You are on page 1of 10

3 Port Solenoid Valve

Direct Operated Poppet Type

Series VK300
Rubber Seal

[Option]

VV061
Universal porting

Specifications

Available for N.C. valve, N.O. valve, divider


valve, selector valve, etc.

C: 0.80 dm3/(sbar)
(Passage 2 3)

Compact: Width 18 x Length 63 (mm)


Low power consumption
4 W DC (Standard type)
2 W DC (Low wattage type)

Suitable for use in vacuum


applications 101.2 kPa
Suitable for use in copper-free
applications
The portions that come in contact with fluids do
not contain copper, thus enabling the standard
product to be used as is.

Direct operated type 2 position single solenoid


Type of actuation
Air
Fluid
5 to 50C (No freezing. Refer to page 5.)
Ambient and fluid temperature
(1)
10 ms or less (Standard), 15 ms or less (Low power consumption type)
Response time (at 0.5 MPa)
Non-locking push type
Manual override
Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
Lubrication
Unrestricted
Mounting orientation
300/50 m/s2
Impact/Vibration resistance (2)
Dustproof
Enclosure
Note1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20C, at rated voltage,
without surge suppressor)
Note2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and
de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)

Electrical entry

Grommet (G), DIN terminal (D)


100, 110, 200, 220, 240
AC
Rated voltage (V)
12, 24
DC
10% of rated voltage
Allowable voltage fluctuation
9.5 VA/50 Hz, 8 VA/60 Hz
Inrush
Standard
type
7 VA/50 Hz, 5 VA/60 Hz
Holding
Apparent power (AC)
3.5 VA/50 Hz, 3.3 VA/60 Hz
Inrush
Continuous
duty type
3 VA/50 Hz, 2.8 VA/60 Hz
Holding
W/o indicator light 4 W (Standard), 2 W (Low power consumption type)
Power consumption (DC)
W/ indicator light 4.3 W (Standard), 2.3 W (Low power consumption type)
Varistor
AC
Surge voltage suppressor
Diode (Varistor for 12 VDC or less)
DC
Neon bulb
AC
Indicator light
LED
DC

Base mounted
Symbol
Body ported
(A)2

At the rated voltage

Base mounted
(A)2

(R)3 1(P)

(P)1 3(R)

Flow Characteristics/Weight

Base mounted Body ported


(With sub-plate)

Valve model

Operating
pressure
range
(MPa)

VK332
VK332Y (For low wattage, 2 W DC) 0 to 0.7
VK332E (Continuous duty type)
VK332V (For vacuum)
101.2 kPa
to 0.1
VK332W (Low wattage, vacuum)
VK334
VK334Y (For low wattage, 2 W DC) 0 to 0.7
VK334E (Continuous duty type)
101.2 kPa
VK334V (For vacuum)
to 0.1
VK334W (Low wattage, vacuum)

Port
size

M5 x 0.8

18

1 2 (P A)
C
[dm3/
(sbar)]

0.47
0.41
0.41
0.47
0.41
0.85
0.65
0.65
0.85
0.65

0.44
0.27
0.27
0.44
0.27
0.26
0.24
0.24
0.26
0.24

Flow characteristics
2 3 (A R)
3 2 (R A)

Cv

C
[dm3/
(sbar)]

0.13
0.10
0.10
0.13
0.10
0.19
0.15
0.15
0.19
0.15

0.47
0.39
0.39
0.47
0.39
0.80
0.55
0.55
0.80
0.55

0.40
0.35
0.35
0.40
0.35
0.27
0.32
0.32
0.27
0.32

V100
S070
VQD
VQD-V
VKF
VK
VT
VS4

Solenoid Specifications

Body ported

VV100

Cv

C
[dm3/
(sbar)]

0.13
0.10
0.10
0.13
0.10
0.19
0.14
0.14
0.19
0.14

0.48
0.41
0.41
0.48
0.41
0.83
0.65
0.65
0.83
0.65

0.47
0.38
0.38
0.47
0.38
0.26
0.15
0.15
0.26
0.15

2 1 (A P)

Cv

C
[dm3/
(sbar)]

Cv

0.14
0.11
0.11
0.14
0.11
0.20
0.14
0.14
0.20
0.14

0.47
0.38
0.38
0.47
0.38
0.76
0.41
0.41
0.76
0.41

0.44
0.40
0.40
0.44
0.40
0.41
0.63
0.63
0.41
0.63

0.13
0.10
0.10
0.13
0.10
0.20
0.14
0.14
0.20
0.14

Weight (g)
Grommet

80

120

Mounting with VK300


Series VK300 can be mounted on the manifold base
VV5K3 of VK 3000 series. Refer to page 1992 for details.

1979

VS3

Series

VK300
How to Order

Note) CE-compliant:
For DIN terminal only

[Option]

Electrical entry
G: Grommet
(Lead wire length:
300 mm)

CE-compliant

Rated voltage
1
2
3
4
5
6
7

100 VAC, 50/60 Hz


200 VAC, 50/60 Hz
110 VAC, 50/60 Hz
220 VAC, 50/60 Hz
24 VDC
12 VDC
240 VAC, 50/60 Hz
Note1) Applicable only for DIN
terminal type
Note2) For other rated voltages,
please consult with SMC.

H: Grommet
(Lead wire length:
600 mm)

For the connector part number, refer to page 1988.

Port size (A port)


M5
01

DO : DIN terminal
(Without connector)

D: DIN
terminal

Option

M5 x 0.8
Rc 1 8

Nil

P, R port: M5

Thread
type
Nil

F
N
T

Rc
G
NPT
NPTF

None
With bracket
(Not assembled)

Option Part No.


Description
Bracket

Body ported

VK332

1 G

M5

Base mounted

VK334

1 G

01

Part no.
VK300-43-2A

Note
With screw

CE-compliant

Nil
Q
CE-compliant
Note) Applicable only for DIN
terminal type

Port size
Without sub-plate
Rc 1 8 (With sub-plate)

Nil
01

Valve option
Nil
V
Y
W
E

Standard type
For vacuum
For low wattage
For vacuum/low wattage
Continuous duty type

For the applicable voltage,


please contact SMC.

Light/Surge voltage suppressor CE-compliant


Nil
S

None
With surge voltage suppressor

With light/surge voltage


suppressor (Type D only)

Since the indicator light is bulit in connector, thus,


DOZ is not available.

Construction
Symbol
(A)2

(R)3 1(P)

Component Parts
No.
1
2
3
4
5
6

1980

Material
Description
Aluminum die-casted
Body
Resin
Cover
Resin
End cover
Spool valve assembly
Aluminum, NBR
Return spring
Stainless steel
Molded coil
Resin

Note
Platinum silver
Black
Black

Black

Series VK300

Manifold Specifications
Specifications
Valve stations

1 to 20
Body ported, Base mounted
Body ported

Common SUP, Common EXH


Common SUP, Individual EXH

Piping method

VV061
VV3K3-S42-05-01

Note) CE-compliant:
For DIN terminal only

VV3K3-20-04

Common SUP/Common EXH


How to Order
Type 20: Body ported
A port:
Rc 1/8, M5 x 0.8

Valve stations

Option

1 station

01

Applicable solenoid valve


VK332--M5(-Q)
VK332--01(-Q)

05

VV3K3 20

(A port top ported)

Nil

20

20 stations

Nil
00F
00N
00T

05

VV3K3 40
P port: Rc 1/8

Bracket

Rc
G
NPT
NPTF

Type 42: Base mounted

1 station

A port: Rc 1/8

01
20

20 stations

Port size
Rc 1 8

01

How to Order

VV3K3

(A port side ported)

Nil
F
N
T

42

05

Solenoid direction
Nil
P port: Rc 1/8
R port: Rc 1/8

01
C4
C6

Same side
of A port

01

20 stations

VK

Applicable blanking plate


assembly

VS4

Option

VK300-42-1A

Nil

None

Bracket

VS3

With bracket
(Not mounted)

VK300-43-1A
CE-compliant

Rc
G
NPT
NPTF

Nil
Q

CE-compliant

Note) Applicable only for


DIN terminal type

Applicable solenoid valve


VK334-(-Q)

01

Applicable blanking plate


assembly

Thread
type

Rc 1 8
4 cassette
6 cassette

Nil
F
N
T

VK300-42-1A

Rc
G
NPT
NPTF

CE-compliant
Nil

Q
CE-compliant
Note) Applicable only for
DIN terminal type

P port: Rc 1/8
R port: Rc 1/8

Common SUP/Individual EXH


How to Order

Type 21: Body ported

VV3K3 21

(A port top ported)


A port:
Rc 1/8, M5 x 0.8

01

P port: Rc 1/8

1 station

R port: Rc 1/8

Applicable solenoid valve


VK332--M5(-Q)
VK332--01(-Q)

05

Valve stations

20

20 stations

VQD
VKF

Nil

Q
CE-compliant
Note) Applicable only for
DIN terminal type

1 station

20

S070

VT

Valve stations

Type S42
(Solenoids on the same side of A port)

V100

Applicable solenoid valve


VK334-(-Q)

