You are on page 1of 114

Railway Cables

Introduction
Railway Cables

Plant Kapfenberg-Eind

Pengg Kabel GmbH is an Austrian cable manufacturer and a member of the german Wilms group with two plants in Styria. We have
two sites, one in Kapfenberg where we produce copper cables and
the second in Wartberg where we are specialised on fiber optic
cables and components. At the location in Kapfenberg-Eind we
have been producing railway cables for more than 40 years.
In order to ensure the quality of our products and services and to
improve continuously the processes, we have already in the midnineties set up a quality management system according to EN ISO
9001 which is certified by an accredited body.
With our production equipment we are able to produce all usual
kinds of stranding such as layer-stranding, SZ-stranding and random stranding. On this basis, we are able to produce the main types
of railway and telecommunication cables.
Telecommunication cables:
conductor diameter 0,4 mm up to 1,8 mm
symmetric local and district cables
symmetric indoor cables
all types of jumper wires according to national and international
standards and/or customers specifications.
Differential protection cables:
conductor diameter 0,4 mm and 1,8 mm
Cables for watersupply- as well as for power-supply companies:
with pairs, triples or quads
special filling materials
different kinds of electrical shielding
Control cables for railway applications, special cables:
with plastic insulation
with cores, pairs or quads
spare cables in plastic version for paper-lead cables
Flexibility and customer proximity are the bases for a successful
development on the market. New developments and product improvements are always necessary. Apart of the permanent search for
improvements of our products, our efforts for the future run towards
reduction of production time, increase of flexibility and constant
improvement of quality, in order to be a reliable partner for our customers.

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Contact Persons
Railway Cables
Managing Director:

Area representatives:

Max Rothwangl
Managing Director

PROCABLE S.A.
Isabelle & Udo Guldner

+352 (0)263 40244

+352 (0)263 40245


procable@pt.lu

(+43) (0)3862 23990 410

Area representative in France and

(+43) (0)3862 23990 452

Luxembourg

max.rothwangl@penggkabel.at

7, Z.I. Bombicht

URL: www.procable.lu

L-6947 Niederanven

Product Development Manager:


Werner Lenger
Product Development Manager - Railway Cables

Luxembourg
Interteam Srl
Mauro Rota

+39 0345 90938

(+43) (0)3862 23990 418

Area representative in Italy

+39 0345 50684

(+43) (0)3862 23990 444

Via C. Battisti, 50

rota.mauro@inter-team.it

werner.lenger@penggkabel.at

I-24019 Zogno (BG)

URL: www.inter-team.it

Italy

Sales Director:
Uwe Lcker
Key Account Manager
(B, BG, BY, CH, CY, DK, E, EST, FIN, GR, H, I, IRL, L, LT, LV,
N, P, RO, S)

+971 (0)503508277

Area representative in UAE

+971 (4)4434698

HQ Building A109/1

swl501@gmail.com

Spyros Sakelliou

+30 (0)210 8322611612

Area representative in Greece

+30 (0)210 8325444

15B, Konstantinidou Str.

sasta@otenet.gr

Guy Colman

+32 (0)32532350

Area representative in Belgium

+32 (0)32532351

Laagstraat 65

guy.colman@cynerpro.be

URL: www.cynerpro.be

(+43) (0)3862 23990 690

(+43) (0)3862 23990 672

Silicon Oasis, Dubai

uwe.loecker@penggkabel.at

UAE
Sasta/Sakelliou Spyros & CO OE

Key Accounts:
Robert Hofreiter
Key Account Manager
(A, AL, BIH, HR, KOS, MK, MNE, SLO, SRB)

(+43) (0)3862 23990 683

(+43) (0)3862 23990 672

robert.hofreiter@penggkabel.at

Holger Quest
Key Account Manager
(D)

GR-104 45 K.Patissia, Athen


Greece
CYNERPRO NV/SA

(+49) (0)172 95 99 471

(+43) (0)3862 23990 672

B-9140 Temse

holger.quest@penggkabel.at

Belgium

Gerd Pichler
Key Account Manager
(I, NL, D)

Dr. Giorgio Cumbat


+49 (0)956128518

Area representative in Italy

(+43) (0)3862 23990 441

Am Flecken 24

+49 (0)1728141232

(+43) (0)3862 23990 672

D-96450 Coburg

giorgio.cumbat@

gerd.pichler@penggkabel.at

Germany

Cableteam FZE
Stefan Leicht

t-online.de

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Index

Austrian Railways (BB)

from page 7

German Railways (DB)

from page 17

French Railways (SNCF)

from page 57

Swiss Railways (SBB)

from page 65

Hungarian Railways (MAV)

from page 69

Slovenian Railways (SZ)

from page 73

Fiber Optic Cables

from page 75

General Information

from page 97

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Railway Cables
Note

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

S-X2YA2YB2Y 1x4x1,53 HD

page 8

S-X2YA2YB11Y 1x4x1,8 K35

page 9

S-2Y2YBY ..x4x..

page 10

S-2Y2YCB2Y ..x4x.. (J0...) HD

page 11

S-2Y2YCB2Y ..x.. RE (J0...) HD

page 12

S-2Y2YBY ..x.. RE

page 13

S-2YY ..x..

page 14

F-2Y2YC2Y ..x2x0,8

page 15

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways
(BB)

Austrian Railways, BB

Austrian Railways
PE insulated, star-quad, with inductive protection

S-X2YA2YB2Y 1x4x1,53 HD
C42

mutual capacity

filling

cable elements

overall shield,
armouring

number of
double cores

S-X2YA2YB2Y 1x4x1,53 HD

Construction
Conductor:

solid, bare copper wire 1,53 mm

Insulation:

PE (2Y)

Colour code:

a core : transparent
b core : transparent
c core : RD
d core : RD

Cable make up:

cores twisted to a quad, wrapping with tape

Screening:

copper wire netting, tinned (9x0,10mm); aluminium


shield (A)

Sheath:

PE, black (2Y)

Armouring:

one layer steel tape (B)

Protective cover:

HDPE, grey (2Y)

Cable short mark:

outer diameter
approx. mm

Application
The cable is designed for the connection of ETCS-Balisen.

special design (X)


protective PE cover with high density (HD)

number of
double cores

dimension of
conductor

1,53

Type

15,0

weight
approx. kg/km

292,8

Technical Details (at 20C)


Standard:

Customer information

Conductor diameter:

1,53

mm

Loop resistance:

19,8

/km

Insulation resistance:

10

Gkm

Mutual capacitance (at f=800Hz): 42

nF/km

Attenuation:
1,8 MHz

1,0

dB/100m

120+/-20

K1

400

pF/km

ea1/2

650

pF/km

conductor/conductor

2000

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

during operation

-30 to +60

during installation

-20 to +50

Impedance:
1,8 MHz
Capacitance unbalance:

Dielectric strength:

Temperature range:

Marking
type - LEU - SIGNAL (4 x) - PENGG KABEL - <meter> - order number

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways

Type

mutual capacity

#
1,83

dimension of
conductor

filling

cable elements

overall shield,
armouring

Construction
Conductor:

strand, bare copper wire 1,83 mm

Insulation:

PE (2Y)

Colour code:

a core : transparent
b core : transparent
c core : RD
d core : RD

Cable make up:

cores twisted to a quad, wrapping with tape

Screening:

copper wire netting, tinned (11x0,10 mm); aluminium


shield (A)

Sheath:

PE, black (2Y)

Armouring:

one layer steel tape (B)

Protective cover:

Polyurethan Elastollan, black (11Y)


special design (X)
operation termperatur till -35 C (K35)

outer diameter
approx. mm

Application
The cable is designed for the connection of ETCS-Balisen.

number of
double cores

C45

number of
double cores

S-X2YA2YB11Y 1x4x1,8 (0,35) K35

Cable short mark:

S-X2YA2YB11Y 1x4x1,8 K35

19,9

Austrian Railways
(BB)

PE insulated, star-quad, with inductive protection

weight
approx. kg/km

450,4

Technical Details (at 20C)


Standard:

Customer information

Conductor cross section:

1,83

mm

Loop resistance:

19,8

/km

Insulation resistance:

Gkm

Mutual capacitance (at f=800Hz): 42

nF/km

Attenuation:
1,8 MHz

1,0

dB/100m

120+/-20

k1

400

pF/km

ea1/2

650

pF/km

conductor/conductor

2000

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

during operation

-35 to +60

during installation

-20 to +50

Impedance:
1,8 MHz
Capacitance unbalance:

Dielectric strength:

Temperature range:

Marking
type - LEU - SIGNAL (4 x) - PENGG KABEL - <meter> - order number

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways
PE insulated, star-quads, with rodent protection

S-2Y2YBY ..x4x..
C42

0,8

mutual capacity

0,9

number of
double cores

2-100

dimension of
conductor

1,4

filling

overall shield,
armouring

cable elements

Type

S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY

1x4x...
2x4x...
3x4x...
5x4x...
7x4x...
10x4x...
15x4x...
20x4x...
25x4x...

conductor diameter 0.8 mm

conductor diameter 0.9 mm

conductor diameter 1.4 mm

number of
double cores

outer diameter
approx. mm

weight
approx. kg/km

outer diameter
approx. mm

weight
approx. kg/km

outer diameter
approx. mm

weight
approx. kg/km

2
4
6
10
14
20
30
40
50

11,6
15,6
16,3
18,7
20,0
25,2
28,5
29,8
35,4

186,7
303,0
326,0
432,4
503,8
714,4
932,2
1040,1
1379,2

12,3
17,8
18,7
20,5
22,0
28,0
31,6
33,1
39,9

208,2
363,3
392,7
511,1
600,4
822,7
1125,0
1326,3
1706,8

15,5
23,4
24,6
29,2
31,6
40,5
47,1
49,4
60,0

236,6
612,8
721,4
977,2
1181,6
1684,7
2371,1
2843,9
3770,0

Application
The cable is desigend for use in railway protection systems.
Construction
Conductor:

solid, bare copper wire 0,8 / 0,9 / 1,4 mm

Insulation:

PE (2Y)

Colour code:

beginning quad

other quads

BK

transparent

b core:

RD

RD

c core:

GN

GN

d core:

BU

BU

a core:

Cable make up:

cores twisted to quads, quads stranded together in


concentric layers, wrapping with tape

Sheath:

PE, black (2Y)

Armouring:

one or two layers steel tape (B), wrapping of tape

Protective cover:

PCV, grey (2Y)

Technical Details (at 20C)


Standard:

VE- K 11 / 4 06.95

Conductor diameter:

0,8

0,9

1,4

Loop resistance:

72,3

56,6

23,4 /km

Insulation resistance:

10

mm
Gkm

Mutual capacitance (at f=800Hz):


100%

42

nF/km

95%

40

nF/km

75%

38

nF/km

Capacitance unbalance:
100%

800

pF/300m

95%

400

pF/300m

K9-12

300

pF/300m

ea1/2

650

pF/300m

pF/425m

K1

K1

Marking
PENGG KABEL - type- BB sign - <meter> ; SIGNAL fills the free space for
gaps, less then 10 cm

100%

185

185

(6 quads) -

70

70

pF/425m

K9-12

170

170

pF/425m

ea1/2

550

550

pF/425m

Dielectric strength:
conductor/conductor

2500

V/50Hz/2min

conductor/shield

2500

V/50Hz/2min

250

Veff

during operation

-30 to +60

during installation

-20 to +50

Operating voltage:
Temperature range:

10

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways
S-2Y2YCB2Y x4x (J) HD
C42

0.9

mutual capacity

1.4

2-100

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y

number of
double cores

1x4x...
2x4x...
3x4x...
5x4x...
7x4x...
10x4x...
15x4x...
20x4x...
25x4x...

conductor diameter 0.9 mm

conductor diameter 1.4. mm

outer diameter
approx. mm

outer diameter
approx. mm

2
4
6
10
14
20
30
40
50

16,1
22,0
21,5
25,5
27,0
32,2
36,2
37,5
44,9

Application
The cable is desigend for use in railway protection systems.
Construction
Conductor:
Insulation:
Colour code:

Cable make up:

weight
approx. kg/km

solid, bare copper wire 0,9 / 1,4 mm


PE (2Y)
beginning quad
other quads
a core:
BK
transparent
b core:

RD

RD

c core:

GN

GN

d core:

BU

BU

441
670
711
946
1026
1349
1659
1918
2459

PE, black (2Y)

Screening:

one layer copper wire 0,8 mm (C), wrapping of tape

Armouring:

two layers steel tape (B), wrapping of tape

Protective cover:

HDPE, grey (2Y)

Cable short mark:

caracteristic number of reduction factor: (J0,65)


protective PE cover with high density (HD)

Marking
PENGG KABEL - type- BB sign - <meter> ; SIGNAL fills the free space for
gaps, less then 10 cm

19,3
27,2
28,8
33,0
36,0
46,5
52,3
54,4
65,2

weight
approx. kg/km

629
1012
1141
1455
1743
2869
3611
4149
5007

Technical Details (at 20C)


Standard:

VE- K 11 / 4 06.95

Conductor diameter:

0,9

1,4

mm

Loop resistance:

56,6

23,4

/km

Insulation resistance:

10

Gkm

100%

42

nF/km

95%

40

nF/km

75%

38

nF/km

100%

185

Mutual capacitance (at f=800Hz):

Capacitance unbalance:
K1

cores twisted to quads, quads stranded together in


concentric layers, wrapping with tape

Sheath:

number of
double cores

Austrian Railways
(BB)

PE insulated, star-quad, with inductive protection

185

pF/425m

(6 quads) 70

70

pF/425m

K9-12

170

170

pF/425m

ea1/2

550

550

pF/425m

Dielectric strength:
conductor/conductor

2500

2500

V/50Hz/2min

conductor/shield

2500

2500

V/50Hz/2min

250

250

Veff

Operating voltage:
Temperature range:
during operation

-30 to +60

during installation

-20 to +50

Reduction factor:

according to VE-K11/ 4. 6.95

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

11

Austrian Railways
PE insulated, single core, with inductive protection

S-2Y2YCB2Y ..x.. RE (J) HD


mutual capacity

#
1,5

#
2,5

#
4,0

5-80

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY

number of
cores

5x...
10x...
15x...
20x...
30x...
60x...
80x...

5
10
15
20
30
60
80

cross section 1,5 mm

cross section 2,5 mm

cross section 4mm

outer diameter
approx. mm

outer diameter
approx. mm

outer diameter
approx. mm

weight
approx. kg/km

17,7
21,0
23,6
25,2
28,1
35,8
40,5

Application
The cable is designed for use in railway protection systems, for underground
laying and drawing into conduits.
The cross section of this cable type goes from 0,75 to 25 mm.
Construction
Conductor:
Insulation:
Colour code:

solid, bare copper wire


PE (2Y)
tracer core in each layer: blue
other cores: transparent

Cable make up:

number of
cores

cores cabeld together in concentric layers, wrapping


of tape

576
745
929
1067
1339
2144
3028

weight
approx. kg/km

19,3
24,2
26,5
28,4
32,1
42,2
48,1

679
978
1195
1406
1804
3429
4286

weight
approx. kg/km

21,6
24,3
30,2
32,7
37,6
50,3
57,4

770
1190
1572
1827
2445
4889
6219

Technical Details (at 20C)


Standard:

VE- K 10 / 10 06.95

Conductor cross section:

1,5

2,5

4,0

mm

Conductor resistance:

12,1

7,28

4,56

/km

Insulation resistance:

Mutual capacitance:

120

120

120

nF/km

Gkm

Dielectric strength:
conductor/conductor

3500

3500

3500

V/50Hz/2min

conductor/shield

3500

3500

3500

V/50Hz/2min

800

800

800

Veff

Operating voltage:
Temperature range:

Sheath:

PE, black (2Y)

during operation

-30 to +60

Screening:

one layer copper wire 0,8 mm (C), wrapping of tape

during installation

-5 to +50

Armouring:

two layers steel tape (B), wrapping of tape

Protective cover:

HDPE, grey (2Y)

Cable short mark:

circular (R)

Reduction factor:

according to VE-K10/10 06.95

single core (E)


caracteristic number of redution factor: (J0,65)
protective PE cover with high density (HD)
Marking
PENGG KABEL - type- BB sign - <meter> ; SIGNAL fills the free space for
gaps, less then 10 cm

12

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways
S-2Y2YBY ..x.. RE
mutual capacity

#
0,75

#
1,5

5-100

dimension of
conductor

#
2,5

S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY

number of
cores

5x...
10x...
15x...
20x...
30x...
60x...
80x...
100x...

5
10
15
20
30
60
80
100

overall shield,
armouring

cross section 0.75 mm

cross section 1,5 mm

cross section 2.5 mm

outer diameter
approx. mm

outer diameter
approx. mm

outer diameter
approx. mm

weight
approx. kg/km

12,5
15,0
16,4
17,4
19,8
25,6
28,8
32,0

Application
The cable is designed for use in railway protection systems, for underground
laying and drawing into conduits.
The cross section of this cable type goes from 0,75 to 25 mm.

228
316
392
463
596
1024
1281
1532

293
434
562
684
895
1605
2086
2530

weight
approx. kg/km

15,5
19,6
21,9
24,6
28,3
37,2
42,1
48,2

373
592
767
996
1341
2403
3076
3858

Technical Details (at 20C)


Standard:

VE- K 10 / 10 06.95

Conductor cross section:

0,75

1,5

2,5

mm

Conductor resistance:

24,5

12,1

7,28

/km

100

120

Insulation resistance:
solid, bare copper wire

Mutual capacitance:

Insulation:

PE (2Y)

Dielectric strength:

Cable make up:

weight
approx. kg/km

14,1
17,4
19,2
20,8
23,7
31,2
35,7
40,0

Construction
Conductor:
Colour code:

number of
cores

filling

cable elements

Type

Austrian Railways
(BB)

PE insulated, star-quad, with inductive protection

Gkm

5
120

nF/km

tracer core in each layer: blue

conductor/conductor

2500

3500

3500

V/50Hz/2min

other cores: transparent

conductor/shield

2500

3500

3500

V/50Hz/2min

400

800

800

Veff

cores cabeld together in concentric layers, wrapping


of tape

Operating voltage:
Temperature range:

Sheath:

PE, black (2Y)

during operation

-30 to +60

Armouring:

one layer steel tape (B)

during installation

-5 to +50

Protective cover:

PVC, grey (Y)

Cable short mark:

circular (R)
single core (E)

Marking
PENGG KABEL - type- BB sign - <meter> ; SIGNAL fills the free space for
gaps, less then 10 cm

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

13

Austrian Railways
PE insulated, single core

S-2YY ..x..
mutual capacity

#
0,75

#
1,5

#
2,5

5-100

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

S-2YY
S-2YY
S-2YY
S-2YY
S-2YY

number of
double cores

10x1,5
10x2,5
19x0,75
19x1,5
19x2,5

VE- K 10 / 10 06.95

Conductor cross section:

0,75

1,5

2,5

mm

Conductor resistance:

24,5

12,1

7,28

/km

120

120

Insulation resistance:

Mutual capacitance:

100

Insulation:

PE (2Y)

Dielectric strength:

Sheath:

287
418
289
468
730

Technical Details (at 20C)


Standard:

solid, bare copper wire

Cable make up:

weight
approx. kg/km

14,4
16,8
14,0
17,0
21,0

Construction
Conductor:
Colour code:

Gkm
nF/km

tracer core in each layer: blue

conductor/conductor

2500

3500

3500

V/50Hz/2min

other cores: transparent

conductor/shield

2500

3500

3500

V/50Hz/2min

400

800

800

Veff

cores cabeld together in concentric layers, wrapping


of tape
PVC, grey (Y)

Marking
PENGG KABEL - type- BB sign - <meter> ; SIGNAL fills the free space for
gaps, less then 10 cm

14

outer diameter
approx. mm

10
10
19
19
19

Application
The cable is designed for use in railway protection systems, for underground
laying and drawing into conduits.
The cross section of this cable type goes from 0,75 to 25 mm.

number of
cores

Operating voltage:
Temperature range:
during operation

-30 to +60

during installation

-5 to +50

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Austrian Railways
F-2Y2YC2Y ..x2x0,8
C55

0.8

Type

F-2Y2YC2Y
F-2Y2YC2Y
F-2Y2YC2Y
F-2Y2YC2Y

mutual capacity

filling

cable elements

overall shield,
armouring

outer diameter
approx. mm

6
14
20
40

Application
The cable is desigend as speaker cable for railway telecommunication.
Construction

number of
double cores

dimension of
conductor

number of
double cores

6x2x0,8
14x2x0,8
20x2x0,8
40x2x0,8

6-40

14
17
20
23

weight
approx. kg/km

210
340
440
730

Technical Details (at 20C)


Standard:

TL BB 002 / E-11.84 + Nt. 12.06

Conductor diameter:

0,8

mm

Loop resistance:

72,3

/km

Conductor:

solid, bare copper wire 0,8 mm

Screen resistance:

Insulation:

PE (2Y)

20

Insulation resistance:

10

Gkm

55

nF/km

Colour code:

beginning quad

other quads

Mutual capacitance (at f=800Hz):

BK

transparent

Capacitance unbalance:

b core:

RD

RD

c core:

GN

GN

d core:

BU

BU

a core:

Cable make up:

cores twisted to quads, quads stranded together to the


cable core, wrapping with tape

Sheath:

PE, black (2Y)

Screening:

one layer copper tape (C)

Protective cover:

PE, black (2Y)

Austrian Railways
(BB)

PE insulated, star-quad, with copper screening

100%

800

pF/300m

95%

400

pF/300m

K9-12

300

pF/300m

ea1/2

800

pF/300m

conductor/conductor

2500

V/50Hz/2min

conductor/shield

2500

V/50Hz/2min

K1

Dielectric strength:

Marking
order number - type - BB sign - <meter> - PENGG KABEL - month and year
of production - handset symbol

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

15

Austrian Railways
Note

16

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

A-2YOF(L)2YB2Y ..x1x.. S (H115/H145)

page 19

AJ-2YOF(L)2YDB2Y ..x1x0,9 S (H115)

page 20

AJ-2YOF(L)2YDB2Y ..x1x1,4 S (H145)

page 21

AJ-2YOF(L)2YDB2Y ..x1x1,8 S (H145)

page 22

A-2YOF(L)2YB2Y ..x1x.. S (H95)

page 23

AJ-2YOF(L)2YDB2Y ..x1x1,4 S (H95)

page 24

AJ-2YOF(L)2YDB2Y ..x1x1,8 S (H95)

page 25

A-2Y2YV ..x1x.. S (H115/H145)

page 26

A-2Y2YB2Y ..x1x.. S (H115/H145)

page 27

AJ-2Y2YDB2Y ..x1x0,9 S (H115)

page 28

AJ-2Y2YDB2Y ..x1x1,4 S (H145)

page 29

AJ-2Y2YDB2Y ..x1x1,8 S (H145)

page 30

A-2Y2YV ..x1x.. S (H95)

page 31

A-2Y2YB2Y ..x1x.. S (H95)

page 32

AJ-2Y2YDB2Y ..x1x1,4 S (H95)

page 33

AJ-2Y2YDB2Y ..x1x1,8 S (H95)

page 34

A-2Y(L)2YV ..x4x.. S (H45)

page 35

A-2Y(L)2YB2Y ..x4x.. S (H45)

page 36

AJ-2Y(L)2YDB2Y ..x4x0,9 S (H45)

page 37

AJ-2Y(L)2YDB2Y ..x4x1,4 S (H45)

page 38

A-02YSTF(L)2YV ..x4x0,9 STI TNP 02

page 39

A-02YSTF(L)2YV ..x4x1,4 / ..x4x0,9 STI A TNP 02

page 40

A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP 02

page 41

A-02YSTF(L)2Y(SR)2Y 5x4x0,9 STI TNP 02

page 42

AJ-02YSTF(L)2YDB2Y ..x4x0,9 STI A TNP 02

page 43

AJ-02YSTF(L)2YDB2Y ..x4x1,4 / ..x4x0,9 STI A TNP 02

page 44

A-02YS(L)2YV ..x4x0,7 mm STI TNP 03

page 45

A-02YS(L)2YB2Y ..x4x0,7 mm STI TNP 03

page 46

A-02YS(L)2Y(SR)2Y ..x4x0,7 mm STI TNP 03

page 47

A-02YS2Y(ST)(ZN)2Y ..x4x0,9 STI TNP 04

page 48

A-02YSF(L)2YV 2x4x1,4 / 2x4x0,9 STI TNP 06

page 49

A-02YSF(L)2Y(SR)2Y 3x4x0,9mm STI TNP 06

page 50

A-2Y(L)2YB2Y 1x4x

page 51

AJ-2Y(L)2YDB2Y 1x4x1,53

page 52
Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
(DB)

German Railways, DB

17

German Railways, DB

18

A-2YF(L)2Y ..x4x0,4 STIII BD

page 53

A-02YSF(L)2Y ..x2x.. STIII BD

page 54

AJ-02YSF(L)2YDB2Y ..x2x0,8 STIII BD

page 55

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-2YOF(L)2YB2Y ..x1x.. S (H115/H145)
2-200

0,9

1,4

1,8

dimension of
conductor

OF

cable elements

Type

A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y

number of
cores

2x1x.. S
4x1x.. S
7x1x.. S
10x1x.. S
14x1x.. S
20x1x.. S
24x1x.. S
30x1x.. S
40x1x.. S
50x1x.. S
60x1x.. S
80x1x.. S
100x1x.. S
120x1x.. S
140x1x.. S
160x1x.. S
180x1x.. S
200x1x.. S

number of cores

filling

overall shield,
armouring

conductor diameter 0.9 mm

conductor diameter 1.4 mm

conductor diameter 1.8 mm

outer diameter
approx. mm

outer diameter
approx mm

outer diameter
approx. mm

2
4
7
10
14
20
24
30
40
50
60
80
100
120
140
160
180
200

13,0
13,0
14,0
17,0
17,0
18,0
20,0
20,0
21,0
23,0
25,0
26,0
31,0
32,0
35,0
36,0
39,0
39,0

weight
approx. kg/km

160
170
220
290
300
380
460
490
590
700
800
1000
1250
1390
1650
1790
2030
2150

14,0
17,0
18,0
19,0
22,0
23,0
24,0
27,0
29,0
32,0
35,0
39,0
41,0
44,0
46,0
49,0
50,0

weight
approx. kg/km

240
320
410
490
630
730
840
1050
1280
1490
1920
2350
2730
3140
3540
3970
4310

16,0
19,0
21,0
22,0
25,0
27,0
29,0
32,0
36,0
38,0
42,0
47,0
49,0
53,0
55,0
59,0
60,0

weight
approx. kg/km

300
430
560
680
890
1060
1230
1560
1940
2280
2920
3630
4230
4890
5490
6160
6710

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0113

Conductor diameter:

0,9

1,4

1,8

mm

Loop resistance:

28,9

11,9

7,2

/km

Insulation resistance:

1,5

1,5

1,5

Gkm

Mutual capacitance (at f=800Hz): 115

145

145

nF/km

Construction
Conductor:

solid, bare copper wire 0,9 / 1,4 / 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent

Cable make up:

cores cabled together in concentric layers

Filling:

low capacity filling (OF), (longitudinal watertight)

Laminated sheath:

aluminium laminated PE-sheath ((L)2Y), black (transverse watertight)

Armouring:

1 layer galvanized steel tape (0,3 mm) (B) for rodent


protection

Protective cover:

PE (2Y), black

Design:

2 up to 200 cores ( 0,9)

(H115)

(H145)

(H145)

600

600

600

V/DC

420

420

420

Veff/100Hz

Dielectric strength (cond./cond.): 2500

2500

2500

V/AC/1min

Dielectric strength (cond./shield): 2500

2500

2500

V/AC/1min

Operating voltage:

German Railways
(DB)

PE-insulated, single core, with rodent protection

Temperature range:
during installation

-10 to +60

during operation

-40 to +60

4 up to 200 cores ( 1,4 / 1,8)


Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

19

German Railways
PE-insulated, single core, with inductive protection

AJ-2YOF(L)2YDB2Y ..x1x0,9 S (H115)

dimension of
conductor

0,9

10200

number of cores

OF

filling

cable elements

Type

number of
cores

AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y

10x1x0,9 S (H115)
20x1x0,9 S (H115)
30x1x0,9 S (H115)
50x1x0,9 S (H115)
80x1x0,9 S (H115)
120x1x0,9 S (H115)
160x1x0,9 S (H115)
200x1x0,9 S (H115)
10x1x0,9 S (H115)
20x1x0,9 S (H115)
30x1x0,9 S (H115)
50x1x0,9 S (H115)
80x1x0,9 S (H115)
120x1x0,9 S (H115)
160x1x0,9 S (H115)
200x1x0,9 S (H115)

