Hz
+20C - +50C
24 / 54
14.8
42681001
400 W / 155 W
120 V - 60 Hz
+20C - +50C
24 / 54
14.8
Click here
for full
technical
specifications
KG 4268
500 W / 160 W
230 V - 50/60 Hz
+20C - +50C
24 / 54
15.8
42691001
500 W / 160 W
120 V - 60 Hz
+20C - +50C
24 / 54
15.8
Click here
for full
technical
specifications
KG 4269
www.seifertsystems.com
11
UL Type12
SoliTherm SlimLine
Cooling capacity
Part-no.
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
600 W / 300 W
230 V - 50/60 Hz
+20C - +50C
24 / 54
30
42701001
600 W / 300 W
120 V - 60 Hz
+20C - +50C
24 / 54
30
42702001
600 W / 300 W
400/460 V - 50/60 Hz 2~
+20C - +50C
24 / 54
33
24 / 54
33
Click here
for full
technical
specifications
KG 4270
820 W / 480 W
230 V - 50/60 Hz
+20C - +55C
42711001
820 W / 480 W
120 V - 60 Hz
+20C - +55C
24 / 54
34
42712001
820 W / 480 W
380/415 V - 50 Hz 3~
400/460 V - 60 Hz 3~
+20C - +55C
24 / 54
38
Click here
for full
technical
specifications
KG 4271
1.1 kW / 710 W
230 V - 50/60 Hz
+20C - +55C
24 / 54
44
42721001
1.1 kW / 710 W
120 V - 60 Hz
+20C - +55C
24 / 54
44
42722001
1.1 kW / 710 W
380/415 V - 50 Hz 3~
400/460 V - 60 Hz 3~
+20C - +55C
24 / 54
45
Click here
for full
technical
specifications
KG 4272
1.5 k / 1.2 kW
230 V - 50/60 Hz
+20C - +55C
24 / 54
50
42741001
1.5 k / 1.2 kW
120 V - 60 Hz
+20C - +55C
24 / 54
50
42742001
1.5 k / 1.2 kW
380/415 V - 50 Hz 3~
400/460 V - 60 Hz 3~
+20C - +55C
24 / 54
55
12
www.seifertsystems.com
Click here
for full
technical
specifications
KG 4274
SoliTherm CoolMatch |
The ultra-compact and lightweight air conditioners are specially designed for small enclosures with limited mounting areas. They
c a n b e m o u n t e d e x t e r n a l l y, r e c e s s e d o r m o u n t e d i n t o a 1 9 r a c k w i t h o n l y 3 U u n i t h e i g h t .
The compact compressor with its variable speed, can be set to provide only the cooling power which is actually needed.
The constant adjustment results in a very uniform temperature level within the cabinet and therefore stresses the electrical
components and the cooling significantly less. This results in higher safety and longer life cycle. In addition, the condensation
inside the cabinet is minimized. The CoolMatch Series sets new performance-to-size standards which makes it particularly
suitable for applications such as battery cooling. In case of emergency the DC operation allows the unit to be battery operated.
All this comes with significant energy savings!
Part-no.
Cooling capacity
L35L35 / L35L50 (DIN3168)
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
19 Rack mounted
20190240
520 W / 380 W
24 V DC
+10C - +55C
22 / 54
20190480
520 W / 380 W
48 V DC
+10C - +55C
22 / 54
Click here
for full
technical
specifications
KG 2019
19 Rack mounted
20200240
520 W / 380 W
24 V DC
+10C - +55C
22 / 54
8.6
20200480
520 W / 380 W
48 V DC
+10C - +55C
22 / 54
8.6
Click here
for full
technical
specifications
KG 2020
520 W / 380 W
24 V DC
+10C - +55C
22 / 54
7.9
20250480
520 W / 380 W
48 V DC
+10C - +55C
22 / 54
7.9
Click here
for full
technical
specifications
KG 2025
520 W / 380 W
24 V DC
+10C - +55C
22 / 54
7.2
20020480
520 W / 380 W
48 V DC
+10C - +55C
22 / 54
6.8
Click here
for full
technical
specifications
KG 2002
www.seifertsystems.com
13
SoliTherm Peltier
The inno v a tiv e Pe ltie r ther m oel ec t r i c t ec hnol ogy pr ov i d e s a n e ffe cti ve co o l i n g so l u ti o n vi r tu a l l y m a i n te n a n ce fr e e . The SoliTherm
Pel tier air c o n d itio n e r s i nc or por at e t he t ec hnol ogy w i t hin a sl e e k a n d m o d e r n d e si g n r a n g i n g fr o m 5 0 W to 2 5 0 W.
Thermoelectric elements create a temperature difference between the internal and ambient heat sinks, making i n terna l ai r c oo l e r wh i l e
dis s ipatin g th e h e a t o u t t o t he ex t er nal env i r onm ent . Fans help the transfer of convective h e a t fr o m th e h e a t si n ks, w h i ch are optimised
for maximu m flo w.
