You are on page 1of 6

Sri Gurikar & Associates, Bangalore

Client
Project name
Title

Designed by checked by
RSS
Date
Rev.No
Slab No.

A. DIMENSIONS OF SLAB:
1. Length of the slab, L
2. Width of the slab, B

=
=

7.7
5

Length to width ratio, L/B

1.54

mtr
mtr

since length to width ratio is less than 2, slab should be designed as two way slab
B. OVER ALL THICKNESS OF THE SLAB:
Span to over all thickness of the slab, r

40

Modification factor for tension reinforcement, m f


( From fig.4, pag 38 of IS:456-2000 )

Over all depth of the slab, D


(D=L /(mfx0.8xr )

156.25

mm

Provided over all depth of the slab

125.00

mm

Clear Cover to the tension reinforcement at bottom

25.00

mm

Assumed diameter of tension reinforcement at bottom

10.00

mm

Effective depth of the slab for design

95.00

mm

Self Weight of the slab

3.13

KN/m2

Dead weight of ceiling plaster, 20 mm thk

0.42

KN/m2

Dead weight of partesion walls

1.50

KN/m2

Dead weight of cement morter over floor,


25 mm thk

0.525

C. LOAD CALCULATION

KN/m2

Dead weight of floor finish

KN/m2

Live load on the slab

3.00

KN/m2

TOTAL LOAD ON THE SLAB FOR DESIGN

10.57

KN/m2

Sri Gurikar & Associates, Bangalore


Client
Project name
Title

Designed by checked by
RSS
Date
Rev.No
Slab No.

A. DIMENSIONS OF SLAB:
1. Length of the slab, L
2. Width of the slab, B

=
=

5
2

Length to width ratio, L/B

2.50

mtr
mtr

since the length to width ratio is more than 2 ,slab should be designed as one way
slab
B. OVER ALL THICKNESS OF THE SLAB:
Span to over all thickness of the slab, r

40

Modification factor for tension reinforcement, m f


( From fig.4, pag 38 of IS:456-2000 )

Over all depth of the slab, D


(D=L /(mfx0.8xr )

62.50

mm

Provided over all depth of the slab

150.00

mm

Clear Cover to the tension reinforcement at bottom

25.00

mm

Assumed diameter of tension reinforcement at bottom

10.00

mm

Effective depth of the slab for design

120.00

mm

C. CALCULATION OF BENDING MOMENTS:


Un factored design load on slab considered
Bending moment Coefficients:
Short span coefficients

KN/m2

(+) ve ay (-) ve ay
0.024
0.028
0.028
0.035
0.035
0.035
0.043
0.043
0.056

Sri Gurikar & Associates, Bangalore


Client
Project name
Title

Designed by checked by
RSS
Date
Rev.No
Slab No.

A. DIMENSIONS OF SLAB:
Short span length, Lx

5 m

Long span length, Ly

6 m

ratio Ly/Lx

1.200 m

since length to width ratio is less than 2, slab should be designed as two way slab
B. OVER ALL THICKNESS OF THE SLAB:
Span to over all thickness ratio of the slab, r

40

Modification factor for tension reinforcement, m f

1.00

Over all depth of the slab, D


(D=L /(mfx0.8xr )

156.3

Provided over all depth of the slab

150.0

Self Weight of the slab

3.750 KN/m2

Dead weight of ceiling plaster, 20 mm thk

0.420 KN/m2

Dead weight of partesion walls

1.00 KN/m2

0.525 KN/m2

Dead weight of floor finish

1.00 KN/m2

Live load on the slab

5.00 KN/m2

Total load

11.70 KN/m2

Considered load for Design (Un factered)

12.5 KN/m2

20 N/mm2

( From fig.4, pag 38 of IS:456-2000 )

C. LOAD CALCULATION

Dead weight of cement morter over floor,


mm thk

25

D. DESIGN CONSTANTS
Characteristic strength of concrete, f ck

Characteristic strength of steel, f y

Assumed over all depth of slab, D

150.0 mm

Effective cover to tension reinforcement, d'

25 mm

Effective depth of slab, d

125 mm

415 N/mm2

Slab end condition :


1

***

Short span
coefficients

Long span
coefficients
(y)

(+) Ve coffet at mid span

0.036

0.028

(-) Ve coffet at continuous edge

0.048

0.037

Number of dis continuous edges

E. MOMENT COEFFICIENTS

F. MOMENT CALCULATION
Mx (+)ve

11.295 KN-m

Mx (-)ve

15.061 KN-m

My (+)ve

8.59 KN-m

My (-)ve

11.458 KN-m

Effective depth required, d

90.47 mm

Ast(X+v)ve

402.28 mm2

Ast(X-v)ve

550.95 mm2

Ast(Y+v)ve

300.63 mm2

Ast(Y-v)ve

408.54 mm2

Adopted bar dia for +ve moment


Adopted bar dia for -ve moment

=
=

safe

Spacing (X +ve)
Spacing (X -ve)
Spacing (Y +ve)
Spacing (y -ve)

8 mm
8 mm
124.95
91.23
167.20
123.04

mm
mm
mm
mm

You might also like