10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200

index of inductiveprotection rk (f=16 2/3 Hz)

600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500

overall shield,
armouring

outer diameter
approx. mm

21,0
22,0
24,0
27,0
30,0
35,0
39,0
41,0
21,0
22,0
24,0
27,0
30,0
35,0
39,0
41,0

weight
approx. kg/km

650
750
900
1190
1560
2040
2500
2930
750
870
1040
1320
1740
2230
2720
3160

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0113

Conductor diameter:

0,9

mm

Loop resistance:

28,9

/km

Insulation resistance:

10

Gkm

Mutual capacitance (at f=800Hz): 115

Construction
Conductor:

solid, bare copper wire 0,9 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent

Cable make up:

cores cabled together in concentric layers

Filling:

low capacity filling (OF), (longitudinal watertight)

Laminated sheath::

aluminium laminated PE-sheath ((L)2Y), black (transverse watertight)

Screening:

nF/km

(H115)
Reduction factor:

acc.to DB AG 416.0116

Operating voltage:

600

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

Temperature range:

1 layer copper wires ( 0,9 / 1,2) (D)

during installation

-10 to +60

wrapping of plastic tape

during operation

-40 to +60

Armouring:

2 layer galvanized steel tape (0,5) (B)

Protective cover:

PE (2Y), black

Design:

10 up to 200 cores ( 0,9)

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

20

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
AJ-2YOF(L)2YDB2Y ..x1x1,4 S (H145)

dimension of
conductor

1,4

10200

number of cores

OF

filling

cable elements

Type

number of
cores

AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y

10x1x1,4 S (H145)
20x1x1,4 S (H145)
30x1x1,4 S (H145)
50x1x1,4 S (H145)
80x1x1,4 S (H145)
120x1x1,4 S (H145)
160x1x1,4 S (H145)
200x1x1,4 S (H145)
10x1x1,4 S (H145)
20x1x1,4 S (H145)
30x1x1,4 S (H145)
50x1x1,4 S (H145)
80x1x1,4 S (H145)
120x1x1,4 S (H145)
160x1x1,4 S (H145)
200x1x1,4 S (H145)
50x1x1,4 S (H145)
80x1x1,4 S (H145)
120x1x1,4 S (H145)
160x1x1,4 S (H145)
200x1x1,4 S (H145)

10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
50
80
120
160
200

index of inductiveprotection rk (f=16 2/3 Hz)

600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
400
400
400
400
400

overall shield,
armouring

outer diameter
approx. mm

22,0
26,0
28,0
33,0
38,0
44,0
49,0
53,0
22,0
26,0
28,0
33,0
38,0
45,0
50,0
54,0
36,0
42,0
48,0
53,0
57,0

weight
approx. kg/km

790
1090
1350
1890
2630
3560
4460
5290
920
1230
1490
2080
2850
3880
4790
5650
2770
3770
4870
5880
6830

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0113

Conductor diameter:

1,4

mm

Loop resistance:

11,9

/km

Insulation resistance:

10

Gkm

mutual capacitance (at f=800Hz): 145

Construction
Conductor:

solid, bare copper wire 1,4 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent

nF/km

(H145)
Reduction factor:

acc. to DB AG 416.0116

Operating voltage:

600

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

Cable make up:

cores cabled together in concentric layers

Filling:

low capacity filling (OF), (longitudinal watertight)

Laminated sheath::

aluminium laminated PE-sheath ((L)2Y), black (transverse watertight)

Screening:

1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D)

during installation

-10 to +60

wrapping of plastic tape

during operation

-40 to +60

Armouring:

2 layer galvanized steel tape (0,5 / 0,8) (B)

Protective cover:

PE (2Y), black

Design:

10 up to 200 cores ( 1,4)

German Railways
(DB)

PE-insulated, single core, with inductive protection

Temperature range:

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

20

German Railways
PE-insulated, single core, with inductive protection

AJ-2YOF(L)2YDB2Y ..x1x1,8 S (H145)

dimension of
conductor

1,8

cable elements

Type

number of
cores

AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y

10x1x1,8 S (H145)
20x1x1,8 S (H145)
30x1x1,8 S (H145)
50x1x1,8 S (H145)
80x1x1,8 S (H145)
120x1x1,8 S (H145)
160x1x1,8 S (H145)
200x1x1,8 S (H145)
10x1x1,8 S (H145)
20x1x1,8 S (H145)
30x1x1,8 S (H145)
50x1x1,8 S (H145)
80x1x1,8 S (H145)
120x1x1,8 S (H145)
160x1x1,8 S (H145)
200x1x1,8 S (H145)
30x1x1,8 S (H145)
50x1x1,8 S (H145)
80x1x1,8 S (H145)
120x1x1,8 S (H145)
160x1x1,8 S (H145)
200x1x1,8 S (H145)

10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
30
50
80
120
160
200

index of inductiveprotection rk (f=16 2/3 Hz)

600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
400
400
400
400
400
400

10200

number of cores

OF

filling

overall shield,
armouring

outer diameter
approx. mm

25,0
29,0
33,0
39,0
45,0
52,0
58,0
63,0
25,0
29,0
33,0
39,0
46,0
53,0
59,0
64,0
36,0
43,0
49,0
56,0
62,0
67,0

weight
approx. kg/km

1010
1420
1840
2670
3770
5210
6600
7900
1150
1570
2010
2870
4090
5560
6980
8320
2690
3800
5100
6730
8290
9730

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0113

Conductor diameter:

1,8

mm

Loop resistance:

7,2

/km

Insulation resistance:

10

Gkm

Mutual capacitance (at f=800Hz) 145

Construction
Conductor:

solid, bare copper wire 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent

nF/km

(H145)
Reduction factor:

acc. to DB AG 416.0116

Operating voltage:

60

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

Cable make up:

cores cabled together in concentric layers

Filling:

low capacity filling (OF), (longitudinal watertight)

Laminated sheath::

aluminium laminated PE-sheath ((L)2Y), black (transverse watertight)

Screening:

1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D)

during installation

-10 to +60

wrapping of plastic tape

during operation

-40 to +60

Armouring:

2 layer galvanized steel tape (0,5 / 0,8) (B)

Protective cover:

PE (2Y), black

Design:

10 up to 200 cores ( 0,9)

Temperature range:

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

22

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-2YOF(L)2YB2Y ..x1x.. S (H95)

1,4

1,8

4-80

number of cores

OF

filling

dimension of
conductor

cable elements

Type

number of
cores

A-2YOF(L)2YB2Y 4x1x.. S (H95)


A-2YOF(L)2YB2Y 7x1x.. S (H95)
A-2YOF(L)2YB2Y 10x1x.. S (H95)
A-2YOF(L)2YB2Y 14x1x.. S (H95)
A-2YOF(L)2YB2Y 20x1x.. S (H95)
A-2YOF(L)2YB2Y 24x1x.. S (H95)
A-2YOF(L)2YB2Y 30x1x.. S (H95)
A-2YOF(L)2YB2Y 40x1x.. S (H95)
A-2YOF(L)2YB2Y 50x1x.. S (H95)
A-2YOF(L)2YB2Y 60x1x.. S (H95)
A-2YOF(L)2YB2Y 80x1x.. S (H95)

4
7
10
14
20
24
30
40
50
60
80

overall shield,
armouring

conductor diameter 1.4 mm

conductor diameter 1.8 mm

outer diameter
approx mm

weight
approx. kg/km

outer diameter
approx. mm

weight
approx. kg/km

16,0
18,0
21,0
22,0
25,0
28,0
29,0
33,0
36,0
39,0
43,0

280
370
490
590
750
890
1030
1270
1590
1840
2330

18,0
20,0
25,0
26,0
30,0
34,0
36,0
39,0
43,0
46,0
51,0

360
500
680
830
1090
1300
1530
1910
2360
2780
3570

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0114

Conductor diameter:

1,4

1,8

mm

Loop resistance:

11,9

7,2

/km

Insulation resistance:

10

10

Gkm

Mutual capacitance (at f=800Hz) 95

95

nF/km

600

600

V/DC

420

420

Veff/100Hz

Dielectric strength (cond./cond.) 2500

2500

V/50Hz/1min

Construction
Conductor:

solid, bare copper wire 1,4 / 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent

Cable make up:

cores cabled together in concentric layers

Filling:

low capacity filling (OF), (longitudinal watertight)

Laminated sheath::

aluminium laminated PE-sheath ((L)2Y), black (transverse watertight)

Armouring:

1 layer galvanized steel tape (0,3 mm) (B) for rodent


protection

Protective cover:

PE (2Y), black

Design:

10 up to 20 cores ( 1,4)

German Railways
(DB)

PE-insulated, single core, with rodent protection

(H95)
Operating voltage:

Temperature range:
during installation

-10 to +60

during operation

-40 to +60

10 up to 14 cores ( 1,8)
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

23

German Railways
PE-insulated, single core, with inductive protection

AJ-2YOF(L)2YDB2Y ..x1x1,4 S (H95)

10-50

dimension of
conductor

1,4

OF

cable elements

Type

number of
cores

AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y

10x1x1,4
14x1x1,4
20x1x1,4
30x1x1,4
50x1x1,4
30x1x1,4
50x1x1,4

S
S
S
S
S
S
S

(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)

10
14
20
30
50
30
50

index of inductiveprotection rk (f=16 2/3 Hz)

500
500
500
500
500
400
400

number of cores

filling

overall shield,
armouring

outer diameter
approx. mm

25,0
26,0
29,0
33,0
39,0
37,0
43,0

weight
approx. kg/km

1100
1220
1430
1820
2530
2530
3480

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0114

Conductor diameter:

1,4

mm

Loop resistance:

11,9

/km

Insulation resistance:

10

Gkm

Mutual capacitance (at f=800Hz): 95

nF/km

Construction
Conductor:

solid, bare copper wire 1,4 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent

(H95)
Reduction factor:

acc. to DB AG 416.0116

Operating voltage:

600

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

Cable make up:

cores cabled together in concentric layers

Filling:

low capacity filling (OF), (longitudinal watertight)

Laminated sheath:

aluminium laminated PE-sheath ((L)2Y), black (transverse watertight)

Screening:

1 layer copper wires ( 0,9 / 1,2 / 1,8) (D)

during installation

-10 to +60

wrapping of plastic tape

during operation

-40 to +60

Armouring:

Temperature range:

2 layer galvanized steel tape (0,5 / 0,8) (B)

Protective cover:

PE (2Y), black

Design:

10 up to 50 cores ( 1,8)

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

24

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
AJ-2YOF(L)2YDB2Y ..x1x1,8 S (H95)
10-50

dimension of
conductor

1,8

OF

cable elements

Type

number of
cores

AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y

10x1x1,8
14x1x1,8
20x1x1,8
30x1x1,8
50x1x1,8
30x1x1,8
50x1x1,8

S
S
S
S
S
S
S

(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)

10
14
20
30
50
30
50

index of inductiveprotection rk (f=16 2/3 Hz)

500
500
500
500
500
400
400

number of cores

filling

overall shield,
armouring

outer diameter
approx. mm

29,0
30,0
33,0
39,0
47,0
43,0
50,0

weight
approx. kg/km

1340
1560
1880
2460
3560
3380
4600

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0114

Conductor diameter:

1,8

mm

Loop resistance:

7,2

/km

Insulation resistance:

10

Gkm

Mutual capacitance (at f=800Hz):95

nF/km

Construction
Conductor:

solid, bare copper wire 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent

(H95)
Reduction factor:

acc. to DB AG 416.0116

Operating voltage:

600

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

Cable make up:

cores cabled together in concentric layers

Filling:

low capacity filling (OF), (longitudinal watertight)

Laminated sheath::

aluminium laminated PE-sheath ((L)2Y), black (transverse watertight)

Screening:

1 layer copper wires ( 0,9 / 1,2 / 1,8) (D)

during installation

-10 to +60

wrapping of plastic tape

during operation

-40 to +60

Armouring:

German Railways
(DB)

PE-insulated, single core, with inductive protection

Temperature range:

2 layer galvanized steel tape (0,5 / 0,8) (B)

Protective cover:

PE (2Y), black

Design:

10 up to 50 cores ( 1,8)

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

25

German Railways
PE-insulated, core stranded, with reinforced sheath

A-2Y2YV ..x1x.. S (H115/H145)


2-200

0,9

1,4

1,8

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV

number of
cores

2x1x.. S
4x1x.. S
7x1x.. S
10x1x.. S
14x1x.. S
20x1x.. S
24x1x.. S
30x1x.. S
40x1x.. S
50x1x.. S
60x1x.. S
80x1x.. S
100x1x.. S
120x1x.. S
140x1x.. S
160x1x.. S
180x1x.. S
200x1x.. S

number of cores

conductor diameter 0.9 mm

conductor diameter 1.4 mm

conductor diameter 1.8 mm

outer diameter
approx. mm

outer diameter
approx mm

outer diameter
approx. mm

2
4
7
10
14
20
24
30
40
50
60
80
100
120
140
160
180
200

9,0
9,0
11,0
12,0
13,0
14,0
15,0
16,0
17,0
19,0
20,0
22,0
25,0
26,0
28,0
29,0
32,0
32,0

weight
approx. kg/km

60
80
120
150
180
240
280
340
430
520
600
770
960
1110
1290
1460
1640
1800

11,0
12,0
15,0
16,0
17,0
19,0
20,0
22,0
24,0
26,0
29,0
33,0
35,0
37,0
39,0
42,0
43,0

weight
approx. kg/km

140
200
280
370
490
570
690
900
1100
1300
1690
2120
2510
2900
3290
3690
4060

12,0
14,0
17,0
18,0
21,0
22,0
24,0
27,0
29,0
31,0
35,0
40,0
42,0
46,0
49,0
52,0
53,0

weight
approx. kg/km

200
300
420
560
760
900
1090
1430
1750
2070
2740
3390
4040
4670
5350
6010
6640

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0113

Conductor diameter:

0,9

1,4

1,8

mm

Conductor resistance:

28,9

11,9

7,2

/km

Insulation resistance:

10

10

10

Gkm

145

145

nF/km

(H115)

(H145)

(H145)

600

600

600

420

420

420

Veff/100Hz

2500

2500

2500

V/AC/1min

Mutual capacitance (at f=800Hz): 115

Construction
Conductor:

solid, bare copper wire 0,9 / 1,4 / 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent
monitoring core: grey

Cable make up:

cores cabled together in concentric layers


2 perforated cores ( 0,5 mm; in cables with 14
cores)
wrapping of plastic tape

Operating voltage:
Dielectric strength (cond./cond.)

V/DC

Characteristics of monitoring cores:


Loop resistance:

190

/km

Insulation resistance:
dry cable

Gkm

drown cable

30

k abs.

Sheath:

PE, reinforced (2YV), black

Mutual capacitance (at f=800Hz): N/A

nF/km

Design:

2 up to 200 cores ( 0,9)

Dielectric strength (cond./cond.)

2500

V/50Hz/1min

4 up to 200 cores ( 1,4 / 1,8)

Temperature range:
during installation

-10 up to +60

for stationary conditions

-40 up to +60

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

26

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-2Y2YB2Y ..x1x.. S (H115/H145)
2-140

0,9

1,4

1,8

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y

number of
cores

2x1x.. S
4x1x.. S
7x1x.. S
10x1x.. S
14x1x.. S
20x1x.. S
24x1x.. S
30x1x.. S
40x1x.. S
50x1x.. S
60x1x.. S
80x1x.. S
100x1x.. S
120x1x.. S
140x1x.. S

number of cores

conductor diameter 0.9 mm

conductor diameter 1.4 mm

conductor diameter 1.8 mm

outer diameter
approx. mm

outer diameter
approx mm

outer diameter
approx. mm

2
4
7
10
14
20
24
30
40
50
60
80
100
120
140

12,0
13,0
14,0
15,5
16,0
17,0
19,0
19,0
20,0
22,0
23,0
25,0
28,0
29,0
31,0

weight
approx. kg/km

130
150
170
220
280
340
400
460
550
680
770
970
1170
1350
1540

14,0
15,5
18,0
19,0
21,0
22,0
23,0
25,0
28,0
30,0
-

weight
approx. kg/km

210
290
380
470
620
740
860
1080
1320
1520
-

15,5
17,0
20,0
21,0
24,0
26,0
27,0
30,0
-

weight
approx. kg/km

290
410
540
720
950
1090
1300
1670
-

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0113

Conductor diameter:

0,9

1,4

1,8

mm

Conductor resistance:

28,9

11,9

7,2

/km

Insulation resistance:

10

10

10

Gkm

145

145

nF/km

(H115)

(H145)

(H145)

600

600

600

V/DC

420

420

420

Veff/100Hz

Dielectric strength (cond./cond.): 2500

2500

2500

V/50Hz/1min

Mutual capacitance (at f=800Hz): 115

Construction
Conductor:

solid, bare copper wire 0,9 / 1,4 / 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent
monitoring core: grey

Cable make up:

cores cabled together in concentric layers


2 perforated cores ( 0,5 mm; in cables with 14
cores)
wrapping of plastic tape

Operating voltage:

German Railways
(DB)

PE-insulated, single core, with rodent protection

Characteristics of monitoring cores:


Loop resistance:

190

/km

dry cable

Gkm

drown cable

30

k abs.

Insulation resistance:

Sheath:

PE (2Y), black

Mutual capacitance (at f=800Hz): N/A

nF/km

Armouring:

1 layer galvanized steel tape (0,3 mm) (B) for rodent


protection

Dielectric strength (cond./cond.): 2500

V/50Hz/1min

Temperature range:

Protective cover:

PE (2Y), black

during installation

-10 up to +60

Design:

2 up to 140 cores ( 0,9)

for stationary conditions

-40 up to +60

4 up to 60 cores ( 1,4)
4 up to 40 cores ( 1,8)
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

27

German Railways
PE-insulated, single core, with inductive protection

AJ-2Y2YDB2Y ..x1x0,9 S (H115)


10200

dimension of
conductor

0,9

filling

overall shield,
armouring

cable elements

Type

number of
cores

AJ-2Y2YDB2Y 10x1x0,9 S (H115)


AJ-2Y2YDB2Y 20x1x0,9 S (H115)
AJ-2Y2YDB2Y 30x1x0,9 S (H115)
AJ-2Y2YDB2Y 50x1x0,9 S (H115)
AJ-2Y2YDB2Y 80x1x0,9 S (H115)
AJ-2Y2YDB2Y 120x1x0,9 S (H115)
AJ-2Y2YDB2Y 160x1x0,9 S (H115)
AJ-2Y2YDB2Y 200x1x0,9 S (H115)
AJ-2Y2YDB2Y 10x1x0,9 S (H115)
AJ-2Y2YDB2Y 20x1x0,9 S (H115)
AJ-2Y2YDB2Y 30x1x0,9 S (H115)
AJ-2Y2YDB2Y 50x1x0,9 S (H115)
AJ-2Y2YDB2Y 80x1x0,9 S (H115)
AJ-2Y2YDB2Y 120x1x0,9 S (H115)
AJ-2Y2YDB2Y 160x1x0,9 S (H115)
AJ-2Y2YDB2Y 200x1x0,9 S (H115)

10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200

index of inductiveprotection rk (f=16 2/3 Hz)

number of cores

outer diameter
approx. mm

600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500

19,0
20,0
22,0
25,0
29,0
32,0
35,0
38,0
19,0
20,0
22,0
25,0
29,0
32,0
35,0
38,0

weight
approx. kg/km

620
780
940
1240
1600
2100
2550
2980
690
880
1070
1380
1770
2290
2750
3180

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0113

Conductor diameter:

0,9

mm

Conductor resistance:

28,9

/km

Insulation resistance:

10

Mutual capacitance (at f=800Hz): 115

Construction
Conductor:

solid, bare copper wire 0,9 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent
monitoring core: grey

Cable make up:

cores cabled together in concentric layers


2 perforated cores ( 0,5 mm; in cables with 14
cores)

Sheath:
Screening:

Gkm
nF/km

(H115)
Reduction factor:

acc. DB AG 416.0116

Operating voltage:

600

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

Characteristics of monitoring cores:

wrapping of plastic tape

Loop resistance:

PE (2Y), black

Insulation resistance:

190

/km
Gkm

1 layer copper wires ( 0,9 / 1,2) (D)

dry cable

wrapping of plastic tape

drown cable

30

k abs.

Armouring:

2 layers galvanized steel tape (0,5) (B)

Mutual capacitance (at f=800Hz): N/A

nF/km

Protective cover:

PE (2Y), black

Dielectric strength (cond./cond.):

2500

V/50Hz/1min

10 up to 200 cores ( 0,9)

Temperature range:
during installation

-10 up to +60

for stationary conditions

-40 up to +60

Design:
Laying

Usable for underground laying and drawing into conduits.


Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

28

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
AJ-2Y2YDB2Y ..x1x1,4 S (H145)
10200

dimension of
conductor

1,4

filling

overall shield,
armouring

cable elements

Type

number of
cores

AJ-2Y2YDB2Y 10x1x1,4 S (H145)


AJ-2Y2YDB2Y 20x1x1,4 S (H145)
AJ-2Y2YDB2Y 30x1x1,4 S (H145)
AJ-2Y2YDB2Y 50x1x1,4 S (H145)
AJ-2Y2YDB2Y 80x1x1,4 S (H145)
AJ-2Y2YDB2Y 120x1x1,4 S (H145)
AJ-2Y2YDB2Y 160x1x1,4 S (H145)
AJ-2Y2YDB2Y 200x1x1,4 S (H145)
AJ-2Y2YDB2Y 10x1x1,4 S (H145)
AJ-2Y2YDB2Y 20x1x1,4 S (H145)
AJ-2Y2YDB2Y 30x1x1,4 S (H145)
AJ-2Y2YDB2Y 50x1x1,4 S (H145)
AJ-2Y2YDB2Y 80x1x1,4 S (H145)
AJ-2Y2YDB2Y 120x1x1,4 S (H145)
AJ-2Y2YDB2Y 160x1x1,4 S (H145)
AJ-2Y2YDB2Y 200x1x1,4 S (H145)
AJ-2Y2YDB2Y 50x1x1,4 S (H145)
AJ-2Y2YDB2Y 80x1x1,4 S (H145)
AJ-2Y2YDB2Y 120x1x1,4 S (H145)
AJ-2Y2YDB2Y 160x1x1,4 S (H145)
AJ-2Y2YDB2Y 200x1x1,4 S (H145)

10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
50
80
120
160
200

index of inductiveprotection rk (f=16 2/3 Hz)

outer diameter
approx. mm

600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
400
400
400
400
400

21,0
23,5
27,0
31,0
35,0
41,0
46,0
49,0
21,0
23,5
26,0
31,0
35,0
42,0
46,0
49,0
33,0
38,0
44,0
48,0
52,0

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

Construction

Mutual capacitance (at f=800Hz): 145

Conductor:

solid, bare copper wire 1,4 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent
monitoring core: grey

Cable make up:

cores cabled together in concentric layers


2 perforated cores ( 0,5 mm; in cables with 14
cores)

Sheath:
Screening:

number of cores

weight
approx. kg/km

840
1180
1460
2030
2800
3810
4760
5700
950
1300
1610
2220
3000
4080
5060
6020
2970
3960
5170
6280
7300

DB AG 416.0113

Conductor diameter:

1,4

mm

Conductor resistance:

11,9

/km

Insulation resistance:

10

Gkm
nF/km

(H145)
Reduction factor:

acc. DB AG 416.0116

Operating voltage:

600

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

Characteristics of monitoring cores:

wrapping of plastic tape

Loop resistance:

PE (2Y), black

Insulation resistance:

190

/km

1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D)

dry cable

Gkm

wrapping of plastic tape

drown cable

30

k abs.

Armouring:

2 layers galvanized steel tape (0,5 / 0,8) (B)

Mutual capacitance (at f=800Hz): N/A

nF/km

Protective cover:

PE (2Y), black

Dielectric strength (cond./cond.):

2500

V/50Hz/1min

Design:

10 up to 200 cores ( 1,4)

Temperature range:
during installation

-10 up to +60

for stationary conditions

-40 up to +60

Laying

German Railways
(DB)

PE-insulated, single core, with inductive protection

Usable for underground laying and drawing into conduits.


Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

29

German Railways
PE-insulated, single core, with inductive protection

AJ-2Y2YDB2Y ..x1x1,8 S (H145)


10200

dimension of
conductor

1,8

filling

overall shield,
armouring

cable elements

Type

number of
cores

AJ-2Y2YDB2Y 10x1x1,8 S (H145)


AJ-2Y2YDB2Y 20x1x1,8 S (H145)
AJ-2Y2YDB2Y 30x1x1,8 S (H145)
AJ-2Y2YDB2Y 50x1x1,8 S (H145)
AJ-2Y2YDB2Y 80x1x1,8 S (H145)
AJ-2Y2YDB2Y 120x1x1,8 S (H145)
AJ-2Y2YDB2Y 160x1x1,8 S (H145)
AJ-2Y2YDB2Y 200x1x1,8 S (H145)
AJ-2Y2YDB2Y 10x1x1,8 S (H145)
AJ-2Y2YDB2Y 20x1x1,8 S (H145)
AJ-2Y2YDB2Y 30x1x1,8 S (H145)
AJ-2Y2YDB2Y 50x1x1,8 S (H145)
AJ-2Y2YDB2Y 80x1x1,8 S (H145)
AJ-2Y2YDB2Y 120x1x1,8 S (H145)
AJ-2Y2YDB2Y 160x1x1,8 S (H145)
AJ-2Y2YDB2Y 200x1x1,8 S (H145)
AJ-2Y2YDB2Y 30x1x1,8 S (H145)
AJ-2Y2YDB2Y 50x1x1,8 S (H145)
AJ-2Y2YDB2Y 80x1x1,8 S (H145)
AJ-2Y2YDB2Y 120x1x1,8 S (H145)
AJ-2Y2YDB2Y 160x1x1,8 S (H145)
AJ-2Y2YDB2Y 200x1x1,8 S (H145)

10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
30
50
80
120
160
200

index of inductiveprotection rk (f=16 2/3 Hz)

outer diameter
approx. mm

600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
400
400
400
400
400
400

23,0
27,0
30,0
36,0
41,0
48,0
54,0
58,0
23,0
27,0
30,0
36,0
42,0
49,0
55,0
59,0
32,0
38,0
44,0
51,0
57,0
61,0

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

Construction

Mutual capacitance (at f=800Hz): 145

Conductor:

solid, bare copper wire 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent
monitoring core: grey

Cable make up:

cores cabled together in concentric layers


2 perforated cores ( 0,5 mm; in cables with 14
cores)

number of cores

weight
approx. kg/km

950
1400
1770
2550
3620
5010
6350
7600
1050
1540
1930
2730
3860
5290
6660
7960
2560
3630
4850
6410
7910
9300

DB AG 416.0113

Conductor diameter:

1,8

mm

Conductor resistance:

7,2

/km

Insulation resistance:

10

Gkm
nF/km

(H145)
Reduction factor:

acc. DB AG 416.0116

Operating voltage:

600

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

Characteristics of monitoring cores:

wrapping of plastic tape

Loop resistance:

Sheath:

PE (2Y), black

Insulation resistance:

Screening:

1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D)

dry cable

Gkm

wrapping of plastic tape

drown cable

30

k abs.

190

/km

Armouring:

2 layers galvanized steel tape (0,5 / 0,8) (B)

Mutual capacitance (at f=800Hz): N/A

nF/km

Protective cover:

PE (2Y), black

Dielectric strength (cond./cond.):

2500

V/50Hz/1min

Design:

10 up to 200 cores ( 0,9)

Temperature range:
during installation

-10 up to +60

for stationary conditions

-40 up to +60

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
30

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-2Y2YV ..x1x.. S (H95)
10-50

1,4

1,8

dimension of
conductor

number of cores

filling

overall shield,
armouring

cable elements

conductor diameter 1.4 mm

conductor diameter 1.8 mm

Type

number of
cores

outer diameter
approx mm

weight
approx. kg/km

outer diameter
approx. mm

weight
approx. kg/km

A-2Y2YV 10x1x.. S (H95)


A-2Y2YV 14x1x.. S (H95)
A-2Y2YV 20x1x.. S (H95)
A-2Y2YV 30x1x.. S (H95)
A-2Y2YV 50x1x.. S (H95)

10
14
20
30
50

16,0
18,0
20,0
24,0
29,0

320
420
570
800
1270

19,0
21,0
24,0
28,0
36,0

470
640
860
1240
2010

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

Construction
Conductor:

solid, bare copper wire 1,4 / 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent
monitoring core: grey

Cable make up:

cores cabled together in concentric layers


2 perforated cores ( 0,5 mm; in cables with 14
cores)
wrapping of plastic tape

German Railways
(DB)

PE-insulated, single core, with reinforced sheath

DB AG 416.0114

Conductor diameter:

1,4

1,8

mm

Conductor resistance:

11,9

7,2

/km

Insulation resistance:

10

10

Gkm

Mutual capacitance (at f=800Hz): 95

95

nF/km

600

600

V/DC

420

420

Veff/100Hz

2500

2500

V/50Hz/1min

(H95)
Operating voltage:
Dielectric strength (cond./cond.):

Characteristics of monitoring cores:


Loop resistance:

190

/km

Insulation resistance:
dry cable

Gkm

drown cable

30

k abs.

