You are on page 1of 16

Technical Manual-System Parameters

U-SYS SoftX3000 SoftSwitch System

Table of Contents

Table of Contents
Chapter 2 Public Parameters....................................................................................................... 2-1
2.1 Background Description.................................................................................................... 2-1
2.1.1 Overview of Public Parameters..............................................................................2-1
2.1.2 List of Default Values.............................................................................................. 2-1
2.1.3 Modifying Public Parameters..................................................................................2-3
2.2 Parameter Description...................................................................................................... 2-3
2.2.1 P0Maximum Number of Modules........................................................................2-3
2.2.2 P1Number of FSPC CCBs..................................................................................2-3
2.2.3 P2Number of MSPC CCBs.................................................................................2-3
2.2.4 P3Average TCAP Component of Each Dialog....................................................2-4
2.2.5 P4Number of TCAP State Machines...................................................................2-4
2.2.6 P5TCAP Number of TCAP Component Buffers..................................................2-4
2.2.7 P6MAP-SSN Start DID.......................................................................................2-4
2.2.8 P7MAP-SSN End DID......................................................................................... 2-5
2.2.9 P8CAP-SSN Start DID........................................................................................2-5
2.2.10 P9CAP-SSN End DID.......................................................................................2-5
2.2.11 P10HLR Dialog ID Start....................................................................................2-5
2.2.12 P11HLR Dialog ID Stop.....................................................................................2-6
2.2.13 P12VLR Dialog ID Start....................................................................................2-6
2.2.14 P13VLR Dialog ID Stop.....................................................................................2-6
2.2.15 P14MSC Dialog ID Start...................................................................................2-6
2.2.16 P15MSC Dialog ID Stop....................................................................................2-6
2.2.17 P16................................................................................................................... 2-7
2.2.18 P17................................................................................................................... 2-7
2.2.19 P18................................................................................................................... 2-7
2.2.20 P19................................................................................................................... 2-7
2.2.21 P20................................................................................................................... 2-7
2.2.22 P21Minimum DID of INAP.................................................................................2-8
2.2.23 P22Maximum DID of INAP................................................................................2-8
2.2.24 P23Maximum SCTP ASSOC............................................................................2-8
2.2.25 P24Maximum SCTP Stream.............................................................................2-9
2.2.26 P25Maximum SCTP TWND..............................................................................2-9
2.2.27 P26Maximum SCTP RWND..............................................................................2-9
2.2.28 P27Maximum SCTP Connected Segment Number........................................2-10
2.2.29 P28................................................................................................................. 2-10
2.2.30 P29................................................................................................................. 2-10
2.2.31 P30................................................................................................................. 2-10

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Table of Contents

2.2.32 P31................................................................................................................. 2-10


2.2.33 P32.................................................................................................................. 2-11
2.2.34 P33.................................................................................................................. 2-11
2.2.35 P34.................................................................................................................. 2-11
2.2.36 P35.................................................................................................................. 2-11
2.2.37 P36.................................................................................................................. 2-11
2.2.38 P37................................................................................................................. 2-12
2.2.39 P38Maximum H323 Call CCB.........................................................................2-12
2.2.40 P39Maximum H323 RAS CCB........................................................................2-12
2.2.41 P40Maximum H323 Original Call CCB............................................................2-12
2.2.42 P41Maximum H323 Spec Code CCB.............................................................2-12
2.2.43 P42Maximum SIPSL Trunk.............................................................................2-13
2.2.44 P43Maximum HSL Trunk................................................................................2-13
2.2.45 P44Maximum V5ST........................................................................................ 2-13
2.2.46 P45................................................................................................................. 2-13
2.2.47 P46Console Message Resend Times.............................................................2-13
2.2.48 P47Console Message Resend Interval...........................................................2-14

ii

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

Chapter 2 Public Parameters


2.1 Background Description
2.1.1 Overview of Public Parameters
I. Purpose of Public Parameters
The SoftX3000 has 46 public parameters in total.

