You are on page 1of 32

GRUNDFOS A WIDE RANGE OF QUALITY PUMPS

50 Hz
GRUNDFOS

A global business

With over 10,000 employees and annual production of


some 8 million pump units a year, Grundfos is one of the
world’s leading pump manufacturers. More than 50 com-
panies right across all the continents of the globe help to
bring pumps to every corner of the world, from supplying
drinking water to Antarctic expeditions, irrigation of Dutch
tulips, groundwater monitoring beneath waste heaps in
Germany, to air-conditioning in Egyptian hotels.

Efficient, sustainable products Research and development make use of the latest techno-
Grundfos is constantly striving to make its products more logy within the pump industry, collaborating with universi-
userfriendly and reliable – and also energy-saving and effi- ties and higher education institutions in search of new and
cient, so that both users and the environment benefit from better solutions for the design and function of the products.
their improvements.
Grundfos pumps are equipped with ultramodern electron- Corporate values
ics, allowing them to regulate their output according to cur- The Grundfos Group is based on values such as sustaina-
rent needs. This not only ensures convenience for the bility, openness, trustworthiness, responsibility, and also
user, but also saves a great deal of energy. on partnership with clients, suppliers and the whole of soci-
ety around us, with a focus on humanity that concerns our
Research and development own employees as well as the many millions who benefit
In order to maintain its leading position, Grundfos con- from water that is procured, utilised and removed as
stantly places a great deal of emphasis on customerori- wastewater with the help of Grundfos pumps.
ented research and development; customers are
consulted when new products are developed or when
established products are improved.

3
Pumps for all purposes

No matter for which purpose an efficient and


energysaving pump solution is required,
Grundfos offers a high-quality solution.

Heating and hot Cooling and air- Industrial Pressure boosting Groundwater
water service conditioning applications and liquid transfer supply
systems systems

Circulator pumps for Circulator pumps for A wide range of Vertical and hori- Submersible and dry
circulation of hot circulation of cold pumps for the trans- zontal, centrifugal installed pumps for
water in central and water and other fer of water, cooling pumps and pressure groundwater supply,
district heating sys- liquids in cooling lubricants and other boosting systems for irrigation and
tems and circulation and air-conditioning liquids in industrial liquid transfer and groundwater lower-
in domestic hot systems. and process sys- boosting of hot and ing.
water service sys- tems. cold water.
tems.

4
GRUNDFOS

Domestic water Wastewater Environmental Dosing Renewable-energy


supply applications systems

Submersible pumps, Drainage, effluent Purpose-built Dosing pumps for Renewable-energy-


jet pumps, multistage and sewage pumps, submersible pumps wastewater treatment based water supply
centrifugal pumps for a wide range of for remedial pumping systems, systems suitable for
and compact systems applications in build- of contaminated swimming-pools and remote locations not
for water supply in ing services, the groundwater and for industry. connected to the
homes, gardens and industry as well sampling for water electricity supply grid.
hobby applications. as transfer of raw quality analyses.
sewage in municipal
sewage systems and
treatment plants.

5
Product and application overview

Heating and hot water service Industrial applications


systems AMD, AMG, AFG . . . . . . . . . . . . . . . . . . . 26
Delta Control 2000 . . . . . . . . . . . . . . . . . . 11 BMP . . . . . . . . . . . . . . . . . . . . . . . . . 19
DME, DMS . . . . . . . . . . . . . . . . . . . . . . 13 BM, BMB . . . . . . . . . . . . . . . . . . . . . . . 19
DMM . . . . . . . . . . . . . . . . . . . . . . . . . 13 BME, BMET . . . . . . . . . . . . . . . . . . . . . 20
DMX/DMH . . . . . . . . . . . . . . . . . . . . . . 14 BMEX. . . . . . . . . . . . . . . . . . . . . . . . . 20
GRUNDFOS ALPHA Pro, GRUNDFOS ALPHA+, CH, CHN . . . . . . . . . . . . . . . . . . . . . . . 23
UPS, UP Series 100 . . . . . . . . . . . . . . . . . .8 CHI, CHIU . . . . . . . . . . . . . . . . . . . . . . 14
GRUNDFOS COMFORT UP-N, UP(S)-B Series 100 .8 CHIE . . . . . . . . . . . . . . . . . . . . . . . . . 15
GRUNDFOS MAGNA, Series 2000 . . . . . . . . . .9 CHV . . . . . . . . . . . . . . . . . . . . . . . . . 24
TPE Series 1000 . . . . . . . . . . . . . . . . . . . 10 Contra . . . . . . . . . . . . . . . . . . . . . . . . 17
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . 11 Control 2000 . . . . . . . . . . . . . . . . . . . . . 19
NBE . . . . . . . . . . . . . . . . . . . . . . . . . 12 CR, CRI, CRN . . . . . . . . . . . . . . . . . . . . 15
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . 11 CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . . 17
NKE . . . . . . . . . . . . . . . . . . . . . . . . . 12 CRT. . . . . . . . . . . . . . . . . . . . . . . . . . 16
TP . . . . . . . . . . . . . . . . . . . . . . . . . . .9 CV, CPV, CPH . . . . . . . . . . . . . . . . . . . . 16
TPE Series 2000 . . . . . . . . . . . . . . . . . . . .9 DME, DMS . . . . . . . . . . . . . . . . . . . . . . 13
UPS Series 200 . . . . . . . . . . . . . . . . . . . .8 DMM . . . . . . . . . . . . . . . . . . . . . . . . . 13
DMX/DMH . . . . . . . . . . . . . . . . . . . . . . 14
DP, EF, SE1 and SEV . . . . . . . . . . . . . . . . 29
Cooling and air-conditioning
DW . . . . . . . . . . . . . . . . . . . . . . . . . . 26
systems
Euro-HYGIA® . . . . . . . . . . . . . . . . . . . . . 17
CHI, CHIU . . . . . . . . . . . . . . . . . . . . . . 14
Hydro 2000, Hydro 1000, Hydro Solo, Hydro Multi-E 18
CHIE . . . . . . . . . . . . . . . . . . . . . . . . . 15
TPE Series 1000 . . . . . . . . . . . . . . . . . . . 10
CH, CHN . . . . . . . . . . . . . . . . . . . . . . . 23
MAXA and MAXANA . . . . . . . . . . . . . . . . . 18
CHV . . . . . . . . . . . . . . . . . . . . . . . . . 24
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . 11
CR, CRI, CRN . . . . . . . . . . . . . . . . . . . . 15
NBE. . . . . . . . . . . . . . . . . . . . . . . . . . 12
CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . . 17
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . 11
CV, CPV, CPH . . . . . . . . . . . . . . . . . . . . 16
NKE. . . . . . . . . . . . . . . . . . . . . . . . . . 12
Delta Control 2000 . . . . . . . . . . . . . . . . . . 11
S pumps . . . . . . . . . . . . . . . . . . . . . . . 28
DME, DMS . . . . . . . . . . . . . . . . . . . . . . 13
SRP pumps. . . . . . . . . . . . . . . . . . . . . . 28
DMM . . . . . . . . . . . . . . . . . . . . . . . . . 13
SEN. . . . . . . . . . . . . . . . . . . . . . . . . . 29
DMX/DMH . . . . . . . . . . . . . . . . . . . . . . 14
SE . . . . . . . . . . . . . . . . . . . . . . . . . . 29
GRUNDFOS ALPHA Pro, GRUNDFOS ALPHA+,
UPS, UP Series 100 . . . . . . . . . . . . . . . . . .8 SIPLA. . . . . . . . . . . . . . . . . . . . . . . . . 18
GRUNDFOS COMFORT UP-N, UP(S)-B Series 100 .8 SPK, CHK, MTH, CRK, MTR, MTA. . . . . . . . . . 12
TPE Series 1000 . . . . . . . . . . . . . . . . . . . 10 SPKE, CRKE . . . . . . . . . . . . . . . . . . . . . 13
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . 11 Pressure tanks . . . . . . . . . . . . . . . . . . . . 25
NBE . . . . . . . . . . . . . . . . . . . . . . . . . 12
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . 11
NKE . . . . . . . . . . . . . . . . . . . . . . . . . 12
TP . . . . . . . . . . . . . . . . . . . . . . . . . . .9
TPE Series 2000 . . . . . . . . . . . . . . . . . . . .9
UPS Series 200 . . . . . . . . . . . . . . . . . . . .8

