Professional Documents
Culture Documents
Introduction
Railway Cables
Plant Kapfenberg-Eind
Pengg Kabel GmbH is an Austrian cable manufacturer and a member of the german Wilms group with two plants in Styria. We have
two sites, one in Kapfenberg where we produce copper cables and
the second in Wartberg where we are specialised on fiber optic
cables and components. At the location in Kapfenberg-Eind we
have been producing railway cables for more than 40 years.
In order to ensure the quality of our products and services and to
improve continuously the processes, we have already in the midnineties set up a quality management system according to EN ISO
9001 which is certified by an accredited body.
With our production equipment we are able to produce all usual
kinds of stranding such as layer-stranding, SZ-stranding and random stranding. On this basis, we are able to produce the main types
of railway and telecommunication cables.
Telecommunication cables:
conductor diameter 0,4 mm up to 1,8 mm
symmetric local and district cables
symmetric indoor cables
all types of jumper wires according to national and international
standards and/or customers specifications.
Differential protection cables:
conductor diameter 0,4 mm and 1,8 mm
Cables for watersupply- as well as for power-supply companies:
with pairs, triples or quads
special filling materials
different kinds of electrical shielding
Control cables for railway applications, special cables:
with plastic insulation
with cores, pairs or quads
spare cables in plastic version for paper-lead cables
Flexibility and customer proximity are the bases for a successful
development on the market. New developments and product improvements are always necessary. Apart of the permanent search for
improvements of our products, our efforts for the future run towards
reduction of production time, increase of flexibility and constant
improvement of quality, in order to be a reliable partner for our customers.
Contact Persons
Railway Cables
Managing Director:
Area representatives:
Max Rothwangl
Managing Director
PROCABLE S.A.
Isabelle & Udo Guldner
Luxembourg
max.rothwangl@penggkabel.at
7, Z.I. Bombicht
URL: www.procable.lu
L-6947 Niederanven
Luxembourg
Interteam Srl
Mauro Rota
Via C. Battisti, 50
rota.mauro@inter-team.it
werner.lenger@penggkabel.at
URL: www.inter-team.it
Italy
Sales Director:
Uwe Lcker
Key Account Manager
(B, BG, BY, CH, CY, DK, E, EST, FIN, GR, H, I, IRL, L, LT, LV,
N, P, RO, S)
+971 (0)503508277
+971 (4)4434698
HQ Building A109/1
swl501@gmail.com
Spyros Sakelliou
sasta@otenet.gr
Guy Colman
+32 (0)32532350
+32 (0)32532351
Laagstraat 65
guy.colman@cynerpro.be
URL: www.cynerpro.be
uwe.loecker@penggkabel.at
UAE
Sasta/Sakelliou Spyros & CO OE
Key Accounts:
Robert Hofreiter
Key Account Manager
(A, AL, BIH, HR, KOS, MK, MNE, SLO, SRB)
robert.hofreiter@penggkabel.at
Holger Quest
Key Account Manager
(D)
B-9140 Temse
holger.quest@penggkabel.at
Belgium
Gerd Pichler
Key Account Manager
(I, NL, D)
Am Flecken 24
+49 (0)1728141232
D-96450 Coburg
giorgio.cumbat@
gerd.pichler@penggkabel.at
Germany
Cableteam FZE
Stefan Leicht
t-online.de
Index
from page 7
from page 17
from page 57
from page 65
from page 69
from page 73
from page 75
General Information
from page 97
Railway Cables
Note
S-X2YA2YB2Y 1x4x1,53 HD
page 8
page 9
S-2Y2YBY ..x4x..
page 10
page 11
page 12
S-2Y2YBY ..x.. RE
page 13
S-2YY ..x..
page 14
F-2Y2YC2Y ..x2x0,8
page 15
Austrian Railways
(BB)
Austrian Railways, BB
Austrian Railways
PE insulated, star-quad, with inductive protection
S-X2YA2YB2Y 1x4x1,53 HD
C42
mutual capacity
filling
cable elements
overall shield,
armouring
number of
double cores
S-X2YA2YB2Y 1x4x1,53 HD
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
a core : transparent
b core : transparent
c core : RD
d core : RD
Screening:
Sheath:
Armouring:
Protective cover:
outer diameter
approx. mm
Application
The cable is designed for the connection of ETCS-Balisen.
number of
double cores
dimension of
conductor
1,53
Type
15,0
weight
approx. kg/km
292,8
Customer information
Conductor diameter:
1,53
mm
Loop resistance:
19,8
/km
Insulation resistance:
10
Gkm
nF/km
Attenuation:
1,8 MHz
1,0
dB/100m
120+/-20
K1
400
pF/km
ea1/2
650
pF/km
conductor/conductor
2000
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
during operation
-30 to +60
during installation
-20 to +50
Impedance:
1,8 MHz
Capacitance unbalance:
Dielectric strength:
Temperature range:
Marking
type - LEU - SIGNAL (4 x) - PENGG KABEL - <meter> - order number
Austrian Railways
Type
mutual capacity
#
1,83
dimension of
conductor
filling
cable elements
overall shield,
armouring
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
a core : transparent
b core : transparent
c core : RD
d core : RD
Screening:
Sheath:
Armouring:
Protective cover:
outer diameter
approx. mm
Application
The cable is designed for the connection of ETCS-Balisen.
number of
double cores
C45
number of
double cores
19,9
Austrian Railways
(BB)
weight
approx. kg/km
450,4
Customer information
1,83
mm
Loop resistance:
19,8
/km
Insulation resistance:
Gkm
nF/km
Attenuation:
1,8 MHz
1,0
dB/100m
120+/-20
k1
400
pF/km
ea1/2
650
pF/km
conductor/conductor
2000
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
during operation
-35 to +60
during installation
-20 to +50
Impedance:
1,8 MHz
Capacitance unbalance:
Dielectric strength:
Temperature range:
Marking
type - LEU - SIGNAL (4 x) - PENGG KABEL - <meter> - order number
Austrian Railways
PE insulated, star-quads, with rodent protection
S-2Y2YBY ..x4x..
C42
0,8
mutual capacity
0,9
number of
double cores
2-100
dimension of
conductor
1,4
filling
overall shield,
armouring
cable elements
Type
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
1x4x...
2x4x...
3x4x...
5x4x...
7x4x...
10x4x...
15x4x...
20x4x...
25x4x...
number of
double cores
outer diameter
approx. mm
weight
approx. kg/km
outer diameter
approx. mm
weight
approx. kg/km
outer diameter
approx. mm
weight
approx. kg/km
2
4
6
10
14
20
30
40
50
11,6
15,6
16,3
18,7
20,0
25,2
28,5
29,8
35,4
186,7
303,0
326,0
432,4
503,8
714,4
932,2
1040,1
1379,2
12,3
17,8
18,7
20,5
22,0
28,0
31,6
33,1
39,9
208,2
363,3
392,7
511,1
600,4
822,7
1125,0
1326,3
1706,8
15,5
23,4
24,6
29,2
31,6
40,5
47,1
49,4
60,0
236,6
612,8
721,4
977,2
1181,6
1684,7
2371,1
2843,9
3770,0
Application
The cable is desigend for use in railway protection systems.
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
beginning quad
other quads
BK
transparent
b core:
RD
RD
c core:
GN
GN
d core:
BU
BU
a core:
Sheath:
Armouring:
Protective cover:
VE- K 11 / 4 06.95
Conductor diameter:
0,8
0,9
1,4
Loop resistance:
72,3
56,6
23,4 /km
Insulation resistance:
10
mm
Gkm
42
nF/km
95%
40
nF/km
75%
38
nF/km
Capacitance unbalance:
100%
800
pF/300m
95%
400
pF/300m
K9-12
300
pF/300m
ea1/2
650
pF/300m
pF/425m
K1
K1
Marking
PENGG KABEL - type- BB sign - <meter> ; SIGNAL fills the free space for
gaps, less then 10 cm
100%
185
185
(6 quads) -
70
70
pF/425m
K9-12
170
170
pF/425m
ea1/2
550
550
pF/425m
Dielectric strength:
conductor/conductor
2500
V/50Hz/2min
conductor/shield
2500
V/50Hz/2min
250
Veff
during operation
-30 to +60
during installation
-20 to +50
Operating voltage:
Temperature range:
10
Austrian Railways
S-2Y2YCB2Y x4x (J) HD
C42
0.9
mutual capacity
1.4
2-100
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
S-2Y2YCB2Y
number of
double cores
1x4x...
2x4x...
3x4x...
5x4x...
7x4x...
10x4x...
15x4x...
20x4x...
25x4x...
outer diameter
approx. mm
outer diameter
approx. mm
2
4
6
10
14
20
30
40
50
16,1
22,0
21,5
25,5
27,0
32,2
36,2
37,5
44,9
Application
The cable is desigend for use in railway protection systems.
Construction
Conductor:
Insulation:
Colour code:
weight
approx. kg/km
RD
RD
c core:
GN
GN
d core:
BU
BU
441
670
711
946
1026
1349
1659
1918
2459
Screening:
Armouring:
Protective cover:
Marking
PENGG KABEL - type- BB sign - <meter> ; SIGNAL fills the free space for
gaps, less then 10 cm
19,3
27,2
28,8
33,0
36,0
46,5
52,3
54,4
65,2
weight
approx. kg/km
629
1012
1141
1455
1743
2869
3611
4149
5007
VE- K 11 / 4 06.95
Conductor diameter:
0,9
1,4
mm
Loop resistance:
56,6
23,4
/km
Insulation resistance:
10
Gkm
100%
42
nF/km
95%
40
nF/km
75%
38
nF/km
100%
185
Capacitance unbalance:
K1
Sheath:
number of
double cores
Austrian Railways
(BB)
185
pF/425m
(6 quads) 70
70
pF/425m
K9-12
170
170
pF/425m
ea1/2
550
550
pF/425m
Dielectric strength:
conductor/conductor
2500
2500
V/50Hz/2min
conductor/shield
2500
2500
V/50Hz/2min
250
250
Veff
Operating voltage:
Temperature range:
during operation
-30 to +60
during installation
-20 to +50
Reduction factor:
11
Austrian Railways
PE insulated, single core, with inductive protection
#
1,5
#
2,5
#
4,0
5-80
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY
S-2Y2YCBY
number of
cores
5x...
10x...
15x...
20x...
30x...
60x...
80x...
5
10
15
20
30
60
80
outer diameter
approx. mm
outer diameter
approx. mm
outer diameter
approx. mm
weight
approx. kg/km
17,7
21,0
23,6
25,2
28,1
35,8
40,5
Application
The cable is designed for use in railway protection systems, for underground
laying and drawing into conduits.
The cross section of this cable type goes from 0,75 to 25 mm.
Construction
Conductor:
Insulation:
Colour code:
number of
cores
576
745
929
1067
1339
2144
3028
weight
approx. kg/km
19,3
24,2
26,5
28,4
32,1
42,2
48,1
679
978
1195
1406
1804
3429
4286
weight
approx. kg/km
21,6
24,3
30,2
32,7
37,6
50,3
57,4
770
1190
1572
1827
2445
4889
6219
VE- K 10 / 10 06.95
1,5
2,5
4,0
mm
Conductor resistance:
12,1
7,28
4,56
/km
Insulation resistance:
Mutual capacitance:
120
120
120
nF/km
Gkm
Dielectric strength:
conductor/conductor
3500
3500
3500
V/50Hz/2min
conductor/shield
3500
3500
3500
V/50Hz/2min
800
800
800
Veff
Operating voltage:
Temperature range:
Sheath:
during operation
-30 to +60
Screening:
during installation
-5 to +50
Armouring:
Protective cover:
circular (R)
Reduction factor:
12
Austrian Railways
S-2Y2YBY ..x.. RE
mutual capacity
#
0,75
#
1,5
5-100
dimension of
conductor
#
2,5
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
S-2Y2YBY
number of
cores
5x...
10x...
15x...
20x...
30x...
60x...
80x...
100x...
5
10
15
20
30
60
80
100
overall shield,
armouring
outer diameter
approx. mm
outer diameter
approx. mm
outer diameter
approx. mm
weight
approx. kg/km
12,5
15,0
16,4
17,4
19,8
25,6
28,8
32,0
Application
The cable is designed for use in railway protection systems, for underground
laying and drawing into conduits.
The cross section of this cable type goes from 0,75 to 25 mm.
228
316
392
463
596
1024
1281
1532
293
434
562
684
895
1605
2086
2530
weight
approx. kg/km
15,5
19,6
21,9
24,6
28,3
37,2
42,1
48,2
373
592
767
996
1341
2403
3076
3858
VE- K 10 / 10 06.95
0,75
1,5
2,5
mm
Conductor resistance:
24,5
12,1
7,28
/km
100
120
Insulation resistance:
solid, bare copper wire
Mutual capacitance:
Insulation:
PE (2Y)
Dielectric strength:
weight
approx. kg/km
14,1
17,4
19,2
20,8
23,7
31,2
35,7
40,0
Construction
Conductor:
Colour code:
number of
cores
filling
cable elements
Type
Austrian Railways
(BB)
Gkm
5
120
nF/km
conductor/conductor
2500
3500
3500
V/50Hz/2min
conductor/shield
2500
3500
3500
V/50Hz/2min
400
800
800
Veff
Operating voltage:
Temperature range:
Sheath:
during operation
-30 to +60
Armouring:
during installation
-5 to +50
Protective cover:
circular (R)
single core (E)
Marking
PENGG KABEL - type- BB sign - <meter> ; SIGNAL fills the free space for
gaps, less then 10 cm
13
Austrian Railways
PE insulated, single core
S-2YY ..x..
mutual capacity
#
0,75
#
1,5
#
2,5
5-100
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
S-2YY
S-2YY
S-2YY
S-2YY
S-2YY
number of
double cores
10x1,5
10x2,5
19x0,75
19x1,5
19x2,5
VE- K 10 / 10 06.95
0,75
1,5
2,5
mm
Conductor resistance:
24,5
12,1
7,28
/km
120
120
Insulation resistance:
Mutual capacitance:
100
Insulation:
PE (2Y)
Dielectric strength:
Sheath:
287
418
289
468
730
weight
approx. kg/km
14,4
16,8
14,0
17,0
21,0
Construction
Conductor:
Colour code:
Gkm
nF/km
conductor/conductor
2500
3500
3500
V/50Hz/2min
conductor/shield
2500
3500
3500
V/50Hz/2min
400
800
800
Veff
Marking
PENGG KABEL - type- BB sign - <meter> ; SIGNAL fills the free space for
gaps, less then 10 cm
14
outer diameter
approx. mm
10
10
19
19
19
Application
The cable is designed for use in railway protection systems, for underground
laying and drawing into conduits.
The cross section of this cable type goes from 0,75 to 25 mm.
number of
cores
Operating voltage:
Temperature range:
during operation
-30 to +60
during installation
-5 to +50
Austrian Railways
F-2Y2YC2Y ..x2x0,8
C55
0.8
Type
F-2Y2YC2Y
F-2Y2YC2Y
F-2Y2YC2Y
F-2Y2YC2Y
mutual capacity
filling
cable elements
overall shield,
armouring
outer diameter
approx. mm
6
14
20
40
Application
The cable is desigend as speaker cable for railway telecommunication.