II. Relationship between Public Parameters and Other Parameters

2.1.2 List of Default Values


Table 1.1 A list of default values of public parameters
Parameter ID

Parameter name

Default value

P0

Maximum number of modules

255

P1

Number of FSPC CCBs

10000

P2

Number of MSPC CCBs

7000

P3

Average TCAP component of each

dialog
P4

Number of TCAP state machines

2048

P5

Number of TCAP component buffers

2048

P6

MAP-SSN start DID

P7

MAP-SSN end DID

2000

P8

CAP-SSN start DID

P9

CAP-SSN end DID

2000

P10

HLR dialog ID start

P11

HLR dialog ID stop

P12

VLR dialog ID start

P13

VLR dialog ID stop

P14

MSC dialog ID start

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Parameter ID

Chapter 2 Public Parameters

Parameter name

Default value

P15

MSC dialog ID stop

P16

Number of BCSM state machines

1000

P17

Number of INSM state machines

1000

P18

Number of activation service filtration

200

P19

Number of call gap

32

P20

Number of SRM state machines

200

P21

Minimum DID of INAP

P22

Maximum DID of INAP

2000

P23

Maximum SCTP ASSOC

128

P24

Maximum SCTP stream

33

P25

Maximum SCTP TWND

72

P26

Maximum SCTP RWND

18

P27

Maximum SCTP connected segment

4000

number
P28

MAP CB TTL

P29

MAP 4k num

800

P30

MAP 4k TTL

P31

MAP 1k num

800

P32

MAP 1k TTL

P33

MAP 256b num

800

P34

MAP 256b TTL

P35

MAP 64b num

800

P36

MAP 64b TTL

P37

MAX CSP state machine

1000

P38

Maximum H323 call CCB

2000

P39

Maximum H323 RAS CCB

10000

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Parameter ID

Chapter 2 Public Parameters

Parameter name

Default value

P40

Maximum H323 original call CCB

20

P41

Maximum H323 spec code CCB

200

P42

Maximum SIPSL trunk

3500

P43

Maximum HSL trunk

3500

P44

Maximum V5ST

1000

P45

Method to create GKID

P46

Console message resend times

P47

Console message resend interval

1000

2.1.3 Modifying Public Parameters


I. Related MML Commands
Command

Function

MOD PUBPRM

Modifying public parameters

LST PUBPRM

Querying configuration information of public parameters

II. Description of Main Parameters


[Parameter]
[Value]

2.2 Parameter Description


2.2.1 P0Maximum Number of Modules
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

2.2.2 P1Number of FSPC CCBs


I. Purpose of Parameter
It indicates the number of CCB on FSPC board supported by the system.

II. Principle of Parameter Modification


The value of this parameter is the maximum number of subscribers divided by four.
The default value is 10000.

2.2.3 P2Number of MSPC CCBs


I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.4 P3Average TCAP Component of Each Dialog


I. Purpose of Parameter
It indicates the average number of TCAP component state machine for each dialog.

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 2. When one of the
following situations arises, the subscriber needs to modify this parameter.
There are not enough component buffersinvocation originated by TCAP
subscribers is rejected because the number of component state machines needs to
be increased when resources are limited.

2.2.5 P4Number of TCAP State Machines


I. Purpose of Parameter
It indicates the maximum number of TCAP dialog state machines.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 2048. When one
of the following situations arises, the subscriber needs to modify this parameter.
There are not enough TCAP dialog state machinesdialogs originated from the
local end are terminated by TCAP because the number of state machines needs to be
increased when resources are limited.

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

2.2.6 P5TCAP Number of TCAP Component Buffers


I. Purpose of Parameter
It indicates the maximum number of TCAP component buffers.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 2048. When one
of the following situations arises, the subscriber needs to modify this parameter.
There are not enough component buffersinvocation originated by TCAP
subscribers is rejected because the number of component state machines needs to
be increased when resources are limited.

2.2.7 P6MAP-SSN Start DID


I. Purpose of Parameter
It indicates the start dialog ID of the MAP subsystem.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 0. There is no
need to modify this default value.

2.2.8 P7MAP-SSN End DID


I. Purpose of Parameter
It indicates the end dialog ID of the MAP subsystem, which, together with the start
dialog ID, defines the dialog ID range of the MAP subsystem.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 2000. There is no
need to modify it.

2.2.9 P8CAP-SSN Start DID


I. Purpose of Parameter
It indicates the start dialog ID of the CAP subsystem.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 0. There is no
need to modify it.

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

2.2.10 P9CAP-SSN End DID


I. Purpose of Parameter
It indicates the end dialog ID of the CAP subsystem, which, together with the start
dialog ID, defines the dialog ID range of the CAP subsystem.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 2000. There is no
need to modify it.

2.2.11 P10HLR Dialog ID Start


I. Purpose of Parameter
It indicates the start dialog ID of the HLR subsystem, which is not used for the
present.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 0. There is no
need to modify it.

2.2.12 P11HLR Dialog ID Stop


I. Purpose of Parameter
It indicates the end dialog ID of the HLR subsystem, which is not used for the present.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 0. There is no
need to modify it.

2.2.13 P12VLR Dialog ID Start


I. Purpose of Parameter
It indicates the start dialog ID of the VLR subsystem, which is not used for the
present.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 0. There is no
need to modify it.

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

2.2.14 P13VLR Dialog ID Stop


I. Purpose of Parameter
It indicates the end dialog ID of the VLR subsystem, which is not used for the present.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 0. There is no
need to modify it.

2.2.15 P14MSC Dialog ID Start


I. Purpose of Parameter
It indicates the start dialog ID of the MSC subsystem, which is not used for the
present.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 0. There is no
need to modify it.

2.2.16 P15MSC Dialog ID Stop


I. Purpose of Parameter
It indicates the end dialog ID of the MSC subsystem, which is not used for the
present.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 0. There is no
need to modify it.

2.2.17 P16
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.18 P17
I. Purpose of Parameter

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.19 P18
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.20 P19
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.21 P20
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.22 P21Minimum DID of INAP


I. Purpose of Parameter
It indicates the start dialog ID of the INAP subsystem.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 0. There is no
need to modify it.

2.2.23 P22Maximum DID of INAP


I. Purpose of Parameter
It indicates the end dialog ID of the INAP subsystem, which, together with the start
dialog ID, defines the dialog ID range of the INAP subsystem.

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 2000. When one
of the following situations arises, the subscriber needs to modify this parameter.
1)

When a customer wants a board to support conversation by more than 2,000


intelligent network (IN) subscribers at the same time, the dialog ID range needs
to be expanded.

2.2.24 P23Maximum SCTP ASSOC


I. Purpose of Parameter
It indicates the maximum number of SCTP connections supported by the BSG board.
This parameter is used to apply for an SCTP memory at the time of initialization.

II. Principle of Parameter Modification


The value range of this parameter is 1255. The default value is 128. When one of
the following situations arises, the subscriber needs to modify this parameter.
1)

If SCTP connection resources are insufficient, application modules (such as


M2UA, M3UA, IUA and V5UA) report the connection fails and the failure cause
value is insufficient connection resources. Please note that, since the SoftX3000
as ASP side can access multiple types of terminals, it is best for the SoftX3000
to use SCTP connections as a client. If it must act as a server, it is best for each
application to provide no more than one server port ID to the exterior. The server
also occupies connection resources. If connection resources are insufficient in
this case, you need to expand this parameter.

2.2.25 P24Maximum SCTP Stream


I. Purpose of Parameter
It is used to specify the default number of input/output streams of SCTP connection.

II. Principle of Parameter Modification


The value range of this parameter is 564. The default value is 255. When one of the
following situations arises, the subscriber needs to modify this parameter.
Since the impact is minor even if the number of streams is small, we recommend
subscribers not modify this parameter.

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

2.2.26 P25Maximum SCTP TWND


I. Purpose of Parameter
It is used to specify the size of the memory of the transmission window applied for by
each SCTP. The unit is KB.