6
GRUNDFOS

Product and application overview

Pressure boosting and liquid RMQ . . . . . . . . . . . . . . . . . . . . . . . . . 24


transfer SP A, SP, SP-G . . . . . . . . . . . . . . . . . . . 21
BM, BMB . . . . . . . . . . . . . . . . . . . . . . 19 SQ, SQE. . . . . . . . . . . . . . . . . . . . . . . 20
BME, BMET . . . . . . . . . . . . . . . . . . . . . 20 Pressure tanks. . . . . . . . . . . . . . . . . . . . 25
BMEX . . . . . . . . . . . . . . . . . . . . . . . . 20
CH, CHN . . . . . . . . . . . . . . . . . . . . . . 23
Wastewater
CHI, CHIU . . . . . . . . . . . . . . . . . . . . . . 14
AMD, AMG, AFG . . . . . . . . . . . . . . . . . . 26
CHIE. . . . . . . . . . . . . . . . . . . . . . . . . 15
CHI, CHIU . . . . . . . . . . . . . . . . . . . . . . 14
CHV booster. . . . . . . . . . . . . . . . . . . . . 25
CHIE . . . . . . . . . . . . . . . . . . . . . . . . . 15
CHV . . . . . . . . . . . . . . . . . . . . . . . . . 24
DME, DMS. . . . . . . . . . . . . . . . . . . . . . 13
Control 2000. . . . . . . . . . . . . . . . . . . . . 19
DMM . . . . . . . . . . . . . . . . . . . . . . . . . 13
CR, CRI, CRN . . . . . . . . . . . . . . . . . . . . 15
DMX/DMH . . . . . . . . . . . . . . . . . . . . . . 14
CR, CRN high pressure . . . . . . . . . . . . . . . 15
DP, EF, SE1 and SEV . . . . . . . . . . . . . . . . 29
CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . 17
DW. . . . . . . . . . . . . . . . . . . . . . . . . . 26
CRT . . . . . . . . . . . . . . . . . . . . . . . . . 16
Unilift CC, KP, AP12, AP35/50, AP35B/50B. . . . . 25
CV, CPV, CPH. . . . . . . . . . . . . . . . . . . . 16
Lifting stations . . . . . . . . . . . . . . . . . . . . 27
GP . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Sololift+ . . . . . . . . . . . . . . . . . . . . . . . 27
Hydro 2000, Hydro 1000, Hydro Solo, Hydro Multi-E 18
Liftaway B and C . . . . . . . . . . . . . . . . . . 27
TPE Series 1000 . . . . . . . . . . . . . . . . . . 10
Conlift . . . . . . . . . . . . . . . . . . . . . . . . 28
MQ . . . . . . . . . . . . . . . . . . . . . . . . . 24
S pumps . . . . . . . . . . . . . . . . . . . . . . . 28
NB, NBG . . . . . . . . . . . . . . . . . . . . . . .11
SRP pumps . . . . . . . . . . . . . . . . . . . . . 28
NBE . . . . . . . . . . . . . . . . . . . . . . . . . 12
SEG . . . . . . . . . . . . . . . . . . . . . . . . . 26
NK, NKG . . . . . . . . . . . . . . . . . . . . . . .11
SEN . . . . . . . . . . . . . . . . . . . . . . . . . 29
NKE . . . . . . . . . . . . . . . . . . . . . . . . . 12
SE . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Groundwater supply Environmental applications


DME, DMS . . . . . . . . . . . . . . . . . . . . . 13
CR, CRI, CRN . . . . . . . . . . . . . . . . . . . . 15
DMM. . . . . . . . . . . . . . . . . . . . . . . . . 13
CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . 17
DMX/DMH . . . . . . . . . . . . . . . . . . . . . . 14
CRT . . . . . . . . . . . . . . . . . . . . . . . . . 16
SP A, SP, SP-G . . . . . . . . . . . . . . . . . . . 21
DME, DMS. . . . . . . . . . . . . . . . . . . . . . 13
SQ, SQE . . . . . . . . . . . . . . . . . . . . . . 20
DMM . . . . . . . . . . . . . . . . . . . . . . . . . 13
Pressure tanks . . . . . . . . . . . . . . . . . . . 25
DMX/DMH . . . . . . . . . . . . . . . . . . . . . . 14
MP 1 . . . . . . . . . . . . . . . . . . . . . . . . . 22
Domestic water supply SQE-NE, SP-NE. . . . . . . . . . . . . . . . . . . 22
CH, CHN . . . . . . . . . . . . . . . . . . . . . . 23
CHV booster. . . . . . . . . . . . . . . . . . . . . 25
Dosing
CHV . . . . . . . . . . . . . . . . . . . . . . . . . 24
DME, DMS. . . . . . . . . . . . . . . . . . . . . . 13
CR, CRI, CRN . . . . . . . . . . . . . . . . . . . . 15
DMM . . . . . . . . . . . . . . . . . . . . . . . . . 13
CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . 17
DMX/DMH . . . . . . . . . . . . . . . . . . . . . . 14
DME, DMS . . . . . . . . . . . . . . . . . . . . . 13
DMM. . . . . . . . . . . . . . . . . . . . . . . . . 13
DMX/DMH . . . . . . . . . . . . . . . . . . . . . . 14 Renewable-energy systems
Hydro 2000, Hydro 1000, Hydro Solo, Hydro Multi-E 18 SQFlex. . . . . . . . . . . . . . . . . . . . . . . . 22
JP . . . . . . . . . . . . . . . . . . . . . . . . . . 23
MQ . . . . . . . . . . . . . . . . . . . . . . . . . 24

7
GRUNDFOS ALPHA Pro, GRUNDFOS COMFORT UPS Series 200
GRUNDFOS ALPHA+, UP-N, UP(S)-B Series 100
UPS, UP Series 100 Circulator pumps, canned-rotor type Circulator pumps, canned-rotor type
Circulator pumps, canned-rotor type

H [m] H [m]
8.0
10.0
6.0 4.0
4.0
Series100 2.0
2.0 UP-N, UP(S)-B Series 100
1.0
ALPHA PRO
1.0
0.4 COMFORT
ALPHA+
0.4 0.2
0.2 0.1
0.4
0 1 2 4 6 10 15 0.1
0 0.2 0.5 1 2 4 6 10
Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 10 m3/h Flow, Q: max. 10.5 m3/h Flow, Q: max. 70 m3/h
Head, H: max. 12 m Head, H: max. 7 m Head, H: max. 18 m
Liquid temp.: –25°C to +110°C Liquid temp.: –25°C to +110°C Liquid temp.: –10°C to +120°C
Operat. pres.: max. 10 bar Operat. pres.: max. 10 bar Operat. pres.: max. 10 bar

Applications Applications Applications


Circulation of hot or cold water in Circulation of hot or cold water in Circulation of hot or cold water in
• Heating systems • Domestic hot water recirculation • Heating systems
• Domestic hot water systems • Heating systems • Domestic hot water systems
• Cooling and air-conditioning systems • Domestic hot water systems • Cooling and air-conditioning systems
• Cooling and air-conditioning systems
Features and benefits Features and benefits
• Low-energy Features and benefits • Maintenance-free
Energy labelling up to class A • Maintenance-free • Built-in thermal switch
• Maintenance-free • Low-noise • Low-noise
• Low-noise • Low-energy • Low-energy
• Wide range • Wide range Energy labelling up to class B
• Corrosion-resistant stainless steel, • Single-phase with built-in protection
Options brass pump housing module
• Wide range
• Automatic performance adjustment
• Display of actual power consumption Options
• Automatic night-time duty • 24-hour timer Options
• Simple installation - external plug for • Adjustable thermostat • Protection module
electrical connection • Relay module with fault signal or
• Single-speed or 2- or 3-speed operating output
performance adjustment • Bronze pump housing
• Twin-head versions • Twin-head versions
• Communication via GENIbus or LON