Sheath:

PE, reinforced (2YV), black

Mutual capacitance (at f=800Hz): N/A

nF/km

Design:

10 up to 50 cores ( 1,4 / 1,8)

Dielectric strength (cond./cond.):

2500

V/50Hz/1min

Temperature range:
Laying

during installation

-10 up to +60

Usable for underground laying and drawing into conduits.

for stationary conditions

-40 up to +60

Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

31

German Railways
PE-insulated, single core, with rodent protection

A-2Y2YB2Y ..x1x.. S (H95)


10-20

1,4

1,8

dimension of
conductor

number of cores

filling

overall shield,
armouring

cable elements

conductor diameter 1.4 mm

conductor diameter 1.8 mm

Type

number of
cores

outer diameter
approx mm

weight
approx. kg/km

outer diameter
approx. mm

weight
approx. kg/km

A-2Y2YB2Y 10x1x.. S (H95)


A-2Y2YB2Y 14x1x.. S (H95)
A-2Y2YB2Y 20x1x.. S (H95)

10
14
20

18,0
20,0
22,0

450
570
750

21,0
23,0
-

650
820
-

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0114

Conductor diameter:

1,4

1,8

mm

Conductor resistance:

11.9

7.2

/km

Insulation resistance:

10

10

Gkm

Construction

Mutual capacitance (at f=800Hz): 95

95

nF/km

600

600

V/DC

420

420

Veff/100Hz

Dielectric strength (cond./cond.): 2500

2500

V/50Hz/1min

Conductor:

solid, bare copper wire 1,4 / 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent
monitoring core: grey

Cable make up:

cores cabled together in concentric layers


2 perforated cores ( 0,5 mm; in cables with 14
cores)
wrapping of plastic tape

(H95)
Operating voltage:

Characteristics of monitoring cores:


Loop resistance:

190

/km

dry cable

Gkm

drown cable

30

k abs.

Insulation resistance:

Sheath:

PE (2Y), black

Mutual capacitance (at f=800Hz:) N/A

nF/km

Armouring:

1 layer galvanized steel tape (0,3 mm) (B) for rodent


protection

Dielectric strength (cond./cond.): 2500

V/50Hz/1min

Temperature range:

Protective cover:

PE (2Y), black

during installation

-10 up to +60

Design:

10 up to 20 cores ( 1,4)
10 up to 14 cores ( 1,8)

for stationary conditions

-40 up to +60

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

32

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
AJ-2Y2YDB2Y ..x1x1,4 S (H95)
10-50

dimension of
conductor

1,4

filling

overall shield,
armouring

cable elements

Type

AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y

number of
cores

10x1x1,4
14x1x1,4
20x1x1,4
30x1x1,4
50x1x1,4
30x1x1,4
50x1x1,4

S
S
S
S
S
S
S

(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)

10
14
20
30
50
30
50

index of inductiveprotection rk (f=16 2/3 Hz)

22,0
24,0
27,0
30,0
35,0
32,0
38,0

Application

Technical Details (at 20C)


Standard:

Construction
Conductor:

solid, bare copper wire 1,4 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent
monitoring core: grey

Cable make up:

cores cabled together in concentric layers


2 perforated cores ( 0,5 mm; in cables with 14
cores)

outer diameter
approx. mm

500
500
500
500
500
400
400

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

number of cores

weight
approx. kg/km

990
1130
1360
1680
2300
2350
3180

DB AG 416.0114

Conductor diameter:

1,4

mm

Conductor resistance:

11,9

/km

Insulation resistance:

10

Gkm

Mutual capacitance (at f=800Hz): 95

nF/km

(H95)
Reduction factor:

acc. DB AG 416.0116

Operating voltage:

600

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

Characteristics of monitoring cores:

wrapping of plastic tape

Loop resistance:

Sheath:

PE (2Y), black

Insulation resistance:

Screening:

1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D)

dry cable

Gkm

wrapping of plastic tape

drown cable

30

k abs.

190

/km

Armouring:

2 layers galvanized steel tape (0,5 / 0,8) (B)

Mutual capacitance (at f=800Hz): N/A

nF/km

Protective cover:

PE (2Y), black

Dielectric strength (cond./cond.):

2500

V/50Hz/1min

Design:

10 up to 50 cores ( 1,4)

Temperature range:
during installation

-10 up to +60

for stationary conditions

-40 up to +60

Laying

German Railways
(DB)

PE-insulated, single core, with inductive protection

Usable for underground laying and drawing into conduits.


Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

33

German Railways
PE-insulated, single core, with inductive protection

AJ-2Y2YDB2Y ..x1x1,8 S (H95)


10-50

dimension of
conductor

1,8

filling

overall shield,
armouring

cable elements

Type

AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y

number of
cores

10x1x1,8
14x1x1,8
20x1x1,8
30x1x1,8
50x1x1,8
30x1x1,8
50x1x1,8

S
S
S
S
S
S
S

(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)

10
14
20
30
50
30
50

index of inductiveprotection rk (f=16 2/3 Hz)

number of cores

outer diameter
approx. mm

500
500
500
500
500
400
400

25,0
27,0
30,0
34,0
42,0
37,0
44,0

weight
approx. kg/km

1380
1620
1990
2550
3670
3510
4780

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.

Standard:

DB AG 416.0114

Conductor diameter:

1,8

mm

Conductor resistance:

7,2

/km

Insulation resistance:

10

Gkm

Mutual capacitance (at f=800Hz): 95

nF/km

Construction
Conductor:

solid, bare copper wire 1,8 mm

Insulation:

PE (2Y)

Colour code:

tracer core in each layer: blue


other cores: transparent
monitoring core: grey

Cable make up:

cores cabled together in concentric layers

(H95)
Reduction factor:

acc. DB AG 416.0116

Operating voltage:

600

V/DC

420

Veff/100Hz

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

Dielectric strength:

2 perforated cores ( 0,5 mm; in cables with 14


cores)

Characteristics of monitoring cores:

wrapping of plastic tape

Loop resistance:

Sheath:

PE (2Y), black

Insulation resistance:

Screening:

1 layer copper wires ( 0,9 / 1,2 / 1,8) (D)


wrapping of plastic tape

190

/km

dry cable

Gkm

drown cable

30

k abs.

Armouring:

2 layers galvanized steel tape (0,5 / 0,8) (B)

Mutual capacitance (at f=800Hz): N/A

nF/km

Protective cover:

PE (2Y), black

Dielectric strength (cond./cond.):

2500

V/50Hz/1min

Design:

10 up to 50 cores ( 1,8)

Temperature range:
during installation

-10 up to +60

for stationary conditions

-40 up to +60

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

34

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-2Y(L)2YV ..x4x.. S (H45)
2-80

0,9

1,4

dimension of
conductor

number of
double cores

filling

overall shield,
armouring

cable elements

conductor diameter 0.9 mm

conductor diameter 1.4 mm

Type

number of
double cores

outer diameter
approx mm

weight
approx. kg/km

outer diameter
approx. mm

weight
approx. kg/km

A-2Y(L)2YV 1x4x.. S
A-2Y(L)2YV 3x4x.. S
A-2Y(L)2YV 5x4x.. S
A-2Y(L)2YV 7x4x.. S
A-2Y(L)2YV 10x4x.. S
A-2Y(L)2YV 14x4x.. S
A-2Y(L)2YV 20x4x.. S
A-2Y(L)2YV 30x4x.. S
A-2Y(L)2YV 40x4x.. S

2
6
10
14
20
28
40
60
80

10,0
15,0
17,0
19,0
22,0
25,0
28,0
34,0
38,0

120
220
330
410
560
730
980
1410
1820

12,0
19,0
22,0
24,0
29,0
33,0
39,0
46,0
53,0

170
410
620
800
1090
1490
2040
2950
3900

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of alternating currents up to 90 kHz in systems, which require
a high symmetry against each other and outside disturbers as well as in relation to the earth potential.

Standard:

DB AG 416.0115

Conductor diameter:

0,9

1,4

mm

Loop resistance:

56,6

23,4

/km

Insulation resistance:

10

10

Gkm

Mutual capacitance (at f=800Hz):

45

45

nF/km

650

pF/500m

500

pF/500m

Construction

(H45)

Conductor:

solid, bare copper wire 0,9 / 1,4 mm

Insulation:

PE (2Y)

Capacitance unbalance:k1

100% 650

Identification:

basic colour grey, ring marking according to DB AG


416.0116, monitoring cores: grey

(at f=800Hz)

50%

Capacitance unbalance:k9-12 100% 500

Cable make up:

cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked
with an open blue helix. 2 perforated cores ( 0,5 mm;
in cables with 7 quads)
wrapping of plastic tape
tinned copper wire ( 0,4 mm)

Sheath:

aluminium laminated PE-sheath, reinforced ((L)2YV),


black

Design:

1 up to 40 quads ( 0,9 / 1,4)

Laying
Usable for underground laying and drawing into conduits.

1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL


2nd line (if cable >20mm): SIGNAL

pF/500m

150

(at f=800Hz)

50%

Capacitance unbalance:e1/2

100% 1300

1300

pF/500m

ea1/2 100% 1300

pF/500m

150
1300

pF/500m

100% 3,3

2,6

db/km

FEXT:

100% 58

33

db/km

(at f=90kHz)

80%

(at f=800Hz)

Image attenuation constant:


(at f=90kHz)

db/km

62

Dielectric strength:
conductor/conductor

2500

2500

V/50Hz/1min

conductor/shield

2500

2500

V/50Hz/1min

Characteristics of monitoring cores:


Loop resistance:

Marking

German Railways
(DB)

PE-insulated, star-quads, with reinforced sheath

190

/km

dry cable

Gkm

drown cable

30

k abs.

2500

V/50Hz/1min

during installation

-10 up to +60

for stationary conditions

-40 up to +60

Insulation resistance:

Dielectric strength (cond./cond.):


Temperature range:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

35

German Railways
PE-insulated, star-quads, with rodent protection

A-2Y(L)2YB2Y ..x4x.. S (H45)


2-28

0,9

1,4

dimension of
conductor

filling

overall shield,
armouring

cable elements

conductor diameter 0.9 mm

conductor diameter 1.4 mm

Type

number of
double cores

outer diameter
approx mm

weight
approx. kg/km

outer diameter
approx. mm

weight
approx. kg/km

A-2Y(L)2YB2Y 1x4x.. S
A-2Y(L)2YB2Y 3x4x.. S
A-2Y(L)2YB2Y 5x4x.. S
A-2Y(L)2YB2Y 7x4x.. S
A-2Y(L)2YB2Y 10x4x.. S
A-2Y(L)2YB2Y 14x4x.. S

2
6
10
14
20
28

12,0
17,0
19,0
21,0
24,0
27,0

190
330
470
580
750
940

14,0
21,0
24,0
26,0
-

260
570
820
1020
-

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of alternating currents up to 90 kHz in systems, which require
a high symmetry against each other and outside disturbers as well as in relation to the earth potential.

Standard:

Construction
Conductor:

solid, bare copper wire 0,9 / 1,4 mm

Insulation:

DB AG 416.0115

Conductor diameter:

0,9

1,4

mm

Loop resistance:

56,6

23,4

/km

Insulation resistance:

10

10

Gkm

Mutual capacitance (at f=800Hz):

45

45

nF/km

(H45)

PE (2Y)

Capacitance unbalance: k1

100%

650

Identification:

basic colour grey, ring marking according to DB AG


416.0116, monitoring cores: grey

(at f=800Hz)

50%

150

Capacitance unbalance: k9-12 100%

500

Cable make up:

cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked
with an open blue helix. 2 perforated cores ( 0,5 mm;
in cables with 7 quads)

(at f=800Hz)

150

pF/500m

Capacitance unbalance: e1/2 100%

1300 1300

pF/500m

ea1/2 100%

1300 1300

pF/500m

3.3

2.6

db/km

33

wrapping of plastic tape


tinned copper wire ( 0,4 mm)

(at f=800Hz)

50%

Image attenuation constant:

100%

650

pF/500m
pF/500m

500

pF/500m

(at f=90kHz)
FEXT:

100%

58

(at f=90kHz)

80%

62

db/km

Sheath:

aluminium laminated PE-sheath, ((L)2Y), black

Armouring:

1 layer galvanized steel tape (0,3 mm) (B) for rodent


protection

Protective cover:

PE (2Y), black

conductor/conductor

2500

2500

V/50Hz/1min

Design:

1 up to 14 quads ( 0,9)

conductor/shield

2500

2500

V/50Hz/1min

1 up to 7 quads ( 1,4)

Usable for underground laying and drawing into conduits.

db/km

Dielectric strength:

Characteristics of monitoring cores:


Loop resistance:

Laying

36

number of
double cores

190

/km

Insulation resistance:
dry cable

Gkm

drown cable

30

k abs.

2500

V/50Hz/1min

during installation

-10 up to +60

for stationary conditions

-40 up to +60

Marking

Dielectric strength (cond./cond.):

1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL


2nd line (if cable >20mm): SIGNAL

Temperature range:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
AJ-2Y(L)2YDB2Y ..x4x0,9 S (H45)
6-80

0,9

Type

number of
double cores

AJ-2Y(L)2YDB2Y 3x4x0,9 S (H45)


AJ-2Y(L)2YDB2Y 5x4x0,9 S (H45)
AJ-2Y(L)2YDB2Y 10x4x0,9 S (H45)
AJ-2Y(L)2YDB2Y 20x4x0,9 S (H45)
AJ-2Y(L)2YDB2Y 30x4x0,9 S (H45)
AJ-2Y(L)2YDB2Y 40x4x0,9 S (H45)
AJ-2Y(L)2YDB2Y 10x4x0,9 S (H45)
AJ-2Y(L)2YDB2Y 20x4x0,9 S (H45)
AJ-2Y(L)2YDB2Y 30x4x0,9 S (H45)
AJ-2Y(L)2YDB2Y 40x4x0,9 S (H45)

6
10
20
40
60
80
20
40
60
80

number of
double cores

dimension of
conductor

filling

cable elements

overall shield,
armouring

index of inductiveprotection rk (f=16 2/3 Hz)

outer diameter
approx. mm

600
600
600
600
600
600
400
400
400
400

21,0
23,0
28,0
35,0
40,0
45,0
31,0
38,0
43,0
48,0

weight
approx. kg/km

800
1010
1430
2130
2800
3580
2250
3240
4080
4800

Application

Technical Details (at 20C)

for general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of alternating currents up to 90 kHz in systems, which require
a high symmetry against each other and outside disturbers as well as in relation to the earth potential.

Standard:

DB AG 416.0115

Conductor diameter:

0,9

mm

Loop resistance:

56,6

/km

Insulation resistance:

10

Gkm

Mutual capacitance (at f=800Hz):

45

nF/km

Construction
Conductor:

solid, bare copper wire 0,9 mm

Insulation:

PE (2Y)

Identification:

basic colour grey, ring marking according to DB AG


416.0116, monitoring cores: grey

Cable make up:

cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked
with an open blue helix. 2 perforated cores ( 0,5 mm;
in cables with 7 quads)
wrapping of plastic tape
tinned copper wire ( 0,4 mm)

Sheath:

aluminium laminated PE-sheath, ((L)2Y), black

Screening:

1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D)


wrapping of plastic tape

Armouring:

2 layers galvanized steel tape (0,5/0,8) (B)

Protective cover:

PE (2Y), black

Design:

6 up to 80 double cores ( 0,9)

Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL

German Railways
(DB)

PE-insulated, star quads, with inductive protection

(H45)
Capacitance unbalance: k1

100%

650

(at f=800Hz)

50%

150

pF/500m

500

pF/500m

Capacitance unbalance: k9-12 100%

pF/500m

(at f=800Hz)

50%

150

pF/500m

Capacitance unbalance: e1/2

100%

1300

pF/500m

ea1/2 100%

1300

pF/500m

100%

3.3

db/km

FEXT:

100%

58

db/km

(at f=90kHz)

80%

62

db/km

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

190

/km

dry cable

Gkm

drown cable

30

k abs.

2500

V/50Hz/1min

during installation

-10 up to +60

for stationary conditions

-40 up to +60

(at f=800Hz)

Image attenuation constant:


(at f=90kHz)

Dielectric strength:

Characteristics of monitoring cores:


Loop resistance:
Insulation resistance:

Dielectric strength (cond./cond.):


Temperature range:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

37

German Railways
PE-insulated, star quads, with inductive protection

AJ-2Y(L)2YDB2Y ..x4x1,4 S (H45)


6-80

1,4

Type

number of
double cores

AJ-2Y(L)2YDB2Y 3x4x1,4 S (H45)


AJ-2Y(L)2YDB2Y 5x4x1,4 S (H45)
AJ-2Y(L)2YDB2Y 10x4x1,4 S (H45)
AJ-2Y(L)2YDB2Y 20x4x1,4 S (H45)
AJ-2Y(L)2YDB2Y 30x4x1,4 S (H45)
AJ-2Y(L)2YDB2Y 40x4x1,4 S (H45)
AJ-2Y(L)2YDB2Y 5x4x1,4 S (H45)
AJ-2Y(L)2YDB2Y 10x4x1,4 S (H45)
AJ-2Y(L)2YDB2Y 20x4x1,4 S (H45)
AJ-2Y(L)2YDB2Y 30x4x1,4 S (H45)
AJ-2Y(L)2YDB2Y 40x4x1,4 S (H45)

6
10
20
40
60
80
10
20
40
60
80

dimension of
conductor

filling

cable elements

overall shield,
armouring

index of inductiveprotection rk (f=16 2/3 Hz)

outer diameter
approx. mm

500
500
500
500
500
500
400
400
400
400
400

25,0
29,0
37,0
47,0
54,0
61,0
31,0
39,0
49,0
56,0
63,0

weight
approx. kg/km

1350
1760
2620
4040
5330
6550
2470
3610
5260
6690
8070

Application

Technical Details (at 20C)

For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of alternating currents up to 90 kHz in systems, which require
a high symmetry against each other and outside disturbers as well as in relation to the earth potential.

Standard:

DB AG 416.0115

Conductor diameter:

1,4

mm

Loop resistance:

23,4

/km

Insulation resistance:

10

Gkm

Construction

Mutual capacitance (at f=800Hz):

45

nF/km

(H45)

Conductor:

solid, bare copper wire 1,4 mm

Insulation:

PE (2Y)

Capacitance unbalance: k1

100%

650

pF/500m

Identification:

basic colour grey, ring marking according to DB AG


416.0116, monitoring cores: grey

(at f=800Hz)
Capacitance unbalance: k9-12 100%

500

pF/500m

Cable make up:

cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked
with an open blue helix. 2 perforated cores ( 0,5 mm;
in cables with 7 quads)

(at f=800Hz)
Capacitance unbalance: e1/2 100%

1300

pF/500m

ea1/2 100%

1300

pF/500m

100%

2,6

db/km

100%

33

db/km

Sheath:
Screening:

(at f=800Hz)

wrapping of plastic tape

Image attenuation constant:

tinned copper wire ( 0,4 mm)

(at f=90kHz)

aluminium laminated PE-sheath ((L)2Y), black.

FEXT

1 layer copper wires ( 0,9 / 1,2 / 1,4 / 1,8) (D)

(at f=90kHz)

wrapping of plastic tape

Dielectric strength:

2 layers galvanized steel tape (0,5 / 0,8) (B)

conductor/conductor

2500

V/50Hz/1min

Protective cover:

PE (2Y), black

conductor/shield

2500

V/50Hz/1min

Design:

6 up to 80 double cores ( 0,9)

190

/km

dry cable

Gkm

drown cable

30

k abs.

2500

V/50Hz/1min

during installation

-10 up to +60

for stationary conditions

-40 up to +60

Armouring:

Characteristics of monitoring cores:


Loop resistance:

Laying
Usable for underground laying and drawing into conduits.

38

number of
double cores

Insulation resistance:

Marking

Dielectric strength (cond./cond.):

1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL


2nd line (if cable >20mm): SIGNAL

Temperature range:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
PE-foam skin insulated, star quads, reinforced sheath A-02YSTF(L)2YV ..x4x0,9 STI TNP 02
mutual capacitance

10-60

TF

dimension of
copper conductor

0,9

A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV

5x4x0,9 STI TNP 02


10x4x0,9 STI TNP 02
16x4x0,9 STI TNP 02
19x4x0,9 STI TNP 02
24x4x0,9 STI TNP 02
30x4x0,9 STI TNP 02

filling

overall shield,
armouring

cable elements

Type

number of
double cores

number of
double cores

outer diameter
approx. mm

weight
approx. kg/km

10
20
32
38
48
60

20,0
28,0
33,0
35,0
41,0
43,0

300
570
790
940
1170
1390

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.

Standard:

Arcor TNP 02

Conductor diameter:

0,9

mm

Loop resistance:

56,6

/km

Resistance difference:

0,30

/km

Construction
Conductor:

solid, bare copper wire 0,9 mm

Insulation resistance:

Gkm

Insulation:

PE-Foam skin (02YS)

10

Mutual capacitance:

nF/km

Colour code :

a core: YE

34

Capacitance unbalance:
k1

110

pF/km

k9-12

110

pF/km

ea1/2

1300

pF/km

b core: RD
c core: GN
d core: BU
Cable make up:

Sheath:

cores twisted to star-quads, quads stranded together


in concentric layers, 2 perforated cores ( 0,5 mm),
wrapping with swellable tape (TF)
aluminium laminated PE-sheath, reinforced black
((L)2YV)

Marking

German Railways
(DB)

C34

Attenuation:
0,6

db/km

Operating voltage:

800 Hz

250

Veff

Near-end crosstalk:

45

dB/abs.

Far-end crosstalk:

45

dB/km

Dielectric strength:

1. line: handset symbol - <meter>

conductor/conductor

500

V/50Hz/1min

2. line: ( >20mm) handset symbol

conductor/shield

2000

V/50Hz/1min

Characteristics of monitoring cores:


Loop resistance:

190

/km

Insulation resistance:
dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Dielectric strength:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

39

German Railways
PE-foam skin insulated,star quads,with reinforced sheath

A-02YSTF(L)2YV ..x4x1,4 / ..x4x0,9 STI A TNP 02

C34 C36

0.9

mutual capacitance

1.4

16-66

dimension of
conductor

TF

A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV

1x4x1,4
2x4x1,4
3x4x1,4
4x4x1,4
5x4x1,4
3x4x1,4

/ 7x4x0,9 STI A TNP 02


/ 11x4x0,9 STI A TNP 02
/ 12x4x0,9 STI A TNP 02
/ 13x4x0,9 STI A TNP 02
/ 16x4x0,9 STI A TNP 02
/ 30x4x0,9 STI A TNP 02

filling

overall shield,
armouring

cable elements

Type

number of
double cores

number of
double cores

outer diameter
approx. mm

weight
approx. kg/km

16
26
30
34
42
66

25,0
34,0
35,0
37,0
40,0
47,0

510
820
940
1080
1300
1690

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.

Standard:

Arcor TNP 02

Conductor diameter:

0,9

1,4

mm

Construction

Loop resistance:

56,6

23,4

/km

0,30

0,20

/km
Gkm

Conductor:

solid, bare copper wire 0,9 / 1,4 mm

Resistance difference:

Insulation:

PE-Foam skin (02YS)

Insulation resistance:

Colour code :

Cable make up:

Sheath:

a core: YE

L>200m

10

10

b core: RD

100m L 200m

25

25

Gkm

c core: GN

L<100m

30

30

Gkm

34

36

nF/km

k1

110

110

pF/km

k9-12

110

110

pF/km

ea1/2

1300

1300

pF/km
db/km

d core: BU

Mutual capacitance:

cores twisted to star-quads, quads stranded together


in concentric layers, 2 perforated cores ( 0,5 mm),
wrapping with swellable tape (TF)

Capacitance unbalance:

aluminium laminated PE-sheath, reinforced, black


((L)2YV)

Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol

Attenuation:
800 Hz

0,6

0,4

Operating voltage:

250

250

Veff

Near-end crosstalk:

45

45

dB abs.

Far-end crosstalk:

45

45

dB/km

Dielectric strength:
conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Characteristics of monitoring cores:


Loop resistance:

190

/km

dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Insulation resistance:

Dielectric strength:

40

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways

C34

0,9

mutual capacitance

10

number of
double cores

dimension of
copper conductor

TF

filling

overall shield,
armouring

cable elements

Type

number of
double cores

outer diameter
approx. mm

weight
approx. kg/km

A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP 02

10

22,2

521

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.

Standard:

Arcor TNP 02

Conductor diameter:

0,9

mm

Construction

Loop resistance:

56,6

/km

Conductor:

solid, bare copper wire 0,9 mm

Resistance difference:

0,30

/km

Insulation:

PE-Foam skin (02YS)

Insulation resistance:

10

Gkm

Colour code :

a core: YE

Mutual capacitance:

34

nF/km

b core: RD

Capacitance unbalance:

Cable make up:

c core: GN

k1

110

pF/km

d core: BU

k9-12

110

pF/km

cores twisted to star-quads, quads stranded together


in concentric layers, 2 perforated cores ( 0,5 mm),
wrapping with swellable tape (TF)

ea1/2

1300

pF/km

Sheath:

aluminium laminated PE-sheath, black ((L)2Y)

Armouring:

one layer galvanized steel tape (B)

Protective cover:

PE, black (2Y)

Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol

German Railways
(DB)

PE-foam skin insulated, star quads, with rodent protection A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP 02

Attenuation:
0,6

db/km

Operating voltage:

800 Hz

250

Veff

Near-end crosstalk:

45

dB/abs.

Far-end crosstalk:

45

dB/km

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Dielectric strength:

Characteristics of monitoring cores:


Loop resistance:

190

/km

dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Insulation resistance:

Dielectric strength:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

41

German Railways
PE-foam skin insulated, star quads, with rodent protection

A-02YSTF(L)2Y(SR)2Y 5x4x0,9 STI TNP 02

C34

0.9

mutual capacitance

10

number of
double cores

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

number of
double cores

outer diameter
approx. mm

weight
approx. kg/km

A-02YSTF(L)2Y(SR)2Y 5x4x0,9 STI TNP 02

10

23,2

495,1

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.

Standard:

Arcor TNP 02

Conductor diameter:

0,9

mm

Loop resistance:

56,6

/km

Resistance difference:

0,30

/km

Construction
Conductor:

solid, bare copper wire 0,9 mm

Insulation:

PE-Foam skin (02YS)

L>200m

10

Gkm

Colour code :

a core: YE

100m L 200m

25

Gkm

b core: RD

L<100m

30

Gkm

34

nF/km

Cable make up:

Insulation resistance:

c core: GN

Mutual capacitance:

d core: BU

Capacitance unbalance:

cores twisted to star-quads, quads stranded together


in concentric layers, 2 perforated cores ( 0,5 mm),
wrapping with swellable tape

Sheath:

aluminium laminated PE-sheath, black ((L)2Y)

Armouring:

one layer of corrugated steel tape ((SR)), wrapping of


tape

Protective cover:

PE, black (2Y)

k1

110

pF/km

k9-12

110

pF/km

ea1/2

1300

pF/km

0,6

db/km

Attenuation:
800 Hz
Operating voltage:

250

Veff

Near-end crosstalk:

45

dB abs.

Marking

Far-end crosstalk:

45

dB/km

1. line: handset symbol - <meter>

Dielectric strength:
conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

2. line: ( >20mm) handset symbol

Characteristics of monitoring cores:


Loop resistance:

190

/km

dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Insulation resistance:

Dielectric strength:

42

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
AJ-02YSTF(L)2YDB2Y ..x4x0,9 STI A TNP 02

C34

mutual capacitance

20-60

dimension of
copper conductor

0,9

TF

AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y

10x4x0,9
16x4x0,9
19x4x0,9
24x4x0,9
30x4x0,9

STI
STI
STI
STI
STI

TNP
TNP
TNP
TNP
TNP

02
02
02
02
02

filling

overall shield,
armouring

cable elements

Type

number of
double cores

number of
double cores

outer diameter
approx. mm

weight
approx. kg/km

20
32
38
48
60

37,0
41,0
43,0
49,0
52,0

1730
2110
2260
2750
3060

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.