Port size

Opposite side
of A port

VV100

VQD-V

VK300-43-1A
CE-compliant

01
Thread
type

Valve stations

R port: Rc 1/8

A port: Rc 1/8

VK300-42-1A

How to Order

(A port bottom ported)

A port: Rc 1/8

Applicable blanking plate


assembly

P, R port
thread type

None
With bracket
(Not mounted)

P port: Rc 1/8
R port: Rc 1/8

Type 40: Base mounted

[Option]

P, R port
thread type
Nil
00F
00N
00T

Rc
G
NPT
NPTF

Applicable blanking plate


assembly

VK300-42-1A
CE-compliant

Nil

Q
CE-compliant
Note) Applicable only for
DIN terminal type

1981

Series

VK300

Combinations of Solenoid Valve, Manifold Gasket and Manifold Base


3 port body ported: VK332

3 port base mounted: VK334


M3 x 26
Round head
combination screw

M3 x 26
Round head
combination screw

Manifold gasket
Manifold gasket

Applicable base

Applicable base
VV3K3-20 (-Q)
21 (-Q)
VV5K3-20 (-Q)
21 (-Q)

Manifold gasket and screw assembly

VK300-45-1 Sub-plate
VV3K3-40 (-Q)
(S) 42 (-Q)
VV5K3-40 (-Q) Manifold base
(S) 41 (-Q)
(S) 42 (-Q)

Manifold base

Body ported
VK300-41-1A

Base mounted
VK300-41-2A

Note1) Mounting direction is fixed, do not mount on opposite side.


Note2) Series VK300 can be mounted on the manifold base VV5K3 of VK 3000 series. Refer to page 1992 for details.

Combinations of Blanking Plate Assembly and Manifold Base


Blanking plate assembly: VK300-42-1A
M3 x 8
Round head
combination screw

Blanking plate

Manifold gasket for


blanking plate

Caution
Mounting Screw
Tightening Torques

Applicable base: In common for all types of VV3K3 models

1982

M3: 0.6 Nm

Caution

Mounting Screw
Tightening Torques

M3: 0.6 Nm

3 Port Solenoid Valve


Direct Operated Poppet Type

VK300

Series

Dimensions: Body Ported


Grommet: VK332-G-M5

DIN terminal: VK332-D-M5


68.8

(Bracket)

Max.10

9 14

VV061

(Mounting screw)

300

2 x M2.5 x 0.45
(Mounting screw)

Manual override
(Non-locking)

(Lead wire length)

2 x 3.2
(Mounting hole for manifold)

13

VV100
A
2 x 3.2
(Mounting hole for manifold)

16

VQD-V
VKF

4
50.4

24

21

(Bleed hole)

57.9
63.4

(Mounting hole)
2 x 3.5
(Mounting hole)

VT
VS3

3 x M5 x 0.8
(P, A, R port)

Refer to grommet type for other dimensions.

Dimensions: Base Mounted


DIN terminal: VK334-D-01
2 x 4.3
(Mounting hole)

26

25

22

A
Max.10
2 x 4.3
(Mounting
hole)

68.8

Applicable cable O.D: 3.5 to 7


Pg7

300

3 x Rc 1/8
(Piping port)

20

R
7.5

44.5

4.5

78.4

70.9

(Lead wire length)

3 x Rc 1/8
(Piping port)

VK
VS4

62.8

2.3

Manual override
(Non-locking)

S070
VQD

Applicable cable O.D: 3.5 to 7


Pg7

Grommet: VK334-G-01

V100

13.5 13
34

Refer to grommet type for other dimensions.

1983

Series

VK300

Type 20 Manifold/Body Ported (Top ported)


VV3K3-20- Stations

n1 = Number of VK300

Grommet: G

DIN terminal: D

2 x 4.5
(Mounting hole)

Manual override
(Non-locking)
n1 x Rc 1/8
(A port)

Max.10

Applicable cable O.D: 3.5 to 7

300
(Lead wire length)

78.4
70.9
Pg7

4 x Rc 1/8
(P, R port)

2 x 4.5
(Mounting
hole)

4 x Rc1/8
(P, R port)

(Pitch)

7
44.5

2.3

7 20
34

68.8

4 x M3 x 0.5 depth 6
(Bracket mounting screw)

L Dimension
n

L1
L2
L3

1984

1
35
27
13

2
54
46
32

3
73
65
51

4
92
84
70

5
111
103
89

6
130
122
108

7
149
141
127

8
168
160
146

9
187
179
165

10
206
198
184

11
225
217
203

12
244
236
222

13
263
255
241

14
282
274
260

15
301
293
279

16
320
312
298

17
339
331
317

18
358
350
336

n: Stations
19
20
377 396
369 388
355 374

3 Port Solenoid Valve


Direct Operated Poppet Type

VK300

Series

Type 21 Manifold/Body Ported (Top ported)


VV3K3-21- Stations

n1 = Number of VK300

Grommet: G

DIN terminal: D

VV061
Manual override
(Non-locking)
Max.10

V100

70.9
Pg7

S070

2 x Rc 1/8
(P port)

2 x Rc 1/8
(P port)

19

(Pitch)

VQD
VQD-V

35

300
(Lead wire length)

78.4

68.8

n1 x Rc 1/8
(A port)
2 x 4.5
(Mounting hole)

VV100

Applicable cable O.D: 3.5 to 7

VKF

11
44.5

VK
VT
VS4
VS3
n x Rc 1/8
(R port)

(Pitch)

L Dimension
L

L1
L2

1
38
27

2
57
46

3
76
65

4
95
84

5
114
103

6
133
122

7
152
141

8
171
160

9
190
179

10
209
198

11
228
217

12
247
236

13
266
255

14
285
274

15
304
293

16
323
312

17
342
331

18
361
350

n: Stations
19
20
380 399
369 388

1985

Series

VK300

Type 40 Manifold/Base Mounted (Bottom ported)


VV3K3-40- Stations -01
DIN terminal: D
Max.10

Grommet: G
2 x 4.5
(Mounting hole)

Manual override
(Non-locking)

300
(Lead wire length)

Applicable cable O.D: 3.5 to 7


83.4
75.9
Pg7

4 x Rc 1/8
(P, R port)

4 x Rc 1/8
(P, R port)
8 23
39

69.8

2 x 4.5
(Mounting hole)

(Pitch)

1.5
10.5
49.5

4 x M3 x 0.5 depth 6
(Bracket mounting screw)

(Pitch)
n x Rc 1/8
(A port)

L Dimension
n

L1
L2
L3

1986

1
37
27
13

2
56
46
32

3
75
65
51

4
94
84
70

5
113
103
89

6
132
122
108

7
151
141
127

8
170
160
146

9
189
179
165

10
208
198
184

11
227
217
203

12
246
236
222

13
265
255
241

14
284
274
260

15
303
293
279

16
322
312
298

17
341
331
317

18
360
350
336

n: Stations
19
20
379 398
369 388
355 374

3 Port Solenoid Valve


Direct Operated Poppet Type

Series

VK300

Type 42 Manifold/Base Mounted (Side ported)


VV3K3-42- Stations -01
Grommet: G

DIN terminal: D

VV061

Max.10

Applicable cable O.D: 3.5 to 7


Manual override
(Non-locking)

83.4
75.9
Pg7

300
(Lead wire length)

VV100
11.5

18

VQD
VQD-V

11.5

8.5

S070

37

70.8
(Pitch)

2 x 4.5
(Mounting hole)

V100

4 x Rc 1/8
(P, R port)

4 x Rc 1/8
(P, R port)

VKF
VK
VT
VS4

(Pitch)

VS3

n x Rc 1/8
(A port)

Solenoid at A port side:


VV3K3-S42- Stations -

Built-in One-touch fitting: VV3K3-42- Stations -C4, C6

(Pitch)
2 x 4.5
(Mounting hole)

Manual override
(Non-locking)

300
(Lead wire length)

L1
L2

1
38
28

2
57
47

3
76
66

300
(Lead wire length)

(Pitch)

4
95
85

5
114
104

Manual override
(Non-locking)

n x Rc 1/8
(A port)

(Pitch)

n x One-touch fitting
C4: Applicable tubing T0425
C6: Applicable tubing T0604
(A port)

Max.5.5

2 x 4.5
(Mounting hole)

4 x Rc 1/8
(P, R port)

(Pitch)

Refer to the above drawing for DIN terminal dimensions.

Refer to the above drawing for other


dimensions.

6
133
123

14
285
275

7
152
142

8
171
161

9
190
180

10
209
199

11
228
218

12
247
237

13
266
256

15
304
294

16
323
313

17
342
332

18
361
351

19
380
370

20
399
389

1987

Series VK300

Specific Product Precautions


Be sure to read before handling. Refer to front matter 53 for Safety Instructions
and pages 3 to 8 for 3/4/5 Port Solenoid Valve Precautions.

Caution

Caution
How to Wire DIN Terminal

Ground nut
Tightening torque
1.65 to 2.5 Nm

Holding screw
Tightening torque
0.3 to 0.4 Nm

Washer
Grommet
(Rubber)
(Voltage symbol)
Refer to the
table below.
Terminal screw (3 positions)
Tightening torque
0.2 to 0.25 Nm

Housing
(Position for
light mounting)
Terminal block
Slot area

Connector part no.: VK300-82-1


Part no. of connector with indicator light

Rated voltage Voltage symbol


100 VAC
100V
110 VAC
110V
200 VAC
200V
220 VAC
220V
240 VAC
240V
6 VDC
6V
12 VDC
12V
24 VDC
24VD
48 VDC
48VD

Circuit with indicator light


AC circuit
diagram

12 VDC or less
circuit diagram
LED

NL

NL: Neon bulb


R: Resister

Part no.
VK300-82-2-01
VK300-82-2-03
VK300-82-2-02
VK300-82-2-04
VK300-82-2-07
VK300-82-4-51
VK300-82-4-06
VK300-82-3-05
VK300-82-3-53

1988

LED: Light emitting


D: Protective
diode
diode
R: Resister
LED: Light emitting
diode
R: Resister

Part no.
symbol

Coil
Coil

Coil

Diode

Coil

Diode

Coil

Coil

Varistor
Varistor

No.2

Coil

Diode

No.1(+)

LED

Coil

No.1(+)

None

1. Since this valve has slight air leakage,


it can not be used for holding vacuum
(including positive pressure holding) in
the pressure container.

Recommended for continuous duty with


long time loading.

No.2()

Continuous Duty Type: VK33E

No.1

No.2

Caution

No.1

None
No.2

Precautions on connection of 24 V or more DC


Grommet type should be connected as following;
Red lead wire for (+) side, Black lead wire for ()
side respectively.
With the DIN terminal, connect the positive (+) side
to the connectors no. 1 terminal, and the negative
() side to the no. 2 terminal. [Refer to the marks
on the terminal board.]
For 12 VDC or below, there is no positive (+) or
negative () directionality.

Grommet type

Red (+)
Black ()
Surge voltage
suppressor

Vacuum Spec. Type: VK33V (VK33W)


In contrast to the standard product, this
vacuum specification valve has less air
leakage at low pressures, a feature that
should be taken into consideration when
using this valve for vacuum applications.

Caution

No.2()

Black ()

DIN terminal type


Marking

24 VDC or more
circuit diagram

Diode

Red (+)

No.1
Neon
bulb

No.2

Indicator light
(Built-in connector)

Surge voltage
suppressor

D LED R
1

Neon
bulb

When mounting a valve on the manifold


base or sub-plate, etc., the mounting
orientation is already decided. If mounted
in a wrong direction, the equipment to be
connected may result in malfunction.
Refer to pages 1983 to 1987 for external
dimensions in mounting.

Coil

DC
6V
12V

No.1

None

No.2

Valve Mounting Direction

Coil

No.2

Diode

No.1

Varistor

DC
24V
48V

No.1

Coil

Use caution in wiring because it will not meet


the IP65 (enclosure) standard if you use the
other cable than prescribed heavy-duty cable of
size (3.5 to 7).
Tighten the ground nut and set screw within the
specified range of torque.
Change of electrical entry (Orientation)
After separating terminal block and housing,
the cable entry direction can be changed by
attaching the housing in the desired direction
(4 directions in 90 increments).
In the case of w/ indicator light, avoid
damaging the light with lead wire.
Precautions
Plug a connector in or out vertically, never at
an angle.
Applicable cable
O.D.: 3.5 to 7
(Reference)
0.5 mm2 2 core and 3 core wires equivalent
to JIS C 3306

DIN terminal (D)

Standard: Continuous
Y, V, W
duty type (E)

Coil

Caution

Continuous
duty type (E)

Diode

AC

Grommet (G)
Standard:
Y, V, W

Varistor

Rated
voltage

Varistor

Connection
1. Loosen the set screw and pull out the
connector from the terminal block of the
solenoid.
2. Remove screw and insert screwdriver into
the slit area near the bottom of terminal
block to separate block and housing.
3. Loosen the terminal screws (slotted
screws) on the terminal block, insert the
core of the lead wire into the terminal,
and attach securely with the terminal
screws.
4. Tighten the ground nut to secure the cable.

With indicator light W/o indicator light With indicator light W/o indicator light With indicator light W/o indicator light

Warning

Light/Surge Voltage Suppressor

(Built-in terminal)

Marking
AC, 12 VDC or
less for DC

For 24 V or more

1. This model is for continuous duty, not


for high cycle rates. But even in low
cycle rates, if energizing the valve more
than once a day, please consult with
SMC.
2. Energizing solenoid should be done at
least once in 30 days.

How to Calculate the Flow Rate


For obtaining the flow rate, refer to front
matters 42 to 45.

You might also like