Construction
number of
double cores
dimension of
conductor
number of
double cores
6x2x0,8
14x2x0,8
20x2x0,8
40x2x0,8
6-40
14
17
20
23
weight
approx. kg/km
210
340
440
730
Conductor diameter:
0,8
mm
Loop resistance:
72,3
/km
Conductor:
Screen resistance:
Insulation:
PE (2Y)
20
Insulation resistance:
10
Gkm
55
nF/km
Colour code:
beginning quad
other quads
BK
transparent
Capacitance unbalance:
b core:
RD
RD
c core:
GN
GN
d core:
BU
BU
a core:
Sheath:
Screening:
Protective cover:
Austrian Railways
(BB)
100%
800
pF/300m
95%
400
pF/300m
K9-12
300
pF/300m
ea1/2
800
pF/300m
conductor/conductor
2500
V/50Hz/2min
conductor/shield
2500
V/50Hz/2min
K1
Dielectric strength:
Marking
order number - type - BB sign - <meter> - PENGG KABEL - month and year
of production - handset symbol
15
Austrian Railways
Note
16
page 19
page 20
page 21
page 22
page 23
page 24
page 25
page 26
page 27
page 28
page 29
page 30
page 31
page 32
page 33
page 34
page 35
page 36
page 37
page 38
page 39
page 40
page 41
page 42
page 43
page 44
page 45
page 46
page 47
page 48
page 49
page 50
A-2Y(L)2YB2Y 1x4x
page 51
AJ-2Y(L)2YDB2Y 1x4x1,53
page 52
Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations
German Railways
(DB)
German Railways, DB
17
German Railways, DB
18
page 53
page 54
page 55
German Railways
A-2YOF(L)2YB2Y ..x1x.. S (H115/H145)
2-200
0,9
1,4
1,8
dimension of
conductor
OF
cable elements
Type
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
A-2YOF(L)2YB2Y
number of
cores
2x1x.. S
4x1x.. S
7x1x.. S
10x1x.. S
14x1x.. S
20x1x.. S
24x1x.. S
30x1x.. S
40x1x.. S
50x1x.. S
60x1x.. S
80x1x.. S
100x1x.. S
120x1x.. S
140x1x.. S
160x1x.. S
180x1x.. S
200x1x.. S
number of cores
filling
overall shield,
armouring
outer diameter
approx. mm
outer diameter
approx mm
outer diameter
approx. mm
2
4
7
10
14
20
24
30
40
50
60
80
100
120
140
160
180
200
13,0
13,0
14,0
17,0
17,0
18,0
20,0
20,0
21,0
23,0
25,0
26,0
31,0
32,0
35,0
36,0
39,0
39,0
weight
approx. kg/km
160
170
220
290
300
380
460
490
590
700
800
1000
1250
1390
1650
1790
2030
2150
14,0
17,0
18,0
19,0
22,0
23,0
24,0
27,0
29,0
32,0
35,0
39,0
41,0
44,0
46,0
49,0
50,0
weight
approx. kg/km
240
320
410
490
630
730
840
1050
1280
1490
1920
2350
2730
3140
3540
3970
4310
16,0
19,0
21,0
22,0
25,0
27,0
29,0
32,0
36,0
38,0
42,0
47,0
49,0
53,0
55,0
59,0
60,0
weight
approx. kg/km
300
430
560
680
890
1060
1230
1560
1940
2280
2920
3630
4230
4890
5490
6160
6710
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0113
Conductor diameter:
0,9
1,4
1,8
mm
Loop resistance:
28,9
11,9
7,2
/km
Insulation resistance:
1,5
1,5
1,5
Gkm
145
145
nF/km
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
Filling:
Laminated sheath:
Armouring:
Protective cover:
PE (2Y), black
Design:
(H115)
(H145)
(H145)
600
600
600
V/DC
420
420
420
Veff/100Hz
2500
2500
V/AC/1min
2500
2500
V/AC/1min
Operating voltage:
German Railways
(DB)
Temperature range:
during installation
-10 to +60
during operation
-40 to +60
19
German Railways
PE-insulated, single core, with inductive protection
dimension of
conductor
0,9
10200
number of cores
OF
filling
cable elements
Type
number of
cores
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
10x1x0,9 S (H115)
20x1x0,9 S (H115)
30x1x0,9 S (H115)
50x1x0,9 S (H115)
80x1x0,9 S (H115)
120x1x0,9 S (H115)
160x1x0,9 S (H115)
200x1x0,9 S (H115)
10x1x0,9 S (H115)
20x1x0,9 S (H115)
30x1x0,9 S (H115)
50x1x0,9 S (H115)
80x1x0,9 S (H115)
120x1x0,9 S (H115)
160x1x0,9 S (H115)
200x1x0,9 S (H115)
10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
overall shield,
armouring
outer diameter
approx. mm
21,0
22,0
24,0
27,0
30,0
35,0
39,0
41,0
21,0
22,0
24,0
27,0
30,0
35,0
39,0
41,0
weight
approx. kg/km
650
750
900
1190
1560
2040
2500
2930
750
870
1040
1320
1740
2230
2720
3160
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0113
Conductor diameter:
0,9
mm
Loop resistance:
28,9
/km
Insulation resistance:
10
Gkm
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
Filling:
Laminated sheath::
Screening:
nF/km
(H115)
Reduction factor:
acc.to DB AG 416.0116
Operating voltage:
600
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Temperature range:
during installation
-10 to +60
during operation
-40 to +60
Armouring:
Protective cover:
PE (2Y), black
Design:
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
20
German Railways
AJ-2YOF(L)2YDB2Y ..x1x1,4 S (H145)
dimension of
conductor
1,4
10200
number of cores
OF
filling
cable elements
Type
number of
cores
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
10x1x1,4 S (H145)
20x1x1,4 S (H145)
30x1x1,4 S (H145)
50x1x1,4 S (H145)
80x1x1,4 S (H145)
120x1x1,4 S (H145)
160x1x1,4 S (H145)
200x1x1,4 S (H145)
10x1x1,4 S (H145)
20x1x1,4 S (H145)
30x1x1,4 S (H145)
50x1x1,4 S (H145)
80x1x1,4 S (H145)
120x1x1,4 S (H145)
160x1x1,4 S (H145)
200x1x1,4 S (H145)
50x1x1,4 S (H145)
80x1x1,4 S (H145)
120x1x1,4 S (H145)
160x1x1,4 S (H145)
200x1x1,4 S (H145)
10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
50
80
120
160
200
600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
400
400
400
400
400
overall shield,
armouring
outer diameter
approx. mm
22,0
26,0
28,0
33,0
38,0
44,0
49,0
53,0
22,0
26,0
28,0
33,0
38,0
45,0
50,0
54,0
36,0
42,0
48,0
53,0
57,0
weight
approx. kg/km
790
1090
1350
1890
2630
3560
4460
5290
920
1230
1490
2080
2850
3880
4790
5650
2770
3770
4870
5880
6830
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0113
Conductor diameter:
1,4
mm
Loop resistance:
11,9
/km
Insulation resistance:
10
Gkm
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
nF/km
(H145)
Reduction factor:
acc. to DB AG 416.0116
Operating voltage:
600
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Filling:
Laminated sheath::
Screening:
during installation
-10 to +60
during operation
-40 to +60
Armouring:
Protective cover:
PE (2Y), black
Design:
German Railways
(DB)
Temperature range:
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
20
German Railways
PE-insulated, single core, with inductive protection
dimension of
conductor
1,8
cable elements
Type
number of
cores
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
10x1x1,8 S (H145)
20x1x1,8 S (H145)
30x1x1,8 S (H145)
50x1x1,8 S (H145)
80x1x1,8 S (H145)
120x1x1,8 S (H145)
160x1x1,8 S (H145)
200x1x1,8 S (H145)
10x1x1,8 S (H145)
20x1x1,8 S (H145)
30x1x1,8 S (H145)
50x1x1,8 S (H145)
80x1x1,8 S (H145)
120x1x1,8 S (H145)
160x1x1,8 S (H145)
200x1x1,8 S (H145)
30x1x1,8 S (H145)
50x1x1,8 S (H145)
80x1x1,8 S (H145)
120x1x1,8 S (H145)
160x1x1,8 S (H145)
200x1x1,8 S (H145)
10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
30
50
80
120
160
200
600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
400
400
400
400
400
400
10200
number of cores
OF
filling
overall shield,
armouring
outer diameter
approx. mm
25,0
29,0
33,0
39,0
45,0
52,0
58,0
63,0
25,0
29,0
33,0
39,0
46,0
53,0
59,0
64,0
36,0
43,0
49,0
56,0
62,0
67,0
weight
approx. kg/km
1010
1420
1840
2670
3770
5210
6600
7900
1150
1570
2010
2870
4090
5560
6980
8320
2690
3800
5100
6730
8290
9730
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0113
Conductor diameter:
1,8
mm
Loop resistance:
7,2
/km
Insulation resistance:
10
Gkm
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
nF/km
(H145)
Reduction factor:
acc. to DB AG 416.0116
Operating voltage:
60
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Filling:
Laminated sheath::
Screening:
during installation
-10 to +60
during operation
-40 to +60
Armouring:
Protective cover:
PE (2Y), black
Design:
Temperature range:
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
22
German Railways
A-2YOF(L)2YB2Y ..x1x.. S (H95)
1,4
1,8
4-80
number of cores
OF
filling
dimension of
conductor
cable elements
Type
number of
cores
4
7
10
14
20
24
30
40
50
60
80
overall shield,
armouring
outer diameter
approx mm
weight
approx. kg/km
outer diameter
approx. mm
weight
approx. kg/km
16,0
18,0
21,0
22,0
25,0
28,0
29,0
33,0
36,0
39,0
43,0
280
370
490
590
750
890
1030
1270
1590
1840
2330
18,0
20,0
25,0
26,0
30,0
34,0
36,0
39,0
43,0
46,0
51,0
360
500
680
830
1090
1300
1530
1910
2360
2780
3570
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0114
Conductor diameter:
1,4
1,8
mm
Loop resistance:
11,9
7,2
/km
Insulation resistance:
10
10
Gkm
95
nF/km
600
600
V/DC
420
420
Veff/100Hz
2500
V/50Hz/1min
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
Filling:
Laminated sheath::
Armouring:
Protective cover:
PE (2Y), black
Design:
10 up to 20 cores ( 1,4)
German Railways
(DB)
(H95)
Operating voltage:
Temperature range:
during installation
-10 to +60
during operation
-40 to +60
10 up to 14 cores ( 1,8)
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
23
German Railways
PE-insulated, single core, with inductive protection
10-50
dimension of
conductor
1,4
OF
cable elements
Type
number of
cores
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
10x1x1,4
14x1x1,4
20x1x1,4
30x1x1,4
50x1x1,4
30x1x1,4
50x1x1,4
S
S
S
S
S
S
S
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
10
14
20
30
50
30
50
500
500
500
500
500
400
400
number of cores
filling
overall shield,
armouring
outer diameter
approx. mm
25,0
26,0
29,0
33,0
39,0
37,0
43,0
weight
approx. kg/km
1100
1220
1430
1820
2530
2530
3480
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0114
Conductor diameter:
1,4
mm
Loop resistance:
11,9
/km
Insulation resistance:
10
Gkm
nF/km
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
(H95)
Reduction factor:
acc. to DB AG 416.0116
Operating voltage:
600
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Filling:
Laminated sheath:
Screening:
during installation
-10 to +60
during operation
-40 to +60
Armouring:
Temperature range:
Protective cover:
PE (2Y), black
Design:
10 up to 50 cores ( 1,8)
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
24
German Railways
AJ-2YOF(L)2YDB2Y ..x1x1,8 S (H95)
10-50
dimension of
conductor
1,8
OF
cable elements
Type
number of
cores
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
AJ-2YOF(L)2YDB2Y
10x1x1,8
14x1x1,8
20x1x1,8
30x1x1,8
50x1x1,8
30x1x1,8
50x1x1,8
S
S
S
S
S
S
S
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
10
14
20
30
50
30
50
500
500
500
500
500
400
400
number of cores
filling
overall shield,
armouring
outer diameter
approx. mm
29,0
30,0
33,0
39,0
47,0
43,0
50,0
weight
approx. kg/km
1340
1560
1880
2460
3560
3380
4600
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0114
Conductor diameter:
1,8
mm
Loop resistance:
7,2
/km
Insulation resistance:
10
Gkm
nF/km
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
(H95)
Reduction factor:
acc. to DB AG 416.0116
Operating voltage:
600
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Filling:
Laminated sheath::
Screening:
during installation
-10 to +60
during operation
-40 to +60
Armouring:
German Railways
(DB)
Temperature range:
Protective cover:
PE (2Y), black
Design:
10 up to 50 cores ( 1,8)
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
25
German Railways
PE-insulated, core stranded, with reinforced sheath
0,9
1,4
1,8
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
A-2Y2YV
number of
cores
2x1x.. S
4x1x.. S
7x1x.. S
10x1x.. S
14x1x.. S
20x1x.. S
24x1x.. S
30x1x.. S
40x1x.. S
50x1x.. S
60x1x.. S
80x1x.. S
100x1x.. S
120x1x.. S
140x1x.. S
160x1x.. S
180x1x.. S
200x1x.. S
number of cores
outer diameter
approx. mm
outer diameter
approx mm
outer diameter
approx. mm
2
4
7
10
14
20
24
30
40
50
60
80
100
120
140
160
180
200
9,0
9,0
11,0
12,0
13,0
14,0
15,0
16,0
17,0
19,0
20,0
22,0
25,0
26,0
28,0
29,0
32,0
32,0
weight
approx. kg/km
60
80
120
150
180
240
280
340
430
520
600
770
960
1110
1290
1460
1640
1800
11,0
12,0
15,0
16,0
17,0
19,0
20,0
22,0
24,0
26,0
29,0
33,0
35,0
37,0
39,0
42,0
43,0
weight
approx. kg/km
140
200
280
370
490
570
690
900
1100
1300
1690
2120
2510
2900
3290
3690
4060
12,0
14,0
17,0
18,0
21,0
22,0
24,0
27,0
29,0
31,0
35,0
40,0
42,0
46,0
49,0
52,0
53,0
weight
approx. kg/km
200
300
420
560
760
900
1090
1430
1750
2070
2740
3390
4040
4670
5350
6010
6640
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0113
Conductor diameter:
0,9
1,4
1,8
mm
Conductor resistance:
28,9
11,9
7,2
/km
Insulation resistance:
10
10
10
Gkm
145
145
nF/km
(H115)
(H145)
(H145)
600
600
600
420
420
420
Veff/100Hz
2500
2500
2500
V/AC/1min
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
Operating voltage:
Dielectric strength (cond./cond.)
V/DC
190
/km
Insulation resistance:
dry cable
Gkm
drown cable
30
k abs.
Sheath:
nF/km
Design:
2500
V/50Hz/1min
Temperature range:
during installation
-10 up to +60
-40 up to +60
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
26
German Railways
A-2Y2YB2Y ..x1x.. S (H115/H145)
2-140
0,9
1,4
1,8
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
A-2Y2YB2Y
number of
cores
2x1x.. S
4x1x.. S
7x1x.. S
10x1x.. S
14x1x.. S
20x1x.. S
24x1x.. S
30x1x.. S
40x1x.. S
50x1x.. S
60x1x.. S
80x1x.. S
100x1x.. S
120x1x.. S
140x1x.. S
number of cores
outer diameter
approx. mm
outer diameter
approx mm
outer diameter
approx. mm
2
4
7
10
14
20
24
30
40
50
60
80
100
120
140
12,0
13,0
14,0
15,5
16,0
17,0
19,0
19,0
20,0
22,0
23,0
25,0
28,0
29,0
31,0
weight
approx. kg/km
130
150
170
220
280
340
400
460
550
680
770
970
1170
1350
1540
14,0
15,5
18,0
19,0
21,0
22,0
23,0
25,0
28,0
30,0
-
weight
approx. kg/km
210
290
380
470
620
740
860
1080
1320
1520
-
15,5
17,0
20,0
21,0
24,0
26,0
27,0
30,0
-
weight
approx. kg/km
290
410
540
720
950
1090
1300
1670
-
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0113
Conductor diameter:
0,9
1,4
1,8
mm
Conductor resistance:
28,9
11,9
7,2
/km
Insulation resistance:
10
10
10
Gkm
145
145
nF/km
(H115)
(H145)
(H145)
600
600
600
V/DC
420
420
420
Veff/100Hz
2500
2500
V/50Hz/1min
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
Operating voltage:
German Railways
(DB)
190
/km
dry cable
Gkm
drown cable
30
k abs.
Insulation resistance:
Sheath:
PE (2Y), black
nF/km
Armouring:
V/50Hz/1min
Temperature range:
Protective cover:
PE (2Y), black
during installation
-10 up to +60
Design:
-40 up to +60
4 up to 60 cores ( 1,4)
4 up to 40 cores ( 1,8)
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
27
German Railways
PE-insulated, single core, with inductive protection
dimension of
conductor
0,9
filling
overall shield,
armouring
cable elements
Type
number of
cores
10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
number of cores
outer diameter
approx. mm
600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
19,0
20,0
22,0
25,0
29,0
32,0
35,0
38,0
19,0
20,0
22,0
25,0
29,0
32,0
35,0
38,0
weight
approx. kg/km
620
780
940
1240
1600
2100
2550
2980
690
880
1070
1380
1770
2290
2750
3180
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0113
Conductor diameter:
0,9
mm
Conductor resistance:
28,9
/km
Insulation resistance:
10
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
Sheath:
Screening:
Gkm
nF/km
(H115)
Reduction factor:
acc. DB AG 416.0116
Operating voltage:
600
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Loop resistance:
PE (2Y), black
Insulation resistance:
190
/km
Gkm
dry cable
drown cable
30
k abs.
Armouring:
nF/km
Protective cover:
PE (2Y), black
2500
V/50Hz/1min
Temperature range:
during installation
-10 up to +60
-40 up to +60
Design:
Laying
28
German Railways
AJ-2Y2YDB2Y ..x1x1,4 S (H145)
10200
dimension of
conductor
1,4
filling
overall shield,
armouring
cable elements
Type
number of
cores
10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
50
80
120
160
200
outer diameter
approx. mm
600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
400
400
400
400
400
21,0
23,5
27,0
31,0
35,0
41,0
46,0
49,0
21,0
23,5
26,0
31,0
35,0
42,0
46,0
49,0
33,0
38,0
44,0
48,0
52,0
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
Sheath:
Screening:
number of cores
weight
approx. kg/km
840
1180
1460
2030
2800
3810
4760
5700
950
1300
1610
2220
3000
4080
5060
6020
2970
3960
5170
6280
7300
DB AG 416.0113
Conductor diameter:
1,4
mm
Conductor resistance:
11,9
/km
Insulation resistance:
10
Gkm
nF/km
(H145)
Reduction factor:
acc. DB AG 416.0116
Operating voltage:
600
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Loop resistance:
PE (2Y), black
Insulation resistance:
190
/km
dry cable
Gkm
drown cable
30
k abs.
Armouring:
nF/km
Protective cover:
PE (2Y), black
2500
V/50Hz/1min
Design:
Temperature range:
during installation
-10 up to +60
-40 up to +60
Laying
German Railways
(DB)
29
German Railways
PE-insulated, single core, with inductive protection
dimension of
conductor
1,8
filling
overall shield,
armouring
cable elements
Type
number of
cores
10
20
30
50
80
120
160
200
10
20
30
50
80
120
160
200
30
50
80
120
160
200
outer diameter
approx. mm
600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
400
400
400
400
400
400
23,0
27,0
30,0
36,0
41,0
48,0
54,0
58,0
23,0
27,0
30,0
36,0
42,0
49,0
55,0
59,0
32,0
38,0
44,0
51,0
57,0
61,0
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
number of cores
weight
approx. kg/km
950
1400
1770
2550
3620
5010
6350
7600
1050
1540
1930
2730
3860
5290
6660
7960
2560
3630
4850
6410
7910
9300
DB AG 416.0113
Conductor diameter:
1,8
mm
Conductor resistance:
7,2
/km
Insulation resistance:
10
Gkm
nF/km
(H145)
Reduction factor:
acc. DB AG 416.0116
Operating voltage:
600
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Loop resistance:
Sheath:
PE (2Y), black
Insulation resistance:
Screening:
dry cable
Gkm
drown cable
30
k abs.
190
/km
Armouring:
nF/km
Protective cover:
PE (2Y), black
2500
V/50Hz/1min
Design:
Temperature range:
during installation
-10 up to +60
-40 up to +60
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
30
German Railways
A-2Y2YV ..x1x.. S (H95)
10-50
1,4
1,8
dimension of
conductor
number of cores
filling
overall shield,
armouring
cable elements
Type
number of
cores
outer diameter
approx mm
weight
approx. kg/km
outer diameter
approx. mm
weight
approx. kg/km
10
14
20
30
50
16,0
18,0
20,0
24,0
29,0
320
420
570
800
1270
19,0
21,0
24,0
28,0
36,0
470
640
860
1240
2010
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
German Railways
(DB)
DB AG 416.0114
Conductor diameter:
1,4
1,8
mm
Conductor resistance:
11,9
7,2
/km
Insulation resistance:
10
10
Gkm
95
nF/km
600
600
V/DC
420
420
Veff/100Hz
2500
2500
V/50Hz/1min
(H95)
Operating voltage:
Dielectric strength (cond./cond.):
190
/km
Insulation resistance:
dry cable
Gkm
drown cable
30
k abs.
Sheath:
nF/km
Design:
2500
V/50Hz/1min
Temperature range:
Laying
during installation
-10 up to +60
-40 up to +60
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
31
German Railways
PE-insulated, single core, with rodent protection
1,4
1,8
dimension of
conductor
number of cores
filling
overall shield,
armouring
cable elements
Type
number of
cores
outer diameter
approx mm
weight
approx. kg/km
outer diameter
approx. mm
weight
approx. kg/km
10
14
20
18,0
20,0
22,0
450
570
750
21,0
23,0
-
650
820
-
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0114
Conductor diameter:
1,4
1,8
mm
Conductor resistance:
11.9
7.2
/km
Insulation resistance:
10
10
Gkm
Construction
95
nF/km
600
600
V/DC
420
420
Veff/100Hz
2500
V/50Hz/1min
Conductor:
Insulation:
PE (2Y)
Colour code:
(H95)
Operating voltage:
190
/km
dry cable
Gkm
drown cable
30
k abs.
Insulation resistance:
Sheath:
PE (2Y), black
nF/km
Armouring:
V/50Hz/1min
Temperature range:
Protective cover:
PE (2Y), black
during installation
-10 up to +60
Design:
10 up to 20 cores ( 1,4)
10 up to 14 cores ( 1,8)
-40 up to +60
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
32
German Railways
AJ-2Y2YDB2Y ..x1x1,4 S (H95)
10-50
dimension of
conductor
1,4
filling
overall shield,
armouring
cable elements
Type
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
number of
cores
10x1x1,4
14x1x1,4
20x1x1,4
30x1x1,4
50x1x1,4
30x1x1,4
50x1x1,4
S
S
S
S
S
S
S
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
10
14
20
30
50
30
50
22,0
24,0
27,0
30,0
35,0
32,0
38,0
Application
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
outer diameter
approx. mm
500
500
500
500
500
400
400
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
number of cores
weight
approx. kg/km
990
1130
1360
1680
2300
2350
3180
DB AG 416.0114
Conductor diameter:
1,4
mm
Conductor resistance:
11,9
/km
Insulation resistance:
10
Gkm
nF/km
(H95)
Reduction factor:
acc. DB AG 416.0116
Operating voltage:
600
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Loop resistance:
Sheath:
PE (2Y), black
Insulation resistance:
Screening:
dry cable
Gkm
drown cable
30
k abs.
190
/km
Armouring:
nF/km
Protective cover:
PE (2Y), black
2500
V/50Hz/1min
Design:
10 up to 50 cores ( 1,4)
Temperature range:
during installation
-10 up to +60
-40 up to +60
Laying
German Railways
(DB)
33
German Railways
PE-insulated, single core, with inductive protection
dimension of
conductor
1,8
filling
overall shield,
armouring
cable elements
Type
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
AJ-2Y2YDB2Y
number of
cores
10x1x1,8
14x1x1,8
20x1x1,8
30x1x1,8
50x1x1,8
30x1x1,8
50x1x1,8
S
S
S
S
S
S
S
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
(H95)
10
14
20
30
50
30
50
number of cores
outer diameter
approx. mm
500
500
500
500
500
400
400
25,0
27,0
30,0
34,0
42,0
37,0
44,0
weight
approx. kg/km
1380
1620
1990
2550
3670
3510
4780
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of direct current at an operating voltage 600 V and alternating current up to approximately 100 Hz during an actual operating voltage of
420 Veff.
Standard:
DB AG 416.0114
Conductor diameter:
1,8
mm
Conductor resistance:
7,2
/km
Insulation resistance:
10
Gkm
nF/km
Construction
Conductor:
Insulation:
PE (2Y)
Colour code:
(H95)
Reduction factor:
acc. DB AG 416.0116
Operating voltage:
600
V/DC
420
Veff/100Hz
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
Dielectric strength:
Loop resistance:
Sheath:
PE (2Y), black
Insulation resistance:
Screening:
190
/km
dry cable
Gkm
drown cable
30
k abs.
Armouring:
nF/km
Protective cover:
PE (2Y), black
2500
V/50Hz/1min
Design:
10 up to 50 cores ( 1,8)
Temperature range:
during installation
-10 up to +60
-40 up to +60
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
34
German Railways
A-2Y(L)2YV ..x4x.. S (H45)
2-80
0,9
1,4
dimension of
conductor
number of
double cores
filling
overall shield,
armouring
cable elements
Type
number of
double cores
outer diameter
approx mm
weight
approx. kg/km
outer diameter
approx. mm
weight
approx. kg/km
A-2Y(L)2YV 1x4x.. S
A-2Y(L)2YV 3x4x.. S
A-2Y(L)2YV 5x4x.. S
A-2Y(L)2YV 7x4x.. S
A-2Y(L)2YV 10x4x.. S
A-2Y(L)2YV 14x4x.. S
A-2Y(L)2YV 20x4x.. S
A-2Y(L)2YV 30x4x.. S
A-2Y(L)2YV 40x4x.. S
2
6
10
14
20
28
40
60
80
10,0
15,0
17,0
19,0
22,0
25,0
28,0
34,0
38,0
120
220
330
410
560
730
980
1410
1820
12,0
19,0
22,0
24,0
29,0
33,0
39,0
46,0
53,0
170
410
620
800
1090
1490
2040
2950
3900
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of alternating currents up to 90 kHz in systems, which require
a high symmetry against each other and outside disturbers as well as in relation to the earth potential.
Standard:
DB AG 416.0115
Conductor diameter:
0,9
1,4
mm
Loop resistance:
56,6
23,4
/km
Insulation resistance:
10
10
Gkm
45
45
nF/km
650
pF/500m
500
pF/500m
Construction
(H45)
Conductor:
Insulation:
PE (2Y)
Capacitance unbalance:k1
100% 650
Identification:
(at f=800Hz)
50%
cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked
with an open blue helix. 2 perforated cores ( 0,5 mm;
in cables with 7 quads)
wrapping of plastic tape
tinned copper wire ( 0,4 mm)
Sheath:
Design:
Laying
Usable for underground laying and drawing into conduits.
pF/500m
150
(at f=800Hz)
50%
Capacitance unbalance:e1/2
100% 1300
1300
pF/500m
pF/500m
150
1300
pF/500m
100% 3,3
2,6
db/km
FEXT:
100% 58
33
db/km
(at f=90kHz)
80%
(at f=800Hz)
db/km
62
Dielectric strength:
conductor/conductor
2500
2500
V/50Hz/1min
conductor/shield
2500
2500
V/50Hz/1min
Marking
German Railways
(DB)
190
/km
dry cable
Gkm
drown cable
30
k abs.
2500
V/50Hz/1min
during installation
-10 up to +60
-40 up to +60
Insulation resistance:
35
German Railways
PE-insulated, star-quads, with rodent protection
0,9
1,4
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
number of
double cores
outer diameter
approx mm
weight
approx. kg/km
outer diameter
approx. mm
weight
approx. kg/km
A-2Y(L)2YB2Y 1x4x.. S
A-2Y(L)2YB2Y 3x4x.. S
A-2Y(L)2YB2Y 5x4x.. S
A-2Y(L)2YB2Y 7x4x.. S
A-2Y(L)2YB2Y 10x4x.. S
A-2Y(L)2YB2Y 14x4x.. S
2
6
10
14
20
28
12,0
17,0
19,0
21,0
24,0
27,0
190
330
470
580
750
940
14,0
21,0
24,0
26,0
-
260
570
820
1020
-
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of alternating currents up to 90 kHz in systems, which require
a high symmetry against each other and outside disturbers as well as in relation to the earth potential.
Standard:
Construction
Conductor:
Insulation:
DB AG 416.0115
Conductor diameter:
0,9
1,4
mm
Loop resistance:
56,6
23,4
/km
Insulation resistance:
10
10
Gkm
45
45
nF/km
(H45)
PE (2Y)
Capacitance unbalance: k1
100%
650
Identification:
(at f=800Hz)
50%
150
500
cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked
with an open blue helix. 2 perforated cores ( 0,5 mm;
in cables with 7 quads)
(at f=800Hz)
150
pF/500m
1300 1300
pF/500m
ea1/2 100%
1300 1300
pF/500m
3.3
2.6
db/km
33
(at f=800Hz)
50%
100%
650
pF/500m
pF/500m
500
pF/500m
(at f=90kHz)
FEXT:
100%
58
(at f=90kHz)
80%
62
db/km
Sheath:
Armouring:
Protective cover:
PE (2Y), black
conductor/conductor
2500
2500
V/50Hz/1min
Design:
1 up to 14 quads ( 0,9)
conductor/shield
2500
2500
V/50Hz/1min
1 up to 7 quads ( 1,4)
db/km
Dielectric strength:
Laying
36
number of
double cores
190
/km
Insulation resistance:
dry cable
Gkm
drown cable
30
k abs.
2500
V/50Hz/1min
during installation
-10 up to +60
-40 up to +60
Marking
Temperature range:
German Railways
AJ-2Y(L)2YDB2Y ..x4x0,9 S (H45)
6-80
0,9
Type
number of
double cores
6
10
20
40
60
80
20
40
60
80
number of
double cores
dimension of
conductor
filling
cable elements
overall shield,
armouring
outer diameter
approx. mm
600
600
600
600
600
600
400
400
400
400
21,0
23,0
28,0
35,0
40,0
45,0
31,0
38,0
43,0
48,0
weight
approx. kg/km
800
1010
1430
2130
2800
3580
2250
3240
4080
4800
Application
for general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of alternating currents up to 90 kHz in systems, which require
a high symmetry against each other and outside disturbers as well as in relation to the earth potential.
Standard:
DB AG 416.0115
Conductor diameter:
0,9
mm
Loop resistance:
56,6
/km
Insulation resistance:
10
Gkm
45
nF/km
Construction
Conductor:
Insulation:
PE (2Y)
Identification:
cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked
with an open blue helix. 2 perforated cores ( 0,5 mm;
in cables with 7 quads)
wrapping of plastic tape
tinned copper wire ( 0,4 mm)
Sheath:
Screening:
Armouring:
Protective cover:
PE (2Y), black
Design:
Laying
Usable for underground laying and drawing into conduits.
Marking
1st line: SIGNAL <meter> VDE-Index No. <type> PENGG KABEL
2nd line (if cable >20mm): SIGNAL
German Railways
(DB)
(H45)
Capacitance unbalance: k1
100%
650
(at f=800Hz)
50%
150
pF/500m
500
pF/500m
pF/500m
(at f=800Hz)
50%
150
pF/500m
100%
1300
pF/500m
ea1/2 100%
1300
pF/500m
100%
3.3
db/km
FEXT:
100%
58
db/km
(at f=90kHz)
80%
62
db/km
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
190
/km
dry cable
Gkm
drown cable
30
k abs.
2500
V/50Hz/1min
during installation
-10 up to +60
-40 up to +60
(at f=800Hz)
Dielectric strength:
37
German Railways
PE-insulated, star quads, with inductive protection
1,4
Type
number of
double cores
6
10
20
40
60
80
10
20
40
60
80
dimension of
conductor
filling
cable elements
overall shield,
armouring
outer diameter
approx. mm
500
500
500
500
500
500
400
400
400
400
400
25,0
29,0
37,0
47,0
54,0
61,0
31,0
39,0
49,0
56,0
63,0
weight
approx. kg/km
1350
1760
2620
4040
5330
6550
2470
3610
5260
6690
8070
Application
For general use in protection systems (unless the application of special cable
of safety engineering, e.g. Indusi connection cables, is specified), preferably
for transmission of alternating currents up to 90 kHz in systems, which require
a high symmetry against each other and outside disturbers as well as in relation to the earth potential.
Standard:
DB AG 416.0115
Conductor diameter:
1,4
mm
Loop resistance:
23,4
/km
Insulation resistance:
10
Gkm
Construction
45
nF/km
(H45)
Conductor:
Insulation:
PE (2Y)
Capacitance unbalance: k1
100%
650
pF/500m
Identification:
(at f=800Hz)
Capacitance unbalance: k9-12 100%
500
pF/500m
cores twisted to quads, quads cabled together in concentric layers, the tracer quad in each layer is marked
with an open blue helix. 2 perforated cores ( 0,5 mm;
in cables with 7 quads)
(at f=800Hz)
Capacitance unbalance: e1/2 100%
1300
pF/500m
ea1/2 100%
1300
pF/500m
100%
2,6
db/km
100%
33
db/km
Sheath:
Screening:
(at f=800Hz)
(at f=90kHz)
FEXT
(at f=90kHz)
Dielectric strength:
conductor/conductor
2500
V/50Hz/1min
Protective cover:
PE (2Y), black
conductor/shield
2500
V/50Hz/1min
Design:
190
/km
dry cable
Gkm
drown cable
30
k abs.
2500
V/50Hz/1min
during installation
-10 up to +60
-40 up to +60
Armouring:
Laying
Usable for underground laying and drawing into conduits.
38
number of
double cores
Insulation resistance:
Marking
Temperature range:
German Railways
PE-foam skin insulated, star quads, reinforced sheath A-02YSTF(L)2YV ..x4x0,9 STI TNP 02
mutual capacitance
10-60
TF
dimension of
copper conductor
0,9
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
filling
overall shield,
armouring
cable elements
Type
number of
double cores
number of
double cores
outer diameter
approx. mm
weight
approx. kg/km
10
20
32
38
48
60
20,0
28,0
33,0
35,0
41,0
43,0
300
570
790
940
1170
1390
Application
The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.
Standard:
Arcor TNP 02
Conductor diameter:
0,9
mm
Loop resistance:
56,6
/km
Resistance difference:
0,30
/km
Construction
Conductor:
Insulation resistance:
Gkm
Insulation:
10
Mutual capacitance:
nF/km
Colour code :
a core: YE
34
Capacitance unbalance:
k1
110
pF/km
k9-12
110
pF/km
ea1/2
1300
pF/km
b core: RD
c core: GN
d core: BU
Cable make up:
Sheath:
Marking
German Railways
(DB)
C34
Attenuation:
0,6
db/km
Operating voltage:
800 Hz
250
Veff
Near-end crosstalk:
45
dB/abs.
Far-end crosstalk:
45
dB/km
Dielectric strength:
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
190
/km
Insulation resistance:
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Dielectric strength:
39
German Railways
PE-foam skin insulated,star quads,with reinforced sheath
C34 C36
0.9
mutual capacitance
1.4
16-66
dimension of
conductor
TF
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
A-02YSTF(L)2YV
1x4x1,4
2x4x1,4
3x4x1,4
4x4x1,4
5x4x1,4
3x4x1,4
filling
overall shield,
armouring
cable elements
Type
number of
double cores
number of
double cores
outer diameter
approx. mm
weight
approx. kg/km
16
26
30
34
42
66
25,0
34,0
35,0
37,0
40,0
47,0
510
820
940
1080
1300
1690
Application
The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.
Standard:
Arcor TNP 02
Conductor diameter:
0,9
1,4
mm
Construction
Loop resistance:
56,6
23,4
/km
0,30
0,20
/km
Gkm
Conductor:
Resistance difference:
Insulation:
Insulation resistance:
Colour code :
Sheath:
a core: YE
L>200m
10
10
b core: RD
100m L 200m
25
25
Gkm
c core: GN
L<100m
30
30
Gkm
34
36
nF/km
k1
110
110
pF/km
k9-12
110
110
pF/km
ea1/2
1300
1300
pF/km
db/km
d core: BU
Mutual capacitance:
Capacitance unbalance:
Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol
Attenuation:
800 Hz
0,6
0,4
Operating voltage:
250
250
Veff
Near-end crosstalk:
45
45
dB abs.
Far-end crosstalk:
45
45
dB/km
Dielectric strength:
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
190
/km
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Insulation resistance:
Dielectric strength:
40
German Railways
C34
0,9
mutual capacitance
10
number of
double cores
dimension of
copper conductor
TF
filling
overall shield,
armouring
cable elements
Type
number of
double cores
outer diameter
approx. mm
weight
approx. kg/km
10
22,2
521
Application
The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.
Standard:
Arcor TNP 02
Conductor diameter:
0,9
mm
Construction
Loop resistance:
56,6
/km
Conductor:
Resistance difference:
0,30
/km
Insulation:
Insulation resistance:
10
Gkm
Colour code :
a core: YE
Mutual capacitance:
34
nF/km
b core: RD
Capacitance unbalance:
c core: GN
k1
110
pF/km
d core: BU
k9-12
110
pF/km
ea1/2
1300
pF/km
Sheath:
Armouring:
Protective cover:
Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol
German Railways
(DB)
PE-foam skin insulated, star quads, with rodent protection A-02YSTF(L)2YB2Y 5x4x0,9 STI TNP 02
Attenuation:
0,6
db/km
Operating voltage:
800 Hz
250
Veff
Near-end crosstalk:
45
dB/abs.
Far-end crosstalk:
45
dB/km
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Dielectric strength:
190
/km
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Insulation resistance:
Dielectric strength:
41
German Railways
PE-foam skin insulated, star quads, with rodent protection
C34
0.9
mutual capacitance
10
number of
double cores
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
number of
double cores
outer diameter
approx. mm
weight
approx. kg/km
10
23,2
495,1
Application
The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.
Standard:
Arcor TNP 02
Conductor diameter:
0,9
mm
Loop resistance:
56,6
/km
Resistance difference:
0,30
/km
Construction
Conductor:
Insulation:
L>200m
10
Gkm
Colour code :
a core: YE
100m L 200m
25
Gkm
b core: RD
L<100m
30
Gkm
34
nF/km
Insulation resistance:
c core: GN
Mutual capacitance:
d core: BU
Capacitance unbalance:
Sheath:
Armouring:
Protective cover:
k1
110
pF/km
k9-12
110
pF/km
ea1/2
1300
pF/km
0,6
db/km
Attenuation:
800 Hz
Operating voltage:
250
Veff
Near-end crosstalk:
45
dB abs.
Marking
Far-end crosstalk:
45
dB/km
Dielectric strength:
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
190
/km
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Insulation resistance:
Dielectric strength:
42
German Railways
AJ-02YSTF(L)2YDB2Y ..x4x0,9 STI A TNP 02
C34
mutual capacitance
20-60
dimension of
copper conductor
0,9
TF
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
10x4x0,9
16x4x0,9
19x4x0,9
24x4x0,9
30x4x0,9
STI
STI
STI
STI
STI
TNP
TNP
TNP
TNP
TNP
02
02
02
02
02
filling
overall shield,
armouring
cable elements
Type
number of
double cores
number of
double cores
outer diameter
approx. mm
weight
approx. kg/km
20
32
38
48
60
37,0
41,0
43,0
49,0
52,0
1730
2110
2260
2750
3060
Application
The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.
Standard:
Arcor TNP 02
Conductor diameter:
0,9
mm
Construction
Loop resistance:
56,6
/km
Conductor:
Resistance difference:
0,30
/km
Insulation:
Insulation resistance:
10
Gkm
Colour code :
a core: YE
Mutual capacitance:
34
nF/km
b core: RD
Capacitance unbalance:
c core: GN
k1
110
pF/km
d core: BU
k9-12
110
pF/km
ea1/2
1300
pF/km
Sheath:
Screening:
Armouring:
Protective cover:
Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol
German Railways
(DB)
Attenuation:
0,6
db/km
Operating voltage:
800 Hz
250
Veff
Near-end crosstalk:
45
dB/abs.
Far-end crosstalk:
45
dB/km
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Dielectric strength:
190
/km
Insulation resistance:
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Dielectric strength:
Reduction factor:
43
German Railways
PE-foam skin insulated, quads, inductive protection
C34 C36
1.4
0.9
mutual capacitance
16-66
dimension of
conductor
TF
number of
double cores
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
AJ-02YSTF(L)2YDB2Y
1x4x1,4 /
2x4x1,4 /
3x4x1,4 /
4x4x1,4 /
5x4x1,4 /
3x4x1,4 /
7x4x0.9
11x4x0.9
12x4x0.9
13x4x0.9
16x4x0.9
30x4x0.9
outer diameter
approx. mm
16
26
30
34
42
66
filling
overall shield,
armouring
cable elements
Type
number of
double cores
34.0
42.0
44.0
46.0
48.0
56.0
weight
approx. kg/km
1490
2030
2140
2330
2580
3300
Application
The cable is designed for use as railway signalling cable for long distances.
Usable for underground laying and drawing into conduits.
Standard:
Arcor TNP 02
Conductor diameter:
0,9
1,4
mm
Construction
Loop resistance:
56,6
23,4
/km
0,30
0,20
/km
Conductor:
Resistance difference:
Insulation:
Insulation resistance:
Colour code :
a core: YE
L>200m
10
10
Gkm
b core: RD
100m L 200m
25
25
Gkm
c core: GN
L<100m
30
30
Gkm
34
36
nF/km
d core: BU
Mutual capacitance:
Capacitance unbalance:
Sheath:
Screening:
Armouring:
Protective cover:
Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol
110
110
pF/km
k9-12
110
110
pF/km
ea1/2
1300
1300
pF/km
db/km
Attenuation:
800 Hz
0,6
0,4
Operating voltage:
250
250
Veff
Near-end crosstalk:
45
45
dB abs.
Far-end crosstalk:
45
45
dB/km
Dielectric strength:
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
190
/km
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Insulation resistance:
Dielectric strength:
Reduction factor:
44
German Railways
A-02YS(L)2YV x4x0,7 mm STI TNP 03
C34
#
0,7
mutual capacitance
6-14
number of
double cores
dimension of
copper conductor
filling
cable elements
overall shield,
armouring
Type
number of
double cores
outer diameter
approx. mm
weight
approx. kg/km
6
10
14
20,0
24,0
26,0
290
420
510
Application
The cable is designed for use as railway signalling cable for long distances, with
high resistance against vibrations. The cable is fixed directly at the rail.
Standard:
Conductor cross section:
0,7
mm
Construction
Loop resistance:
56,6
/km
Arcor TNP 03
Conductor:
Resistance difference:
0,30
/km
Insulation:
Insulation resistance:
10
Gkm
a core: YE
Mutual capacitance:
34
nF/km
b core: RD
Capacitance unbalance:
Colour code :
Screening/sheath:
c core: GN
k1
110
pF/km
d core: BU
k9-12
110
pF/km
ea1/2
1300
pF/km
Marking
German Railways
(DB)
Attenuation:
800 Hz
Operating voltage:
0,6
db/km
250
Veff
Near-end crosstalk:
45
dB/abs.
Far-end crosstalk:
45
dB/km
Dielectric strength:
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
190
/km
Insulation resistance:
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
95
/km
Dielectric strength:
45
German Railways
PE-foam skin insulated, star-quads, with rodent protection
C34
#
0,7
Type
mutual capacitance
number of
double cores
dimension of
conductor
filling
cable elements
overall shield,
armouring
number of
double cores (DC)
A-02YS(L)2YB2Y 3x4x0,7mm
A-02YS(L)2YB2Y 5x4x0,7mm
A-02YS(L)2YB2Y 7x4x0,7mm
6-14
outer diameter
approx. mm
6
10
14
24,0
28,0
30,0
weight
approx. kg/km
500
660
790
Application
The cable is designed for use as railway signalling cable for long distances, with
high resistance against vibrations. The cable is fixed directly at the rail.
Standard:
Arcor TNP 03
Conductor diameter:
0,7
mm
Construction
Loop resistance:
56,6
/km
0,30
/km
Conductor:
Resistance difference:
Insulation:
Insulation resistance:
Colour code :
Sheath:
a core: YE
L>200m
10
Gkm
b core: RD
100m L 200m
25
Gkm
c core: GN
L<100m
30
Gkm
34
nF/km
k1
110
pF/km
k9-12
110
pF/km
ea1/2
1300
pF/km
d core: BU
Mutual capacitance:
Capacitance unbalance:
Armouring:
Protective cover:
Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol
Attenuation:
0,6
db/km
Operating voltage:
800 Hz
250
Veff
Near-end crosstalk:
45
dB abs.
Far-end crosstalk:
45
dB/km
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Dielectric strength:
190
/km
dry cable
Gkm
drown cable
30
k. abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
95
/km
Insulation resistance:
Dielectric strength:
46
German Railways
A-02YS(L)2Y(SR)2Y x4x0,7 mm STI TNP 03
number of
double cores
C34
mutual capacitance
#
0,7
dimension of
copper conductor
filling
cable elements
overall shield,
armouring
6-14
Type
number of
double cores
outer diameter
approx. mm
weight
approx. kg/km
6
10
14
24,0
28,0
30,0
500
660
790
Application
The cable is designed for use as railway signalling cable for long distances, with
high resistance against vibrations. The cable is fixed directly at the rail.