Standard:

Arcor TNP 02

Conductor diameter:

0,9

mm

Construction

Loop resistance:

56,6

/km

Conductor:

solid, bare copper wire 0,9 mm

Resistance difference:

0,30

/km

Insulation:

PE-Foam skin (02YS)

Insulation resistance:

10

Gkm

Colour code :

a core: YE

Mutual capacitance:

34

nF/km

b core: RD

Capacitance unbalance:

Cable make up:

c core: GN

k1

110

pF/km

d core: BU

k9-12

110

pF/km

cores twisted to star-quads, quads stranded together


in concentric layers, 2 perforated cores ( 0,5 mm),
wrapping with swellable tape (TF)

ea1/2

1300

pF/km

Sheath:

aluminium laminated PE-sheath, black ((L)2Y)

Screening:

1 layer copper wires (D), wrapping with tape

Armouring:

two layers of galvanized steel tape (B), wrapping of


tape

Protective cover:

PE, black (2Y)

Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol

German Railways
(DB)

PE-foam skin insulated, star quads, with inductive protection

Attenuation:
0,6

db/km

Operating voltage:

800 Hz

250

Veff

Near-end crosstalk:

45

dB/abs.

Far-end crosstalk:

45

dB/km

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Dielectric strength:

Characteristics of monitoring cores:


Loop resistance:

190

/km

Insulation resistance:
dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Dielectric strength:

Reduction factor:

according to Arcor TNP 05

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

43

German Railways
PE-foam skin insulated, quads, inductive protection

AJ-02YSTF(L)2YDB2Y ..x4x1,4 / ..x4x0,9 STI A TNP 02

C34 C36

1.4

0.9

mutual capacitance

16-66

dimension of
conductor

TF

number of
double cores

AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y

1x4x1,4 /
2x4x1,4 /
3x4x1,4 /
4x4x1,4 /
5x4x1,4 /
3x4x1,4 /

7x4x0.9
11x4x0.9
12x4x0.9
13x4x0.9
16x4x0.9
30x4x0.9

outer diameter
approx. mm

16
26
30
34
42
66

filling

overall shield,
armouring

cable elements

Type

number of
double cores

34.0
42.0
44.0
46.0
48.0
56.0

weight
approx. kg/km

1490
2030
2140
2330
2580
3300

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.

Standard:

Arcor TNP 02

Conductor diameter:

0,9

1,4

mm

Construction

Loop resistance:

56,6

23,4

/km

0,30

0,20

/km

Conductor:

solid, bare copper wire 0,9 / 1,4 mm

Resistance difference:

Insulation:

PE-Foam skin (02YS)

Insulation resistance:

Colour code :

Cable make up:

a core: YE

L>200m

10

10

Gkm

b core: RD

100m L 200m

25

25

Gkm

c core: GN

L<100m

30

30

Gkm

34

36

nF/km

d core: BU

Mutual capacitance:

cores twisted to star-quads, quads stranded together


in concentric layers, 2 perforated cores ( 0,5 mm),
wrapping with swellable tape (TF)

Capacitance unbalance:

Sheath:

aluminium laminated PE-sheath, black ((L)2Y)

Screening:

1 layer copper wires, wrapping with tape (D)

Armouring:

2 layers galvanized steel tape (B), wrapping of tape

Protective cover:

PE, black (2Y)

Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol

110

110

pF/km

k9-12

110

110

pF/km

ea1/2

1300

1300

pF/km
db/km

Attenuation:
800 Hz

0,6

0,4

Operating voltage:

250

250

Veff

Near-end crosstalk:

45

45

dB abs.

Far-end crosstalk:

45

45

dB/km

Dielectric strength:
conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Characteristics of monitoring cores:


Loop resistance:

190

/km

dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Insulation resistance:

Dielectric strength:

Reduction factor:

44

according Arcor TNP 05

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-02YS(L)2YV x4x0,7 mm STI TNP 03

C34
#
0,7

mutual capacitance

6-14

number of
double cores

dimension of
copper conductor

filling

cable elements

overall shield,
armouring

Type

number of
double cores

outer diameter
approx. mm

weight
approx. kg/km

A-02YS(L)2YV 3x4x0,7 mm STI TNP 03


A-02YS(L)2YV 5x4x0,7 mm STI TNP 03
A-02YS(L)2YV 7x4x0,7 mm STI TNP 03

6
10
14

20,0
24,0
26,0

290
420
510

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances, with
high resistance against vibrations. The cable is fixed directly at the rail.

Standard:
Conductor cross section:

0,7

mm

Construction

Loop resistance:

56,6

/km

Arcor TNP 03

Conductor:

strand bare copper wire 0,7 mm

Resistance difference:

0,30

/km

Insulation:

PE-Foam skin (02YS)

Insulation resistance:

10

Gkm

a core: YE

Mutual capacitance:

34

nF/km

b core: RD

Capacitance unbalance:

Colour code :

Cable make up:

Screening/sheath:

c core: GN

k1

110

pF/km

d core: BU

k9-12

110

pF/km

cores twisted to quads, quads stranded together in


concentric layers, 2 perforated cores (cross section
0,2 mm), wrapping with tape

ea1/2

1300

pF/km

tinned strand copper wire (cross section 0,2 mm), one


layer aluminium tape, PE-sheath black, reinforced
((L)2YV)

Marking

German Railways
(DB)

PE-foam skin insulated, star quads, with reinforced sheath

Attenuation:
800 Hz
Operating voltage:

0,6

db/km

250

Veff

Near-end crosstalk:

45

dB/abs.

Far-end crosstalk:

45

dB/km

Dielectric strength:

1. line: handset symbol - <meter>

conductor/conductor

500

V/50Hz/1min

2. line: ( >20mm) handset symbol

conductor/shield

2000

V/50Hz/1min

Characteristics of monitoring cores:


Loop resistance:

190

/km

Insulation resistance:
dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

95

/km

Dielectric strength:

Copper wire resistance:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

45

German Railways
PE-foam skin insulated, star-quads, with rodent protection

A-02YS(L)2YB2Y ..x4x0,7mm STI TNP 03

C34
#
0,7

Type

mutual capacitance

number of
double cores

dimension of
conductor

filling

cable elements

overall shield,
armouring

number of
double cores (DC)

A-02YS(L)2YB2Y 3x4x0,7mm
A-02YS(L)2YB2Y 5x4x0,7mm
A-02YS(L)2YB2Y 7x4x0,7mm

6-14

outer diameter
approx. mm

6
10
14

24,0
28,0
30,0

weight
approx. kg/km

500
660
790

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances, with
high resistance against vibrations. The cable is fixed directly at the rail.

Standard:

Arcor TNP 03

Conductor diameter:

0,7

mm

Construction

Loop resistance:

56,6

/km

0,30

/km

Conductor:

strand bare copper wire 0,7 mm

Resistance difference:

Insulation:

PE-Foam skin (02YS)

Insulation resistance:

Colour code :

Cable make up:

Sheath:

a core: YE

L>200m

10

Gkm

b core: RD

100m L 200m

25

Gkm

c core: GN

L<100m

30

Gkm

34

nF/km

k1

110

pF/km

k9-12

110

pF/km

ea1/2

1300

pF/km

d core: BU

Mutual capacitance:

cores twisted to quads, quads stranded together in


concentric layers, 2 perforated cores (0,2 mm), wrapping with tape.

Capacitance unbalance:

tinned copper wire (0,2mm), one layer aluminium


tape, PE-sheath, black ((L)2Y)

Armouring:

one layer of galvanized steel tape (B)

Protective cover:

PE, black (2Y)

Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol

Attenuation:
0,6

db/km

Operating voltage:

800 Hz

250

Veff

Near-end crosstalk:

45

dB abs.

Far-end crosstalk:

45

dB/km

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Dielectric strength:

Characteristics of monitoring cores:


Loop resistance:

190

/km

dry cable

Gkm

drown cable

30

k. abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

95

/km

Insulation resistance:

Dielectric strength:

Copper wire resistance:

46

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-02YS(L)2Y(SR)2Y x4x0,7 mm STI TNP 03

number of
double cores

C34

mutual capacitance

#
0,7

dimension of
copper conductor

filling

cable elements

overall shield,
armouring

6-14

Type

number of
double cores

outer diameter
approx. mm

weight
approx. kg/km

A-02YS(L)2Y(SR)2Y 3x4x0,7 mm STI TNP 03


A-02YS(L)2Y(SR)2Y 5x4x0,7 mm STI TNP 03
A-02YS(L)2Y(SR)2Y 7x4x0,7 mm STI TNP 03

6
10
14

24,0
28,0
30,0

500
660
790

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances, with
high resistance against vibrations. The cable is fixed directly at the rail.

Standard:
Conductor cross section:

0,7

mm

Construction

Loop resistance:

56,6

/km

Arcor TNP 03

Conductor:

strand bare copper wire 0,7 mm

Resistance difference:

0,30

/km

Insulation:

PE-Foam skin (02YS)

Insulation resistance:

10

Gkm

Colour code :

a core: YE

Mutual capacitance:

34

nF/km

b core: RD

Capacitance unbalance:

c core: GN

k1

110

pF/km

d core: BU

k9-12

110

pF/km

cores twisted to quads, quads stranded together in


concentric layers, 2 perforated cores (cross section
0,2 mm), wrapping with tape

ea1/2

1300

pF/km

Attenuation:

Sheath:

tinned strand copper wire (cross section 0,2 mm), one


layer aluminium tape, PE-sheath black ((L)2Y)

0,6

db/km

Operating voltage:

250

Veff

Armouring:

one layer corrugated steel tape ((SR))

Near-end crosstalk:

45

dB/abs.

Protective cover:

PE, black (2Y)

Far-end crosstalk:

45

dB/km

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Cable make up:

Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol

German Railways
(DB)

PE-foam skin insulated, star quads, with rodent protection

800 Hz

Dielectric strength:

Characteristics of monitoring cores:


Loop resistance:

190

/km

Insulation resistance:
dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

95

/km

Dielectric strength:

Copper wire resistance:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

47

German Railways
PE-foam skin insulated, star-quads, with strain relief elements

A-02YS2Y(ST)(ZN)2Y ..x4x0,9mm STI TNP 04

C34

0.9

Type

mutual capacitance

filling

cable elements

overall shield,
armouring

outer diameter
approx. mm

10
14
20
24
32

21,1
22,8
27,1
28,4
31,9

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable for long distances, only
for overground laying and mounting poles.

Standard:

Construction

number of
double cores

dimension of
conductor

number of
double cores

A-02YS2Y(ST)(ZN)2Y 5x4x0,9mm
A-02YS2Y(ST)(ZN)2Y 7x4x0,9mm
A-02YS2Y(ST)(ZN)2Y 10x4x0,9mm
A-02YS2Y(ST)(ZN)2Y 12x4x0,9mm
A-02YS2Y(ST)(ZN)2Y 16x4x0,9mm

10-32

weight
approx. kg/km

354,5
434,1
569,3
660,1
839,8

Arcor TNP 04

Conductor diameter:

0,9

mm

Loop resistance:

56,6

/km

Resistance difference:

0,30

/km

Conductor:

solid bare copper wire 0,9 mm

Insulation:

PE-Foam skin (02YS)

L>200m

10

Gkm

Colour code :

a core: YE

100m L 200m

25

Gkm

b core: RD

L<100m

30

Gkm

34

nF/km

Cable make up:

c core: GN

Mutual capacitance:

d core: BU

Capacitance unbalance:

cores twisted to quads, quads stranded together in


concentric layers, 2 perforated cores ( 0,5 mm),
wrapping with tape.

Sheath:

PE, natural (2Y)

Screening:

tinned copper wire ( 0,4 mm), one layer aluminium


tape ((ST))

Strain relief/
Protective cover:

Insulation resistance:

Glasrovings/ PE, black ((ZN)2Y)

Marking

k1

110

pF/km

k9-12

110

pF/km

ea1/2

1300

pF/km

0,6

db/km

Attenuation:
800 Hz
Operating voltage:

250

Veff

Near-end crosstalk:

45

dB abs.

Far-end crosstalk:

45

dB/km

Dielectric strength:

1. line: handset symbol - <meter>

conductor/conductor

500

V/50Hz/1min

2. line: ( >20mm) handset symbol

conductor/shield

2000

V/50Hz/1min

Characteristics of monitoring cores:


Loop resistance:

190

/km

dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

140

/km

Insulation resistance:

Dielectric strength:

Copper wire resistance:

48

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-02YSF(L)2YV 2x4x1,4 / 2x4x0,9 STI TNP 06

C34 C36

mutual capacitance

0.9

dimension of
conductor

1.4

number of
double cores

A-02YSF(L)2YV 2x4x1,4 / 2x4x0.9

outer diameter
approx. mm

filling

overall shield,
armouring

cable elements

Type

number of
double cores

weight
approx. kg/km

24.0

540

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable, preferable for the
connection of railway connection boxes.
Usable for underground laying and drawing into conduits.

Standard:

Arcor TNP 06

Conductor diameter:

0,9

1,4

mm

Loop resistance:

56,6

23,4

/km

Construction

Resistance difference:

0,30

0,20

/km

Conductor:

solid, bare copper wire 0,9 / 1,4 mm

Insulation:

PE-Foam skin (02YS)

L>200m

10

10

Gkm

Colour code :

a core: YE

100m L 200m

25

25

Gkm

b core: RD

L<100m

30

30

Gkm

34

36

nF/km

Cable make up:

Sheath:

Insulation resistance:

c core: GN

Mutual capacitance:

d core: BU

Capacitance unbalance:

cores twisted to star-quads, quads stranded together


in concentric layers, 2 perforated cores ( 0,5 mm), filled with petrolat (F), wrapping with tape, wrapping
with swellable tape
aluminium laminated, reinforced PE-sheath, black
((L)2YV)

German Railways
(DB)

PE-foam skin insulated, star-quads, with reinforced sheath

k1

110

110

pF/km

k9-12

110

110

pF/km

ea1/2

1300

1300

pF/km
db/km

Attenuation:
800 Hz

0,6

0,4

Operating voltage:

250

250

Marking

Veff

Near-end crosstalk:

45

45

dB abs.

1. line: handset symbol - <meter>

Far-end crosstalk:

45

45

dB/km

2. line: ( >20mm) handset symbol

Dielectric strength:
conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Characteristics of monitoring cores:


Loop resistance:

190

/km

Insulation resistance:
dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Dielectric strength:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

49

German Railways
PE-foam skin insulated, star-quads, with rodent protection

A-02YSF(L)2Y(SR)2Y 3x4x0,9mm STI TNP 06

C34

0.9

mutual capacitance

number of
double cores

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

number of
double cores (DC)

A-02YSF(L)2Y(SR)2Y

3x4x0,9mm

outer diameter
approx. mm

20,0

weight
approx. kg/km

350

Application

Technical Details (at 20C)

The cable is designed for use as railway signalling cable, preferable for theconnection of railway connection boxes. Useable for underground laying and
drawing into conduits.

Standard:

Arcor TNP 06

Conductor diameter:

0,9

mm

Loop resistance:

56,6

/km

Construction

Resistance difference:

0,30

/km

Conductor:

solid bare copper wire 0,9 mm

Insulation:

PE-Foam skin (02YS)

L>200m

10

Gkm

Colour code :

a core: YE

100m L 200m

25

Gkm

b core: RD

L<100m

30

Gkm

34

nF/km

k1

110

pF/km

k9-12

110

pF/km

ea1/2

1300

pF/km

Cable make up:

Sheath:

Insulation resistance:

c core: GN

Mutual capacitance:

d core: BU

Capacitance unbalance:

cores twisted to quads, quads stranded together in


concentric layers, 2 perforated cores ( 0,5 mm), filled
with petrolat (F), wrapping with tape, wrapping with
swellable tape
aluminium laminated PE-sheath, black ((L)2Y)

Attenuation:
0,6

db/km

Operating voltage:

250

Veff

Near-end crosstalk:

45

dB abs.

Marking

Far-end crosstalk:

45

dB/km

1. line: handset symbol - <meter>

Dielectric strength:
conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Armouring:

one layer of corrugated steel tape ((SR))

Protective cover:

PE, black (2Y)

2. line: ( >20mm) handset symbol

800 Hz

Characteristics of monitoring cores:


Loop resistance:

190

/km

Insulation resistance:
dry cable

Gkm

drown cable

30

k abs.

conductor/conductor

500

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

Dielectric strength:

50

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-2Y(L)2YB2Y 1x4x

mutual capacitance

1,4

dimension of
copper conductor

1,53

number of
double cores

filling

overall shield,
armouring

cable elements

Type

number of
double cores

outer diameter
approx. mm

weight
approx. kg/km

A-2Y(L)2YB2Y 1x4x1,4
A-2Y(L)2YB2Y 1x4x1,53

2
2

14,0
18,0

260
350

Application

Technical Details (at 20C)

The cable is designed for use in signal systems (unless the application of special cables of signaltechnique is required), preferably for transmission of alternating currents in systems which needs a high symmetry against each other.

Standard:

DB AG 416.0120

Conductor diameter:

1,4

1,53

mm

Loop resistance:

23,4

19,8

/km

Construction

Insulation resistance:

10
52

43

nF/km

k1

650

240

pF/km

ea1/2

1300

650

pF/km

Conductor:

solid, bare copper wire 1,4 / 1,53 mm

Mutual capacitance:

Insulation:

PE (2Y)

Capacitance unbalance:

Colour code :

a core: transparent
b core: transparent with one ring mark every 17 mm
c core: transparent with two ring marks every 34 mm

Operating voltage:

Gkm

d core: transparent with two ring marks every 17 mm

DC

600

600

Cable make up:

cores twisted to a quad, wrapping with tape

AC

420

420

V/100 Hz

Screening:

one copper wire ( 0,4mm), aluminium laminated PEsheath, black ((L)2Y),

Near-end crosstalk:

55

60

dB

4,2

dB/km

120+/-10%

120+/-10%

Armouring:

one layer steel tape, galvanized (B)

Protective cover:

PE, black (2Y)

Marking
SIGNAL / Eurobalise (alternating every 25 cm) - type - VDE reg. nr. - PENGG
KABEL - <meter>

German Railways
(DB)

PE insulated, star-quads, with rodent protection

Attenuation:
560 kHz
Impedance:
200 - 600 kHz
Dielectric strength:
conductor/conductor

2500

2500

V/50Hz/1min

conductor/shield

2500

2500

V/50Hz/1min

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

51

German Railways
PE-insulated, star-quads, with inductive protection

AJ-2Y(L)2YDB2Y 1x4x1,53

C43

1.53

Type

number of
double cores

AJ-2Y(L)2YDB2Y 1x4x1,53
AJ-2Y(L)2YDB2Y 1x4x1,53
AJ-2Y(L)2YDB2Y 1x4x1,53

2
2
2

mutual capacitance

number of
double cores

dimension of
conductor

filling

cable elements

overall shield,
armouring

index of inductiveprotection rk (f=16 2/3 Hz)

600
500
400

outer diameter
approx. mm

22,0
22,0
24,0

weight
approx. kg/km

740
830
1330

Application

Technical Details (at 20C)

The cable is designed for use in signal systems (unless the application of special cables of signaltechnique is required), preferably for transmission of alternating currents in systems which needs a high symmetry against each other.

Standard:

DB AG 416.0120

Conductor diameter:

1,53

mm

Loop resistance:

Construction

19,8

/km

Insulation resistance:

10

Gkm

43

nF/km

k1

240

pF/km

ea1/2

650

pF/km

Conductor:

solid, bare copper wire 1,53 mm

Mutual capacitance:

Insulation:

PE (2Y)

Capacitance unbalance:

Colour code :

a core: transparent
b core: transparent with one ring mark every 17 mm
c core: transparent with two ring marks every 34 mm

Operating voltage:

d core: transparent with two ring marks every 17 mm

DC

cores twisted to a quad, wrapping with tape

600

Cable make up:

AC

V/100 Hz

1st Screening:

one copper wire ( 0,4mm), aluminium laminated PEsheath, black ((L)2Y)

420
60

dB

8,8 kHz

0,8

dB/km

280 kHz

3,0

dB/km

560 kHz

4,2

dB/km

1,8 MHz

8,0

dB/km

8,8 kHz

147+/-15%

200 - 600 kHz

120+/-10%

1,8 MHz

120+/-10%

2nd Screening:

one layer copper wires, wrapping with tape (D)

Armouring:

two layer steel tape, galvanized (B)

Protective cover:

PE, black (2Y)

Marking
SIGNAL / Eurobalise (alternating every 25 cm) - type - VDE reg. nr. - PENGG
KABEL - <meter>

Near-end crosstalk (1 MHz):


Attenuation:

Impedance:

Reduction factor:

acc. to DB AG 416.0120

Temperature range

52

during operation

-40 up to +60

during installation

-10 up to +60

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
A-2YF(L)2Y ..x4x0,4 STIII BD

C50

0.4

mutual capacitance

6200

number of
double cores

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y

number of
double cores

6x2x0.4
10x2x0.4
20x2x0.4
30x2x0.4
40x2x0.4
50x2x0.4
70x2x0.4
100x2x0.4
150x2x0.4
200x2x0.4

STIII
STIII
STIII
STIII
STIII
STIII
STIII
STIII
STIII
STIII

BD
BD
BD
BD
BD
BD
BD
BD
BD
BD

outer diameter
approx. mm

6
10
20
30
40
50
70
100
150
200

9.5
10.5
12.5
15.0
16.5
17.5
20.0
23.0
27.5
31.0

weight
approx. kg/km

80
105
160
230
285
340
445
600
910
1165

Application

Technical Details (at 20C)

The cable is designed for transmission of railway station signals. Usable for
underground laying and drawing into conduits.

Standard:
Conductor diameter:

0,4

mm

Construction

Conductor loop resistance:

300

/km

Gkm

Dlk 1.013.151

Conductor:

solid, bare copper wire 0,4 mm

Insulation resistance:

Insulation:

PE (2Y)

Mutual capacitance (800Hz):

Colour code :

a core: transparent

100%

50

nF/km

b core: transparent with one ring mark every 17 mm

95%

48

nF/km

c core: transparent with two ring marks every 34 mm


Cable make up:

Capacitance unbalance:

d core: transparent with two ring marks every 17 mm

k1

100%

800

pF/300m

cores twisted to quads, quads stranded together in


concentric layer, filled with petrolat (F), wrapping with
tape

k1

98%

400

pF/300m

k9-12 100%

300

pF/300m

k9-12 98%

100

pF/300m

1,49

dB/km

2000

V/50Hz/2min

Sheath:

aluminium laminated PE-sheath, black ((L)2Y)

Cable short mark:

star-quad stranding (STIII)


bundle stranding (BD)

German Railways
(DB)

PE-insulated, star-quads, reinforced sheath

Attenuation:
800 Hz
Dielectric strength:
conductor/shield

Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

53

German Railways
PE-foam skin insulated, star-quads

A-02YSF(L)2Y ..x2x.. STIII BD

C42 C42

0.8

0.6

mutual capacity

6200

number of
double cores

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y

6x2x..
10x2x..
20x2x..
30x4x..
40x4x..
50x4x..
70x4x..
100x4x..
200x4x..

conductor diameter 0.6 mm

conductor diameter 0.8 mm

number of
double cores

outer diameter
approx mm

weight
approx. kg/km

outer diameter
approx. mm

weight
approx. kg/km

6
10
20
30
40
50
70
100
200

10,3
11,8
15,3
17,6
19,6
21,3
24,8
28,6
39,2

107,5
147,3
255,2
350,6
443,2
532,1
730,2
991,7
1876,5

13,2
15,3
20,0
22,7
25,4
28,2
32,3
38,8
51,8

176,9
252,0
450,3
601,6
755,1
952,6
1273,9
1823,4
3301,0

Application

Technical Details (at 20C)

The cable is designed for transmission of railway station signals. Usable for
underground laying and drawing into conduits.

Standard:

Dlk 1.013.151

Conductor diameter:

0,6

0,8

mm

Construction

Conductor loop resistance:

130

73,2

/km

Gkm

Conductor:

solid, bare copper wire

Insulation resistance:

Insulation:

PE - foam skin (02YS)

Mutual capacitance (800Hz):

Colour code :

a core: transparent

100%

42

42

nF/km

b core: transparent with one ring mark every 17 mm

95%

40

40

nF/km

c core: transparent with two ring marks every 34 mm

80%

38

38

nF/km

k1

100%

800

800

pF/300m

98%

400

400

pF/300m

k9-12 100%

300

300

pF/300m

k9-12 98%

100

100

pF/300m

0,91

0,69

dB/km

d core: transparent with two ring marks every 17 mm


Cable make up:

Sheath:
Cable short mark:

cores twisted to quads, quads stranded together in


concentric layers, filled with petrolat (F), wrapping with
tape
aluminium laminated PE-sheath, black ((L)2Y)
star-quad stranding (STIII)
bundle stranding (BD)

Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol

54

Capacitance unbalance:

Attenuation:
800 Hz
Dielectric strength
conductor/conductor

500

500

V/50Hz/2min

conductor/shield

200

2000

V/50Hz/2min

Operating peak voltage:

225

225

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

German Railways
AJ-02YSF(L)2YDB2Y ..x2x0,8 STIII BD

C42

0,8

mutual capacitance

6200

number of
double cores

dimension of
copper conductor

filling

overall shield,
armouring

cable elements

Type

number of
double cores

AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y

10x2x0.8 STIII BD
20x2x0.8 STIII BD
30x2x0.8 STIII BD
40x2x0.8 STIII BD
50x2x0.8 STIII BD
70x2x0.8 STIII BD
100x2x0.8 STIII BD
200x2x0.8 STIII BD

outer diameter
approx. mm

10
20
30
40
50
70
100
200

24,2
29,1
31,9
35,3
38,7
45,0
50,2
66,3

weight
approx. kg/km

1070,8
1486,0
1821,7
2203,5
2525,8
3626,5
4517,7
6985,5

Application

Technical Details (at 20C)

The cable is designed for transmission of railway station signals. Usable for
underground laying and drawing into conduits.

