Maintenance Manual
ZTE Corporation
ZXG10-BTS (V1A)
Maintenance Manual
*
Preface
ZXG10, a GSM mobile communication system independently developed by ZTE Corporation, is
composed of the switching sub-system ZXG10-MSS and the base station sub-system ZXG10-BSS.
The ZXG10-BSS is in charge of providing and managing wireless transmission in GSM, and is
composed of the base station controller ZXG10-BSC and the base station transceiver ZXG10-BTS,
etc. The reliable running of the ZXG10-BSS on the network is closely related to correct operation
and maintenance. Therefore, it is very important to handle problems properly with correct methods.
The ZXG10-BTS (V1A) Maintenance Manual serves as a guide for the user to perform daily
maintenance and fault handling on ZXG10-BTS (V1A). This manual primarily introduces the daily
maintenance, alarm handling and operation information processing of ZXG10-BTS (V1A).
In this Manual, ZXG10-BTS (V1A) is abbreviated as BTS (V1A) or BTS; ZXG10-BTS (V1A) local
management terminal as LMT; ZXG10-BSS (V1A) as BSS; and ZXG10-BSC (V1A) as BSC (V1A)
or BSC.
This Manual includes three chapters: Chapter 1 introduces the routine maintenance and emergent
maintenance of the ZXG10-BTS (V1A) as well as frequently used maintenance methods. Chapter 2
introduces the alarm classification of the LMT of ZXG10-BTS (V1A) and describes in detail the
alarm code, alarm content, alarm level, alarm cause, alarm impact, time limit of handling, and
handling process. Chapter 3 itemizes the operation information and handling methods of the boards
such as OMU and TRU. Appendix A introduces the procedures and precautions for replacing parts
and boards. Appendix B gives a list of abbreviations used in this document for the convenience of
users in reading this Manual.
This set of manuals also consists of the following documents:
Technical Manual for ZXG10-BTS (V1A)
Installation Manual for ZXG10-BTS (V1A)
Operation Manual for ZXG10-BTS (V1A)
Statement: The actual product may differ from what is described in this manual due to
frequent updates of ZTE products and fast development of technologies. Please contact our
local office for updating/upgrading information of the product.
Contents
1 EQUIPMENT MAINTENANCE..........................................................................................................1
1.1 MAINTENANCE DESCRIPTION.......................................................................................................................1
1.2 ROUTINE MAINTENANCE.............................................................................................................................2
1.2.1 Daily routine maintenance...........................................................................................................2
1.2.2 Regular routine maintenance.......................................................................................................4
1.3 EMERGENT MAINTENANCE..........................................................................................................................5
1.4 TYPICAL MAINTENANCE METHODS...............................................................................................................6
1.5 RELEVANT MAINTENANCE TABLES................................................................................................................7
1.5.1 Routine maintenance and operation record table .......................................................................7
1.5.2 Emergent maintenance and operation record table ..................................................................10
2 ALARM HANDLING...........................................................................................................................11
2.1 ALARM INFORMATION AND CLASSIFICATION.................................................................................................11
2.2 LEVEL-1 ALARM....................................................................................................................................18
2.3 LEVEL- 2 ALARM...................................................................................................................................18
2.3.1 Alarm of the main clock signal of the BS CKU .........................................................................18
2.3.2 Software version error of the BIE..............................................................................................19
2.3.3 Major alarm of the standing wave ratio of the transmitter combiner .......................................19
2.3.4 Communication interruption of the OMU..................................................................................20
2.4 LEVEL- 3 ALARM...................................................................................................................................21
2.4.1 Check error of the uplink data from the receiving processor to the channel processor............21
2.4.2 Frame unit fault..........................................................................................................................24
2.4.3 Inconsistency of software versions.............................................................................................27
2.4.4 Out-of-lock of the transmitting RF self oscillator......................................................................28
2.4.5 Error of software versions..........................................................................................................29
2.4.6 Fault of the BS clock unit (CKU)...............................................................................................31
2.4.7 Fault of BIE switching chips......................................................................................................33
2.4.8 Faults of the BIE E1 interface....................................................................................................35
2.4.9 Alarm of fans of the BIE.............................................................................................................41
2.4.10 Alarm of temperature sensor ...................................................................................................47
2.4.11 Fault of buses...........................................................................................................................52
2.4.12 Alarm of power amplifiers (PAs)..............................................................................................53
2.4.13 Alarm of low-noise amplifiers of the receiver multi-coupler ..................................................55
-i-
ii
-iii-
iv
1 Equipment Maintenance
1.1Maintenance description
The objective of daily maintenance is to ensure an optimized working condition of the product, so
that the whole network runs properly. The classification of the daily maintenance of the ZXG10-BTS
(V1A), together with the maintenance requirements and recommendations will be described below.
1. Maintenance classification
Daily maintenance of ZXG10-BTS (V1A) can be classified into routine maintenance and emergent
maintenance.
The routine maintenance refers to periodical maintenance, which is divided into daily routine
maintenance and regular routine maintenance by their maintenance periods. Emergent maintenance
refers to the maintenance tasks to be immediately executed as required by sudden failures of the
ZXG10-BTS (V1A) equipment and network adjustment, e.g., equipment failure, user-reported fault,
and the emergent problems found out in routine maintenance. Emergent failures are characterized by
abrupt occurrence and serious influences on the QoS, so the maintenance personnel in the equipment
room are required to handle them decisively, cautiously and in-time. A detailed record must be made
afterward so as to eliminate potential faults.
2. Maintenance requirements and recommendations
The daily maintenance of ZXG10-BTS (V1A) equipment is a major task for the maintenance
personnel in the equipment room. Excellent daily maintenance is a key factor to ensure long-term
stable running of the equipment. Therefore, a set of equipment room maintenance regulations should
be formulated to regulate and guide the work of the maintenance personnel. The followings are some
basic requirements and recommendations for daily maintenance:
1) The maintenance personnel should implement the daily and regular routine check strictly and
keep a detailed record without any omission.
2) The maintenance personnel must keep the equipment room safe and tidy, with proper
temperature and humidity.
3) The maintenance personnel should follow the equipment operation specifications strictly,
-1-
avoid any operations on the equipment beyond the daily maintenance specifications, e.g.,
arbitrarily plugging/unplugging, resetting, starting and switching over the equipment, or
changing the data; and should wear an anti-static wrist strap when accessing the hardware
system, and store the damaged parts and the spare parts in anti-static bags, which should be
labeled of the category and stored properly.
4) The person in charge of the equipment room should keep the user accounts, passwords and
the user authorities for login to the local operation & maintenance console and to the network
management system, and distribute them to relevant persons according to their specific
authorities, so as to define the responsibility and authority clearly.
5) The maintenance personnel should handle detected problems and faults in time, report major
problems to relevant supervisors in time and contact the local office of ZTE to get an early
solution, which should be recorded in detail afterward.
6) Before on-duty, the maintenance personnel must undergo necessary training. Different
maintenance positions should be assumed by persons of the corresponding technical levels.
7) The frequently used tools and instruments should be checked, repaired and calibrated before
use to ensure their proper conditions. Generally, the following tools and instruments are
recommended to be prepared in the equipment room.
A. Tools and auxiliary materials: screwdriver (flat-head and Phillips), diagonal pliers, cable
stripper, unpacking pliers, electric iron, chip-extractor, programmer, eraser, tweezers,
spanner, electrical drill, tape, anti-static wrist strap, insulating tape and cable tie.
B. Instruments: Multimeter, thermometer, humidity meter, optical power meter and earth
resistance tester.
8) The power supply of the system should be kept stable and reliable, and the grounding of the
system should be checked regularly.