Standard:
Conductor cross section:
0,7
mm
Construction
Loop resistance:
56,6
/km
Arcor TNP 03
Conductor:
Resistance difference:
0,30
/km
Insulation:
Insulation resistance:
10
Gkm
Colour code :
a core: YE
Mutual capacitance:
34
nF/km
b core: RD
Capacitance unbalance:
c core: GN
k1
110
pF/km
d core: BU
k9-12
110
pF/km
ea1/2
1300
pF/km
Attenuation:
Sheath:
0,6
db/km
Operating voltage:
250
Veff
Armouring:
Near-end crosstalk:
45
dB/abs.
Protective cover:
Far-end crosstalk:
45
dB/km
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol
German Railways
(DB)
800 Hz
Dielectric strength:
190
/km
Insulation resistance:
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
95
/km
Dielectric strength:
47
German Railways
PE-foam skin insulated, star-quads, with strain relief elements
C34
0.9
Type
mutual capacitance
filling
cable elements
overall shield,
armouring
outer diameter
approx. mm
10
14
20
24
32
21,1
22,8
27,1
28,4
31,9
Application
The cable is designed for use as railway signalling cable for long distances, only
for overground laying and mounting poles.
Standard:
Construction
number of
double cores
dimension of
conductor
number of
double cores
A-02YS2Y(ST)(ZN)2Y 5x4x0,9mm
A-02YS2Y(ST)(ZN)2Y 7x4x0,9mm
A-02YS2Y(ST)(ZN)2Y 10x4x0,9mm
A-02YS2Y(ST)(ZN)2Y 12x4x0,9mm
A-02YS2Y(ST)(ZN)2Y 16x4x0,9mm
10-32
weight
approx. kg/km
354,5
434,1
569,3
660,1
839,8
Arcor TNP 04
Conductor diameter:
0,9
mm
Loop resistance:
56,6
/km
Resistance difference:
0,30
/km
Conductor:
Insulation:
L>200m
10
Gkm
Colour code :
a core: YE
100m L 200m
25
Gkm
b core: RD
L<100m
30
Gkm
34
nF/km
c core: GN
Mutual capacitance:
d core: BU
Capacitance unbalance:
Sheath:
Screening:
Strain relief/
Protective cover:
Insulation resistance:
Marking
k1
110
pF/km
k9-12
110
pF/km
ea1/2
1300
pF/km
0,6
db/km
Attenuation:
800 Hz
Operating voltage:
250
Veff
Near-end crosstalk:
45
dB abs.
Far-end crosstalk:
45
dB/km
Dielectric strength:
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
190
/km
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
140
/km
Insulation resistance:
Dielectric strength:
48
German Railways
A-02YSF(L)2YV 2x4x1,4 / 2x4x0,9 STI TNP 06
C34 C36
mutual capacitance
0.9
dimension of
conductor
1.4
number of
double cores
outer diameter
approx. mm
filling
overall shield,
armouring
cable elements
Type
number of
double cores
weight
approx. kg/km
24.0
540
Application
The cable is designed for use as railway signalling cable, preferable for the
connection of railway connection boxes.
Usable for underground laying and drawing into conduits.
Standard:
Arcor TNP 06
Conductor diameter:
0,9
1,4
mm
Loop resistance:
56,6
23,4
/km
Construction
Resistance difference:
0,30
0,20
/km
Conductor:
Insulation:
L>200m
10
10
Gkm
Colour code :
a core: YE
100m L 200m
25
25
Gkm
b core: RD
L<100m
30
30
Gkm
34
36
nF/km
Sheath:
Insulation resistance:
c core: GN
Mutual capacitance:
d core: BU
Capacitance unbalance:
German Railways
(DB)
k1
110
110
pF/km
k9-12
110
110
pF/km
ea1/2
1300
1300
pF/km
db/km
Attenuation:
800 Hz
0,6
0,4
Operating voltage:
250
250
Marking
Veff
Near-end crosstalk:
45
45
dB abs.
Far-end crosstalk:
45
45
dB/km
Dielectric strength:
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
190
/km
Insulation resistance:
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Dielectric strength:
49
German Railways
PE-foam skin insulated, star-quads, with rodent protection
C34
0.9
mutual capacitance
number of
double cores
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
number of
double cores (DC)
A-02YSF(L)2Y(SR)2Y
3x4x0,9mm
outer diameter
approx. mm
20,0
weight
approx. kg/km
350
Application
The cable is designed for use as railway signalling cable, preferable for theconnection of railway connection boxes. Useable for underground laying and
drawing into conduits.
Standard:
Arcor TNP 06
Conductor diameter:
0,9
mm
Loop resistance:
56,6
/km
Construction
Resistance difference:
0,30
/km
Conductor:
Insulation:
L>200m
10
Gkm
Colour code :
a core: YE
100m L 200m
25
Gkm
b core: RD
L<100m
30
Gkm
34
nF/km
k1
110
pF/km
k9-12
110
pF/km
ea1/2
1300
pF/km
Sheath:
Insulation resistance:
c core: GN
Mutual capacitance:
d core: BU
Capacitance unbalance:
Attenuation:
0,6
db/km
Operating voltage:
250
Veff
Near-end crosstalk:
45
dB abs.
Marking
Far-end crosstalk:
45
dB/km
Dielectric strength:
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Armouring:
Protective cover:
800 Hz
190
/km
Insulation resistance:
dry cable
Gkm
drown cable
30
k abs.
conductor/conductor
500
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
Dielectric strength:
50
German Railways
A-2Y(L)2YB2Y 1x4x
mutual capacitance
1,4
dimension of
copper conductor
1,53
number of
double cores
filling
overall shield,
armouring
cable elements
Type
number of
double cores
outer diameter
approx. mm
weight
approx. kg/km
A-2Y(L)2YB2Y 1x4x1,4
A-2Y(L)2YB2Y 1x4x1,53
2
2
14,0
18,0
260
350
Application
The cable is designed for use in signal systems (unless the application of special cables of signaltechnique is required), preferably for transmission of alternating currents in systems which needs a high symmetry against each other.
Standard:
DB AG 416.0120
Conductor diameter:
1,4
1,53
mm
Loop resistance:
23,4
19,8
/km
Construction
Insulation resistance:
10
52
43
nF/km
k1
650
240
pF/km
ea1/2
1300
650
pF/km
Conductor:
Mutual capacitance:
Insulation:
PE (2Y)
Capacitance unbalance:
Colour code :
a core: transparent
b core: transparent with one ring mark every 17 mm
c core: transparent with two ring marks every 34 mm
Operating voltage:
Gkm
DC
600
600
AC
420
420
V/100 Hz
Screening:
Near-end crosstalk:
55
60
dB
4,2
dB/km
120+/-10%
120+/-10%
Armouring:
Protective cover:
Marking
SIGNAL / Eurobalise (alternating every 25 cm) - type - VDE reg. nr. - PENGG
KABEL - <meter>
German Railways
(DB)
Attenuation:
560 kHz
Impedance:
200 - 600 kHz
Dielectric strength:
conductor/conductor
2500
2500
V/50Hz/1min
conductor/shield
2500
2500
V/50Hz/1min
51
German Railways
PE-insulated, star-quads, with inductive protection
AJ-2Y(L)2YDB2Y 1x4x1,53
C43
1.53
Type
number of
double cores
AJ-2Y(L)2YDB2Y 1x4x1,53
AJ-2Y(L)2YDB2Y 1x4x1,53
AJ-2Y(L)2YDB2Y 1x4x1,53
2
2
2
mutual capacitance
number of
double cores
dimension of
conductor
filling
cable elements
overall shield,
armouring
600
500
400
outer diameter
approx. mm
22,0
22,0
24,0
weight
approx. kg/km
740
830
1330
Application
The cable is designed for use in signal systems (unless the application of special cables of signaltechnique is required), preferably for transmission of alternating currents in systems which needs a high symmetry against each other.
Standard:
DB AG 416.0120
Conductor diameter:
1,53
mm
Loop resistance:
Construction
19,8
/km
Insulation resistance:
10
Gkm
43
nF/km
k1
240
pF/km
ea1/2
650
pF/km
Conductor:
Mutual capacitance:
Insulation:
PE (2Y)
Capacitance unbalance:
Colour code :
a core: transparent
b core: transparent with one ring mark every 17 mm
c core: transparent with two ring marks every 34 mm
Operating voltage:
DC
600
AC
V/100 Hz
1st Screening:
420
60
dB
8,8 kHz
0,8
dB/km
280 kHz
3,0
dB/km
560 kHz
4,2
dB/km
1,8 MHz
8,0
dB/km
8,8 kHz
147+/-15%
120+/-10%
1,8 MHz
120+/-10%
2nd Screening:
Armouring:
Protective cover:
Marking
SIGNAL / Eurobalise (alternating every 25 cm) - type - VDE reg. nr. - PENGG
KABEL - <meter>
Impedance:
Reduction factor:
acc. to DB AG 416.0120
Temperature range
52
during operation
-40 up to +60
during installation
-10 up to +60
German Railways
A-2YF(L)2Y ..x4x0,4 STIII BD
C50
0.4
mutual capacitance
6200
number of
double cores
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
A-2YF(L)2Y
number of
double cores
6x2x0.4
10x2x0.4
20x2x0.4
30x2x0.4
40x2x0.4
50x2x0.4
70x2x0.4
100x2x0.4
150x2x0.4
200x2x0.4
STIII
STIII
STIII
STIII
STIII
STIII
STIII
STIII
STIII
STIII
BD
BD
BD
BD
BD
BD
BD
BD
BD
BD
outer diameter
approx. mm
6
10
20
30
40
50
70
100
150
200
9.5
10.5
12.5
15.0
16.5
17.5
20.0
23.0
27.5
31.0
weight
approx. kg/km
80
105
160
230
285
340
445
600
910
1165
Application
The cable is designed for transmission of railway station signals. Usable for
underground laying and drawing into conduits.
Standard:
Conductor diameter:
0,4
mm
Construction
300
/km
Gkm
Dlk 1.013.151
Conductor:
Insulation resistance:
Insulation:
PE (2Y)
Colour code :
a core: transparent
100%
50
nF/km
95%
48
nF/km
Capacitance unbalance:
k1
100%
800
pF/300m
k1
98%
400
pF/300m
k9-12 100%
300
pF/300m
k9-12 98%
100
pF/300m
1,49
dB/km
2000
V/50Hz/2min
Sheath:
German Railways
(DB)
Attenuation:
800 Hz
Dielectric strength:
conductor/shield
Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol
53
German Railways
PE-foam skin insulated, star-quads
C42 C42
0.8
0.6
mutual capacity
6200
number of
double cores
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
A-02YSF(L)2Y
6x2x..
10x2x..
20x2x..
30x4x..
40x4x..
50x4x..
70x4x..
100x4x..
200x4x..
number of
double cores
outer diameter
approx mm
weight
approx. kg/km
outer diameter
approx. mm
weight
approx. kg/km
6
10
20
30
40
50
70
100
200
10,3
11,8
15,3
17,6
19,6
21,3
24,8
28,6
39,2
107,5
147,3
255,2
350,6
443,2
532,1
730,2
991,7
1876,5
13,2
15,3
20,0
22,7
25,4
28,2
32,3
38,8
51,8
176,9
252,0
450,3
601,6
755,1
952,6
1273,9
1823,4
3301,0
Application
The cable is designed for transmission of railway station signals. Usable for
underground laying and drawing into conduits.
Standard:
Dlk 1.013.151
Conductor diameter:
0,6
0,8
mm
Construction
130
73,2
/km
Gkm
Conductor:
Insulation resistance:
Insulation:
Colour code :
a core: transparent
100%
42
42
nF/km
95%
40
40
nF/km
80%
38
38
nF/km
k1
100%
800
800
pF/300m
98%
400
400
pF/300m
k9-12 100%
300
300
pF/300m
k9-12 98%
100
100
pF/300m
0,91
0,69
dB/km
Sheath:
Cable short mark:
Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol
54
Capacitance unbalance:
Attenuation:
800 Hz
Dielectric strength
conductor/conductor
500
500
V/50Hz/2min
conductor/shield
200
2000
V/50Hz/2min
225
225
German Railways
AJ-02YSF(L)2YDB2Y ..x2x0,8 STIII BD
C42
0,8
mutual capacitance
6200
number of
double cores
dimension of
copper conductor
filling
overall shield,
armouring
cable elements
Type
number of
double cores
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
AJ-02YSF(L)2YDB2Y
10x2x0.8 STIII BD
20x2x0.8 STIII BD
30x2x0.8 STIII BD
40x2x0.8 STIII BD
50x2x0.8 STIII BD
70x2x0.8 STIII BD
100x2x0.8 STIII BD
200x2x0.8 STIII BD
outer diameter
approx. mm
10
20
30
40
50
70
100
200
24,2
29,1
31,9
35,3
38,7
45,0
50,2
66,3
weight
approx. kg/km
1070,8
1486,0
1821,7
2203,5
2525,8
3626,5
4517,7
6985,5
Application
The cable is designed for transmission of railway station signals. Usable for
underground laying and drawing into conduits.
Standard:
Dlk 1.013.151
Conductor diameter:
0,8
mm
Construction
73,2
/km
Gkm
Conductor:
Insulation resistance:
Insulation:
Colour code :
a core : transparent
100%
42
nF/km
95%
40
nF/km
80%
38
nF/km
Capacitance unbalance
k1
100%
800
pF/300m
k1
98%
400
pF/300m
300
pF/300m
Sheath:
k9-12 100%
100
pF/300m
Screening:
k9-12 98%
Armouring:
0,69
dB/km
Protective Cover:
conductor/conductor
500
V/50Hz/2min
conductor/shield
2000
V/50Hz/2min
225
Reduction factor:
German Railways
(DB)
Attenuation:
800 Hz
Dielectric strength
Marking
1. line: handset symbol - <meter>
2. line: ( >20mm) handset symbol
55
German Railways
Note
56
MD4 x4x0,8
page 59
ZPFU- ...px1
page 60
ZUG-S ...P...
page 61
ZUT-S ...P...
page 62
4D...
page 63
French Railways
(SNCF)
ZPAU -px
57
French Railways
PE insulated, pairs, with inductive protection
ZPAU -px
mutual capacity
#
2,5
#
1
1-56
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
number of
double cores
ZPAU 1px2,5
ZPAU 4px1
ZPAU 7px1
ZPAU 14px1
ZPAU 21px1
ZPAU 28px1
ZPAU 56px1
outer diameter
approx. mm
1
4
7
14
21
28
56
Application
The cable is designed for the connection of the control center to the equipment shelters.
Construction
Conductor:
Insulation:
PE
Colour code:
a core: transparent
b core: BK - BE - YE - RD - GN
763
620
944
1384
1731
2122
3290
SNCF CT 445
2,5
mm
Conductor resistance:
18,1
7,41
/km
Insulation resistance:
Gkm
Mutual capacitance:
1000 (+/-200) Hz
nF/km
55
8,9 kHz
45
nF/km
300
pF/500m
Capacitance unbalance:
200
Reduction factor:
Sheath:
PE, transparent
Screening:
45 kHz
Armouring:
560 kHz
Protective cover:
PE, black
Attenuation:
dB/km
2,5
3,8
dB/km
Impedance:
800Hz
58
weight
approx. kg/km
21,2
23,8
26,7
31,0
35,5
39,5
49,5
Marking
type - CT 445 - PENGG KABEL - month/year of production - <meter> RESEAU FERRE DE FRANCE
number of
double cores
120+/-10
8,9 kHz
130+/-10
Dielectric strength:
conductor/conductor
3000
V/DC/3min
conductor/shield
3000
V/DC/3min
French Railways
PE-foam skin insulated, star quads, with inductive protection
mutual capacity
0.8
14-56
dimension of
conductor
MD4
MD4
MD4
MD4
number of
double cores
7x4x0,8
14x4x0,8
21x4x0,8
28x4x0,8
outer diameter
approx. mm
14
28
42
56
Application
The cable is designed for long distance telecommunications alongside railway
lines.
Construction
Conductor:
Insulation:
PE-foam skin
Colour code:
a core: GY - OG
b core: WH - YE - BK - GN - BU - BN - RD
c core: VT
23,7
28,5
33,3
34,0
Sheath:
Conductor diameter:
0,8
mm
Conductor resistance:
35,6
/km
Insulation resistance:
15
Gkm
49
nF/km
max
51
nF/km
min
46
nF/km
50
pF/1450m
max
340
pF/1450m
30
pF/1450m
340
pF/1450m
200
pF/1450m
1025
pF/1450m
Capacitance unbalance:
k1
k9-12
ea1/2
Protective cover:
PE, black
Marking
<meter> - "RFF" - type - "2328" - "ed4"- PENGG KABEL - year of production
773
1277
1787
1913
cores twisted to pairs, pairs cabled together to a bundel, bundels stranded to the cable core, wrapping with
tape
Armouring:
weight
approx. kg/km
Standard:
d core: BU - BN - RD - WH - YE - BK - GN
Cable make up:
filling
overall shield,
armouring
cable elements
Type
number of
double cores
French Railways
(SNCF)
C49
MD4 x4x0,8
max
max
Reduction factor:
Attenuation:
1MHz
15,9
dB/km
520+/-10%
/km
conductor/conductor
1500
V/DC/1min
conductor/shield
3000
V/DC/1min
conductor/shield
3750
V/DC/3sek
Impedance:
800Hz
Dielectric strength:
59
French Railways
PE insulated, pairs, with armouring
ZPFU -px1
C 55
#
1
Type
Construction
Conductor:
Insulation:
PE
Colour code:
a core: transparent
b core: BK - BE - YE - RD - GN
Sheath:
Armouring:
Protective cover:
PE, black
Marking
type - CT 445 - PENGG KABEL - month/year of production - <meter> - PROPRIETE RFF
60
number of
double cores
filling
cable elements
overall shield,
armouring
outer diameter
approx. mm
1
2
4
7
14
21
28
56
Application
The cable is designed for the connection of the control center to the equipment shelters.
1-56
dimension of
conductor
number of
double cores
ZPFU 1px1
ZPFU 1px1
ZPFU 4px1
ZPFU 7px1
ZPFU 14px1
ZPFU 21px1
ZPFU 28px1
ZPFU 56px1
mutual capacity
12,5
13,6
17,3
20,8
27,0
29,9
33,4
43,8
weight
approx. kg/km
186
248
369
695
1083
1363
1668
2752
SNCF CT 445
mm
Conductor resistance:
18,1
/km
Insulation resistance:
Gkm
55
nF/km
200
pF/500m
2,5
dB/km
120+/-10
conductor/conductor
3000
V/DC/3min
conductor/shield
3000
V/DC/3min
Mutual capacitance:
1000 (+/-200) Hz
Capacitance unbalance:
Attenuation:
45 kHz
Impedance:
800Hz
Dielectric strength:
French Railways
PVC insulated, pair stranded
ZUG-S P
mutual capacity
#
1
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
ZUG-S
ZUG-S
ZUG-S
ZUG-S
ZUG-S
number of
double cores
1P1
3P1
6P1
12P1
28P0,38
Application
The cable is designed for connection of railway network equipments in the
traffic control center.
Construction
Conductor:
Insulation:
PVC
Colour code:
outer diameter
approx. mm
1
3
6
12
28
number of
double cores
weight
approx. kg/km
6,8
9,4
12,3
15,9
15,7
58
113
201
357
335
SNCF CT 455
0,38
mm
Loop resistance:
20,1
52,5
/km
2500
2500
V/50Hz/3min
French Railways
(SNCF)
#
0,38
1-12
Dielectric strength:
conductor/conductor
a core: WH
b core: BK - BU - YE -BN - RD - GN
Sheath:
PVC, black
Marking
type - CT 455 - PENGG KABEL - month and year of production - <meter>
61
French Railways
PVC insulated, star-quad, with inductive protection
ZUT-S P
mutual capacity
#
1
Type
Construction
Conductor:
Insulation:
PVC
Colour code:
filling
cable elements
overall shield,
armouring
outer diameter
approx. mm
2
6
12
Application
The cable is designed for connection of railway network equipments in the
traffic control center.
number of
double cores
dimension of
conductor
number of
double cores
ZUT-S 2P1
ZUT-S 6P1
ZUT-S 12P1
2-12
8,2
14,0
18,0
weight
approx. kg/km
134
280
445
SNCF CT 455
mm
Loop resistance:
52,5
/km
2500
V/50Hz/3min
Dielectric strength:
conductor/conductor
a core: WH
b core: BK
c core: YE
d core: BU
Screening:
Sheath:
PVC, black
Marking
type - CT 455 - PENGG KABEL - month and year of production - <meter>
62
French Railways
PE insulated, star quads, with rodent protection
4D
0.8
mutual capacity
8-28
dimension of
conductor
number of
double cores
4D4
4D8
4 D 14
outer diameter
approx. mm
8
16
28
Application
The cable is designed for long distance telecommunications alongside railway
lines.