Standard:

Dlk 1.013.151

Conductor diameter:

0,8

mm

Construction

Conductor loop resistance:

73,2

/km

Gkm

Conductor:

solid, bare copper wire

Insulation resistance:

Insulation:

PE - foam skin (02YS)

Mutual capacitance (800Hz):

Colour code :

a core : transparent

100%

42

nF/km

b core : transparent with one ring mark every 17 mm

95%

40

nF/km

c core : transparent with two ring marks every 34 mm

80%

38

nF/km

d core : transparent with two ring marks every 17 mm

Capacitance unbalance

cores twisted to quads, quads stranded together in


concentric layers, filled with petrolat (F), wrapping with
tape

k1

100%

800

pF/300m

k1

98%

400

pF/300m

aluminium laminated PE-sheath, black ((L)2Y)

300

pF/300m

Sheath:

k9-12 100%

one layer copper wires (D), wrapping with tape

100

pF/300m

Screening:

k9-12 98%

Armouring:

two layers of steel tape (B)


PE, black (2Y)

0,69

dB/km

Protective Cover:

conductor/conductor

500

V/50Hz/2min

Cable short mark:

star-quad stranding (STIII)

conductor/shield

2000

V/50Hz/2min

Operating peak voltage:

225

Reduction factor:

acc. Dlk 1.013.151 and Dlk 1.01.104

Cable make up:

bundle stranding (BD)

German Railways
(DB)

PE-foam skin insulated, star-quads, with inductive protection

Attenuation:
800 Hz
Dielectric strength

Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

55

German Railways
Note

56

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

French Railways, SNCF


page 58

MD4 x4x0,8

page 59

ZPFU- ...px1

page 60

ZUG-S ...P...

page 61

ZUT-S ...P...

page 62

4D...

page 63

French Railways
(SNCF)

ZPAU -px

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

57

French Railways
PE insulated, pairs, with inductive protection

ZPAU -px
mutual capacity

#
2,5

#
1

1-56

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

number of
double cores

ZPAU 1px2,5
ZPAU 4px1
ZPAU 7px1
ZPAU 14px1
ZPAU 21px1
ZPAU 28px1
ZPAU 56px1

outer diameter
approx. mm

1
4
7
14
21
28
56

Application
The cable is designed for the connection of the control center to the equipment shelters.
Construction
Conductor:

solid, bare copper wire

Insulation:

PE

Colour code:

a core: transparent
b core: BK - BE - YE - RD - GN

763
620
944
1384
1731
2122
3290

Technical Details (at 20C)


Standard:

SNCF CT 445

Conductor cross section:

2,5

mm

Conductor resistance:

18,1

7,41

/km

Insulation resistance:

Gkm

Mutual capacitance:
1000 (+/-200) Hz

nF/km

55

8,9 kHz

45

nF/km

300

pF/500m

Capacitance unbalance:

200

Reduction factor:

according to SNCF CT 445

cores twisted to pairs., pairs stranded together to the


cable core, wrapping with tape

Sheath:

PE, transparent

Screening:

one layer copper tape; PE transparent

45 kHz

Armouring:

two layers steel tape

560 kHz

Protective cover:

PE, black

Attenuation:
dB/km

2,5
3,8

dB/km

Impedance:
800Hz

58

weight
approx. kg/km

21,2
23,8
26,7
31,0
35,5
39,5
49,5

Cable make up:

Marking
type - CT 445 - PENGG KABEL - month/year of production - <meter> RESEAU FERRE DE FRANCE

number of
double cores

120+/-10

8,9 kHz

130+/-10

Dielectric strength:
conductor/conductor

3000

V/DC/3min

conductor/shield

3000

V/DC/3min

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

French Railways
PE-foam skin insulated, star quads, with inductive protection
mutual capacity

0.8

14-56

dimension of
conductor

MD4
MD4
MD4
MD4

number of
double cores

7x4x0,8
14x4x0,8
21x4x0,8
28x4x0,8

outer diameter
approx. mm

14
28
42
56

Application
The cable is designed for long distance telecommunications alongside railway
lines.
Construction
Conductor:

solid, bare copper wire 0,8 mm

Insulation:

PE-foam skin

Colour code:

a core: GY - OG
b core: WH - YE - BK - GN - BU - BN - RD
c core: VT

23,7
28,5
33,3
34,0

Sheath:

SNCF TL DCG N 2328 Ed.04

Conductor diameter:

0,8

mm

Conductor resistance:

35,6

/km

Insulation resistance:

15

Gkm

Mutual capacitance (at f=800Hz):

49

nF/km

max

51

nF/km

min

46

nF/km

50

pF/1450m

max

340

pF/1450m

30

pF/1450m

340

pF/1450m

200

pF/1450m

1025

pF/1450m

Capacitance unbalance:
k1

k9-12

petrol jelly, one tinnend copper wire, wrapping with


tape; PE transparent

ea1/2

two layers steel tape, wrapping with tape

Protective cover:

PE, black

Marking
<meter> - "RFF" - type - "2328" - "ed4"- PENGG KABEL - year of production

773
1277
1787
1913

Technical Details (at 20C)

cores twisted to pairs, pairs cabled together to a bundel, bundels stranded to the cable core, wrapping with
tape

Armouring:

weight
approx. kg/km

Standard:

d core: BU - BN - RD - WH - YE - BK - GN
Cable make up:

filling

overall shield,
armouring

cable elements

Type

number of
double cores

French Railways
(SNCF)

C49

MD4 x4x0,8

max
max
Reduction factor:

acc. to SNCF TL DCG N 2328 Ed.04

Attenuation:
1MHz

15,9

dB/km

520+/-10%

/km

conductor/conductor

1500

V/DC/1min

conductor/shield

3000

V/DC/1min

conductor/shield

3750

V/DC/3sek

Impedance:
800Hz
Dielectric strength:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

59

French Railways
PE insulated, pairs, with armouring

ZPFU -px1
C 55
#
1

Type

Construction
Conductor:

solid, bare copper wire

Insulation:

PE

Colour code:

a core: transparent
b core: BK - BE - YE - RD - GN

Sheath:

cores twisted to pairs, pairs stranded together to the


cable core, wrapping with tape
PE, transparent

Armouring:

two layers steel tape, wrapping with tape

Protective cover:

PE, black

Marking
type - CT 445 - PENGG KABEL - month/year of production - <meter> - PROPRIETE RFF

60

number of
double cores

filling

cable elements

overall shield,
armouring

outer diameter
approx. mm

1
2
4
7
14
21
28
56

Application
The cable is designed for the connection of the control center to the equipment shelters.

1-56

dimension of
conductor

number of
double cores

ZPFU 1px1
ZPFU 1px1
ZPFU 4px1
ZPFU 7px1
ZPFU 14px1
ZPFU 21px1
ZPFU 28px1
ZPFU 56px1

Cable make up:

mutual capacity

12,5
13,6
17,3
20,8
27,0
29,9
33,4
43,8

weight
approx. kg/km

186
248
369
695
1083
1363
1668
2752

Technical Details (at 20C)


Standard:

SNCF CT 445

Conductor cross section:

mm

Conductor resistance:

18,1

/km

Insulation resistance:

Gkm

55

nF/km

200

pF/500m

2,5

dB/km

120+/-10

conductor/conductor

3000

V/DC/3min

conductor/shield

3000

V/DC/3min

Mutual capacitance:
1000 (+/-200) Hz
Capacitance unbalance:
Attenuation:
45 kHz
Impedance:
800Hz
Dielectric strength:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

French Railways
PVC insulated, pair stranded

ZUG-S P
mutual capacity

#
1

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

ZUG-S
ZUG-S
ZUG-S
ZUG-S
ZUG-S

number of
double cores

1P1
3P1
6P1
12P1
28P0,38

Application
The cable is designed for connection of railway network equipments in the
traffic control center.
Construction
Conductor:

strand tinned copper wire

Insulation:

PVC

Colour code:

outer diameter
approx. mm

1
3
6
12
28

number of
double cores

weight
approx. kg/km

6,8
9,4
12,3
15,9
15,7

58
113
201
357
335

Technical Details (at 20C)


Standard:

SNCF CT 455

Conductor cross section:

0,38

mm

Loop resistance:

20,1

52,5

/km

2500

2500

V/50Hz/3min

French Railways
(SNCF)

#
0,38

1-12

Dielectric strength:
conductor/conductor

a core: WH
b core: BK - BU - YE -BN - RD - GN

Cable make up:

cores twisted to pairs, pairs stranded together to the


cable core, wrapping with tape

Sheath:

PVC, black

Marking
type - CT 455 - PENGG KABEL - month and year of production - <meter>

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

61

French Railways
PVC insulated, star-quad, with inductive protection

ZUT-S P

mutual capacity

#
1

Type

Construction
Conductor:

strand tinned copper wire

Insulation:

PVC

Colour code:

filling

cable elements

overall shield,
armouring

outer diameter
approx. mm

2
6
12

Application
The cable is designed for connection of railway network equipments in the
traffic control center.

number of
double cores

dimension of
conductor

number of
double cores

ZUT-S 2P1
ZUT-S 6P1
ZUT-S 12P1

2-12

8,2
14,0
18,0

weight
approx. kg/km

134
280
445

Technical Details (at 20C)


Standard:

SNCF CT 455

Conductor cross section:

mm

Loop resistance:

52,5

/km

2500

V/50Hz/3min

Dielectric strength:
conductor/conductor

a core: WH
b core: BK
c core: YE
d core: BU

Cable make up:

cores twisted to a quad, wrapping with tape

Screening:

tinned copper netting (8x0,2mm), wrapping with tape

Sheath:

PVC, black

Marking
type - CT 455 - PENGG KABEL - month and year of production - <meter>

62

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

French Railways
PE insulated, star quads, with rodent protection

4D

0.8

mutual capacity

8-28

dimension of
conductor

number of
double cores

4D4
4D8
4 D 14

outer diameter
approx. mm

8
16
28

Application
The cable is designed for long distance telecommunications alongside railway
lines.
Construction
Conductor:

solid, bare copper wire 0,8 mm

Insulation:

PE

Colour code:

a core: GY - OG
b core: WH - YE - BK - GN - BU - BN - RD
c core: VT

SNCF CT AFT N 2329 Ed.0

Conductor diameter:

0,8

Conductor resistance:

36,7

/km

Insulation resistance:

15

Gkm

Mutual capacitance (at f=800Hz): 50

nF/km

max: 54

nF/km

min:

46

nF/km

40

pF/300m

max

200

pF/300m

15

pF/300m

k1

k9-12

Sheath:

filled with petrolat, wrapping with tape, one tinnend


copper wire, wrapping with tape; PE, transparent

ea1/2

PE, black

Marking
<meter> - "SNCF" - type - "2329" - "ed0"- PENGG KABEL - year of production

mm

Capacitance unbalance:

cores twisted to quads, quads stranded together to


concentric layers

Protective cover:

402
572
821

Technical Details (at 20C)


Standard:

Cable make up:

two layers steel tape, filled with petrolat, wrapping with


tape

weight
approx. kg/km

17,0
19,9
23,6

d core: BU - BN - RD - WH - YE - BK - GN

Armouring:

filling

overall shield,
armouring

cable elements

Type

number of
double cores

French Railways
(SNCF)

C50

max

75

pF/300m

130

pF/300m

1600

pF/300m

conductor/conductor

1500

V/DC/1min

conductor/shield

3000

V/DC/1min

conductor/shield

3750

V/DC/3sek

max
Dielectric strength:

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

63

French Railways
Note

64

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Swiss Railways, SBB


page 66

Sw-Kabel ...x4x... CLT

page 67

PE-ALT-CLT 1x4x1,53

page 68

Swiss Railways
(SBB)

PE4-ALT-CLT ...x4x...

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

65

Swiss Railways
Foam-skin PE insulated, star-quads, with rodent protection
C40

0,8

PE4-ALT-CLT ...x4x

mutual capacity

1,0

2-200

dimension of
conductor

filling

overall shield,
armouring

cable elements

Type

PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT

number of
double cores

1x4x..
3x4x..
5x4x..
10x4x..
20x4x..
30x4x..
50x4x..

conductor diameter 0,8 mm

conductor diameter 1,0 mm

outer diameter
approx. mm

outer diameter
approx. mm

2
6
10
20
40
60
100

Application
The cable is desigend for general use in railway telecommunication systems.
Construction
Conductor:

solid, bare copper wire 0,8 / 1,0 mm

Insulation:

foam-skin PE (PE4)

Colour code :

a core: WH
b core: OG - GN - BN - GY

weight
approx. kg/km

14,6
18,5
21,8
23,0
28,8
31,1
37,4

200
340
440
635
974
1224
1790

Sheath:

one or two drain wires; aluminium laminated PEsheath, black (ALT)

Armouring:

two layers galvanized steel tape (CL)

Protective cover:

PE, black (T)

Marking
PENGG KABEL - year of procution - type - order number - "=>" (arrow from
the red end) - <meter>

66

541
923
1241
1872
2250

Technical Details (at 20C)


SBB I-PS 3001.52.1000

Conductor diameter:

0,8

1,0

mm

Loop resistance:

73,5

47,0

/km

Insulation resistance:

10

10

Gkm

Mutual capacitance:

40

40

nF/km

100%

380

380

pF/km

abs

65

65

pF/km

200

200

pF/km

35

35

pF/km

Capacitance unbalance:
k1

d core: VT
cores twisted to quads, quads stranded together in
concentric layer, wrapping with tape

20,8
26,3
30,8
36,7
53,5

weight
approx. kg/km

Standard:

c core: TQ
Cable make up:

number of
double cores

k9-12
abs
ea1/2

640
abs

100

640
100

pF/km
pF/km

Dielectric strength:
conductor/conductor

2000

V/50Hz/1min

conductor/shield

2000

V/50Hz/1min

-5 to +50

Temperatur range:
during installation

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Swiss Railways
PE insulated, star-quads, with rodent protection

Sw-Kabel x4x CLT

mutual capacity

1,5

2,2

2-60

dimension of
conductor

filling

overall shield,
armouring

cable elements

Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel

number of
double cores

1x4x... CLT
3x4x... CLT
5x4x... CLT
10x4x... CLT
15x4x... CLT
20x4x... CLT
25x4x... CLT
30x4x... CLT

conductor diameter 1,5 mm

conductor diameter 2,2 mm

outer diameter
approx. mm

outer diameter
approx. mm

2
6
10
20
30
40
50
60

Application
The cable is designed for general use in protection systems with an operating
voltage 500 Veff (16 2/3 Hz) or 800 V DC.
Construction
Conductor:

solid, bare copper wire 1,5 / 2,2 mm

Insulation:

PE

Colour code :

a core: WH

weight
approx. kg/km

15,5
23,5
28,5
36,0
41,0
46,5
52,5
55,0

223
558
785
1388
1946
2533
3150
3557

Technical Details (at 20C)


SBB I-PS 3001.82.1000

Conductor diameter:

1,5

2,2

mm

Loop resistance:

20,9

10,0

/km

Insulation resistance:

10

10

Gkm

Mutual capacitance:

52

60

nF/km

k1

400

400

pF/km

k9-12

400

400

pF/km

ea1/2

650

650

pF/km

Capacitance unbalance:

c core: TQ
Cable make up:

cores twisted to quads, quads stranded together in


concentric layers, wrapping with tape

Sheath:

PE, black

Armouring:

two layers galvanized steel tape (CL)

Protective cover:

PE, black (T)

342
930
1380
2560
3630
4780
5850
6363

Standard:

b core: OR - GN - BN - GY
d core: VT

16,5
28,0
33,5
44,5
51,5
58,5
66,5
68,0

weight
approx. kg/km

Swiss Railways
(SBB)

Type

number of
double cores

Dielectric strength:
conductor/conductor

2000

V/50Hz/1min

conductor/shield

4000

V/50Hz/1min

Marking
SIGNAL - "=>" (arrow from the red end) - PENGG KABEL - year of production - order number - <meter>

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

67

Swiss Railways
PE insulated, star-quads, with inductive protection

PE-ALT-CLT 1x4x1,53mm
C42

1,53

Type

Construction
Conductor:

solid, bare copper wire 1,53 mm

Insulation:

PE (PE)
a core: WH

cable elements

overall shield,
armouring

outer diameter
approx. mm

15,2

d core: VT
Cable make up:

cores twisted to a quad, wrapping with tape

Sheath:

two drain wires; aluminium laminated PE-sheath, black


(ALT)

Armouring:

two layers galvanized steel tape (CL)

Protective cover:

PE, black (T)

Marking
SIGNAL - PENGG KABEL - year of prodcution - type - order number - <meter>

weight
approx. kg/km

292

Technical Details (at 20C)


Standard:

SBB I-PS 3001.52.2000

Conductor diameter:

1,53

mm

Loop resistance:

19,8

/km

Insulation resistance:

10

Gkm

max

48,6

nF/km

min

35,9

nF/km

0,8

dB/100m

120+/-5%

k1

240

pF/km

ea1/2

640

pF/km

conductor/conductor

2500

V/50Hz/1min

conductor/shield

2500

V/50Hz/1min

-5 to +50

Mutual capacitance:

b core: OR
c core: TQ

number of
double cores

filling

Application
The cable is designed for the connection of ETCS-Balisen.

dimension of
conductor

number of
double cores

PE-ALT-CLT 1x4x1,53

Colour code :

mutual capacity

Attenuation:
1,8 MHz
Impedance:
1,8 MHz
Capacitance unbalance:

Dielectric strength:

Temperature range:
during installation

68

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Hungarian Railways, MAV


page 70

AJ-2Y(L)2YLB2Y ...x... (BRQA)

page 71

Hungarian
Railways
(SBB)

AJ-02YSF(L)2YD2Y ...x4x0,8 (HvrQ)

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

69

Hungarian Railway Cables


PE-foam skin insulated, star quads, with inductive protection AJ-02YSF(L)2YD2Y x4x0,8 (HvrQ)
C42

mutual capacity

2-200

dimension of
conductor

0,8

number of
double cores

AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y

1x4x0,8 (HvrQ)
5x4x0,8 (HvrQ)
10x4x0,8 (HvrQ)
15x4x0,8 (HvrQ)
25x4x0,8 (HvrQ)
50x4x0,8 (HvrQ)
75x4x0,8 (HvrQ)
100x4x0,8 (HvrQ)

Construction
Conductor:

solid, bare copper wire 0,8 mm

Insulation:

PE foam skin (02YS)

Colour code :

outer diameter
approx. mm

2
10
20
30
50
100
150
200

Application
The cable is designed for underground laying and drawing into conduits for
local networks.

a core: RD - GN - YE - BU - BN

15,0
21,0
27,0
29,0
36,0
45,0
54,0
61,0

costumer specification MAV P-2518/2002

Conductor diameter:

0,8

mm

Loop resistance:

73,2

/km

Insulation resistance:

Gkm

Mutual capacitance:

42

nF/km

100%

800

pF/300m

50%

400

pF/300m

300

pF/300m

400

pF/300m

800

pF/300m

conductor/conductor

500

V/50Hz/2min

conductor/shield

2000

V/50Hz/2min

during installation:

-5 to +70

during operation:

-30 to +70

Capacitance unbalance:
k1

k9-12 100%

d core: GY

for cables 75 quads, 5 basic strands cabeld together


to primary strands and cabeld together in concentric
layers
Filling:

filled with petrol jelly (F), wrapping with tape

Sheath:

aluminium laminated PE-sheath, black ((L)2Y)

Screening:

1 layer copper wires ( 1,4 mm) (D), wrapping with tape

Protective cover:

PE, black (2Y)

350
690
1040
1210
1630
2510
3520
4420

Technical Details (at 20C)

c core: BK
cores twisted to quads, 5 quads cabled together to
basic strands, basic strands cabeld together in
concentric layer (50 quads);

weight
approx. kg/km

Standard:

b core: WT

Cable make up:

filling

overall shield,
armouring

cable elements

Type

number of
double cores

50%
ea1/2 100%
Dielectric strength:

Temperature range:

Marking
MV ZRt. - handset symbol - <meter> - type - PENGG KABEL - year of procution - CE - order number

70

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Hungarian Railway Cables


PE-insulated, single core, with rodent protection

AJ-2Y(L)2YLB2Y x (BRQA)

mutual capacity

1,0

1,5

2-91

dimension of
conductor

filling

overall shield,
armouring

cable elements

number of
cores

AJ-2Y(L)2YLB2Y 2x...
AJ-2Y(L)2YLB2Y 4x...
AJ-2Y(L)2YLB2Y 7x...
AJ-2Y(L)2YLB2Y 10x...
AJ-2Y(L)2YLB2Y 14x...
AJ-2Y(L)2YLB2Y 21x...
AJ-2Y(L)2YLB2Y 30x...
AJ-2Y(L)2YLB2Y 37x...
AJ-2Y(L)2YLB2Y 48x...
AJ-2Y(L)2YLB2Y 61x...
AJ-2Y(L)2YLB2Y 75x...
AJ-2Y(L)2YLB2Y 91x...

2
4
7
10
14
21
30
37
48
61
75
91

Application
The cable is designed for connection of Station signal-safty equipments.
Cables can be burried directly into ground or can be laid in cable ducts, tubes
and indoor.
Construction

conductor diameter 1,0 mm

conductor diameter 1,5 m

outer diameter
approx. mm

outer diameter
approx. mm

weight
approx. kg/km

12,0
15,5
16,8
18,7
19,5
21,5
24,5
25,6
27,8
29,4
31,6
33,3

250
362
432
515
590
821
1023
1129
1322
1507
1726
1944

14,2
17,1
18,6
21,1
22,1
25,6
28,3
29,8
32,7
35,2
38,1
40,2

weight
approx. kg/km
310
443
547
676
782
1170
1451
1645
1943
2338
2709
3099

Technical Details (at 20C)


Standard:

P-12440/2002 + techn. Changes 19.12.06

Conductor diameter:

1,0

1,5

mm

Conductor resistance:

23,39

10,03

/km

Insulation resistance:

10

10

Gkm

P-12440/2002 + techn. Changes 19.12.06

Conductor:

solid, bare copper wire 1,0 / 1,5 mm

Reduction factor:

Insulation:

PE (2Y)

Dielectric strength:

Colour code :

beginning core: red

conductor/conductor

2000

V/50Hz/2min

pilot core: blue

conductor/screening

2000

V/50Hz/2min

other cores: nature or black


Cable make up:

cores are stranded in concentric layers; neighbouring layers must be stranded in opposite direction, wrapping with
tape

Sheath:

aluminium laminated PE-sheath, black ((L)2Y)

Screening:

one layer aluminium tape (L)

Armouring:

two layer galvanized steel tape (B)

Hungarian
Railways
(SBB)

Type

number of
cores

Protective cover: PE, black (2Y)


Marking
PENGG KABEL - year of production - type - MAV Zrt. - <meter> - CE - order
number

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

71

Hungarian Railway Cables


Note

72

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Slovenian Railways, SZ
page 74

Slovenian
Railways
(SZ)

SPZ ...x...

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

73

Slovenian Railways
PVC insulated, single core, with rodent protection

SPZ x
mutual capacity

0,9

1,4

2-133

dimension of
conductor

number of cores

filling

overall shield,
armouring

cable elements

conductor diameter 0,9 mm

conductor diameter 1.4 mm

Type

number of
cores

outer diameter
approx mm

weight
approx. kg/km

outer diameter
approx. mm

weight
approx. kg/km

SPZ 4 x ...
SPZ 5 x ...
SPZ 8 x ...
SPZ 10 x ...
SPZ 12 x ...
SPZ 16 x ...
SPZ 21 x ...
SPZ 24 x ...
SPZ 27 x ...
SPZ 33 x ...
SPZ 40 x ...
SPZ 48 x ...
SPZ 61 x ...
SPZ 80 x ...
SPZ 108 x ...
SPZ 133 x ...

4
5
8
10
12
16
21
24
27
33
40
48
61
80
108
133

12,0
12,2
13,1
14,6
14,9
16,0
16,8
18,4
19,5
19,8
22,1
23,7
25,3
28,0
31,7
35,1

210
218
256
326
350
408
471
530
611
639
794
898
1054
1282
1636
2028

13,9
14,6
15,9
17,4
17,8
20,1
20,4
24,2
24,6
26,0
27,0
30,2
32,4
35,7
41,8
45,6

294
322
402
488
535
691
771
965
1032
1180
1263
1592
1896
2305
3116
3799

Application

Technical Details (at 20C)

The cable is designed for connection of Station signal-safety equipments on


electrified main railways single-phase system of 25 kV, 50 Hz and D.C. system
of 3 kV.
Cables can be burried directly into ground or can be laid in cable ducts,
tubes and indoor.
Conctructions with different Number of wires are also allowed in acc. to agreement with producer and buyer.

Standard:

JZS S2.011 / 2009

Conductor diameter:

0,9

1,4

mm

Conductor resistance:

28,9

11,9

/km

Insulation resistance:

km

Mutual capacitance:

180

210

nF/km

Dielectric strength (cond./cond.) 2000

2000

V/50Hz/1min

Construction
Conductor:

solid, bare copper wire 0,9 / 1,4 mm

Insulation:

PVC (P)

Colour code :

starting wire in outer layer :

red

starting wire in other layers :

blue

all other wires:

grey

Cable make up:

cores are stranded in concentric layers; Neighbouring


layers must be stranded in opposite direction, wrapping
with tape

Sheath:

PVC, black

Armouring:

one layer galvanized steel tape (Z)

Protective cover:

PVC, black

Temperature range:
during installation

-5 to +70

during operation

up to +60

Marking
<meter> - type- JZS S2.011 - PENGG KABEL

74

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Optic Cables


page 76

A-DF(ZN)2Y4Y

page 78

A-DF(ZN)2Y(SR)2Y

page 80

A-DQ(ZN)2Y(HD) ADSS 6kN

page 82

A-D2Y(ZN)2Y ADSS 6kN

page 84

A-DQ(ZN)2Y (HD) Minicable

page 86

Fiber Data Sheet - Singlemodefiber E9

page 88

Fiber Data Sheet - Low Bend Sensitive Singlemodefiber E9

page 89

Fiber Data Sheet - NZDF-Singlemodefiber E8

page 90

Fiber Data Sheet - NZDF-Singlemodefiber E8

page 91

Fiber Data Sheet - Multimodefiber OM2 G50

page 92

Fiber Data Sheet - Multimodefiber OM3 (OM3+, OM4) G50

page 93

Fiber Data Sheet - Multimodefiber G62,5

page 94

Letter Symbols - Fiber Optics

page 95

Colour Codes - Fiber Optics

page 96

Fiber Optic
Cables

A-DF(ZN)2Y

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

75

Fiber Optical Outdoor Cables - Standard Design


Outdoor Cable, filled, loose tube construction

76

A-DF(ZN)2Y

Typ

number of tubes
+ fillers

number of
fibers / tube

numbers of
fibers

tube-diameter
approx. mm

tensile strength
max. N

weight
approx. kg/km

outer diameter
approx. mm

A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y

1+5
2+4
3+3
4+2
5+1
6+0

2 (4)
2 (4)
2 (4)
2 (4)
2 (4)
2 (4)

2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)

2,0
2,0
2,0
2,0
2,0
2,0

1500
1500
1500
1500
1500
1500

75
75
75
75
75
75

9,5
9,5
9,5
9,5
9,5
9,5

A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y

1+4
2+3
3+2
4+1
5+0
6+0

6
6
6
6
6
6

6
12
18
24
30
36

2,8
2,8
2,8
2,8
2,8
2,8

1500
1500
1500
1500
1500
1500

95
95
95
95
95
120

11,0
11,0
11,0
11,0
11,0
12,0

A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y

1+4
2+3
3+2
4+1
5+0
6+0

8
8
8
8
8
8

8
16
24
32
40
48

2,8
2,8
2,8
2,8
2,8
2,8

1500
1500
1500
1500
1500
1500

95
95
95
95
95
120

11,0
11,0
11,0
11,0
11,0
12,0

A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y

1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0

12
12
12
12
12
12
12
12
12
12
12

12
24
36
48
60
72
96
120
144
192
216

2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8

1500
1500
1500
1500
1500
1500
2000
2000
3000
3000
3000

95
95
95
95
95
120
145
185
235
215
245

11,0
11,0
11,0
11,0
11,0
12,0
13,7
15,5
17,3
16,7
17,7

A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y

4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0

24
24
24
24
24
24
24
24

96
120
144
192
240
288
384
432

2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8

1500
1500
1500
2000
2000
3000
3000
3000

95
95
125
150
195
245
230
260

11,0
11,0
12,0
13,7
15,5
17,3
16,7
17,7

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Typ

number of tubes
+ fillers

number of
fibers / tube

numbers of
fibers

tube-diameter
approx. mm

tensile strength
max. N

weight
approx. kg/km

outer diameter
approx. mm

A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

6
6
6
6
6
6

6
12
18
24
30
36

2,3
2,3
2,3
2,3
2,3
2,3

1500
1500
1500
1500
1500
1500

80
80
80
80
80
95

10,0
10,0
10,0
10,0
10,0
10,5

A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

8
8
8
8
8
8

8
16
24
32
40
48

2,3
2,3
2,3
2,3
2,3
2,3

1500
1500
1500
1500
1500
1500

80
80
80
80
80
95

10,0
10,0
10,0
10,0
10,0
10,5

A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y

1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0

12
12
12
12
12
12
12
12
12
12
12

12
24
36
48
60
72
96
120
144
192
216

2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3

1500
1500
1500
1500
1500
1500
2000
2000
3000
3000
3000

89
89
89
89
89
95
115
145
185
165
185

10,0
10,0
10,0
10,0
10,0
10,5
12,0
13,3
15,0
14,5
15,0

Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
jelly filled cable core
strength members (aramide yarns)
PE-sheath, UV-resistant, black

Technical Data
tensile strength

compressive strength
(crush)

Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink

impact

Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)

torsion

Note
longitudinally water-tight

kink, cable

On request
other number of tubes
increased tensile strength
reinforced outer sheath (2YV)
other sheath colours
coloured stripes
HDPE or LDPE sheath
other tube and fiber colours
Laying
usable for fixed laying in earth, ducts or conduits and outdoors
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request

kink, loose tube

min. bending radius

temperature range

water penetration

according to IEC 794-1-E1


according to EN 187 000-501
value: Please have a look at the relevant
chart.
according to IEC 794-1-E3
according to EN 187 000-504
value: 2500 N/10 cm
according to IEC 794-1-E4
according to EN 187 000-505
value: 25 Nm
according to IEC 794-1-E7
according to EN 187 000-508
value: 5 cycles 1 turn
according to IEC 794-1-E10
according to EN 187 000-511
value: The cables do not form a kink
when a loop is drawn together to a
diameter 12 times the cable nominal
diameter.
according to IEC 794-1-E16
according to EN 187 000-512
value: The loose tubes do not kink.
according to IEC 794-1-E11
according to EN 187 000-513
value: R = 20 x D (cable outer diameter)
according to IEC 794-1-F1
according to EN 187 000-601
storage and transport: -40C to +70 C
laying:
-5C to +60C
operation:
-30C to +70 C
according to IEC 794-1-F5
according to EN 187 000-605
No water on free end.

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Optic
Cables

Application
For telecommunication and information systems.

