You are on page 1of 32

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

HSVF SERIES
TROUBLESHOOTING MANUAL

This manual is the property of Hyundai Elevator Co., Ltd


and is loaned subject to return upon demand.
Contents of this publication shall not be reproduced in any
form without written permission of Hyundai Elevator Co., Ltd.

HYUNDAI ELEVATOR CO., LTD.

Rev. Commemts :

HELCO-C5-003-01

- 1 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

TABLE OF CONTENTS
1. INTRODUCTION 3
1-1. Main feature 3
2. INSTALLATION 3
2-1. Safety 3
3. BOARDS ADJUSTMENT 5
3-1. MCU Board & PIO Board Adjustment 5
3-2. GIO Board Adjustment 6
3-3. TNP Board Adjustment 8
3-4. CCB-7 Board Adjustment 10
3-5. OPB-340 Board Adjustment 11
3-6. HPI/HIP CAN Board Adjustment 12
3-7. Voice Synthesizer 15
3-8. CPI-CAN Board Adjustment 16
3-9. LS Board Adjustment 17
4. INSPECTION OPERATION 18
4-1. Brake line connection 18
4-2. Power line connection 18
4-3. Motor line connection 18
4-4. Check points after turning on the power 18
4-5. Operate Inspection 19
5. INITIALIZING OPERATION 20
5-1. Purpose 20
5-2. Check subjects 20
5-3. Operating Procedure 21
5-4. Cautious Subjects 21
5-5. Initialization Flow Chart 22
6. LOAD COMPENSATING DEVICE SETUP 23
6-1. Purpose 23
6-2. Procedure 23
Rev. Commemts :

HELCO-C5-003-01

- 2 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

1. INTRODUCTION
* The manual describes the troubleshooting method of Hyundai "HSVF" elevator system.
* In this manual, elevator troubles are explained in two cases i.e.
* "Condition of operation impossible" means the impossible state of starting and running of
elevator by certain causes of troubles.
* "Condition of operation possible" means the possible state of running, but normal service for
passenger's is not made by several causes of troubles.
* As troubles are describes by trouble modes and causes of troubles and troubleshooting
methods are explained.
* This manual shall be helpful for prompt and accurate troubleshooting of the troubles that
could happen at jobsite.
* System power and Boards are explained in "HSVF INSTALLATION MANUAL AND ADJUSTMENT
MANUAL"
* HHT use methods are explained in "HSVF HHT MANUAL".

Rev. Commemts :

HELCO-C5-003-01

- 3 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

2. TROUBLESHOOING METHOD WITH HHT


2-1. Connection and initialization of HHT
1) Connect HHT to MCU "H8" connector at elevator stopped.
2) Push "ESC" and "ENTER" key for 1 seconds simultaneously.
3) Then, HHT initial menu is displayed normally.
4) Please refer to "STVF7 HHT MANUAL".
ID
0.

HHT Main Menu


EL.STATUS

Remark
Total Information Mode

1.

IN/OUT

2.

ERROR

3.

SETUP

4.

MANAGEMENT

Field test, Factory test, Count E/L running times

5.

INFO

Version information

PIO I/O, Car I/O, Call I/O, INVERTER I/O, RMS I/O,
Group I/O, CAN STATUS, EXT I/O
Error, Error records, Erasing records, Hall Error
Spec. change, Device set up, Time set up,
Initialization, Load set up

[Table 1. HHT Main Menu]

Rev. Commemts :

HELCO-C5-003-01

- 4 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

HSVF Trouble manual

HSVF SERIES
TROUBLESHOOTING MANUAL

2011.12.23

Document Number :

2-2. Total Information Mode


C 1

5 6 7 8

11

15 16

Position

1verse
1,2 column

1verse
3,4 column
1v
1v
1v
1v
1v
1v
2v
2v

5c
6c
7c
8,9c
11~12c
15,16c
1,2,3c
11~15c

A u C D

F 6 8

Commit

( B 1

/ 3 3

[ 0 9

2 5 ]