1.2Routine maintenance
1.2.1Daily routine maintenance
Daily routine maintenance includes the following items:
1. Equipment room environment
1) Temperature requirements:
-2-
-3-
of alarms. The recovered history alarms, current alarms and ordinary notifications can be
queried as needed. For the procedure of querying alarms, please see ZXG10-BSS (V1A)
Operation Manual; for the alarm causes and handling process, please see ZXG10-BSS
(V1A) Maintenance Manual.
B. Whether the Abis link is connected through or not, the LMT system of the BTS permits
the maintenance personnel to query the alarm status of boards in the site, including alarm
mode, alarm location, alarm content, fan running condition and rack temperature. Multiple
alarms may exist on the same board at a time, and the board color on the alarm viewing
interface represents the top alarm level existing on this board. Click the board, and all
alarm information on this board will be displayed. For the procedure of querying alarms,
please see ZXG10-BTS (V1A) Operation Manual; for alarm causes and handling process,
please see Chapter 2 of this Manual.
2) Running status of boards
Check whether the indication of the indicators for each board in the rack is normal. If any alarm
indicator is on, contact the technical personnel in time to locate and eliminate the fault.
The running information of the ZXG10-BTS (V1A) mainly comes from the indicators on the
panels of modules such as OMU and TRU. By the different flashing meanings of the indicators,
you can determine the running status of the equipment basically. For the meanings, causes and
handling of various indicator statuses, please see Section 3.1 of this Manual.
1.3Emergent maintenance
Emergent maintenance refers to the maintenance task which needs to be handled immediately in
response to the emergent fault of ZXG10-BTS (V1A) equipment. Emergent faults are characterized
by abrupt occurrence and serious influence on the QoS, so the maintenance personnel of the
equipment room are required to handle them decisively, cautiously and in-time. A detailed record
should be made afterward so as to eliminate potential faults.
Generally, the emergent handling process and measures for emergent faults can be summarized
based on the following two types of faults:
1. Emergent faults and disasters in the environment of the equipment room
1) Major faults: Fault of the power supply system; floods, fires; faults of the air conditioner
system which cause the temperature and humidity severely beyond the specifications.
-5-
2) Maintenance measures: When any alarm information is observed from the OMCR of the
BSS or the LMT system of the BTS, perform an immediate inspection on the environment of
the equipment room, locate the fault cause, and eliminate the fault quickly. Afterward, report to
the superior leaders and keep a detailed record to eliminate potential faults.
2. Emergent fault of the equipment
1) Major faults: including hardware faults, e.g., damage of boards and modules, not-in-position,
poor contact, and software faults, e.g., disorder of data and program, and improper upgrading.
2) Maintenance measures:
A. Through plugging/unplugging, some faults such as not-in-position and poor contact of
the hardware system can be solved; through the replacing or isolation method, the faults
such as hardware damage can be located; the data disorder can be queried and corrected
through operations in the OMCR of the BSS or the LMT system of the BTS.
B. Faults of the software and hardware are numerous and complicated. If the above simple
methods fail to solve the problem, please contact the technical personnel or the regional
office of ZTE Corporation, report to the relevant leaders, and keep a detailed record
afterward so as to eliminate potential faults.
-6-
3. Replacing method
The replacing method is to check the fault by replacing the circuit board in question with a normal
circuit board. When the plugging/unplugging method fails, the replacing method can be applied.
When plugging/unplugging and replacing the board, please see the precautions and operation
procedure for replacing the boards and parts as listed in Appendix A.
4. Isolation method
When a part of the system is faulty, the involved circuit board or racks can be isolated to check
whether the fault comes from mutual impact. For example, a typical application of the isolation
method is to self-loop the I/O interface of a circuit board so as to isolate and solve the problem of the
related system.
5. Self-test method
When the system or circuit board is powered on again judge if there is any fault by way of self-test.
Usually, when a circuit board is re-powered on for self-test, the indicators on its panel will flash
regularly, so that we can check whether the circuit board itself is faulty.
6. Pressing method
Such faults as poor contact can be removed by pressing the chips and cable connectors.
7. Comprehensive method
Any fault can be cleared by combining the above methods and taking advantage of ones
maintenance experience.
-7-
Operation item
Operator
Remarks
Operator
Remarks
handling result
Temperature
Equipment
Humidity
room
Working status of
environment
Equipment
running status
information
Running status of
boards
Operation item
Check the
BTS module
module
Clean the rack
Check the
connection of power
Hardware:
check
cables
Check the
connection of
grounding cables
Check the power
module
Transmission
Transmission
Antenna and
feeder
system
System
-8-
Operation item
Maintenance
period
Equipment room
environment
Temperature
Daily
Humidity
Daily
Working status of
Daily
Remarks
Daily
Equipment
Querying the
Daily
running status
alarm information
Running status of
Daily
boards
BTS module
check
Weekly
module
Clean the racks
Monthly
Check the
Monthly
connection of
Hardware:
check
power cables
Check the
Monthly
connection of
ground cables
Check the power
Monthly
module
Transmission
Transmission
quarterly
Antenna and
Antenna and
Half a year
feeder
feeder system
System
-9-
Person to handle:
Time
Fault source: informed by the user alarm system found in daily routine maintenance
others
Fault category:
Fault description:
Handling method:
Result:
-10-
2 Alarm Handling
2.1Alarm information and classification
The alarm management of the LTM system is an important part of BTS local operation and
maintenance. The LMT system, after it is put into operation, can perform centralized monitoring on
the overall running condition of the BTS for the purpose of real-time maintenance and recovery.
Whether the Abis link is connected through or not, the LMT system permits the maintenance
personnel to query the alarm status of boards in the site, and view the site alarms and rack alarm
information on the LMT alarm viewing interface.
Boards that may send alarms include:
1. Boards in the public shelf: operation and maintenance unit (OMU), BS interface equipment (BIE),
clock unit (CKU), external alarm collection module (EAM), signaling distribution unit (SDU) and
power supply (PSA).
2. Boards in the carrier shelf: frame unit (FU), carrier unit (CU), power supply (PSB), power
amplifier (PA), combiner HYCOM and multi-coupler MUL.
3. Others: fan, temperature.
In terms of real-time handling, the alarms include ordinary notifications and alarms. Ordinary
notifications only indicate unrepeatable or transient faults during the system running. Usually, if a
notification is not frequently repeated, it may be caused accidentally by the environment, which
needs no handling; if a notification is frequently repeated, or even the alarm occurs for a long time, it
must be checked and solved in time.
An alarm usually lasts for a certain time. According to the severity in the system, alarms are divided
into four levels. Following is the division of the four alarm levels, as shown in Table 2-1.
-11-
The scope of
The scope of
services seriously
equipment safety
running reliability
affected
seriously affected
seriously affected
BSC or a site
BSC or a site
BSC or a site
One or some
No influence
One or some
Alarm
level
channels
system
maintainability
seriously affected
carriers
Note: In the definition of the alarm levels, the affected scope only refers to one single index. That is,
if the affected scope of one single index, e.g., reliability, security reaches the specified scope, the
level of the alarm can be determined basically. If one alarm item has affected several indexes, the
alarm level should be raised.
The alarm information summary table of the LMT is shown in Table 2-2. For the detailed
information of the alarm, e.g., alarm cause, time limit of handling, handling process, please see
relevant contents of Section 2.2~2.5.