77

Fiber Optical Outdoor Cables - Standard Design


Outdoor Cable, filled, loose tube construction, metal-free rodent protection

78

A-DF(ZN)2Y4Y

Typ

number of tubes
+ fillers

number of
fibers / tube

numbers of
fibers

tube-diameter
approx. mm

tensile strength
max. N

weight
approx. kg/km

outer diameter
approx. mm

A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y

1
2
3
4
5
6

+
+
+
+
+
+

5
4
3
2
1
0

2
2
2
2
2
2

2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)

2,0
2,0
2,0
2,0
2,0
2,0

1500
1500
1500
1500
1500
1500

90
90
90
90
90
90

10,5
10,5
10,5
10,5
10,5
10,5

A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

6
6
6
6
6
6

6
12
18
24
30
36

2,8
2,8
2,8
2,8
2,8
2,8

1500
1500
1500
1500
1500
1500

115
115
115
115
115
134

12,0
12,0
12,0
12,0
12,0
13,0

A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

8
8
8
8
8
8

8
16
24
32
40
48

2,8
2,8
2,8
2,8
2,8
2,8

1500
1500
1500
1500
1500
1500

115
115
115
115
115
135

12,0
12,0
12,0
12,0
12,0
13,0

A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y

1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0

12
12
12
12
12
12
12
12
12
12
12

12
24
36
48
60
72
96
120
144
192
216

2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8

1500
1500
1500
1500
1500
1500
2000
2000
3000
3000
3000

115
115
115
115
115
136
170
210
265
240
275

12,0
12,0
12,0
12,0
12,0
13,0
14,7
16,5
18,3
17,7
18,7

A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y

4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0

24
24
24
24
24
24
24
24

96
120
144
192
240
288
384
432

2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8

1500
1500
1500
2000
2000
3000
3000
3000

120
120
145
175
220
275
255
290

12,0
12,0
13,0
14,7
16,5
18,3
17,7
18,7

(4)
(4)
(4)
(4)
(4)
(4)

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Typ

number of tubes
+ fillers

number of
fibers / tube

numbers of
fibers

tube-diameter
approx. mm

tensile strength
max. N

weight
approx. kg/km

outer diameter
approx. mm

A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y

1+4
2+3
3+2
4+1
5+0
6+0

6
6
6
6
6
6

6
12
18
24
30
36

2,3
2,3
2,3
2,3
2,3
2,3

1500
1500
1500
1500
1500
1500

95
95
95
95
95
110

11,0
11,0
11,0
11,0
11,0
11,5

A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y

1+4
2+3
3+2
4+1
5+0
6+0

8
8
8
8
8
8

8
16
24
32
40
48

2,3
2,3
2,3
2,3
2,3
2,3

1500
1500
1500
1500
1500
1500

95
95
95
95
95
110

11,0
11,0
11,0
11,0
11,0
11,5

A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y

1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0

12
12
12
12
12
12
12
12
12
12
12

12
24
36
48
60
72
96
120
144
192
216

2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3

1500
1500
1500
1500
1500
1500
2000
2000
3000
3000
3000

95
95
95
95
95
110
135
165
210
190
210

11,0
11,0
11,0
11,0
11,0
11,5
13,0
14,4
16,0
15,5
16,0

Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
filling of cable core
strength members (aramide yarns)
PE-sheath, UV-resistant, black
PA-protective cover, UV-resistant, transparent

Technical Data
tensile strength

compressive strength
(crush)

Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink

impact

Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)

torsion

Note
longitudinally water-tight

kink, cable

On request
other number of tubes
increased tensile strength
other sheath colours
coloured stripes
HDPE or LDPE sheath
other tube and fiber colours
Laying
usable for fixed laying in earth, ducts or conduits and outdoors
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request

kink, loose tube

min. bending radius

temperature range

water penetration

according to IEC 794-1-E1


according to EN 187 000-501
value: Please have a look at the relevant
chart.
according to IEC 794-1-E3
according to EN 187 000-504
value: 3000 N/10 cm
according to IEC 794-1-E4
according to EN 187 000-505
value: 25 Nm
according to IEC 794-1-E7
according to EN 187 000-508
value: 5 cycles 1 turn
according to IEC 794-1-E10
according to EN 187 000-511
value: The cables do not form a kink
when a loop is drawn together to a
diameter 12 times the cable nominal
diameter.
according to IEC 794-1-E16
according to EN 187 000-512
value: The loose tubes do not kink.
according to IEC 794-1-E11
according to EN 187 000-513
value: R = 20 x D (cable outer diameter)
according to IEC 794-1-F1
according to EN 187 000-601
storage and transport: -40C to +70 C
laying:
-5C to +60C
operation:
-30C to +70 C
according to IEC 794-1-F5
according to EN 187 000-605
No water on free end.

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Optic
Cables

Application
For telecommunication and information systems.

79

Fiber Optical Outdoor Cables - Standard Design


Outdoor Cable, filled, loose tube construction, metallic rodent protection

80

A-DF(ZN)2Y(SR)2Y

Typ

number of tubes number of


+ fillers
fibers / tube

numbers of
fibers

tube-diameter
approx. mm

tensile strength
max. N

weight
approx. kg/km

outer diameter
approx. mm

A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y

1+5
2+4
3+3
4+2
5+1
6+0

2 (4)
2 (4)
2 (4)
2 (4)
2 (4)
2 (4)

2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)

2,0
2,0
2,0
2,0
2,0
2,0

2000
2000
2000
2000
2000
2000

180
180
180
180
180
180

14,0
14,0
14,0
14,0
14,0
14,0

A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y

1+4
2+3
3+2
4+1
5+0
6+0

6
6
6
6
6
6

6
12
18
24
30
36

2,8
2,8
2,8
2,8
2,8
2,8

2500
2500
2500
2500
2500
3000

220
220
220
220
220
250

15,5
15,5
15,5
15,5
15,5
16,5

A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y

1+4
2+3
3+2
4+1
5+0
6+0

8
8
8
8
8
8

8
16
24
32
40
48

2,8
2,8
2,8
2,8
2,8
2,8

2500
2500
2500
2500
2500
3000

220
220
220
220
220
250

15,5
15,5
15,5
15,5
15,5
16,5

A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y

1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0

12
12
12
12
12
12
12
12
12

12
24
36
48
60
72
96
120
144

2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8

2500
2500
2500
2500
2500
3000
3500
4000
4500

220
220
220
220
220
250
290
345
410

15,5
15,5
15,5
15,5
15,5
16,5
18,0
20,0
21,7

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Typ

number of tubes number of


+ fillers
fibers / tube

numbers of
fibers

tube-diameter
approx. mm

tensile strength
max. N

weight
approx. kg/km

outer diameter
approx. mm

A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

6
6
6
6
6
6

6
12
18
24
30
36

2,3
2,3
2,3
2,3
2,3
2,3

2500
2500
2500
2500
2500
3000

195
195
195
195
195
215

14,2
14,2
14,2
14,2
14,2
15,0

A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

8
8
8
8
8
8

8
16
24
32
40
48

2,3
2,3
2,3
2,3
2,3
2,3

2500
2500
2500
2500
2500
3000

195
195
195
195
195
215

14,2
14,2
14,2
14,2
14,2
15,0

A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y

1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0

12
12
12
12
12
12
12
12
12

12
24
36
48
60
72
96
120
144

2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3

2500
2500
2500
2500
2500
3000
3500
4000
4500

195
195
195
195
195
215
245
290
345

14,2
14,2
14,2
14,2
14,2
15,0
16,2
17,7
19,5

Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
jelly filled cable core
strength members (aramide yarns)
PE-inner sheath
corrugated steel tape, laminated
PE-outer sheath, UV-resistant, black
Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink
Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)

Technical Data
tensile strength

compressive strength
(crush)
impact

torsion

kink, cable

Note
longitudinally water-tight
On request
other number of fibers (max. 432)
other number of tubes
increased tensile strength
reinforced outer sheath (2YV)
other sheath colours
coloured stripes
HDPE or LDPE sheath
other tube and fiber colours
dry filled version
Laying
usable for fixed laying in earth, ducts or conduits and outdoors
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request

kink, loose tube

min. bending radius

temperature range

water penetration

according to IEC 794-1-E1


according to EN 187 000-501
value: Please have a look at the relevant
chart.
according to IEC 794-1-E3
according to EN 187 000-504
value: 3000 N/10 cm
according to IEC 794-1-E4
according to EN 187 000-505
value: 25 Nm
according to IEC 794-1-E7
according to EN 187 000-508
value: 5 cycles 1 turn
according to IEC 794-1-E10
according to EN 187 000-511
value: The cables do not form a kink
when a loop is drawn together to a
diameter 12 times the cable nominal
diameter.
according to IEC 794-1-E16
according to EN 187 000-512
value: The loose tubes do not kink.
according to IEC 794-1-E11
according to EN 187 000-513
value: R = 20 x D (cable outer diameter)
according to IEC 794-1-F1
according to EN 187 000-601
storage and transport: -40C to +70 C
laying:
-5C to +60C
operation:
-30C to +70 C
according to IEC 794-1-F5
according to EN 187 000-605
No water on free end.

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Optic
Cables

Application
For telecommunication and information systems.

81

All-Dielectric-Self-Supporting Cables (ADSS)


Aerial Cable, single sheath, loose tube construction, metal-free

82

A-DQ(ZN)2Y(HD) ... 6kN

Typ

number of tubes
+ fillers

number of
fibers / tube

numbers of
fibers

tube-diameter
approx. mm

tensile strength
max. N

weight
approx. kg/km

outer diameter
approx. mm

A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y

1
2
3
4
5
6

+
+
+
+
+
+

5
4
3
2
1
0

2
2
2
2
2
2

2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)

2,3
2,3
2,3
2,3
2,3
2,3

6.000
6.000
6.000
6.000
6.000
6.000

140
140
140
140
140
140

13,0
13,0
13,0
13,0
13,0
13,0

A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

6
6
6
6
6
6

6
12
18
24
30
36

2,8
2,8
2,8
2,8
2,8
2,8

6.000
6.000
6.000
6.000
6.000
6.000

145
145
145
145
145
170

13,6
13,6
13,6
13,6
13,6
14,6

A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

8
8
8
8
8
8

8
16
24
32
40
48

2,8
2,8
2,8
2,8
2,8
2,8

6.000
6.000
6.000
6.000
6.000
6.000

145
145
145
145
145
170

13,6
13,6
13,6
13,6
13,6
14,6

A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y

1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0

12
12
12
12
12
12
12
12
12

12
24
36
48
60
72
96
120
144

2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8

6.000
6.000
6.000
6.000
6.000
6.000
6.000
6.000
6.000

145
145
145
145
145
170
200
245
300

13,6
13,6
13,6
13,6
13,6
14,6
16,2
18,0
19,8

(4)
(4)
(4)
(4)
(4)
(4)

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Application
Metal-free aerial cable (ADSS = alldielectric selfsupporting) for telecommunication and information systems.
Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
strength members (aramide yarns)
HDPE-outer sheath, UV-resistant, black

Technical Data
tensile strength
compressive strength
(crush)
impact

Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink

torsion

Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)

kink, cable

Note
not longitudinally water-tight
On request
other number of tubes
for temperatures down to -60C
other tube and fiber colours

kink, loose tube

Laying
usable for fixed laying on selfsupporting lines (up to 60kV) and
overhead contact lines, in earth, ducts or conduits and outdoors

temperature range

water penetration

span distance

Span distance calculation on request:


We need the following parameter values:
horinzontal distance from pole to pole: ? [m]
height difference from pole to pole: ? [m]
sag in meters or percent to the above mentioned values: ? [m-%]
ballast or added weight (ice and wind): ? [kg/m]

Fiber Optic
Cables

Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request

according to IEC 794-1-E1


according to EN 187 000-501
according to IEC 794-1-E3
according to EN 187 000-504
value: 3000 N/10 cm
according to IEC 794-1-E4
according to EN 187 000-505
value: 25 Nm
according to IEC 794-1-E7
according to EN 187 000-508
value: 5 cycles 1 turn
according to IEC 794-1-E10
according to EN 187 000-511
value: The cables do not form a kink
when a loop is drawn together to a
diameter 12 times the cable nominal
diameter.
according to IEC 794-1-E16
according to EN 187 000-512
value: The loose tubes do not kink.
according to IEC 794-1-F1
according to EN 187 000-601
storage and transport: -40C to +70 C
laying:
-5C to +60C
operation:
-30C to +70 C
according to IEC 794-1-F5
according to EN 187 000-605
value: No water on free end.
up to 100 m

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

83

All-Dielectric-Self-Supporting Cables (ADSS)


Aerial Cable, unfilled, loose tube construction, metal-free

Typ

84

number of tubes
+ fillers

number of
fibers / tube

A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y

1
2
3
4
5
6

+
+
+
+
+
+

5
4
3
2
1
0

2
2
2
2
2
2

A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y

1
2
3
4
5
6

+
+
+
+
+
+

4
3
2
1
0
0

A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y

1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0

(4)
(4)
(4)
(4)
(4)
(4)

numbers of
fibers

tube-diameter
approx. mm

A-D2Y(ZN)2Y ... 6kN

tensile strength
max. N

weight
approx. kg/km

outer diameter
approx. mm

2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)

2,3
2,3
2,3
2,3
2,3
2,3

6.000
6.000
6.000
6.000
6.000
6.000

135
135
135
135
135
135

13,0
13,0
13,0
13,0
13,0
13,0

6
6
6
6
6
6

6
12
18
24
30
36

2,8
2,8
2,8
2,8
2,8
2,8

6.000
6.000
6.000
6.000
6.000
6.000

140
140
140
140
140
165

14,1
14,1
14,1
14,1
14,1
14,6

8
8
8
8
8
8

8
16
24
32
40
48

2,8
2,8
2,8
2,8
2,8
2,8

6.000
6.000
6.000
6.000
6.000
6.000

140
140
140
140
140
165

14,1
14,1
14,1
14,1
14,1
14,6

12
12
12
12
12
12
12
12
12

12
24
36
48
60
72
96
120
144

2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8

6.000
6.000
6.000
6.000
6.000
6.000
6.000
6.000
6.000

140
140
140
140
140
162
196
246
295

14,1
14,1
14,1
14,1
14,1
14,6
16,2
18,1
20,0

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Application
Metal-free aerial cable (ADSS = alldielectric selfsupporting) for telecommunication and information systems.
Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
dry filled cable core
strength members (aramide yarns)
HDPE-outer sheath, UV-resistant, black

Technical Data
tensile strength
compressive strength
(crush)
impact

Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink

torsion

Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)

kink, cable

Note
not longitudinally water-tight

Laying
usable for fixed laying on selfsupporting lines (up to 60kV) and
overhead contact lines, in earth, ducts or conduits and outdoors
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request

kink, loose tube

temperature range

water penetration

span distance

Span distance calculation on request:


We need the following parameter values:
horinzontal distance from pole to pole: ? [m]
height difference from pole to pole: ? [m]
sag in meters or percent to the above mentioned values: ? [m-%]
ballast or added weight (ice and wind): ? [kg/m]

Fiber Optic
Cables

On request
other number of tubes
for temperatures down to -60C
other tube and fiber colours

according to IEC 794-1-E1


according to EN 187 000-501
according to IEC 794-1-E3
according to EN 187 000-504
value: 3000 N/10 cm
according to IEC 794-1-E4
according to EN 187 000-505
value: 25 Nm
according to IEC 794-1-E7
according to EN 187 000-508
value: 5 cycles 1 turn
according to IEC 794-1-E10
according to EN 187 000-511
value: The cables do not form a kink
when a loop is drawn together to a
diameter 12 times the cable nominal
diameter.
according to IEC 794-1-E16
according to EN 187 000-512
value: The loose tubes do not kink.
according to IEC 794-1-F1
according to EN 187 000-601
storage and transport: -40C to +70C
laying:
-5C to +60C
operation:
-30C to +70C
according to IEC 794-1-F5
according to EN 187 000-605
value: No water on free end.
up to 100 m

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

85

Stranded loose tube Mini cable with 4 - 144 optical fibers


Mini Cable, dry filled, loose tube construction, metal-free

Type

A-DQ(ZN)2Y (HD)

number
of fibers

number of tubes
(fillers)

tube-
approx. mm

tensile strength
max. N

outer-diameter
approx. mm

weight
approx. kg/km

A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)

1x4
1x8
1x12
2x12
3x12
4x12
5x12
6x12
8x12
12x12

4
8
12
24
36
48
60
72
96
144

1 (5)
1 (5)
1 (5)
2 (4)
3 (3)
4 (2)
5 (1)
6 (0)
8 (0)
12 (0)

1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5

700
700
700
700
700
700
700
700
700
700

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
6.5
8.5

30
30
30
30
30
30
30
30
43
63

A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)

1x4
1x8
1x12
2x12
3x12
4x12
5x12
6x12
8x12
12x12

4
8
12
24
36
48
60
72
96
144

1 (5)
1 (5)
1 (5)
2 (4)
3 (3)
4 (2)
5 (1)
6 (0)
8 (0)
12 (0)

1,7
1,7
1,7
1,7
1,7
1,7
1,7
1,7
1,7
1,7

900
900
900
900
900
900
900
900
900
900

6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
7.4
10.5

37
37
37
37
37
37
37
37
56
88

A-DQ(ZN)2Y (HD)

6x24

144

6 (0)

2,0

900

8.0

71

Application
Suitable for Metro, Access or FTTx implementations

Technical Data

Construction
rip cord
central member, metal free
loose buffer tube filled with a thixotropic gel, swellable aramid yarns
dry filled cable core
HDPE-sheath, UV-resistant, black

Temp. range

storage and transport


laying
operation

Crush resistance

900 N/10 cm

Impact strength

5 Nm (3 impacts, 300 mm hammer radius)

Water penetration
Bending radius

1 m (0.1 bar, 24 h)
permanent
during installation

Fiber colours
blue, orange, green, brown, slate, white, red, black, yellow, violet,
pink, turquoise

-30C up to +60C
-5C up to +50C
-30C up to +60C

65 mm
90 mm

Tube colours
up to 12 tubes: blue, orange, green, brown, slate, white, red, black,
yellow, violet, pink, turquoise
Filling element colour
natural
On request
other sheath colours
other tube and fiber colours
Laying
for installation in miniduct systems
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request
86

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Optic Cables

Fiber Optic
Cables

Note

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

87

Fiber Data Sheet


Singlemodefiber (SM)
Common
fiber type
standard
fiber decribtion

E9

E9/125 Singlemode Fiber


ITU-T G.652 D; EN188000, EN1888100, EN1888101; VDE 0888/part 102, VDE 0888/part 103, TS 0311/part 3
and TS 0311/part 2 of DTAG
The fiber is ideally designed for use in metropolitan, local and access networks due to its superior specifications - low optical loss aross the entire wavelength range from 1260 to 1625 nm, tightest available geometry,
low splice loss and low polarization mode dispersion.

Mechanical Properties
core diameter d
core concentricity error
cladding diameter
cladding non-circularity
cladding/coating concentricity error
coating non-circularity
fiber diameter

at 1310 nm
at 1550 nm

uncoloured
coloured

tensile strength according to EN 188000 PV201, 1s


strain level
coating strip force
bending radius
Optical Properties
attenuation

attenuation inequality (.......)


attenuation (Makrobending)
attenuation alteration (range -60 up to +85C)
attenuation for WDM/ES
chromatic dispersion

at 1310
at 1383
at 1490
at 1550
at 1625
at 1310
at 1310
at 1310
at 1550
at 1285
at 1260
at 1480

nm
nm
nm
nm
nm
and 1550 nm
and 1550 nm
and 1550 nm
20 nm
1330 nm
1360 nm
1580 nm

polarization mode dipersion (PMD)


PMD Link Design Value acc. IEC 60794/5.5 Method 1
fiber cut-off wavelength (referred to RTM)
cf-range

88

m
m
m
m
%
m
%
m
m
N
kpsi
N
mm

max / typical
0.34 / 0.32
0.31 / 0.28
0.23 / 0.21
0.21 / 0.19
0.23 / 0.20
0.05
0.05
0.05
0.22
3
12
19
0.1
0.06
11501330

dB/km
dB/km
dB/km
dB/km
dB/km
dB/km
dB
dB/km
dB/km
ps/(nm*km)
ps/(nm*km)
ps/(nm*km)
ps/km
ps/km
nm

1260

nm

point defect at pulse-width 10ns


zero dispersion wavelength

at 1310 and 1550 nm


0

0.05
1300 1322

dB
nm

zero dispersion slope

s0

0.092

ps/(nm*km)

refraction index

at 1310 nm
at 1550 nm

1.467
1.468

cable cut-off wavelength

cff-range

9.2 0.4
10.4 0.5
0.5
125 0.7
0.7
12.0
6.0
242 5
250 10
8
120
3.5
30

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Data Sheet


Singlemodefiber (SM) - Low Bend Sensitive

E9/125 Singlemode Fiber with higher Bend Performance


ITU-T G.657 A1, A2/B2; IEC 60793-2-50 type B.1.3
The macrobending and microbending loss improvements of this low bend sensitive fiber offer a number of advantages for demanding access, enterprise and central office applications. The fiber enables more compact cabinet and
enclosure designs and protects the network against excessive loss resulting from inadvertent fiber bends. It is less
susceptible to physical disturbancees from cable flexing, pulling and crushing, as well as the intricate routing conditions within enclosures and cabinets. The optimized bend characteristics of this fiber also help improve cable performance in demanding high-stress and low-temperature environments by providing double the microbend protection
of conventional singl-mode fibers.

Mechanical Properties
core diameter d
coreconcentricity error
cladding diameter
cladding non-circularity
cladding/coating concentricity error
coating non-circularity
fiber diameter

at 1310 nm
at 1550 nm

uncoloured
coloured

tensile strength according to EN 188000 PV201, 1s


strain level
coating strip force
bending radius
Optical Properties
attenuation

refraction index
attenuation inequality (.......)
attenuation alteration (range -60 up to +85C)
chromatic dispersion
polarization mode dipersion (PMD)
fiber cut-off wavelength (referred to RTM)

at 1310 nm
at 1383 nm
at 1490 nm
at 1550 nm
at 1625 nm
at 1310 nm
at 1550 nm
at 1310 and 1550 nm
at 1310 und 1550 nm
at 1288 1339 nm
at 1550 nm
cf-range

A2/B2
8.5 - 9.3
9.5 - 10.5
0.5
125 0.7
1.0
12.0
6.0
235 - 245
max. 265
8
100
3.5
10

max. / typical
0.35 / 0.34
0.31 / 0.28
0.24 / 0.21
0.21 / 0.19
0.24 / 0.20
1.467
1.468
0.05
0.05
3.5
18
0.2
11501330

max. / typical
0.35 / 0.34
0.31 / 0.28
0.24 / 0.21
0.21 / 0.19
0.24 / 0.20
1.467
1.468
0.05
0.05
3.5
18
0.2
11501330

m
m
m
m
%
m
%
m
m
N
kpsi
N
mm

dB/km
dB/km
dB/km
dB/km
dB/km

dB/km
dB/km
ps/(nm*km)
ps/(nm*km)
ps/km
nm

1260

1260

nm

point defect at pulse-width 10ns


zero dispersion wavelength

at 1310 and 1550 nm


0

0.05
1302 1322

0.05
1300 1324

dB
nm

zero dispersion slope

s0

0.092

0.092

ps/(nm*km)

at 1550 nm
at 1625 nm
at 1550 nm
at 1625 nm
at 1550 nm
at 1625 nm
at 1550 nm
at 1625 nm

0.01
0.05
0.2
0.5
0.2
0.5
-

0.03
0.1
0.1
0.2
0.5
1.0

dB
dB
dB
dB
dB
dB
dB
dB

cable cut-off wavelength

Macrobend Performances
100 turns on a 25mm radius mandrel
10 turns on a 15mm radius mandrel
1 turns on a 10mm radius mandrel
1 turns on a 7.5mm radius mandrel

cff-range

A1
8.5 - 9.3
9.5 - 10.5
0.5
125 0.7
1.0
12.0
6.0
235 - 245
max. 265
8
100
3.5
10

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Optic
Cables

Common
fiber type
standard
fiber describtion

E9

89

Fiber Data Sheet


NZDF-Singlemodefiber (NZDF)
Common
fiber type
standard
fiber describtion

E8

Non-Zero-Dispersion-Shifted Singlemode Fiber


ITU-T G.655, ITU-T G.656; EN188000, EN1888100, EN1888101
core consists of SiO2 doped with GeO2; optical cladding of quarzglass (SiO2); step profile of the refraction index,
matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins

Mechanical Characteristics

G.656
(G.655.c, e)
True-Wave
Reach
8.6 0.4
125 0.7
0.5
0.7
12.0
6.0
242 5
265
8

G.655.d
(G.655.c)
True-Wave
RS
8.4 0.6
8.7 0.6
125 0.7
0.5
0.7
12.0
6.0
242 5
265
8

Tera Light
MetroFiber
9.2 0.5
125 1
0.6
1.0
12.0
5.0
242 7
265
8

Tera Light
UltraFiber
9.2 0,5
125 1
0.6
1.0
12.0
6.0
242 7
265
8

9.6 0.4
125 0.7
0.5
0.7
12.0
6.0
245 5
265
8

m
m
m
m
%
m
%
m
m
N

100
3.5
30

100
3.5
30

100
3
30

100
3.5
30

100
3
30

kpsi
N
mm

at 1550 nm
at 1625 nm
at 1383 3 nm

0.22
0.24
0.4

0.22
0.24
0.4

0.25
0.28
1.0

0.22
0.25
0.7

0.22
0.24
0.4

dB/km
dB/km
dB/km

at 1550 nm
at 1625 nm

0.5
0.5

0.5
0.5

0.5
0.5

0.5
0.5

0.5
0.5

dB
dB

at 1550 nm
at 1625 nm

0.05
0.05
0.05

0.05
0.05
0.05

0.05
0.05
0.05

0.05
0.05
0.05

0.05
0.05
0.05

dB
dB
dB/km

at 1550 nm
at 1530 1565 nm
at 1565 1620 nm
link design value
max. individual fiber
at 1550 nm
at 1550 nm

0.05
5.5-8.9
6.9-11.4
0.04
0.1
0.05
1.470

0.05
2.6-6.0
4.0-8.9
0.04
0.1
0.05
1.470

0.05
5.5-10.0
7.5-13.8
0.08
0.2
0.1
1.469

0.1
5.5-10.0
7.5-13.4
0.04
0.05
1.469

0.05
2.6-6.0
4.5-11.2
0.04
0.1
0.05
1.468

dB
ps/(nm*km)
ps/(nm*km)
ps/km
ps/km
dB

core diameter d
cladding diameter
core/cladding excentricity
cladding non-circularity
cladding/coating excentricity
coating non-circularity
fiber diameter

at 1550 nm
at 1600 nm

uncoloured
coloured

tensile strength according to


EN 188000 PV201, 1s
strain level
stripping force
bending radius
Optical Characteristics
attenuation
attenuation (water peak)
attenuation (macrobending)
1 turn, 32mm
100 turns, 75mm1)
attenuation alteration
(range -60 up to +85C)
no point discontinuity
chromatic dispersion
polarisation modedispersion (PMD)
point defect
refraction index

1)

90

G.656
(G.655.e)

G.656
(G.655.e)
TM

G.655.d
TM

Leaf

at TeraLight Fibers: 60 mm
TM

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Data Sheet


NZDF-Singlemodefiber (NZDF)

Non-Zero-Dispersion-Shifted Singlemode Fiber


ITU-T G.655, ITU-T G.656; EN188000, EN1888100, EN1888101
PENGG KABEL offers non-zero dispersion shifted single mode optical fibers produced by the Vapour Phase Axial
Deposition (VAD) method, which enables construction of high-capacy, ultra long haul WDM systems. This fibers
allows the easier deployment of WDM in metropolitan areas, and increases the capacity of fiber in WDM systems
throughout the wavelength region between 1460 nm and 1625 nm (S, C, L-bands, 1460 nm only for G.656 fiber).
Its non-zero dispersion caracteristic reduces four-wave mixing and cross-phase modulation over a wider wavelength range than conventional NZDF. Our NZDF fibers has the ability to increase transmission speeds of systems
up to 10 Gb/s and 40 Gb/s and also has superior polarization mode dispersion performance.

