INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
1 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Revision History
Rev.
Date
Prepared
Description
2008-10-27
XCSVIVO
Firm Revision
2008-11-07
XCSVIVO
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
2 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Rev.
Date
Prepared
Description
2009-02-23
XCSGASA
2009-03-10
XCSGASA
2009-05-20
XCSGASA
2009-06-03
EALOFAL
2009-09-15
XCSVIVO
2009-09-30
XCSVIVO
2009-12-14
XCSGASA
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
3 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Rev.
Date
Prepared
Description
2010-01-12
XCSNIKU
Contents
This section will contain the contents (Sections and sub-sections) of the
update document.
HealthCheck
FCR
Executing swrprod
Convention
Commands are always in boldface, font used is Courier New, and written on a
new line. Command printout is in italics and the font is Courier New.
Application
This document shall be used for update of customer sites as well as system
test sites.
Prerequisites
4.1
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
4 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
APG level: Ref [1] 2/1551-5/LZY 242 060/21 Uen Software Record APG40
one track AP1 AGM018 for APG40 with C/2 LBB and Ref [2] 2/1551-5/LZY
242 060/41 Uen Software Record APG40 one track AP1 AGM018 for APG40
with C/4 LBB.
Update time:
The complete installation including FCR upgrade with 15 minutes supervision
period and without burbackup will take approximately 193 minutes for C/2 and
156 minutes for C/4 machines.
4.2
Update Package
The AGM019 package size is 450 MB.
The C:\temp, and F:\temp are used during the update and these must exist.
The free disk space needed during the installation is 600 MB on C and F
drives and 800 MB on G drive. The package should be stored on G:\Ftpvol.
G:\ftpvol, F:\TEMP and C:\TEMP should be empty before the start of the
Installation procedure.
Necessary package fetched from GASK archive as PKZIP (WINZIP) format
019/19099-5/LZY242060 Revision E. The name of the update installation
package file may vary depending on which tool is used when fetching it from
GASK. In this document named as 019_19099-5_LZY242060_E.zip.
Package information can be found in Ref [3] 1551-5/LZY 242 060/1 Uen
Reference Package for APG40 one track AP1 AGM019 for both C/2 and C/4
LBB.
4.3
Tapes get ejected at C/2 sites when loading package. CNI 10922APZ212 30/4-1076, which installs the tape firmware version L411 on
APG40 C/2 systems, will eject any medium present in the tape drive.
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
5 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
AGM019 ACL are not according to design rule. By the way, there are
no drawbacks for customer application. Refer TR HK28561 for details.
4.4
A P4.1 installation failure has been verified when the green LED on tape
drive was always OFF and the amber LED was always ON (none of them
were flashing).
The amber LED Light indicates a "Media Caution" signaled for this DAT
drive prior to the upgrade, in details it means:
Flash Amber: Cartridge is near the end of its life or the heads need
cleaning.
Steady Amber: Hard fault
The drive monitors the number of correctable errors that occur during
reading and writing.
If the number of errors grows excessively, it can mean that the tape is
nearing the end of its useful life, or that the tape heads need cleaning.
The Media Caution signal is cleared when a new tape is loaded or when
the drive is power-cycled
4.5
Health Check
Before starting the update run the latest revision of ALAN tool and correct
the faults as indicated. Run the ALAN after update and compare the
analysis results.
Before starting the update execute the following command to check that
the account password doesnot expires during the update
C:\>dsquery computer -stalepwd 25
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
6 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
4.6
4.6.1
Included CNIs
Name
Package
Rev
R-State
CNI-no
APZ212 XX/X
LBB
R1BS
30/4-1216
LBB
R1BX
30/4-1026
LBB
R1AF
30/4-1076
LBB
R1AF
30/4-1076
LBB
R1BN
30/4-1233
LBB
R1BM
30/4-1217
LBB
R1BU
30/4-1259
LBB
R1BY
30/4-1278
LBB
R1CD
30/4-1305
LBB
R1CF
30/4-1341
ACSBIN
CXC1371068/5
R9B
30/4-1354
AEHBIN
CXC137 90/4
R5B
30/4-1272
AFPBIN
CXC137 1083/5
R2H
30/4-1337
ALOGBIN
CXC1371092/5
R3A
30/4-1114
ASECBIN
CXC1371016/4
R5B
30/4-1287
AVIRBIN
CXC1371268/4
R1A
30/4-1240
BURBIN
CXC1371062/5
AS
R6C
30/4-1299
BURREMRECBIN CXC1371103/5
R3A
30/4-1280
CXC1371084/5
R6B
30/4-1345
CDHBIN
Ericssonwide Internal
7 (80)
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
CHBBIN
CXC137433/4
R7S
30/4-1232
EMFBIN
CXC1371111/5
B2
R2C
30/4-1230
FCHBIN
CXC1371136/5
B2
R3A
30/4-1156
FCRBIN
CXC1371117/5
R2C
30/4-1310
FTPCLIBIN
CXC1371095/5
R2D
30/4-1346
IPNAADMBIN
CXC 1371259/5
R1B
30/4-1205
LCTBIN
CXC1371063/5
R4A
30/4-1344
LOGMBIN
CXC1371079/4
R2D
30/4-1301
NETCFGBIN
CXC1371125/5
R1E
30/4-1356
NSFBIN
CXC 1371091/5
L2
R6B
30/4-1358
PRCBIN
CXC1371059/4
AC2
R8A
30/4-1271
RTRBIN
CXC1371096/5
R4J
30/4-1145
SSUBIN
CXC1371104/5
R3A
10/4-1262
SWRBIN
CXC 1371064/5
D4
R4A
30/4-1226
TOCAPBIN
CXC137611/5
R1C
30/4-1304
TRAINIBIN
CXC13789/4
R1B
30/4-1253
USABIN
CXC1371081/5
R7B
30/4-1353
AISAPIBIN
CXC137425
R3E
30/4-1315
ALECADMBIN
CXC137479/4
R1M
30/4-1222
CPHWBIN
CXC1371010/4
R5B
40/2-178
MCCBIN
CXC137429/4
R4N
30/4-1331
MLSMMLBIN
CXC137430/4
BE
R4AN
30/4-1340
MLSMTSBIN
CXC137474/4
BH
R4J
30/4-1329
MMLAPIBIN
CXC137418/4
R5C
30/4-1306
STSCBIN
R1G
30/4-1313
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
8 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
STSCOUNT01
R1H
30/4-1317
STSCOUNT02
R1G
30/4-1318
STSCOUNT03
R1G
30/4-1319
STSCOUNT04
R1K
30/4-1320
STSCOUNTERS
CXC1371179/5
R1K
30/4-1316
4.6.2
Included files
Note: The folder F:\TEMP shall contain files
apg40_inf_restore.bat
AVIRPATH_check_on_C.vbs
avirbin_Path_Update_on_D.vbs
avirbin_fix.bat
avirbin_reg.reg
busrv.vbs
ChangeTZ.exe
create_dir.vbs
cxc1371268.par
exteldec.bat
extelinc.bat
extelval.bat
fcr.vbs
fcr_delete_user.vbs
F-Secure-Infinite-Idle.vbs
preFCR.exe
restore_hostkey.bat
save_hostkey.bat
save_system_settings.bat
start_stop_cps.bat
swrprod_agm019_AP1.bat
swrprod_agm019_AP2_AP3.bat
telinc.reg
Note: The folder F:\TEMP\Script_1289 shall contain files
100_19089_CXC1371091_5.vbs
install.bat
Note: The folder F:\TEMP\CPS shall contain files
common_Buap.reg
common_Busrv.reg
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
9 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
10 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
"016"
"017"
"018"
"019"
10
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
11 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
:IAM101
swrprod | findstr IAM | find "020"
goto IAM11%ERRORLEVEL%
:IAM110
swrprod -r "IAM" "020" " "
goto END8
:IAM111
swrprod | findstr IAM | find "021"
goto IAM12%ERRORLEVEL%
:IAM120
swrprod -r "IAM" "021" " "
goto END8
:IAM121
swrprod -r "IAM" " " " "
goto END8
:IAM1
goto END11
:END8
swrprod -n "IAM" " " " "
:END9
echo Update system identity
swrsid -n "APG40 One Track AGM019 AP1"
IF ERRORLEVEL 1 GOTO END5
echo "Done!"