Table 2-2 Alarm information summary table
Alarm code
Alarm name
Alarm level
0xC00
0xD00
0x1301
combiner
0x1701
0xA08
-12-
(continued)
Alarm code
Alarm name
Alarm level
0xA0A
0xA18
0xA26
the BSC
0xB00
unit
0xA23
version
0xA24
version
0xB04
0xB05
0xB06
oscillator 5
0xB0F
0xC0C
0xF2A
version
0xC01
0xC09
0xC0A
0xD02
-13-
(contiued)
(contiued)
-14-
Alarm code
Alarm name
Alarm level
0xD03
0xD04
0xD05
0xD06
0xD07
0xD08
0xD09
0xD0A
0xD11
0xD12
0xD13
0xF01
Alarm of fan 1
0xF02
Alarm of fan 2
0xF03
Alarm of fan 3
0xF04
Alarm of fan 4
0xF05
Alarm of fan 5
0xF06
Alarm of fan 6
0xF07
Alarm of fan 7
0xF08
Alarm of fan 8
0xF09
Alarm of fan 9
0xF0D
0xF0E
0xF0F
0xF10
0xF11
0xF12
0x1002
0x1003
Alarm name
Alarm level
0x1100
0x1101
0x1102
0x1103
0x1105
0x1200
coupler
0x1201
coupler
0x1400
0x1500
0x1702
0x1703
0x1704
alarm unit
0x1708
0x1804
0x1106
PA
0x1107
the forward power and type, and the standing wave ratio
of the PA on the left
0xA22
0xB08
0xD14
0xF2B
combiner
(contiued)
-15-
Alarm name
Alarm level
0xA04
transceiver
0xA05
transceiver
0xA06
transceiver
0xA07
transceiver
0xA10
transceiver
0xA11
transceiver
0xA12
transceiver
0xA13
transceiver
0xA14
0xA1B
0xA1C
0xA1D
0xA1E
0xA1F
Alarm code
Alarm name
Alarm level
(continued)
-16-
0xA20
0xA21
0xB02
0xB03
0xB07
0xC08
CKU
0xC0D
0xD15
0xB10
(CU)
0xD0B
signal 1
0xD0C
signal 2
0xD0D
signal 3
0xD0E
signal 1
0xD0F
signal 2
0xD10
signal 3
0x1000
of the BS OMU
0x1001
0x1004
0x1104
0x1705
0x1706
(continued)
-17-
Alarm name
Alarm level
0x1709
0x170B
0x170D
0x1802
0x1803
0x1805
0x1806
0x1808
0x1809
0x180A
0x180B
0x180D
0x1108
2.2Level-1 alarm
None.
2.3Level- 2 alarm
2.3.1Alarm of the main clock signal of the BS CKU
Alarm code: 0xC00
Alarm content: Alarm of CKU main clock signal
Alarm level: 2
Alarm cause: hardware fault
Influence of the alarm: If the alarm occurs to an active CKU, this BS will fail to work normally; if
the alarm occurs to a standby CKU, the running reliability of the system will deteriorate.
Time limit of handling: Handle it at once.
-18-
-20-
6. If none of the above measures works, please contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
2.4Level- 3 alarm
2.4.1Check error of the uplink data from the receiving processor to the
channel processor
2.4.1.1Data check error of both the main-set and sub-set uplink data from the receiving
processor to the channel processor (DSP0)
Alarm code: 0xA08
Alarm content: Data check error of both the main-set and sub-set uplink data from the receiving
processor (RPP) to the channel processor (CHP) (DSP0)
Alarm level: 3
Alarm cause: Severe interference exists in the transmission channel from the RPP to the CHP (or the
lines are poorly contacted).
Influence of the alarm: The signal quality of the radio interface will deteriorate drastically, affecting
the voice quality and even the assignment will fail.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Check whether the CKU is properly inserted.
2. Check whether the backplane line gets loose.
3. Check whether the bit switch for the transmission matching resistance on the backplane is set
properly.
4. If none of the above operations works, reset the BTS to check if the fault still exists.
5. If none of the above measures works, please contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
-21-
2.4.1.2Data check error of both the main-set and sub-set uplink data from the receiving
processor to the channel processor (DSP1).
Alarm code: 0xA09
Alarm content: Data check error of both the main-set and sub-set uplink data from the receiving
processor (RPP) to the channel processor (CHP) (DSP1)
Alarm level: 3
Alarm cause: Severe interference exists in the transmission channel from the RPP to the CHP (or the
lines are poorly contacted).
Influence of the alarm: The signal quality of the radio interface will deteriorate drastically, the uplink
bit error will occur in timeslot 1 and timeslot 5. In serious situations, the conversation will be
interrupted and the assignment will fail.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Check whether the CKU is properly inserted.
2. Check whether the backplane line gets loose.
3. Check whether the bit switch for the transmission matching resistance on the backplane is set
properly.
4. If none of the above operations works, reset the BTS to check if the fault still exists.
5. If none of the above measures works, please contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.1.3Data check error of both the main-set and sub-set uplink data from the receiving
processor to the channel processor (DSP2).
Alarm code: 0xA0A
Alarm content: Data check error of both the main-set and sub-set uplink data from the receiving
processor (RPP) to the channel processor (CHP) (DSP2)
Alarm level: 3
-22-
Alarm cause: Severe interference exists in the transmission channel from the RPP to the CHP (or the
lines are poorly contacted).
Influence of the alarm: The signal quality of the radio interface will deteriorate drastically, the uplink
bit error will occur in timeslot 2 and timeslot 6. In serious situations, the conversation will be
interrupted and the assignment will fail.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Check whether the CKU is properly inserted.
2. Check whether the backplane line gets loose.
3. Check whether the bit switch for the transmission matching resistance on the backplane is set
properly.
4. If none of the above operations works, reset the BTS to check if the fault still exists.
5. If none of the above measures works, please contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.1.4Data check error of both the main-set and sub-set uplink data from the receiving
processor to the channel processor (DSP3).
Alarm code: 0xA0B
Alarm content: Data check error of both the main-set and sub-set uplink data from the receiving
processor (RPP) to the channel processor (CHP) (DSP3)
Alarm level: 3
Alarm cause: Severe interference exists in the transmission channel from the RPP to the CHP (or the
lines are poorly contacted).
Influence of the alarm: The signal quality of the radio interface will deteriorate drastically, the uplink
bit error will occur in timeslot 3 and timeslot 7. In serious situations, the conversation will be
interrupted and the assignment will fail.
Time limit of handling: Handle it as soon as possible.
-23-
Handling process:
1. Check whether the CKU is properly inserted.
2. Check whether the backplane line gets loose.
3. Check whether the bit switch for the transmission matching resistance on the backplane is set
properly.
4. If none of the above operations works, reset the BTS to check if the fault still exists.
5. If none of the above measures works, please contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
-24-
-25-
1. Reset the FUC first to see whether this alarm can be recovered.
2. If this alarm cannot be recovered by resetting, contact the regional office of ZTE Corporation as
soon as possible.
Alarm type: Equipment alarm
2.4.2.4LAPD link disconnection of the FUC and the BSC
Alarm code: 0xA26
Alarm content: LAPD link disconnection of FU and BSC.
Alarm level: 3
Alarm cause: No connection between layer-2 software of the FUC and the BSC during a certain
period of time.
Influence of the alarm: This FUC fails to work. If this FUC is BCCH-TRX, services of the cell will
be affected.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Check whether this alarm occurs to other FUCs of this BS. If this alarm occurs to all FUCs of this
BS, check whether any alarm occurs to the BIE and whether the E1 line is connected properly, and
check whether any alarm occurs to the SMB, LAPD and DSN board of the BSC. If any, locate this
fault and clear it.
2. Check whether the BSC data is correct, especially the T network connection data and the SMB
timeslot connection data.
3. If only the LAPD of one layer TRU is disconnected, check whether the backplane cable is
connected properly.
4. If only the LAPD of one TRU is disconnected, reset the FUC.
5. If the problem still exists, please contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
-26-
-27-
-28-
Alarm level: 3
Alarm cause: Clock signal instability or TRU phrase-locked loop failure
Influence of the alarm: This TRU may fail to make a call.
