Water cooled water chillers


WHZ 024.2047.2
Cooling capacity from 85 to 164 kW
50 Hz - refrigerant: HFC 407 C

McQuay is participating in the Eurovent Certification Programme.


Product are as listed in the Eurovent Directory of Certified Products
and on the web site www.eurovent-certification.com

McQuay water cooled water chiller


McQuay Intl introduces their newest water cooled water
chiller type WHZ equipped with Scroll compressors and
electronic control system. McQuay have once again
succeeded in developing a high quality product with
extraordinary performance which is able to satisfy HVAC
application, industrial refrigeration an icestore application.
For more than 60 years, McQuay have designed and built
successful line of products.The latest technology is
included in the new WHZ chiller range equipped with Scroll
compressor and unsurpassed advanced features. All units
are equipped with electronic control device control which
optimises the unit operation also improving the interface
with devices for remote monitoring.

control and a serial output board are available as option for


a supervisor connection.

General characteristics
Structure
The chiller is equipped with brackets directly installed on
heat exchangers. The evaporator and the suction piping
are appropriately insulated to prevent condensation.

Scroll Compressors

Compressors: unit model WHZ 024.2 is equipped with two


single compressors, unit model WHZ 032.2 047.2 install
The McQuay WHZ chillers use the most reliable and two tandem scroll hermetic compressors. Electric motors
efficient components in the industry. Scroll compressors are DOL starting type.
offer an operating economy that at partial load conditions is
uncomparable with the most aggressive competitors. The Evaporator
unloading system with multiple capacity steps reduce
The evaporator is a direct expansion shell-and-tube type
allows the electrical consumption to the plant requirement.
constructed with a carbon steel shell and seamless high
The use of a single evaporator provided with multiple
efficiency copper tubes. It is equipped with a baffled shell
refrigerant circuits improves the unit performance at partial
side to ensure the appropriate water flowing outside the
load operation.
tubes obtaining the maximum heat exchange with the
lowest pressure drop. Externally the shell is protected by
Low installation costs
10 mm thickness closed-cell insulation material. Evaporator
All units are completely factory assembled. A rigid steel water connections of victaulic type are equipped with a
base with lifting points permits quick unit rigging. Power water nozzle to be welded on the plant piping system.
and control panel mounted on the shorter side of the unit
determines a more optimized location of unit inside the Condensers
chillers room, allowing easy maintenance and control. WHZ
Condensers are shell and cleanable, through-tube type.
units are fully wired and supplied with a single power
The unit has independent condensers, one per circuit.
connection. Extensive quality control operation tests assure
Each condenser has a carbon steel and seamless,
trouble-free installation and start-up.
integrally finned high efficiency copper tubes, roll expanded
into heavy carbon steel tube sheets. Water heads are
Full factory testing
removable and include vent and drain plugs. Condensers
Pressure vessels tests are performed on all units then come complete with liquid shut-off valve, spring loaded
evacuated and charged with refrigerant HFC 407C. All relief valve.
safety and operating controls are properly checked and
calibrated at the factory. A complete performance test Refrigerant circuits
simulates the given conditions. A second series of tests Each refrigerant circuit is completely independent and
may also be performed at customers presence. Before complete with all control and regulation devices such as:
shipment, each unit is re-checked for pressure and filter driers, liquid sight glass and thermostatic expansion
refrigerant charge control.
valves.

Low operating costs

Code requirements
WHZ units can be manufactured and
accordance with PED code requirements.

Power and starting panel

in Inside the electrical panel is installed a programmable


electronic control, including temperature sensors, keypad
to set and control data protected by a password. All
Reliability
devices are factory installed and wired. The unit controls
The use of scroll compressors together with the most are designed to allow the reading and the updating of data
advanced and efficient control system assures reliable both locally and remotely.
functioning. Each refrigerant circuit comes complete with
multiple safety devices which prevent compressor damage.

Serviceability

certified

Available versions

All multiple compressor units use independent refrigerant


circuits. They permit shut-down, routine maintenance and Water chiller model WHZ is available in three versions:
service of one of the circuit while the others maintain the WHZ ST Standard version equipped with water cooled
condensers
system operation.
WHZ LR Special execution without the water cooled
condensers. The units suitable for remote condenser
Programmable electronic control device
The control device is installed as standard on all water operation are equipped with liquid receivers, one per circuit
cooled chiller series WHZ. It visualises all operating values and with copper tube connection.
and setpoint recorded allowing setting and modifying the WHZ ME Special execution as the previous version but
regulation parameters at a later stage. An infrared remote also without the liquid receivers to be arranged on the
installation.