Thes e ai r c o n d itio n e r s com e i n pow der - c oat ed s heet s t e e l o r sta i n l e ss ste e l h o u si n g s a cco r d i n g to cu sto m e r s r e q u i r ements. They
can be mo u n te d in a n y pos i t i on bec aus e t hes e uni t s do n t h a ve a co m p r e sso r.
Pleas e no te th a t th e in tegr at ed c ondens at i on m anagem e n t m a y va r y d e p e n d i n g o n th e m o u n ti n g si tu a ti o n .
Sol iTherm Pe ltie r c o o lin g uni t s ar e r es i s t ant t o ex t r em e a m b i e n t co n d i ti o n s a n d ca n o p e r a te e ffe cti ve l y e ve n i n e n vi r onments which
are dusty a n d o ily a n d w her e t em per at ur es m ay v ar y f r o m - 2 0 C to 6 5 C . Th e y co m p l y w i th Eu r o p e a n sta n d a r d s IEC/TC 62610-1
and IEC /T C 6 2 6 1 0 - 3 , a n d c an be us ed bot h f or i ndoor a n d o u td o o r a p p l i ca ti o n s.
C ontrol le r s a n d th e r mo s t at s f or P el t i er uni t s ar e av ai l ab l e o n r e q u e st
14
UL Type12
SoliTherm Peltier
Part-no.
Cooling capacity
L35L35
Voltage / Frequency
Operating
temp. range
Ingress IP
protection
Weight (Kg)
QR Code
50 W
24 V DC
-20C - +65C
IP 66
3.3
IP 66
3.9
IP 66
5.9
IP 66
7.4
50 W
24 V DC
-20C - +65C
Click here
for full
technical
specifications
TG 3050
100 W
24 V DC
-20C - +65C
100 W
24 V DC
-20C - +65C
Click here
for full
technical
specifications
TG 3102
150 W
24 V DC
-20C - +65C
IP 66
3152308
175 W
48 V DC
-20C - +65C
IP 66
3200303
200 W
24 V DC
-20C - +65C
IP 66
3200308
250 W
48 V DC
-20C - +65C
IP 66
Click here
for full
technical
specifications
TG 3152
Click here
for full
technical
specifications
TG 3200
150 W
24 V DC
-20C - +65C
IP 66
12.7
3152310
175 W
48 V DC
-20C - +65C
IP 66
12.7
3200305
200 W
24 V DC
-20C - +65C
IP 66
12.7
3200310
250 W
48 V DC
-20C - +65C
IP 66
12.7
Click here
for full
technical
specifications
TG 3152
Click here
for full
technical
specifications
TG 3200
www.seifertsystems.com
15
SoliTherm Outdoor
Outdoor conditions can be harsh on control cabinets, therefore our units are thoroughly designed to protect your
cabinets against any ingress of foreign solid and/ or liquid material that could potentially damage the sensitive
electronic components.
The high fin separation nanocoated condenser requires almost no maintenance and service. Our wall mounted cooling
units operate between -20C and 55C. An optional heater kit is available to heat the internal cabinet temperature
when necessary.
All SoliTherm Outdoor cooling units are equipped with our new electronic controller, which
constantly monitors the pre-set cabinet temperature. Depending on the temperature and the power
loss inside the cabinet, the cooling or heating circuits will be switched on and off accordingly.
Energy saving and extended component life are the positive effects. The SoliTherm Outdoor range offers cooling
capacities from 550 W up to 4 kW and has as a standard IP 56 rating towards the cabinet (NEMA 12, 3, 3R, 4, 4X).
Full stainless steel versions even meet the NEMA 4X requirements. All units come with a cover in mild steel, powder
coated (RAL 7035). Optional stainless steel covers are available for improved corrosion protection.
16
www.seifertsystems.com
SoliTherm Outdoor
Part-no.
Cooling capacity
L35L35 / L35L50 (DIN3168)
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
550 W / 410 W
230 V - 50/60 Hz
-20C - +55C
IP 56
30
570510001
550 W / 410 W
120 V - 60 Hz
-20C - +55C
IP 56
35
570520001
550 W / 410 W
400/460 V - 50/60 Hz 2~
-20C - +55C
IP 56
35
570800001
750 W / 470 W
230 V - 50/60 Hz
-20C - +55C
IP 56
30
570810001
750 W / 480 W
120 V - 60 Hz
-20C - +55C
IP 56
35
570820001
750 W / 480 W
400/460 V - 50/60 Hz 2~
-20C - +55C
IP 56
35
570900001
850 W / 610 W
230 V - 50/60 Hz
-20C - +55C
IP 56
32
570910001
850 W / 600 W
120 V - 60 Hz
-20C - +55C
IP 56
37
570920001
850 W / 600 W
400/460 V - 50/60 Hz 2~
-20C - +55C
IP 56
37
IP 56
38
Click here
for full
technical
specifications
OC 5705
Click here
for full
technical
specifications
OC 5708
Click here
for full
technical
specifications
OC 5709
1 kW / 660 W
230 V - 50/60 Hz
-20C - +55C
571010001
1 kW / 660 W
120 V - 60 Hz
-20C - +55C
IP 56
45
571020001
1 kW / 720 W
400/460 V - 50/60 Hz 2~
-20C - +55C
IP 56
45
Click here
for full
technical
specifications
OC 5710
www.seifertsystems.com
17
UL Type12, 3, 3R, 4, 4X
SoliTherm Outdoor
Cooling capacity
Part-no.