Time limit of handling: Handle it at once.
Handling process: Replace the TRU.
Alarm type: Equipment alarm
2.4.4.3Out-of-lock of the transmitting IF self oscillator 5
Alarm code: 0xB06
Alarm content: Out-of-lock of the transmitting IF self oscillator 5
Alarm level: 3
Alarm cause: Clock signal instability or TRU phrase-locked loop failure
Influence of the alarm: This TRU may fail to make a call.
Time limit of handling: Handle it at once.
Handling process: Replace the TRU.
Alarm type: Equipment alarm
-29-
-30-
-31-
-32-
Handling process:
1. Insert the board properly and reset it.
2. If the alarm appears again, it indicates that the D402 chip on the board may be out of order,
replace the board.
3. If the alarm still exists, the system clock may be abnormal, then reset the CKU.
4. In case that the alarm still exists, contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.7.3Fault of the BIE switching chip 3
Alarm code: 0xD03
Alarm content: Fault of the BIE switching chip 3
Alarm level: 3
Alarm cause: Faulty chip or abnormal clock signal
Influence of the alarm: The conversation is abnormal, or links between a part of TRUs and BSC
cannot be established, or the system fails to start normally.
Time limit of handling: Handle it at once.
Handling process:
1. Insert the board properly and reset it.
2. If the alarm appears again, it indicates that the D403 chip on the board may be out of order,
replace the board.
3. If the alarm still exists, the system clock may be abnormal, then reset the CKU.
4. In case that the alarm still exists, contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.7.4Fault of the BIE switching chip 4
Alarm code: 0xD04
-34-
2. If the alarm appears again, it indicates that the D101 chip on the board may be out of order,
replace the board.
3. In case that the alarm still exists, contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.8.2Read/write fault of the BIE E1 interface chip 2
Alarm code: 0xD06
Alarm content: Read/write fault of the BIE E1 interface chip 2
Alarm level: 3
Alarm cause: Chip or communication failure
Influence of the alarm: The conversation is abnormal, or links between a part of TRUs and BSC
cannot be established, or the system fails to start normally.
Time limit of handling: Handle it at once.
Handling process:
1. Insert the board properly and reset it.
2. If the alarm appears again, it indicates that the D201 chip on the board may be out of order,
replace the board.
3. In case that the alarm still exists, contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.8.3Read/write fault of the BIE E1 interface chip 3
Alarm code: 0xD07
Alarm content: Read/write fault of the BIE E1 interface chip 3
Alarm level: 3
Alarm cause: Chip or communications failure
Influence of the alarm: The conversation is abnormal, or links between a part of TRUs and BSC
-36-
-37-
-38-
-39-
2. If the alarm persists, indicating that the D101 chip on the board may be out of order, replace the
board.
3. If the alarm still exists, indicating that the system clock may be abnormal, reset the CKU.
4. If the alarm still exists, the physical link of the E1 A interface may be abnormal.
5. If the physical link is normal, and the alarm still exists, contact the regional office of ZTE
Corporation.
Alarm type: Equipment alarm
2.4.8.8Out of frame of the BIE E1 interface signal 2
Alarm code: 0xD12
Alarm content: Out of frame of the BIE E1 interface signal 2
Alarm level: 3
Alarm cause: Chip or clock failure, phase difference from the BSC clock, or poor E1 connection
Influence of the alarm: For occasional occurrence, it has little impact on conversations. But frequent
occurrence (once several minutes) will cause abnormal conversations or abnormal link establishment
between the extension rack TRU and the BSC.
Time limit of handling: If it occurs occasionally, and the CKU is in free run mode, this alarm may be
ignored; but for frequent occurrence, handle it as soon as possible.
Handling process:
1. Insert the board properly and reset it.
2. If the alarm appears again, indicating that the D201 chip on the board may be out of order, replace
the board.
3. If the alarm still exists, indicating that the system clock may be abnormal, reset the CKU.
4. If the alarm still exists, the physical link of the E1 B interface may be abnormal.
5. If the physical link is normal, while the alarm still exists, contact the regional office of ZTE
Corporation.
-40-
-41-
Alarm level: 3
Alarm cause: Failure of the top fan of the main rack
Influence of the alarm: The poor ventilation of the BTS cabinet will cause the temperature increase
and unstable BTS operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan in this position is switched on.
3. If the fan is switched on already, while the alarm still exists, contact the regional office of ZTE
Corporation.
Alarm type: Equipment alarm
2.4.9.2Fan 2 alarm
Alarm code: 0xF02
Alarm content: Alarm of fan 2
Alarm level: 3
Alarm cause: Failure of the middle fan of the main rack
Influence of the alarm: The poor ventilation of the BTS cabinet will cause the temperature increase
and unstable BTS operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan in this position is switched on.
-42-
3. If the fan is switched on already, while the alarm still exists, contact the regional office of ZTE
Corporation.
Alarm type: Equipment alarm
2.4.9.3Fan 3 alarm
Alarm code: 0xF03
Alarm content: Alarm of fan 3
Alarm level: 3
Alarm cause: Failure of the bottom fan of the main rack
Influence of the alarm: The poor ventilation of the BTS cabinet will cause the temperature increase
and unstable BTS operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan in this position is switched on.
3. If the fan is switched on already, while the alarm still exists, contact the regional office of ZTE
Corporation.
Alarm type: Equipment alarm
2.4.9.4Fan 4 alarm
Alarm code: 0xF04
Alarm content: Alarm of fan 4
Alarm level: 3
Alarm cause: Failure of the top fan of the extension rack 1
Influence of the alarm: The poor ventilation of the BTS cabinet will cause the temperature increase
-43-
-44-
2.4.9.6Fan 6 alarm
Alarm code: 0xF06
Alarm content: Alarm of fan 6
Alarm level: 3
Alarm cause: Failure of the bottom fan of the extension rack 1
Influence of the alarm: The poor ventilation of the BTS cabinet will cause the temperature increase
and unstable BTS operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan in this position is switched on.
3. If the fan is switched on already, while the alarm still exists, contact the regional office of ZTE
Corporation.
Alarm type: Equipment alarm
2.4.9.7Fan 7 alarm
Alarm code: 0xF07
Alarm content: Alarm of fan 7
Alarm level: 3
Alarm cause: Failure of the top fan of the extension rack 2
Influence of the alarm: The poor ventilation of the BTS cabinet will cause the temperature increase
and unstable BTS operation.
Time limit of handling: Handle it at once.
Handling process:
-45-
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan in this position is switched on.
3. If the fan is switched on already, while the alarm still exists, contact the regional office of ZTE
Corporation.
Alarm type: Equipment alarm
2.4.9.8Fan 8 alarm
Alarm code: 0xF08
Alarm content: Alarm of fan 8
Alarm level: 3
Alarm cause: Failure of the middle fan of the extension rack 2
Influence of the alarm: The poor ventilation of the BTS cabinet will cause the temperature increase
and unstable BTS operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan in this position is switched on.
3. If the fan is switched on already, while the alarm still exists, contact the regional office of ZTE
Corporation.
Alarm type: Equipment alarm
2.4.9.9Fan 9 alarm
Alarm code: 0xF09
Alarm content: Alarm of fan 9
-46-
Alarm level: 3
Alarm cause: Failure of the bottom fan of the extension rack 2
Influence of the alarm: The poor ventilation of the BTS cabinet will cause the temperature increase
and unstable BTS operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan in this position is switched on.
3. If the fan is switched on already, while the alarm still exists, contact the regional office of ZTE
Corporation.
Alarm type: Equipment alarm
-47-
2. Observe whether the fan is switched on already, if not, switch on the fan.
3. Observe whether the temperature is too high, and check the running of the air conditioner.
4. If the environment temperature cannot be lowered, shut down part of TRU to lower the
temperature inside the rack.