Display
no mode
F1 1st fireman op.
auto
F2 2nd fireman op.
In-Car inspection
Mv independent op.
On-Car inspection Ep Emergency op.
Machine room
Emergency
Mc
El
inspection
Landing op.
Fi
Initialization
Eq Earthquake op.
Pk Parking op.
Rp Sub brake in
Fr
Fireman Return
Ar Arrange op.
OG Openning
RG Rear Door Openning
OP Open
RO Rear Door Open
CG Closing
RC Raer Door Close
CD Close
: Up, : Stop, : Down
ULA, DZ, DLA
(Space) : Service Floor, * : non-Service Floor
No
Au
In
On

Elevator Status

Door Status
Direction
Door zone sensor
Non-Stop Floor
Absolute Floor
Floor display
Total Floor
Error display
Current time

Floor display on Indicator


---:
--- No error, Fxx:
Fxx error code
Hour : Minute

[Table 2. Total Information Mode]

Rev. Commemts :

HELCO-C5-003-01

- 5 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

HSVF Trouble manual

HSVF SERIES
TROUBLESHOOTING MANUAL

2011.12.23

Document Number :

2-3. IN/OUT MODE


(1) Method of checking IN/OUT status
ex) : 1.1 PIO input status
P

N P U T
(
0
0 X 0 0 C 2 0 0 1

)
7

PIO Input (0) mode


DATA : 32bit hex value

(a) (b) (a) (b) (a) (b) (a) (b)

-(b)
-(a)
-(b)
-(a)

:
:
:
:

7
1
2
C

=>
=>
=>
=>

29,41,40 : ON
AUTO : ON
FMR : ON
MCI,MC2I : ON

* It is same as the other in/out mode.


(2) PIO Input (1. IN/OUT >> 1-1. PIO Input)
SIGNAL NAME
(a)

HHT

PIO Input [0]

PIO Input [1]

PIO Input [2]

8
bit8
MDN
DLS
MC2I
BKB
PDN

4
bit7
MUP
PLDL
MCI
FMR2
PUP

30B

BKS

(b)
2
1
8
bit5
bit4
bit6
AUTO BKOP
MCS
PLDH PLDM PLUM
ELDI
EQP
EQS
RDZ
FDZ
EMPO
PHAND PAUTO RNBL

ZSP

RUN

DLD

4
bit3
40
PLUH
PARK
HOME
WLS

2
bit2
41
PLUL
FMR
ATS
PDLS

1
bit1
29
ULS
RBKI
MT
CTOL

DLA

DZ

ULA

[Table 3. PIO Input]


a. If elevator is in machine room inspection, check that "PIO Input[0]" is
whether

- - - - - - 2 7 or not. (MCS, 40, 41, 29)

b. If limit switches are in good condition, check that "PIO Input[0]" is


whether

- - - - E 7 - -

or not. (DLS, PLDL, PLDH, PLUH, PLUL, ULS)

c. If door zone sensors are in good condition, check that "PIO Input[2]" is
whether

- - - - - - - 7

or not. (DLA, DZ, ULA)

d. If inverter is in good condition at stopped, check that "PIO Input[2]" is


whether

- - - - - - A -

or not. (30B, ZSP)

Rev. Commemts :

HELCO-C5-003-01

- 6 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

HSVF Trouble manual

HSVF SERIES
TROUBLESHOOTING MANUAL

2011.12.23

Document Number :

(3) PIO Output (1. IN/OUT >> 1-2. PIO Output)


HHT
XRLY

PIO Output [0]

MFAN

SIGNAL NAME
REV
FWD
MC2
SPO2 SPO1 ELDO

MC1
BRKC

RBK
BRKB
RST

BRKA
ALARM
INIT

[Table 4. PIO Output]


a. If elevator is stopped, check that "PIO Output[0]" is
whether

- - - - - - - 6

* SSVF7 :

or not. (MC1, RBK)

- - - - - - - E

(MC2, MC1, RBK)

b. If elevator is moving upward, check that "PIO Output[0]" is


whether

- - - - - - 1 7

* SSVF7 :

or not. (FWD, MC1, RBK, BRKA)

- - - - - - 1 F

(FWD, MC2, MC1, RBK, BRKA)

(4) Car Input (1. IN/OUT >> 1-3. Car Input)


HHT
FC5
OL
DCS

CarSigIn [0]

NDZ
FULL
ODD

FC3
L70
DCB
EVEN

Signal Name
FR2
FR1 ONDN ONUP ONS
L30
EE
SE
DCL
DOL
DOB
INS
AUTO
EACH MOVE PASS
ATT
PWR

CarSigIn [1]

REE

CarSigIn [2]

RDCS

RSE

RDCL

RDOL

RDCB RDOB

CarSigIn [3]

[Table 5. Car Input]


a. If inspection switch on the cage is on, check that "Car Input[0]"
is whether

- - - - - - - 1

or not. (ONS)

b. If door open button is pushed, check that "Car Input[0]" is


whether

- - 1 - - - - -

or not. (DOB)

Rev. Commemts :

HELCO-C5-003-01

- 7 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF Trouble manual

HSVF SERIES
TROUBLESHOOTING MANUAL

Document Number :

(5) Car Output (1. IN/OUT >> 1-4. Car Output)


HHT
CarSigOut [0]

LTR
DST
VEQ

CarSigOut [1]

UDST
DUP

Signal Name
FST
FDR
VOL
LED3

DLOCK VWEL

VFR
DDN

BN2

VCL

VOP

FR2R
LED2

CLR
LED1

OPR
OLBZ

VFD

VIP

NUDGR

LED4 RNUGR RCLR

ROPR

REAR

VCNCL RDOOR FDOOR


CarSigOut [2]

CarSigOut [3]

[Table 6. Car output]


(6) CAN Status (1. IN/OUT >> 1-D. CAN Status)
HHT
CAN.Car Status

Commit
Car part CAN status register value :
* normal : 0x0000000C
* abnormal : 0x80000044
Hall part CAN status register value :

CAN.Hall Status

* normal : 0x0000000C
* abnormal : 0x80000044
Normal/Front Hall detected ID 1~32 floor

HallScan1 1-32

HallScan1 33-64
HallScan2 1-32
HallScan2 33-64

(Detected Hall ID bit is displayed "1")


* example 8 floor = 0x000000FF
* example 15 floor = 0x00007FFF
Normal/Front Hall detected ID 33~64 floor
Handicap/Rear Hall detected ID 1~32 floor
Handicap/Rear Hall detected ID 33~64 floor
Detected ID of OPB board :
*0xHGFEDCBA

Car Scan

--

ExIO2

ExIO1

LS

OPB4

OPB3

OPB2

OPB1

[Table 7. CAN Status]


Rev. Commemts :

HELCO-C5-003-01

- 8 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

2-4. ERROR MENU


ID

HHT Display

Commit

2.1

Error List

Error occurrence / cancellation list

2.2
2.3

Clear Error
Hall Error

Clear error occurrence / cancellation list


Hall board error
[Table 8. ERROR MENU]

1) Error List (2.ERROR >> 2.1 Error List)


- Error list is recorded with error code, occurrence time, cancellation time in regular
sequence.
- The total number of recorded lists is 64.
ex 1) 2009. 2. 17 15:55:47.11
0 0 2

F 1 1

F11 occurrence
s e t

0 9 0 2 1 7 - 1 5 5 5 4 7 . 1 1
ex 2) 2009. 2. 17 15:59:58.87
0 0 1

F 1 1

F11 cancellation
c

0 9 0 2 1 7 - 1 5 5 9 5 8 . 8 7

2) Clear Error (2.ERROR >> 2.2 Clear Error)


- Clear the total 64 error records.

ex) Clear Error /Cln Error List? push


select "yes" using
C l n

E r

button

button push
r o r

L i

button

s t ?
Y e s

Rev. Commemts :