GOTO END
:END00
echo Error!!! The swrprod for AGM is either incorrect or
not present
echo Please check with the earlier version of software
print
GOTO END
:END1
echo Error!!! The swrprod for APM is either incorrect or
not present
echo cannot remove the software product identification
for APM.
echo Please check with the earlier version of software
print
GOTO END
:END2
echo Error!!! The swrprod for APIO is either incorrect or
not present
echo cannot remove the software product identification
for APIO.
echo Please check with the earlier version of software
print
GOTO END
:END4
echo Error!!! The swrprod command for adding AGM identity
failed
GOTO END
:END5
11
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
12 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Installation Procedure
NOTE: The logon of a node shall be performed as a user, remotely by using
telnet or Winfiol .This user can be administrator. It can also be another user
that belongs to the groups Administrators & Domain Admins .
Check using following commands whether the user being used to do the
update belongs to the group Domain Admins
F:\TEMP>net group Domain Admins
If the user is not a member of the groups mentioned above, run the following
commands to add user to the groups
Note:For this logon should be done as administrator
F:\TEMP>net group "Domain Admins" <user name> /add
5.1
12
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
5.2
13 (80)
Reference
Active node
Perform a failover.This step could avoid a possible soft function change failure
due to long time needed to set cluster resources off line.
Log on and verify that the node is active.
C:\>prcstate
RESULT:
Active
Perform a failover
C:\>prcboot f
RESULT:
REBOOT INITIATED!....
Wait approximately 7 minutes from the time of reboot.
Active node
Log on to (new) active node after the reboot and verify that the node has
started in passive mode.
C:\>prcstate
RESULT:
Active
Disable the automatic backup.
F:\Temp>sfcstate
RESULT:
13
Ericssonwide Internal
14 (80)
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
CXCNUMBER
MODULENAME
REVISION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
CXC1371062
CXC1371065
CXC1371096
CXC1371147
CXC137440
CXC1371084
CXC1371087
CXC1371088
CXC1371094
CXC1371097
CXC1371100
CXC1371057
CXC1371002
CXC1371004
CXC1371077
CXC137418
CXC137425
CXC137429
CXC137430
CXC137431
CXC137471
CXC137474
CXC137479
CXC1371102
CXC1371140
CXC1371243
BURBIN
AVIRBIN
RTRBIN
APCONFBIN
ACABIN
CDHBIN
DBOBIN
GCCBIN
SSHSERVBIN
CPFADMBIN
FCCAPIBIN
CPTASPBIN
ALDABIN
ALISADMBIN
MLSMSSBIN
MMLAPIBIN
AISAPIBIN
MCCBIN
MLSMMLBIN
PDSPGMBIN
ADHADMBIN
MLSMTSBIN
ALECADMBIN
CLHADMBIN
SGSBIN
STSCBIN
R6A
R5A
R4H
R1D
R6D
R5A
R1D
R1C
R1F
R1J
R1C
R5C
R1E
R2E
R2C
R5B
R3D
R4M
R4AL
R4D
R3H
R4F
R1L
R2D
R1D
R1E
CNI
APZ21230/4-1084
APZ21230/4-1165
APZ21230/4-1082
APZ21230/4-1153
APZ21230/4-1174
APZ21230/4-1202
APZ21230/4-1151
APZ21230/5-485
APZ21230/4-1000
APZ21230/4-836
APZ21230/4-990
APZ21230/6-912
APZ21230/6-897
APZ21230/4-807
APZ21230/4-1179
APZ21230/4-1007
APZ21230/4-1101
APZ21230/4-1178
APZ21230/4-1123
APZ21230/4-1013
APZ21240/3-172
APZ21230/4-1100
APZ21230/4-1144
14
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
15 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
ACS_BUR_system_bkp_freq
Edit the parameters for ACS_BUR_archive_backup and
ACS_BUR_system_backup to 0 to disable the automatic
backup.
:edit ACS_BUR_archive_backup
Category: Private
unsignedShortInt[0, 1] (1):0
:edit ACS_BUR_system_backup
Category: Private
unsignedShortInt[0, 1] (0):0
:end
Parameters updated
Exiting ...
Would you like to edit more parameter files?
[y(es)/n(o)]:n
System upgrade performed. Would you like to switch to the
new system,
thereby starting the supervision period? (No will abort
and restore
the system. [y(es)/n(o)]:y
Parameter tables generated. No errors found.
Change of parameter(s) succeeded, supervision period has
started.
Execute sfcend when supervision period is over.
F:\temp>sfcstate
Soft function change is in state 'Supervision'.
F:\temp>sfcend
Soft function change session has ended.