5. If both the fan and air conditioner are normal, while the alarm still exists, contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.10.2Alarm of temperature sensor 2
Alarm code: 0xF0E
Alarm content: Alarm of temperature sensor 2
Alarm level: 3
Alarm cause: The temperature at the lower part of the main rack is too high.
Influence of the alarm: The high temperature inside the BTS cabinet will cause the unstable BTS
operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan is switched on already; if not, switch on the fan.
3. Observe whether the temperature is too high, and check the running of the air conditioner.
4. If the environment temperature cannot be lowered, shut down part of TRU to lower the
temperature inside the rack.
5. If both the fan and air conditioner are normal, while the alarm still exists, contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
-48-
-49-
operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan is switched on already; if not, switch on the fan.
3. Observe whether the temperature is too high, and check the running of the air conditioner.
4. If the environment temperature cannot be lowered, shut down part of TRU to lower the
temperature inside the rack.
5. If both the fan and air conditioner are normal, while the alarm still exists, contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.10.5Alarm of temperature sensor 5
Alarm code: 0xF11
Alarm content: Alarm of temperature sensor 5
Alarm level: 3
Alarm cause: The temperature at the upper part of the extension rack 2 is too high.
Influence of the alarm: The high temperature inside the BTS cabinet will cause the unstable BTS
operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan is switched on already; if not, switch on the fan.
-50-
3. Observe whether the temperature is too high, and check the running of the air conditioner.
4. If the environment temperature cannot be lowered, shut down part of TRU to lower the
temperature inside the rack.
5. If both the fan and air conditioner are normal, while the alarm still exists, contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.10.6Alarm of temperature sensor 6
Alarm code: 0xF12
Alarm content: Alarm of temperature sensor 6
Alarm level: 3
Alarm cause: The temperature at the lower part of the extension rack 2 is too high.
Influence of the alarm: The high temperature inside the BTS cabinet will cause the unstable BTS
operation.
Time limit of handling: Handle it at once.
Handling process:
1. Observe the running status and alarm cables of EAM. If there is an alarm for EAM or the
backplane alarm cables are not connected properly, solve these problems first.
2. Observe whether the fan is switched on already; if not, switch on the fan.
3. Observe whether the temperature is too high, and check the running of the air conditioner.
4. If the environment temperature cannot be lowered, shut down part of TRU to lower the
temperature inside the rack.
5. If both the fan and air conditioner are normal, while the alarm still exists, contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
-51-
2.4.11Fault of buses
2.4.11.1Fault of the frame unit bus
Alarm code: 0x1002
Alarm content: FUBUS fault (communication interruption between OMU and all FUs)
Alarm level: 3
Alarm cause: High-speed HDLC bus failure, or OMU hardware error
Influence of the alarm: FUC and CHP versions and parameter configurations cannot be updated, and
alarms cannot be reported.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Reset or reinsert the OMU board.
2. Check the backplane and its connections.
3. If none of the measures works, contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.11.2Fault of the low-speed bus
Alarm code: 0x1003
Alarm content: OBBUS fault (communication interruption between OMU and BIE, CKU and EAM)
Alarm level: 3
Alarm cause: Low-speed (64K) HDLC bus failure, or OMU hardware error
Influence of the alarm: Parameter configurations of low-speed boards cannot be updated, and alarms
cannot be reported.
Time limit of handling: Handle it at once.
Handling process:
-52-
-54-
-55-
Alarm cause: Faulty low-noise amplifier of the multi-coupler, interference signals received by EAM,
or error connections of EAM alarm cables
Influence of the alarm: The faulty low-noise amplifier of the multi-coupler will affects
conversations, while the alarm caused by the interference signal received by EAM will have no
impact.
Time limit of handling: Handle it at once.
Handling process:
1. Check whether the EAM works normally.
2. Check whether the EAM alarm cable of the backplane is faulty. If the alarm occurs at the same
time as the alarm of low-noise amplifier 2 of the receiver multi-coupler, something may be wrong
with the backplane alarm cable.
3. If none of the measures works, contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.13.2Alarm of low-noise amplifier 2 of the receiver multi-coupler
Alarm code: 0x1201
Alarm content: Alarm of low-noise amplifier 2 of the receiver multi-coupler
Alarm level: 3
Alarm cause: Faulty low-noise amplifier of the multi-coupler, interference signals received by EAM,
or error connections of EAM alarm cables
Influence of the alarm: The faulty low-noise amplifier of the multi-coupler will affects
conversations, while the alarm caused by the interference signal received by EAM will have no
impact.
Time limit of handling: Handle it at once.
Handling process:
1. Check whether the EAM works normally.
2. Check whether anything is wrong with the EAM alarm cable of the backplane. If the alarm occurs
-56-
at the same time as the alarm of low-noise amplifier 1 of the receiver multi-coupler, something
may be wrong with the backplane alarm cable.
3. If none of the measures works, contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.14Power alarm
2.4.14.1Alarm of power supply of the carrier shelf
Alarm code: 0x1400
Alarm content: PSB alarm
Alarm level: 3
Alarm cause: Over-voltage, under-voltage, over-current and power-off of the PSB power supply;
interference signals received by EAM or error connections of EAM alarm cables
Influence of the alarm: The PSB power supply fault will affect the carrier shelf, especially the whole
carrier shelf may be out of work in serious cases. The alarm caused by the interference signal
received by EAM or error connection of the EAM alarm cable will have no influence on the system.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Check whether the EAM works normally.
2. Check whether anything is wrong with the EAM alarm cable of the backplane.
3. If alarm indicators on the panel light up at the same time, replace the PSB and contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
2.4.14.2Alarm of power supply of the public shelf
Alarm code: 0x1500
Alarm content: PSA alarm
-57-
Alarm level: 3
Alarm cause: Over-voltage, under-voltage, over-current and power-off of the PSA power supply;
interference signals received by EAM or error connections of EAM alarm cables
Influence of the alarm: The PSA power supply fault will affect the public shelf, especially the whole
public shelf may be out of work in serious cases. The alarm caused by the interference signal
received by EAM or error connection of the EAM alarm cable will have no influence on the system.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Check whether the EAM works normally.
2. If alarm indicators on the panel light up at the same time, replace the PSA and contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
-58-
-60-
-61-
Influence of the alarm: The alarm conditions of the board can not be viewed until the alarm is
recovered.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. If the alarm is recovered soon, improve the quality of the transmission link between BSC and
BTS, or no handling is required
2. If the alarm cannot be recovered for a long time, check step by step according to the alarm items
of Interruption of the EAM communication link.
3. If there is an alarm caused by timeout of the OMU unreported, handle it before handling the alarm
mentioned here.
4. If none of the measures works, contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
-62-
-63-
-65-
-66-
2.5Level 4 alarm
2.5.1Digital processor fault in the transceiver
2.5.1.1Initialization failure of digital processor 0 in the transceiver
Alarm code: 0xA04
Alarm content: DSP0 initialization fails.
Alarm level: 4
Alarm cause: DSP software or hardware error.
Influence of the alarm: If the TRU of the DSP0 is BCCH carrier, this cell will not work normally; if
it is not BCCH, two physical channels of the TRU will fail to work while others can.
Time limit of handling: If the alarm influences the BCCH carrier, handle it at once; if it just
influences the TCH carrier, handle it as soon as possible, otherwise the traffic capacity of this cell
will be affected.
Handling process:
1. Re-download the DSP software.
2. Reset this TRU frame and restart the DSP unit to see whether this alarm can be recovered. If the
alarm is recovered, it means that the DSP initialization failure is caused by the external strong
interference, and this TRU unit can work normally.