8
GRUNDFOS

GRUNDFOS MAGNA, TP TPE Series 2000


Series 2000
Circulator pumps, canned-rotor type Circulator pumps, close-coupled type Single-stage, centrifugal pumps -
- electronically controlled electronically controlled

H [m] H [m]
200 40
30
100
20
50
10
20
4
10
5 2
10 40 100 200400 1000 4000 2 4 10 20 40 100 200 400
Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 90 m3/h Flow, Q: max. 4600 m3/h Flow, Q: max. 230 m3/h
Head, H: max. 12 m Head, H: max. 170 m Head, H: max. 41 m
Liquid temp.: +15°C to +110°C Liquid temp.: –25°C to +150°C Liquid temp.: –25°C to +140°C
Operat. pres.: max. 10 bar Operat. pres.: max. 25 bar Operat. pres.: max. 16 bar

Applications Applications Applications


Circulation of hot water in Circulation of hot or cold water in Circulation of hot or cold water in
• Heating systems in blocks of flats, • Heating systems • Heating systems
schools, hospitals, hotels, industry etc. • District heating plants • Domestic hot water systems
• Local heating plants • Cooling and air-conditioning systems
Features and benefits • Domestic hot water systems
• Cooling and air-conditioning systems Features and benefits
• Low-noise
• Low-energy • Low-energy
• Wide range Features and benefits • Adaptation to existing operating
• Automatic performance adjustment • Compact design conditions
• Simple installation - no extra • Wide range • Simple installation
equipment or fittings required • Standard motor
• Safe selection • Service-friendly Options
• Various types of shaft seals depending
• Parallel operation
Options on liquid, temperature and pressure
• Wireless remote control, R100
• Stainless steel pump housing • Communication via GENIbus or LON
• Twin-head versions Options • Twin-head versions
• Wireless remote control, R100 • Bronze pump housing
• Communication via GENIbus or LON • Twin-head versions

9
TPE Series 1000 R100 PMU 2000, PCU 2000

Single-stage, centrifugal pumps - Wireless remote control Pump controllers


electronically controlled

H [m]
100
Applications Applications
• All pumps designed for wireless
40 communication PMU 2000
20 • Parallel connection of up to eight pumps
10
Features and benefits • Central reading out of various status
• Simple and quick installation of the information
4 pump
2 • Reading out of various operating and PCU 2000
2 4 10 20 40 100 200 400 fault signals • Fault indication for each pump
Q [m³/h] • Printing out of status information
• External setpoint influence
• Start/stop of system
Technical data
Flow, Q: max. 370 m3/h
Features and benefits
Head, H: max. 90 m
Liquid temp.: –25°C to +140°C • Communication via BUS
Operat. pres.: max. 16 bar • Simple and quick installation

Applications
The pumps are suitable for liquid transfer
in
• District heating plants
• Cooling and air-conditioning systems
• Industrial plants

Features and benefits


• Low-energy
• Adaptation to existing operating
conditions
• Simple installation
• Many control facilities
• Wireless remote control, R100
• Communication via GENIbus or LON

10
GRUNDFOS

Delta Control 2000 NB, NBG NK, NKG

Pump controllers Single-stage standard pumps Single-stage standard pumps

Technical data
No. of pumps: max. 4
Power output: 75 kW
Encl. class: IP 54

Applications
Delta Control 2000 are used for parallel
connection of pumps in
• Heating systems
• Cooling and air-conditioning systems

Technical data Technical data


Features and benefits
• Complete control panel Flow, Q: max. 460 m3/h Flow, Q: max. 2000 m3/h
Head, H: max. 95 m Head, H: max. 150 m
Liquid temp.: –25°C to +140°C Liquid temp.: –25°C to +140°C
Options
Operat. pres.: max. 16 bar Operat. pres.: max. 16 bar
• External communication

Applications Applications
The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer
in in
• District heating plants • District heating plants
• Heating systems for blocks of flats • Water supply systems
• Air-conditioning systems • Air-conditioning systems
• Cooling systems • Cooling plants
• Washdown systems • Industry
• Other industrial systems • Fire fighting systems
• Environment engineering
Features and benefits
• Standard dimensions according to EN Features and benefits
and ISO standards • Standard dimensions according to EN
• Compact design or ISO standards
• Flexible pump range • Wide range
• Standard motor • Robust design
• Adaptable to any application and • Heavy-duty
performance • Flexible motor range
• EN 12 756 shaft seal

Optional
• Various types of shaft seal depending
on liquid, temperature and pressure
• Cast iron or bronze impeller

11
NBE NKE SPK, CHK, MTH, CRK,
MTR, MTA
Single-stage standard pumps - Single-stage standard pumps - Multistage centrifugal immersible pumps
electronically controlled electronically controlled

H [m] H [m]
100 100
60 60
40 40

20 20

10 10
6 6
4 4
10 20 30 60 100 200300 500 10 20 30 60 100 200300 500
Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 460 m3/h Flow, Q: max. 475 m3/h Flow, Q: max. 85 m3/h
Head, H: max. 95 m Head, H: max. 95 m Head, H: max. 238 m
Liquid temp.: –25°C to +140°C Liquid temp.: –25°C to + 140°C Liquid temp.: –20°C to + 90°C
Operat. pres.: max. 16 bar Operat. pres.: max. 16 bar Operat. pres.: max. 25 bar

Applications Applications Applications


The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer
in in in
• Washing systems • Washing systems • Spark machine tools
• Water supply systems • Water supply systems • Grinding machines
• District heating plants • District heating plants • Machining centres
• Cooling and air-conditioning systems • Cooling and air-conditioning systems • Cooling units
• Industrial plants • Industrial plants • Industrial washing machines
• Filtering systems
Features and benefits Features and benefits • Lathes
• Standard dimensions according to EN • Standard dimensions according to DIN • Swarf conveyors
standards standards
• Compact design • Wide range Features and benefits
• Adaptable to any application and • Robust design • Flexible installation length
performance • Heavy-duty • Wide range
• EN 12 756 shaft seal • Many control facilities • Reliability
• Many control facilities • Service-friendly
Options • Simple installation
Optional • Wireless remote control, R100
• Various types of shaft seal depending
on liquid, temperature and pressure
• Cast iron or bronze impeller
• Wireless remote control, R100

12
GRUNDFOS

SPKE, CRKE DME, DMS DMM

Multistage centrifugal immersible pumps - Compact diaphragm dosing pumps Motor-driven diaphragm dosing pumps
electronically controlled

p [bar]
20

10
6
4

1
1 2.5 5 10 20 50 100 200
Q [l/h]

Technical data Technical data Technical data


Flow, Q: max. 22 m3/h Capacity, Q: max. 150 l/h Capacity, Q: max. 990 l/h
Head, H: max. 245 m Pressure, p: max. 18 bar Pressure, p: max. 10 bar
Liquid temp.: –10°C to + 90°C Liquid temp.: max. +50°C Liquid temp.: max. +50°C
Operat. pres.: max. 25 bar

Applications Applications Applications


The pumps are suitable for Injection of chemicals in water and waste Injection of chemicals in water and waste
• Boiler feeding systems water treatment systems, washing sys- water treatment systems, washing sys-
• Pumping of cooling lubricants tems, swimming-pools and process plants tems, swimming-pools and process plants
• Water treatment systems
Features and benefits Features and benefits
Features and benefits • Precise capacity setting in ml or l • Sturdy design
• Wide range • Full diaphragm control • Stroke length capacity control
• Reliability • Stroke speed or -frequency capacity • Leakage-free
• Wireless remote control, R100 control • Motor control option with display and
• Operation panel with display and one- one-touch buttons and following
touch buttons control options:
• Front- or side-fitted operation panel – Pulse control
• Manual/pulse control – Puls division/multiplication
• Control panel lock – Analog 0/4-20 mA control
• 4-20 mA control
• Pulse-/timer-based batch control
• Anti-cavitation function
• Easy calibration function
• Fieldbus communication module
(option)
• Leakage sensor