HELCO-C5-003-01

- 9 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

HSVF Trouble manual

HSVF SERIES
TROUBLESHOOTING MANUAL

2011.12.23

Document Number :

3) Hall Error (2.ERROR >> 2.3 Hall Error)


- Undetected or dis-order hall board ID bit is displayed "1".
- Check the hall board. Refer to "STVF7 ADJUSTMENT MANUAL".
HHT
HallErr.1 1-32
HallErr.1 33-64
HallErr.2 1-32
HallErr.2 33-64

Commit
Normal/Front Hall error 1~32 floor
Normal/Front Hall error 33~64 floor
Handicap/Rear Hall error 1~32 floor
Handicap/Rear Hall error 33~64 floor

ex) Hall ID error is detected at 1, 2, 6, 8 floor


H a

Hall Err.1 1-32 mode

1 - 3 2

0 X 0 0 0 0 0 0 A

DATA : 32bit hex value

25~3217~24 9~16 1~8


0X000000A3 " ---- 8 7 6 5
DATA "A3 " ---- 1 0 1 0

4 3 2 1 floor
0 0 1 1

* If there is no hall error, DATA is displayed 0x00000000.

Rev. Commemts :

HELCO-C5-003-01

- 10 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

3. ERROR CODES
F11

Safety Line Error


- Safety line error(when elevator is stopped).

State

- Impossible to move in inspection, auto operation and etc.,


- Elec.W.diagram : COL 3A, 3B, 3C, 4A

Reference

- MCU Bd HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "29"
- Check power supply DC110V, DC24V.

Check
Point

- Check X29 relay of TNP board.


- Check switches of safety line.
- Check HHT 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 29
- Check H2,H3 cable between PIO board and TNP board.

F21

Running Time Error


- Available running time error

State

- stop running impossible to move in any operation


- HHT : 3.SETUP>>3.1 basic>>31b Field>>B43 ATStall Time

Reference

- HHT : 3.SETUP>>3.1 basic>>31b Field>>B01 Total FL Num


- Check brake operation.

Check
Point

- Check the signal "FWD/REV" transmission from MCU to inverter.


- Check the signal "BKS, RUN" of inverter.
- Check inverter HHT "MONITOR>>Floor data>>1F ~ top floor.
- Check total floor data between MCU and inverter.

F31
State

DPRAM Error
- DPRAM cable error between MCU and inverter

Reference - Elec.W.diagram : COL 1A, 1B, 1C


Check

- Check the DPRAM cable from MCU H6 to inverter CN7.

Point

- Check the DPRAM cable shield and ground.

Rev. Commemts :

HELCO-C5-003-01

- 11 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F41

HSVF Trouble manual


Document Number :

FWD/REV Error
- (in inspection) MCU commands to stop, but FWD/REV signal output
to inverter.

State

- stop running "MC1" contactor off (turning inverter off)


- Elec.W.diagram : COL 1A, 1B, 1C
Reference - MCU HHT : 1.IN/OUT>>1.2 PIO Output>>PIO Output[0] "FWD","REV"
- MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input[2] "ZSP","RUN"
Check

- Check "FWD","REV" signal of HHT and relay of PIO board.

Point

- Check inverter HHT "MONITOR>>I/O>>Y1,2,3".

F51

"MC1" Contactor Error


- MCU commands "MCX1" on, but "MC1" contactor is not on.

State

- Impossible to move in any operation.


- Elec.W.diagram : COL 4A

Reference - MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input[0] "MCI"


- MCU HHT : 1.IN/OUT>>1.2 PIO Output>>PIO Output[0] "MC1"
Check
Point

- Check "MCX1" relay of TNP board.


- Check PIO board.
- Check "MC1" contactor connection.

F61

"MC2" Contactor Stuck Error


- MCU commands "MCX2" off, but "MC2" contactor is not off.

State

- Impossible to move in any operation.