II. Principle of Parameter Modification


The value range of this parameter is 10255. The default value is 72. When one of
the following situations arises, the subscriber needs to modify this parameter.
When applications using SCTP connections often report link congestion, the
parameter needs to be expanded. However, the modification should be modest;
otherwise, too much memory will be occupied, and the board will not be able to run
normally.

2.2.27 P26Maximum SCTP RWND


I. Purpose of Parameter
It is used to specify the size of the memory of the receiving window applied for by
each SCTP. The unit is KB.

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 18. When one of the
following situations arises, the subscriber needs to modify this parameter.
Generally, when the size of the memory of the transmission window is increased, that
of the receiving window should also be expanded approximately by one-fourth of the
increase for the transmission window. If the increase for the transmission window is
small, the size of the memory of the receiving window can remain unchanged.

2.2.28 P27Maximum SCTP Connected Segment Number


I. Purpose of Parameter
It indicates the maximum number of SCTP connected segments. This is not used in
the fixed network version.

II. Principle of Parameter Modification


The value range of this parameter is 065535. The default value is 4000. There is no
need to modify it.

10

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

2.2.29 P28
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.30 P29
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.31 P30
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.32 P31
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.33 P32
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

11

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

2.2.34 P33
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.35 P34
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.36 P35
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.37 P36
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

2.2.38 P37
I. Purpose of Parameter

II. Principle of Parameter Modification


The value range of this parameter is 0255. The default value is 255.

12

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

2.2.39 P38Maximum H323 Call CCB


I. Purpose of Parameter
It indicates the maximum number of H.323 call CCBs supported by the system.

II. Principle of Parameter Modification


The value range of this parameter is 010000. The default value is 2000.

2.2.40 P39Maximum H323 RAS CCB


I. Purpose of Parameter
It indicates the maximum number of H.323 RAS CCBs supported by the system.

II. Principle of Parameter Modification


The value range of this parameter is 050000. The default value is 10000.

2.2.41 P40Maximum H323 Original Call CCB


I. Purpose of Parameter
It indicates the maximum number of H.323 original call CCBs supported by the
system.

II. Principle of Parameter Modification


The value range of this parameter is 040. The default value is 20.

2.2.42 P41Maximum H323 Spec Code CCB


I. Purpose of Parameter
It indicates the maximum number of H.323 special code CCBs supported by the
system.

II. Principle of Parameter Modification


The value range of this parameter is 0400. The default value is 200.

2.2.43 P42Maximum SIPSL Trunk


I. Purpose of Parameter
It indicates the maximum number of SIPSL trunks supported by the system.

II. Principle of Parameter Modification


The value range of this parameter is 05000. The default value is 3500.

13

Technical Manual-System Parameters


U-SYS SoftX3000 SoftSwitch System

Chapter 2 Public Parameters

2.2.44 P43Maximum HSL Trunk


I. Purpose of Parameter
It indicates the maximum number of HSL trunks supported by the system.

II. Principle of Parameter Modification


The value range of this parameter is 05000. The default value is 3500.

2.2.45 P44Maximum V5ST


I. Purpose of Parameter
It indicates the maximum number of V5 subscribers supported by the system.

II. Principle of Parameter Modification


The value range of this parameter is 010000. The default value is 1000.

2.2.46 P45
I. Purpose of Parameter
II. Principle of Parameter Modification
The value range of this parameter is 0255. The default value is 255.

2.2.47 P46Console Message Resend Times


I. Purpose of Parameter
It indicates the times of message resending when the SoftX3000 host communicates
with the console terminal.

II. Principle of Parameter Modification


The value range of this parameter is 250. The default value is 8.

2.2.48 P47Console Message Resend Interval


I. Purpose of Parameter
It indicates the interval between message resendings when the SoftX3000 host
communicates with the console terminal. The unit is millisecond.

II. Principle of Parameter Modification


The value range of this parameter is 100010000. The default value is 1000.

14