13
DMX/DMH GP CHI, CHIU

Motor-driven diaphragm dosing pumps Swimming-pool pumps Multistage centrifugal pumps

p [bar]

10

6
4

1
1 20 50 200 500 1150
Q [l/h]

Technical data Technical data Technical data


Capacity, Q: max. 1150 l/h Flow, Q: max. 26 m3/h Flow, Q: max. 14 m3/h
Pressure, p: max. 10 bar Head, H: max. 17.5 m Head, H: max. 57 m
Liquid temp.: max. +50°C Liquid temp.: 0°C to +40°C Liquid temp.: –20°C to +120°C
Operat. pres.: max. 3 bar Operat. pres.: max. 10 bar

Applications Applications Applications


Injection of chemicals in water and waste The pumps are suitable for The pumps are suitable for liquid transfer
water treatment systems, washing sys- • Circulation of swimming-pool water in in
tems, swimming-pools and process plants small and medium sized swimming- • Water treatment systems
pools • Industrial washing and dishwashing
Features and benefits machines
• Sturdy design Features and benefits • Pressure boosting of process water
• Stroke length capacity control • Built-in motor protection • Heating and cooling in industrial
• Leakage-free processes
• Stainless steel shaft
Motor control option with display and one- • Air-conditioning systems
• Low sound level
touch buttons and following • Self-priming down to 2 m • Airwashing, moisturization,
control options: humidification (softened water)
• Corrosion resistant materials
– Pulse control • Water supply and pressure boosting
• No need for special service tools
– Puls division/multiplication • Quick and easy to repair (potable water, also slightly chlorinated)
– Analog 0/4-20 mA control
Options Features and benefits
• Compact design
• Integrated heating unit
• Wide range
• Level sensor
• Control panels • Suitable for slightly aggressive liquids
• Low noise
• Leakage-free (CHIU only)

14
GRUNDFOS

CHIE CR, CRI, CRN CR, CRN high pressure

Multistage centrifugal pumps - Multistage centrifugal pumps Multistage centrifugal pumps


electronically controlled

H [m] H [m] H [m]


60
40 200 400
150
20 200
100
10
100
6 60
4 60
40
2 40

1 20 20
1 2 4 6 8 10 15 20 1 2 4 6 10 20 40 100 200 1 2 4 6 10 20 40 100 200
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 14 m3/h Flow, Q: max. 120 m3/h Flow, Q: max. 120 m3/h
Head, H: max. 58 m Head, H: max. 330 m Head, H: max. 480 m
Liquid temp.: –20°C to +110°C Liquid temp.: –40°C to +180°C Liquid temp.: –30°C to +120°C
Operat. pres.: max. 10 bar Operat. pres.: max. 33 bar Operat. pres.: max. 50 bar

Applications Applications Applications


The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer
in in in
• Cooling systems • Washing systems • Washing systems
• Industrial washing systems • Cooling and air-conditioning systems • Water treatment systems
• Aquafarms • Water supply systems • Industrial plants
• Fertilizer systems • Water treatment systems • Boiler feeding systems
• Dosing systems • Fire fighting systems
• Industrial plants • Industrial plants Features and benefits
• Boiler feeding systems
• Reliability
Features and benefits • High pressures
• Compact design Features and benefits • Service-friendly
• Wide range • Reliability • Space-saving
• Suitable for slightly aggressive liquids • High efficiency • Suitable for slightly aggressive liquids
• Many control facilities • Service-friendly • Single pump solution enabling high
• Space-saving pressure
Options • Suitable for slightly aggressive liquids
• Wireless remote control, R100 Options
Options • Dry-running protection and motor
• Dry-running protection and motor protection via LiqTec
protection via LiqTec

15
CRT LiqTec CV, CPV, CPH

Multistage centrifugal pumps Control and monitoring unit Multistage centrifugal pumps

H [m]
Applications
200 • Monitoring and protection of pumps and
processes
100

60 Features and benefits


40 • Protection against dry running
• Protection against liquid temperatures
20 exceeding 130°C ±5°C
1 2 4 6 8 10 20 30 • Protection against too high motor
Q [m³/h] temperatures
• Manual or automatic restarting possible
Technical data from a remote PC Technical data
Flow, Q: max. 22 m3/h • Simple installation - plug and play Flow, Q: max. 560 m3/h
Head, H: max. 250 m technology Head, H: max. 200 m
Liquid temp.: –20°C to +120°C • Robust sensor Liquid temp.: –15°C to +120°C
Operat. pres.: max. 25 bar Operat. pres.: max. 20 bar

Applications Applications
The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer
in in
• Process water systems • Washing systems
• Washing in cleaning systems • Cooling and air-conditioning systems
• Sea water systems • Water supply systems
• Pumping of acids and alkalis • Water treatment systems
• Ultra filtration systems • Fire fighting systems
• Reverse osmosis systems • Industrial plants
• Swimming baths • Boiler feeding systems

Features and benefits Features and benefits


• High corrosion resistance • Low-speed (4-pole motors)
• Reliability • Heavy-duty
• High efficiency • Low-noise
• Service-friendly • Vertical and horizontal installation
• Space-saving

Options
• Dry-running protection and motor
protection via LiqTec

16
GRUNDFOS

CRE, CRIE, CRNE Euro-HYGIA® Contra

Multistage centrifugal pumps - Single-stage, end-suction sanitary pumps Single- and multi-stage, end-suction sani-
electronically controlled tary pumps

H [m] H [m] H [m]


200 100 150
100 60 100
40
40 60
20 20 40
10 10 20
4 6
2 4 10
2 4 6 10 20 40 60 100 10 15 20 30 40 60 100 150 5 10 15 20 30 40 60
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 120 m3/h Flow, Q: max. 130 m3/h Flow, Q: max. 55 m3/h
Head, H: max. 250 m Head, H: max. 75 m Head, H: max. 170 m
Liquid temp.: –40°C to +180°C Operat. temp.: +95°C Operat. temp.: +95°C
Operat. pres.: max. 33 bar (+150°C on request) (+150°C on request)
Operat. pres.: max. 16 bar Operat. pres.: max. 25 bar
Applications
The pumps are suitable for liquid transfer Applications Applications
in • Liquid transfer in breweries and dairies • Liquid transfer in breweries and dairies
• Washing systems • Mixing in soft drink applications • Carbonising systems
• Cooling and air-conditioning systems • Food processing plants • Food processing plants
• Water supply systems • Pure water systems (WFI) • Purification systems
• Water treatment systems • Process pumping in pharmaceutical • Pure water systems (WFI)
• Fire fighting systems industry • Surface treatment systems
• Industrial plants • CIP (Cleaning-In-Place) systems. • CIP feeding systems.
• Boiler feeding systems
Features and benefits Features and benefits
Features and benefits • Unique hygienic design (QHD, EHEDG • Unique hygienic design (QHD, EHEDG
• Wide range and 3A standards) and 3A standards)
• Reliability • CIP and SIP capable (DIN EN 12462) • CIP and SIP capable (DIN EN 12462)
• In-line design • Customised solutions • High efficiency
• High efficiency • Materials: AISI 316L (DIN EN 1.4404/ • Materials: AISI 316L (DIN EN 1.4404/
• Service-friendly 1.4435) 1.4435).
• Space-saving • Gentle media handling.
• Many control facilities Options
Options • Electronically speed controlled versions
Options • Electronically speed controlled versions • ATEX-certified pumps
• Wireless remote control, R100 • ATEX-certified pumps • Fully drainable versions.
• Wide range impeller designs.