Voltage / Frequency
Operating
temp. range
IP protection to
IEC 60 529 Ext/ Int
Weight (Kg)
QR Code
1.5 kW / 1.22 kW
230 V - 50/60 Hz
-20C - +55C
IP 56
48
571510001
1.5 kW / 1.22 kW
120 V - 60 Hz
-20C - +55C
IP 56
55
571520001
1.5 kW / 1.22 kW
400/460 V - 50/60 Hz 2~
-20C - +55C
IP 56
55
572000001
2 kW / 1.6 kW
230 V - 50/60 Hz
-20C - +55C
IP 56
49
572010001
2 kW / 1.6 kW
120 V - 60 Hz
-20C - +55C
IP 56
53
572020001
2 kW / 1.63 kW
400/460 V - 50/60 Hz 3~
-20C - +55C
IP 56
50
IP 56
68
Click here
for full
technical
specifications
OC 5715
Click here
for full
technical
specifications
OC 5720
2.5 kW / 1.97 kW
230 V - 50/60 Hz
-20C - +55C
572510001
2.5 kW / 2 kW
120 V - 60 Hz
-20C - +55C
IP 56
75
572520001
2.5 kW / 2 kW
400/460 V - 50/60 Hz 3~
-20C - +55C
IP 56
75
573000001
3 kW / 2.4 kW
230 V - 50/60 Hz
-20C - +55C
IP 56
70
573010001
3 kW / 2.4 kW
120 V - 60 Hz
-20C - +55C
IP 56
78
573020001
3 kW / 2.4 kW
400/460 V - 50/60 Hz 3~
-20C - +55C
IP 56
75
574000001
4 kW / 3.3 kW
230 V - 50/60 Hz
-20C - +55C
IP 56
72
574020001
4 kW / 3.3 kW
400/460 V - 50/60 Hz 3~
-20C - +55C
IP 56
72
18
www.seifertsystems.com
Click here
for full
technical
specifications
OC 5725
Click here
for full
technical
specifications
OC 5730
Click here
for full
technical
specifications
OC 5740
Seif e rt
| T herm a l Ma n a g e me n t So lu tio n s
A ir / Wat er Heat Ex c h a n g e r s
Our c o mp a c t a ir / wat er heat ex c hanger s c an be use d i f a co l d w a te r su p p l y i s a va i l a b l e .
Seifer t h e a t e x c h a n g e r s ar e av ai l abl e as 19 pl ug- i n m o d e l s w i th m i n i m a l d e p th , a s i n te r n a l ,
and a s to p a n d s id e m ount i ng v er s i ons . T hes e i ndu str y p r o ve n h e a t e xch a n g e r s d i ssi p a te
from 7 0 0 W u p to 5 .5 k W (L 35 W1 0). W i t h o u r m o d u l a r s y s t e m s e t u p w e c a n e v e n r e a c h
p e r f o r m a n c e s o f u p t o 4 0 k W.
A ir / A i r Heat E xch a n g e r s
Our co u n te r flo w a n d c r os s f l ow heat ex c hanger s ar e d e si g n e d b o th fo r o u td o o r a n d i n d o o r
appl ic a tio n s . T h e S ei f er t hi gh- end v ac uum br az i n g te ch n o l o g y i s b e st- i n - cl a ss th e r m a l
d i s s i p a t i o n a n d th e m os t c om pac t f oot pr i nt i n t he i n d u str y. Th e y co m p l y w i th th e N EM A a n d
I P r e q u i re m e n ts . Our customers can also opt for ultimate corrosion protection and chromated
aluminium surfaces.
F il te r f ans
Fi lter fa n s a r e u s e d if t he des i r ed c abi net t em per at u r e ca n b e co n sta n tl y a b o ve th e a m b i e n t
ai r temp e r a tu r e . In c o m bi nat i on w i t h t her m os t at s f r o m Se i fe r t yo u ca n sa ve o n e n e r g y si n ce
the fan is o n ly o n when ac t ual l y needed, on m at er i al b e ca u se o f l e ss co n su m p ti o n o f fi l te r
mats a n d o n time s in c e l es s c l eani ng i s r equi r ed. A l l th i s w i l l e n su r e a l o n g e r l i fe ti m e o f th e
filter fa n s a n d will e nhanc e y our pr oc es s r el i abi l i t y a n d sa fe ty. Al l o u r fi l te r fa n s a r e a l so
avai la b le in E MC a n d N E M A 3R v er s i ons .
www.seifertsystems.com
19
75 Circuit Drive
North Kingstown
RI 02852
USA
Tel. +1 401-294-6960
Fax +1 401-294-6963
info.de@seifertsystems.com
info.us@seifertsystems.com info@seifertsystems.com.au
info@seifertsystems.com
Seifert Systems AG
info.ch@seifertsystems.com
0 3 / 2 0 1 5 S e i fe r t S ys t e m s / D oc n o. 5 9 6 0 0 5 2 9 9