Construction
Conductor:
Insulation:
PE
Colour code:
a core: GY - OG
b core: WH - YE - BK - GN - BU - BN - RD
c core: VT
Conductor diameter:
0,8
Conductor resistance:
36,7
/km
Insulation resistance:
15
Gkm
nF/km
max: 54
nF/km
min:
46
nF/km
40
pF/300m
max
200
pF/300m
15
pF/300m
k1
k9-12
Sheath:
ea1/2
PE, black
Marking
<meter> - "SNCF" - type - "2329" - "ed0"- PENGG KABEL - year of production
mm
Capacitance unbalance:
Protective cover:
402
572
821
weight
approx. kg/km
17,0
19,9
23,6
d core: BU - BN - RD - WH - YE - BK - GN
Armouring:
filling
overall shield,
armouring
cable elements
Type
number of
double cores
French Railways
(SNCF)
C50
max
75
pF/300m
130
pF/300m
1600
pF/300m
conductor/conductor
1500
V/DC/1min
conductor/shield
3000
V/DC/1min
conductor/shield
3750
V/DC/3sek
max
Dielectric strength:
63
French Railways
Note
64
page 67
PE-ALT-CLT 1x4x1,53
page 68
Swiss Railways
(SBB)
PE4-ALT-CLT ...x4x...
65
Swiss Railways
Foam-skin PE insulated, star-quads, with rodent protection
C40
0,8
PE4-ALT-CLT ...x4x
mutual capacity
1,0
2-200
dimension of
conductor
filling
overall shield,
armouring
cable elements
Type
PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT
PE4-ALT-CLT
number of
double cores
1x4x..
3x4x..
5x4x..
10x4x..
20x4x..
30x4x..
50x4x..
outer diameter
approx. mm
outer diameter
approx. mm
2
6
10
20
40
60
100
Application
The cable is desigend for general use in railway telecommunication systems.
Construction
Conductor:
Insulation:
foam-skin PE (PE4)
Colour code :
a core: WH
b core: OG - GN - BN - GY
weight
approx. kg/km
14,6
18,5
21,8
23,0
28,8
31,1
37,4
200
340
440
635
974
1224
1790
Sheath:
Armouring:
Protective cover:
Marking
PENGG KABEL - year of procution - type - order number - "=>" (arrow from
the red end) - <meter>
66
541
923
1241
1872
2250
Conductor diameter:
0,8
1,0
mm
Loop resistance:
73,5
47,0
/km
Insulation resistance:
10
10
Gkm
Mutual capacitance:
40
40
nF/km
100%
380
380
pF/km
abs
65
65
pF/km
200
200
pF/km
35
35
pF/km
Capacitance unbalance:
k1
d core: VT
cores twisted to quads, quads stranded together in
concentric layer, wrapping with tape
20,8
26,3
30,8
36,7
53,5
weight
approx. kg/km
Standard:
c core: TQ
Cable make up:
number of
double cores
k9-12
abs
ea1/2
640
abs
100
640
100
pF/km
pF/km
Dielectric strength:
conductor/conductor
2000
V/50Hz/1min
conductor/shield
2000
V/50Hz/1min
-5 to +50
Temperatur range:
during installation
Swiss Railways
PE insulated, star-quads, with rodent protection
mutual capacity
1,5
2,2
2-60
dimension of
conductor
filling
overall shield,
armouring
cable elements
Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel
Sw-Kabel
number of
double cores
1x4x... CLT
3x4x... CLT
5x4x... CLT
10x4x... CLT
15x4x... CLT
20x4x... CLT
25x4x... CLT
30x4x... CLT
outer diameter
approx. mm
outer diameter
approx. mm
2
6
10
20
30
40
50
60
Application
The cable is designed for general use in protection systems with an operating
voltage 500 Veff (16 2/3 Hz) or 800 V DC.
Construction
Conductor:
Insulation:
PE
Colour code :
a core: WH
weight
approx. kg/km
15,5
23,5
28,5
36,0
41,0
46,5
52,5
55,0
223
558
785
1388
1946
2533
3150
3557
Conductor diameter:
1,5
2,2
mm
Loop resistance:
20,9
10,0
/km
Insulation resistance:
10
10
Gkm
Mutual capacitance:
52
60
nF/km
k1
400
400
pF/km
k9-12
400
400
pF/km
ea1/2
650
650
pF/km
Capacitance unbalance:
c core: TQ
Cable make up:
Sheath:
PE, black
Armouring:
Protective cover:
342
930
1380
2560
3630
4780
5850
6363
Standard:
b core: OR - GN - BN - GY
d core: VT
16,5
28,0
33,5
44,5
51,5
58,5
66,5
68,0
weight
approx. kg/km
Swiss Railways
(SBB)
Type
number of
double cores
Dielectric strength:
conductor/conductor
2000
V/50Hz/1min
conductor/shield
4000
V/50Hz/1min
Marking
SIGNAL - "=>" (arrow from the red end) - PENGG KABEL - year of production - order number - <meter>
67
Swiss Railways
PE insulated, star-quads, with inductive protection
PE-ALT-CLT 1x4x1,53mm
C42
1,53
Type
Construction
Conductor:
Insulation:
PE (PE)
a core: WH
cable elements
overall shield,
armouring
outer diameter
approx. mm
15,2
d core: VT
Cable make up:
Sheath:
Armouring:
Protective cover:
Marking
SIGNAL - PENGG KABEL - year of prodcution - type - order number - <meter>
weight
approx. kg/km
292
Conductor diameter:
1,53
mm
Loop resistance:
19,8
/km
Insulation resistance:
10
Gkm
max
48,6
nF/km
min
35,9
nF/km
0,8
dB/100m
120+/-5%
k1
240
pF/km
ea1/2
640
pF/km
conductor/conductor
2500
V/50Hz/1min
conductor/shield
2500
V/50Hz/1min
-5 to +50
Mutual capacitance:
b core: OR
c core: TQ
number of
double cores
filling
Application
The cable is designed for the connection of ETCS-Balisen.
dimension of
conductor
number of
double cores
PE-ALT-CLT 1x4x1,53
Colour code :
mutual capacity
Attenuation:
1,8 MHz
Impedance:
1,8 MHz
Capacitance unbalance:
Dielectric strength:
Temperature range:
during installation
68
page 71
Hungarian
Railways
(SBB)
69
mutual capacity
2-200
dimension of
conductor
0,8
number of
double cores
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
AJ-02YSF(L)2YD2Y
1x4x0,8 (HvrQ)
5x4x0,8 (HvrQ)
10x4x0,8 (HvrQ)
15x4x0,8 (HvrQ)
25x4x0,8 (HvrQ)
50x4x0,8 (HvrQ)
75x4x0,8 (HvrQ)
100x4x0,8 (HvrQ)
Construction
Conductor:
Insulation:
Colour code :
outer diameter
approx. mm
2
10
20
30
50
100
150
200
Application
The cable is designed for underground laying and drawing into conduits for
local networks.
a core: RD - GN - YE - BU - BN
15,0
21,0
27,0
29,0
36,0
45,0
54,0
61,0
Conductor diameter:
0,8
mm
Loop resistance:
73,2
/km
Insulation resistance:
Gkm
Mutual capacitance:
42
nF/km
100%
800
pF/300m
50%
400
pF/300m
300
pF/300m
400
pF/300m
800
pF/300m
conductor/conductor
500
V/50Hz/2min
conductor/shield
2000
V/50Hz/2min
during installation:
-5 to +70
during operation:
-30 to +70
Capacitance unbalance:
k1
k9-12 100%
d core: GY
Sheath:
Screening:
Protective cover:
350
690
1040
1210
1630
2510
3520
4420
c core: BK
cores twisted to quads, 5 quads cabled together to
basic strands, basic strands cabeld together in
concentric layer (50 quads);
weight
approx. kg/km
Standard:
b core: WT
filling
overall shield,
armouring
cable elements
Type
number of
double cores
50%
ea1/2 100%
Dielectric strength:
Temperature range:
Marking
MV ZRt. - handset symbol - <meter> - type - PENGG KABEL - year of procution - CE - order number
70
AJ-2Y(L)2YLB2Y x (BRQA)
mutual capacity
1,0
1,5
2-91
dimension of
conductor
filling
overall shield,
armouring
cable elements
number of
cores
AJ-2Y(L)2YLB2Y 2x...
AJ-2Y(L)2YLB2Y 4x...
AJ-2Y(L)2YLB2Y 7x...
AJ-2Y(L)2YLB2Y 10x...
AJ-2Y(L)2YLB2Y 14x...
AJ-2Y(L)2YLB2Y 21x...
AJ-2Y(L)2YLB2Y 30x...
AJ-2Y(L)2YLB2Y 37x...
AJ-2Y(L)2YLB2Y 48x...
AJ-2Y(L)2YLB2Y 61x...
AJ-2Y(L)2YLB2Y 75x...
AJ-2Y(L)2YLB2Y 91x...
2
4
7
10
14
21
30
37
48
61
75
91
Application
The cable is designed for connection of Station signal-safty equipments.
Cables can be burried directly into ground or can be laid in cable ducts, tubes
and indoor.
Construction
outer diameter
approx. mm
outer diameter
approx. mm
weight
approx. kg/km
12,0
15,5
16,8
18,7
19,5
21,5
24,5
25,6
27,8
29,4
31,6
33,3
250
362
432
515
590
821
1023
1129
1322
1507
1726
1944
14,2
17,1
18,6
21,1
22,1
25,6
28,3
29,8
32,7
35,2
38,1
40,2
weight
approx. kg/km
310
443
547
676
782
1170
1451
1645
1943
2338
2709
3099
Conductor diameter:
1,0
1,5
mm
Conductor resistance:
23,39
10,03
/km
Insulation resistance:
10
10
Gkm
Conductor:
Reduction factor:
Insulation:
PE (2Y)
Dielectric strength:
Colour code :
conductor/conductor
2000
V/50Hz/2min
conductor/screening
2000
V/50Hz/2min
cores are stranded in concentric layers; neighbouring layers must be stranded in opposite direction, wrapping with
tape
Sheath:
Screening:
Armouring:
Hungarian
Railways
(SBB)
Type
number of
cores
71
72
Slovenian Railways, SZ
page 74
Slovenian
Railways
(SZ)
SPZ ...x...
73
Slovenian Railways
PVC insulated, single core, with rodent protection
SPZ x
mutual capacity
0,9
1,4
2-133
dimension of
conductor
number of cores
filling
overall shield,
armouring
cable elements
Type
number of
cores
outer diameter
approx mm
weight
approx. kg/km
outer diameter
approx. mm
weight
approx. kg/km
SPZ 4 x ...
SPZ 5 x ...
SPZ 8 x ...
SPZ 10 x ...
SPZ 12 x ...
SPZ 16 x ...
SPZ 21 x ...
SPZ 24 x ...
SPZ 27 x ...
SPZ 33 x ...
SPZ 40 x ...
SPZ 48 x ...
SPZ 61 x ...
SPZ 80 x ...
SPZ 108 x ...
SPZ 133 x ...
4
5
8
10
12
16
21
24
27
33
40
48
61
80
108
133
12,0
12,2
13,1
14,6
14,9
16,0
16,8
18,4
19,5
19,8
22,1
23,7
25,3
28,0
31,7
35,1
210
218
256
326
350
408
471
530
611
639
794
898
1054
1282
1636
2028
13,9
14,6
15,9
17,4
17,8
20,1
20,4
24,2
24,6
26,0
27,0
30,2
32,4
35,7
41,8
45,6
294
322
402
488
535
691
771
965
1032
1180
1263
1592
1896
2305
3116
3799
Application
Standard:
Conductor diameter:
0,9
1,4
mm
Conductor resistance:
28,9
11,9
/km
Insulation resistance:
km
Mutual capacitance:
180
210
nF/km
2000
V/50Hz/1min
Construction
Conductor:
Insulation:
PVC (P)
Colour code :
red
blue
grey
Sheath:
PVC, black
Armouring:
Protective cover:
PVC, black
Temperature range:
during installation
-5 to +70
during operation
up to +60
Marking
<meter> - type- JZS S2.011 - PENGG KABEL
74
A-DF(ZN)2Y4Y
page 78
A-DF(ZN)2Y(SR)2Y
page 80
page 82
page 84
page 86
page 88
page 89
page 90
page 91
page 92
page 93
page 94
page 95
page 96
Fiber Optic
Cables
A-DF(ZN)2Y
75
76
A-DF(ZN)2Y
Typ
number of tubes
+ fillers
number of
fibers / tube
numbers of
fibers
tube-diameter
approx. mm
tensile strength
max. N
weight
approx. kg/km
outer diameter
approx. mm
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
1+5
2+4
3+3
4+2
5+1
6+0
2 (4)
2 (4)
2 (4)
2 (4)
2 (4)
2 (4)
2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)
2,0
2,0
2,0
2,0
2,0
2,0
1500
1500
1500
1500
1500
1500
75
75
75
75
75
75
9,5
9,5
9,5
9,5
9,5
9,5
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
1+4
2+3
3+2
4+1
5+0
6+0
6
6
6
6
6
6
6
12
18
24
30
36
2,8
2,8
2,8
2,8
2,8
2,8
1500
1500
1500
1500
1500
1500
95
95
95
95
95
120
11,0
11,0
11,0
11,0
11,0
12,0
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
1+4
2+3
3+2
4+1
5+0
6+0
8
8
8
8
8
8
8
16
24
32
40
48
2,8
2,8
2,8
2,8
2,8
2,8
1500
1500
1500
1500
1500
1500
95
95
95
95
95
120
11,0
11,0
11,0
11,0
11,0
12,0
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0
12
12
12
12
12
12
12
12
12
12
12
12
24
36
48
60
72
96
120
144
192
216
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
1500
1500
1500
1500
1500
1500
2000
2000
3000
3000
3000
95
95
95
95
95
120
145
185
235
215
245
11,0
11,0
11,0
11,0
11,0
12,0
13,7
15,5
17,3
16,7
17,7
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0
24
24
24
24
24
24
24
24
96
120
144
192
240
288
384
432
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
1500
1500
1500
2000
2000
3000
3000
3000
95
95
125
150
195
245
230
260
11,0
11,0
12,0
13,7
15,5
17,3
16,7
17,7
Typ
number of tubes
+ fillers
number of
fibers / tube
numbers of
fibers
tube-diameter
approx. mm
tensile strength
max. N
weight
approx. kg/km
outer diameter
approx. mm
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
6
6
6
6
6
6
6
12
18
24
30
36
2,3
2,3
2,3
2,3
2,3
2,3
1500
1500
1500
1500
1500
1500
80
80
80
80
80
95
10,0
10,0
10,0
10,0
10,0
10,5
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
8
8
8
8
8
8
8
16
24
32
40
48
2,3
2,3
2,3
2,3
2,3
2,3
1500
1500
1500
1500
1500
1500
80
80
80
80
80
95
10,0
10,0
10,0
10,0
10,0
10,5
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
A-DF(ZN)2Y
1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0
12
12
12
12
12
12
12
12
12
12
12
12
24
36
48
60
72
96
120
144
192
216
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
1500
1500
1500
1500
1500
1500
2000
2000
3000
3000
3000
89
89
89
89
89
95
115
145
185
165
185
10,0
10,0
10,0
10,0
10,0
10,5
12,0
13,3
15,0
14,5
15,0
Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
jelly filled cable core
strength members (aramide yarns)
PE-sheath, UV-resistant, black
Technical Data
tensile strength
compressive strength
(crush)
Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink
impact
Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)
torsion
Note
longitudinally water-tight
kink, cable
On request
other number of tubes
increased tensile strength
reinforced outer sheath (2YV)
other sheath colours
coloured stripes
HDPE or LDPE sheath
other tube and fiber colours
Laying
usable for fixed laying in earth, ducts or conduits and outdoors
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request
temperature range
water penetration
Fiber Optic
Cables
Application
For telecommunication and information systems.
77
78
A-DF(ZN)2Y4Y
Typ
number of tubes
+ fillers
number of
fibers / tube
numbers of
fibers
tube-diameter
approx. mm
tensile strength
max. N
weight
approx. kg/km
outer diameter
approx. mm
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
1
2
3
4
5
6
+
+
+
+
+
+
5
4
3
2
1
0
2
2
2
2
2
2
2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)
2,0
2,0
2,0
2,0
2,0
2,0
1500
1500
1500
1500
1500
1500
90
90
90
90
90
90
10,5
10,5
10,5
10,5
10,5
10,5
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
6
6
6
6
6
6
6
12
18
24
30
36
2,8
2,8
2,8
2,8
2,8
2,8
1500
1500
1500
1500
1500
1500
115
115
115
115
115
134
12,0
12,0
12,0
12,0
12,0
13,0
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
8
8
8
8
8
8
8
16
24
32
40
48
2,8
2,8
2,8
2,8
2,8
2,8
1500
1500
1500
1500
1500
1500
115
115
115
115
115
135
12,0
12,0
12,0
12,0
12,0
13,0
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0
12
12
12
12
12
12
12
12
12
12
12
12
24
36
48
60
72
96
120
144
192
216
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
1500
1500
1500
1500
1500
1500
2000
2000
3000
3000
3000
115
115
115
115
115
136
170
210
265
240
275
12,0
12,0
12,0
12,0
12,0
13,0
14,7
16,5
18,3
17,7
18,7
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0
24
24
24
24
24
24
24
24
96
120
144
192
240
288
384
432
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
1500
1500
1500
2000
2000
3000
3000
3000
120
120
145
175
220
275
255
290
12,0
12,0
13,0
14,7
16,5
18,3
17,7
18,7
(4)
(4)
(4)
(4)
(4)
(4)
Typ
number of tubes
+ fillers
number of
fibers / tube
numbers of
fibers
tube-diameter
approx. mm
tensile strength
max. N
weight
approx. kg/km
outer diameter
approx. mm
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
1+4
2+3
3+2
4+1
5+0
6+0
6
6
6
6
6
6
6
12
18
24
30
36
2,3
2,3
2,3
2,3
2,3
2,3
1500
1500
1500
1500
1500
1500
95
95
95
95
95
110
11,0
11,0
11,0
11,0
11,0
11,5
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
1+4
2+3
3+2
4+1
5+0
6+0
8
8
8
8
8
8
8
16
24
32
40
48
2,3
2,3
2,3
2,3
2,3
2,3
1500
1500
1500
1500
1500
1500
95
95
95
95
95
110
11,0
11,0
11,0
11,0
11,0
11,5
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y4Y
1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
16 + 0
18 + 0
12
12
12
12
12
12
12
12
12
12
12
12
24
36
48
60
72
96
120
144
192
216
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
1500
1500
1500
1500
1500
1500
2000
2000
3000
3000
3000
95
95
95
95
95
110
135
165
210
190
210
11,0
11,0
11,0
11,0
11,0
11,5
13,0
14,4
16,0
15,5
16,0
Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
filling of cable core
strength members (aramide yarns)
PE-sheath, UV-resistant, black
PA-protective cover, UV-resistant, transparent
Technical Data
tensile strength
compressive strength
(crush)
Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink
impact
Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)
torsion
Note
longitudinally water-tight
kink, cable
On request
other number of tubes
increased tensile strength
other sheath colours
coloured stripes
HDPE or LDPE sheath
other tube and fiber colours
Laying
usable for fixed laying in earth, ducts or conduits and outdoors
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request
temperature range
water penetration
Fiber Optic
Cables
Application
For telecommunication and information systems.