17
SIPLA MAXA and MAXANA Hydro 2000, Hydro 1000,
Hydro Solo, Hydro Multi-E
Single-stage, self-priming side-channel End-suction process pumps Complete pressure boosting systems
sanitary pumps

H [m] H [m]
60 100
40 60
30 40
30
20
20
10 10

5 5
5 10 20 30 40 60 100 20 40 60 100 200 400 1000
Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow, Q: max. 90 m3/h Flow, Q: up to max. 800 m3/h Flow, Q: max. 720 m3/h
Head, H: max. 50 m Head, H: up to max. 97 m Head, H: max. 160 m
Operat. temp.: +95°C Operat. temp.: +95°C Liquid temp.: 0°C to +70°C
(+140°C on request) (+150°C on request) Operat. pres.: max. 16 bar
Operat. pres.: max. 10 bar Operat. pres.: max. 10 bar
Applications
Applications Applications Hydro 2000 are suitable for pressure
• CIP return pumping • Gentle pumping of mash and wort for boosting in
• Transfer of glycerine beer filtration (hot side) • Water supply systems
• Transfer of yeast • Liquid transfer in dairies • Irrigation systems
• Transfer of whey. • Water treatment plants • Water treatment systems
• Chemical and environmental handling • Fire fighting systems
Features and benefits systems • Industrial plants
• Liquids with high content of solid parti-
• Meets the 3A hygienic standard
cles. Features and benefits
• High air-content handling
• Efficient priming. • Constant pressure
Features and benefits • Simple installation
Options • Optimised hydraulics • Low-energy
• Gentle product handling • Wide range
• Electronically speed controlled versions
• Materials: AISI 316 (DIN EN 1.4404)
• ATEX-certified pumps
• Fully cleanable versions. • Service and repair friendly. Options
• External communication, Control 2000
Options
• Electronically speed controlled versions
• ATEX-certified pumps
• Electro-polished versions
• Double mechanical shaft seals (tan-
dem/back-to-back).

18
GRUNDFOS

Control 2000 BMP BM, BMB

Pump controllers Piston pumps designed for transport of 4", 6", 8" booster modules
fluids under high pressure.

H [m]
Applications Technical data
400
Control 2000 is suitable for parallel Flow, Q: max. 10.2 m3/h
connection of pumps in Head, H: max. 1630 m 200
• Water supply systems Liquid temp.: 3°C to +50°C 100
• Irrigation systems Operat. pres.: max. 160 bar 60
• Water treatment systems 40
• Fire fighting systems Applications 20
• Industrial plants
BMP pumps are suitable for a variety of 10
applications ranging from pumping of 1 2 4 10 20 40 100 200 400
Features and benefits potable water to pumping of chemicals. Q [m³/h]
• Complete control panel • Cleaning/washing
• Injecting Technical data
Options • Misting Flow, Q: max. 260 m3/h
• External communication • Processing Head, H: max. 430 m
• Desalination of brackish water and Liquid temp.: 0°C to +40°C
seawater Operat. pres.: max. 80 bar

Features and benefits Applications


• High efficiency The booster modules are suitable for
• Small and light pump pressure boosting in
• Generates insignificant pulsations in • Reverse osmosis systems
the discharge line • Water supply systems
• No preventive maintenance required • Water treatment systems
• Long service life • Industrial plants
• Few wear parts
• Wide speed control range
Features and benefits
• Extreme recirculation capability without
• Various material versions
overheating (up to 90%)
• Low-noise
• Lubricated by the pumped liquid
• Simple installation
• Modular design
• Compact design
• Leakage-free

19
BME, BMET BMEX SQ, SQE

High-pressure booster systems Grundfos booster system BMEX is 3" submersible pumps
designed for energy recovery in Sea
Water Reverse Osmosis (SWRO)

[kWh]
BMEX / BMET
5.0

4.5

BMET
4.0

3.5

3.0

2.5

2.0
BMEX / BMET
1.5 BMEX

1.0

0.5

0.0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800
Q [m³/day]
Permeate

Technical data Technical data Technical data


Flow, Q: max. 95 m3/h Permeate per day: 500 to 2500 m3 Flow, Q: max. 9 m3/h
Head, H: max. 700 m Head, H: max. 810 m Head, H: max. 210 m
Liquid temp.: 0°C to +40°C Ambient temp.: +40°C Liquid temp.: 0°C to +40°C
Operat. pres.: max. 70 bar Operat. pres.: max. 80 bar Installation depth: max. 150 m

Applications Applications Applications


The booster systems are suitable for • Desalination of brakish water and The pumps are suitable for
pressure boosting in seawater • Domestic water supply systems
• Reverse osmosis systems • Groundwater supply to waterworks
• Water supply systems Features and benefits • Irrigation in horticulture and agriculture
• Water treatment systems • Groundwater lowering
• Energy recovery up to 60%, compared
• Industrial plants • Industrial applications
to conventional systems, resulting in
short payback period
Features and benefits • Corrosion- and wear-resistant internal Features and benefits
• High-pressure/high-flow ceramic com-ponents • Integrated dry-running protection
• Low-energy • Couplings for easy installation • Soft start
• Simple installation • High-grade stainless steel used on • Over- and undervoltage protection
• Compact design frame and manifold • High efficiency
• Large flows and high heads
• Motor and bearings are standard com- Options
ponents • SQE can be protected, monitored and
• Maintenance-free shaft seal
controlled by CU 300 and CU 301 via
• V-belt drive with high efficiency
R100.
• Easy to dismantle for service

20
GRUNDFOS

SP A, SP, SP-G MS motors MMS motors

4", 6", 8", 10", 12" submersible pumps Stainless steel 4" and 6" submersible Stainless steel 6", 8", 10", 12" rewindable
motors submersible motors

H [m]
600 Motor sizes Motor sizes
400 4" motor: 0.37 to 7.5 kW 6" motor: 3.7 to 37 kW
200 6" motor: 5.5 to 30 kW 8" motor: 22 to 110 kW
10" motor: 75 to 190 kW
100
60 Applications 12" motor: 147 to 250 kW
40 The Grundfos MS submersible motors
20 can be fitted on all Grundfos SP A, SP Applications
10 pumps and can be used in the high-pres- The Grundfos MMS submersible motors
1 2 4 10 20 40 100 200 600 sure booster modules, type BM and BMB. can be fitted on all Grundfos SP and SP-G
Q [m³/h] pumps.
Features and benefits
Technical data
• Overprotection by means of a built-in Features and benefits
Flow, Q: max. 470 m3/h Tempcon temperature transmitter • Wide range of rewindable motors
Head, H: max. 670 m • Standardized NEMA head and shaft • Easily rewinded
Liquid temp.: 0°C to +60°C end • Protection against upthrust
Installation depth: max. 600 m • Completely encapsulated in stainless • High efficiency
steel • 6" and 8" have standardized NEMA
Applications • Liquid cooled and has liquid lubricated head and shaft end
The pumps are suitable for bearings • Mechanical shaft seal
• Groundwater supply to waterworks ceramic/carbon or SiC/SiC
• Irrigation in horticulture and agriculture Options • PVC or PE/PA windings
• Groundwater lowering • Material variants available
• Pressure boosting Options
• Industrial applications • Material variants available
• Overtemperature protection via Pt100
Features and benefits
• High efficiency
• Long service life as all components are
stainless steel
• Motor protection via CU 3

Options
• Data can be monitored and controlled
via CU 3/R100

21
SQE-NE, SP-NE MP 1 SQFlex

Environmental pumps Environmental pumps Renewable-energy based water supply


systems

H [m]
140
120
100
80
60
40
20
0
0 20 40 60 80 100
Q [m³/day]

Technical data Technical data Technical data


Flow, Q: max. 22 m3/h Flow, Q: max. 2.4 m3/h Flow, Q: max. 90 m3/day
Head, H: max. 215 m Head, H: max. 95 m Head, H: max. 120 m
Liquid temp.: 0°C to +40°C Liquid temp.: 0°C to +35°C Liquid temp.: 0°C to +40°C
Instal. depth: max. 600 m Voltage supply: 30-300 VDC or
1x90-240 V, 50/60
Applications Applications Hz
Instal. depth: max. 150 m
The pumps are suitable for The pumps are suitable for
• Pumping up contaminated groundwater • Sampling
• Sampling Applications
• Remedial pumping Features and benefits The SQFlex systems are suitable for
remote locations, such as:
• Compact design
Features and benefits • Villages, schools, hospitals, single-
• Fit into 50 mm boreholes
SQE-NE family houses
• Farms and irrigation of greenhouses
• Same features and benefits as SQE
• Game parks and game farms
SP-NE
• Same features and benefits as SP • Conservation areas

Features and benefits


• Energy supply: Solar modules, wind
turbine, generator or batteries
• Simple installation
• Reliable water supply
• Virtually no maintenance
• Expansion possibilities
• Cost-efficient pumping
• Dry-running protection

22
GRUNDFOS

CU 3, CU 300, CU 301 JP CH, CHN

Control and monitoring units Self-priming jet pumps Multistage centrifugal pumps

Applications
• Monitoring and protection of pump
installations

Features and benefits


• Protection against dry running and too
high motor temperature
• Constant monitoring of pump energy
consumption
• Reading out of operating data via R100

Technical data Technical data


Options
• Connection to large control systems via Flow, Q: max. 5 m3/h Flow, Q: max. 14 m3/h
bus-communication Head, H: max. 48 m Head, H: max. 55 m
• Connection of sensors enabling control Liquid temp.: 0°C to +55°C Liquid temp.: 0°C to +90°C
based on sensor signals Operat. pres.: max. 6 bar Operat. pres.: max. 10 bar

Applications Applications
The pumps are suitable for liquid transfer The pumps are suitable for liquid transfer
in in
• Households • Pressure boosting systems
• Gardens • Domestic water supply systems
• Hobby activities • Cooling systems
• Agriculture • Air-conditioning systems
• Horticulture • Horticultural irrigation systems
• Small industries • Small industrial water supply systems

Features and benefits Features and benefits


• Self-priming • Compact design
• Stable operation even in case of air • Robust design
pockets in the liquid • Full stainless steel design (CHN only)
• Low-noise
Options
• Automatic start/stop when equipped Options
with Presscontrol • Booster sets for domestic water supply
• Booster sets for small-scale water • Automatic start/stop when equipped
supply with Presscontrol

23
MQ RMQ CHV

Multistage centrifugal self-priming pumps Rainwater unit for monitoring and control Multistage centrifugal pumps
of rainwater systems

Technical data Technical data Technical data


Flow, Q: max. 5 m3/h Flow, Q: max. 5 m3/h Flow, Q: max. 8 m3/h
Head, H: max. 48 m Head, H: max. 48 m Head, H: max. 93 m
Liquid temp.: 0°C to +35°C Liquid temp.: 0°C to +35°C Liquid temp.: 0°C to +90°C
Operat. pres.: max. 7.5 bar Operat. pres.: max. 7.5 bar Operat. pres.: max. 12 bar

Applications Applications Applications


The pumps are suitable for liquid transfer The rainwater unit is suitable for the The pumps are suitable for liquid transfer
in transfer of water from water collection and in
• Single- or two-family houses utilisation systems in: • Pressure boosting systems
• Weekend cottages • Single- or two-family houses • Domestic water supply systems
• Farms • Weekend cottages • Cooling systems
• Greenhouses • Farms • Air-conditioning systems
• Gardens and greenhouses • Horticultural irrigation systems
Features and benefits • Small industrial water supply systems
• All-in-one pressure booster unit Features and benefits
• Easy to install • Automatic changeover between rain- Features and benefits
• Easy to operate water tank and integrated main water • Compact design
• Self-priming tank • Robust design
• Dry-running protection with automatic • Manual changeover between rainwater • Low-noise
reset tank and integrated main water tank • Space-saving
• Low-noise • Acoustic/visual alarm in case of over-
• Maintenance-free flow in integrated main water tank

Options
• Control of additional booster pump
• Backflow sensor in case of overflow in
sewers

24
GRUNDFOS

CHV booster Pressure tanks Unilift CC, KP, AP12,


AP35/50, AP35B/50B
Vertical pressure booster systems Diaphragm and bladder tanks
Submersible drainage and effluent pumps

Technical data
Tank size: 8-3000 l
Liquid temp.: max. +90°C
Operat. pres.: max. 16 bar

Applications
The diaphragm and bladder tanks are
used in
• Water supply systems in housing
• Pressure boosting systems in housing
Technical data • Agriculture Technical data
Flow, Q: max. 16 m3/h • Horticulture Flow, Q: max. 35 m3/h
Head, H: max. 93 m • Industrial systems Head, H: max. 18 m
Liquid temp.: 0°C to +40°C Liquid temp.: 0°C to +55°C
Operat. pres.: max. 10 bar Features and benefits Particle size: ø10-50 mm
• Optimal water supply
Applications • Reduced number of pump starts Applications
The booster systems are suitable for • Ideal for drinking water The pumps are suitable for
pressure boosting in • drainage of flooded cellars
• Small waterworks • pumping of household wastewater
• Small blocks of flats • groundwater lowering
• Hotels • emptying of swimming-pools and
• Stores excavations
• Light industry • drainage of drain wells
• Hospitals • emptying of tanks and reservoirs
• Schools
• Large houses Features and benefits
• Simple installation
Features and benefits • Service- and maintenance-free
• One- or two-pump system
• User-friendly controllers Options
• Reliability • Unilift CC is suitable for low suction
• High efficiency
• Unilift AP35/50 and AP35B/50B has
• Service-friendly
vortex impeller
• Unilift AP35B and AP50B has auto-
Options coupling and horizontal outlet
• Overpressure protection
• Dry-running protection

25
SEG AMD, AMG, AFG DW

Grinder pumps Mixers and flowmakers Contractor pumps

H [m]
Technical data
100
Liquid temp.: +5°C to +40°C
60
pH value: 4 to 10
40
Axial thrust: 160 to 3931 N
Max. dynamic 20
viscosity: 500 mPa s
10
Max. density: 1060 kg/m3
Max. installation
4
depth: 20 m 1 2 4 10 20 40 100 400
Q [m³/h]
Applications
Technical data The mixers and flowmakers are designed
Technical data
Flow, Q: max. 5 l/s for mixing, i.e. homogenization and Flow, Q: max. 300 m3/h
Head, H: max. 47 m suspension, of liquids in Head, H: max. 100 m
Liquid temp.: 0°C to +40°C • Municipal wastewater treatment Liquid temp.: 0°C to +40°C
systems
• Industrial processes
Applications • Sludge treatment systems Applications
The pumps are suitable for the pumping of • Agriculture The pumps are suitable for liquid transfer
wastewater with toilet waste through pipes • Biogas plant in
of 40 mm in diameter and upwards. The mixers and flowmakers are equipped • Tunnels
with propellers made of stainless steel or • Mines
Features and benefits composite material with a diameter • Quarries
between 180 mm and 2300 mm and a • Gravel pits
• Service-friendly
rotation speed between 22 min-1 and • Fish ponds
• Installation on foot or auto-coupling
1400 min-1. • Building sites
• Continuous operation with fully sub-
merged pump
• Built-in motor protection Features and benefits Features and benefits
• SmartTrim • Wide range of flexible installation • Extremely hard-wearing due to
• Improved grinder system accessories specially selected materials
• Totally sealed cable plug • Easy to maintain and service without • Simple installation
use of special tools • Service-friendly
Options • Electronic leak sensor in gearbox/shaft
seal housing
• Wide range of accessories
• Shaft seal protected against abrasive
• Monitoring and control of one or several
materials
pumps
• Self-cleaning stainless steel or
polyamide propellers