3. If this alarm cannot be recovered, contact the regional office of ZTE Corporation as soon as
possible.
Alarm type: Equipment alarm
2.5.1.2Initialization failure of digital processor 01 in the transceiver
Alarm code: 0xA05
Alarm content: DSP1 initialization fails.
Alarm level: 4
Alarm cause: DSP software or hardware error.
-67-
Influence of the alarm: Two timeslots of this TRU cannot work normally, that is, two physical
channels of this TRU can not be used, which will affect the traffic capacity of the cell.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Re-download the DSP software.
2. Reset this TRU frame and restart the DSP unit to see whether this alarm can be recovered. If the
alarm is recovered, it means that the DSP initialization failure is caused by the external strong
interference, and this TRU unit can work normally.
3. If this alarm cannot be recovered, contact the regional office of ZTE Corporation as soon as
possible.
Alarm type: Equipment alarm
2.5.1.3Initialization failure of digital processor 02 in the transceiver
Alarm code: 0xA05
Alarm content: DSP2 initialization fails.
Alarm level: 4
Alarm cause: DSP software or hardware error.
Influence of the alarm: Two timeslots of this TRU cannot work normally, that is, two physical
channels of this TRU can not be used, which will affect the traffic capacity of the cell.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Re-download the DSP software.
2. Reset this TRU frame and restart the DSP unit to see whether this alarm can be recovered. If the
alarm is recovered, it means that the DSP initialization failure is caused by the external strong
interference, and this TRU unit can work normally.
3. If this alarm cannot be recovered, contact the regional office of ZTE Corporation as soon as
possible.
-68-
-69-
abnormal work of two channels of a carrier unit. If it is a BCCH carrier, the whole cell will fail to
work normally.
Time limit of handling: Handle it at once.
Handling process:
1. Reset the carrier unit first to see whether this alarm can be recovered. If this alarm can be
recovered, it indicates that this alarm is caused by the abnormal internal status of the DSP, and the
carrier unit can work normally after resetting.
2. If this alarm cannot be recovered after resetting, contact the regional office of ZTE Corporation as
soon as possible.
Alarm type: Equipment alarm
2.5.1.6Software overflow of digital processing unit 1 in the transceiver
Alarm code: 0xA11
Alarm content: WatchDog of DSP1 overflows.
Alarm level: 4
Alarm cause: The DSP1 program of the channel processing unit runs out of service.
Influence of the alarm: The DSP1 program of the channel processing unit runs out of service, and the
control unit once again implements program loading and initialization to the DSP. If the alarm
cannot be recovered, it indicates that the DSP loading never succeeds. This fault may cause
abnormal work of two channels of a carrier unit.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Reset the carrier unit first to see whether this alarm can be recovered. If this alarm can be
recovered, it indicates this alarm is caused by the abnormal internal status of the DSP, and the carrier
unit can work normally after resetting.
2. If this alarm cannot be recovered by resetting, contact the regional office of ZTE Corporation as
soon as possible.
-70-
2.5.2Check error of the uplink data from the RPP to the CHP
2.5.2.1Check error of one channel of the uplink data from the RPP to the CHP (DSP0)
Alarm code: 0xA14
Alarm content: Check error of one channel of the uplink data from the RPP to the CHP (DSP0).
Alarm level: 4
Alarm cause: Slight interference exists on the transmission channel between the RPP and the CHP
(or the lines are poorly contacted).
Influence of the alarm: No obvious influence on the system network running.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. Check whether the CKU is properly inserted.
2. Check whether the backplane line gets loose.
3. Check whether the bit switch for the transmission matching impedance on the backplane is set
properly.
4. If none of the above operations works, reset the BTS to see whether the fault will re-occur.
-72-
-75-
Handling process: Re-configure the parameters on the background and make the parameter
synchronized with the BS.
Alarm type: Wrong handling.
2.5.4.2Channel 1 parameter configuration error
Alarm code: 0xA1B
Alarm content: The Ch1 parameter configuration error
Alarm level: 4
Alarm cause: The parameter configuration is improper or with conflicts.
Influence of the alarm: Usually the BSC background will check the data validity before
synchronizing the data, and only the valid data can be synchronized, so such alarm seldom occurs.
This alarm will affect the channel assignment and normal work.
Time limit of handling: Handle it at once.
Handling process: Re-configure the parameters on the background and make the parameters
synchronized with the BS.
Alarm type: Wrong handling.
2.5.4.3Channel 2 parameter configuration error
Alarm code: 0xA1C
Alarm content: The Ch2 parameter configuration error
Alarm level: 4
Alarm cause: The parameter configuration is improper or with conflicts.
Influence of the alarm: Usually the BSC background will check the data validity before
synchronizing the data, and only the valid data can be synchronized, so such alarm seldom occurs.
This alarm will affect the channel assignment and normal work.
Time limit of handling: Handle it at once.
Handling process: Re-configure the parameters on the background and make the parameters
-76-
-77-
-78-
-79-
-80-
Alarm cause: This alarm occurs only in the condition of the whole network synchronization, it may
be caused by the unstable CKU clock source or the CKU phase-locked loop fault.
Influence of the alarm: Basically this BS can work normally, while the slide code alarm and out-offrame alarm may occur.
Time limit of handling: Put it off.
Handling process:
1. Maybe the current 8K clock jitters quite sharply, observe for a certain period of time. If the out-oflock alarm occurs repeatedly for one day, replace the board.
2. If all the boards give alarms, it indicates a poor line, switch over to the free-oscillation mode.
3. If none of the above measures works, contact the regional office of ZTE Corporation.
Alarm type: Equipment alarm
-82-
-83-
-84-
connection
Influence of the alarm: For occasional occurrence, it has little influence on the conversation.
Frequent occurrences (once several minutes) will cause abnormal communication or abnormal link
set-up between the cascaded rack TRU and the BSC.
Time limit of handling: If it occurs occasionally, and the CKU is in the free run mode, this alarm
may not be handled; while for frequent occurrences, handle it as soon as possible.
Handling process:
1. Insert the board properly and reset it.
2. If the alarm still exists, it indicates that the D301 chip on the board may be faulty, replace the
board.
3. If the alarm still exists, it indicates the system clock may be abnormal, reset the CKU.
4. If the alarm still exists, the physical link of the E1 C interface may be abnormal.
5. If the physical link of the E1 C interface is normal, while the alarm still exists, contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
2.5.8.4Backward slide code indication of the BIE E1 interface signal 1
Alarm code: 0xD0E
Alarm content: Backward slide code indication of the BIE E1 interface signal 1
Alarm level: 4
Alarm cause: Chips faulty or clocks abnormal, phase difference from the BSC clock or poor E1
connection
Influence of the alarm: For occasional occurrence, it has little influence on the communication.
Frequent occurrences (once several minutes) will cause abnormal communication or abnormal link
set-up between the host rack TRU and the BSC.
Time limit of handling: If it occurs occasionally, and the CKU is in the free run mode, this alarm
may not be handled; while for frequent occurrences, handle it as soon as possible.
-85-
Handling process:
1. Insert the board properly and reset it.
2. If the alarm still exists, it indicates that the D101 chip on the board may be faulty, replace the
board.
3. If the alarm still exists, it indicates the system clock may be abnormal, reset the CKU.
4. If the alarm still exists, the physical link of the E1 A interface may be abnormal.
5. If the physical link of the E1 A interface is normal, and the alarm still exists, contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
2.5.8.5Backward slide code indication of the BIE E1 interface signal 2
Alarm code: 0xD0F
Alarm content: Backward slide code indication of the BIE E1 interface signal 2
Alarm level: 4
Alarm cause: Chips faulty or clocks abnormal, phase difference from the BSC clock or poor E1
connection
Influence of the alarm: For occasional occurrence, it has little influence on the communication.
