Item
BOM
Technical Specification
DC Capacity
Module Capacity
Inverter Output Power
Solar Modules-Crystalline
16 Channel String Combiner Boxes and terminal lugs for 4 Outdoor installation, UV resistant, glass fibre reinfiorsed plastic,
Sq.mm solar cable
self extinguishing, halogen free, IP-55 or Higher (IEC 60529),
Voltage grade 650V with earthing stud with self locking door
handle, for mounting on rail or cage clamp type suitable for
conductor sizes 2.5,4,6,10,16,32,64,100,120,240 mm cable inlet
and outlet as per requirement. Facility for providing fuses for
individual circuites, surge arresters & blocking diodes as required
7
(i)
(ii)
(iii)
Make
Unit
Quantity
Canadian Solar/CNPV
Watt
Watt
Watt
Nos.
11000000
300
750000
36666
TMEIC
Nos.
14
Custom Made
MW
11.0
Trinity/Hensel/Statcon or eq.
Nos.
116
Lapp/Reputed or eq.
Nos.
1924
Advance Cables/KEI/Polycab or eq
Mtrs
154000
Havelles/Advance/RPG/Polycab or eq.
Mtrs
24200
Havelles/Advance/RPG/Polycab or eq.
Mtrs
3360
SL. No
1
Item
Technical Specification
i) .380/.380/33 KV
800/800/1600 kVA ONAN, Dy11y11 Off -Load T/C, Z = 5 %, 3 Phase 50 Hz class A
insulation, outdoor type for 50C ambient complete with bushings and cable
boxes, with cable terminations on both LT side and bare bushing on HT side.
ii).380/33 kV
800 kVA ONAN, Off -Load T/C, with cable terminations on LT side and
bare bushing on HT side.
ii) .380/33 KV
800 kVA ONAN, Dy11 Off -Load T/C, Z = 5 %, 3 Phase 50 Hz class A insulation,
outdoor type for 50C ambient complete with bushings and cable boxes, with
cable terminations on both LT side and bare bushing on HT side.
For 33kV outgoing feeders, complete with Outdoor circuit breakers, CT-PT set,
indication meters for current, voltage, power factor and energy, with outdoor C&R
panel with protection relays for grid and internal faults, fully wired with
annunciation and DC fail protection associated auxiliary contects and open close
switches with earthing facility, having annunciation windows and hooter facility.
The system will be controlled from the main control room where all the data from
different parts of the plant will be received, analyzed and action taken either
manually or on auto as per the system design.The scada should have remote
monitoring capability.
LT Power Cable will be 1.1 kV, Armoured, unearthed grade, double core/multi-core,
stranded Cu/Al conductor as mentioned, XLPE insulated with PVC outer sheath
made on PVC compound. All other details will be as Indian Standards .IEC 60189:
IS 694/ IS 1554/IS/IEC 69948
Earthed grade, XLPE, Armoured ,Aluminium, 3 core, PVC outer sheath, self
extinguishing type
Make
Unit
Essennar/Voltamp/Tesla or eq.
Nos.
Quantity
Swastik/Uttam
Nos.
ABB/Schneider/Their approved
System house
Nos.
Standard
Nos.
L&T/SKYTRON/Inaccess or Eq.
MW
11
D-Link/Spiktel
Mtrs
3300
eq.
eq.
eq.
eq.
eq.
Mtrs
2200
1100
1400
1750
1100
Standard
Havelles/Polycab/RPG or eq.
Mtrs
Mtrs
700
1400
Havelles/Polycab/RPG
Havelles/Polycab/RPG
Havelles/Polycab/RPG
Havelles/Polycab/RPG
Havelles/Polycab/RPG
or
or
or
or
or
Custom Made
MW
11
7
8
Custom Made
Custom Made
Set
Nos.
1
7
Nos.
MW
10
11
MW
LS
LS
LS
11
1
1
1
Raychem/3M
Nos.
Standard
LS
MW
1
11
9
10
11
(i)
(ii)
(iii)
(iv)
12
Custom Made
Custom Made
Custom Made
Standard
SL. No
1
(i)
(ii)
(iii)
(iv)
(v)
(vi)
(vii)
2
3
(a)
(b)
4
5
Note:
Item
Foundations and complete Civil Works for :Main Transformers
Structure Foundation for LA and Isolator
VCB Panels
C&R Panel
Four Pole Structure
Auxiliary Transformer
Metering Cubical Foundation
Mod. Mounting Structures Foundation
Cable Trenches (Included In AC/DC Work)
For HT Cable
For LT Cable
Inverter Room CFL, Micro filter, Duct outlet for
hot air , switches, PVC conduit and necessary
wiring from auxiliary supply point for local
lighting etc
Unit
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
MW
Mtrs
Mtrs
Nos.
nt water logging.
Quantity
7
7
7
7
1
1
1
11
1400
8800
4