26
GRUNDFOS

Lifting stations Sololift+ Liftaway B and C

Complete pumping stations Domestic lifting stations Domestic lifting stations

H [m]
Applications Technical data for Liftaway B
30 Sololift+ can be used for: Inlet dimension: 3 x DN 100
20 • extra bathrooms Discharge connection: DN 40
• basement installations Effective volume: 40 l
• low-cost bathrooms in holiday cottages
10
• added facilities in hotels and guest- Technical data for Liftaway C
6 houses Inlet dimension: 3 x DN 100
• bathrooms for the elderly or the disab-
4 + 1 x DN 40/50
1 10 20 30 50 led
Discharge connection: DN 40
Q [l/s] • renovation of offices and other commer- Effective volume 13 l
cial buildings.
Technical data
Applications
Flow, Q: max. 60 l/s (216 m3/h), Features and benefits
Liftaway B and C can be used:
recom. 31 l/s (110 m3/h) • Unique design with smooth line and
• as draining well for the collection of
Head, H: max. 29 m rounded edges - fits every modern drainage and surface water
Liquid temp.: 0°C to +40°C bathroom environment
• for the collection and pumping of waste-
Discharge diameter: DN 80 to DN 100 • Plug-and-go product - all you need in
water from basement and laundry
one package
rooms below sewer level
• Low noise level
Applications • for the collection and pumping of waste-
• Discharge pipe connection in the side
The lifting stations are suitable for use in water from wash basins, washing
ensures easy maintenance
• Single- and multi-family houses machines, showers and floor drains to
• Flexible discharge pipe adapters for sewer level
• Weekend cottages and summer houses
outer pipe diameters of ø23, ø25, ø28
• Restaurants • for the collection and pumping of rain
and ø32 mm
• Small hotels water.
• Thermal overload switch
• Sewage systems in the open country
• Cover without screws - easy service
• Percolation systems Features and benefits
• Easy connection of extra sanitary appli-
ances • To be fitted with pumps from the
Features and benefits Unilift KP and AP range
• Ready for installation
CWC-3
• Flexible pipe connection Liftaway B
• Cable plug connection • Especially designed for wall-hung
toilets • Telescopic part for easy height adjust-
• Unique clamp assembly system
• Compact and slim for easy integration ment
• Single-channel and vortex impellers
into the wall • Flexible and easy installation
• Solids passage up to 100 mm
• Low risk of clogging
• Minimum downtime C-3 Liftaway C
• Low operating costs • Especially designed for high liquid tem- • Functional design and easy to clean
• Liquidless motor cooling perature wastewater from washing • Overflow protection device
• Unique cartridge shaft seal machine or dishwasher • Active carbon filter to eliminate odours
• Modular design • Compact and slim for easy installation • Compact and slim for easy installation
under a washbasin or in a closet under a wash basin or in a closet

27
Conlift S pumps SRP pumps

Pump for condensate water Supervortex pumps, single- or Submersible re-circulation pumps
multichannel impeller pumps

H [m] H [m]
Technical data
100 2.0
Flow: max. 630 l/h
60 1.5
Head H: max. 5.3 m
Liquid temp.: max. 35°C short
40 1.0
0.8
periods 80°C DN 300 DN 500 DN 800
20 0.6
pH: min 2.7
10 0.4
Container volume: 2.6 l
Effective volume: 0.85 l 6
4 0.2
10 20 40 100 200 400 1000 3000 100 200 400600 1000 2000
Applications Q [l/s] Q [l/s]
The Conlift is designed for safe removal of
condensate from: Technical data Technical data
• boilers up to 200 kW Flow, Q: max. 2500 l/s Flow, Q: max. 1430 l/s
• air-conditioning systems Head, H: max. 116 m (5130 m3/h)
• cooling and refrigeration systems Liquid temp.: 0°C to +40°C Head, H: max. 2.1 m
• air dehumidifiers Discharge diameter: DN 80 to DN 500 Liquid temp.: 5°C to +40°C
• evaporators Particle size: max. ø145 mm Discharge pipe
diameter: DN300, DN500 and
Features and benefits Applications DN800
• Built-in on/off control via 2 pressure The pumps are suitable for the following
switch ensures high security applications Applications
• Built-in alarm and potentialfree contact • Transfer of wastewater The pumps are suitable for the following
• Angular mounting brackets to counter- • Transfer of raw water applications
act buoancy • Pumping of sludge-containing water • Re-circulation of sludge within sewage
• LGA approval • Pumping of industrial effluent treatment plants
• Modern design • Storm water pumping
• Easy to clean Features and benefits
• Wide range Features and benefits
• SmartTrim • High efficiency stainless steel propeller
• Operation with/without cooling jacket • Totally submerged installations
• Submerged or dry installation • Built-in motor protection
• Different types of impellers
• Built-in motor protection
Options
• Control and protection systems
Options
• Control and protection systems
• External cooling water
• External seal flush system
• Sensors for monitoring of pump condi-
tions

28
GRUNDFOS

SEN SE DP, EF, SE1 and SEV

Submersible stainless steel pumps Heavy duty submersible pumps Drainage, effluent and sewage pumps

H [m] H [m] H [m]


60
40
40 30 20
30 20
10
20
10 6
4
10 6
4 2
6 3
4 2 1
10 20 30 50 100 200 300 5 10 15 20 30 40 60 100 1 2 3 5 7 10 30
Q [l/s] Q [l/s] Q [l/s]

Technical data Technical data Technical data


Flow, Q: max. 215 l/s Flow, Q: max. 88 l/s Flow, Q: max. 19.5 l/s
(774 m3/h) (315 m3/h) (70 m3/h)
Head, H: max. 50 m Head, H: max. 45 m Head, H: max. 25 m
Liquid temp.: 0°C to +40°C Liquid temp.: 0°C to +40°C Liquid temp.: 0°C to +40°C
Discharge diameter: DN 80 to DN 250 Discharge diameter: DN 65 to DN 150 Discharge diameter: Rp 2 to DN 65

Applications Applications Applications


The pumps are suitable for the following The pumps are suitable for the following The pumps are suitable for:
applications applications • Drainage
• Transfer of wastewater and raw water • Wastewater • Effluent
• Pumping of highly aggressive liquids • Process water • Wastewater
• Pulp and paper industries • Unscreened raw sewage • Process water
• Sludge-containing sewage • Domestic sewage
Features and benefits
Features and benefits Features and benefits
• SmartTrim
• Operation with/without cooling jacket • Cable plug connection • Cable plug connection
• Unique clamp assembly system
• Submerged or dry installation • Unique clamp connection
• Single-channel and vortex impellers
• Different types of impellers • Single-channel and vortex impellers
• Built-in motor protection • Solids passage up to 100 mm • Solids passage up to 65 mm
• Low risk of clogging
• Various executions in stainless steel • Unique cartridge shaft seal
• Minimum downtime
• Liquids with a pH value between • Modular design
2 and 14 • Low operating costs • Minimum downtime
• Liquidless motor cooling
• Unique cartridge shaft seal
Options • Modular design Options
• Control and protection systems • Control and protection systems
• External cooling water Options • Motor operation control
• External seal flush system
• Control and protection systems
• Sensors for monitoring of pump condi-
• Motor operation control
tions • Sensors for monitoring pumps condition