5.3
Active node
Extract the update package file to the temp directory on G:\ drive.
F:\temp>pkzipc -extract -dir
-over=all \\clustername\G$\ftpvol\019_190995_LZY242060_E.zip G:\temp
RESULT:
15
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
16 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Version 6.0
FAST!
Prompt is returned
Delete the G:\temp folder
F:\temp>rd /S /Q G:\TEMP
16
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
17 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
RESULT:
Prompt is returned
5.4
Both nodes
This .bat file saves the SSH, Telnet and apg40.inf settings
F:\TEMP>save_system_settings.bat
RESULT:
1
1
1
1
file(s)
file(s)
file(s)
file(s)
copied.
copied.
copied.
copied
5.5
Both nodes
Update with SSH application
Note: This step should only be done if connecting to the AP using SSH
protocol.
Install configuration file with extended idle timeout:
17
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
18 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
F:\TEMP>F-Secure-Infinite-Idle.vbs
RESULT:
5.6
Both nodes
NOTE: Please note the firmware versions (RAID-FW, AM-FW and CPU BIOS)
before starting the update procedure. These values are required to decide on
actions during a fallback, in case.
Check the hardware version
C:\>hwver
RESULT:
AP HARDWARE VERSION
APG40C/4 or APG40C/2
Print the RAID FW version for C/2
C:\>raidutil K
RESULT:
Address
Manufacturer/Model
FW
Cluster Suppor
----------------------------------------------d0
DPT
PM3757U2
FT0A Enabled
18
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
19 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
*********************************************************
*************
MEGARC MegaRAID Configuration Utility(NT)1.14_Wrap1.0.3(2-17-2006)
By LSI Logic Corp.,USA
*********************************************************
*************
[Note: For SATA-2, 4 and 6 channel controllers, please
specify
Ch=0 Id=0..15 for specifying physical drive(Ch=channel,
Id=Target)]
Type ? as command line arg for help
*********************************************************
*************
Information of Adapter-0 (#Adapter(s) on system: 1)
*********************************************************
*************
Firmware Version : 414#
BIOS Version : H429
Logical Drives : 03
DRAM : 128MB
Rebuild Rate : 50%
Flush Interval : 4 secs
Number Of Chnls : 2
Bios Status :
Disabled
Alarm State : Disabled
Auto Rebuild :
Enabled
FW : SPAN-8, 40-LD
BIOS Config
AutoSelection : DISK
BIOS Echos Mesg : ON
BIOS Stops On
Error : OFF
Initiator Id : 7(Clustered Firmware)
Board SN:
*********************************************************
*************
Exiting with 0
Print the AM version
C:\>fcc_amversion own
RESULT:
1.13
Print the CPU BIOS version (only on C/4)
C:\>wmic bios list BRIEF
19
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
20 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
RESULT:
Manufacturer Name SerialNumber SMBIOSBIOSVersion Version
Phoenix Technologies LTD Phoenix NoteBIOS 4.0 Release 6.0
Not Applicable 2.0.5B PTLTD - 6040000
5.7
Active node
C:\>mtzln p
RESULT:
TMZ : TZ
-----------------------------------0 = (GMT+01:00) Amsterdam, Berlin, Bern, Rome,
Stockholm, Vienna
Executed
Note: This is an example printout.
Note the output of the above command as it will be required in the fallback
procedure
5.8
5.8.1
Both Nodes
Verify in the following way that the replication is without errors
C:\>cd C:\Program files\Force\frconfig\domainrename
RESULT:
C:\Program files\Force\frconfig\domainrename>
C:\Program files\Force\frconfig\domainrename>repadmin
howrepl
/s
RESULT:
repadmin running command /showrepl against server
localhost
Default-First-Site-Name\AP10B
DC Options: (none)
Site Options: (none)
DC object GUID: e319fc1a-cbca-4444-b9bc-a7a1eb2a5737
DC invocationID: 954ea6e9-5120-47ed-8dbb-eb25ab1c1303
==== INBOUND NEIGHBORS=============================
DC=ap10dom,DC=int
Default-First-Site-Name\AP10A via RPC
20
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
21 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
21
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
22 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
829483a2b432._msdcs.ap212dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors
This doesn't solve any replication problems. It only facilitates
replication to happen at that moment (without waiting for the scheduled
replication) provided there are no replication problems, and thus avoids
situations like the user being found in one node and not found in the
other. Basically it will synchronize the active directory details
instantaneously. If a machine is not able to replicate this means that
there is some fault with the machine (probably caused due to a bad
restore or due to some other reason).
If there is no replication between the nodes before the installation
starts, the installation may fail. If there is a problem with replication contact
the next level of support.
5.8.2
File Replication
C:\Program files\Force\frconfig\domainrename>f:
F:\>Cd Temp
Verify in the following way that the File replication is without errors.
Create two files to test File Replication:
NodeA
F:\TEMP>copy
nul \\192.168.202.1\c$\winnt\sysvol\domain\scripts\testa.
txt
RESULT:
1 file(s) copied.
NodeB
F:\TEMP>copy
nul \\192.168.202.2\c$\winnt\sysvol\domain\scripts\testb.
txt
RESULT:
1 file(s) copied.
Verify if BOTH created files are present in BOTH nodes:
NodeA
F:\TEMP>dir \\192.168.202.1\c$\winnt\sysvol\domain\script
s\
RESULT:
Volume in drive \\192.168.202.1\c$ is ntserv
Volume Serial Number is 8045-1876
Directory
of \\192.168.202.1\c$\winnt\sysvol\domain\scripts
04/10/2008 02:20 PM
<DIR>
.
04/10/2008 02:20 PM
<DIR>
..
22
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
23 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
04/25/2002 01:53 PM
acs_acsc_warning.bat
04/10/2008 02:20 PM
04/10/2008 02:20 PM
3 File(s)
2 Dir(s)
Reference
114
0 testa.txt
0 testb.txt
114 bytes
1,362,063,360 bytes free
NodeB
F:\TEMP>dir \\192.168.202.2\c$\winnt\sysvol\domain\script
s\
RESULT:
Volume in drive \\192.168.202.2\c$ is ntserv
Volume Serial Number is 8045-1876
Directory
of \\192.168.202.2\c$\winnt\sysvol\domain\scripts
04/10/2008 02:20 PM
<DIR>
.
04/10/2008 02:20 PM
<DIR>
..
04/25/2002 01:53 PM
114
acs_acsc_warning.bat
04/10/2008 02:20 PM
0 testa.txt
04/10/2008 02:20 PM
0 testb.txt
3 File(s)
114 bytes
2 Dir(s)
1,362,063,360 bytes free
Remove the test files:
NodeA
F:\TEMP>del \\192.168.202.1\c$\winnt\sysvol\domain\script
s\testa.txt
RESULT:
Prompt is returned
NodeB
F:\TEMP>del \\192.168.202.2\c$\winnt\sysvol\domain\script
s\testb.txt
RESULT:
Prompt is returned
Verify if both the files are deleted in both nodes:
NodeA
F:\TEMP>dir \\192.168.202.1\c$\winnt\sysvol\domain\script
s\
RESULT:
Volume in drive \\192.168.202.1\c$ is ntserv
Volume Serial Number is F005-D27B
Directory
of \\192.168.202.1\c$\winnt\sysvol\domain\scripts
04/10/2008 07:28 PM
<DIR>
.
23
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
24 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
04/10/2008 07:28 PM
<DIR>
..
04/10/2008 12:57 PM
114
acs_acsc_warning.bat
1 File(s)
114 bytes
2 Dir(s)
1,115,570,176 bytes free
NodeB
F:\TEMP>dir \\192.168.202.2\c$\winnt\sysvol\domain\script
s\
RESULT:
Volume in drive \\192.168.202.2\c$ is ntserv
Volume Serial Number is 8045-1876
Directory
of \\192.168.202.2\c$\winnt\sysvol\domain\scripts
04/10/2008 02:21 PM
<DIR>
.
04/10/2008 02:21 PM
<DIR>
..
04/25/2002 01:53 PM
114
acs_acsc_warning.bat
1 File(s)
114 bytes
2 Dir(s)
1,362,063,360 bytes free
Note: If there is no replication between the nodes before the installation
starts, the installation may fail. If there is a problem with replication contact
the next level of support.
5.9
Update Procedure
NOTE: DO NOT use GUI during the installation.
A-node
1. Logon to node A.
Verify that the cluster group is up and running and node is passive
F:\TEMP>cluster group
RESULT:
Group
Node
Disk Group
APXXB
RGAPM_1
APXXB
Online
Cluster Group
APXXB
Online
RGAPM_0
APXXA
Online
APXXB
Online(on C/2)
PMC860 Group
Status
Online
24
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
25 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
F:\TEMP>prcstate
RESULT:
Passive
or
Active
If the result is passive, continue with step 4. If node A is active, continue with
step 2.
2. Perform a failover from node A to node B.
C:\>prcboot f
RESULT:
REBOOT INITIATED!....
Wait approximately 7 minutes from the time of reboot.
3. Log on to node A after the reboot and verify that the node has started in
passive mode.
C:\>prcstate
RESULT:
Passive
Verify that all cluster resources are online
C:\>cluster group
RESULT:
Group
Node
Disk Group
APXX
B
RGAPM_1
APXXB
Online
Cluster Group
APXXB
Online
RGAPM_0
APXXA
Online
APXXB
Online(on C/2)
PMC860 Group
Status
Online
25
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
26 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Both Nodes
4. Workaround for TR HJ56640- copy SSH hostkey to f:\temp.
F:\TEMP>save_hostkey.bat
RESULT:
1 file(s) copied.
1 file(s) copied.
Verify the execution of the command
F:\temp>echo %errorlevel%
The result should be 0.
Workaround for R35 Patch(CSR 1272722)
F:\TEMP>cd R35Patch
F:\TEMP\R35Patch>R35PatchForAGM019.bat
5. Save the ApSwFileAcl.da2 from the fcr package
F:\temp>copy
\\<clustername>\G$\fcr_upgrade\config\ApswFileAcl.da2
F:\temp
RESULT:
1 file(s) copied.
F:\temp>apaclset -b f:\temp\ApSwFileAcl.da2 -v f >
F:\temp\acl.txt q
RESULT:
Prompt is returned
6. Add the missing users
F:\temp>fcr.vbs
RESULT:
26
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
27 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
ACS_FCR_Server
RESULT2:
AP35B:
Parameter file for backup does not exist:
K:\APZ\DATA\BOOT
Save all disk information and runtime parameter data to
file \\AP35A\C$\acs\data\BUR\AP35A_20081217_050813.ddi
completed
Parameter file for backup does not exist:
K:\APZ\DATA\BOOT
Save all disk information and runtime parameter data to
file \\AP35B\C$\acs\data\BUR\AP35B_20081217_050813.ddi
completed
Continuing with partition backup please wait
AP35A:
burBackup partition backup completed
1769 directories and 17914 files copied or equal and 0
files locked
AP35B:
burBackup partition backup completed
1831 directories and 17955 files copied or equal and 0
files locked
burBackup one button backup execution completed
Both Nodes
27
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
28 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
28
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
29 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
29
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
30 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
30
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
31 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
31
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
32 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
32
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
33 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
33
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
34 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
/off /wait
F:\temp>nsfstop
RESULT:
Started or Starting
If the state is started goto step 18. If the state is starting even after 30 minutes
continue with step 14.
14. Check the hostname
C:\>hostname
34
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
35 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
RESULT:
APXXA
15. Disable and enable the replication for this host. Use hostname checked at the
previous step
C:\>cd /d "C:\program files\force\frconfig\domainrename"
C:\program files\force\frconfig\domainrename>repadmin
/options <hostname> +DISABLE_INBOUND_REPL +
DISABLE_OUTBOUND_REPL
C:\ program files\force\frconfig\domainrename>repadmin
/options <hostname> -DISABLE_INBOUND_REPL
-DISABLE_OUTBOUND_REPL
RESULT:
Current DC Options: IS_GC DISABLE_INBOUND_REPL
DISABLE_OUTBOUND_REPL
New DC Options: IS_GC
16. Force replication.
C:\program files\force\frconfig\domainrename>repadmin
/syncall /A <A-node hostname>
RESULT:
Syncing all NC's held on AP33A.
Syncing partition: DC=ForestDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=DomainDnsZones,DC=ap33dom,DC=int
35
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
36 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
36
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
37 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Note: This is an example printout
C:\program files\force\frconfig\domainrename>repadmin
/syncall /A <B-node hostname>
RESULT:
Syncing all NC's held on AP33B.
Syncing partition: DC=DomainDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=ForestDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
37
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
38 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
38
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
39 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Started
If the state is not started then wait for some time and again repeat step 17 till
state Started is reached. Even then if state Started is not reached after 40
min (since the time of reboot), then a FCR restore is required. Follow OPI for
Ref [5] AP, Function Change Reference Package, Manual Restore
18. Print the cluster group.
C:\>cluster group
RESULT:
Group
Node
Disk Group
APXXB
RGAPM_1
APXXB
Online
Cluster
Group
APXXB
Online
RGAPM_0
APXXA
Offline
APXXB
PMC860
Group
an example printout.
Status
Partially Online
This
is just
19. Execute the bat file to resolve the issues for msi popup and GMT (TR
HK22550)
F:\Temp>avirbin_fix.bat
Note: Check for the string Error Level: -5 in the result printout.
If error level is -5, then the installation is success, if any other error level the
installation has failed.
RESULT:
39
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
40 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
1/25/2009 3:30:18 PM
for node AP33A...
1/25/2009 3:30:18 PM
AP33A are:2
1/25/2009 3:30:18 PM
for node AP33B...
1/25/2009 3:30:19 PM
AP33B are:4
1/25/2009 3:30:19 PM
1/25/2009 3:30:19 PM
1/25/2009 3:30:19 PM
1/25/2009 3:30:19 PM
execution: START...
>
>
>
>
>
>
>
>
INFO
INFO
INFO
INFO
Reference
3:30:19 PM >
Activating
Note : Check for the state at intervals of 3 min. until the state becomes
Activated
22. Check the fcrstate again
C:\>fcrstate
RESULT:
Activated
Note: If the state is activated then continue with step 23 else wait for some
time and then repeat the step. Even then the state Activated is not reached
after 40 min, then a FCR restore is required. Follow OPI for Ref [5] AP,
Function Change Reference Package, Manual Restore
Non-updated passive node-B
40
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
41 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Passive
Verify that all cluster resources are online
F:\TEMP>cluster group
RESULT:
Group
Node
Disk Group
APXXA
RGAPM_1
APXXB
Online
Cluster
Group
APXXA
Online
RGAPM_0
APXXA
Online
APXXA
Online (Only on
C/2)
PMC860
Group
Status
Partially
Online
Are you sure that you want to execute command fcrcontinue '?
[y(es)/n(o)]:yes
Answer with yes to continue fcr session.
The procedure installs all CXCs including anti-virus on the node. The
installation takes approximately 10 minutes. After the installation a reboot is
initiated.
Note:Wait for 5 min after reboot to login.
Passive B Node
41
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
42 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Continued or Continuing
If the state is continued goto step 30. If the state is continuing even after 30
minutes continue with step 26.
26. Check the hostname
C:\>hostname
RESULT:
APXXB
27. Disable and enable the replication for this host. Use hostname checked at the
previous step
C:\>cd /d "C:\program files\force\frconfig\domainrename"
C:\program files\force\frconfig\domainrename>repadmin
/options <hostname> +DISABLE_INBOUND_REPL +
DISABLE_OUTBOUND_REPL
C:\ program files\force\frconfig\domainrename>repadmin
/options <hostname> -DISABLE_INBOUND_REPL
-DISABLE_OUTBOUND_REPL
RESULT:
Current DC Options: IS_GC DISABLE_INBOUND_REPL
DISABLE_OUTBOUND_REPL
New DC Options: IS_GC
28. Force replication.
C:\program files\force\frconfig\domainrename>repadmin
/syncall /A <A-node hostname>
RESULT:
Syncing all NC's held on AP33A.
Syncing partition: DC=ForestDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
42
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
43 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=DomainDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition:
CN=Schema,CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
43
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
44 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
44
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
45 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
45
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
46 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
29. Check the fcrstate .
C:\>fcrstate
RESULT:
Continued
If the state is not Continued then wait for some time and again repeat step
29 till state Continued is reached. Even then if the state is not reached after
40 min then a FCR restore is required. Follow OPI for Ref [5] AP, Function
Change Reference Package, Manual Restore
30. Print the cluster group.
C:\>cluster group
RESULT:
Group
Node
Disk Group
APXXA
RGAPM_1
APXXB
Offline
Cluster
Group
APXXA
Online
RGAPM_0
APXXA
Online
APXXA
PMC860
Group
Status
Partially Online
46
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
47 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
RESULT:
3:30:19 PM >
Are you sure that you want to execute command 'fcrend '?
[y(es)/n(o)]:yes
47
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
48 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
noFCR
34.Put diskeeper resource online
F:\temp>cluster res diskeeper
/on /wait
Group
Node
Disk Group
APXXA
RGAPM_1
APXXB
Online
Cluster
Group
APXXA
Online
RGAPM_0
APXXA
Online
APXXA
PMC860
Group
Status
Online
Both Nodes
36. Delete the dummy user created for fcr
48
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
49 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
F:\temp>fcr_delete_user.vbs
RESULT:
1 file(s) copied.
1 file(s) copied.
Verify the execution of the command
F:\temp>echo %errorlevel%
The result should be 0.
39. Restore the old apg40.inf file
F:\TEMP>apg40_inf_restore.bat
RESULT:
1 file(s) copied.
Verify the execution of the command
F:\temp>echo %errorlevel%
The result should be 0.
40. Restore the inodist.ini file
F:\TEMP>copy F:\temp\inodist.ini C:\acs\data\AVIR /Y
RESULT:
1 file(s) copied
49
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
50 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
1 file(s) copied
F:\TEMP>copy \\clustername\G$\fcr_upgrade\root\acs\data\
FCH\current\CXC1371268\eTrustRestoreProxy.vbs C:\Temp
RESULT:
1 file(s) copied
F:\TEMP>C:\Temp\eTrustRestoreProxy.bat
RESULT:
Prompt is returned
42. Get the date, time & localtimezones simultaneously on both nodes with the
following commands and ensure that the output is same on both nodes before
starting installation.
F:\TEMP>time /t && date /t
F:\TEMP>ChangeTZ c
If the time or date or localtimezones are different on both nodes then
execute step 43 on passive node or continue with step 45 on passive node
Passive node
43. Logon to the node.Verify that the node is passive
F:\TEMP>prcstate
RESULT:
Passive
44. To change the time use the following command (In accordance with active
node)
F:\TEMP>time
To change the date use the following command
F:\TEMP>date
50
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
51 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Passive
F:\TEMP>cluster group
RESULT:
Group
Node
Disk Group
APXXA
RGAPM_1
APXXB
Online
Cluster
Group
APXXA
Online
RGAPM_0
APXXA
Online
APXXA
PMC860
Group
Status
Online
51
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
52 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
52
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
53 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
F:\temp>fchstate -q Schedule
Result:
F:\temp>fchstate -q Schedule
Schedule DISABLED : Stopped
Enable and Start the Schedule Service
F:\temp>sc config Schedule start= Demand
F:\temp>net start Schedule
Result:
F:\temp>net start Schedule
The Schedule service is starting.
The Schedule service was started successfully.
F:\temp>sc config Schedule start= demand
[SC] ChangeServiceConfig SUCCESS
Check the status of the schedule service
F:\temp>fchstate -q Schedule
Result:
F:\temp>fchstate -q Schedule
Schedule DEMAND START : Running
If the schedule service is not started continue with the next command else
goto step 49
F:\temp>shutdown /R /F /T 1
Result:
REBOOT INITIATED!
Wait approximately 5 minutes from the time of reboot.
After the node is up and running start the schedule service
F:\temp>net start Schedule
Result:
F:\temp>net start Schedule
The Schedule service is starting.
The Schedule service was started successfully.
Check the status of the schedule service
53
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
54 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
F:\temp>fchstate -q Schedule
Result:
F:\temp>fchstate -q Schedule
Schedule Manual : Started
49. Stop & Disable the services ACS_PRC_ClusterControl and
ACS_FCH_Server
It must be peformed in the following order:
F:\temp>net stop ACS_PRC_Clustercontrol
F:\temp>sc config ACS_PRC_Clustercontrol start= disabled
F:\temp>net stop ACS_FCH_Server
F:\temp>sc config ACS_FCH_Server start= disabled
This step stops and changes Startup to Disabled for the following
services:
ACS_FCH_Server and ACS_PRC_ClusterControl
Wait for the following printouts (it takes some seconds) for all the services
before continuing with the step 50
RESULT:
F:\temp>fchstate -q ACS_PRC_clustercontrol
54
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
55 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
AP HARDWARE VERSION
APG40C/4 or APG40C/2
If APG40C/2 continue with step 53, otherwise if APG40C/4 goto step 55
53. Installation of R3.11
F:\TEMP>F:\Temp\APG40\LBB\hfx_r311\hfx_r311.bat
Note: The installation will approximately takes 1 minute on C/2
RESULT:
55
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
56 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
56
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
57 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
57
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
58 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
58
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
59 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
REBOOT INITIATED!
Wait approximately 5 minutes from the time of reboot.
63. Verify that the node is the Passive node
F:\TEMP>prcstate
RESULT:
Passive
64. This step has to be performed only if the error level received at step 61 is 0.
If error level received at step 61 is other than 0, the behaviour is specified at
step 61 already
Verify that the security level is S6.2.5.
F:\TEMP>swrprint| findstr /c:"Force Security Patch: 6.2.5"
65. Check the errorlevel
F:\TEMP>echo %errorlevel%
If 0, continue with step 66
If other value than 0, and it is the first time that security level 6.2.5 is
checked then go to step 59
If other value than 0, and it not the first time that security level 6.2.5 is
checked then installation of hfx_e33 failed
59
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
60 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Group
Node
Disk Group
APXXA
RGAPM_1
APXXB
Online
Cluster
Group
APXXA
Online
RGAPM_0
APXXA
Online
APXXA
PMC860
Group
Status
Online
67. Check the contents of the created log files of hfx_p41, hfx_r311, hfx_r310,
hfx_r313, hfx_r318, hfx_r317 and hfx_e33.
F:\TEMP>type F:\Temp\APG40\LBB\hfx_p41\hfx_p41.log
The following line shall be received at the end of the log file.
"hfx_p41 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP>type F:\Temp\APG40\LBB\hfx_r311\hfx_r311.log
Note: Run the above command on only APG40 C/2
The following line shall be received at the end of the log file.
"hfx_r311 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP>type F:\Temp\APG40\LBB\hfx_r310\hfx_r310.log
Note: Run the above command on only APG40 C/2
The following line shall be received at the end of the log file.
"hfx_r310 hotfix successfully applied!"
After the above line checksum information will be displayed
60
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
61 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
F:\TEMP>type F:\Temp\APG40\LBB\hfx_r313\hfx_r313.log
Note: Run the above command on only APG40 C/4
The following line shall be received at the end of the log file.
"hfx_r313 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP>type F:\Temp\APG40\LBB\hfx_r318\hfx_r318.log
The following line shall be received at the end of the log file.
"hfx_r318 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP> type F:\Temp\APG40\LBB\hfx_r317\hfx_r317.log
The following line shall be received at the end of the log file.
"hfx_r317 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP>type F:\Temp\APG40\LBB\hfx_e33\hfx_e33.log
The following lines shall be received at the end of the log file.
INFO -- hfx_e33 Hotfix successfully applied
INFO -- hfx_e33 Please Reboot the machine in order to apply the changes
INFO -- Error Level: 0
68. Remove the LBB folder from F:\Temp in order to get free space on F:\
F:\TEMP>rd /S /Q F:\TEMP\APG40\LBB
RESULT:
Prompt is returned
69. Change the startup type for diskeeper
F:\temp>sc config diskeeper start= Demand
Active node
70. Logon to the node
Verify that the node is Active
F:\TEMP>prcstate
RESULT:
Active
Verify that all cluster resources are online
F:\TEMP>cluster group
RESULT:
61
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
62 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Group
Node
Disk Group
APXXA
RGAPM_1
APXXB
Online
Cluster
Group
APXXA
Online
RGAPM_0
APXXA
Online
APXXA
PMC860
Group
Status
Online
REBOOT INITIATED!
Wait approximately 7 minutes from the time of reboot.
Passive node
72. Logon to the node
Verify that the node is the passive node
F:\TEMP>prcstate
RESULT:
Passive
Verify that all cluster resources are online
F:\TEMP>cluster group
RESULT:
62
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
63 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Group
Node
Disk Group
APXXB
RGAPM_1
APXXB
Online
Cluster
Group
APXXB
Online
RGAPM_0
APXXA
Online
APXXB
PMC860
Group
Status
Online
73. Repeat steps 45 69 on this passive node then continue with step 74
Active Node
74. Logon to the node
Verify that the node is the Active node
F:\TEMP>prcstate
RESULT:
Active
Verify that all cluster resources are online
F:\TEMP>cluster group
RESULT:
63
Ericssonwide Internal
64 (80)
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
75.
Reference
Group
Node
Disk Group
APXXB
RGAPM_1
APXXB
Online
Cluster
Group
APXXB
Online
RGAPM_0
APXXA
Online
APXXB
PMC860
Group
Status
Online
Get
64
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
65 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
F:\TEMP>mtzln -p
This command will list the current timezone association with CP.
Note the association number from the printout.(If the association is already
lost, then note the association number as 0)
If mtzln p reports null or if mtzln p output does not match with
ChangeTZ c from step 75, continue with following steps else proceed with
step 77. (Refer Appendix A in Chapter 7 for different TimeZones).
F:\TEMP>mtzln -r "associationnumber"
Use this command to remove the current assocaition with CP.
In the above command replace the associationnumber with the one noted in t
he above command(without quotes).If the association is found as lost in the
above command, then this command need not be executed .
F:\TEMP>tzls
This command lists the timezones in AP.Note the name
of the local timezone(of AP) from this list
F:\TEMP>mtzln -f "NewTimeZone" "associationnumber"
This comamnd will reassociate the AP localtimezone with CP.
Replace the NewTimeZone and associationnumber with
the ones noted in the above commands(without quotes).
Both Nodes
77. Execute the nsf script to update the registry information for NSFBIN
F:\temp\>cd Script_1289
F:\temp\Script_1289>install.bat
RESULT:
-------------------------------------------------------.
CNI 109 22-APZ 212 30/4-1289
.
09.2008
-------------------------------------------------------Script execution starts to perform adding registry for
CNI-APZ21230/4-1289
Info --- Shell Object created successfully. RESULT CODE
[0]
Info --- Registry successfully read from
HKLM\SYSTEM\CurrentControlSet\Control\Session
Manager\BootExecute RESULT CODE [0]
reg add "HKLM\System\CurrentControlSet\Control\Session
Manager" /v BootExecute /t REG_MULTI_SZ /d "autocheck
autochk /k:GJKLMQRSVY *"\0"autocheck
burStartup"\0"autocheck
C:\WINNT\System32\biostimerecovery.exe" /f
65
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
66 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
AP HARDWARE VERSION
APG40C/4 or APG40C/2
If APG40C/2 goto step 81, otherwise if APG40C/4 goto step 80
80. Enable smart data collection on C/4
F:\temp>c:
C:\>cd Progra~1\force\tools
C:\progra~1\force\tools>frlbbdiag -i
RESULT:
[
[
[
[
[
[
[
[
[
[
[
[
[
[
[
[
[
[
[
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
frlbbdiag.exe 1.0.0.4
Emerson Network Power GmbH
Copyright (C) 2008 Emerson Network Power GmbH
Platform 8.1.4
Frlbbdiag tool running on node AP33A
enabling SMART on d0b0t0d0
-- done.
enabling SMART on d0b0t1d0
-- done.
enabling SMART on d0b0t2d0
-- done.
enabling SMART on d0b1t0d0
-- done.
enabling SMART on d0b1t1d0
-- done.
enabling SMART on d0b1t2d0
-- done.
Ignoring all log data older than 30 day(s)!
Start analyzing physical disk[0] = d0b0t0d0
66
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
67 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
[
[
[
[
[
[
[
[
INFO
INFO
INFO
INFO
INFO
INFO
- - NOTE
NOTE
]
]
]
]
]
]
]
]
Reference
Both nodes
81. Copy the IPNA files in tftpboot folder (HK29160)
F:\temp>copy C:\Program
Files\AP\OCS\Conf\boot.ipnx.not_loading
C:\tftpboot\boot.ipn2 /Y
RESULT:
1 file(s) copied.
F:\temp>copy C:\Program
Files\AP\OCS\Conf\boot.ipnx.not_loading
C:\tftpboot\boot.ipn3 /Y
RESULT:
1 file(s) copied.
82. Execute the step to enable the APBACKUPUSRG to take backup (TR
HK28733)
F:\temp>C:\Program
Files\AP\ACS\BIN\runburserverdcomperm.bat
Result:
Successfully set the Application Launch ACL
83. Confirm the Etrust services are in automatic state and started, use the
following commands
F:\temp>fchstate q InoTask
F:\temp>fchstate -q InoRPC
F:\temp>fchstate -q InoRT
RESULT:
67
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
68 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
If the above services are automatic and running then go to step88 else
continue with step 84.
84. Confirm that the antivirus path is updated.
F:\temp>PATH
RESULT:
68
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
69 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
can have any value for X depending of the number of ControlSet on the
registry of the target system.
86. Start the eTrust Services on the node
F:\temp>sc config InoTask start= Auto
RESULT: [SC] ChangeServiceConfig SUCCESS
69
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
70 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
5.10
Both nodes
Execute the product update installation script
F:\TEMP>swrprod_agm019_AP1.bat
RESULT:
5.11
70
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
71 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
C:>vlanbackup <nodeA>
C:>vlanbackup <nodeB>
where nodename is the name of the node
5.12
Both nodes
Update with SSH application
Note! This step should only be done if connected to AP using SSH protocol.
Save original configuration file on C:\ drive from F:\ drive:
C:\>copy "F:\temp\sshd2_config" "C:\Program Files\FSecure\SSH Server\sshd2_config" /Y
RESULT:
To apply the new settings for idle timeout a new session must be started, log
out and then log in again.
Update with Telnet application
Note! This step should only be done if connected to the AP through Telnet
protocol.
Restore the original timeout value for Pragma Telnet
F:\temp\>exteldec.bat
To apply the new settings for idle timeout a new session must be started, log
out and then log in again.
5.13
Both nodes
Copy the par file in the C:\temp
F:\Temp>xcopy F:\temp\CXC1371268.par C:\temp
RESULT:
1 file(s) copied.
71
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
72 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Active node
Execute Soft function change to enable automatic backup and include Etrust
services in PRC monitoring..
C:\Temp>sfcstate
RESULT:
72
Ericssonwide Internal
73 (80)
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
CXCNUMBER
MODULENAME
REVISION
CNI
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
CXC1371062
CXC1371096
CXC1371147
CXC1371268
CXC137440
CXC1371084
CXC1371087
CXC1371088
CXC1371094
CXC1371097
CXC1371100
CXC1371057
CXC1371002
CXC1371004
CXC1371077
CXC137418
CXC137425
CXC137429
CXC137430
CXC137431
CXC137471
CXC137474
CXC137479
CXC1371102
CXC1371140
CXC1371243
BURBIN
RTRBIN
APCONFBIN
AVIRBIN
ACABIN
CDHBIN
DBOBIN
GCCBIN
SSHSERVBIN
CPFADMBIN
FCCAPIBIN
CPTASPBIN
ALDABIN
ALISADMBIN
MLSMSSBIN
MMLAPIBIN
AISAPIBIN
MCCBIN
MLSMMLBIN
PDSPGMBIN
ADHADMBIN
MLSMTSBIN
ALECADMBIN
CLHADMBIN
SGSBIN
STSCBIN
R6C
R4J
R1D
R1A
R6D
R6B
R1D
R1C
R1F
R1J
R1C
R5C
R1E
R2E
R2C
R5C
R3E
R4N
R4AN
R4D
R3H
R4J
R1M
R2D
R1D
R1G
APZ21230/4-1299
APZ21230/4-1145
APZ21230/4-1165
APZ21230/4-1082
APZ21230/4-1345
APZ21230/4-1153
APZ21230/4-1174
APZ21230/4-1202
APZ21230/4-1151
APZ21230/5-485
APZ21230/4-1000
APZ21230/4-836
APZ21230/4-990
APZ21230/6-912
APZ21230/4-1306
APZ21230/4-1315
APZ21230/4-1331
APZ21230/4-1340
APZ21230/4-1101
APZ21230/4-1178
APZ21230/4-1329
APZ21230/4-1222
APZ21240/3-172
APZ21230/4-1100
APZ21230/4-1313
73
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
74 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
74
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
75 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
F:\temp>sfcstate
Soft function change is in state 'Supervision'.
F:\temp>sfcfb
or sfcend
5.14
Both nodes
Remove installation files:
C:\>rd c:\temp /s /q
RESULT:
Prompt is returned.
C:\>md c:\temp
RESULT:
Prompt is returned.
C:\>rd f:\temp /s /q
RESULT:
75
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
76 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Prompt is returned.
C:\>md f:\temp
RESULT:
Prompt is returned.
C:\>rd /S /Q C:\$OEM$
Note: (Run only if the C:\$OEM$ folder exists)
RESULT:
Prompt is returned.
_
Active node
F:\temp>rd /S /Q G:\fcr_upgrade
RESULT:
Prompt is returned.
5.15
5.16
Both nodes
Check for the hwver version
C:\>hwver
RESULT:
AP HARDWARE VERSION
APG40C/4 or APG40C/2
If the result printout is C/2 proceed with the next command
Execute the given command to free space on C:\ drive
76
Ericssonwide Internal
77 (80)
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
C:\>compact /C c:\ACS\data\FCH\current\*.* /s
Note: This step can be executed on both nodes simultaneously and this
takes around 5 minutes.
RESULT:
Compressing files in c:\ACS\data\FCH\current\
cxc1060053
0 :
0 = 1.0
cxc1060054
0 :
0 = 1.0
cxc1060055
0 :
0 = 1.0
cxc1060074
0 :
0 = 1.0
cxc1060087
0 :
0 = 1.0
CXC1325239
0 :
0 = 1.0
cxc1371001
0 :
0 = 1.0
cxc1371002
0 :
0 = 1.0
CXC1371004
0 :
0 = 1.0
cxc1371006
0 :
0 = 1.0
cxc1371007
0 :
0 = 1.0
cxc1371010
0 :
0 = 1.0
CXC1371016
0 :
0 = 1.0
CXC1371023
0 :
0 = 1.0
CXC1371031
0 :
0 = 1.0
CXC1371057
0 :
0 = 1.0
CXC1371059
0 :
0 = 1.0
CXC1371062
0 :
0 = 1.0
CXC1371063
0 :
0 = 1.0
CXC1371064
0 :
0 = 1.0
CXC1371065
0 :
0 = 1.0
CXC1371068
0 :
0 = 1.0
cxc1371077
0 :
0 = 1.0
CXC1371079
0 :
0 = 1.0
cxc1371080
0 :
0 = 1.0
CXC1371081
0 :
0 = 1.0
CXC1371082
0 :
0 = 1.0
CXC1371083
0 :
0 = 1.0
cxc1371084
0 :
0 = 1.0
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK
5.17
77
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
78 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
Security
Ericsson is advising against using insecure access protocols such as MTS,
FTP and Telnet, recommending all customers to use SFTP and SSH as
standard protocols when communicating with the APG. New APG systems
are delivered with the insecure access protocols disabled.
The system should be configured as required by the customer. A customer
requirement that insecure access protocols should be turned on should be
documented in a written statement.
The current status of the access protocols is available by following the
OPERATIONAL INSTRUCTION : 11/154 31-CNZ 222 89 Uen A
Blocking of Insecure Protocols, Verify.
The insecure access protocols are turned off by following the
OPERATIONAL INSTRUCTION 9/154 31-CNZ 222 89 Uen A Blocking of
Insecure Protocols, Initiate.
The insecure access protocols should only be turned on if the customer has
explicitly stated that. Usually this implies that the other nodes in the customer
network have insecure protocols enabled.
The insecure access protocols are turned on by following the
OPERATIONAL INSTRUCTION, 10/154 31-CNZ 222 89 Uen A
Blocking of Insecure Protocols, End. Note that it can take minutes before
the change is deployed in the whole APG.
APPENDIX A
78
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
79 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
79
Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)
80 (80)
No.
HY/XCS XCSGASA
019/1531-5/LZY242060/1
Approved
Checked
Date
Rev
TEI/XST B. Pappalardo
XCSSISU
2010-01-12
Reference
South America:
E. South America Standard Time
Central Brazilian Standard Time
Adjusts DST start dates and end dates for the Brasilia time zone and for the
Manaus time zone for changes after the prior cumulative time zone update
was created (August 2007).
Venezuela Standard Time:
Adds a new time zone for the Caracas time zone for changes after the prior
cumulative time zone update was created (August 2007).
Note: This time zone update occurs on December 9, 2007 at 3:00:00.
References
[1] 2/1551-5/LZY 242 060/21 Uen Software Record APG40 one track AP1
AGM018
[2] 2/1551-5/LZY 242 060/41 Uen Software Record APG40 one track AP1
AGM018
[3] 1551-5/LZY 242 060/1 Uen Reference Package for APG40 one track AP1
AGM019 for both C/2 and C/4 LBB
[4] 3/15431-CNZ 22281, APG40, Soft Function Change, Parameter, Change
[5] 2/154 31-CNZ 222 105 Uen, AP, Function Change Reference Package,
Manual Restore.
[6] 12/154 31-CNZ 222 89 Uen
AP, Antivirus Signature Update, Administrate for CA 8.1
80