79
80
A-DF(ZN)2Y(SR)2Y
Typ
numbers of
fibers
tube-diameter
approx. mm
tensile strength
max. N
weight
approx. kg/km
outer diameter
approx. mm
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
1+5
2+4
3+3
4+2
5+1
6+0
2 (4)
2 (4)
2 (4)
2 (4)
2 (4)
2 (4)
2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)
2,0
2,0
2,0
2,0
2,0
2,0
2000
2000
2000
2000
2000
2000
180
180
180
180
180
180
14,0
14,0
14,0
14,0
14,0
14,0
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
1+4
2+3
3+2
4+1
5+0
6+0
6
6
6
6
6
6
6
12
18
24
30
36
2,8
2,8
2,8
2,8
2,8
2,8
2500
2500
2500
2500
2500
3000
220
220
220
220
220
250
15,5
15,5
15,5
15,5
15,5
16,5
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
1+4
2+3
3+2
4+1
5+0
6+0
8
8
8
8
8
8
8
16
24
32
40
48
2,8
2,8
2,8
2,8
2,8
2,8
2500
2500
2500
2500
2500
3000
220
220
220
220
220
250
15,5
15,5
15,5
15,5
15,5
16,5
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
12
12
12
12
12
12
12
12
12
12
24
36
48
60
72
96
120
144
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2500
2500
2500
2500
2500
3000
3500
4000
4500
220
220
220
220
220
250
290
345
410
15,5
15,5
15,5
15,5
15,5
16,5
18,0
20,0
21,7
Typ
numbers of
fibers
tube-diameter
approx. mm
tensile strength
max. N
weight
approx. kg/km
outer diameter
approx. mm
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
6
6
6
6
6
6
6
12
18
24
30
36
2,3
2,3
2,3
2,3
2,3
2,3
2500
2500
2500
2500
2500
3000
195
195
195
195
195
215
14,2
14,2
14,2
14,2
14,2
15,0
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
8
8
8
8
8
8
8
16
24
32
40
48
2,3
2,3
2,3
2,3
2,3
2,3
2500
2500
2500
2500
2500
3000
195
195
195
195
195
215
14,2
14,2
14,2
14,2
14,2
15,0
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
A-DF(ZN)2Y(SR)2Y
1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
12
12
12
12
12
12
12
12
12
12
24
36
48
60
72
96
120
144
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2,3
2500
2500
2500
2500
2500
3000
3500
4000
4500
195
195
195
195
195
215
245
290
345
14,2
14,2
14,2
14,2
14,2
15,0
16,2
17,7
19,5
Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
jelly filled cable core
strength members (aramide yarns)
PE-inner sheath
corrugated steel tape, laminated
PE-outer sheath, UV-resistant, black
Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink
Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)
Technical Data
tensile strength
compressive strength
(crush)
impact
torsion
kink, cable
Note
longitudinally water-tight
On request
other number of fibers (max. 432)
other number of tubes
increased tensile strength
reinforced outer sheath (2YV)
other sheath colours
coloured stripes
HDPE or LDPE sheath
other tube and fiber colours
dry filled version
Laying
usable for fixed laying in earth, ducts or conduits and outdoors
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request
temperature range
water penetration
Fiber Optic
Cables
Application
For telecommunication and information systems.
81
82
Typ
number of tubes
+ fillers
number of
fibers / tube
numbers of
fibers
tube-diameter
approx. mm
tensile strength
max. N
weight
approx. kg/km
outer diameter
approx. mm
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
1
2
3
4
5
6
+
+
+
+
+
+
5
4
3
2
1
0
2
2
2
2
2
2
2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)
2,3
2,3
2,3
2,3
2,3
2,3
6.000
6.000
6.000
6.000
6.000
6.000
140
140
140
140
140
140
13,0
13,0
13,0
13,0
13,0
13,0
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
6
6
6
6
6
6
6
12
18
24
30
36
2,8
2,8
2,8
2,8
2,8
2,8
6.000
6.000
6.000
6.000
6.000
6.000
145
145
145
145
145
170
13,6
13,6
13,6
13,6
13,6
14,6
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
8
8
8
8
8
8
8
16
24
32
40
48
2,8
2,8
2,8
2,8
2,8
2,8
6.000
6.000
6.000
6.000
6.000
6.000
145
145
145
145
145
170
13,6
13,6
13,6
13,6
13,6
14,6
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
A-DQ(ZN)2Y
1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
12
12
12
12
12
12
12
12
12
12
24
36
48
60
72
96
120
144
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
6.000
6.000
6.000
6.000
6.000
6.000
6.000
6.000
6.000
145
145
145
145
145
170
200
245
300
13,6
13,6
13,6
13,6
13,6
14,6
16,2
18,0
19,8
(4)
(4)
(4)
(4)
(4)
(4)
Application
Metal-free aerial cable (ADSS = alldielectric selfsupporting) for telecommunication and information systems.
Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
strength members (aramide yarns)
HDPE-outer sheath, UV-resistant, black
Technical Data
tensile strength
compressive strength
(crush)
impact
Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink
torsion
Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)
kink, cable
Note
not longitudinally water-tight
On request
other number of tubes
for temperatures down to -60C
other tube and fiber colours
Laying
usable for fixed laying on selfsupporting lines (up to 60kV) and
overhead contact lines, in earth, ducts or conduits and outdoors
temperature range
water penetration
span distance
Fiber Optic
Cables
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request
83
Typ
84
number of tubes
+ fillers
number of
fibers / tube
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
1
2
3
4
5
6
+
+
+
+
+
+
5
4
3
2
1
0
2
2
2
2
2
2
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
1
2
3
4
5
6
+
+
+
+
+
+
4
3
2
1
0
0
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
A-D2Y(ZN)2Y
1+4
2+3
3+2
4+1
5+0
6+0
8+0
10 + 0
12 + 0
(4)
(4)
(4)
(4)
(4)
(4)
numbers of
fibers
tube-diameter
approx. mm
tensile strength
max. N
weight
approx. kg/km
outer diameter
approx. mm
2 (4)
4 (8)
6 (12)
8 (16)
10 (20)
12 (24)
2,3
2,3
2,3
2,3
2,3
2,3
6.000
6.000
6.000
6.000
6.000
6.000
135
135
135
135
135
135
13,0
13,0
13,0
13,0
13,0
13,0
6
6
6
6
6
6
6
12
18
24
30
36
2,8
2,8
2,8
2,8
2,8
2,8
6.000
6.000
6.000
6.000
6.000
6.000
140
140
140
140
140
165
14,1
14,1
14,1
14,1
14,1
14,6
8
8
8
8
8
8
8
16
24
32
40
48
2,8
2,8
2,8
2,8
2,8
2,8
6.000
6.000
6.000
6.000
6.000
6.000
140
140
140
140
140
165
14,1
14,1
14,1
14,1
14,1
14,6
12
12
12
12
12
12
12
12
12
12
24
36
48
60
72
96
120
144
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
2,8
6.000
6.000
6.000
6.000
6.000
6.000
6.000
6.000
6.000
140
140
140
140
140
162
196
246
295
14,1
14,1
14,1
14,1
14,1
14,6
16,2
18,1
20,0
Application
Metal-free aerial cable (ADSS = alldielectric selfsupporting) for telecommunication and information systems.
Construction
FRP-central element
loose tubes, SZ-cabling (if necessary with fillers)
dry filled cable core
strength members (aramide yarns)
HDPE-outer sheath, UV-resistant, black
Technical Data
tensile strength
compressive strength
(crush)
impact
Fiber colours
red, green, blue, yellow, white, grey, brown, violet, turquoise, black,
orange, pink
torsion
Tube colours
counter core red,
others yellow (E9), green (G50) or blue (G62,5)
kink, cable
Note
not longitudinally water-tight
Laying
usable for fixed laying on selfsupporting lines (up to 60kV) and
overhead contact lines, in earth, ducts or conduits and outdoors
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request
temperature range
water penetration
span distance
Fiber Optic
Cables
On request
other number of tubes
for temperatures down to -60C
other tube and fiber colours
85
Type
A-DQ(ZN)2Y (HD)
number
of fibers
number of tubes
(fillers)
tube-
approx. mm
tensile strength
max. N
outer-diameter
approx. mm
weight
approx. kg/km
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
1x4
1x8
1x12
2x12
3x12
4x12
5x12
6x12
8x12
12x12
4
8
12
24
36
48
60
72
96
144
1 (5)
1 (5)
1 (5)
2 (4)
3 (3)
4 (2)
5 (1)
6 (0)
8 (0)
12 (0)
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
700
700
700
700
700
700
700
700
700
700
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
6.5
8.5
30
30
30
30
30
30
30
30
43
63
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
A-DQ(ZN)2Y (HD)
1x4
1x8
1x12
2x12
3x12
4x12
5x12
6x12
8x12
12x12
4
8
12
24
36
48
60
72
96
144
1 (5)
1 (5)
1 (5)
2 (4)
3 (3)
4 (2)
5 (1)
6 (0)
8 (0)
12 (0)
1,7
1,7
1,7
1,7
1,7
1,7
1,7
1,7
1,7
1,7
900
900
900
900
900
900
900
900
900
900
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
7.4
10.5
37
37
37
37
37
37
37
37
56
88
A-DQ(ZN)2Y (HD)
6x24
144
6 (0)
2,0
900
8.0
71
Application
Suitable for Metro, Access or FTTx implementations
Technical Data
Construction
rip cord
central member, metal free
loose buffer tube filled with a thixotropic gel, swellable aramid yarns
dry filled cable core
HDPE-sheath, UV-resistant, black
Temp. range
Crush resistance
900 N/10 cm
Impact strength
Water penetration
Bending radius
1 m (0.1 bar, 24 h)
permanent
during installation
Fiber colours
blue, orange, green, brown, slate, white, red, black, yellow, violet,
pink, turquoise
-30C up to +60C
-5C up to +50C
-30C up to +60C
65 mm
90 mm
Tube colours
up to 12 tubes: blue, orange, green, brown, slate, white, red, black,
yellow, violet, pink, turquoise
Filling element colour
natural
On request
other sheath colours
other tube and fiber colours
Laying
for installation in miniduct systems
Marking
double-sinus, phone-sign, meter marking, PENGG KABEL, year of
manufacturing
other markings on request
86
Fiber Optic
Cables
Note
87
E9
Mechanical Properties
core diameter d
core concentricity error
cladding diameter
cladding non-circularity
cladding/coating concentricity error
coating non-circularity
fiber diameter
at 1310 nm
at 1550 nm
uncoloured
coloured
at 1310
at 1383
at 1490
at 1550
at 1625
at 1310
at 1310
at 1310
at 1550
at 1285
at 1260
at 1480
nm
nm
nm
nm
nm
and 1550 nm
and 1550 nm
and 1550 nm
20 nm
1330 nm
1360 nm
1580 nm
88
m
m
m
m
%
m
%
m
m
N
kpsi
N
mm
max / typical
0.34 / 0.32
0.31 / 0.28
0.23 / 0.21
0.21 / 0.19
0.23 / 0.20
0.05
0.05
0.05
0.22
3
12
19
0.1
0.06
11501330
dB/km
dB/km
dB/km
dB/km
dB/km
dB/km
dB
dB/km
dB/km
ps/(nm*km)
ps/(nm*km)
ps/(nm*km)
ps/km
ps/km
nm
1260
nm
0.05
1300 1322
dB
nm
s0
0.092
ps/(nm*km)
refraction index
at 1310 nm
at 1550 nm
1.467
1.468
cff-range
9.2 0.4
10.4 0.5
0.5
125 0.7
0.7
12.0
6.0
242 5
250 10
8
120
3.5
30
Mechanical Properties
core diameter d
coreconcentricity error
cladding diameter
cladding non-circularity
cladding/coating concentricity error
coating non-circularity
fiber diameter
at 1310 nm
at 1550 nm
uncoloured
coloured
refraction index
attenuation inequality (.......)
attenuation alteration (range -60 up to +85C)
chromatic dispersion
polarization mode dipersion (PMD)
fiber cut-off wavelength (referred to RTM)
at 1310 nm
at 1383 nm
at 1490 nm
at 1550 nm
at 1625 nm
at 1310 nm
at 1550 nm
at 1310 and 1550 nm
at 1310 und 1550 nm
at 1288 1339 nm
at 1550 nm
cf-range
A2/B2
8.5 - 9.3
9.5 - 10.5
0.5
125 0.7
1.0
12.0
6.0
235 - 245
max. 265
8
100
3.5
10
max. / typical
0.35 / 0.34
0.31 / 0.28
0.24 / 0.21
0.21 / 0.19
0.24 / 0.20
1.467
1.468
0.05
0.05
3.5
18
0.2
11501330
max. / typical
0.35 / 0.34
0.31 / 0.28
0.24 / 0.21
0.21 / 0.19
0.24 / 0.20
1.467
1.468
0.05
0.05
3.5
18
0.2
11501330
m
m
m
m
%
m
%
m
m
N
kpsi
N
mm
dB/km
dB/km
dB/km
dB/km
dB/km
dB/km
dB/km
ps/(nm*km)
ps/(nm*km)
ps/km
nm
1260
1260
nm
0.05
1302 1322
0.05
1300 1324
dB
nm
s0
0.092
0.092
ps/(nm*km)
at 1550 nm
at 1625 nm
at 1550 nm
at 1625 nm
at 1550 nm
at 1625 nm
at 1550 nm
at 1625 nm
0.01
0.05
0.2
0.5
0.2
0.5
-
0.03
0.1
0.1
0.2
0.5
1.0
dB
dB
dB
dB
dB
dB
dB
dB
Macrobend Performances
100 turns on a 25mm radius mandrel
10 turns on a 15mm radius mandrel
1 turns on a 10mm radius mandrel
1 turns on a 7.5mm radius mandrel
cff-range
A1
8.5 - 9.3
9.5 - 10.5
0.5
125 0.7
1.0
12.0
6.0
235 - 245
max. 265
8
100
3.5
10
Fiber Optic
Cables
Common
fiber type
standard
fiber describtion
E9
89
E8
Mechanical Characteristics
G.656
(G.655.c, e)
True-Wave
Reach
8.6 0.4
125 0.7
0.5
0.7
12.0
6.0
242 5
265
8
G.655.d
(G.655.c)
True-Wave
RS
8.4 0.6
8.7 0.6
125 0.7
0.5
0.7
12.0
6.0
242 5
265
8
Tera Light
MetroFiber
9.2 0.5
125 1
0.6
1.0
12.0
5.0
242 7
265
8
Tera Light
UltraFiber
9.2 0,5
125 1
0.6
1.0
12.0
6.0
242 7
265
8
9.6 0.4
125 0.7
0.5
0.7
12.0
6.0
245 5
265
8
m
m
m
m
%
m
%
m
m
N
100
3.5
30
100
3.5
30
100
3
30
100
3.5
30
100
3
30
kpsi
N
mm
at 1550 nm
at 1625 nm
at 1383 3 nm
0.22
0.24
0.4
0.22
0.24
0.4
0.25
0.28
1.0
0.22
0.25
0.7
0.22
0.24
0.4
dB/km
dB/km
dB/km
at 1550 nm
at 1625 nm
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
dB
dB
at 1550 nm
at 1625 nm
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
dB
dB
dB/km
at 1550 nm
at 1530 1565 nm
at 1565 1620 nm
link design value
max. individual fiber
at 1550 nm
at 1550 nm
0.05
5.5-8.9
6.9-11.4
0.04
0.1
0.05
1.470
0.05
2.6-6.0
4.0-8.9
0.04
0.1
0.05
1.470
0.05
5.5-10.0
7.5-13.8
0.08
0.2
0.1
1.469
0.1
5.5-10.0
7.5-13.4
0.04
0.05
1.469
0.05
2.6-6.0
4.5-11.2
0.04
0.1
0.05
1.468
dB
ps/(nm*km)
ps/(nm*km)
ps/km
ps/km
dB
core diameter d
cladding diameter
core/cladding excentricity
cladding non-circularity
cladding/coating excentricity
coating non-circularity
fiber diameter
at 1550 nm
at 1600 nm
uncoloured
coloured
1)
90
G.656
(G.655.e)
G.656
(G.655.e)
TM
G.655.d
TM
Leaf
at TeraLight Fibers: 60 mm
TM
Compostion
core
cladding
coating
Geometrical Characteristics
core diameter d
cladding diameter
core/cladding concentricity error
cladding non-circularity
fiber curl radius
primary coating diameter
coating/cladding concentricity error
Optical Characteristics
attenuation
point discontinuity
chromatic dispersion
at 1550 nm
at
at
at
at
at
at
at
1460
1550
1625
1550
1460
1530
1565
nm (only G.656)
nm
nm
nm
to 1625 nm (only G.656)
to 1565 nm
to 1625 nm
G.656
(G.655.c, e)
9.0 0.5
125.0 1.0
0.7
4
242 5
12
G.655.a
(G.655.d)
9.6 0.4
125.0 0.7
0.5
0.7
4
245 5
12
m
m
0.5
%
m
m
m
0.26
0.22
0.25
0.10
2.0 bis 13.5
5.5 bis 10.0
7.5 bis 13.5
1450
0.22
0.25
0.05
2.0 bis 6.0
4.5 bis 11.2
1450
dB/km
dB/km
dB/km
dB
ps/(nm*km)
ps/(nm*km)
ps/(nm*km)
nm
0.10
-
0.10
0.04
ps/km
ps/km
120
120
0.05
0.5
1.3 bis 8.9
20
0.05
0.5
1.3 bis 8.9
20
dB
dB
N
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
dB/km
dB/km
dB/km
dB/km
Fiber Optic
Cables
Common
fiber type
standard
fiber describition
E8
91
G50
Mechanical Properties
core diameter d
core non-circularity
core/cladding concentricity error
cladding diameter
cladding non-circularity
cladding/coating concentricity error
coating non-circularity
fiber diameter
uncoloured
coloured
band width
attenuation (makrobending)
attenuation alteration (range -60 up to +85C)
numeric aperture
refraction index
link lengths at 1 Gb/s
92
at
at
at
at
at
850nm
1300 nm
1383 nm
850 nm
1300 nm
at
at
at
at
at
850 nm
850 nm
1300 nm
850 nm
1300 nm
50 2.5
5.0
1.5
125 2
1.0
10.0
6.0
245 10
265
8
100
3.5
30
m
%
m
m
%
m
%
m
m
N
kpsi
N
mm
2.5
0.6
2.0
400 - 750
500 - 1200
0.5
0.2
0.2 0.015
1.4825
1.4775
500 - 750
550 - 2000
dB/km
dB/km
dB/km
MHz*km
MHz*km
dB
dB/km
(others on request)
(others on request)
m
m
G50
Mechanical Properties
core diameter d
core non-circularity
core/cladding concentricity error
cladding diameter
cladding non-circularity
cladding/coating concentricity error
coating non-circularity
fiber diameter
uncoloured
coloured
refraction index
attenuation (makrobending)
attenuation alteration (range -60 up to +85C)
numeric aperture
at
at
at
at
at
850nm
1300 nm
1383 nm
850 nm
1300 nm
at 850 nm
50 2.5
5.0
1.5
125 1
1.0
10.0
6.0
245 10
265
8
100
3.5
30
m
%
m
m
%
m
%
m
m
N
kpsi
N
mm
2.5
0.7
2.0
1.4825
1.4775
0.5
0.2
0.2 0.015
dB/km
dB/km
dB/km
dB
dB/km
Performance Characteristics
Upon request our fiber can be selected meeting inner mask radial specifications more stringent than the TIA/EIA-492 AAAC requirement:
Inner mask: Rinner = 0 m to Router = 18 m
Further to meeting the respective DMD template all OptiGrade fiber meets the additional requirement of IEC 60793-2-10 in the radial offset
intervall masks, which sources out fibers, having rapid changes of the DMD.
