Professional Documents
Culture Documents
MINIATURE RELAY
DS2Y RELAYS
FEATURES
TYPICAL APPLICATIONS
1. 2 Form C contact
2. High sensitivity-200 mW nominal
operating power
3. High breakdown voltage
1500 V FCC surge between open
contacts
4. DIP-2C type matching 16 pin IC socket
5. Sealed construction
1. Telecommunication equipment
2. Office equipment
3. Computer peripherals
4. Security alarm systems
5. Medical equipment
ORDERING INFORMATION
DS2Y-S
Operating function
Nil: Single side stable
Nominal coil voltage
DC 1.5, 3, 5, 6, 9, 12, 24, 48 V
Polarity
Nil: Standard polarity
R: Reverse polarity
Notes: 1. Reverse polarity types available (add suffix-R)
2. UL/CSA approved type is standard.
TYPES
Contact arrangement
2 Form C
1.5V DC
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
ds_61005_en_ds2y: 010611J
DS2Y
RATING
1. Coil data
Single side stable type
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
1.5V DC
132.7mA
11.3
3V DC
5V DC
6V DC
9V DC
12V DC
24V DC
48V DC
66.7mA
40mA
33.3mA
22.2mA
16.7mA
8.3mA
6.3mA
45
125
180
405
720
2,880
7,680
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
70%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20C 68F)
10%V or more of
nominal voltage
(Initial)
Nominal operating
power
200mW
200%V of
nominal voltage
300mW
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Initial contact resistance, max.
Contact material
Max. switching power
Max. switching voltage
Max. switching current
Max. carrying current
Minimum operating power
Nominal operating power
Specifications
2 Form C
Max. 50 m (By voltage drop 6 V DC 1A)
Ag+Au clad
60 W, 62.5 VA (resistive load)
220 V DC, 250 V AC
2A
3A
Approx. 98 mW (147 mW: 48 V)
Approx. 200 mW (300 mW: 48 V)
Electrical
characteristics
Shock resistance
Mechanical
characteristics
Expected life
Conditions
Unit weight
* Refer to 6. Usage, Storage and Transport Conditions in AMBIENT ENVIRONMENT section in Relay Technical Information.
ds_61005_en_ds2y: 010611J
DS2Y
REFERENCE DATA
1. Maximum switching capacity
1,000 V
100 V
10 V
Operate time
Release time
3A
30
4
2A
Time, ms
Temperature rise, C
Contact voltage
0A
Mean value
Mean value
2
20
1
10 mA
10 A
100 mA
100
1A
Switching current
110
Coil applied voltage, %V
TEST METHOD
1. Apply nominal voltage to No. (1) and (3) DS2Y
relays.
2. Measure pick-up voltage and drop-out voltage of
No. (2) relay when inter-relay distance ( ) changes.
TEST METHOD
1. Apply nominal voltage to No. (1) and (3) DS2Y
relays.
2. Measure pick-up voltage and drop-out voltage of
No. (2) relay when inter-relay distance ( ) changes.
(1)
OFF
10
(2)
(3)
OFF
Pick-up/Drop-out voltage, V
Pick-up/Drop-out voltage, V
8
ON
ON
Pick-up voltage
6
OFF
OFF
4
Drop-out voltage
ON
ON
80
100
120
Coil applied voltage, %V
10
(1)
OFF
(2)
(3)
OFF
8
Pick-up voltage
ON
ON
OFF
OFF
ON
ON
4
Drop-out voltage
2
5
10
15
.197 .394 .591
Inter-relay distance, mm inch
5
10
15
.197 .394 .591
Inter-relay distance, mm inch
CAD Data
Data from our Web site.
Download CAD
External dimensions
(Deenergized position)
8-0.9 dia.
8-.035 dia.
9.9
.390
20
.787
2.54
.100
9.3
.366
5.08 5.08
.200 .200
7.62
.300
2.0
.078
0.6
.024
5.6
.220
7.62
.300
9
11
13
N.O. N.C. COM
16
+
1
2.54
.100
0.6
.024
0.6
.024
3.4
.134
7.62
.300
0.3
.012
Direction indication*
ds_61005_en_ds2y: 010611J