29
30
GRUNDFOS

31
Denmark France Korea Spain
GRUNDFOS DK A/S Pompes GRUNDFOS Distribution S.A. GRUNDFOS Pumps Korea Ltd. Bombas GRUNDFOS España S.A.
Poul Due Jensens Vej 7A Parc d’Activités de Chesnes 6th Floor, Aju Building 679-5 Camino de la Fuentecilla, s/n
DK-8850 Bjerringbro 57, rue de Malacombe Yeoksam-dong, Kangnam-ku, 135-916 E-28110 Algete (Madrid)
Tlf.: +45-87 50 50 50 F-38290 St. Quentin Fallavier (Lyon) Seoul Korea Tel.: +34-91-848 8800
Telefax: +45-87 50 51 51 Tél.: +33-4 74 82 15 15 Phone: +82-2-5317 600 Telefax: +34-91-628 0465
E-mail: info_GDK@grundfos.com Télécopie: +33-4 74 94 10 51 Telefax: +82-2-5633 725
www.grundfos.com/DK Sweden
Germany Malaysia GRUNDFOS AB
Argentina GRUNDFOS GMBH GRUNDFOS Pumps Sdn. Bhd. Box 63, Angeredsvinkeln 9
Bombas GRUNDFOS de Argentina S.A. Schlüterstr. 33 7 Jalan Peguam U1/25 S-424 22 Angered
Ruta Panamericana km. 37.500 Lote 34A 40699 Erkrath Glenmarie Industrial Park Tel.: +46-771-32 23 00
1619 - Garin Tel.: +49-(0) 211 929 69-0 40150 Shah Alam Telefax: +46-31 331 94 60
Pcia. de Buenos Aires Telefax: +49-(0) 211 929 69-3799 Selangor
Phone: +54-3327 414 444 e-mail: infoservice@grundfos.de Phone: +60-3-5569 2922 Switzerland
Telefax: +54-3327 411 111 Service in Deutschland: Telefax: +60-3-5569 2866 GRUNDFOS Pumpen AG
e-mail: kundendienst@grundfos.de Bruggacherstrasse 10
Australia Mexico CH-8117 Fällanden/ZH
GRUNDFOS Pumps Pty. Ltd. Greece Bombas GRUNDFOS de Mexico S.A. de Tel.: +41-1-806 8111
P.O. Box 2040 GRUNDFOS Hellas A.E.B.E. C.V. Telefax: +41-1-806 8115
Regency Park 20th km. Athinon-Markopoulou Av. Boulevard TLC No. 15
South Australia 5942 P.O. Box 71 Parque Industrial Stiva Aeropuerto Taiwan
Phone: +61-8-8461-4611 GR-19002 Peania Apodaca, N.L. 66600 GRUNDFOS Pumps (Taiwan) Ltd.
Telefax: +61-8-8340 0155 Phone: +0030-210-66 83 400 Mexico 14, Min-Yu Road
Telefax: +0030-210-66 46 273 Phone: +52-81-8144 4000 Tunglo Industrial Park
Austria Telefax: +52-81-8144 4010 Tunglo, Miao-Li County
GRUNDFOS Pumpen Vertrieb Ges.m.b.H. Hong Kong Taiwan, R.O.C.
Grundfosstraße 2 GRUNDFOS Pumps (Hong Kong) Ltd. Netherlands Phone: +886-37-98 05 57
A-5082 Grödig/Salzburg Unit 1, Ground floor GRUNDFOS Nederland B.V. Telefax: +886-37-98 05 70
Tel.: +43-6246-883-0 Siu Wai Industrial Centre Postbus 104
Telefax: +43-6246-883-30 29-33 Wing Hong Street & NL-1380 AC Weesp Thailand
68 King Lam Street, Cheung Sha Wan Tel.: +31-294-492 211 GRUNDFOS (Thailand) Ltd.
Belgium Kowloon Telefax: +31-294-492244/492299 947/168 Moo 12, Bangna-Trad Rd., K.M.
N.V. GRUNDFOS Bellux S.A. Phone: +852-27861706/27861741 3,
Boomsesteenweg 81-83 Telefax: +852-27858664 New Zealand Bangna, Phrakanong
B-2630 Aartselaar GRUNDFOS Pumps NZ Ltd. Bangkok 10260
Tél.: +32-3-870 7300 Hungary 17 Beatrice Tinsley Crescent Phone: +66-2-744 1785 ... 91
Télécopie: +32-3-870 7301 GRUNDFOS Hungária Kft. North Harbour Industrial Estate Telefax: +66-2-744 1775 ... 6
Park u. 8 Albany, Auckland
Brazil H-2045 Törökbalint, Phone: +64-9-415 3240 Turkey
GRUNDFOS do Brasil Ltda. Phone: +36-34 520 100 Telefax: +64-9-415 3250 GRUNDFOS POMPA SAN. ve TIC. LTD.
Rua Tomazina 106 Telefax: +36-34 520 200 STI
CEP 83325 - 040 Norway Bulgurlu Caddesi no. 32
Pinhais - PR India GRUNDFOS Pumper A/S TR-81190 Üsküdar Istanbul
Phone: +55-41 668 3555 GRUNDFOS Pumps India Private Limited Strømsveien 344 Phone: +90 - 216-4280 306
Telefax: +55-41 668 3554 Flat A, Ground Floor Postboks 235, Leirdal Telefax: +90 - 216-3279 988
61/62 Chamiers Aptmt N-1011 Oslo
Canada Chamiers Road Tlf.: +47-22 90 47 00 United Arab Emirates
GRUNDFOS Canada Inc. Chennai 600 028 Telefax: +47-22 32 21 50 GRUNDFOS Gulf Distribution
2941 Brighton Road Phone: +91-44 432 3487 P.O. Box 16768
Oakville, Ontario Telefax: +91-44 432 3489 Poland Jebel Ali Free Zone
L6H 6C9 GRUNDFOS Pompy Sp. z o.o. Dubai
Phone: +1-905 829 9533 Indonesia ul. Klonowa 23 Phone: +971-4- 8815 166
Telefax: +1-905 829 9512 PT GRUNDFOS Pompa Baranowo k. Poznania Telefax: +971-4-8815 136
Jl. Rawa Sumur III, Blok III / CC-1 PL-62-081 Przezmierowo
China Kawasan Industri, Pulogadung Phone: +48-61-650 13 00 United Kingdom
GRUNDFOS Pumps (Shanghai) Co. Ltd. Jakarta 13930 Telefax: +48-61-650 13 50 GRUNDFOS Pumps Ltd.
22 Floor, Xin Hua Lian Building Phone: +62-21-460 6909 Grovebury Road
755-775 Huai Hai Rd, (M) Telefax: +62-21-460 6910/460 6901 Portugal Leighton Buzzard/Beds. LU7 8TL
Shanghai 200020 Bombas GRUNDFOS Portugal, S.A. Phone: +44-1525-850000
PRC Ireland Rua Calvet de Magalhães, 241 Telefax: +44-1525-850011
Phone: +86-512-67 61 11 80 GRUNDFOS (Ireland) Ltd. Apartado 1079
Telefax: +86-512-67 61 81 67 Unit 34, Stillorgan Industrial Park P-2770-153 Paço de Arcos U.S.A.
Blackrock Tel.: +351-21-440 76 00 GRUNDFOS Pumps Corporation
Czech Republic County Dublin Telefax: +351-21-440 76 90 17100 West 118th Terrace
GRUNDFOS s.r.o. Phone: +353-1-2954926 Olathe, Kansas 66061
Cajkovského 21 Telefax: +353-1-2954739 Russia Phone: +1-913-227-3400
779 00 Olomouc OOO GRUNDFOS Telefax: +1-913-227-3500
Phone: +420-585-716 111 Italy Shkolnaya 39
Telefax: +420-585-438 906 GRUNDFOS Pompe Italia S.r.l. RUS-109544 Moscow
Via Gran Sasso 4 Phone: +7-095 564 88 00, +7-095 737
Finland I-20060 Truccazzano (Milano) 3000
OY GRUNDFOS Pumput AB Tel.: +39-02-95838112 Telefax: +7-095 564 88 11, +7-095 737
Mestarintie 11 Telefax: +39-02-95309290/95838461 7536
Piispankylä e-mail: grundfos.moscow@grundfos.com
FIN-01730 Vantaa (Helsinki) Japan
Phone: +358-9 878 9150 GRUNDFOS Pumps K.K. Singapore
Telefax: +358-9 878 91550 1-2-3, Shin Miyakoda GRUNDFOS (Singapore) Pte. Ltd.
Hamamatsu City 24 Tuas West Road
Shizuoka pref. 431-21 Jurong Town
Phone: +81-53-428 4760 Singapore 638381
Telefax: +81-53-484 1014 Phone: +65-6865 1222
Telefax: +65-6861 8402
V7055161 0805
Repl. 1204

You might also like