Transmission link lenghts
850 nm
300
400
500
550
m
for 10 Gb/s*
1300 nm (LX4)
300
300
300
300
m
*at 850 nm operating
radius 4.5 m
30 %
wavelenth with transmitters
radius 19.0 m
86 %
meeting encircled flux at
Fiber Optic
Cables
OptiGrade Classes
300
400
500
550
Bandwith
850 nm
1500
2000
2500
3500
MHz*km
(Overfilled Launch, LED based sources) 1300 nm
500
500
500
500
MHz*km
Effective Modal Bandwith
850 nm
2000
2700
4000
4700
MHz*km
Assured by: Differential Mode Delay (DMD)
Fibers shall meet the respective DMD templates specified in or according to the standard TIA/EIA or IEC 60793-2-10, for transmitters meeting TIA/EIA-492 AAAC. Each template includes an inner and an outer mask requirement with:
Inner mask:
Outer mask:
Rinner = 5 m to Router = 18 m
Rinner = 0 m to Router = 23 m
93
G62,5
Mechanical Properties
core diameter d
core non-circularity
cladding diameter
core/cladding concentricity error
cladding non-circularity
cladding/coating excentricity
coating non-circularity
fiber diameter
uncoloured
coloured
band width
attenuation (makrobending)
attenuation alteration (range -60 up to +85C)
numeric aperture
refraction index
link lengths at 1 Gb/s
94
at
at
at
at
at
850nm
1300 nm
1383 nm
850 nm
1300 nm
at
at
at
at
at
850 nm
850 nm
1300 nm
850 nm
1300 nm
62.5 2.5
5.0
125 2
1.5
1.0
10.0
6.0
245 10
265
8
100
3.5
30
m
%
m
m
%
m
%
m
m
N
kpsi
N
mm
3.0
1.0
2.0
160 - 250
500 - 800
0.05
0.2
0.275 0.015
1.4965
1.4920
300 - 500
550 - 1000
dB/km
dB/km
dB/km
MHz*km
MHz*km
dB
dB/km
dB
(Standard 200)
(Standard 600)
m
m
Fiber Optic
Cables
95
Ring Signing:
1xn
2xn
3xn
4xn
5xn
1xn
2xn
3xn
4xn
5xn
Singlemode Fibers
NZDF-Fibers E8
Multimode Fibers G50
no fiber assignment
6-tubes construction
6x n
Singlemode Fibers E9
NZDF-Fibers E8
Multimode Fibers G50
no fiber assignment
96
General Information
Types
page 98
Letter symbols
page 99
page 99
page 100
Units
page 100
page 100
Shifting guideline
page 102
Bending radius
page 102
Installation temperature
page 102
page 102
Tensile load for telecommunication cables with guaranteeing tensile strength resistance page 103
Common explanations
page 104
page 104
page 105
page 105
RAL-colour code
page 106
page 107
page 109
page 109
page 110
page 113
General
Information
Terms of delivery
97
Types
Signalling- and measuring cables
Switchboard cables
Signal and measuring cables are used for transmission of DC- and low Switchboard cables are used as connection between racks, main disfrequency AC-signals in telemetering-, signal-, clock- and paging tributors and switch stations in different kinds of railway offices (censystems as well as for control system (railway signals, signal boxes) tral offices, amplification bases and signal boxes).
and for supervision systems.
The cores are PVC-insulated. Cores are stranded together in layers;
The cables consist of PE-insulated cores, which are stranded together shielded pairs, triples, quads or quintuples are stranded together in
in concentric layers. The non-armoured types have a PVC-sheath over layers or units. The shielded types have a screening of aluminium lamithe cable core, the armoured types have a PVC-sheath (PE-sheath nated PET-foil (static shield) over the cable core, the switchboard
according to VE), a steel tape armouring and a PVC-outer protective cables have a PVC-sheath.
cover.
They are used in local telecom networks, for the connection of tele- They are used for switching and wiring of telecommunication instruphone sets to telephone exchanges and as connection cables in indu- ments and similar ones, i.e. telephone exchanges, amplification bases
strial fields and in offices.
and selection amplifiers.
The cables have quads of PE-, foam-PE- or foam-skin-PE They consist of one or more twisted cores with PVC-insulation.
insulated cores; the quads are stranded to unitss, the units are stranded to the cable core. The composite-layer sheath have a double-coated aluminium foil bonded with the PE-sheath. Petrol jelly fillings or
swellable materials prevents water penetration along the cable.
Shielded switchboard strands
For special applications or customer-specifications the cables get They are used for switching of telecommunication instruments and
additionally components, for example:
similar ones, e.g. telephone exchanges, amplification bases and selection amplifiers.
PE-sheath, reinforced
steel tape or steel wire armouring
Shielded switchboard strands consists of one or more twisted, PVC PE or PVC protective cover
insulated cores, a copper braid screening and a PVC-sheath.
aluminium laminated PET-foil instead of aluminium
tape
Selfsupporting aerial carrier cables, so called SETRA cables, are used Telecommunication installation wires are used for switching of telewithin the telecommunication network of the PTTs as well as in the com instruments in dry and eventually dump areas.
domain of private telecom and data transmission networks.
They consists of one or more twisted PVC-insulated cores.
They have PE-insulated quads cabled to units and if necessary a
shielding of aluminium foil; cable core and a supporting rope of galvanized steel wires with common PE-sheath (e.g. PVC-sheath). Also
available with quads stranded in layers.
Installation cables
They are mainly needed for construction of telephone sets and exten- Telecom cables for very specified applications and different special
sions and suited for fixed laying on dry and wet ground material indo- constructions (i.e. power protection cables, lightning protected teleor and outdoor.
communication cables,railway signalling cables with inductive protection,...) belong to this field.
The PVC-insulated pairs or quads are stranded together in layers or
units. Depending on the type the cables are unshielded or shielded
with an aluminium foil (static shield) and surrounded with a PVCsheath.
Control cables
These cables are used for transmission of signals and measuring Control cables are used for transmission of analogue and digital sigvalues in units of the measuring, control and power electronic techni- nals. Special constructions have proven to work under difficult transques as well as for data processing.
fer conditions and extreme severe environmental influences.
They are composed of PVC-insulated cores or pairs stranded Main applications: industrial process control, refineries, fuel dumps,
together into units. The shielded types have a screening of aluminium chemical industry, power plants, as well as in sciences and research
foil or copper braid. The cables for industrial electronics have a PVC- work.
sheath.
98
Description
Letter
symbol
Description
AA
AB
AD-
LG
LI
M
MZ
2M
(M...)
OF
P
P
PAP
PE
perf
Q
(R...)
R
S
SSSMPE
SPE
ST
AJAL
AL+PE
B
BD
(1B...)
C
C
C
CU
D
DM
E
F
F
F
F
FFIFOL
(FA)
(F...)
G
GH
(H...)
J
JJE...IMF
-K
(K)
Kx
KF
L
(L)
(L)2Y
LLD
ST I
ST III
(S...)
(ST)
T
TF
TF
V
VAS
vzn
W
Y
YV
Y3V
(Z)
(ZG)
2Y
2YV
2Y3V
02Y
02YH
02YS
Installation cablel with 20 PVC-insulated pairs, bare copper conductor, diameter 0,6 mm, stranded in layers, plastic tape wrapping, static
shield PETP aluminium foil with drain wire and PVC-sheath; (according to VDE 0815).
A-2YYBY 16x1x0.9 S LG
Railway signal cable with 16 PE insulated cores, stranded in layers, bare copper conductor, diameter 0.9 mm, plastic tape wrapping, PVCsheath, stell tape armouring and PVC protective cover (according to VDE 0816/part 2).
Railway Cables 07/2013 by PENGG KABEL GmbH Subject to technical alterations
General
Information
J-Y(ST)Y 20x2x0.6 LG
99
Symbol
Letter symbol
angular frequency
attenuation (equivalent)
attenuation coefficient
capacitance load per unit length
capacitance unbalance
conductivity
conductance
conductance per unit length
conductor cross section
conductor resistance
current, strength of current
dissipation factor
frequency
group delay
inductivity
inductivity load per unit length
insulation resistance
image phase change coefficient
impedance (amount)
impedance (complex)
impedance (imaginary part)
impedance (real part)
line length
level
magnetic unbalance
mutual capacitance
mutual inductance
near end cross talk attenuation (equivalent)
phase delay
power
reduction factor
reflection coefficient
relative permittivity
resistance load per unit length
specific resistance
temperature
velocity of propagation
voltage
wave length
a,
C
k, / k1 / k2,3 /k9-12 / e1,2
G
G
q
R
I
tan
f
g
L
L
Ris
Z
ZL
Zi
Zr
l
p
m
C
M
a n, n
p
P
rk
r
r
R
s
t
v
U
s-1
dB (Np)
dB/km (Np/km)
F/km
pF
Sm/mm
mS/km
S/km
mm
/km
A
Hz
s/km
mH/km
H/km
Mkm
rad/km
km
dB (Np)
nH
nF/km
mH/km
dB (Np)
s/km
W
/km
mm/m
C
bit/s
V
m
Unit
1/second
dezibel (neper)
dezibel (neper)/km
farad/km
pikofarad
siemensmeter/mm
millisiemens/km
siemens/km
millimeter
ohm/km
ampere
hertz
second/km
millihenry/km
henry/km
megaohmkilometer
rad/km
ohm
ohm
ohm
ohm
kilometer
dezibel (neper)
nanohenry
nanofarad/km
millihenry/km
dezibel (neper)
second/km
watt
ohm/km
ohm mm/m
degree celsius
bit/second
volt
meter
resistance at t C in Ohm
resistance at 20C in Ohm
temperature in C
0.00393 for Cu or 0.00403 for Al
Angular frequency
Dissipation factor
()
100
()
()
L
C
inductivity (H/km)
mutual capacitance (F/km)
(Np/km)
R
G
General
Information
(dB/km)
(Np/km)
101
Shifting Guideline
Bending radius
When laying and bending the cables as well as at the mounting points (e.g. brackets) the bending radius R may not come up to those
below stated. When forming out the cables during the assembly of appropriate treatment the minimum bending radius may be reduced at
the most to half of the indicated values.
Cable typ
installation cables, switchboard cables
Bending radius R
minimum value
7.5 x DA
10 x DA
Installation temperature
For the transfer not the ambient temperature but the temperature of the cable is determining. With low ambient temperatures cables can
be warmed up before shifting by suitable measures in such a way that the cable inside is not cooling under the permissible shifting temperature during the entire shifting procedure. Stress and jerks as well as stress by impact are to be avoided at low temperatures. The pulling speed of the cables should be as even as possible.
temperature range during installation:
cables with Polyethylene sheath (PE)
cables with Polyvinylchlorid sheath (PVC)
-20C up to +50C
-5C up to + 50C
The tensile stress indicated in the following tables applies uniformly to all for with guaranteeing tensile strength armouring cable, with
which is included the cable core frictional connected with the cable sheath - either over a tie rod with pulling eye or a firmly mounting
pulling trunk.
Number of
cores
Conductor diam.
4
5
8
12
16
21
27
33
40
48
56
65
75
80
96
108
114
133
147
154
176
200
102
0.9
100
150
250
350
500
650
800
1000
1200
1450
1650
1950
2200
2350
2800
3100
3250
3700
4000
4200
4700
5300
1.4
300
400
600
900
1200
1500
1900
2300
2700
3200
3700
4300
4800
5100
6000
6800
7100
7900
8600
8900
9900
11000
1.8
500
650
1000
1450
1900
2400
3100
3700
4400
5300
5800
6700
7600
8000
9200
10000
10600
12000
13000
13500
15200
17000
Shifting Guideline
Tensile strength of telecommunication outdoor cables with guaranteeing tensile strength resistance
Number of
double cores
Conductor diam.
5
6
10
20
30
40
50
60
70
80
100
120
150
200
250
300
350
400
500
600
700
800
1000
1200
1500
2000
0.4
250
300
400
500
650
750
850
1000
1100
1400
1600
2000
2600
3300
3900
4300
4900
5900
6800
7600
8400
9800
11000
12500
14400
0.6
350
400
500
700
950
1200
1500
1700
2000
2300
2800
3400
4100
5200
6400
7400
8600
9600
11500
13200
14500
15500
17500
19000
0.8
600
1000
1500
2000
2500
2900
3400
3800
4600
5400
6600
8500
10000
11500
13000
14500
17000
19000
20500
21500
0.9
700
1300
1900
2500
3000
3500
4100
4600
5700
6600
8000
10000
12000
13500
15000
16300
18700
1.2
1200
2300
3200
4100
5000
6000
6700
7500
9000
10500
12500
15700
18800
20000
1.4
1600
2800
4000
5200
6400
7500
8500
9500
11400
The values in the tables above refer to unarmoured cables with no guaranteeing tensile strength armouring. If higher traction loads are
necessary, cables with a a garanteeing tensile strength armouring (steel round or rectangular wire) are to be planned.
General
Information
For the calculation of the tensile load for such cables applies an approximate value of 12 daN for each mm2 steel cross section.
103
Common Explanations
Pictograms Copper Cables
All datasheets are signed with common pictograms, which describe the cable make up and will lighten the localisation of the most applicable cable type.
Mutual capacitance
C35
C38
C42
C50
C52
C55
C60
0,4
0,5
0,6
0,8
triple
quad
0,9
1,0
1,2
1,4
1,8
Cable elements
core
pair
quintuple
DC
2-4
DC
4-8
DC
n
Filling
unfilled
petrol jelly
Fllnidz
104
foil
copper braid
or tape
copper wires
Common Explanations
Pictograms Fiber Optic Cables
Construction
metal-free
longitudinally water-tight
Application
indoor cable
outdoor cable
Resistance to
break-down
[kV/mm]
Spec. volume
resistance
[cm]
Continous possible
operating temperature
dauernd [C]
25
25
70
85
60
1013
1015
1017
1017
1017
20
10
50
50
50
Material
Operating temperatur
(short time)
[C]
Inflammability
+100
+100
+100
+120
+90
+120
+120
+110
+130
+110
self-extinguishing
self-extinguishing
inflammable
inflammable
inflammable
Material
Waterabsorption
%
Weatherproof
Chemical
resistance
(general)
Radioresistance
x106 rad
0.4
0.4
0.1
0.1
0.1
good
good
good
limited
good
limited
limited
limited good
limited good
limited good
17
17
19
19
19
Material
Relative
permittivity
Density
58
34
2.3
2.3
1.6
to
to
to
to
to
+70
+70
+70
+90
+70
[g/cm3]
Tensile
strength
[MPa]
Breaking
elongation
%
Lettersymbol
1.45
1.4
0.92
0.945
0.65
15
20
20
25
10
250
200
400
500
500
Y
Y
2Y
2Y...HD
02Y
General
Information
up
up
up
up
up
105
Common Explanations
RAL-colour code
106
colournumber
colour
hueexpresion
colournumber
colour
hueexpresion
1001
1012
1013
1014
1015
1016
1019
1021
2000
2002
2003
2004
3000
3002
3004
3015
4001
4003
4005
5002
5010
5012
5014
beige
yellow
white
ivory
beige
yellow
beige
yellow
orange
orange
orange
orange
red
red
red
pink
violet
violet
violet
blue
blue
blue
blue
beige
lemon yellow
oyster white
ivory
light ivory
sulfur yellow
grey beige
rape yellow
yellow orange
vermilion
pastel orange
pure orange
flame red
carmine red
purple red
light pink
red lilac
hether violet
blue lilac
ultramarine blue
gentian blue
light blue
pigeon blue
5015
5019
6000
6001
6003
6005
6010
6018
6027
7000
7001
7021
7032
7035
7037
8003
8011
8014
8024
9001
9005
9007
9010
light blue
blue
green
green
green
green
green
green
turquoise
grey
grey
grey
grey (ptt grey)
grey
grey
brown
brown
brown
brown
white
black
silver grey
white
sky blue
capri blue
patina green
emerald green
olive green
moss green
grass green
yellow green
light green
squirrel grey
silver grey
black grey
pebble grey
light grey
dusty grey
clay grey
nut brown
sepia brown
beige brown
cream
jet black
grey aluminium
pure white
m
t = 60 +
25
Hereby materials are used, which do not contain halogens (e.g. chlorine)
and which do not set free corrosive gases in the case of fire. Also the
proportion of toxic gases is reduced to a minimum, and smoke development and fire away line are hardly still available or possible. Designation notes at the cable are e.g. the abbreviations FRNC or LSOH.
In detail these designations are meaning:
FR flame retardant
(fire-away-line-restraining)
NC non corrosiv
(no corrosive constituents)
LS low smoke
(low smoke development)
0H zero halogen (halogen-free)
Another big advantage by using such materials is, that the free view
on gears and escape routes is kept. Please note that you have to take
care that such kinds of materials are also used by other products,
e.g. power cables or cable run channels.
Analysis
The test is considered as positively passed if the sample did not burn
or the flames automatically go out and the fire damage does not
reach the upper end of the sample.
Fire-pure e.g. soot lining and colour modification are not does claimed.
General
Information
107
Testing method 1
Testing methode 3
Preparation (fig. 2)
The samples are arranged at the test rack as follows:
Telecommunication cables and cords as well as control cables and
cords with an outside diameter 30 mm without distance.
The number has to be selected in such a way that the grouping width
results of min.180 mm; the distance of the outside samples to the lateral side piece of the ladder should be approx. 90 up to 120 mm;
mounting of the samples with steel wires; the test rack is inserted
vertically into the suspension of the furnace. Dimensions of the
furnance as well as air volume and temperature are exactly regulated.
Burner, 77.74.8 l/min propane and 13.50.5 l/h air measured at
20C and 1 bar.
Before starting the test the test set-up has to be conditioned at room
temperature for mind. 16 h.
Flame of the gas burner has to be fixed in an angle of 90 approx. 600
mm above the lower sample end, in a distance of 75 mm.
Execution
Duration of the flaming action at least min. 20 minutes
Fig.1
Fig.2
The test according to test type 3 shows very realistically the possible
fire in a vertical duct.
Analysis
The test is considered as positively passed if the sample did not burn
or the flames automatically go out and the fire damage does not
reach the upper end of the sample.
Fire-pure e.g. soot lining and color modification are not does claimed.