Frequent occurrences (once several minutes) will cause abnormal communication or abnormal link
set-up between the extension rack TRU and the BSC.
Time limit of handling: If it occurs occasionally, and the CKU is in the free run mode, this alarm
may not be handled; while for frequent occurrences, handle it as soon as possible.
Handling process:
1. Insert the board properly and reset it.
2. If the alarm still exists, it indicates that the D201 chip on the board may be faulty, replace the
board.
3. If the alarm still exists, it indicates the system clock may be abnormal, reset the CKU.
-86-
4. If the alarm still exists, the physical link of the E1 B interface may be abnormal.
5. If the physical link of the E1 B interface is normal, while the alarm still exists, contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
2.5.8.6Backward slide code indication of the BIE E1 interface signal 3
Alarm code: 0xD10
Alarm content: Backward slide code indication of the BIE E1 interface signal 3
Alarm level: 4
Alarm cause: Chips faulty or clocks abnormal, phase difference from the BSC clock or poor E1
connection
Influence of the alarm: For occasional occurrence, it has little influence on the communication.
Frequent occurrences (once several minutes) will cause abnormal communication or abnormal link
set-up between the cascaded rack TRU and the BSC.
Time limit of handling: If it occurs occasionally, and the CKU is in the free run mode, this alarm
may not be handled; while for frequent occurrences, handle it as soon as possible.
Handling process:
1. Insert the board properly and reset it.
2. If the alarm still exists, it indicates that the D301 chip on the board may be faulty, replace the
board.
3. If the alarm still exists, it indicates the system clock may be abnormal, reset the CKU.
4. If the alarm still exists, the physical link of the E1 C interface may be abnormal.
5. If the physical link of the E1 C interface is normal, while the alarm still exists, contact the regional
office of ZTE Corporation.
Alarm type: Equipment alarm
-87-
-88-
-89-
Handling process:
1. Check whether the fans work normally and whether the temperature of the environment is too
high.
2. If the fans work normally and the environment temperature is normal, while the PA overtemperature alarm still exists, maybe the detecting circuit is faulty, replace the PA.
Alarm type: Equipment alarm
-90-
-91-
-92-
2. If both the OMU and EAM work normally, check whether the alarm line of the backplane is
properly connected. For anything abnormal, correct it.
3. If the fault still exists, replace the board and contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
-94-
set to a relatively short duration (the alarm will be recovered very soon); FU communication link is
disconnected.
Influence of the alarm: The alarm condition of the board can not be viewed until the alarm is
recovered.
Time limit of handling: handle it as soon as possible.
Handling process:
1. If the alarm is recovered very quickly, improve the quality of the transmission link between BSC
and BTS, or no handling is required.
2. If the alarm is not recovered for a long time, check step by step according to the FU
communication link disconnected alarm item.
3. Check whether there is the alarm of timeout of OMU unreported, if yes, handle it first before
handling this alarm.
4. If none of the measures works, contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
2.5.12.4 The carrier unit is unreported till timeout
Alarm code: 0x1806
Alarm content: the CU board is not reported till timeout
Alarm level: 4
Alarm cause: The direct cause is that the O&M messages of the board can not be received on BSC
side in a certain period of time. The possible causes: the link is blocked and the timer on the BSC
side is set to a relatively short duration (the alarm will be recovered very soon); CU communication
link is disconnected.
Influence of the alarm: The alarm condition of the board can not be viewed until the alarm is
recovered.
Time limit of handling: handle it as soon as possible.
Handling process:
-96-
1. If the alarm is recovered very quickly, improve the quality of the transmission link between BSC
and BTS, or no handling is required.
2. If the alarm is not recovered for a long time, check step by step according to the CU
communication link disconnected alarm item.
3. Check whether there is the alarm of timeout of OMU unreported, if yes, handle it first before
handling this alarm.
4. If none of the above measures works, contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
2.5.12.5 The power board of the public shelf is unreported till timeout
Alarm code: 0x1808
Alarm content: The PSA board is not reported till timeout
Alarm level: 4
Alarm cause: The direct cause is that the O&M messages of the board can not be received on the
BSC side in a certain period of time. The possible causes: the link is blocked and the timer on the
BSC side is set to a relatively short duration (the alarm will be recovered very soon); PSA
communication link is disconnected.
Influence of the alarm: The alarm condition of the board can not be viewed until the alarm is
recovered.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. If the alarm is recovered very quickly, improve the quality of the transmission link between BSC
and BTS, or no handling is required.
2. If the alarm is not recovered for a long time, check step by step according to the PSA
communication link disconnected alarm item.
3. Check whether there is the alarm of timeout of OMU unreported, if yes, handle it first before
handling this alarm.
-97-
4. If none of the above measures works, contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
2.5.12.6 The power board of the carrier shelf power board is unreported till timeout
Alarm code: 0x1809
Alarm content: The PSB board is not reported till timeout
Alarm level: 4
Alarm cause: The direct cause is that the O&M messages of the board can not be received on BSC
side in a certain period of time. The possible causes: the link is blocked and the timer on the BSC
side is set to a relatively short duration (the alarm will be recovered very soon); PSB communication
link is disconnected.
Influence of the alarm: The alarm condition of the board can not be viewed until the alarm is
recovered.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. If the alarm is recovered very quickly, improve the quality of the transmission link between BSC
and BTS, or no handling is required.
2. If the alarm is not recovered for a long time, check step by step according to the PSB
communication link disconnected alarm item.
3. Check whether there is the alarm of timeout of OMU unreported, if yes, handle it first before
handling this alarm.
4. If none of the above measures works, contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
2.5.12.7 The power amplifier is unreported till timeout
Alarm code: 0x180A
Alarm content: Timeout of the PA board is not reported
-98-
Alarm level: 4
Alarm cause: The direct cause is that the O&M messages of the board can not be received on BSC
side in a certain period of time. The possible causes: the link is blocked and the timer on the BSC
side is set to a relatively short duration (the alarm will be recovered very soon); PA communication
link is disconnected.
Influence of the alarm: The alarm condition of the board can not be viewed until the alarm is
recovered.
Time limit of handling: Handle it as soon as possible.
Handling process:
1. If the alarm is recovered very quickly, improve the quality of the transmission link between BSC
and BTS, or no handling is required.
2. If the alarm is not recovered for a long time, check step by step according to the PA
communication link disconnected alarm item.
3.Check whether there is the alarm that OMU is unreported till timeout, if yes, handle it first before
handling this alarm. .
4. If none of the above measures works, contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
2.5.12.8 The multi-coupler is unreported till timeout
Alarm code: 0x180B
Alarm content: The MUL board is not reported till timeout
Alarm level: 4
Alarm cause: The direct cause is that the O&M messages of the board can not be received on BSC
side in a certain period of time. The possible causes: the link is blocked and the timer on the BSC
side is set to a relatively short duration (the alarm will be recovered very soon); MUL
communication link is disconnected.
Influence of the alarm: The alarm condition of the board can not be viewed until the alarm is
recovered.
-99-
-100-
3. Check whether there is the alarm of timeout of OMU unreported, if yes, handle it first before
handling this alarm.
4. If none of the above measures works, contact the regional office of ZTE Corporation.
Alarm type: Communication alarm
-101-
Power supply
Alarm
indicator (green)
indicator (red)
Normally off
Normally off
Normally off
Normally off
Normally on
BOOT starting
Normally on
Normally off
4 Hz flashing
Normally off
Active status
Normally on
Normally on
Standby status
Normally on
Normally off
Normally on
Normally on
Normally on
Normally on
Normally on
Normally on
1 Hz flashing
Normally on
1 Hz flashing
1 Hz flashing
Normally on
Normally on
4 Hz flashing
4 Hz flashing
Normally on
Normally on
1 Hz flashing
4 Hz flashing
Normally on
Indicated status
Fault of the 4M or 8K
clock
LAPD link disconnected
System initialization
status
File downloading
-102-
indicator
(green)
Active/stand
by (yellow)
There are five indicators on the TRU board, i.e., power supply indicator, alarm indicator, running
indicator, status indicator ST1 and status indicator ST2 from top downwards. Meanings of
combinations of the panel indicators are shown in Table 3-2.