Compostion
core
cladding
coating

Germanium doped silica


Silica
Dual layers of UV-cured acrylate

Geometrical Characteristics
core diameter d
cladding diameter
core/cladding concentricity error
cladding non-circularity
fiber curl radius
primary coating diameter
coating/cladding concentricity error
Optical Characteristics
attenuation

point discontinuity
chromatic dispersion

at 1550 nm

at
at
at
at
at
at
at

1460
1550
1625
1550
1460
1530
1565

nm (only G.656)
nm
nm
nm
to 1625 nm (only G.656)
to 1565 nm
to 1625 nm

cut-off wavelength of cabled fiber


PMD
individual fiber
link design value (typical)
Mechanical Characteristics
fiber proof test level
macrobending loss for
100 turns at a 75 or 60 mm mandrel diameter
1 turn at a 32 mm mandrel diameter
coating strip force
dynamic fatigue resistance parameter
Enviromental Characteristics
induced attenuation at 1310 nm and 1550 nm
from -60C to +85C temperature cycling
85C / 98% RH temperature humidity cycling
+85C heating aging
+23C water immersion

at 1550 (and 1625 nm at G.655.a)


at 1550 (and 1625 nm at G.655.a)

G.656
(G.655.c, e)
9.0 0.5
125.0 1.0
0.7
4
242 5
12

G.655.a
(G.655.d)
9.6 0.4
125.0 0.7
0.5
0.7
4
245 5
12

m
m
0.5
%
m
m
m

0.26
0.22
0.25
0.10
2.0 bis 13.5
5.5 bis 10.0
7.5 bis 13.5
1450

0.22
0.25
0.05
2.0 bis 6.0
4.5 bis 11.2
1450

dB/km
dB/km
dB/km
dB
ps/(nm*km)
ps/(nm*km)
ps/(nm*km)
nm

0.10
-

0.10
0.04

ps/km
ps/km

120

120

kpsi (1.2% strain)

0.05
0.5
1.3 bis 8.9
20

0.05
0.5
1.3 bis 8.9
20

dB
dB
N

0.05
0.05
0.05
0.05

0.05
0.05
0.05
0.05

dB/km
dB/km
dB/km
dB/km

Fiber Optic
Cables

Common
fiber type
standard
fiber describition

E8

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

91

Fiber Data Sheet


Multimodefiber (MM) OM 2 - Quality
Common
fiber type
standard
fiber describtion

G50

G50/125 according to VDE (Typ A1a), G50/125 according VE or TA


ITU-T G.651; EN188000, EN1888200, EN1888202; VDE0888/part 105, VDE0888/part 106, FZA TS0053/01
core consists of SiO2 doped with GeO2; optical cladding of quarzglass (SiO2); graded profile of the refraction index,
matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins

Mechanical Properties
core diameter d
core non-circularity
core/cladding concentricity error
cladding diameter
cladding non-circularity
cladding/coating concentricity error
coating non-circularity
fiber diameter

uncoloured
coloured

tensile strength according to EN 188000 PV201, 1s


strain level
stripping force
bending radius
Optical Properties
attenuation

band width
attenuation (makrobending)
attenuation alteration (range -60 up to +85C)
numeric aperture
refraction index
link lengths at 1 Gb/s

92

at
at
at
at
at

850nm
1300 nm
1383 nm
850 nm
1300 nm

at
at
at
at
at

850 nm
850 nm
1300 nm
850 nm
1300 nm

50 2.5
5.0
1.5
125 2
1.0
10.0
6.0
245 10
265
8
100
3.5
30

m
%
m
m
%
m
%
m
m
N
kpsi
N
mm

2.5
0.6
2.0
400 - 750
500 - 1200
0.5
0.2
0.2 0.015
1.4825
1.4775
500 - 750
550 - 2000

dB/km
dB/km
dB/km
MHz*km
MHz*km
dB
dB/km

(others on request)
(others on request)

m
m

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Data Sheet


Multimodefiber (MM) OM 3 - Quality (OM 3+ , OM 4)
Common
fiber type
standard
fiber describition

G50

G50/125 according to VDE (Typ A1a), G50/125 according VE or TA


ITU-T G.651; EN188000, EN1888200, EN1888202; VDE0888/part 105, VDE0888/part 106, FZA TS0053/01
core consists of SiO2 doped with GeO2; optical cladding of quarzglass (SiO2); graded profile of the refraction index,
matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins

Mechanical Properties
core diameter d
core non-circularity
core/cladding concentricity error
cladding diameter
cladding non-circularity
cladding/coating concentricity error
coating non-circularity
fiber diameter

uncoloured
coloured

tensile strength according to EN 188000 PV201, 1s


strain level
stripping force
bending radius
Optical Properties
attenuation

refraction index
attenuation (makrobending)
attenuation alteration (range -60 up to +85C)
numeric aperture

at
at
at
at
at

850nm
1300 nm
1383 nm
850 nm
1300 nm

at 850 nm

50 2.5
5.0
1.5
125 1
1.0
10.0
6.0
245 10
265
8
100
3.5
30

m
%
m
m
%
m
%
m
m
N
kpsi
N
mm

2.5
0.7
2.0
1.4825
1.4775
0.5
0.2
0.2 0.015

dB/km
dB/km
dB/km

dB
dB/km

Performance Characteristics

Upon request our fiber can be selected meeting inner mask radial specifications more stringent than the TIA/EIA-492 AAAC requirement:
Inner mask: Rinner = 0 m to Router = 18 m
Further to meeting the respective DMD template all OptiGrade fiber meets the additional requirement of IEC 60793-2-10 in the radial offset
intervall masks, which sources out fibers, having rapid changes of the DMD.
Transmission link lenghts
850 nm
300
400
500
550
m
for 10 Gb/s*
1300 nm (LX4)
300
300
300
300
m
*at 850 nm operating
radius 4.5 m
30 %
wavelenth with transmitters
radius 19.0 m
86 %
meeting encircled flux at

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Fiber Optic
Cables

OptiGrade Classes
300
400
500
550
Bandwith
850 nm
1500
2000
2500
3500
MHz*km
(Overfilled Launch, LED based sources) 1300 nm
500
500
500
500
MHz*km
Effective Modal Bandwith
850 nm
2000
2700
4000
4700
MHz*km
Assured by: Differential Mode Delay (DMD)
Fibers shall meet the respective DMD templates specified in or according to the standard TIA/EIA or IEC 60793-2-10, for transmitters meeting TIA/EIA-492 AAAC. Each template includes an inner and an outer mask requirement with:
Inner mask:
Outer mask:
Rinner = 5 m to Router = 18 m
Rinner = 0 m to Router = 23 m

93

Fiber Data Sheet


Multimodefiber (MM)
Common
fiber type
standard
fiber describition

G62,5

G62,5/125 according to VDE (Typ A1b), , G62,5/125 according VE or TA


EN188000, EN1888200, EN1888202; VDE0888/part 105, VDE0888/part 107, FZA TS0053/01
core consists of SiO2 doped with GeO2; optical cladding of quarzglass (SiO2); graded profile of the refraction
index, matched cladding, phosphorus free; protective coating consisting of two layers of UV-cured acrylate resins

Mechanical Properties
core diameter d
core non-circularity
cladding diameter
core/cladding concentricity error
cladding non-circularity
cladding/coating excentricity
coating non-circularity
fiber diameter

uncoloured
coloured

tensile strength according to EN 188000 PV201, 1s


strain level
stripping force
bending radius
Optical Properties
attenuation

band width
attenuation (makrobending)
attenuation alteration (range -60 up to +85C)
numeric aperture
refraction index
link lengths at 1 Gb/s

94

at
at
at
at
at

850nm
1300 nm
1383 nm
850 nm
1300 nm

at
at
at
at
at

850 nm
850 nm
1300 nm
850 nm
1300 nm

62.5 2.5
5.0
125 2
1.5
1.0
10.0
6.0
245 10
265
8
100
3.5
30

m
%
m
m
%
m
%
m
m
N
kpsi
N
mm

3.0
1.0
2.0
160 - 250
500 - 800
0.05
0.2
0.275 0.015
1.4965
1.4920
300 - 500
550 - 1000

dB/km
dB/km
dB/km
MHz*km
MHz*km
dB
dB/km
dB

(Standard 200)
(Standard 600)

m
m

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Letter Symbols - Fiber Optics


Letter symbols according to VDE (outdoor cables)

Fiber Optic
Cables

Letter symbols according to VDE (indoor cables)

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

95

Colour Codes - Fiber Optics


Colour Code - Fibers (Standard, others on request)
Pengg Standard Fiber Colouring:

Ring Signing:

Colour Code - Tubes (Standard)


5-tubes construction

1xn

2xn

3xn

4xn

5xn

1xn

2xn

3xn

4xn

5xn

Singlemode Fibers
NZDF-Fibers E8
Multimode Fibers G50

Multimode Fibers G62,5

no fiber assignment

6-tubes construction

6x n

Singlemode Fibers E9
NZDF-Fibers E8
Multimode Fibers G50

Multimode Fibers G62,5

no fiber assignment

96

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

General Information
Types

page 98

Letter symbols

page 99

Examples for telecommunication cables

page 99

Basic formulas for telecommunication technique

page 100

Units

page 100

Basic formulas for homogeneous, symmetrical cables

page 100

Shifting guideline

page 102

Bending radius

page 102

Installation temperature

page 102

Tensile load for control and telecommunication cables

page 102

Tensile load for telecommunication cables with guaranteeing tensile strength resistance page 103
Common explanations

page 104

Pictograms Copper Cables

page 104

Pictograms Fiber Optic Cables

page 105

Characteristic features of insulation and sheath material

page 105

RAL-colour code

page 106

Behaviour in case of fire, fire away line, fire load

page 107

Nominal data of wooden drums

page 109

Drums according to DIN 46391 (dimensions, weights)

page 109

Capacity (spooling length)

page 110
page 113

General
Information

Terms of delivery

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

97

Types
Signalling- and measuring cables

Switchboard cables

Signal and measuring cables are used for transmission of DC- and low Switchboard cables are used as connection between racks, main disfrequency AC-signals in telemetering-, signal-, clock- and paging tributors and switch stations in different kinds of railway offices (censystems as well as for control system (railway signals, signal boxes) tral offices, amplification bases and signal boxes).
and for supervision systems.
The cores are PVC-insulated. Cores are stranded together in layers;
The cables consist of PE-insulated cores, which are stranded together shielded pairs, triples, quads or quintuples are stranded together in
in concentric layers. The non-armoured types have a PVC-sheath over layers or units. The shielded types have a screening of aluminium lamithe cable core, the armoured types have a PVC-sheath (PE-sheath nated PET-foil (static shield) over the cable core, the switchboard
according to VE), a steel tape armouring and a PVC-outer protective cables have a PVC-sheath.
cover.

Local outdoor telecommunication cables

Telecommunication switchboard wires

They are used in local telecom networks, for the connection of tele- They are used for switching and wiring of telecommunication instruphone sets to telephone exchanges and as connection cables in indu- ments and similar ones, i.e. telephone exchanges, amplification bases
strial fields and in offices.
and selection amplifiers.
The cables have quads of PE-, foam-PE- or foam-skin-PE They consist of one or more twisted cores with PVC-insulation.
insulated cores; the quads are stranded to unitss, the units are stranded to the cable core. The composite-layer sheath have a double-coated aluminium foil bonded with the PE-sheath. Petrol jelly fillings or
swellable materials prevents water penetration along the cable.
Shielded switchboard strands
For special applications or customer-specifications the cables get They are used for switching of telecommunication instruments and
additionally components, for example:
similar ones, e.g. telephone exchanges, amplification bases and selection amplifiers.
PE-sheath, reinforced
steel tape or steel wire armouring
Shielded switchboard strands consists of one or more twisted, PVC PE or PVC protective cover
insulated cores, a copper braid screening and a PVC-sheath.
aluminium laminated PET-foil instead of aluminium
tape

Selfsupporting aerial cables

Telecommunication installation wires

Selfsupporting aerial carrier cables, so called SETRA cables, are used Telecommunication installation wires are used for switching of telewithin the telecommunication network of the PTTs as well as in the com instruments in dry and eventually dump areas.
domain of private telecom and data transmission networks.
They consists of one or more twisted PVC-insulated cores.
They have PE-insulated quads cabled to units and if necessary a
shielding of aluminium foil; cable core and a supporting rope of galvanized steel wires with common PE-sheath (e.g. PVC-sheath). Also
available with quads stranded in layers.

Installation cables

Special cables for telecommunication

They are mainly needed for construction of telephone sets and exten- Telecom cables for very specified applications and different special
sions and suited for fixed laying on dry and wet ground material indo- constructions (i.e. power protection cables, lightning protected teleor and outdoor.
communication cables,railway signalling cables with inductive protection,...) belong to this field.
The PVC-insulated pairs or quads are stranded together in layers or
units. Depending on the type the cables are unshielded or shielded
with an aluminium foil (static shield) and surrounded with a PVCsheath.

Cables for industrial electronics

Control cables

These cables are used for transmission of signals and measuring Control cables are used for transmission of analogue and digital sigvalues in units of the measuring, control and power electronic techni- nals. Special constructions have proven to work under difficult transques as well as for data processing.
fer conditions and extreme severe environmental influences.
They are composed of PVC-insulated cores or pairs stranded Main applications: industrial process control, refineries, fuel dumps,
together into units. The shielded types have a screening of aluminium chemical industry, power plants, as well as in sciences and research
foil or copper braid. The cables for industrial electronics have a PVC- work.
sheath.

98

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Letter symbols - copper cables


Letter
symbol

Description

Letter
symbol

Description

AA
AB
AD-

outdoor cable (GE)


aluminium shield (AT)
outdoor cable with high voltage protection (GE)
outdoor cable for power line protection (e.g. Differentialschutz) (GE)
outdoor cable with inductive protection (GE)
aluminium shield (DK)
aluminium-PE laminated sheath (DK)
armouring (AT/GE)
cables with units (GE)
one layer steel tape; ...mm thickness of steel tape
(GE)
protective cover of tarred jute (GE)
shield (copper braid) (GE)
shield (copper tape) (AT)
copper conductor (DK)
shield with stranded copper wires (GE)
Dieselhorst-Martin quad (GE)
drain wire (AT)
filling of cable core (GE)
quad with phantom utilization (GE)
installation cable, flat design (GE)
flat wire armouring (AT)
telecomunication outdoor cable (AT)
telecommunication indoor cable (AT)
foil (DK)
longitudinally aluminiumtape (GE)
flat wire; thickness in ...mm (GE)
conter helix (AT)
mine cable (GE)
skin (in foam-skin insulations) (AT)
peak value of mutual capacitance [nF/km] (GE)
cable core jelly filled (AT)
installations cable (GE)
installations cable for industrial electronics (GE)
element with metallic foil and drain wire (AT/GE)
additionally corrosion proofing over armouring (GE)
innersheath and shield of londgitudinally copper
tape (GE)
coax pair (AT/GE)
design with resistance to cold (GE)
smooth aluminium tape (GE)
laminated aluminium tape (GE)
composite layer sheath (GE)
sheathed flexible cable (GE)
corrugated aluminium sheath (GE)

LG
LI
M
MZ
2M
(M...)
OF
P
P
PAP
PE
perf
Q
(R...)
R
S
SSSMPE
SPE
ST

cabling in layers (GE)


stranded or bunched conductor (GE)
lead sheath (AT/GE)
lead sheath with addition of setting (GE)
lead sheath with addition of setting (AT)
max. mean value of mutual capacitance [nF/km] (GE)
filling of cable core with special material (GE)
paper insulation (AT/GE)
pair (GE)
paper (wrapping) (DK)
polyethylene (outer) sheath (DK)
perforated (GE)
steel wire braid (AT/GE)
round wire; diameter in ... mm (GE)
round wire armouring (AT)
railway signalling cable (GE)
switchboard cable (GE)
railway signalling cable (AT)
foam-skin-PE insulation (DK)
foam-PE insulation (DK)
quad in cables for long distances and phantom
utilisation (GE)
quad in cables for long distances (GE)
quad in local telecommuncation cables (GE)
set value of mutual capacitance [nF/km] (GE)
static shield of metallic tape or aluminium laminated pet-foil (GE)
suspension wire (AT/GE)
carrier frequency quad (GE)
swelling material (GE)
tinned copper wire (AT)
filling of cable core (DK)
tinned (GE)
corrugated steel sheath (GE)
PVC insulation, sheath or protective cover PVC (AT/GE)
PVC sheath or protective cover, reinforced (GE)
PVC sheath or protective cover, reinforced (AT)
steel- or PA-braid, rssistant to extension (GE)
glass yarn strength members (GE)
PE isulation, sheath or protective cover (AT/GE)
PE sheath or protective cover, reinforced (GE)
PE sheath or protective cover, reinforced (AT)
foam-PE insulation (AT/GE)
foam-skin-PE insulation (AT)
foam-skin-PE insulation (GE)

AJAL
AL+PE
B
BD
(1B...)
C
C
C
CU
D
DM
E
F
F
F
F
FFIFOL
(FA)
(F...)
G
GH
(H...)
J
JJE...IMF
-K
(K)
Kx
KF
L
(L)
(L)2Y
LLD

ST I
ST III
(S...)
(ST)
T
TF
TF
V
VAS
vzn
W
Y
YV
Y3V
(Z)
(ZG)
2Y
2YV
2Y3V
02Y
02YH
02YS

Examples for telecommunication cables


A-02YSF(L)2Y 200x2x0.8 ST III BD
Longitudinally waterproof local telecommunication cable with 100 foam-skin PE insulated quads, bare copper conductor, diameter 0.8 mm,
stranded to units, jelly filled, paper tape covering and composite layer sheath; (similar to FTZ).

Installation cablel with 20 PVC-insulated pairs, bare copper conductor, diameter 0,6 mm, stranded in layers, plastic tape wrapping, static
shield PETP aluminium foil with drain wire and PVC-sheath; (according to VDE 0815).
A-2YYBY 16x1x0.9 S LG
Railway signal cable with 16 PE insulated cores, stranded in layers, bare copper conductor, diameter 0.9 mm, plastic tape wrapping, PVCsheath, stell tape armouring and PVC protective cover (according to VDE 0816/part 2).
Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

General
Information

J-Y(ST)Y 20x2x0.6 LG

99

Basic Formulas of Telecommunication Technique


Units
Term

Symbol

Letter symbol

angular frequency
attenuation (equivalent)
attenuation coefficient
capacitance load per unit length
capacitance unbalance
conductivity
conductance
conductance per unit length
conductor cross section
conductor resistance
current, strength of current
dissipation factor
frequency
group delay
inductivity
inductivity load per unit length
insulation resistance
image phase change coefficient
impedance (amount)
impedance (complex)
impedance (imaginary part)
impedance (real part)
line length
level
magnetic unbalance
mutual capacitance
mutual inductance
near end cross talk attenuation (equivalent)
phase delay
power
reduction factor
reflection coefficient
relative permittivity
resistance load per unit length
specific resistance
temperature
velocity of propagation
voltage
wave length

a,

C
k, / k1 / k2,3 /k9-12 / e1,2

G
G
q
R
I
tan
f
g
L
L
Ris

Z
ZL
Zi
Zr
l
p
m
C
M
a n, n
p
P
rk
r
r
R
s
t
v
U

s-1
dB (Np)
dB/km (Np/km)
F/km
pF
Sm/mm
mS/km
S/km
mm
/km
A
Hz
s/km
mH/km
H/km
Mkm
rad/km

km
dB (Np)
nH
nF/km
mH/km
dB (Np)
s/km
W
/km
mm/m
C
bit/s
V
m

Unit
1/second
dezibel (neper)
dezibel (neper)/km
farad/km
pikofarad
siemensmeter/mm
millisiemens/km
siemens/km
millimeter
ohm/km
ampere
hertz
second/km
millihenry/km
henry/km
megaohmkilometer
rad/km
ohm
ohm
ohm
ohm
kilometer
dezibel (neper)
nanohenry
nanofarad/km
millihenry/km
dezibel (neper)
second/km
watt
ohm/km
ohm mm/m
degree celsius
bit/second
volt
meter

Basic formulas for homogeneous, symmetrical cables


Conductor resistance
Rt
R20
t
k

Complex characteristic impedance

resistance at t C in Ohm
resistance at 20C in Ohm
temperature in C
0.00393 for Cu or 0.00403 for Al

Angular frequency

Dissipation factor

()

100

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Basic Formulas of Telecommunication Technique


Basic formulas for homogeneous, symmetrical cables
Impedance (amount) at low frequencies
(voice frequency)

Impedance (amount) at high frequencies ( L>R)

()

()

L
C

Attenuation at low frequencies


(voice frequency)

inductivity (H/km)
mutual capacitance (F/km)

Attenuation at high frequencies (w L>R)

(Np/km)

R
G

loop resistance (/km)


conductance (S/km)

General
Information

(dB/km)

(Np/km)

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

101

Shifting Guideline
Bending radius
When laying and bending the cables as well as at the mounting points (e.g. brackets) the bending radius R may not come up to those
below stated. When forming out the cables during the assembly of appropriate treatment the minimum bending radius may be reduced at
the most to half of the indicated values.
Cable typ
installation cables, switchboard cables

Bending radius R
minimum value
7.5 x DA

outdoor cables with composite layer sheath 7.5 x DA


outdoor cables

10 x DA

DA .... cable outer diameter

Installation temperature
For the transfer not the ambient temperature but the temperature of the cable is determining. With low ambient temperatures cables can
be warmed up before shifting by suitable measures in such a way that the cable inside is not cooling under the permissible shifting temperature during the entire shifting procedure. Stress and jerks as well as stress by impact are to be avoided at low temperatures. The pulling speed of the cables should be as even as possible.
temperature range during installation:
cables with Polyethylene sheath (PE)
cables with Polyvinylchlorid sheath (PVC)

-20C up to +50C
-5C up to + 50C

Tensile load for control- and telecommunication cables

(according to VDE 0891/part 6)

The tensile stress indicated in the following tables applies uniformly to all for with guaranteeing tensile strength armouring cable, with
which is included the cable core frictional connected with the cable sheath - either over a tie rod with pulling eye or a firmly mounting
pulling trunk.

Number of

Maximum allowed value of tensile load [N]

cores
Conductor diam.

4
5
8
12
16
21
27
33
40
48
56
65
75
80
96
108
114
133
147
154
176
200

102

0.9
100
150
250
350
500
650
800
1000
1200
1450
1650
1950
2200
2350
2800
3100
3250
3700
4000
4200
4700
5300

1.4
300
400
600
900
1200
1500
1900
2300
2700
3200
3700
4300
4800
5100
6000
6800
7100
7900
8600
8900
9900
11000

1.8
500
650
1000
1450
1900
2400
3100
3700
4400
5300
5800
6700
7600
8000
9200
10000
10600
12000
13000
13500
15200
17000

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Shifting Guideline
Tensile strength of telecommunication outdoor cables with guaranteeing tensile strength resistance
Number of

Maximum allowed value of tensile load [N]

double cores
Conductor diam.

5
6
10
20
30
40
50
60
70
80
100
120
150
200
250
300
350
400
500
600
700
800
1000
1200
1500
2000

0.4
250
300
400
500
650
750
850
1000
1100
1400
1600
2000
2600
3300
3900
4300
4900
5900
6800
7600
8400
9800
11000
12500
14400

0.6
350
400
500
700
950
1200
1500
1700
2000
2300
2800
3400
4100
5200
6400
7400
8600
9600
11500
13200
14500
15500
17500
19000

0.8
600
1000
1500
2000
2500
2900
3400
3800
4600
5400
6600
8500
10000
11500
13000
14500
17000
19000
20500
21500

0.9
700
1300
1900
2500
3000
3500
4100
4600
5700
6600
8000
10000
12000
13500
15000
16300
18700

1.2
1200
2300
3200
4100
5000
6000
6700
7500
9000
10500
12500
15700
18800
20000

1.4
1600
2800
4000
5200
6400
7500
8500
9500
11400

The values in the tables above refer to unarmoured cables with no guaranteeing tensile strength armouring. If higher traction loads are
necessary, cables with a a garanteeing tensile strength armouring (steel round or rectangular wire) are to be planned.

General
Information

For the calculation of the tensile load for such cables applies an approximate value of 12 daN for each mm2 steel cross section.

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

103

Common Explanations
Pictograms Copper Cables
All datasheets are signed with common pictograms, which describe the cable make up and will lighten the localisation of the most applicable cable type.

Mutual capacitance
C35

C38

C42

C50

C52

C55

C60

Dimension of copper conductor


conductor diameter [mm]

0,4

0,5

0,6

0,8

triple

quad

0,9

1,0

1,2

1,4

1,8

cross section [mm2]

Cable elements
core

pair

quintuple

pair in metal foil PIMF

Number of double cores (DC)


DC, talking circuit
DC
4

DC
2-4

DC
4-8

DC
n

Filling
unfilled

petrol jelly

Fllnidz

dry filling / swellable materials

Overall screening, armouring


unshielded

104

foil

copper braid
or tape

foil and copper


braid

copper wires

composite layer (L)

armouring (steel tape,


round steel wires)

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Common Explanations
Pictograms Fiber Optic Cables
Construction
metal-free

halogenfree, flame retardant rodent protection

longitudinally water-tight

Application
indoor cable

outdoor cable

aerial cable (ADSS)

Characteristic features of insulation and sheath materials


Material

Resistance to
break-down
[kV/mm]

Spec. volume
resistance
[cm]

Continous possible
operating temperature
dauernd [C]

PVC (standard compound)


PVC (compound for telephon cores)
LDPE
HDPE
Foam-PE

25
25
70
85
60

1013
1015
1017
1017
1017

20
10
50
50
50

Material

Operating temperatur
(short time)
[C]

Decompositionor distortiontemperature [C]

Inflammability

PVC (standard compound)


PVC (compound for telephon cores)
LDPE
HDPE
Foam-PE

+100
+100
+100
+120
+90

+120
+120
+110
+130
+110

self-extinguishing
self-extinguishing
inflammable
inflammable
inflammable

Material

Waterabsorption
%

Weatherproof

Chemical
resistance
(general)

Radioresistance
x106 rad

PVC (standard compound)


PVC (compound for telephon cores)
LDPE
HDPE
Schaum-PE

0.4
0.4
0.1
0.1
0.1

good
good
good
limited
good

limited
limited
limited good
limited good
limited good

17
17
19
19
19

Material

Relative
permittivity

Density

58
34
2.3
2.3
1.6

to
to
to
to
to

+70
+70
+70
+90
+70

[g/cm3]

Tensile
strength
[MPa]

Breaking
elongation
%

Lettersymbol

1.45
1.4
0.92
0.945
0.65

15
20
20
25
10

250
200
400
500
500

Y
Y
2Y
2Y...HD
02Y

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

General
Information

PVC (standard compound)


PVC (compound for telephon cores)
LDPE
HDPE
Foam-PE

up
up
up
up
up

105

Common Explanations
RAL-colour code

106

colournumber

colour

hueexpresion

colournumber

colour

hueexpresion

1001
1012
1013
1014
1015
1016
1019
1021
2000
2002
2003
2004
3000
3002
3004
3015
4001
4003
4005
5002
5010
5012
5014

beige
yellow
white
ivory
beige
yellow
beige
yellow
orange
orange
orange
orange
red
red
red
pink
violet
violet
violet
blue
blue
blue
blue

beige
lemon yellow
oyster white
ivory
light ivory
sulfur yellow
grey beige
rape yellow
yellow orange
vermilion
pastel orange
pure orange
flame red
carmine red
purple red
light pink
red lilac
hether violet
blue lilac
ultramarine blue
gentian blue
light blue
pigeon blue

5015
5019
6000
6001
6003
6005
6010
6018
6027
7000
7001
7021
7032
7035
7037
8003
8011
8014
8024
9001
9005
9007
9010

light blue
blue
green
green
green
green
green
green
turquoise
grey
grey
grey
grey (ptt grey)
grey
grey
brown
brown
brown
brown
white
black
silver grey
white

sky blue
capri blue
patina green
emerald green
olive green
moss green
grass green
yellow green
light green
squirrel grey
silver grey
black grey
pebble grey
light grey
dusty grey
clay grey
nut brown
sepia brown
beige brown
cream
jet black
grey aluminium
pure white

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Behaviour in Case of Fire, Fire Away Line, Fire Load


Requirement
In the European standards EN 50167, EN 50168 and EN 50169 data
cables with halogen-free outer sheath are required. The consideration
and adherence to these standards are recommended particularly with
public setting e.g. hospitals, schools and airports. In addition with
other buildings with high person or real value concentration a use of
halogen-free cables is practical.

Cable with PVC-sheath


In the case of fire standard PVC materials can transmit fires and form
hydrochloric acid (HCI) by splitting off hydrogen chloride gas in
connection with moisture (e.g. fire fighting water). It continues to come
to a strong smoke development with burning PVC (polyvinyl chloride)
and the corrosive damage at buildings and equipment can often devastating extents assume, which exceed far the actual fire damage.

Testing method according to IEC 60332-1


Samples
From the end of the tested cable a sample piece of 60025 mm is taken.
Preparation (fig.1)
Propane from cylinder with burner, flame height 175 mm.
Sample is hung up vertically into the center of a metal box, (metal
box: h=120025 mm, b=30025 mm, t=45025 mm, front open).
Flame cone of the gas burner has to be fixed in an angle of 45 approx. 100 mm above the lower sample.
With cable diameter up to 50 mm one burner is used, with cable diameter over 50 mm two burners are used.
Execution

m
t = 60 +
25

t = duration of the flaming action in s


m = weight of the sample in g

Hereby materials are used, which do not contain halogens (e.g. chlorine)
and which do not set free corrosive gases in the case of fire. Also the
proportion of toxic gases is reduced to a minimum, and smoke development and fire away line are hardly still available or possible. Designation notes at the cable are e.g. the abbreviations FRNC or LSOH.
In detail these designations are meaning:
FR flame retardant
(fire-away-line-restraining)
NC non corrosiv
(no corrosive constituents)
LS low smoke
(low smoke development)
0H zero halogen (halogen-free)
Another big advantage by using such materials is, that the free view
on gears and escape routes is kept. Please note that you have to take
care that such kinds of materials are also used by other products,
e.g. power cables or cable run channels.