108
identification
number
drum
dimesion
flange-diameter
D
[mm]
barrel-diameter width
d
B
[mm]
[mm]
drumweight
aprrox. [kg]
051
E6
061
071
E8
081
091
E10
101
E12
121
E14
141
E16
161
162
E18
181
182
E20
201
202
E22
221
222
E24
250
251
252
E26
E28
281
E30
05
06
06
07
08
08
09
10
10
12
12
14
14
16
16/8
16/10
18
18/10
18/12
20
20/12
20/14
22
22/14
22/16
24
25/14
25/16
25/18
26
28
28/18
30
500
600
630
710
800
800
900
1000
1000
1200
1250
1400
1400
1600
1600
1600
1800
1800
1800
2000
2000
2000
2200
2240
2240
2400
2500
2500
2500
2600
2800
2800
3000
150
300
315
355
400
400
450
550
500
700
630
850
710
1000
800
1000
1150
1000
1250
1300
1250
1400
1450
1400
1600
1600
1400
1600
1800
1700
1800
1800
1900
400
315
400
400
560
560
666
660
844
835
835
825
1035
1030
1140
1130
1140
1130
1120
1280
1270
8
20
13
25
40
31
47
80
71
150
144
200
175
350
280
271
500
380
352
600
550
544
700
710
738
900
875
900
909
1100
1400
1175
1600
470
450
415
500
560
500
670
700
690
790
860
870
870
970
1060
1100
1110
1060
1100
1190
1310
1345
1330
1410
1475
1380
1450
1450
1475
1450
1650
1590
250
400
600
800
900
1700
2000
3000
3000
4000
4000
5000
5000
6000
6000
7500
7500
7500
10000
10000
General
Information
109
cable-diameter 6 - 23 mm
11
12
13
14
15
16
17
20
21
22
93
165
219
402
576
1139
1352
2435
1849
2831
2772 2405 2076 1985
90
159
211
387
485
991
1304
2172
1600
2527
1704
122
167
315
468
856
1145
1931
1539
2248
1636
121
141
161
162
181
182
201
202
221
222
250
251
252
281
282
110
19
151
285
365
688
839
1608
1235
1867
1295
2522
2023
32
33
34
209
428
537
866
655
1009
779
1500
1081
2035
1553
2978
2976 2893 2558 2491
2944 2848 2474 2398 2327 2004 1948
204
352
451
846
638
985
635
1289
1052
1984
1511
2908
2428
1896
344
441
828
622
962
618
1257
1024
1726
1264
2605
2134
1614
116
228
299
668
814
1419
1053
1650
1093
2218
1732
221
290
567
700
1244
1020
1450
1057
2150
1675
2861
2881 2493 2408 2329
215
282
551
681
1211
860
1409
1023
1879
1418
2777
2000
254
437
341
511
315
763
565
1085
699
1603
1199
942
1956
1401
249
430
334
502
309
749
553
1064
684
1574
1175
923
1693
1373
245
422
328
492
302
611
542
890
670
1373
1153
904
1661
1345
240
415
321
484
296
600
531
874
657
1349
1131
886
1630
1319
23
117
161
304
389
827
999
1869
1324
2172
1394
2953
2629 2524 2176
2992
cable-diameter 24 - 41 mm
29
30
31
209
226
462
663
1180
835
1371
851
1826
1374
2450
1939
162
220
450
564
1028
811
1197
825
1583
1333
2383
1882
214
438
550
1003
789
1166
802
1540
1295
2089
1598
35
36
37
38
39
40
41
336
431
707
607
824
603
1227
998
1685
1232
2547
2083
1573
2890
2737 2663 2594 2242
329
422
692
493
806
587
1041
816
1646
1201
2271
2035
1534
2822
2186
265
348
678
482
788
466
1017
796
1418
1170
2223
1774
1286
2759
2134
259
341
664
471
772
454
994
777
1386
960
1969
1735
1255
2432
2084
254
334
560
460
653
444
972
759
1356
938
1930
1697
1226
2379
1780
249
327
549
451
640
434
812
742
1328
917
1892
1466
1199
2329
1740
244
264
539
356
627
424
795
590
1130
896
1664
1435
1172
2036
1702
18
1113
845
637
472
386
314
253
237
189
179
140
134
102
97
2024 1481 1064
892
677
564
468
385
364
297
239
228
218
172
2755 2340 1463 1152
980
761
643
542
454
430
358
294
281
228
2731 2202 1768 1404 1206 1032
881
749
632
603
505
485
2866 2349 1912 1540 1339 1159 1000
860
736
705
599
2727 2255 1991 1756 1545 1355 1784
2967 2479 2205 1959 1737 1535
2722
2903 2543 2220 2123
cable-diameter 42 - 59 mm
47
48
49
50
51
52
53
54
55
56
57
58
59
187
408
330
325
319
314
310
305
243
238
234
230
226
222
218
214
151
149
146
475
386
380
373
367
361
356
280
276
271
267
290
285
279
274
195
191
188
184
181
178
175
589
578
568
558
442
435
428
421
414
408
401
405
397
389
382
375
369
362
356
254
249
245
858
842
828
678
666
655
644
634
624
614
488
644
632
620
474
465
457
449
441
434
426
419
1326 1144 1125 1107 1089 1072
912
898
885
872
860
1110
931
914
898
883
869
713
701
690
679
668
708
694
681
668
656
645
633 48S
477
469
461
1600 1367 1343 1320 1298 1276 1073 1073 1039 1022 1006
1293 1065 1046 1026 1008
990
973
779
766
753
741
144
263
172
304
241
480
413
719
658
454
991
729
142
260
169
300
237
473
29S
709
649
446
815
718
162
181
182
201
202
221
222
250
251
252
281
282
139
256
167
295
234
466
290
699
639
439
803
707
137
252
164
291
230
460
286
689
509
433
791
696
135
190
103
287
226
453
281
680
501
426
780
534
133
187
101
282
223
447
277
671
494
420
769
526
131
184
100
279
220
441
273
663
487
300
759
518
cable-diameter 60 - 77 mm
65
66
67
68
69
70
71
72
73
74
75
76
77
129
182
98
275
216
335
269
541
481
296
748
511
128
180
97
271
213
330
265
534
474
292
739
503
95
267
134
326
261
528
468
288
589
496
94
264
132
321
258
521
462
283
581
490
93
186
131
317
254
515
456
279
574
483
91
184
129
313
251
509
450
276
566
476
90
182
127
309
247
503
343
272
559
470
89
179
125
305
244
497
338
268
552
464
88
177
124
301
241
491
334
265
545
458
86
175
122
298
152
486
330
261
539
452
85
173
120
294
150
480
326
258
532
447
84
170
119
291
148
380
322
255
526
320
83
168
117
287
146
375
318
252
520
316
201
202
221
222
250
251
252
281
282
166
116
284
144
371
314
248
514
312
164
114
281
143
367
311
245
508
308
163
113
278
141
363
307
242
503
305
161
112
196
139
360
304
240
383
301
159
110
194
137
356
300
237
379
297
83
84
85
86
87
88
89
90
91
92
93
157
109
192
136
352
297
234
375
294
108
190
134
349
294
148
371
291
106
188
133
345
291
146
367
287
105
186
131
342
288
144
363
284
104
184
130
338
285
143
359
281
103
182
128
335
202
143
355
278
102
180
127
332
200
140
352
275
101
178
125
329
198
138
348
272
99
176
124
248
196
137
345
269
98
175
123
245
194
135
341
266
97
173
121
243
192
134
338
264
94
95
120
119
190
132
335
261
188
131
331
258
General
Information
identification
number
cable-diameter 78 - 95 mm
111
Railway Cables
Note
112
Terms of Delivery
General terms of delivery
for cables, furnitures and insulated cords from Pengg Kabel GmbH, later named Seller.
1.
Scope
1.1. These General Terms shall govern legal transactions between business enterprises, namely the delivery of commodities and, mutatis mutandis, the rendering of services. Software transactions are with precedence governed by the 6.
Software Conditions issued by the Austrian Electrical and Electronics Industry 6.1.
Association, assembly work by the Terms and Conditions for Assembly Work
issued by the Austrian Power Current and Light Current Engineering Industry
and/or (where applicable) the Terms and Conditions for the Assembly of Elec- 6.2.
trical Equipment used in Medicine issued by the Austrian Electrical and Electronics Industry (the current versions are available at www.feei.at).
1.2. Any departure from the terms and conditions mentioned in 1.1 above shall be
7.
valid only if expressly accepted in writing by Seller.
7.1. Unless otherwise agreed, one third of the purchase price shall fall due at the
2.
Submission of offers
time of receipt by Buyer of the order confirmation of Seller, one third after half
2.1. Sellers offers shall be deemed offers without engagement.
the delivery period has elapsed and the balance at the time of delivery. Irre2.2. Tender documents and project documentation must not be duplicated nor
spective thereof the turnover tax comprised in the amount of the invoice shall
made available to third parties without the permission of Seller. They may be
be paid within 30 days of the invoice date. If bankruptcy proceedings are insticlaimed back at any time and shall be returned to Seller immediately if the order
tuted against the assets of Buyer or if an application for bankruptcy proceeis placed elsewhere.
dings is not granted for insufficiency of assets, deliveries shall only be made
against cash in advance.
3.
Conclusion of contract
3.1. The contract shall be deemed concluded upon written confirmation by Seller of 7.2. In the case of part settlements the individual part payments shall fall due upon
receipt of the respective invoices. The same shall apply to amounts invoiced for
an order received or upon dispatch of a delivery.
additional deliveries or resulting from additional agreements beyond the scope
3.2. Particulars appearing in catalogues, folders etc. as well as any oral or written
of the original contract, irrespective of the terms of payment agreed upon for
statements shall only be binding if Seller makes express reference to them in
the principal delivery.
the confirmation of the order.
7.3. Payment shall be made without any discount free Sellers domicile in the agre3.3. Subsequent amendments of or additions to the contract shall be subject to
ed currency. Drafts and checks shall be accepted on account of payment only,
written confirmation.
with all interest, fees and charges in connection therewith (such as collection
and discounting charges) to be borne by Buyer.
4.
Prices
4.1. Prices shall be quoted ex works or ex Sellers warehouse without VAT, packing 7.4. Buyer shall not be entitled to withhold or offset payment on the grounds of any
warranty claims or other counterclaims.
and packaging, loading, disassembly, take-back and proper recycling and disposal of waste electrical and electronic equipment for commercial purposes as 7.5. Payment shall be deemed to have been effected on the date at which the amodefined by the Ordinance Regulating the Handling of Waste Electrical Equipunt in question is at Sellers disposal.
ment. Buyer shall be liable for any and all charges, taxes or other duties levied
7.6.
If
Buyer fails to meet the terms of payment or any other obligation arising from
in respect of delivery. If the terms of delivery include transport to a destination
this or other legal transactions, Seller may without prejudice to his other rights
designated by Buyer, transport costs as well as the cost of any transport insurance desired by Buyer shall be borne by the latter. Delivery does not, however,
a) suspend performance of his own obligations until payments have been made
include unloading and subsequent handling. Packaging materials will be taken
or other obligations fulfilled, and exercise his right to extend the period of deliback only by express agreement.
very to a reasonable extent,
4.2. Seller reserves the right to modify prices if the order placed is not in accordance with the offer submitted.
b) call in debts arisen from this or any other legal transactions and charge
default interest amounting to 1.25 % per month plus turnover tax for these
amounts beginning with the due dates, unless Seller proves costs exceeding
this.
4.4. In carrying out repair orders, Seller shall provide all services deemed expedient
and shall charge Buyer for the same on the basis of the work input and/or
expenditures required. The same holds for any services or additional services
the expediency of which becomes apparent only as the repair order is execu- 7.7.
ted. In such an event special notification of Buyer shall not be required.
7.8.
4.5. Expenses for estimates of costs of repair and maintenance or for expert valuations shall be invoiced to Buyer.
5.
Delivery
5.1. The period allowed for delivery shall commence at the latest of the following
dates:
a) the date of order confirmation by Seller;
b) the date of fulfilment by Buyer of all the conditions, technical, commercial
and other, for which he is responsible;
c) the date of receipt by Seller of a deposit or security due before delivery of the
goods in question.
c) only perform other legal transactions against cash in advance in the case of
qualified insolvency, in other words, following two delays in payment.
In any case Seller has the right to invoice all expenses arising prior to a lawsuit,
especially reminder charges and lawyers fees.
Discounts or bonuses are subject to complete payment in due time.
Seller retains title to all goods delivered by him until receipt of all amounts invoiced including interests and charges.
Buyer herewith assigns his claim out of a resale of conditional commodities,
even if they are processed, transformed or combined with other commodities,
to Seller to secure the latters purchase money claim. In the case of resale granting respite Buyer shall have the power of disposal of the product under retention of ownership only with the proviso that upon reselling Buyer notifies the
secondary buyer of the assignment for security or enters the assignment in his
account books. Upon request Buyer has to notify the assigned claim and the
debtor thereof to Seller, and to make all information and material required for
his debt collection available and to notify the assignment to the third-party debtor. If the goods are attached or otherwise levied upon, Buyer shall draw attention to Sellers title and immediately inform Seller of the attachment or levy.
5.2. Buyer shall obtain whatever licences or approvals may be required from authoWarranty and acceptance of obligation to repair defects
rities or third parties for the construction of plant and equipment. If the granting 8.
of such licences or approvals is delayed for any reason the delivery period shall 8.1. Once the agreed terms of payment have been complied with, Seller shall, subbe extended accordingly.
ject to the conditions hereunder, remedy any defect existing at the time of
acceptance of the article in question whether due to faulty design, material or
5.3. Seller may carry out, and charge Buyer for, partial or advance deliveries. If delimanufacture, that impairs the functioning of said article. From particulars
very on call is agreed upon, the commodity shall be deemed called off at the
appearing in catalogues, folders, promotional literature as well as written or oral
latest one year after the order was placed.
statements which have not been included in the agreement no warranty obli5.4. In case of unforeseeable circumstances or circumstances beyond the parties
gations may be deduced.
control, such as all cases of force majeure, which impede compliance with the
agreed period of delivery, the latter shall be extended in any case for the dura- 8.2. Unless special warranty periods operate for individual items the warranty period shall be 12 months. These conditions shall also apply to any goods suption of such circumstances; these include in particular armed conflicts, official
plied, or services rendered in respect of goods supplied, that are firmly attainterventions and prohibitions, delays in transport or customs clearance, damached to buildings or the ground. The warranty period begins at the point of pasges in transit, energy shortage and raw materials scarcity, labour disputes, and
sage of risk acc. to paragraph 6.
default on performance by a major component supplier who is difficult to replace. The aforesaid circumstances shall be deemed to prevail irrespective of 8.3. For improved or exchanged parts, the warranty period shall start again, but
whether they affect Seller or his subcontractor(s).
shall end in any case 6 months after the original warranty period has expired.
5.5. If a contractual penalty for default of delivery was agreed upon by contracting 8.4. If delivery or the performance of services is delayed for reasons outside the
parties when the contract was concluded, it shall be executed as follows, and
control of Seller, the warranty period shall begin 2 weeks after Seller is ready
any deviations concerning individual items shall not affect the remaining provito deliver or perform services.
sions: Where delay in performance can be shown to have occurred solely
through the fault of Seller, Buyer may claim for each completed week of delay 8.5. The foregoing warranty obligations are conditional upon the Buyer giving within
a reasonable period notice in writing of any defects that have occurred and
an indemnity of at most one half of one per cent, a total of no more than 5 %,
such notice reaching the Seller. Buyer shall prove within a reasonable period
however, of the value of that part of the goods to be delivered which cannot be
General
Information
4.3. Prices are based on costs obtaining at the time of the first quotation. In the
event that the costs have increased by the time of delivery, Seller shall have the
right to adjust prices accordingly.
113
Terms of Delivery
General terms of delivery (continued)
the presence of a defect, in particular he shall make available within a reasonable period to Seller all material and data in his possession. Upon receipt of
such notice Seller shall, in the case of a defect covered by the warranty under
8.1 above, have the option to replace the defective goods or defective parts
thereof or else to repair them on Buyers premises or have them returned for
repair, or to grant a fair and reasonable price reduction.
8.6. Any expenses incurred in connection with rectifying defects (e. g. expenses for
assembly and disassembly, transport, waste disposal, travel and site-to-quarters time) shall be borne by Buyer. For warranty work on Buyers premises
Buyer shall make available free of charge any assistance, hoisting gear, scaffolding and sundry supplies and incidentals that may he required. Replaced
parts shall become the property of Seller.
8.7. If an article is manufactured by Seller on the basis of design data, design drawings, models or other specifications supplied by Buyer, Sellers warranty shall
be restricted to non-compliance with Buyers specifications.
8.8. Sellers warranty obligation shall not extend to any defects due to assembly
and installation work not undertaken by Seller, inadequate equipment, or due
to non-compliance with installation requirements and operating conditions,
overloading of parts in excess of the design values stipulated by Seller, negligent or faulty handling or the use of inappropriate materials, nor for defects
attributable to material supplied by Buyer. Nor shall Seller be li- able for damage due to acts of third parties, atmospheric discharges. Excess voltage and
chemical influences. The warranty does not cover the replacement of parts
subject to natural wear and tear. Seller accepts no warranty for the sale of used
goods.
8.9. The warranty shall lapse immediately if, without written consent of Seller, Buyer
himself or a third party not expressly authorised undertakes modifications or
repairs on any items delivered.
8.10. Claims acc. to 933b ABGB are struck by the statute of limitation with lapse
of the period mentioned under point 8.2.
8.11. The provisions of sub-paragraphs 8.1 to 8.10 shall apply, mutatis mutandis, to
all cases where the obligation to repair defects has to be accepted for other
reasons laid down by law.
9.
Withdrawal from contract
9.1. Buyer may withdraw from the contract only in the event of delays caused by
gross negligence on the part of Seller and only after a reasonable period of
grace has elapsed. Withdrawal from contract shall be notified in writing by registered mail.
9.2. Irrespective of his other rights Seller shall be entitled to withdraw from the contract
a) if the execution of delivery or the inception or continuation of services to be
rendered under the contract is made impossible for reasons within the responsibility of Buyer and if the delay is extended beyond a reasonable period of
grace allowed;
b) if doubts have arisen as to Buyers creditworthiness and if same fails, on Sellers request, to make an advance payment or to provide adequate security
prior to delivery, or
c) if, for reasons mentioned in 5.4, the period allowed for delivery is extended
by more than half of the period originally agreed or by at least 6 months, or
d) if Buyer does not or does not properly meet the obligations imposed as per
paragraph 13.
9.3. For the reasons given above withdrawal from the contract shall also be possible in respect of any outstanding part of the delivery or service contracted for.
9.4. If bankruptcy proceedings are instituted against Buyer or an application for
bankruptcy proceedings is not granted for insufficiency of assets, Seller may
withdraw from the contract without allowing a period of grace. If this withdrawal is taken, it shall take effect immediately upon the decision that the business will not be continued. If the business will be continued, a withdrawal shall
not take effect until 6 months after the institution of bankruptcy proceedings or
after an application for bankruptcy proceedings has not been granted for insufficiency of assets. In any case, the contract shall be terminated immediately
unless the bankruptcy law to which Buyer is subject conflicts with this or if termination of the contract is necessary to prevent significant damages to Seller.
9.5. Without prejudice to Sellers claim for damages including expenses arising prior
to a lawsuit, upon withdrawal from contract any open accounts in respect of
deliveries made or services rendered in whole or in part shall be settled according to contract This provision also covers deliveries or services not yet accepted by Buyer as well as any preparatory acts performed by Seller. Seller shall,
however, have the option alternatively to require the restitution of articles already delivered.
9.6. Withdrawal from contract shall have no consequences other than those stipulated above.
9.7. The assertion of claims on the ground of laesio enormis, error, or lapse of purpose by the Buyer is excluded.
10.
10.2. The Buyer incorporated in Austria shall ensure that the Seller is provided with
all information necessary to meet the Sellers obligations as
manufacturer/importer, particularly according to 11 and 24 of the Ordinance
Regulating the Handling of Waste Electrical Equipment and the Waste Management Act.
10.3. The Buyer incorporated in Austria is liable vis--vis the Seller for any dam- age
and other financial disadvantages incurred by Seller due to Buyers failure to
meet or fully meet his financing commitment or any other obligations according
to Article 10. The Buyer shall bear the burden of proof of performance of this
obligation.
11.
Sellers liability
11.1. Outside the scope of the Product Liability Act, Seller shall be liable only if the
damage in question is proved to be due to intentional acts or acts of gross negligence, within the limits of statutory provisions. Seller's total liability in cases of
gross negligence is limited to the net value of the order or EUR 500,000, depending on which amount is lower.
11.2. For each incident of damage, Seller shall be liable for 25% of the net value of
the order or EUR 125,000, depending on which amount is lower.
11.3. Seller shall not be liable for damage due to acts of ordinary negligence nor for
consequential damages or damages for pure economic loss, indirect damages,
loss of production, financing costs, costs for replacement energy, loss of energy, data or information, loss of profits, loss of savings or interest, or damage
resulting from third-party claims against buyer.
11.4. Seller shall not be liable for damages in case of non-compliance with instructions for assembly, commissioning and operation (such as are contained in
instructions for use) or non-compliance with licensing requirements.
11.5. Claims that exceed the contractual penalties that were agreed on are excluded
from the respective title. The provisions of paragraph 11 apply exclusively for
all claims by Buyer against Seller, regardless of the legal basis or entitlement,
and also apply to all employees, subcontractors and subsuppliers of Seller.
12.
12.1. Buyer shall indemnify Seller and hold him harmless against any claims for any
infringement of industrial property rights raised against him if Seller manufactures an article pursuant to any design data, design drawings, models or other
specifications made available to him by Buyer.
12.2. Design documents such as plans and drawings and other technical specifications as well as samples, catalogues, prospectuses, pictures and the like shall
remain the intellectual property of Seller and are subject to the relevant statutory provisions governing reproduction, imitation, competition etc. The provisions of 2.2 above shall also cover design documents.
13.
13.1. When passing on goods delivered by Seller to third parties (as well as any related documentation, regardless of the method of provision or the services performed by Seller [including technical support of any kind]), Buyer must comply
with the applicable regulations of national and international (re-)export provisions. In any case, Buyer must observe the (re-)export provisions of Seller's
country of residence, the European Union and the United States of America.
13.2. If necessary for export controls, Buyer must provide Seller with all necessary
information immediately after being requested to do so, for example, information about the final recipient, final destination and purpose of the goods or services.
14.
General
Should individual provisions of the contract or of these provisions be invalid the
validity of the other provisions shall not be affected. The invalid provision shall
be replaced by a valid one, which comes as close to the target goal as possible.
15.
16.
Proviso
The execution of the contract by Seller is subject to the condition that there are
no obstacles standing in the way of execution due to national or international
(re-)export provisions, and especially no embargos and/or other sanctions.
10.1. The Buyer of electrical/electronic equipment for commercial purposes, incorporated in Austria, is responsible for the financing of the collection and treatment of waste electrical and electronic equipment as defined by the Ordinance
Regulating the Handling of Waste Electrical Equipment, if he is himself the user
of the electrical/electronic equipment. If the Buyer is not the end user, he shall
transfer the full financial commitment to his customer by agreement and furnish
proof thereof to the Seller.
114