602 B 04/11 C pag. 2/8

Accessories and options


01 - 100% total heat recovery (R) produced with tube
bundle placed in a single shell with the water condensers.
Heat exchangers heads are provided with 2 connections for
entering/leaving heat recovery water and 2 separate
connections for condensing water.
11 - Compressor thermal relays. Safety device against
compressor motor overloading.
42 - Flow switch. For field installation on evaporator and
condensers pipes to prevent freeze up under low
temperature conditions. It must be wired to the power panel
terminals by the customer.
84 - Rubber antivibration isolators. They are available
for field installation to reduce vibrations transmission
through the unit base.
86 - Sound proof jacket on compressors. Made of
insulated material to reduce the sound noise level of the
compressors (-3 dBA).

Table 1 Operatine limits


HFC 407C
Maximum evap. entering water temp. (without glycol)
Maximum evap. leaving water temp. (without glycol)
Minimum evap. leaving water temp. (with glycol)
Maximum cond. leaving water temp.
Minimum cond. leaving water temp.

C
C
C
C
C

24
16
-8
50
30

Note: Table 1 is referred to 2 passes condenser.

Table 2 Evaporator fouling factors


Fouling factor
m2C / kW

Cooling capacity
correction factor

Power input correction


factor

COP correction factor

0,0440
0,0880
0,1320

1,000
0,986
0,972

1,000
0,992
0,984

1,000
0,994
0,987

Table 3 Condenser fouling factors


Fouling factor
m2C / kW

Cooling capacity
correction factor

Power input
correction factor

COP
correction factor

0,0440
0,0880
0,1320

1,000
0,990
0,981

1,000
1,018
1,036

1,000
0,973
0,945

Table 4 Ethylene glycol correction factors


Air ambient temperature C
Ethylene glycol %
Cooling capacity correction factor
Power input correction factor
Water flow rate correction factor
Water pressure drop correction factor

-3
10
0,991
0,996
1,013
1,070

-8
20
0,985
0,992
1,040
1,129

-14
30
0,972
0,986
1,074
1,181

-22
40
0,961
0,976
1,121
1,263

-33
50
0,946
0,966
1,178
1,308

Table 5 Brine application correction factors


2
0
-2
-4
-6
-8
Glicol/water leaving temperature C
10
20
20
30
30
30
Min. % of ethylene glycol
0,840
0,782
0,726
0,673
0,623
0,575
Cooling capacity correction factor *
0,950
0,940
0,920
0,890
0,870
0,840
Power input correction factor *
* Correction factors have to be applied to performance data at the requested condenser outlet water temperature and 7C leaving water
temperature

602 B 04/11 C pag. 3/8

Sound pressure level


Sound pressure level at 1 m from unit in free field (rif. 2 x 10-5)

Size
standard WHZ

63 Hz

125 Hz

250 Hz

500 Hz

1000 Hz

2000 Hz

4000 Hz

8000 Hz

dBA

024.2
032.2
041.2
047.2
WHZ with
sound-proof
jacket
024.2
032.2
041.2
047.2

63,0
64,0
64,0
64,0

55,5
56,5
56,5
56,5

63,5
64,5
64,5
64,5

75,0
76,0
76,0
76,0

72,5
73,5
73,5
73,5

69,5
70,5
70,5
70,5

68,0
69,0
69,0
69,0

58,5
59,5
59,5
59,5

77,0
78,0
78,0
78,0

63 Hz

125 Hz

250 Hz

500 Hz

1000 Hz

2000 Hz

4000 Hz

8000 Hz

DBA

62,5
63,5
63,5
63,5

55,0
56,0
56,0
56,0

62,0
63,0
63,0
63,0

74,0
75,0
75,0
75,0

68,5
69,5
69,5
69,5

64,5
65,5
65,5
65,5

62,5
63,5
63,5
63,5

53,0
54,0
54,0
54,0

74,0
75,0
75,0
75,0

Note: Average sound pressure level rated in accordance to ISO 3744, free field conditions.

Physical data WHZ 024.2047.2 (HFC 407C)


WHZ unit size
Cooling capacity (1)
Power input (1)
Compressors number
Compressor model
Reduction steps number
Refrigerant circuits number
Evaporators number
Maximum evaporator water pressure
Ev. Victaulic water connections diam.
Condenser N/passes N
Maximum condenser water pressure
2 passes cond. water connections
Unit length (2 passes)
Unit widht
Unit height
Shipping weight
Operating weight

024.2
kW
kW

bar

84,6
22,1
2
Scroll
2
2
1
16
88,9
2/2
16

mm
mm
mm
kg
kg

1838
600
1555
515
560

bar

032.2

041.2

108,9
142,5
28,2
37,5
2 tandem
2 tandem
Scroll
Scroll
4
4
2
2
1
1
16
16
88,9
88,9
2/2
2/2
16
16
Female 2 GAS
2715
2715
600
600
1555
1555
860
860
900
900

047.2
165,7
45,6
2 tandem
Scroll
4
2
1
16
88,9
2/2
16
2715
600
1555
860
900

Note: (1) Nominal cooling capacity are based on: 12/7C entering/leaving evaporator water temperature; 30/35C entering/leaving
condenser water temperature.

Electrical data
WHZ unit size
Standard voltage supply
Max. #1 comp. absorbed current
Max. #2 comp. absorbed current
Max. unit absorbed current
Max. compressor inrush current
Max. unit inrush current
Notes: Unbalance between phase

602 B 04/11 C pag. 4/8

024.2
A
A
A
A
A

35
35
70
175
210

3% ; allowable voltage tolerance 10%.

032.2

041.2

400 V 3f 50 Hz (1)
50
70
50
70
100
140
120
175
195
280

047.2
70
70
140
175
280

Standard ratings WHZ 024.2 047.2 (HFC 407C)


Unit
size

024.2

032.2

041.2

047.2

Evap.
leaving
water
temp.
(C)

C.C.
(kW)

P.I.
(kW)

C.C.
(kW)

P.I.
(kW)

C.C.
(kW)

P.I.
(kW)

C.C.
(kW)

P.I.
(kW)

C.C.
(kW)

P.I.
(kW)

4
5
6
7
8
9
10
11
12
13
14
15
16
4
5
6
7
8
9
10
11
12
13
14
15
16
4
5
6
7
8
9
10
11
12
13
14
15
16
4
5
6
7
8
9
10
11
12
13
14
15
16

80,8
83,3
85,8
88,4
91,0
93,6
96,3
99,0
101,7
104,4
107,2
110,1
112,9
103,9
107,1
110,3
113,6
117,0
120,4
123,8
127,3
130,9
134,4
138,1
141,6
145,3
135,7
139,9
144,1
148,5
152,9
157,4
161,9
166,5
171,1
175,8
180,6
185,4
190,2
158,3
163,1
168,0
173,0
178,1
183,1
188,4
193,6
198,9
204,3
209,8
215,2
220,8

19,6
19,7
19,8
19,9
20,1
20,2
20,3
20,4
20,6
20,7
20,8
21,0
21,1
24,9
25,0
25,1
25,3
25,4
25,5
25,6
25,8
25,9
26,1
26,3
26,4
26,5
33,3
33,5
33,7
33,9
34,1
34,3
34,5
34,7
34,9
35,1
35,3
35,5
35,8
40,2
40,5
40,7
40,9
41,2
41,4
41,7
42,0
42,3
42,6
42,8
43,1
43,4

77,3
79,7
82,1
84,6
87,1
89,7
92,3
94,9
97,5
100,2
102,8
105,6
108,3
99,5
102,6
105,7
108,9
112,2
115,5
118,8
122,2
125,6
129,1
132,6
136,1
139,7
130,1
134,2
138,3
142,5
146,8
151,2
155,5
160,0
164,5
169,0
173,6
187,3
183,0
151,5
156,2
161,0
165,7
170,7
175,6
180,6
185,7
190,8
196,0
201,3
206,6
212,0

21,7
21,8
22,0
22,1
22,3
22,4
22,5
22,7
22,8
23,0
23,1
23,3
23,4
27,8
28,0
28,1
28,2
28,4
28,5
28,7
28,8
29,0
29,1
29,3
29,4
29,6
36,9
37,1
37,4
37,5
37,8
38,0
38,2
38,4
38,7
38,9
39,1
39,3
39,6
44,7
45,0
45,4
45,6
45,9
46,2
46,4
46,7
47,0
47,4
47,7
48,0
48,3

73,5
75,8
78,2
80,5
83,0
85,4
87,9
90,4
92,9
95,5
98,1
100,8
103,3
94,6
97,6
100,6
103,7
106,9
110,0
113,3
116,5
119,8
123,2
126,5
130,0
133,4
124,1
128,0
132,0
136,0
140,1
144,3
148,5
152,9
157,2
161,6
166,0
170,5
175,0
144,2
148,7
153,2
157,9
162,6
167,4
172,2
177,1
182,0
187,1
192,1
197,2
202,4

24,2
24,4
24,5
24,7
24,8
25,0
25,2
25,3
25,5
25,6
25,8
26,0
26,1
31,2
31,4
31,5
31,7
31,8
32,0
32,2
32,3
32,5
32,6
32,8
33,0
33,1
41,0
41,2
41,4
41,7
41,9
42,1
42,4
42,6
42,8
43,1
43,3
43,6
43,8
49,9
50,2
50,5
50,9
51,2
51,5
51,8
52,1
52,5
52,8
53,1
53,4
53,7

69,4
71,6
73,8
76,1
78,4
80,7
83,1
85,5
88,0
90,4
92,9
95,4
98,0
89,2
92,1
95,0
98,0
101,0
104,0
107,1
110,2
113,4
116,6
119,9
123,1
126,5
117,5
121,3
125,1
129,0
132,9
136,9
140,9
145,0
149,2
153,4
157,7
162,0
166,4
136,1
140,5
144,8
149,3
153,8
158,4
162,9
167,7
172,4
177,2
182,0
187,0
191,9

27,0
27,1
27,3
27,5
27,6
27,8
28,1
28,2
28,4
28,6
28,8
29,0
29,1
35,0
35,2
35,5
35,6
35,8
36,0
36,1
36,3
36,5
36,7
36,9
37,0
37,2
45,5
45,7
46,0
46,2
46,5
46,7
47,0
47,2
47,5
47,7
48,0
48,4
48,6
55,7
56,1
56,4
56,7
57,0
57,3
57,7
58,1
58,5
58,8
59,1
59,6
59,9

64,9
67,0
69,1
71,3
73,5
75,7
77,9
80,2
82,5
84,9
87,3
89,7
92,1
83,2
86,0
88,8
91,6
94,5
97,4
100,3
103,3
106,4
109,4
112,5
115,7
118,8
110,3
113,9
117,6
121,2
125,0
128,8
132,6
136,6
140,5
144,5
148,6
152,8
157,0
127,5
131,6
135,7
139,9
144,2
148,6
152,9
157,4
161,9
166,4
171,1
175,7
180,5

30,2
30,3
30,5
30,7
30,9
31,0
31,2
31,4
31,6
31,8
32,0
32,3
32,5
39,5
39,7
39,8
40,0
40,3
40,5
40,7
40,9
41,1
41,2
41,4
41,6
41,8
50,5
50,7
51,0
51,3
51,5
51,8
52,1
52,3
52,7
53,0
53,3
53,5
53,8
62,2
62,5
62,9
63,3
63,7
64,0
64,4
64,7
65,2
65,6
65,9
66,3
66,8

CONDENSER ENTERING WATER TEMPERATURE - C


25

30

35

40

45

Note: ratings are based on evaporator and condenser fouling factor of 0.044 (m2C/kW) and evaporator and condenser temperature T
of 5C.

602 B 04/11 C pag. 5/8

evaporator

Pressure drop (kPa)

Water pressure drop

Water flow rate (l/s)

Water pressure drop

Pressure drop (kPa)

2 passes condenser

Water flow rate (l/s)


602 B 04/11 C pag. 6/8

WHZ 024.2 dimensions

WHZ
unit size

Dimensions (mm)
B

024.2

A
1838

600

1555

032.2

2715

600

1555

041.2

2715

600

1555

047.2

2715

600

1555

WHZ 032.2047.2 dimensions

602 B 04/11 C pag. 7/8

We reserve the right to make changes in design and construction at any time without notice, thus the cover picture is not binding.

McQuay partecipa al programma di


Certificazione Eurovent.
I prodotti interessati figurano nella Guida
Eurovent dei Prodotti Certificati.

McQuay is participating in the Eurovent


Certification Programme
Product are as listed in the Eurovent
Directory of Certified Products

McQuay Italia S.P.A.


S.S. Nettunense, km 12+300 00040 Cecchina (Roma) Italia Tel. (06) 937311 Fax (06) 9374014 E-mail: info@mcquayeurope.com
www.mcquayeurope.com

602 B 04/11 C pag. 8/8

You might also like