Table 3-2 Names and meanings of the TRU indicators
Indicated status
Power supply
Alarm
Running
Status
Status
indicator (green)
indicator
indicator
indicator
indicator
(red)
(green)
ST1
ST2
Normally off
Normally on
BOOT starting
Normally on
Normally
4Hz flash
Normally on
1Hz flashing
off
Process initially started
Normally on
Normally
on
Fault of 4M or 8K clock
Normally on
Normally
on
Normally on
1Hz flash
1Hz flashing
Normally on
4Hz flash
1Hz flash
Normally on
4Hz
4Hz flashing
4Hz flashing
Normally
flashing
File downloading
Normally on
1Hz
flashing
on
Note:
1) X means the indicator can be in any status .
2) The priority sequence of the indicators in working status is shown as follows: the priority
gradually decreases from top downwards, i.e., fault of 4M or 8K clock ----LAPD link
disconnected ----HDLC link disconnected ----file downloading ----system initialization status
3) ST1: Status indicator 1.If it is normally on, it means that this TRU is the carrier shelf where
the BCCH channel is located. If it is normally off, it means that this TRU is the carrier shelf
where the non-BCCH channel is located.
4) ST2: Status indicator 2.It is reserved in design, and not used in actual running.
-103-
3. BIE
There are four indicators on the BIE panel, i.e., power supply indicator, alarm indicator, running
indicator, and active/standby indicator from top downwards. Meanings of combinations of the panel
indicators are shown in Table 3-3.
Table 3-3 Names and meanings of the BIE indicators
Indicated status
Alarm
indicator
(red)
Running
indicator
(green)
Active/standby
(yellow)
Normally off
Normally off
Normally off
Normally off
Normally on
Normally on
Normally on
1Hz flashing
1Hz flash
Working normally
Normally on
Normally off
1Hz flash
Active
Normally on
Normally on
Alarm
indicator
(red)
Running
indicator (green)
Active/standby
(yellow)
Normally off
Normally off
Normally off
Normally off
Normally on
Normally on
8K E1 alarm
Normally on
Normally on
1Hz flashing
Normally on
4Hz flashing
1Hz flash
Working normally
Normally on
Normally off
1Hz flashing
Active
Normally on
Normally on
Parameter configuration
Normally on
4Hz flashing
4Hz flashing
-104-
5. CKU
There are five indicators on the CKU board, i.e., power supply indicator, alarm indicator, running
indicator, active/standby indicator and phase lock indicator from top downwards. Meanings of
combinations of the panel indicators are shown in Table 3-5.
Table 3-5 Names and meanings of the CKU indicators
Indicated
status
Power supply
indicator (green)
Alarm indicator
Running indicator
(green)
Active/stan
dby (yellow)
Phase lock
indicator
(green)
(red)
The board is
not powered
on
Normally off
Normally off
Normally off
Normally off
Normally off
Initialization
Normally on
4Hz flash
The program
runs out of
service
Normally on
Normally on
Working
normally
Normally on
Normally off
1Hz flash
Active
Normally on
Normally on
Phase lock
status
Normally on
4Hz flashing
Locked
status
Normally on
Normally on
The whole
network
asynchronou
s
Normally on
Normally off
The clock
frame
number
abnormal.
Normally on
Normally on
HDLC link
not
established
Normally on
1 Hz flashing
The 8K
clock
abnormal
Normally on
1 Hz
flashing
(green)
Running indicator
(green)
Normally off
Normally off
Normally off
Initialization
Normally on
4Hz flashing
Working normally
Normally on
Normally off
1Hz flashing
Normally on
1 Hz flashing
1 Hz flashing
Normally on
Normally on
Normally on
-106-
-107-
-108-
-109-
5. Precautions: None.
3.3.3BOOT starting
1. Meaning: OMU BOOT starting
2. Relative information: None.
3. Cause: When the board is started, BOOT invokes the programs from the FLASH into the memory.
4. Handling method: No handling is required.
5. Precautions: None.
-110-
-111-
-112-
-113-
4) If none of the above measures works, please contact the regional office of ZTE Corporation.
5. Precautions: None.
-114-
-115-
4. Handling method: The system can keep on running, but no data configuration can be made. If
EBIE link is disconnected for a long time, the user may try the following methods for
troubleshooting.
1) Check whether the EBIE board is inserted properly.
2) Reset the EBIE board to see whether the alarm is recovered.
3) Check whether the clock board works normally.
4) If none of the above measures works, please contact the regional office of ZTE Corporation.
5. Precautions: None.
-116-
3.6.2CKU initialization
1. Meaning: CKU initialization.
2. Relative information: None.
3. Cause: The board hardware and software are initialized.
4. Handling method: No handling is required.
5. Precautions: None.
-117-
-118-
-119-
1) The disconnection of LAPD of OMU is a normal case. Handle the problem of the LAPD link
of OMU first in this case.
2) If links are established for all other MOs inside the rack, then replace the CKU board.
5. Precautions: None.
3.7.2EAM initialization
1. Meaning: EAM initialization.
2. Relative information: None.
3. Cause: The board hardware and software are initialized.
4. Handling method: No handling is required.
5. Precautions: None.
-120-
-121-
5. Precautions: None.
-122-
8. Make sure to insert the module in position, and tighten the panel screws of the module.
9. For replacing the power board and MP, plugging/unplugging with power-on is strictly prohibited.
-124-
faulty. Store the faulty boards properly in the cartons according to different types. The
cartons should also be labeled on the exterior for later identification and handling.
5) Insert the spare board into the specified slot of the plug-in frame in accordance with its
name. Press the spanner on the board with the thumb and push in the board with proper force
until the spanner is locked, indicating that the board is placed in position. Then tighten the
screws on the panel.
6) Switch on the PSB power supply of this layer.
3. Confirm after the replacement
When the board is just plugged, it will take some for self-test. If the self-test is successful, the
indicator will display normally and the service is resumed, indicating successful replacement. Refer
to Chapter 3 in this manual for the judgment method of the indicator status display. If the self-test
fails, i.e., the self-test is repeated endlessly or the final display is abnormal, and the service of the
relative unit is not resumed, it indicates unsuccessful replacement. Then please check and determine
once again whether the spare part is damaged, or the cause of the fault does not lie in this board, then
locate the fault through observing the alarms in LMT.
-126-
Appendix B Abbreviations
Abbr.
English name
Abis
ARFCN
BCCH
BIE
BER
BSC
BSIC
BTS
CCCH
CELL
Cellular
CHP
Channel Processor
CKU
Clock Unit
CU
Carrier Unit
DAAU
DTX
Discontinuous Transmission
E1
EAM
EBIE
FU
Frame Unit
GPRS
HDLC
HW
HighWay
HYM (HYCOM)
Hybrid Combiner
LAPD
127
(continued)
Abbr.
English name
LAPDm
LM
Local Manager
LMT
MMI
Man-Machine Interface
MO
Managed Object
MS
Mobile Station
MSC
MUL
Multi Coupler
OMC
OMU
PA
Power Amplifier
PEU
PSA
Power Supply A
PSB
Power Supply B
PUB
RACH
SDU
SITE
-128-
TCH/F
TCH/H
TEI
TRU
Transceiver Unit
TRX
Transceivers
Um