Fire load [kWh/m], [MJ/m]


In each building there are many different inflammable installations or
products. Also cable and cores (although hidden in intermediate ceilings or channels), which can in particular represent a substantial
component in administration buildings belong to them. These cables
have most divergent powers (heat values) and the total fire load of a
building could clearly increase. Therefore you should be pay attention
to the fact, when planning that the fire load quantities are kept as
small as possible.

Analysis
The test is considered as positively passed if the sample did not burn
or the flames automatically go out and the fire damage does not
reach the upper end of the sample.
Fire-pure e.g. soot lining and colour modification are not does claimed.

Testing method according to IEC 60332-2


Samples
From the end of the tested cable a sample piece of 60025 mm is taken.
Preparation
Propane from cylinder with burner, flame height 125 mm.
Sample is hung up vertically into the center of a metal box, (metal
box: h=120025 mm, b=30025 mm, t=45025 mm, front open).
Flame cone of the gas burner has to be fixed in an angle of 45 approx.
100 mm above the lower sample.
Execution
max. 20s
Analysis
The test is considered as positively passed if the sample did not burn
or the flames automatically go out and the fire damage does not
reach the upper end of the sample.
Fire-pure e.g. soot lining and colour modification are not does claimed.

General
Information

Cables with halogenfree sheath

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

107

Behaviour in Case of Fire, Fire Away Line, Fire Load


Testing methodes according to IEC 60332-3
Samples
From the end of the tested cable sample pieces of 360 mm are taken.
The number of samples depends on the cable diameter.

Testing method 1

Testing methode 3

Preparation (fig. 2)
The samples are arranged at the test rack as follows:
Telecommunication cables and cords as well as control cables and
cords with an outside diameter 30 mm without distance.
The number has to be selected in such a way that the grouping width
results of min.180 mm; the distance of the outside samples to the lateral side piece of the ladder should be approx. 90 up to 120 mm;
mounting of the samples with steel wires; the test rack is inserted
vertically into the suspension of the furnace. Dimensions of the
furnance as well as air volume and temperature are exactly regulated.
Burner, 77.74.8 l/min propane and 13.50.5 l/h air measured at
20C and 1 bar.
Before starting the test the test set-up has to be conditioned at room
temperature for mind. 16 h.
Flame of the gas burner has to be fixed in an angle of 90 approx. 600
mm above the lower sample end, in a distance of 75 mm.
Execution
Duration of the flaming action at least min. 20 minutes

Fig.1

Fig.2

The test according to test type 3 shows very realistically the possible
fire in a vertical duct.

Analysis
The test is considered as positively passed if the sample did not burn
or the flames automatically go out and the fire damage does not
reach the upper end of the sample.
Fire-pure e.g. soot lining and color modification are not does claimed.

108

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Nominal Data of Wooden Drums (DIN 46391)


Drums according to DIN 46391 (dimensions, weights)

identification
number

drum
dimesion

flange-diameter
D
[mm]

barrel-diameter width
d
B
[mm]
[mm]

traverse width carrying


b
capacity
[mm]
aprrox. [kg]

drumweight
aprrox. [kg]

051
E6
061
071
E8
081
091
E10
101
E12
121
E14
141
E16
161
162
E18
181
182
E20
201
202
E22
221
222
E24
250
251
252
E26
E28
281
E30

05
06
06
07
08
08
09
10
10
12
12
14
14
16
16/8
16/10
18
18/10
18/12
20
20/12
20/14
22
22/14
22/16
24
25/14
25/16
25/18
26
28
28/18
30

500
600
630
710
800
800
900
1000
1000
1200
1250
1400
1400
1600
1600
1600
1800
1800
1800
2000
2000
2000
2200
2240
2240
2400
2500
2500
2500
2600
2800
2800
3000

150
300
315
355
400
400
450
550
500
700
630
850
710
1000
800
1000
1150
1000
1250
1300
1250
1400
1450
1400
1600
1600
1400
1600
1800
1700
1800
1800
1900

400

315
400

400
560

560

666

660

844
835

835
825

1035
1030

1140
1130

1140
1130
1120

1280
1270

8
20
13
25
40
31
47
80
71
150
144
200
175
350
280
271
500
380
352
600
550
544
700
710
738
900
875
900
909
1100
1400
1175
1600

470
450
415
500
560
500
670
700
690
790
860
870
870
970
1060
1100
1110
1060
1100
1190
1310
1345
1330
1410
1475
1380
1450
1450
1475
1450
1650
1590

250
400

600
800

900

1700

2000

3000
3000

4000
4000

5000
5000

6000
6000

7500
7500
7500

10000
10000

General
Information

up to drum dimension 10 with cable bushing

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

109

Nominal Data of Wooden Drums (DIN 46391)


Capacity (spooling length in m)
identification
number
061
071
081
091
101
121
141
161
162
181
182
201
202
222

cable diameter in millimeter [mm]


6
7
8
9
10

cable-diameter 6 - 23 mm
11

12

13

14

15

16

17

20

21

22

93
165
219
402
576
1139
1352
2435
1849
2831
2772 2405 2076 1985

90
159
211
387
485
991
1304
2172
1600
2527
1704

122
167
315
468
856
1145
1931
1539
2248
1636

Capacity (spooling length in m)


identification
number
081
091
101
121
141
161
162
181
182
201
202
221
222
250
251
252
281
282

121
141
161
162
181
182
201
202
221
222
250
251
252
281
282

110

19

cable diameter in millimeter [mm]


24
25
26
27
28
156
294
377
709
967
1657
1278
1927
1343
2608
2096

151
285
365
688
839
1608
1235
1867
1295
2522
2023

32

33

34

209
428
537
866
655
1009
779
1500
1081
2035
1553
2978
2976 2893 2558 2491
2944 2848 2474 2398 2327 2004 1948

204
352
451
846
638
985
635
1289
1052
1984
1511
2908
2428
1896

344
441
828
622
962
618
1257
1024
1726
1264
2605
2134
1614

116
228
299
668
814
1419
1053
1650
1093
2218
1732

221
290
567
700
1244
1020
1450
1057
2150
1675
2861
2881 2493 2408 2329

215
282
551
681
1211
860
1409
1023
1879
1418
2777
2000

cable diameter in millimeter [mm]


42
43
44
45
46
190
259
529
348
61S
415
779
577
1107
877
1633
1406
963
1995
1666

254
437
341
511
315
763
565
1085
699
1603
1199
942
1956
1401

249
430
334
502
309
749
553
1064
684
1574
1175
923
1693
1373

245
422
328
492
302
611
542
890
670
1373
1153
904
1661
1345

240
415
321
484
296
600
531
874
657
1349
1131
886
1630
1319

23

117
161
304
389
827
999
1869
1324
2172
1394
2953
2629 2524 2176
2992

cable-diameter 24 - 41 mm
29

30

31

209
226
462
663
1180
835
1371
851
1826
1374
2450
1939

162
220
450
564
1028
811
1197
825
1583
1333
2383
1882

214
438
550
1003
789
1166
802
1540
1295
2089
1598

35

36

37

38

39

40

41

336
431
707
607
824
603
1227
998
1685
1232
2547
2083
1573
2890
2737 2663 2594 2242

329
422
692
493
806
587
1041
816
1646
1201
2271
2035
1534
2822
2186

265
348
678
482
788
466
1017
796
1418
1170
2223
1774
1286
2759
2134

259
341
664
471
772
454
994
777
1386
960
1969
1735
1255
2432
2084

254
334
560
460
653
444
972
759
1356
938
1930
1697
1226
2379
1780

249
327
549
451
640
434
812
742
1328
917
1892
1466
1199
2329
1740

244
264
539
356
627
424
795
590
1130
896
1664
1435
1172
2036
1702

Capacity (spooling length in m)


identification
number

18

1113
845
637
472
386
314
253
237
189
179
140
134
102
97
2024 1481 1064
892
677
564
468
385
364
297
239
228
218
172
2755 2340 1463 1152
980
761
643
542
454
430
358
294
281
228
2731 2202 1768 1404 1206 1032
881
749
632
603
505
485
2866 2349 1912 1540 1339 1159 1000
860
736
705
599
2727 2255 1991 1756 1545 1355 1784
2967 2479 2205 1959 1737 1535
2722
2903 2543 2220 2123

cable-diameter 42 - 59 mm
47

48

49

50

51

52

53

54

55

56

57

58

59

187
408
330
325
319
314
310
305
243
238
234
230
226
222
218
214
151
149
146
475
386
380
373
367
361
356
280
276
271
267
290
285
279
274
195
191
188
184
181
178
175
589
578
568
558
442
435
428
421
414
408
401
405
397
389
382
375
369
362
356
254
249
245
858
842
828
678
666
655
644
634
624
614
488
644
632
620
474
465
457
449
441
434
426
419
1326 1144 1125 1107 1089 1072
912
898
885
872
860
1110
931
914
898
883
869
713
701
690
679
668
708
694
681
668
656
645
633 48S
477
469
461
1600 1367 1343 1320 1298 1276 1073 1073 1039 1022 1006
1293 1065 1046 1026 1008
990
973
779
766
753
741

144
263
172
304
241
480
413
719
658
454
991
729

142
260
169
300
237
473
29S
709
649
446
815
718

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Nominal Data of Wooden Drums (DIN 46391)


Capacity (spooling length in m)
identification
number

cable diameter in millimeter [mm]


60
61
62
63
64

162
181
182
201
202
221
222
250
251
252
281
282

139
256
167
295
234
466
290
699
639
439
803
707

137
252
164
291
230
460
286
689
509
433
791
696

135
190
103
287
226
453
281
680
501
426
780
534

133
187
101
282
223
447
277
671
494
420
769
526

131
184
100
279
220
441
273
663
487
300
759
518

cable-diameter 60 - 77 mm
65

66

67

68

69

70

71

72

73

74

75

76

77

129
182
98
275
216
335
269
541
481
296
748
511

128
180
97
271
213
330
265
534
474
292
739
503

95
267
134
326
261
528
468
288
589
496

94
264
132
321
258
521
462
283
581
490

93
186
131
317
254
515
456
279
574
483

91
184
129
313
251
509
450
276
566
476

90
182
127
309
247
503
343
272
559
470

89
179
125
305
244
497
338
268
552
464

88
177
124
301
241
491
334
265
545
458

86
175
122
298
152
486
330
261
539
452

85
173
120
294
150
480
326
258
532
447

84
170
119
291
148
380
322
255
526
320

83
168
117
287
146
375
318
252
520
316

Capacity (spooling length in m)


cable diameter in millimeter [mm
78
79
80
81
82

201
202
221
222
250
251
252
281
282

166
116
284
144
371
314
248
514
312

164
114
281
143
367
311
245
508
308

163
113
278
141
363
307
242
503
305

161
112
196
139
360
304
240
383
301

159
110
194
137
356
300
237
379
297

83

84

85

86

87

88

89

90

91

92

93

157
109
192
136
352
297
234
375
294

108
190
134
349
294
148
371
291

106
188
133
345
291
146
367
287

105
186
131
342
288
144
363
284

104
184
130
338
285
143
359
281

103
182
128
335
202
143
355
278

102
180
127
332
200
140
352
275

101
178
125
329
198
138
348
272

99
176
124
248
196
137
345
269

98
175
123
245
194
135
341
266

97
173
121
243
192
134
338
264

94

95

120

119

190
132
335
261

188
131
331
258

General
Information

identification
number

cable-diameter 78 - 95 mm

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

111

Railway Cables
Note

112

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

Terms of Delivery
General terms of delivery
for cables, furnitures and insulated cords from Pengg Kabel GmbH, later named Seller.
1.

Scope

1.1. These General Terms shall govern legal transactions between business enterprises, namely the delivery of commodities and, mutatis mutandis, the rendering of services. Software transactions are with precedence governed by the 6.
Software Conditions issued by the Austrian Electrical and Electronics Industry 6.1.
Association, assembly work by the Terms and Conditions for Assembly Work
issued by the Austrian Power Current and Light Current Engineering Industry
and/or (where applicable) the Terms and Conditions for the Assembly of Elec- 6.2.
trical Equipment used in Medicine issued by the Austrian Electrical and Electronics Industry (the current versions are available at www.feei.at).

used on account of Sellers failure to deliver an essential part thereof, provided


the Buyer has suffered a damage to the aforesaid extent. Assertion of rights of
damages exceeding this extent is precluded.
Passage of risk and place of performance
Unless otherwise agreed, the delivery of goods is considered sold EXW in
accordance with INCOTERMS 2010.
For services, the place of performance shall be the place indicated in the written order confirmation, secondary to that at which the service is actually rendered by Seller. The risk in respect of such services or any part thereof shall
pass to Buyer at the time the services have been rendered.
Payment

1.2. Any departure from the terms and conditions mentioned in 1.1 above shall be
7.
valid only if expressly accepted in writing by Seller.
7.1. Unless otherwise agreed, one third of the purchase price shall fall due at the
2.
Submission of offers
time of receipt by Buyer of the order confirmation of Seller, one third after half
2.1. Sellers offers shall be deemed offers without engagement.
the delivery period has elapsed and the balance at the time of delivery. Irre2.2. Tender documents and project documentation must not be duplicated nor
spective thereof the turnover tax comprised in the amount of the invoice shall
made available to third parties without the permission of Seller. They may be
be paid within 30 days of the invoice date. If bankruptcy proceedings are insticlaimed back at any time and shall be returned to Seller immediately if the order
tuted against the assets of Buyer or if an application for bankruptcy proceeis placed elsewhere.
dings is not granted for insufficiency of assets, deliveries shall only be made
against cash in advance.
3.
Conclusion of contract
3.1. The contract shall be deemed concluded upon written confirmation by Seller of 7.2. In the case of part settlements the individual part payments shall fall due upon
receipt of the respective invoices. The same shall apply to amounts invoiced for
an order received or upon dispatch of a delivery.
additional deliveries or resulting from additional agreements beyond the scope
3.2. Particulars appearing in catalogues, folders etc. as well as any oral or written
of the original contract, irrespective of the terms of payment agreed upon for
statements shall only be binding if Seller makes express reference to them in
the principal delivery.
the confirmation of the order.
7.3. Payment shall be made without any discount free Sellers domicile in the agre3.3. Subsequent amendments of or additions to the contract shall be subject to
ed currency. Drafts and checks shall be accepted on account of payment only,
written confirmation.
with all interest, fees and charges in connection therewith (such as collection
and discounting charges) to be borne by Buyer.
4.
Prices
4.1. Prices shall be quoted ex works or ex Sellers warehouse without VAT, packing 7.4. Buyer shall not be entitled to withhold or offset payment on the grounds of any
warranty claims or other counterclaims.
and packaging, loading, disassembly, take-back and proper recycling and disposal of waste electrical and electronic equipment for commercial purposes as 7.5. Payment shall be deemed to have been effected on the date at which the amodefined by the Ordinance Regulating the Handling of Waste Electrical Equipunt in question is at Sellers disposal.
ment. Buyer shall be liable for any and all charges, taxes or other duties levied
7.6.
If
Buyer fails to meet the terms of payment or any other obligation arising from
in respect of delivery. If the terms of delivery include transport to a destination
this or other legal transactions, Seller may without prejudice to his other rights
designated by Buyer, transport costs as well as the cost of any transport insurance desired by Buyer shall be borne by the latter. Delivery does not, however,
a) suspend performance of his own obligations until payments have been made
include unloading and subsequent handling. Packaging materials will be taken
or other obligations fulfilled, and exercise his right to extend the period of deliback only by express agreement.
very to a reasonable extent,
4.2. Seller reserves the right to modify prices if the order placed is not in accordance with the offer submitted.

b) call in debts arisen from this or any other legal transactions and charge
default interest amounting to 1.25 % per month plus turnover tax for these
amounts beginning with the due dates, unless Seller proves costs exceeding
this.

4.4. In carrying out repair orders, Seller shall provide all services deemed expedient
and shall charge Buyer for the same on the basis of the work input and/or
expenditures required. The same holds for any services or additional services
the expediency of which becomes apparent only as the repair order is execu- 7.7.
ted. In such an event special notification of Buyer shall not be required.
7.8.
4.5. Expenses for estimates of costs of repair and maintenance or for expert valuations shall be invoiced to Buyer.
5.

Delivery

5.1. The period allowed for delivery shall commence at the latest of the following
dates:
a) the date of order confirmation by Seller;
b) the date of fulfilment by Buyer of all the conditions, technical, commercial
and other, for which he is responsible;
c) the date of receipt by Seller of a deposit or security due before delivery of the
goods in question.

c) only perform other legal transactions against cash in advance in the case of
qualified insolvency, in other words, following two delays in payment.
In any case Seller has the right to invoice all expenses arising prior to a lawsuit,
especially reminder charges and lawyers fees.
Discounts or bonuses are subject to complete payment in due time.
Seller retains title to all goods delivered by him until receipt of all amounts invoiced including interests and charges.
Buyer herewith assigns his claim out of a resale of conditional commodities,
even if they are processed, transformed or combined with other commodities,
to Seller to secure the latters purchase money claim. In the case of resale granting respite Buyer shall have the power of disposal of the product under retention of ownership only with the proviso that upon reselling Buyer notifies the
secondary buyer of the assignment for security or enters the assignment in his
account books. Upon request Buyer has to notify the assigned claim and the
debtor thereof to Seller, and to make all information and material required for
his debt collection available and to notify the assignment to the third-party debtor. If the goods are attached or otherwise levied upon, Buyer shall draw attention to Sellers title and immediately inform Seller of the attachment or levy.

5.2. Buyer shall obtain whatever licences or approvals may be required from authoWarranty and acceptance of obligation to repair defects
rities or third parties for the construction of plant and equipment. If the granting 8.
of such licences or approvals is delayed for any reason the delivery period shall 8.1. Once the agreed terms of payment have been complied with, Seller shall, subbe extended accordingly.
ject to the conditions hereunder, remedy any defect existing at the time of
acceptance of the article in question whether due to faulty design, material or
5.3. Seller may carry out, and charge Buyer for, partial or advance deliveries. If delimanufacture, that impairs the functioning of said article. From particulars
very on call is agreed upon, the commodity shall be deemed called off at the
appearing in catalogues, folders, promotional literature as well as written or oral
latest one year after the order was placed.
statements which have not been included in the agreement no warranty obli5.4. In case of unforeseeable circumstances or circumstances beyond the parties
gations may be deduced.
control, such as all cases of force majeure, which impede compliance with the
agreed period of delivery, the latter shall be extended in any case for the dura- 8.2. Unless special warranty periods operate for individual items the warranty period shall be 12 months. These conditions shall also apply to any goods suption of such circumstances; these include in particular armed conflicts, official
plied, or services rendered in respect of goods supplied, that are firmly attainterventions and prohibitions, delays in transport or customs clearance, damached to buildings or the ground. The warranty period begins at the point of pasges in transit, energy shortage and raw materials scarcity, labour disputes, and
sage of risk acc. to paragraph 6.
default on performance by a major component supplier who is difficult to replace. The aforesaid circumstances shall be deemed to prevail irrespective of 8.3. For improved or exchanged parts, the warranty period shall start again, but
whether they affect Seller or his subcontractor(s).
shall end in any case 6 months after the original warranty period has expired.
5.5. If a contractual penalty for default of delivery was agreed upon by contracting 8.4. If delivery or the performance of services is delayed for reasons outside the
parties when the contract was concluded, it shall be executed as follows, and
control of Seller, the warranty period shall begin 2 weeks after Seller is ready
any deviations concerning individual items shall not affect the remaining provito deliver or perform services.
sions: Where delay in performance can be shown to have occurred solely
through the fault of Seller, Buyer may claim for each completed week of delay 8.5. The foregoing warranty obligations are conditional upon the Buyer giving within
a reasonable period notice in writing of any defects that have occurred and
an indemnity of at most one half of one per cent, a total of no more than 5 %,
such notice reaching the Seller. Buyer shall prove within a reasonable period
however, of the value of that part of the goods to be delivered which cannot be

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations

General
Information

4.3. Prices are based on costs obtaining at the time of the first quotation. In the
event that the costs have increased by the time of delivery, Seller shall have the
right to adjust prices accordingly.

113

Terms of Delivery
General terms of delivery (continued)
the presence of a defect, in particular he shall make available within a reasonable period to Seller all material and data in his possession. Upon receipt of
such notice Seller shall, in the case of a defect covered by the warranty under
8.1 above, have the option to replace the defective goods or defective parts
thereof or else to repair them on Buyers premises or have them returned for
repair, or to grant a fair and reasonable price reduction.
8.6. Any expenses incurred in connection with rectifying defects (e. g. expenses for
assembly and disassembly, transport, waste disposal, travel and site-to-quarters time) shall be borne by Buyer. For warranty work on Buyers premises
Buyer shall make available free of charge any assistance, hoisting gear, scaffolding and sundry supplies and incidentals that may he required. Replaced
parts shall become the property of Seller.
8.7. If an article is manufactured by Seller on the basis of design data, design drawings, models or other specifications supplied by Buyer, Sellers warranty shall
be restricted to non-compliance with Buyers specifications.
8.8. Sellers warranty obligation shall not extend to any defects due to assembly
and installation work not undertaken by Seller, inadequate equipment, or due
to non-compliance with installation requirements and operating conditions,
overloading of parts in excess of the design values stipulated by Seller, negligent or faulty handling or the use of inappropriate materials, nor for defects
attributable to material supplied by Buyer. Nor shall Seller be li- able for damage due to acts of third parties, atmospheric discharges. Excess voltage and
chemical influences. The warranty does not cover the replacement of parts
subject to natural wear and tear. Seller accepts no warranty for the sale of used
goods.
8.9. The warranty shall lapse immediately if, without written consent of Seller, Buyer
himself or a third party not expressly authorised undertakes modifications or
repairs on any items delivered.
8.10. Claims acc. to 933b ABGB are struck by the statute of limitation with lapse
of the period mentioned under point 8.2.
8.11. The provisions of sub-paragraphs 8.1 to 8.10 shall apply, mutatis mutandis, to
all cases where the obligation to repair defects has to be accepted for other
reasons laid down by law.
9.
Withdrawal from contract
9.1. Buyer may withdraw from the contract only in the event of delays caused by
gross negligence on the part of Seller and only after a reasonable period of
grace has elapsed. Withdrawal from contract shall be notified in writing by registered mail.
9.2. Irrespective of his other rights Seller shall be entitled to withdraw from the contract
a) if the execution of delivery or the inception or continuation of services to be
rendered under the contract is made impossible for reasons within the responsibility of Buyer and if the delay is extended beyond a reasonable period of
grace allowed;
b) if doubts have arisen as to Buyers creditworthiness and if same fails, on Sellers request, to make an advance payment or to provide adequate security
prior to delivery, or
c) if, for reasons mentioned in 5.4, the period allowed for delivery is extended
by more than half of the period originally agreed or by at least 6 months, or
d) if Buyer does not or does not properly meet the obligations imposed as per
paragraph 13.
9.3. For the reasons given above withdrawal from the contract shall also be possible in respect of any outstanding part of the delivery or service contracted for.
9.4. If bankruptcy proceedings are instituted against Buyer or an application for
bankruptcy proceedings is not granted for insufficiency of assets, Seller may
withdraw from the contract without allowing a period of grace. If this withdrawal is taken, it shall take effect immediately upon the decision that the business will not be continued. If the business will be continued, a withdrawal shall
not take effect until 6 months after the institution of bankruptcy proceedings or
after an application for bankruptcy proceedings has not been granted for insufficiency of assets. In any case, the contract shall be terminated immediately
unless the bankruptcy law to which Buyer is subject conflicts with this or if termination of the contract is necessary to prevent significant damages to Seller.
9.5. Without prejudice to Sellers claim for damages including expenses arising prior
to a lawsuit, upon withdrawal from contract any open accounts in respect of
deliveries made or services rendered in whole or in part shall be settled according to contract This provision also covers deliveries or services not yet accepted by Buyer as well as any preparatory acts performed by Seller. Seller shall,
however, have the option alternatively to require the restitution of articles already delivered.
9.6. Withdrawal from contract shall have no consequences other than those stipulated above.
9.7. The assertion of claims on the ground of laesio enormis, error, or lapse of purpose by the Buyer is excluded.
10.

10.2. The Buyer incorporated in Austria shall ensure that the Seller is provided with
all information necessary to meet the Sellers obligations as
manufacturer/importer, particularly according to 11 and 24 of the Ordinance
Regulating the Handling of Waste Electrical Equipment and the Waste Management Act.
10.3. The Buyer incorporated in Austria is liable vis--vis the Seller for any dam- age
and other financial disadvantages incurred by Seller due to Buyers failure to
meet or fully meet his financing commitment or any other obligations according
to Article 10. The Buyer shall bear the burden of proof of performance of this
obligation.
11.

Sellers liability

11.1. Outside the scope of the Product Liability Act, Seller shall be liable only if the
damage in question is proved to be due to intentional acts or acts of gross negligence, within the limits of statutory provisions. Seller's total liability in cases of
gross negligence is limited to the net value of the order or EUR 500,000, depending on which amount is lower.
11.2. For each incident of damage, Seller shall be liable for 25% of the net value of
the order or EUR 125,000, depending on which amount is lower.
11.3. Seller shall not be liable for damage due to acts of ordinary negligence nor for
consequential damages or damages for pure economic loss, indirect damages,
loss of production, financing costs, costs for replacement energy, loss of energy, data or information, loss of profits, loss of savings or interest, or damage
resulting from third-party claims against buyer.
11.4. Seller shall not be liable for damages in case of non-compliance with instructions for assembly, commissioning and operation (such as are contained in
instructions for use) or non-compliance with licensing requirements.
11.5. Claims that exceed the contractual penalties that were agreed on are excluded
from the respective title. The provisions of paragraph 11 apply exclusively for
all claims by Buyer against Seller, regardless of the legal basis or entitlement,
and also apply to all employees, subcontractors and subsuppliers of Seller.
12.

Industrial property rights and copyrights

12.1. Buyer shall indemnify Seller and hold him harmless against any claims for any
infringement of industrial property rights raised against him if Seller manufactures an article pursuant to any design data, design drawings, models or other
specifications made available to him by Buyer.
12.2. Design documents such as plans and drawings and other technical specifications as well as samples, catalogues, prospectuses, pictures and the like shall
remain the intellectual property of Seller and are subject to the relevant statutory provisions governing reproduction, imitation, competition etc. The provisions of 2.2 above shall also cover design documents.
13.

Compliance with export provisions

13.1. When passing on goods delivered by Seller to third parties (as well as any related documentation, regardless of the method of provision or the services performed by Seller [including technical support of any kind]), Buyer must comply
with the applicable regulations of national and international (re-)export provisions. In any case, Buyer must observe the (re-)export provisions of Seller's
country of residence, the European Union and the United States of America.
13.2. If necessary for export controls, Buyer must provide Seller with all necessary
information immediately after being requested to do so, for example, information about the final recipient, final destination and purpose of the goods or services.
14.

General
Should individual provisions of the contract or of these provisions be invalid the
validity of the other provisions shall not be affected. The invalid provision shall
be replaced by a valid one, which comes as close to the target goal as possible.

15.

Jurisdiction and applicable law


Any litigations arising under the contract including litigations over the existence or non-existence thereof shall fall within the exclusive jurisdiction of the
competent court at Sellers domicile; the competent court of the Bezirksgericht
Innere Stadt, Vienna, shall have exclusive jurisdiction if Seller is domiciled in
Vienna. The contract is subject to Austrian law excluding the referral rules.
Application of the UN Convention on Contracts for the International Sale of
Goods is renounced.

16.

Proviso
The execution of the contract by Seller is subject to the condition that there are
no obstacles standing in the way of execution due to national or international
(re-)export provisions, and especially no embargos and/or other sanctions.

Last revised in September 2011

Disposal of waste electrical and electronic equipment

10.1. The Buyer of electrical/electronic equipment for commercial purposes, incorporated in Austria, is responsible for the financing of the collection and treatment of waste electrical and electronic equipment as defined by the Ordinance
Regulating the Handling of Waste Electrical Equipment, if he is himself the user
of the electrical/electronic equipment. If the Buyer is not the end user, he shall
transfer the full financial commitment to his customer by agreement and furnish
proof thereof to the Seller.

114

Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations