You are on page 1of 80

Ericssonwide Internal

INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

1 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Update of APG40 AP1 software from APG40 One


Track AGM018 to AGM019
This document is valid for the Windows 2003 based Adjunct Processor (AP).
It specifies the update of APM, APIO & STS AP software. The update is from
5/LZY 242 060/21 R1F (APG40 One Track AGM018) to 5/LZY 242 060/21
R1G (APG40 One Track AGM019 Rev C) for APG40 with C/2 LBB and from
5/LZY 242 060/41 R1F (APG40 One Track AGM018) to 5/LZY 242 060/41
R1G (APG40 One Track AGM019 Rev C) for APG40 with C/4 LBB.
Application
This section contains the applicability of the document on various
configurations.
This document is applicable for the update of APG40 software from AGM018
to AGM019 on C/2 and C/4 AP1 configurations.
Note: If the node base level before update of AGM019 is AGM018 +
UAM002 then installation of UAM002 should be done again after
updating the node to AGM019 (TR HK91059).

Revision History

Rev.

Date

Prepared

Description

2008-10-27

XCSVIVO

Firm Revision

2008-11-07

XCSVIVO

Added Appendix A chapter


as STS Workaround for BSC
customers applicable for only
APG40 C/2 hardware
Added Workaround for OSSTectia compatability issue
updated fcr_start and
fcr_continue files by including
srvany.exe and
TectiaWrapper.reg files inside
Updated swrprod bat files by
updating the AGM019 marker as
R1B

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

2 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Rev.

Date

Prepared

Description

2009-02-23

XCSGASA

Removed SSH cnis, CDHBIN


and FTPCLIBIN cnis.and added
new CNI.Please refer to Change
Message document 019/109 22APZ 212 30/56-A00

2009-03-10

XCSGASA

Added chapter 5.4 as a wa for


TR HK29936 (account password
reset)

2009-05-20

XCSGASA

Added steps 56, 57, 61,62,66


and 83 to implement TR
HK58300 and HK55616.
Modified step 70 to correct step
number.
Modified beginning of paragraph
5.2 implementing a failover

2009-06-03

EALOFAL

Added steps 11 and 34

2009-09-15

XCSVIVO

Modified chapter 5.9 step 63 to


execute it only in some condition
Application section modified with
respect to base line AGM018 +
UAM002 according to TR:
HK91059
Modified Chapter 5.4 including a
possible printout given if
AGM018 + UAM004 is used as
install base
Modified Step 4 in Chapter 5.9
adding instruction to manage
R3.5 for some particular cases.

2009-09-30

XCSVIVO

Modified the UI as per the new


update package ( Rev E)
information. Update package is
modified with new preFCR.exe

2009-12-14

XCSGASA

Moved Step 45 and 46 to Step


42 and 44. Added step 43
according to TR: HL20339

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

3 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Rev.

Date

Prepared

Description

2010-01-12

XCSNIKU

Modified step 75 and step 76 in


chapter 5.9 to allow the user to
change the caucasus timezone
and to recreate the timezone
association between CPand AP.

Contents
This section will contain the contents (Sections and sub-sections) of the
update document.

Overview on the update procedure


This update procedure is divided into four main steps:

HealthCheck

FCR

Installation of LBB CN-I`s

Executing swrprod

Convention
Commands are always in boldface, font used is Courier New, and written on a
new line. Command printout is in italics and the font is Courier New.

Application
This document shall be used for update of customer sites as well as system
test sites.

Prerequisites

4.1

Attributes of the Update Procedure


APZ level: APZ 12.0 CPM018

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

4 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

APG level: Ref [1] 2/1551-5/LZY 242 060/21 Uen Software Record APG40
one track AP1 AGM018 for APG40 with C/2 LBB and Ref [2] 2/1551-5/LZY
242 060/41 Uen Software Record APG40 one track AP1 AGM018 for APG40
with C/4 LBB.
Update time:
The complete installation including FCR upgrade with 15 minutes supervision
period and without burbackup will take approximately 193 minutes for C/2 and
156 minutes for C/4 machines.

4.2

Update Package
The AGM019 package size is 450 MB.
The C:\temp, and F:\temp are used during the update and these must exist.
The free disk space needed during the installation is 600 MB on C and F
drives and 800 MB on G drive. The package should be stored on G:\Ftpvol.
G:\ftpvol, F:\TEMP and C:\TEMP should be empty before the start of the
Installation procedure.
Necessary package fetched from GASK archive as PKZIP (WINZIP) format
019/19099-5/LZY242060 Revision E. The name of the update installation
package file may vary depending on which tool is used when fetching it from
GASK. In this document named as 019_19099-5_LZY242060_E.zip.
Package information can be found in Ref [3] 1551-5/LZY 242 060/1 Uen
Reference Package for APG40 one track AP1 AGM019 for both C/2 and C/4
LBB.

4.3

Known bugs and limitations

If the update is performed during the DST period of a timezone then


there is a jump of 1 hour in the scheduled downloads for engine and
signatures. Refer TR HK23216 for details.

Design rule violation in printout for swrprint command for CPHWBIN


(CNI : 40/2-178). Refer TR HK24129 for details.

Design rule violation in printout for swrprint command for


IPNA_INETBIN(CNI: 30/4-920). Refer TR HK24133 for details.

Tapes get ejected at C/2 sites when loading package. CNI 10922APZ212 30/4-1076, which installs the tape firmware version L411 on
APG40 C/2 systems, will eject any medium present in the tape drive.

MKTR does not fetch FCR logs. Refer TR HK28809

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

5 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

AGM019 ACL are not according to design rule. By the way, there are
no drawbacks for customer application. Refer TR HK28561 for details.

After Update while taking backup an error message is given


"SetFileSecurity on D:\Program Files\F-Secure\ssh server\hostkey
returned error 5 "
The printout will not harm the backup operation that will be completed
successfully. Refer TR HK14453 for details.

4.4

Possible issues happened sporadically when installing specific


packages.

A P4.1 installation failure has been verified when the green LED on tape
drive was always OFF and the amber LED was always ON (none of them
were flashing).
The amber LED Light indicates a "Media Caution" signaled for this DAT
drive prior to the upgrade, in details it means:
Flash Amber: Cartridge is near the end of its life or the heads need
cleaning.
Steady Amber: Hard fault
The drive monitors the number of correctable errors that occur during
reading and writing.
If the number of errors grows excessively, it can mean that the tape is
nearing the end of its useful life, or that the tape heads need cleaning.
The Media Caution signal is cleared when a new tape is loaded or when
the drive is power-cycled

4.5

Health Check

Before starting the update run the latest revision of ALAN tool and correct
the faults as indicated. Run the ALAN after update and compare the
analysis results.

Before starting the update execute the following command to check that
the account password doesnot expires during the update
C:\>dsquery computer -stalepwd 25

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

6 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

If the number of days is 25 or more, apply primus solution SCS791088 to


reset the machine account before starting the update. Refer TR HK29936
for details

4.6

Content of update package

4.6.1

Included CNIs

Name

Package

Rev

R-State

CNI-no
APZ212 XX/X

LBB

31/19089-LZY 214 3173

R1BS

30/4-1216

LBB

28/19089-LZY 214 3173

R1BX

30/4-1026

LBB

41/19089-LZY 214 3360

R1AF

30/4-1076

LBB

411/19089-LZY 214 3360

R1AF

30/4-1076

LBB

311/19089-LZY 214 3173

R1BN

30/4-1233

LBB

310/19089-LZY 214 3173

R1BM

30/4-1217

LBB

313/19089-LZY 214 3173

R1BU

30/4-1259

LBB

318/19089-LZY 214 3173

R1BY

30/4-1278

LBB

317/19089-LZY 214 3173

R1CD

30/4-1305

LBB

33/19089-LZY 214 3173

R1CF

30/4-1341

ACSBIN

CXC1371068/5

R9B

30/4-1354

AEHBIN

CXC137 90/4

R5B

30/4-1272

AFPBIN

CXC137 1083/5

R2H

30/4-1337

ALOGBIN

CXC1371092/5

R3A

30/4-1114

ASECBIN

CXC1371016/4

R5B

30/4-1287

AVIRBIN

CXC1371268/4

R1A

30/4-1240

BURBIN

CXC1371062/5

AS

R6C

30/4-1299

BURREMRECBIN CXC1371103/5

R3A

30/4-1280

CXC1371084/5

R6B

30/4-1345

CDHBIN

Ericssonwide Internal
7 (80)

INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

CHBBIN

CXC137433/4

R7S

30/4-1232

EMFBIN

CXC1371111/5

B2

R2C

30/4-1230

FCHBIN

CXC1371136/5

B2

R3A

30/4-1156

FCRBIN

CXC1371117/5

R2C

30/4-1310

FTPCLIBIN

CXC1371095/5

R2D

30/4-1346

IPNAADMBIN

CXC 1371259/5

R1B

30/4-1205

LCTBIN

CXC1371063/5

R4A

30/4-1344

LOGMBIN

CXC1371079/4

R2D

30/4-1301

NETCFGBIN

CXC1371125/5

R1E

30/4-1356

NSFBIN

CXC 1371091/5

L2

R6B

30/4-1358

PRCBIN

CXC1371059/4

AC2

R8A

30/4-1271

RTRBIN

CXC1371096/5

R4J

30/4-1145

SSUBIN

CXC1371104/5

R3A

10/4-1262

SWRBIN

CXC 1371064/5

D4

R4A

30/4-1226

TOCAPBIN

CXC137611/5

R1C

30/4-1304

TRAINIBIN

CXC13789/4

R1B

30/4-1253

USABIN

CXC1371081/5

R7B

30/4-1353

AISAPIBIN

CXC137425

R3E

30/4-1315

ALECADMBIN

CXC137479/4

R1M

30/4-1222

CPHWBIN

CXC1371010/4

R5B

40/2-178

MCCBIN

CXC137429/4

R4N

30/4-1331

MLSMMLBIN

CXC137430/4

BE

R4AN

30/4-1340

MLSMTSBIN

CXC137474/4

BH

R4J

30/4-1329

MMLAPIBIN

CXC137418/4

R5C

30/4-1306

STSCBIN

CXC 137 1243/5

R1G

30/4-1313

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

8 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

STSCOUNT01

CXC 137 1167/5

R1H

30/4-1317

STSCOUNT02

CXC 137 1168/5

R1G

30/4-1318

STSCOUNT03

CXC 137 1169/5

R1G

30/4-1319

STSCOUNT04

CXC 137 1206/5

R1K

30/4-1320

STSCOUNTERS

CXC1371179/5

R1K

30/4-1316

4.6.2

Included files
Note: The folder F:\TEMP shall contain files
apg40_inf_restore.bat
AVIRPATH_check_on_C.vbs
avirbin_Path_Update_on_D.vbs
avirbin_fix.bat
avirbin_reg.reg
busrv.vbs
ChangeTZ.exe
create_dir.vbs
cxc1371268.par
exteldec.bat
extelinc.bat
extelval.bat
fcr.vbs
fcr_delete_user.vbs
F-Secure-Infinite-Idle.vbs
preFCR.exe
restore_hostkey.bat
save_hostkey.bat
save_system_settings.bat
start_stop_cps.bat
swrprod_agm019_AP1.bat
swrprod_agm019_AP2_AP3.bat
telinc.reg
Note: The folder F:\TEMP\Script_1289 shall contain files
100_19089_CXC1371091_5.vbs
install.bat
Note: The folder F:\TEMP\CPS shall contain files
common_Buap.reg
common_Busrv.reg

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

9 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Note: The folder F:\TEMP\AP2 shall contain files


system.cfg
Note: The folder F:\TEMP\AP3 shall contain files
system.cfg
Note: The folder F:\TEMP\SetCAGMTScheduleTime shall contain files
BFS
RFE.vbs
SetCAGMTScheduleTime.bat
SetCAGMTScheduleTime.dft
SetCAGMTScheduleTime.sfs
Note: The folder F:\TEMP\R35Patch shall contain files
R35.txt
R35PatchForAGM019.bat
4.6.3

Content of included file


swrprod_agm019_AP1.bat
@echo off
swrprod -n "LBBCNI" "CRZ 222 05" " "
swrprod -r "APM 5.0.5" 5/LZY242113/1 R1F
IF ERRORLEVEL 1 GOTO END1
swrprod -r "APIO 4.0.4" 5/LZY242113/2 R1E
IF ERRORLEVEL 1 GOTO END2
swrprod -n "APM 5.0.6" 5/LZY242113/1 R1G
IF ERRORLEVEL 1 GOTO END1
swrprod -n "APIO 4.0.5" 5/LZY242113/2 R1F
IF ERRORLEVEL 1 GOTO END2
swrprod | findstr AGM | find "018"
goto AGM6%ERRORLEVEL%
:AGM60
swrprod | findstr AGM | find "018" | findstr R1A
goto AGM61%ERRORLEVEL%
:AGM610
swrprod -r "AGM" "018" "R1A"
IF ERRORLEVEL 1 GOTO END00
swrprod -n "AGM" "019" "R1E"
IF ERRORLEVEL 1 GOTO END4
goto ENDPP1
:AGM611
swrprod | findstr AGM | find "018" | findstr R1B
goto AGM62%ERRORLEVEL%
:AGM620
swrprod -r "AGM" "018" "R1B"
IF ERRORLEVEL 1 GOTO END00

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

10 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

swrprod -n "AGM" "019" "R1E"


IF ERRORLEVEL 1 GOTO END4
goto ENDPP1
:AGM621
swrprod | findstr AGM | find
goto AGM63%ERRORLEVEL%
:AGM630
swrprod -r "AGM" "018" "R1C"
IF ERRORLEVEL 1 GOTO END00
swrprod -n "AGM" "019" "R1E"
IF ERRORLEVEL 1 GOTO END4
goto ENDPP1
:AGM631
swrprod | findstr AGM | find
goto AGM64%ERRORLEVEL%
:AGM640
swrprod -r "AGM" "018" "R1D"
IF ERRORLEVEL 1 GOTO END00
swrprod -n "AGM" "019" "R1E"
IF ERRORLEVEL 1 GOTO END4
goto ENDPP1
:AGM641
goto END00
:AGM61
goto END00
:ENDPP1
swrprod | findstr IAM >NUL
goto IAM%ERRORLEVEL%
:IAM0
swrprod | findstr IAM | find
goto IAM7%ERRORLEVEL%
:IAM70
swrprod -r "IAM" "016" " "
goto END8
:IAM71
swrprod | findstr IAM | find
goto IAM8%ERRORLEVEL%
:IAM80
swrprod -r "IAM" "017" " "
goto END8
:IAM81
swrprod | findstr IAM | find
goto IAM9%ERRORLEVEL%
:IAM90
swrprod -r "IAM" "018" " "
goto END8
:IAM91
swrprod | findstr IAM | find
goto IAM10%ERRORLEVEL%
:IAM100
swrprod -r "IAM" "019" " "
goto END8

Reference

"018" | findstr R1C

"018" | findstr R1D

"016"

"017"

"018"

"019"

10

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

11 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

:IAM101
swrprod | findstr IAM | find "020"
goto IAM11%ERRORLEVEL%
:IAM110
swrprod -r "IAM" "020" " "
goto END8
:IAM111
swrprod | findstr IAM | find "021"
goto IAM12%ERRORLEVEL%
:IAM120
swrprod -r "IAM" "021" " "
goto END8
:IAM121
swrprod -r "IAM" " " " "
goto END8
:IAM1
goto END11
:END8
swrprod -n "IAM" " " " "
:END9
echo Update system identity
swrsid -n "APG40 One Track AGM019 AP1"
IF ERRORLEVEL 1 GOTO END5
echo "Done!"
GOTO END
:END00
echo Error!!! The swrprod for AGM is either incorrect or
not present
echo Please check with the earlier version of software
print
GOTO END
:END1
echo Error!!! The swrprod for APM is either incorrect or
not present
echo cannot remove the software product identification
for APM.
echo Please check with the earlier version of software
print
GOTO END
:END2
echo Error!!! The swrprod for APIO is either incorrect or
not present
echo cannot remove the software product identification
for APIO.
echo Please check with the earlier version of software
print
GOTO END
:END4
echo Error!!! The swrprod command for adding AGM identity
failed
GOTO END
:END5

11

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

12 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

echo Error!!! The swrprod command for adding swrsid


failed
GOTO END
:END11
echo Error!!! Incorrect Base Level
:END12
echo Error!!! The swrprod command for adding LBB failed
GOTO END
:END

Installation Procedure
NOTE: The logon of a node shall be performed as a user, remotely by using
telnet or Winfiol .This user can be administrator. It can also be another user
that belongs to the groups Administrators & Domain Admins .
Check using following commands whether the user being used to do the
update belongs to the group Domain Admins
F:\TEMP>net group Domain Admins
If the user is not a member of the groups mentioned above, run the following
commands to add user to the groups
Note:For this logon should be done as administrator
F:\TEMP>net group "Domain Admins" <user name> /add

5.1

Burbackup before installation


A full backup of the entire system should be taken before starting with the
installation procedure.
Execute the command on one of the nodes
F:\TEMP>Burbackup o
RESULT:

Execute burBackup with these parameters:


burbackup -o
[y=yes, n=no]?:yes
Answer with yes to continue

12

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

5.2

13 (80)

Reference

Disable Automatic Backup

Active node
Perform a failover.This step could avoid a possible soft function change failure
due to long time needed to set cluster resources off line.
Log on and verify that the node is active.
C:\>prcstate
RESULT:

Active
Perform a failover
C:\>prcboot f
RESULT:

REBOOT INITIATED!....
Wait approximately 7 minutes from the time of reboot.
Active node
Log on to (new) active node after the reboot and verify that the node has
started in passive mode.
C:\>prcstate
RESULT:

Active
Disable the automatic backup.
F:\Temp>sfcstate
RESULT:

No soft function change session is in progress.


F:\Temp >sfcexec
RESULT:
NOTE: The session can be aborted at any time before
switch to
the new system has been ordered. Press Ctrl+C and ENTER
to abort.

Would you like to copy parameter files from disk?


[y(es)/n(o)]:n
Would you like to edit parameter files? [y(es)/n(o)]:y

13

Ericssonwide Internal
14 (80)

INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Choose one of the packages to upgrade parameters in:


NO

CXCNUMBER

MODULENAME

REVISION

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

CXC1371062
CXC1371065
CXC1371096
CXC1371147
CXC137440
CXC1371084
CXC1371087
CXC1371088
CXC1371094
CXC1371097
CXC1371100
CXC1371057
CXC1371002
CXC1371004
CXC1371077
CXC137418
CXC137425
CXC137429
CXC137430
CXC137431
CXC137471
CXC137474
CXC137479
CXC1371102
CXC1371140
CXC1371243

BURBIN
AVIRBIN
RTRBIN
APCONFBIN
ACABIN
CDHBIN
DBOBIN
GCCBIN
SSHSERVBIN
CPFADMBIN
FCCAPIBIN
CPTASPBIN
ALDABIN
ALISADMBIN
MLSMSSBIN
MMLAPIBIN
AISAPIBIN
MCCBIN
MLSMMLBIN
PDSPGMBIN
ADHADMBIN
MLSMTSBIN
ALECADMBIN
CLHADMBIN
SGSBIN
STSCBIN

R6A
R5A
R4H
R1D
R6D
R5A
R1D
R1C
R1F
R1J
R1C
R5C
R1E
R2E
R2C
R5B
R3D
R4M
R4AL
R4D
R3H
R4F
R1L
R2D
R1D
R1E

CNI

APZ21230/4-1084
APZ21230/4-1165
APZ21230/4-1082
APZ21230/4-1153
APZ21230/4-1174
APZ21230/4-1202
APZ21230/4-1151
APZ21230/5-485
APZ21230/4-1000
APZ21230/4-836
APZ21230/4-990
APZ21230/6-912
APZ21230/6-897
APZ21230/4-807
APZ21230/4-1179
APZ21230/4-1007
APZ21230/4-1101
APZ21230/4-1178
APZ21230/4-1123
APZ21230/4-1013
APZ21240/3-172
APZ21230/4-1100
APZ21230/4-1144

Edit the BURBIN package to upgrade parameters


Enter a number for the package to upgrade parameters in
or
enter 'c(ontinue)' to continue soft function change
session.
:1
Parsing format file ...
Parsing parameter file ...
Parameter editing session started.
:list
ACS_BUR_archive_backup
ACS_BUR_archive_bkp_freq
ACS_BUR_backup_window_min
ACS_BUR_bkp_start_hour
ACS_BUR_bkp_start_min
ACS_BUR_max_archive_bkps
ACS_BUR_system_backup

14

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

15 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

ACS_BUR_system_bkp_freq
Edit the parameters for ACS_BUR_archive_backup and
ACS_BUR_system_backup to 0 to disable the automatic
backup.
:edit ACS_BUR_archive_backup
Category: Private
unsignedShortInt[0, 1] (1):0
:edit ACS_BUR_system_backup
Category: Private
unsignedShortInt[0, 1] (0):0
:end
Parameters updated
Exiting ...
Would you like to edit more parameter files?
[y(es)/n(o)]:n
System upgrade performed. Would you like to switch to the
new system,
thereby starting the supervision period? (No will abort
and restore
the system. [y(es)/n(o)]:y
Parameter tables generated. No errors found.
Change of parameter(s) succeeded, supervision period has
started.
Execute sfcend when supervision period is over.
F:\temp>sfcstate
Soft function change is in state 'Supervision'.
F:\temp>sfcend
Soft function change session has ended.

5.3

Extract update file

Active node
Extract the update package file to the temp directory on G:\ drive.
F:\temp>pkzipc -extract -dir
-over=all \\clustername\G$\ftpvol\019_190995_LZY242060_E.zip G:\temp
RESULT:

15

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

16 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Example result from active node


PKZIP(R)
Windows

Version 6.0

FAST!

Compression Utility for

Copyright 1989-2002 PKWARE Inc.


Registered Version

All Rights Reserved.

PKZIP Reg. U.S. Pat. and Tm. Off.

Patent No. 5,051,745

Masking file attributes: Read-Only, Hidden, System,


Archive
Extracting files from .ZIP:
\\clustername\G$\ftpvol\019_19099-5_LZY242060_E.zip
Extracting: G:/temp/fcr_upgrade.zip
Extracting: G:/temp/fcr_upgrade_C2.zip
Extracting: G:/temp/lbb.zip
Both nodes
Extract the LBB package to F:\temp
F:\TEMP>pkzipc -extract -dir
-over=all \\clustername\G$\temp\lbb.zip F:\temp
RESULT:

Printout too long to be added here.


Active Node
Extract the FCR reference package file to G: drive
F:\TEMP>pkzipc -extract -dir -over=all
G:\temp\fcr_upgrade.zip G:\
RESULT :

Printout too long to be added here.


Delete the update package files from G:\Ftpvol remove the zip file
F:\TEMP>Del g:\ftpvol\019_19099-5_LZY242060_E.zip
RESULT:

Prompt is returned
Delete the G:\temp folder
F:\temp>rd /S /Q G:\TEMP

16

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

17 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

RESULT:

Prompt is returned

5.4

Save Customer Specific Settings

Both nodes
This .bat file saves the SSH, Telnet and apg40.inf settings
F:\TEMP>save_system_settings.bat
RESULT:

1
1
1
1

file(s)
file(s)
file(s)
file(s)

copied.
copied.
copied.
copied

Verify the execution of the command


F:\temp>echo %errorlevel%
The result should be 0.
If the execution of batch file fails with error Error!!! Failed to copy
inodist.ini from C:\Program Files\CA\eTrust Antivirus then continue with
the following set of commands
a) Check with the base for UAM004
F:\TEMP>swrsid
If the system is on UAM004 base only then continue with the following
command
F:\TEMP>cscript C:\acs\data\avir\eTrustSaveProxy.vbs
F:\TEMP>Copy "C:\acs\data\avir\inodist.ini" F:\Temp
Result:
1 file(s) copied

5.5

Extend idle timeout

Both nodes
Update with SSH application
Note: This step should only be done if connecting to the AP using SSH
protocol.
Install configuration file with extended idle timeout:

17

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

18 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

F:\TEMP>F-Secure-Infinite-Idle.vbs
RESULT:

Successfully updated the timeout to Infinite...


To apply the new settings for idle timeout a new session must be started, log
out and then log in again.
Update with Telnet application :
Save original configuration values:
F:\TEMP>extelval.bat
This command will create the teldec.reg file under F:\TEMP directory.
Extend the telnet session by using the following command:
F:\TEMP>extelinc.bat
To apply the new settings for idle timeout a new session must be started, log
out and then log in again.

5.6

Note Firmware Revisions before Start

Both nodes
NOTE: Please note the firmware versions (RAID-FW, AM-FW and CPU BIOS)
before starting the update procedure. These values are required to decide on
actions during a fallback, in case.
Check the hardware version
C:\>hwver
RESULT:
AP HARDWARE VERSION

APG40C/4 or APG40C/2
Print the RAID FW version for C/2
C:\>raidutil K
RESULT:
Address
Manufacturer/Model
FW
Cluster Suppor
----------------------------------------------d0
DPT
PM3757U2
FT0A Enabled

Print the RAID FW version for C/4

18

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

19 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

C:\>megarc -ctlrinfo -a0


RESULT:

*********************************************************
*************
MEGARC MegaRAID Configuration Utility(NT)1.14_Wrap1.0.3(2-17-2006)
By LSI Logic Corp.,USA
*********************************************************
*************
[Note: For SATA-2, 4 and 6 channel controllers, please
specify
Ch=0 Id=0..15 for specifying physical drive(Ch=channel,
Id=Target)]
Type ? as command line arg for help
*********************************************************
*************
Information of Adapter-0 (#Adapter(s) on system: 1)
*********************************************************
*************
Firmware Version : 414#
BIOS Version : H429
Logical Drives : 03
DRAM : 128MB
Rebuild Rate : 50%
Flush Interval : 4 secs
Number Of Chnls : 2
Bios Status :
Disabled
Alarm State : Disabled
Auto Rebuild :
Enabled
FW : SPAN-8, 40-LD
BIOS Config
AutoSelection : DISK
BIOS Echos Mesg : ON
BIOS Stops On
Error : OFF
Initiator Id : 7(Clustered Firmware)
Board SN:
*********************************************************
*************
Exiting with 0
Print the AM version
C:\>fcc_amversion own
RESULT:

1.13
Print the CPU BIOS version (only on C/4)
C:\>wmic bios list BRIEF

19

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

20 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

RESULT:
Manufacturer Name SerialNumber SMBIOSBIOSVersion Version
Phoenix Technologies LTD Phoenix NoteBIOS 4.0 Release 6.0
Not Applicable 2.0.5B PTLTD - 6040000

5.7

Note CP-AP association before update

Active node
C:\>mtzln p
RESULT:
TMZ : TZ
-----------------------------------0 = (GMT+01:00) Amsterdam, Berlin, Bern, Rome,
Stockholm, Vienna
Executed
Note: This is an example printout.
Note the output of the above command as it will be required in the fallback
procedure

5.8

Check for Replication

5.8.1

Active Directory Replication

Both Nodes
Verify in the following way that the replication is without errors
C:\>cd C:\Program files\Force\frconfig\domainrename
RESULT:
C:\Program files\Force\frconfig\domainrename>
C:\Program files\Force\frconfig\domainrename>repadmin
howrepl

/s

RESULT:
repadmin running command /showrepl against server
localhost
Default-First-Site-Name\AP10B
DC Options: (none)
Site Options: (none)
DC object GUID: e319fc1a-cbca-4444-b9bc-a7a1eb2a5737
DC invocationID: 954ea6e9-5120-47ed-8dbb-eb25ab1c1303
==== INBOUND NEIGHBORS=============================
DC=ap10dom,DC=int
Default-First-Site-Name\AP10A via RPC

20

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

21 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

DC object GUID: 5f3b668f-16b6-422d-8097bdd02910cd00


Last attempt @ 2008-04-10 14:14:35 was
successful.
CN=Configuration,DC=ap10dom,DC=int
Default-First-Site-Name\AP10A via RPC
DC object GUID: 5f3b668f-16b6-422d-8097bdd02910cd00
Last attempt @ 2008-04-10 13:53:20 was
successful.
CN=Schema,CN=Configuration,DC=ap10dom,DC=int
Default-First-Site-Name\AP10A via RPC
DC object GUID: 5f3b668f-16b6-422d-8097bdd02910cd00
Last attempt @ 2008-04-10 13:53:21 was
successful.
DC=ForestDnsZones,DC=ap10dom,DC=int
Default-First-Site-Name\AP10A via RPC
DC object GUID: 5f3b668f-16b6-422d-8097bdd02910cd00
Last attempt @ 2008-04-10 13:53:21 was
successful.
DC=DomainDnsZones,DC=ap10dom,DC=int
Default-First-Site-Name\AP10A via RPC
DC object GUID: 5f3b668f-16b6-422d-8097bdd02910cd00
Last attempt @ 2008-04-10 13:53:21 was
successful.
If there is no replication between the nodes before the installation starts,
the installation may fail. Ensure that replication is working
between the two nodes before starting the installation.
This check shall be performed on both nodes.
Start replication of the node:
C:\Program files\Force\frconfig\domainrename>repadmin
/syncall <nodename> /A
RESULT:
CALLBACK MESSAGE: The following replication is in
progress:
From: b9352ede-04aa-478c-a03b23292cf0c98a._msdcs.ap212dom.int
To : c368391d-3f05-414b-8e99829483a2b432._msdcs.ap212dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: b9352ede-04aa-478c-a03b23292cf0c98a._msdcs.ap212dom.int
To : c368391d-3f05-414b-8e99-

21

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

22 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

829483a2b432._msdcs.ap212dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors
This doesn't solve any replication problems. It only facilitates
replication to happen at that moment (without waiting for the scheduled
replication) provided there are no replication problems, and thus avoids
situations like the user being found in one node and not found in the
other. Basically it will synchronize the active directory details
instantaneously. If a machine is not able to replicate this means that
there is some fault with the machine (probably caused due to a bad
restore or due to some other reason).
If there is no replication between the nodes before the installation
starts, the installation may fail. If there is a problem with replication contact
the next level of support.
5.8.2

File Replication
C:\Program files\Force\frconfig\domainrename>f:
F:\>Cd Temp
Verify in the following way that the File replication is without errors.
Create two files to test File Replication:
NodeA
F:\TEMP>copy
nul \\192.168.202.1\c$\winnt\sysvol\domain\scripts\testa.
txt
RESULT:
1 file(s) copied.
NodeB
F:\TEMP>copy
nul \\192.168.202.2\c$\winnt\sysvol\domain\scripts\testb.
txt
RESULT:
1 file(s) copied.
Verify if BOTH created files are present in BOTH nodes:
NodeA
F:\TEMP>dir \\192.168.202.1\c$\winnt\sysvol\domain\script
s\
RESULT:
Volume in drive \\192.168.202.1\c$ is ntserv
Volume Serial Number is 8045-1876
Directory
of \\192.168.202.1\c$\winnt\sysvol\domain\scripts
04/10/2008 02:20 PM
<DIR>
.
04/10/2008 02:20 PM
<DIR>
..

22

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

23 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

04/25/2002 01:53 PM
acs_acsc_warning.bat
04/10/2008 02:20 PM
04/10/2008 02:20 PM
3 File(s)
2 Dir(s)

Reference

114
0 testa.txt
0 testb.txt
114 bytes
1,362,063,360 bytes free

NodeB
F:\TEMP>dir \\192.168.202.2\c$\winnt\sysvol\domain\script
s\
RESULT:
Volume in drive \\192.168.202.2\c$ is ntserv
Volume Serial Number is 8045-1876
Directory
of \\192.168.202.2\c$\winnt\sysvol\domain\scripts
04/10/2008 02:20 PM
<DIR>
.
04/10/2008 02:20 PM
<DIR>
..
04/25/2002 01:53 PM
114
acs_acsc_warning.bat
04/10/2008 02:20 PM
0 testa.txt
04/10/2008 02:20 PM
0 testb.txt
3 File(s)
114 bytes
2 Dir(s)
1,362,063,360 bytes free
Remove the test files:
NodeA
F:\TEMP>del \\192.168.202.1\c$\winnt\sysvol\domain\script
s\testa.txt
RESULT:
Prompt is returned
NodeB
F:\TEMP>del \\192.168.202.2\c$\winnt\sysvol\domain\script
s\testb.txt
RESULT:
Prompt is returned
Verify if both the files are deleted in both nodes:
NodeA
F:\TEMP>dir \\192.168.202.1\c$\winnt\sysvol\domain\script
s\
RESULT:
Volume in drive \\192.168.202.1\c$ is ntserv
Volume Serial Number is F005-D27B
Directory
of \\192.168.202.1\c$\winnt\sysvol\domain\scripts
04/10/2008 07:28 PM
<DIR>
.

23

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

24 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

04/10/2008 07:28 PM
<DIR>
..
04/10/2008 12:57 PM
114
acs_acsc_warning.bat
1 File(s)
114 bytes
2 Dir(s)
1,115,570,176 bytes free
NodeB
F:\TEMP>dir \\192.168.202.2\c$\winnt\sysvol\domain\script
s\
RESULT:
Volume in drive \\192.168.202.2\c$ is ntserv
Volume Serial Number is 8045-1876
Directory
of \\192.168.202.2\c$\winnt\sysvol\domain\scripts
04/10/2008 02:21 PM
<DIR>
.
04/10/2008 02:21 PM
<DIR>
..
04/25/2002 01:53 PM
114
acs_acsc_warning.bat
1 File(s)
114 bytes
2 Dir(s)
1,362,063,360 bytes free
Note: If there is no replication between the nodes before the installation
starts, the installation may fail. If there is a problem with replication contact
the next level of support.

5.9

Update Procedure
NOTE: DO NOT use GUI during the installation.

A-node
1. Logon to node A.
Verify that the cluster group is up and running and node is passive
F:\TEMP>cluster group
RESULT:
Group

Node

Disk Group

APXXB

RGAPM_1

APXXB

Online

Cluster Group

APXXB

Online

RGAPM_0

APXXA

Online

APXXB

Online(on C/2)

PMC860 Group

Status
Online

24

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

25 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

F:\TEMP>prcstate
RESULT:

Passive
or
Active
If the result is passive, continue with step 4. If node A is active, continue with
step 2.
2. Perform a failover from node A to node B.
C:\>prcboot f
RESULT:

REBOOT INITIATED!....
Wait approximately 7 minutes from the time of reboot.
3. Log on to node A after the reboot and verify that the node has started in
passive mode.
C:\>prcstate
RESULT:

Passive
Verify that all cluster resources are online
C:\>cluster group
RESULT:
Group

Node

Disk Group

APXX
B

RGAPM_1

APXXB

Online

Cluster Group

APXXB

Online

RGAPM_0

APXXA

Online

APXXB

Online(on C/2)

PMC860 Group

Status
Online

25

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

26 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Both Nodes
4. Workaround for TR HJ56640- copy SSH hostkey to f:\temp.
F:\TEMP>save_hostkey.bat
RESULT:

1 file(s) copied.
1 file(s) copied.
Verify the execution of the command
F:\temp>echo %errorlevel%
The result should be 0.
Workaround for R35 Patch(CSR 1272722)
F:\TEMP>cd R35Patch
F:\TEMP\R35Patch>R35PatchForAGM019.bat
5. Save the ApSwFileAcl.da2 from the fcr package
F:\temp>copy
\\<clustername>\G$\fcr_upgrade\config\ApswFileAcl.da2
F:\temp
RESULT:

1 file(s) copied.
F:\temp>apaclset -b f:\temp\ApSwFileAcl.da2 -v f >
F:\temp\acl.txt q
RESULT:

Prompt is returned
6. Add the missing users
F:\temp>fcr.vbs
RESULT:

user added :<user name>


or
Prompt is returned

26

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

27 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

7. Check that services ACS_FCR_Server is running on both nodes by command:


F:\temp:\>net start | findstr ACS_FCR_Server
RESULT1:

ACS_FCR_Server

(if its started)

RESULT2:

Prompt is returned (if its stopped)


if it is not started start it by command:
F:\temp:\>net start ACS_FCR_Server
RESULT:

The ACS_FCR_Server service is starting.


The ACS_FCR_Server service was started successfully.
Passive Node
8. Take a partition backup
F:\temp:\>burbackup o p f
RESULT:

AP35B:
Parameter file for backup does not exist:
K:\APZ\DATA\BOOT
Save all disk information and runtime parameter data to
file \\AP35A\C$\acs\data\BUR\AP35A_20081217_050813.ddi
completed
Parameter file for backup does not exist:
K:\APZ\DATA\BOOT
Save all disk information and runtime parameter data to
file \\AP35B\C$\acs\data\BUR\AP35B_20081217_050813.ddi
completed
Continuing with partition backup please wait
AP35A:
burBackup partition backup completed
1769 directories and 17914 files copied or equal and 0
files locked
AP35B:
burBackup partition backup completed
1831 directories and 17955 files copied or equal and 0
files locked
burBackup one button backup execution completed

Both Nodes

27

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

28 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

9. Execute the script to update the path variable for antivirus


F:\temp:\>avirbin_Path_Update_on_D.vbs
RESULT:

Script execution starts to perform modification of Path


environment variable for antivirus CA 8.1
Loading D drive registry hive in HKLM\temp_hive

28

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

29 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

path before update for ControlSet001: %SystemRoot


%\system32;%SystemRoot%;%SystemRoot
%\System32\Wbem;c:\Program Files\PKWARE\pkzipc;c:\Program
Files\Pragma\Shared Files;c:\Program
Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
am Files\AP\ACS\bin;C:\Program
Files\AP\ACS\lib;C:\Program Files\AP\OCS\bin;C:\Program
Files\AP\OCS\lib;C:\Program Files\AP\AES\bin;C:\Program
Files\AP\AES\lib;C:\Program Files\AP\CPS\bin;C:\Program
Files\AP\CPS\lib;C:\Program Files\AP\FMS\bin;C:\Program
Files\AP\FMS\lib;C:\Program Files\AP\MAS\bin;C:\Program
Files\AP\MAS\lib;C:\Program Files\AP\MCS\bin;C:\Program
Files\AP\MCS\lib;C:\Program Files\AP\PES\bin;C:\Program
Files\AP\PES\lib;C:\Program Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\FSecure\ssh;;C:\PROGRA~1\CA\SHARED~1\SCANEN~1;C:\PROGRA~1\
CA\ETRUST~1;C:\Program Files\Intel\DMIXpath before update
for ControlSet001: %SystemRoot%\system32;%SystemRoot%;
%SystemRoot%\System32\Wbem;c:\Program
Files\PKWARE\pkzipc;c:\Program Files\Pragma\Shared
Files;c:\Program Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
am Files\AP\ACS\bin;C:\Program
Files\AP\ACS\lib;C:\Program Files\AP\OCS\bin;C:\Program
Files\AP\OCS\lib;C:\Program Files\AP\AES\bin;C:\Program
Files\AP\AES\lib;C:\Program Files\AP\CPS\bin;C:\Program
Files\AP\CPS\lib;C:\Program Files\AP\FMS\bin;C:\Program
Files\AP\FMS\lib;C:\Program Files\AP\MAS\bin;C:\Program
Files\AP\MAS\lib;C:\Program Files\AP\MCS\bin;C:\Program
Files\AP\MCS\lib;C:\Program Files\AP\PES\bin;C:\Program
Files\AP\PES\lib;C:\Program Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\FSecure\ssh;;C:\PROGRA~1\CA\SHARED~1\SCANEN~1;C:\PROGRA~1\
CA\ETRUST~1;C:\Program Files\Intel\DMIX
Found CA Path. Removing C:\PROGRA~1\CA\SHARED~1\SCANEN~1
Found CA Path. Removing C:\PROGRA~1\CA\ETRUST~1

29

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

30 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

after removing existing CA path: %SystemRoot


%\system32;%SystemRoot%;%SystemRoot
%\System32\Wbem;c:\Program Files\PKWARE\pkzipc;c:\Program
Files\Pragma\Shared Files;c:\Program
Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
am Files\AP\ACS\bin;C:\Program
Files\AP\ACS\lib;C:\Program Files\AP\OCS\bin;C:\Program
Files\AP\OCS\lib;C:\Program Files\AP\AES\bin;C:\Program
Files\AP\AES\lib;C:\Program Files\AP\CPS\bin;C:\Program
Files\AP\CPS\lib;C:\Program Files\AP\FMS\bin;C:\Program
Files\AP\FMS\lib;C:\Program Files\AP\MAS\bin;C:\Program
Files\AP\MAS\lib;C:\Program Files\AP\MCS\bin;C:\Program
Files\AP\MCS\lib;C:\Program Files\AP\PES\bin;C:\Program
Files\AP\PES\lib;C:\Program Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\F-Secure\ssh;;
path after write for ControlSet001: %SystemRoot
%\system32;%SystemRoot%;%SystemRoot
%\System32\Wbem;c:\Program Files\PKWARE\pkzipc;c:\Program
Files\Pragma\Shared Files;c:\Program
Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
am Files\AP\ACS\bin;C:\Program
Files\AP\ACS\lib;C:\Program Files\AP\OCS\bin;C:\Program
Files\AP\OCS\lib;C:\Program Files\AP\AES\bin;C:\Program
Files\AP\AES\lib;C:\Program Files\AP\CPS\bin;C:\Program
Files\AP\CPS\lib;C:\Program Files\AP\FMS\bin;C:\Program
Files\AP\FMS\lib;C:\Program Files\AP\MAS\bin;C:\Program
Files\AP\MAS\lib;C:\Program Files\AP\MCS\bin;C:\Program
Files\AP\MCS\lib;C:\Program Files\AP\PES\bin;C:\Program
Files\AP\PES\lib;C:\Program Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\F-Secure\ssh;;C:\Program
Files\CA\SharedComponents\ScanEngine;C:\Program
Files\CA\SharedComponents\CAUpdate\;C:\Program
Files\CA\SharedComponents\ThirdParty\;C:\Program
Files\CA\SharedComponents\SubscriptionLicense\;C:\Program
Files\CA\eTrustITM;

30

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

31 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

path after write for ControlSet001: %SystemRoot


%\system32;%SystemRoot%;%SystemRoot
%\System32\Wbem;c:\Program Files\PKWARE\pkzipc;c:\Program
Files\Pragma\Shared Files;c:\Program
Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
am Files\AP\ACS\bin;C:\Program
Files\AP\ACS\lib;C:\Program Files\AP\OCS\bin;C:\Program
Files\AP\OCS\lib;C:\Program Files\AP\AES\bin;C:\Program
Files\AP\AES\lib;C:\Program Files\AP\CPS\bin;C:\Program
Files\AP\CPS\lib;C:\Program Files\AP\FMS\bin;C:\Program
Files\AP\FMS\lib;C:\Program Files\AP\MAS\bin;C:\Program
Files\AP\MAS\lib;C:\Program Files\AP\MCS\bin;C:\Program
Files\AP\MCS\lib;C:\Program Files\AP\PES\bin;C:\Program
Files\AP\PES\lib;C:\Program Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\F-Secure\ssh;;C:\Program
Files\CA\SharedComponents\ScanEngine;C:\Program
Files\CA\SharedComponents\CAUpdate\;C:\Program
Files\CA\SharedComponents\ThirdParty\;C:\Program
Files\CA\SharedComponents\SubscriptionLicense\;C:\Program
Files\CA\eTrustITM;
path before update for ControlSet003: %SystemRoot
%\system32;%SystemRoot%;%SystemRoot
%\System32\Wbem;c:\Program Files\PKWARE\pkzipc;c:\Program
Files\Pragma\Shared Files;c:\Program
Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
m Files\AP\ACS\bin;C:\Program Files\AP\ACS\lib;C:\Program
Files\AP\OCS\bin;C:\Program Files\AP\OCS\lib;C:\Program
Files\AP\AES\bin;C:\Program Files\AP\AES\lib;C:\Program
Files\AP\CPS\bin;C:\Program Files\AP\CPS\lib;C:\Program
Files\AP\FMS\bin;C:\Program Files\AP\FMS\lib;C:\Program
Files\AP\MAS\bin;C:\Program Files\AP\MAS\lib;C:\Program
Files\AP\MCS\bin;C:\Program Files\AP\MCS\lib;C:\Program
Files\AP\PES\bin;C:\Program Files\AP\PES\lib;C:\Program
Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\FSecure\ssh;;C:\PROGRA~1\CA\SHARED~1\SCANEN~1;C:\PROGRA~1\
CA\ETRUST~1;C:\Program Files\Intel\DMIX

31

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

32 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

path before update for ControlSet003: %SystemRoot


%\system32;%SystemRoot%;%SystemRoot
%\System32\Wbem;c:\Program Files\PKWARE\pkzipc;c:\Program
Files\Pragma\Shared Files;c:\Program
Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
am Files\AP\ACS\bin;C:\Program
Files\AP\ACS\lib;C:\Program Files\AP\OCS\bin;C:\Program
Files\AP\OCS\lib;C:\Program Files\AP\AES\bin;C:\Program
Files\AP\AES\lib;C:\Program Files\AP\CPS\bin;C:\Program
Files\AP\CPS\lib;C:\Program Files\AP\FMS\bin;C:\Program
Files\AP\FMS\lib;C:\Program Files\AP\MAS\bin;C:\Program
Files\AP\MAS\lib;C:\Program Files\AP\MCS\bin;C:\Program
Files\AP\MCS\lib;C:\Program Files\AP\PES\bin;C:\Program
Files\AP\PES\lib;C:\Program Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\FSecure\ssh;;C:\PROGRA~1\CA\SHARED~1\SCANEN~1;C:\PROGRA~1\
CA\ETRUST~1;C:\Program Files\Intel\DMIX
Found CA Path. Removing C:\PROGRA~1\CA\SHARED~1\SCANEN~1
Found CA Path. Removing C:\PROGRA~1\CA\ETRUST~1
after removing existing CA path: %SystemRoot
%\system32;%SystemRoot%;%SystemRoot
%\System32\Wbem;c:\Program Files\PKWARE\pkzipc;c:\Program
Files\Pragma\Shared Files;c:\Program
Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
m Files\AP\ACS\bin;C:\Program Files\AP\ACS\lib;C:\Program
Files\AP\OCS\bin;C:\Program Files\AP\OCS\lib;C:\Program
Files\AP\AES\bin;C:\Program Files\AP\AES\lib;C:\Program
Files\AP\CPS\bin;C:\Program Files\AP\CPS\lib;C:\Program
Files\AP\FMS\bin;C:\Program Files\AP\FMS\lib;C:\Program
Files\AP\MAS\bin;C:\Program Files\AP\MAS\lib;C:\Program
Files\AP\MCS\bin;C:\Program Files\AP\MCS\lib;C:\Program
Files\AP\PES\bin;C:\Program Files\AP\PES\lib;C:\Program
Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\F-Secure\ssh;;

32

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

33 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

path after write for ControlSet003: %SystemRoot


%\system32;%SystemRoot%;%SystemRoot
%\System32\Wbem;c:\Program Files\PKWARE\pkzipc;c:\Program
Files\Pragma\Shared Files;c:\Program
Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
am Files\AP\ACS\bin;C:\Program
Files\AP\ACS\lib;C:\Program Files\AP\OCS\bin;C:\Program
Files\AP\OCS\lib;C:\Program Files\AP\AES\bin;C:\Program
Files\AP\AES\lib;C:\Program Files\AP\CPS\bin;C:\Program
Files\AP\CPS\lib;C:\Program Files\AP\FMS\bin;C:\Program
Files\AP\FMS\lib;C:\Program Files\AP\MAS\bin;C:\Program
Files\AP\MAS\lib;C:\Program Files\AP\MCS\bin;C:\Program
Files\AP\MCS\lib;C:\Program Files\AP\PES\bin;C:\Program
Files\AP\PES\lib;C:\Program Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\F-Secure\ssh;;C:\Program
Files\CA\SharedComponents\ScanEngine;C:\Program
Files\CA\SharedComponents\CAUpdate\;C:\Program
Files\CA\SharedComponents\ThirdParty\;C:\Program
Files\CA\SharedComponents\SubscriptionLicense\;C:\Program
Files\CA\eTrustITM;
path after write for ControlSet003: %SystemRoot
%\system32;%SystemRoot%;%SystemRoot
%\System32\Wbem;c:\Program Files\PKWARE\pkzipc;c:\Program
Files\Pragma\Shared Files;c:\Program
Files\Pragma\Clients;c:\Program
Files\Pragma\Toolkit;c:\Program
Files\Distinct\;c:\program files\dptmgr;C:\Program
Files\Common Files\DistinctShared;C:\Program
Files\Force\AM_Services;C:\Program
Files\Force\Tools;C:\PROGRA~1\DISKEE~1\DISKEE~1\;C:\Progr
am Files\AP\ACS\bin;C:\Program
Files\AP\ACS\lib;C:\Program Files\AP\OCS\bin;C:\Program
Files\AP\OCS\lib;C:\Program Files\AP\AES\bin;C:\Program
Files\AP\AES\lib;C:\Program Files\AP\CPS\bin;C:\Program
Files\AP\CPS\lib;C:\Program Files\AP\FMS\bin;C:\Program
Files\AP\FMS\lib;C:\Program Files\AP\MAS\bin;C:\Program
Files\AP\MAS\lib;C:\Program Files\AP\MCS\bin;C:\Program
Files\AP\MCS\lib;C:\Program Files\AP\PES\bin;C:\Program
Files\AP\PES\lib;C:\Program Files\AP\STS\bin;C:\Program
Files\AP\STS\lib;;C:\PROGRA~1\F-Secure\ssh;;C:\Program
Files\CA\SharedComponents\ScanEngine;C:\Program
Files\CA\SharedComponents\CAUpdate\;C:\Program
Files\CA\SharedComponents\ThirdParty\;C:\Program
Files\CA\SharedComponents\SubscriptionLicense\;C:\Program
Files\CA\eTrustITM;

33

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

34 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Verify the execution of the command


F:\temp>echo %errorlevel%
The result should be 0.
10.Execute the step to reserve the port for BUFTP (CSR 1062397)
F:\temp>preFCR.exe
RESULT:

The operation completed successfully.


Verify the execution of the command
F:\temp>echo %errorlevel%
The result should be 0
Passive A Node
11. Put diskeeper resource offline and check the status of NSF
F:\temp>cluster res diskeeper

/off /wait

F:\temp>nsfstop
RESULT:

Network surveillance not active and not started or


Network surveillance stopped or
Network surveillance already stopped
12.Start the fcr session.
C:\>fcrstart
RESULT:

Are you sure that you want to execute command 'fcrstart'?


[y(es)/n(o)]:yes
The procedure installs all CXCs including anti-virus. Installation
approximately takes10 minutes. After the installation a reboot is initiated.
Note : The node goes for reboot. Login on the node
13. Check the fcrstate .
C:\>fcrstate
RESULT:

Started or Starting
If the state is started goto step 18. If the state is starting even after 30 minutes
continue with step 14.
14. Check the hostname
C:\>hostname

34

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

35 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

RESULT:
APXXA
15. Disable and enable the replication for this host. Use hostname checked at the
previous step
C:\>cd /d "C:\program files\force\frconfig\domainrename"
C:\program files\force\frconfig\domainrename>repadmin
/options <hostname> +DISABLE_INBOUND_REPL +
DISABLE_OUTBOUND_REPL
C:\ program files\force\frconfig\domainrename>repadmin
/options <hostname> -DISABLE_INBOUND_REPL
-DISABLE_OUTBOUND_REPL
RESULT:
Current DC Options: IS_GC DISABLE_INBOUND_REPL
DISABLE_OUTBOUND_REPL
New DC Options: IS_GC
16. Force replication.
C:\program files\force\frconfig\domainrename>repadmin
/syncall /A <A-node hostname>
RESULT:
Syncing all NC's held on AP33A.
Syncing partition: DC=ForestDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=DomainDnsZones,DC=ap33dom,DC=int

35

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

36 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

CALLBACK MESSAGE: The following replication is in


progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition:
CN=Schema,CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:

36

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

37 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Note: This is an example printout
C:\program files\force\frconfig\domainrename>repadmin
/syncall /A <B-node hostname>
RESULT:
Syncing all NC's held on AP33B.
Syncing partition: DC=DomainDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=ForestDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.

37

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

38 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

SyncAll terminated with no errors.


Syncing partition:
CN=Schema,CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Note: This is an example printout.

38

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

39 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

17. Check the fcrstate .


C:\>fcrstate
RESULT:

Started
If the state is not started then wait for some time and again repeat step 17 till
state Started is reached. Even then if state Started is not reached after 40
min (since the time of reboot), then a FCR restore is required. Follow OPI for
Ref [5] AP, Function Change Reference Package, Manual Restore
18. Print the cluster group.
C:\>cluster group
RESULT:

Group

Node

Disk Group

APXXB

RGAPM_1

APXXB

Online

Cluster
Group

APXXB

Online

RGAPM_0

APXXA

Offline

APXXB

Online (Only on C/2)

PMC860
Group
an example printout.

Status
Partially Online

This
is just

19. Execute the bat file to resolve the issues for msi popup and GMT (TR
HK22550)
F:\Temp>avirbin_fix.bat
Note: Check for the string Error Level: -5 in the result printout.
If error level is -5, then the installation is success, if any other error level the
installation has failed.
RESULT:

1/25/2009 3:30:17 PM >


_________________________________________________________
_____
1/25/2009 3:30:17 PM > INFO -- Installing
setcagmtscheduletime

39

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

40 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

1/25/2009 3:30:18 PM
for node AP33A...
1/25/2009 3:30:18 PM
AP33A are:2
1/25/2009 3:30:18 PM
for node AP33B...
1/25/2009 3:30:19 PM
AP33B are:4
1/25/2009 3:30:19 PM
1/25/2009 3:30:19 PM
1/25/2009 3:30:19 PM
1/25/2009 3:30:19 PM
execution: START...

>

INFO -- Counting resource groups

>

INFO -- Resource groups for node

>

INFO -- Counting resource groups

>

INFO -- Resource groups for node

>
>
>
>

INFO
INFO
INFO
INFO

It is continued further with


end.
1/25/2009

Reference

3:30:19 PM >

Node Name is: AP33A


Active Node is: AP33B
Executing object flow...
Starting object

the following line in the

INFO -- Error Level: -5

20. Activate node-A


C:\>fcractivate
RESULT:

Are you sure that you want to execute command '


fcractivate '?
[y(es)/n(o)]:yes
Note: A failover of resources is done and the upgraded node-A becomes
active.
21. Check the fcrstate again
C:\>fcrstate
RESULT:

Activating
Note : Check for the state at intervals of 3 min. until the state becomes
Activated
22. Check the fcrstate again
C:\>fcrstate
RESULT:

Activated
Note: If the state is activated then continue with step 23 else wait for some
time and then repeat the step. Even then the state Activated is not reached
after 40 min, then a FCR restore is required. Follow OPI for Ref [5] AP,
Function Change Reference Package, Manual Restore
Non-updated passive node-B

40

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

41 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

23. Logon to the non-updated node


Verify that the node is passive
F:\TEMP>prcstate
RESULT:

Passive
Verify that all cluster resources are online
F:\TEMP>cluster group
RESULT:

Group

Node

Disk Group

APXXA

RGAPM_1

APXXB

Online

Cluster
Group

APXXA

Online

RGAPM_0

APXXA

Online

APXXA

Online (Only on
C/2)

PMC860
Group

Status
Partially
Online

This is just an example printout.


24. Continue the FCR session on the current passive node-B
C:\>fcrcontinue
RESULT:

Are you sure that you want to execute command fcrcontinue '?
[y(es)/n(o)]:yes
Answer with yes to continue fcr session.
The procedure installs all CXCs including anti-virus on the node. The
installation takes approximately 10 minutes. After the installation a reboot is
initiated.
Note:Wait for 5 min after reboot to login.

Passive B Node

41

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

42 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

25. Check the fcrstate .


C:\>fcrstate
RESULT:

Continued or Continuing
If the state is continued goto step 30. If the state is continuing even after 30
minutes continue with step 26.
26. Check the hostname
C:\>hostname
RESULT:
APXXB
27. Disable and enable the replication for this host. Use hostname checked at the
previous step
C:\>cd /d "C:\program files\force\frconfig\domainrename"
C:\program files\force\frconfig\domainrename>repadmin
/options <hostname> +DISABLE_INBOUND_REPL +
DISABLE_OUTBOUND_REPL
C:\ program files\force\frconfig\domainrename>repadmin
/options <hostname> -DISABLE_INBOUND_REPL
-DISABLE_OUTBOUND_REPL
RESULT:
Current DC Options: IS_GC DISABLE_INBOUND_REPL
DISABLE_OUTBOUND_REPL
New DC Options: IS_GC
28. Force replication.
C:\program files\force\frconfig\domainrename>repadmin
/syncall /A <A-node hostname>
RESULT:
Syncing all NC's held on AP33A.
Syncing partition: DC=ForestDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int

42

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

43 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=DomainDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition:
CN=Schema,CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int

43

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

44 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

CALLBACK MESSAGE: The following replication completed


successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
To : 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Note: This is an example printout.
C:\program files\force\frconfig\domainrename>repadmin
/syncall /A <B-node hostname>
RESULT:
Syncing all NC's held on AP33B.
Syncing partition: DC=DomainDnsZones,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=ForestDnsZones,DC=ap33dom,DC=int

44

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

45 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

CALLBACK MESSAGE: The following replication is in


progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition:
CN=Schema,CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: CN=Configuration,DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
Syncing partition: DC=ap33dom,DC=int
CALLBACK MESSAGE: The following replication is in
progress:

45

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

46 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: The following replication completed
successfully:
From: 80077248-9cad-4fc3-8481065c95bc5ad1._msdcs.ap33dom.int
To : 56561609-faba-480f-83586910828a96f9._msdcs.ap33dom.int
CALLBACK MESSAGE: SyncAll Finished.
SyncAll terminated with no errors.
29. Check the fcrstate .
C:\>fcrstate
RESULT:

Continued
If the state is not Continued then wait for some time and again repeat step
29 till state Continued is reached. Even then if the state is not reached after
40 min then a FCR restore is required. Follow OPI for Ref [5] AP, Function
Change Reference Package, Manual Restore
30. Print the cluster group.
C:\>cluster group
RESULT:

Group

Node

Disk Group

APXXA

RGAPM_1

APXXB

Offline

Cluster
Group

APXXA

Online

RGAPM_0

APXXA

Online

APXXA

Online (Only on C/2)

PMC860
Group

Status
Partially Online

46

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

47 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

This is just an example printout.


31. Execute the bat file to resolve the issues for msi popup and GMT (TR
HK22550)
F:\Temp>avirbin_fix.bat
Note: Check for the string Error Level: -5 in the result printout.
If error level is -5, then the installation is success, if any other error level the
installation has failed.

RESULT:

1/25/2009 3:30:17 PM >


_________________________________________________________
_____
1/25/2009 3:30:17 PM > INFO -- Installing
setcagmtscheduletime
1/25/2009 3:30:18 PM > INFO -- Counting resource groups
for node AP33A...
1/25/2009 3:30:18 PM > INFO -- Resource groups for node
AP33A are:2
1/25/2009 3:30:18 PM > INFO -- Counting resource groups
for node AP33B...
1/25/2009 3:30:19 PM > INFO -- Resource groups for node
AP33B are:4
1/25/2009 3:30:19 PM > INFO - Node Name is: AP33A
1/25/2009 3:30:19 PM > INFO - Active Node is: AP33B
1/25/2009 3:30:19 PM > INFO - Executing object flow...
1/25/2009 3:30:19 PM > INFO - Starting object
execution: START...
It is continued further with
end.
1/25/2009

3:30:19 PM >

the following line in the

INFO -- Error Level: -5

32. End fcr procedure


C:\>fcrend
RESULT:

Are you sure that you want to execute command 'fcrend '?
[y(es)/n(o)]:yes

47

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

48 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Answer with yes to continue fcr session.


33. Wait until fcrstate is noFCR.
C:\>fcrstate
RESULT:

noFCR
34.Put diskeeper resource online
F:\temp>cluster res diskeeper

/on /wait

35. Print the cluster group.


C:\>cluster group
RESULT:

Group

Node

Disk Group

APXXA

RGAPM_1

APXXB

Online

Cluster
Group

APXXA

Online

RGAPM_0

APXXA

Online

APXXA

Online (Only on C/2)

PMC860
Group

Status
Online

This is just an example printout

Both Nodes
36. Delete the dummy user created for fcr

48

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

49 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

F:\temp>fcr_delete_user.vbs
RESULT:

user deleted :<user name>


or
Prompt is returned
Note: Ignore the following error related to an account name
37. Synchronize the nodes time with cluster time
F:\TEMP>net time \\192.168.169.33 /SET /y
RESULT:

Current time at \\192.168.169.33 is 10/1/2008 6:52 PM


The command completed successfully.
Note: This is an example printout
38. Workaround for TR HJ56640 copy back the SSH hostkey
F:\TEMP>restore_hostkey.bat
RESULT:

1 file(s) copied.
1 file(s) copied.
Verify the execution of the command
F:\temp>echo %errorlevel%
The result should be 0.
39. Restore the old apg40.inf file
F:\TEMP>apg40_inf_restore.bat
RESULT:

1 file(s) copied.
Verify the execution of the command
F:\temp>echo %errorlevel%
The result should be 0.
40. Restore the inodist.ini file
F:\TEMP>copy F:\temp\inodist.ini C:\acs\data\AVIR /Y
RESULT:

1 file(s) copied

49

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

50 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

41. Restore the Anti-Virus proxy settings


F:\TEMP>copy \\clustername\G$\fcr_upgrade\root\acs\data\
FCH\current\CXC1371268\eTrustRestoreProxy.bat C:\Temp
RESULT:

1 file(s) copied
F:\TEMP>copy \\clustername\G$\fcr_upgrade\root\acs\data\
FCH\current\CXC1371268\eTrustRestoreProxy.vbs C:\Temp
RESULT:

1 file(s) copied
F:\TEMP>C:\Temp\eTrustRestoreProxy.bat
RESULT:

Prompt is returned
42. Get the date, time & localtimezones simultaneously on both nodes with the
following commands and ensure that the output is same on both nodes before
starting installation.
F:\TEMP>time /t && date /t
F:\TEMP>ChangeTZ c
If the time or date or localtimezones are different on both nodes then
execute step 43 on passive node or continue with step 45 on passive node
Passive node
43. Logon to the node.Verify that the node is passive
F:\TEMP>prcstate
RESULT:

Passive
44. To change the time use the following command (In accordance with active
node)
F:\TEMP>time
To change the date use the following command
F:\TEMP>date

50

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

51 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

To change the localtimezone use the following commands:


F:\TEMP>ChangeTZ -l
This command will list the available timezones with
indexnumber for each timezone. Note the index number of
the required timezone.
F:\TEMP>ChangeTZ -s indexnumber
Replace the index number with the one noted above.
This command will change the localtimezone to the required one
45. Logon to the node.Verify that the node is passive Verify that all cluster
resources are online.
F:\TEMP>prcstate
RESULT:

Passive
F:\TEMP>cluster group
RESULT:

Group

Node

Disk Group

APXXA

RGAPM_1

APXXB

Online

Cluster
Group

APXXA

Online

RGAPM_0

APXXA

Online

APXXA

Online (Only on C/2)

PMC860
Group

Status
Online

This is just an example printout.


Note:Check for the timezone assosciatation on the active before
proceeding for LBB installation.(mtzln p)

51

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

52 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

46. Installation of e31


Install the hotfix on the passive node:
F:\TEMP>F:\temp\APG40\LBB\hfx_e31\hfx_e31.bat
Note: The installation will approximately take 1 minute on C/2 and C/4
RESULT:

The following printout shall then be received as the last


line:
"SUCCESS -- hfx_e31 - Hotfix successfully applied!"
The hotfix is then installed.
Note: It's possible in a script to check whether the installation was
successful by checking the return code in the following way:
F:\TEMP>echo %errorlevel%
If 0, the first step installation was successful.
If -5, the installation was success and reboot not required
If -2, not applicable.
If -3, nothing to fix.
If -4, already installed.
If other values then installation failed.
47. Installation of e28
Install the hotfix e28 on the passive node:
F:\TEMP>F:\Temp\APG40\LBB\hfx_e28\hfx_e28.bat
Note: The installation will approximately take 1 minute on C/2 and C/4
RESULT:

The following printout shall then be received as the last


line:
"SUCCESS -- hfx_e28 - Hotfix successfully applied!"
Note: It's possible in a script to check whether the installation was
successful by checking the return code in the following way:
F:\TEMP>echo %errorlevel%
If 0, the installation was successful
if -5, the installation was success and reboot not required
if -4 the CNI was already
installed
if -3, there is nothing to fix,
if -2 then this fix is not applicable on the system.
If other value than 0, -5, -4,-2 or -3 ,the installation failed.
48. Check the status of the schedule service (TR HK32489)

52

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

53 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

F:\temp>fchstate -q Schedule
Result:
F:\temp>fchstate -q Schedule
Schedule DISABLED : Stopped
Enable and Start the Schedule Service
F:\temp>sc config Schedule start= Demand
F:\temp>net start Schedule
Result:
F:\temp>net start Schedule
The Schedule service is starting.
The Schedule service was started successfully.
F:\temp>sc config Schedule start= demand
[SC] ChangeServiceConfig SUCCESS
Check the status of the schedule service
F:\temp>fchstate -q Schedule
Result:
F:\temp>fchstate -q Schedule
Schedule DEMAND START : Running
If the schedule service is not started continue with the next command else
goto step 49
F:\temp>shutdown /R /F /T 1
Result:
REBOOT INITIATED!
Wait approximately 5 minutes from the time of reboot.
After the node is up and running start the schedule service
F:\temp>net start Schedule
Result:
F:\temp>net start Schedule
The Schedule service is starting.
The Schedule service was started successfully.
Check the status of the schedule service

53

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

54 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

F:\temp>fchstate -q Schedule
Result:
F:\temp>fchstate -q Schedule
Schedule Manual : Started
49. Stop & Disable the services ACS_PRC_ClusterControl and
ACS_FCH_Server
It must be peformed in the following order:
F:\temp>net stop ACS_PRC_Clustercontrol
F:\temp>sc config ACS_PRC_Clustercontrol start= disabled
F:\temp>net stop ACS_FCH_Server
F:\temp>sc config ACS_FCH_Server start= disabled
This step stops and changes Startup to Disabled for the following
services:
ACS_FCH_Server and ACS_PRC_ClusterControl
Wait for the following printouts (it takes some seconds) for all the services
before continuing with the step 50
RESULT:

F:\temp>net stop ACS_PRC_Clustercontrol


The ACS_PRC_ClusterControl service is stopping.
The ACS_PRC_ClusterControl service was stopped
successfully.
F:\temp>sc config ACS_PRC_Clustercontrol start= disabled
[SC] ChangeServiceConfig SUCCESS
F:\temp>net stop ACS_FCH_Server
The ACS_FCH_Server service is stopping.
The ACS_FCH_Server service was stopped successfully.
F:\temp>sc config ACS_FCH_Server start= disabled
[SC] ChangeServiceConfig SUCCESS
50. Confirm the above services have stopped and are disabled, use the
following commands:
F:\temp>fchstate -q ACS_PRC_clustercontrol
F:\temp>fchstate -q ACS_FCH_server
If the above services are either running or not disabled, then repeat
steps 49 & 50, till the status is reached and continue with step 51
RESULT:

F:\temp>fchstate -q ACS_PRC_clustercontrol

54

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

55 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

ACS_PRC_clustercontrol DISABLED : Stopped


F:\temp>fchstate -q ACS_FCH_server
ACS_FCH_server DISABLED : Stopped
51. Install hotfix P4.1 on passive node:
F:\TEMP>F:\Temp\APG40\LBB\hfx_p41\hfx_p41.bat
Note: The installation approximately takes 5 minutes on C/2 and 3 minutes
on C/4
The following printout shall then be received as the last
line:
"hfx_p41 hotfix successfully applied!".
The hotfix is then installed.
Note: It's possible in a script to check whether the installation was
successful by checking the return code in the following way:
F:\TEMP>echo %errorlevel%
If 0, the first step installation was successful.
If -5, the installation was success and reboot not required
If -2, not applicable.
If -3, nothing to fix.
If -4, already installed.
If other values then installation failed.
52. Check whether the H/W is APG40 C/2 or C/4
F:\TEMP>hwver
RESULT:

AP HARDWARE VERSION
APG40C/4 or APG40C/2
If APG40C/2 continue with step 53, otherwise if APG40C/4 goto step 55
53. Installation of R3.11
F:\TEMP>F:\Temp\APG40\LBB\hfx_r311\hfx_r311.bat
Note: The installation will approximately takes 1 minute on C/2
RESULT:

The following printout shall then be received as the last


line:
"hfx_r311 hotfix successfully applied!"
The hotfix is then installed.
Note: It's possible in a script to check whether the installation was
successful by checking the return code in the following way:
F:\TEMP>echo %errorlevel%
If 0, the first step installation was successful.

55

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

56 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

If -5, the installation was success and reboot not required


If -2, not applicable.
If -3, nothing to fix.
If -4, already installed.
If other values then installation failed.
54. Installation of R3.10
F:\TEMP>F:\Temp\APG40\LBB\hfx_r310\hfx_r310.bat
Note: The installation approximately takes 1 minute on C/2
RESULT:

The following printout shall then be received as the last


line:
"hfx_r310 hotfix successfully applied!"
The hotfix is then installed.
Note: It's possible in a script to check whether the installation was
successful by checking the return code in the following way:
F:\TEMP>echo %errorlevel%
If 0, the installation was successful
if -5, the installation was success and reboot not required
if -4 the CNI was already installed
if -3, there is nothing to fix.
If other value than 0, -5, -4 or -3, the installation failed
55. Check whether the H/W is APG40 C/2 or C/4
C:\temp>hwver
AP HARDWARE VERSION
APG40C/4 or APG40C/2
If APG40C/2 then goto step 57 otherwise if APG40C/4 continue with step 56
56. Installation of R3.13
F:\TEMP>F:\Temp\APG40\LBB\hfx_r313\hfx_r313.bat
Note: The installation approximately takes 2 minutes on C/4
RESULT:

The following printout shall then be received as the last


line:
"hfx_r313 hotfix successfully applied!"
The hotfix is then installed.
Note: It's possible in a script to check whether the installation was
successful by checking the return code in the following way:
F:\TEMP>echo %errorlevel%

56

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

57 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

If 0, the installation was successful


if -5, the installation was success and reboot not required,
if -4 the CNI was already installed
if -3, there is nothing to fix.
If other value than 0, -5, -4 or -3, the installation failed
57. Installation of R3.18
F:\TEMP>F:\Temp\APG40\LBB\hfx_r318\hfx_r318.bat
Note: The installation approximately takes 2 minutes on both C/2 and C/4
RESULT:

The following printout shall then be received as the last line:


"hfx_r318 hotfix successfully applied!"
The hotfix is then installed.
Note: It's possible in a script to check whether the installation was
successful by checking the return code in the following way:
F:\TEMP>echo %errorlevel%
If 0, the installation was successful
If -5, the installation was success and reboot not required
If -4 the CNI was already installed
If -3, there is nothing to fix.
If other value than 0, -5, -4 or -3, the installation failed
58. Installation of R3.17
F:\TEMP>F:\Temp\APG40\LBB\hfx_r317\hfx_r317.bat
Note: The installation approximately takes 1 minute on both C/2 and C/4.
RESULT:
The following printout shall then be received as the last
line:
"hfx_r317 hotfix successfully applied!"
The hotfix is then installed.
Note: It's possible in a script to check whether the installation was
successful by checking the return code in the following way:
F:\TEMP>echo %errorlevel%
If 0, the first step installation was successful.
If -5, the installation was success and reboot not required
If -2, not applicable.
If -3, nothing to fix.
If -4, already installed.
If other values then installation failed.

57

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

58 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

59. Disable and stop the services inort, inorpc,inotask, diskeeper


F:\temp>sc config inort start= disabled
[SC] ChangeServiceConfig SUCCESS
F:\temp>sc config inorpc start= disabled
[SC] ChangeServiceConfig SUCCESS
F:\temp>sc config inotask start= disabled
[SC] ChangeServiceConfig SUCCESS
F:\temp>sc config diskeeper start= disabled
[SC] ChangeServiceConfig SUCCESS
F:\temp>net stop inort
The eTrust Antivirus Realtime Server service is
stopping....
The eTrust Antivirus Realtime Server service was stopped
successfully.
F:\temp>net stop inorpc
The eTrust Antivirus RPC Server service is stopping.
The eTrust Antivirus RPC Server service was stopped
successfully.
F:\temp>net stop inotask
The eTrust Antivirus Job Server service is stopping...
The eTrust Antivirus Job Server service was stopped
successfully.
F:\temp>net stop diskeeper
The Diskeeper service was stopped successfully.
Verify if the above services are disable and stopped
60. Check the services are in stopped and disbaled state
F:\temp>fchstate -q inort
inort DISABLED : Stopped
F:\temp>fchstate -q inorpc
inorpc DISABLED : Stopped
F:\temp>fchstate -q inotask
inotask DISABLED : Stopped
F:\temp>fchstate -q diskeeper
diskeeper DISABLED : Stopped

58

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

59 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

61. Install the hotfix hfx_e33 on the passive node


F:\TEMP>F:\Temp\APG40\LBB\hfx_e33\hfx_e33.bat
Note: The installation approximately takes 20 minutes on C/2 and 10
minutes on C/4.
RESULT:

The following printout shall then be received as the last


line:
"hfx_e33 hotfix successfully applied"
The security patch is then installed.
Note: It's possible in a script to check whether the installation was
successful by checking the return code in the following way:
F:\TEMP>echo %errorlevel%
If 0, the installation was successful
if -5, the installation was success and reboot not required
if -4 the CNI was already installed
if -3, there is nothing to fix.
If other value than 0, -5, -4 or -3, the installation failed
62. Reboot the node manually
F:\TEMP>prcboot f
RESULT:

REBOOT INITIATED!
Wait approximately 5 minutes from the time of reboot.
63. Verify that the node is the Passive node
F:\TEMP>prcstate
RESULT:

Passive
64. This step has to be performed only if the error level received at step 61 is 0.
If error level received at step 61 is other than 0, the behaviour is specified at
step 61 already
Verify that the security level is S6.2.5.
F:\TEMP>swrprint| findstr /c:"Force Security Patch: 6.2.5"
65. Check the errorlevel
F:\TEMP>echo %errorlevel%
If 0, continue with step 66
If other value than 0, and it is the first time that security level 6.2.5 is
checked then go to step 59
If other value than 0, and it not the first time that security level 6.2.5 is
checked then installation of hfx_e33 failed

59

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

60 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

66. Verify that all cluster resources are online


F:\TEMP>cluster group
RESULT:

Group

Node

Disk Group

APXXA

RGAPM_1

APXXB

Online

Cluster
Group

APXXA

Online

RGAPM_0

APXXA

Online

APXXA

Online (Only on C/2)

PMC860
Group

Status
Online

67. Check the contents of the created log files of hfx_p41, hfx_r311, hfx_r310,
hfx_r313, hfx_r318, hfx_r317 and hfx_e33.
F:\TEMP>type F:\Temp\APG40\LBB\hfx_p41\hfx_p41.log
The following line shall be received at the end of the log file.
"hfx_p41 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP>type F:\Temp\APG40\LBB\hfx_r311\hfx_r311.log
Note: Run the above command on only APG40 C/2
The following line shall be received at the end of the log file.
"hfx_r311 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP>type F:\Temp\APG40\LBB\hfx_r310\hfx_r310.log
Note: Run the above command on only APG40 C/2
The following line shall be received at the end of the log file.
"hfx_r310 hotfix successfully applied!"
After the above line checksum information will be displayed

60

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

61 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

F:\TEMP>type F:\Temp\APG40\LBB\hfx_r313\hfx_r313.log
Note: Run the above command on only APG40 C/4
The following line shall be received at the end of the log file.
"hfx_r313 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP>type F:\Temp\APG40\LBB\hfx_r318\hfx_r318.log
The following line shall be received at the end of the log file.
"hfx_r318 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP> type F:\Temp\APG40\LBB\hfx_r317\hfx_r317.log
The following line shall be received at the end of the log file.
"hfx_r317 hotfix successfully applied!"
After the above line checksum information will be displayed
F:\TEMP>type F:\Temp\APG40\LBB\hfx_e33\hfx_e33.log
The following lines shall be received at the end of the log file.
INFO -- hfx_e33 Hotfix successfully applied
INFO -- hfx_e33 Please Reboot the machine in order to apply the changes
INFO -- Error Level: 0
68. Remove the LBB folder from F:\Temp in order to get free space on F:\
F:\TEMP>rd /S /Q F:\TEMP\APG40\LBB
RESULT:

Prompt is returned
69. Change the startup type for diskeeper
F:\temp>sc config diskeeper start= Demand
Active node
70. Logon to the node
Verify that the node is Active
F:\TEMP>prcstate
RESULT:

Active
Verify that all cluster resources are online
F:\TEMP>cluster group
RESULT:

61

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

62 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Group

Node

Disk Group

APXXA

RGAPM_1

APXXB

Online

Cluster
Group

APXXA

Online

RGAPM_0

APXXA

Online

APXXA

Online (Only on C/2)

PMC860
Group

Status
Online

71. Perform failover


F:\TEMP>prcboot f
RESULT:

REBOOT INITIATED!
Wait approximately 7 minutes from the time of reboot.
Passive node
72. Logon to the node
Verify that the node is the passive node
F:\TEMP>prcstate
RESULT:

Passive
Verify that all cluster resources are online
F:\TEMP>cluster group
RESULT:

62

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

63 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Group

Node

Disk Group

APXXB

RGAPM_1

APXXB

Online

Cluster
Group

APXXB

Online

RGAPM_0

APXXA

Online

APXXB

Online (Only on C/2)

PMC860
Group

Status
Online

73. Repeat steps 45 69 on this passive node then continue with step 74
Active Node
74. Logon to the node
Verify that the node is the Active node
F:\TEMP>prcstate
RESULT:

Active
Verify that all cluster resources are online
F:\TEMP>cluster group

RESULT:

63

Ericssonwide Internal
64 (80)

INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

75.

Reference

Group

Node

Disk Group

APXXB

RGAPM_1

APXXB

Online

Cluster
Group

APXXB

Online

RGAPM_0

APXXA

Online

APXXB

Online (Only on C/2)

PMC860
Group

Status
Online

Get

the localtimezone with the following command.


F:\TEMP>ChangeTZ c
Note 1: It is upto the user to manually change to the desired time zone after
installation.
Note 2: Caucasus Standard Time:
Changes display name to Caucasus Standard Time as cities in the previous
display name have separate time zones, and removes DST settings.
If the localtimezone of a particular APG40 has to be changed, use the
following commands (if that particular country falls under a newtimezone or if
its local timezone changed recently).
F:\TEMP>ChangeTZ -l
This command will list the available timezones with indexnumber for each
timezone.Note the index number of the required timezone.
F:\TEMP>ChangeTZ -s indexnumber
Replace the index number with the one noted above. This command will
change the localtimezone to the required one
F:\TEMP>ChangeTZ -c
This command will display the localtimezone.
76. If the localtimezone of a particular APG40 has been changed or
If the timezone association with CP is missing
then, use the following commands on the active node to change or
recreate the association with CP else go to step 77

64

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

65 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

F:\TEMP>mtzln -p
This command will list the current timezone association with CP.
Note the association number from the printout.(If the association is already
lost, then note the association number as 0)
If mtzln p reports null or if mtzln p output does not match with
ChangeTZ c from step 75, continue with following steps else proceed with
step 77. (Refer Appendix A in Chapter 7 for different TimeZones).
F:\TEMP>mtzln -r "associationnumber"
Use this command to remove the current assocaition with CP.
In the above command replace the associationnumber with the one noted in t
he above command(without quotes).If the association is found as lost in the
above command, then this command need not be executed .
F:\TEMP>tzls
This command lists the timezones in AP.Note the name
of the local timezone(of AP) from this list
F:\TEMP>mtzln -f "NewTimeZone" "associationnumber"
This comamnd will reassociate the AP localtimezone with CP.
Replace the NewTimeZone and associationnumber with
the ones noted in the above commands(without quotes).
Both Nodes
77. Execute the nsf script to update the registry information for NSFBIN
F:\temp\>cd Script_1289
F:\temp\Script_1289>install.bat

RESULT:
-------------------------------------------------------.
CNI 109 22-APZ 212 30/4-1289
.
09.2008
-------------------------------------------------------Script execution starts to perform adding registry for
CNI-APZ21230/4-1289
Info --- Shell Object created successfully. RESULT CODE
[0]
Info --- Registry successfully read from
HKLM\SYSTEM\CurrentControlSet\Control\Session
Manager\BootExecute RESULT CODE [0]
reg add "HKLM\System\CurrentControlSet\Control\Session
Manager" /v BootExecute /t REG_MULTI_SZ /d "autocheck
autochk /k:GJKLMQRSVY *"\0"autocheck
burStartup"\0"autocheck
C:\WINNT\System32\biostimerecovery.exe" /f

65

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

66 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Info --- Registry successfully updated to


HKLM\SYSTEM\CurrentControlSet\Control\Session
Manager\BootExecute RESULT CODE [0]
________________________________________________
Info -- Success -- "Script Executed successfully"
_______________________________________________
F:\temp\Script_1289>cd..
Active node
78. Execute the command to start the Network Survilience function
F:\temp>nsfstart
RESULT:
Network surveillance started
79. Check whether the H/W is APG40 C/2 or C/4
F:\temp>hwver
RESULT:

AP HARDWARE VERSION
APG40C/4 or APG40C/2
If APG40C/2 goto step 81, otherwise if APG40C/4 goto step 80
80. Enable smart data collection on C/4
F:\temp>c:
C:\>cd Progra~1\force\tools
C:\progra~1\force\tools>frlbbdiag -i
RESULT:

[
[
[
[
[
[
[
[
[
[
[
[
[
[
[
[
[
[
[

INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO

]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]

frlbbdiag.exe 1.0.0.4
Emerson Network Power GmbH
Copyright (C) 2008 Emerson Network Power GmbH
Platform 8.1.4
Frlbbdiag tool running on node AP33A
enabling SMART on d0b0t0d0
-- done.
enabling SMART on d0b0t1d0
-- done.
enabling SMART on d0b0t2d0
-- done.
enabling SMART on d0b1t0d0
-- done.
enabling SMART on d0b1t1d0
-- done.
enabling SMART on d0b1t2d0
-- done.
Ignoring all log data older than 30 day(s)!
Start analyzing physical disk[0] = d0b0t0d0

66

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

67 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

[
[
[
[
[
[
[
[

INFO
INFO
INFO
INFO
INFO
INFO
- - NOTE
NOTE

]
]
]
]
]
]
]
]

Reference

Start analyzing physical disk[1] = d0b1t0d0


Start analyzing physical disk[2] = d0b0t1d0
Start analyzing physical disk[3] = d0b1t1d0
Start analyzing physical disk[4] = d0b0t2d0
Start analyzing physical disk[5] = d0b1t2d0
- - - - - - - - - - - -Summary Report- - - - No failed disks found on both nodes!
A recommendation cannot be made!

Both nodes
81. Copy the IPNA files in tftpboot folder (HK29160)
F:\temp>copy C:\Program
Files\AP\OCS\Conf\boot.ipnx.not_loading
C:\tftpboot\boot.ipn2 /Y
RESULT:
1 file(s) copied.

F:\temp>copy C:\Program
Files\AP\OCS\Conf\boot.ipnx.not_loading
C:\tftpboot\boot.ipn3 /Y
RESULT:
1 file(s) copied.

82. Execute the step to enable the APBACKUPUSRG to take backup (TR
HK28733)
F:\temp>C:\Program
Files\AP\ACS\BIN\runburserverdcomperm.bat
Result:
Successfully set the Application Launch ACL
83. Confirm the Etrust services are in automatic state and started, use the
following commands
F:\temp>fchstate q InoTask
F:\temp>fchstate -q InoRPC
F:\temp>fchstate -q InoRT
RESULT:

InoTask AUTO START : Running


InoRPC AUTO START : Running
InoRT AUTO START : Running

67

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

68 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

If the above services are automatic and running then go to step88 else
continue with step 84.
84. Confirm that the antivirus path is updated.
F:\temp>PATH
RESULT:

Note: Check for the following string in result printout.


_C:\Program Files\AP\STS\lib;C:\PROGRA~1\FSecure\ssh;C:\ProgramFiles\CA\SharedComponents\ScanEngine
;C:\Program
Files\CA\SharedComponents\CAUpdate\;C:\Program
Files\CA\SharedComponents\ThirdParty\;C:\Program
Files\CA\SharedComponents\SubscriptionLicense\;C:\Program
Files\CA\eTrustITM;;C:\Program Files\AP\APOS\Team;c:\
If the above mentioned string exists in the path variable then go to step 85
else continue with step 84
85. Execute the Vb script to update the antivirus path
F:\temp>AVIRPATH_check_on_C.vbs
RESULT:
_Note: Check for the following string in result printout
_Script execution starts to perform modification of Path

environment variable for antivirus CA 8.1


path after write for ControlSet001:
C:\Program
Files\CA\SharedComponents\ScanEngine;C:\Program
Files\CA\SharedComponents\CAUpdate\;C:\Program
Files\CA\SharedComponents\ThirdParty\;C:\Program
Files\CA\SharedComponents\SubscriptionLicense\;C:\Program
Files\CA\eTrustITM;
path after write for ControlSet003:
C:\Program
Files\CA\SharedComponents\ScanEngine;C:\Program
Files\CA\SharedComponents\CAUpdate\;C:\Program
Files\CA\SharedComponents\ThirdParty\;C:\Program
Files\CA\SharedCompo
nents\SubscriptionLicense\;C:\Program Files\CA\eTrustITM;
Note: The string path after write for ControlSet00X: in the above printout

68

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

69 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

can have any value for X depending of the number of ControlSet on the
registry of the target system.
86. Start the eTrust Services on the node
F:\temp>sc config InoTask start= Auto
RESULT: [SC] ChangeServiceConfig SUCCESS

F:\temp>net start InoTask


RESULT:

The eTrust ITM Job Service service is starting.


The eTrust ITM Job Service service was started
successfully.
F:\temp>sc config InoRPC start= Auto
RESULT: [SC] ChangeServiceConfig SUCCESS
F:\temp>net start InoRPC
RESULT:

The eTrust ITM RPC Service service is starting.


The eTrust ITM RPC Service service was started
successfully.

F:\temp>sc config InoRT start= Auto


RESULT: [SC] ChangeServiceConfig SUCCESS
F:\temp>net start InoRT
RESULT:

The eTrust Antivirus Realtime Server service is starting.


The eTrust Antivirus Realtime Server service was started
successfully.
87. Confirm that the above Etrust services are in automatic state and
started, use the following commands:
F:\temp>fchstate q InoTask
F:\temp>fchstate -q InoRPC
F:\temp>fchstate -q InoRT
RESULT:

InoTask AUTO START : Running


InoRPC AUTO START : Running
InoRT AUTO START : Running

69

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

70 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

88. Start and check the diskeeper service on the node


F:\temp>net start diskeeper
RESULT:

The diskeeper Service service is starting.


The diskeeper Service service was started successfully
F:\temp>fchstate -q diskeeper
RESULT:

diskeeper Demand START : Running

5.10

Update software product identification

Both nodes
Execute the product update installation script
F:\TEMP>swrprod_agm019_AP1.bat
RESULT:

swrprod: The third party product 'LBBCNI CRZ 222 05 ' is


saved.
swrprod: The third party product 'APM 5.0.5 5/LZY242113/1
R1F' is removed.
swrprod: The third party product 'APIO 4.0.4
5/LZY242113/2 R1E' is removed.
swrprod: The third party product 'APM 5.0.6 5/LZY242113/1
R1G' is saved.
swrprod: The third party product 'APIO 4.0.5
5/LZY242113/2 R1F' is saved.
swrprod: The third party product 'AGM 018 R1C' is
removed.
swrprod: The third party product 'AGM 019 R1E' is saved.
swrprod: The third party product 'IAM ' is removed.
swrprod: The third party product 'IAM ' is saved.
Update system identity
swrsid: The new system name is APG40 One Track AGM019 AP1
E..
"Done!"

5.11

Take VLAN Backup


Note: Perform this step on any one of the nodes
Check if VLAN is defined on the node
C:>vlanls
Note: If you get any enteries in the VLAN Table, execute the next commands
to take VLAN backups of both the nodes.

70

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

71 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

C:>vlanbackup <nodeA>
C:>vlanbackup <nodeB>
where nodename is the name of the node

5.12

Set back idle timeout

Both nodes
Update with SSH application
Note! This step should only be done if connected to AP using SSH protocol.
Save original configuration file on C:\ drive from F:\ drive:
C:\>copy "F:\temp\sshd2_config" "C:\Program Files\FSecure\SSH Server\sshd2_config" /Y
RESULT:

To apply the new settings for idle timeout a new session must be started, log
out and then log in again.
Update with Telnet application
Note! This step should only be done if connected to the AP through Telnet
protocol.
Restore the original timeout value for Pragma Telnet
F:\temp\>exteldec.bat
To apply the new settings for idle timeout a new session must be started, log
out and then log in again.

5.13

Include Etrust services in the PRC Monitoring and Enable


Automatic Backup

Both nodes
Copy the par file in the C:\temp
F:\Temp>xcopy F:\temp\CXC1371268.par C:\temp
RESULT:
1 file(s) copied.

71

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

72 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Active node
Execute Soft function change to enable automatic backup and include Etrust
services in PRC monitoring..
C:\Temp>sfcstate
RESULT:

No soft function change session is in progress.


C:\Temp >sfcexec
RESULT:

Soft Function Change Session


NOTE: The session can be aborted at any time before
switch to the new system has been ordered. Press Ctrl+C
and ENTER to abort.
Would you like to copy parameter files from disk?
[y(es)/n(o)]:y
Choose one of the packages to copy parameter file into:
NO
CXCNUMBER
MODULENAME
REVISION
CNI
1
CXC1371062 BURBIN
R6C
APZ21230/4-1299
2
CXC1371096 RTRBIN
R4J
APZ21230/4-1145
3
CXC1371147 APCONFBIN
R1D
APZ21230/4-1165
4
CXC1371268 AVIRBIN
R1A
5
CXC137440
ACABIN
R6D
APZ21230/4-1082
6
CXC1371084 CDHBIN
R6B
APZ21230/4-1345
7
CXC1371087 DBOBIN
R1D
APZ21230/4-1153
8
CXC1371088 GCCBIN
R1C
APZ21230/4-1174
9
CXC1371094 SSHSERVBIN
R1F
APZ21230/4-1202
10
CXC1371097 CPFADMBIN
R1J
APZ21230/4-1151
11
CXC1371100 FCCAPIBIN
R1C
APZ21230/5-485
12
CXC1371057 CPTASPBIN
R5C
APZ21230/4-1000
13
CXC1371002 ALDABIN
R1E
APZ21230/4-836
14
CXC1371004 ALISADMBIN
R2E
APZ21230/4-990
15
CXC1371077 MLSMSSBIN
R2C
APZ21230/6-912
16
CXC137418
MMLAPIBIN
R5C
APZ21230/4-1306
17
CXC137425
AISAPIBIN
R3E
APZ21230/4-1315
18
CXC137429
MCCBIN
R4N
APZ21230/4-1331
19
CXC137430
MLSMMLBIN
R4AN
APZ21230/4-1340
20
CXC137431
PDSPGMBIN
R4D
APZ21230/4-1101
21
CXC137471
ADHADMBIN
R3H
APZ21230/4-1178
22
CXC137474
MLSMTSBIN
R4J
APZ21230/4-1329
23
CXC137479
ALECADMBIN
R1M
APZ21230/4-1222
24
CXC1371102 CLHADMBIN
R2D
APZ21240/3-172
25
CXC1371140 SGSBIN
R1D
APZ21230/4-1100
26
CXC1371243 STSCBIN
R1G
APZ21230/4-1313

72

Ericssonwide Internal
73 (80)

INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Enter a number for the package to copy parameter file


into or enter 'c(ontinue)' to continue soft function
change session.
Note: Select the number for AVIRBIN
:4
Enter the directory name where the parameter file is
located.
:c:\temp
Analysis of parameter files performed. No errors found.
Would you like to copy more parameter files?
[y(es)/n(o)]:n
Would you like to edit parameter files? [y(es)/n(o)]:y
Choose one of the packages to upgrade parameters in:
NO

CXCNUMBER

MODULENAME

REVISION

CNI

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

CXC1371062
CXC1371096
CXC1371147
CXC1371268
CXC137440
CXC1371084
CXC1371087
CXC1371088
CXC1371094
CXC1371097
CXC1371100
CXC1371057
CXC1371002
CXC1371004
CXC1371077
CXC137418
CXC137425
CXC137429
CXC137430
CXC137431
CXC137471
CXC137474
CXC137479
CXC1371102
CXC1371140
CXC1371243

BURBIN
RTRBIN
APCONFBIN
AVIRBIN
ACABIN
CDHBIN
DBOBIN
GCCBIN
SSHSERVBIN
CPFADMBIN
FCCAPIBIN
CPTASPBIN
ALDABIN
ALISADMBIN
MLSMSSBIN
MMLAPIBIN
AISAPIBIN
MCCBIN
MLSMMLBIN
PDSPGMBIN
ADHADMBIN
MLSMTSBIN
ALECADMBIN
CLHADMBIN
SGSBIN
STSCBIN

R6C
R4J
R1D
R1A
R6D
R6B
R1D
R1C
R1F
R1J
R1C
R5C
R1E
R2E
R2C
R5C
R3E
R4N
R4AN
R4D
R3H
R4J
R1M
R2D
R1D
R1G

APZ21230/4-1299
APZ21230/4-1145
APZ21230/4-1165
APZ21230/4-1082
APZ21230/4-1345
APZ21230/4-1153
APZ21230/4-1174
APZ21230/4-1202
APZ21230/4-1151
APZ21230/5-485
APZ21230/4-1000
APZ21230/4-836
APZ21230/4-990
APZ21230/6-912
APZ21230/4-1306
APZ21230/4-1315
APZ21230/4-1331
APZ21230/4-1340
APZ21230/4-1101
APZ21230/4-1178
APZ21230/4-1329
APZ21230/4-1222
APZ21240/3-172
APZ21230/4-1100
APZ21230/4-1313

73

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

74 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Enter a number for the package to upgrade parameters in


or enter 'c(ontinue)' to continue soft function change
session.
:1
Parsing format file ...
Parsing parameter file ...
Parameter editing session started.
:list
ACS_BUR_archive_backup
ACS_BUR_archive_bkp_freq
ACS_BUR_backup_window_min
ACS_BUR_bkp_start_hour
ACS_BUR_bkp_start_min
ACS_BUR_max_archive_bkps
ACS_BUR_system_backup
ACS_BUR_system_bkp_freq
:edit ACS_BUR_archive_backup
Category: Private
unsignedShortInt[0, 0] (0):1
:edit ACS_BUR_system_backup
Category: Private
unsignedShortInt[0, 0] (0):1
:end
Parameters updated
Exiting ...
Would you like to edit more parameter files?
[y(es)/n(o)]:n
System upgrade performed. Would you like to switch to the
new system, thereby starting the supervision period? (No
will abort and restore the system. [y(es)/n(o)]:y
Parameter tables generated. No errors found.
Change of parameter(s) succeeded, supervision period has
started.
Execute sfcend when supervision period is over.

74

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

75 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

F:\temp>sfcstate
Soft function change is in state 'Supervision'.
F:\temp>sfcfb

or sfcend

(sfcend command to go ahead with the new value and


sfcfb command to fallback to previous value)
Soft function change session has ended.
Both nodes
Execute the following commands to reflect the new parameter file changes
into PRC services list.
F:\temp>net stop acs_prc_clustercontrol
Result:
The ACS_PRC_ClusterControl service is stopping.
The ACS_PRC_ClusterControl service was stopped
successfully.
F:\temp>net start acs_prc_clustercontrol
Result:
The ACS_PRC_ClusterControl service is starting.
The ACS_PRC_ClusterControl service was started
successfully.

5.14

Remove the installation files

Both nodes
Remove installation files:
C:\>rd c:\temp /s /q
RESULT:

Prompt is returned.
C:\>md c:\temp
RESULT:

Prompt is returned.
C:\>rd f:\temp /s /q
RESULT:

75

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

76 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Prompt is returned.
C:\>md f:\temp
RESULT:

Prompt is returned.
C:\>rd /S /Q C:\$OEM$
Note: (Run only if the C:\$OEM$ folder exists)
RESULT:

Prompt is returned.
_
Active node
F:\temp>rd /S /Q G:\fcr_upgrade
RESULT:

Prompt is returned.

5.15

Update CA 8.1 Configuration


CA 8.1 requires authentication to download the signature updates from
internet, whereas for CA 7.1, signature update is independent of
authentication to connect to internet.
To configure the authentication details, refer OPI Ref[6] AP, Antivirus
Signature Update, Administrate for CA 8.1 (12/154 31-CNZ 222 89)

5.16

Compress current folder on both nodes (To be applied only on


APG40 C/2)

Both nodes
Check for the hwver version
C:\>hwver
RESULT:
AP HARDWARE VERSION

APG40C/4 or APG40C/2
If the result printout is C/2 proceed with the next command
Execute the given command to free space on C:\ drive

76

Ericssonwide Internal
77 (80)

INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

C:\>compact /C c:\ACS\data\FCH\current\*.* /s
Note: This step can be executed on both nodes simultaneously and this
takes around 5 minutes.
RESULT:
Compressing files in c:\ACS\data\FCH\current\
cxc1060053
0 :
0 = 1.0
cxc1060054
0 :
0 = 1.0
cxc1060055
0 :
0 = 1.0
cxc1060074
0 :
0 = 1.0
cxc1060087
0 :
0 = 1.0
CXC1325239
0 :
0 = 1.0
cxc1371001
0 :
0 = 1.0
cxc1371002
0 :
0 = 1.0
CXC1371004
0 :
0 = 1.0
cxc1371006
0 :
0 = 1.0
cxc1371007
0 :
0 = 1.0
cxc1371010
0 :
0 = 1.0
CXC1371016
0 :
0 = 1.0
CXC1371023
0 :
0 = 1.0
CXC1371031
0 :
0 = 1.0
CXC1371057
0 :
0 = 1.0
CXC1371059
0 :
0 = 1.0
CXC1371062
0 :
0 = 1.0
CXC1371063
0 :
0 = 1.0
CXC1371064
0 :
0 = 1.0
CXC1371065
0 :
0 = 1.0
CXC1371068
0 :
0 = 1.0
cxc1371077
0 :
0 = 1.0
CXC1371079
0 :
0 = 1.0
cxc1371080
0 :
0 = 1.0
CXC1371081
0 :
0 = 1.0
CXC1371082
0 :
0 = 1.0
CXC1371083
0 :
0 = 1.0
cxc1371084
0 :
0 = 1.0

to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK]
[OK

This is continued further..

5.17

Remove the domain admin user group after update


Check using following commands whether the user being used to do the
update belongs to the group Domain Admins
F:\TEMP>net group Domain Admins
If the user is a member of the groups mentioned above, run the following
commands to delete users from the groups
Note:For this logon should be done as administrator

77

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

78 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

F:\TEMP>net group "Domain Admins" <user name> /delete


5.18

Burbackup after installation


After installation of the pacakage full backup of the entire system should be
taken. Execute the command on one of the nodes.
C:\>Burbackup o
RESULT:

Execute burBackup with these parameters:


burbackup -o
[y=yes, n=no]?:yes
Answer with yes to continue

Security
Ericsson is advising against using insecure access protocols such as MTS,
FTP and Telnet, recommending all customers to use SFTP and SSH as
standard protocols when communicating with the APG. New APG systems
are delivered with the insecure access protocols disabled.
The system should be configured as required by the customer. A customer
requirement that insecure access protocols should be turned on should be
documented in a written statement.
The current status of the access protocols is available by following the
OPERATIONAL INSTRUCTION : 11/154 31-CNZ 222 89 Uen A
Blocking of Insecure Protocols, Verify.
The insecure access protocols are turned off by following the
OPERATIONAL INSTRUCTION 9/154 31-CNZ 222 89 Uen A Blocking of
Insecure Protocols, Initiate.
The insecure access protocols should only be turned on if the customer has
explicitly stated that. Usually this implies that the other nodes in the customer
network have insecure protocols enabled.
The insecure access protocols are turned on by following the
OPERATIONAL INSTRUCTION, 10/154 31-CNZ 222 89 Uen A
Blocking of Insecure Protocols, End. Note that it can take minutes before
the change is deployed in the whole APG.

APPENDIX A

78

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

79 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

Arabic Standard Time:


Adjusts DST start dates and end dates for the Baghdad time zone for
changes after the prior cumulative time zone update was created (August
2007).
Armenian Standard Time
Note Updates for the Caucasus time zone and the new Armenian time zone
are not included in the Windows Vista RTM hotfix package for this issue. The
Caucasus time zone and the Azerbaijan time zone have been separated since
Windows Vista RTM, and they do not require an update. Windows Vista will
receive all future updates to keep consistency in the Windows time zone
registry structure.
Australia:
Central Australia Standard Time
Australia Eastern Standard Time
Tasmania Standard Time
Adjusts DST start times and end times for these time zones so that they start
and end on the same day. This was changed after the prior cumulative time
zone update was created (August 2007).
Caucasus Standard Time
Changes display name to Caucasus Standard Time as cities in the previous
display name have separate time zones, and removes DST settings.
Egypt Standard Time:
Adjusts DST start dates and end dates for the Cairo time zone for changes
after the prior cumulative time zone update was created (August 2007).
GTB Standard Time
Corrects the display name for GTB Standard Time on Windows Server 2003
SP2 to include Bucharest.
Israel Standard Time:
Adjusts DST start and end dates for the Jerusalem time zone for changes
after the prior cumulative time zone update was created (August 2007).
Note Updates for the Jerusalem time zone are not included in the Windows
Vista package for this update. The Jerusalem time zone updates have been
available in Windows Vista since Windows Vista was originally released.
Jordan Standard Time
Adjusts DST start times, end times, and dates according to changes signed in
to law after the prior cumulative time zone update was created (February
2007).
New Zealand Standard Time
Adjusts DST start dates and end dates according to changes signed in to law
after the prior cumulative time zone update was created (February 2007).

79

Ericssonwide Internal
INSTALLATION INSTRUCTION
Prepared (also subject responsible if other)

80 (80)

No.

HY/XCS XCSGASA

019/1531-5/LZY242060/1

Approved

Checked

Date

Rev

TEI/XST B. Pappalardo

XCSSISU

2010-01-12

Reference

South America:
E. South America Standard Time
Central Brazilian Standard Time
Adjusts DST start dates and end dates for the Brasilia time zone and for the
Manaus time zone for changes after the prior cumulative time zone update
was created (August 2007).
Venezuela Standard Time:
Adds a new time zone for the Caracas time zone for changes after the prior
cumulative time zone update was created (August 2007).
Note: This time zone update occurs on December 9, 2007 at 3:00:00.

References
[1] 2/1551-5/LZY 242 060/21 Uen Software Record APG40 one track AP1
AGM018
[2] 2/1551-5/LZY 242 060/41 Uen Software Record APG40 one track AP1
AGM018
[3] 1551-5/LZY 242 060/1 Uen Reference Package for APG40 one track AP1
AGM019 for both C/2 and C/4 LBB
[4] 3/15431-CNZ 22281, APG40, Soft Function Change, Parameter, Change
[5] 2/154 31-CNZ 222 105 Uen, AP, Function Change Reference Package,
Manual Restore.
[6] 12/154 31-CNZ 222 89 Uen
AP, Antivirus Signature Update, Administrate for CA 8.1

80

You might also like