- Elec.W.diagram : COL 1C, 3C, 4A

Reference - MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input[0] "MC2I"


- MCU HHT : 1.IN/OUT>>1.2 PIO Output>>PIO Output[0] "MC2"
- Check "MC2" contacts have welded or not
Check

- Check "MC2" contactor connection.

Point

- Check "MCX2" relay of TNP board.


- Check PIO board.

Rev. Commemts :

HELCO-C5-003-01

- 12 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F71

HSVF Trouble manual


Document Number :

Safety Line Error (While Running)


- Safety line error (when elevator is running).

State

- Impossible to move in inspection, auto operation and etc.,


- Elec.W.diagram : COL 3A, 3B, 3C, 4A

Reference

- MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input[0] "29"


- Check power supply DC110V, DC24V.

Check
Point

- Check X29 Relay of TNP board.


- Check switches of safety line.
- Check HHT 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 29
- Check H2,H3 cable between PIO board and TNP board.

F81

Watchdog Error
- MCU board fault

State

- Impossible to move in inspection, auto operation and etc.,

Reference - MCU "WDOG" LED


Check
Point

- Repair the MCU board

F91

State

MCU Board Reset


- Displayed at that time of booting the MCU board

Reference - None

Check
Point

- Check power supply AC 220V.


- Check power input connector "CM1" of MCU board. (DC 5V)
- Check the push button "RESET"

Rev. Commemts :

HELCO-C5-003-01

- 13 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F12

HSVF Trouble manual


Document Number :

MT_Thermal / CCS Switch Error


- Motor thermal activates in running F12 move to near door zone
- Compensation chain switch activates in running F12 occurs

State

move to near door zone


- Possible to move in inspection.
- Elec.W.diagram : COL 4A (CCS/MT)

Reference
Check
Point

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] MT
- Check TH1,THC with tester.
- Check MT relay.
- Check CCS switch.

F22

Floor data Error


- Floor data error in auto operation.

State

- Impossible to move in auto operation.


- Floor data error between MCU and inverter
- Elec.W.diagram : COL 1A, 1B, 1C

Reference - MCU HHT : 3.SETUP>>3.1Basic>>31b Field>>B01 Total FL Num


- inverter HHT : PROGRAM>>CONTROL>>MAX FLOOR
Check

- Check floor data between MCU and inverter.

Point

- Check DPRAM cable, shield and ground.

F42
State

Initialization Error
- After initialization, inverter don't output high operation signal to MCU.
- Elec.W.diagram : COL 3A, 3B
- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] ULS, DLS

Reference

- Inverter HHT : MONITOR>>BASIC>>INIT OK


: PROGRAM>>CONTROL>>MAX FLOOR

Check
Point

- Check the door zone sensor input.


- Check the floor data of inverter "MAX FLOOR".
- Check the limit switch position.

Rev. Commemts :

HELCO-C5-003-01

- 14 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F52

HSVF Trouble manual


Document Number :

Pulse Error
- Pulse compensation error (500mm) in auto operation.

State

- F42 move to near door zone


- Elec.W.diagram : COL 4A

Reference - MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] ULA, DLA
- Inverter HHT : MONITOR>>FLOOR DATA>>CURRENT POSITION
Check
Point

- Check the door zone sensor input.


- Check the floor data of inverter "MAX FLOOR". ?
- Check the limit switch position.

F62

Vane Count Error


- In initialization, the number of door vane is different from total floor data.

State

- Possible to move in inspection.


- Elec.W.diagram : COL 3A, 3B, 4A

Reference - MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] ULS, DLS
- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] DLA,DZ,ULA
Check
Point

- Check the door vane and sensor input.


- Check the floor data of inverter "MAX FLOOR".
- Check the limit switch position.

F72
State

Long Creeping Error


- Creeping time is over 15 seconds in auto operation
- Elec.W.diagram : COL 3A, 3B

Reference - MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0]
PLUH, PLDH, PLUM, PLDM
Check
Point

- Check the limit switch position.


- Check the limit switch signal.
- Redo the initialization

Rev. Commemts :

HELCO-C5-003-01

- 15 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

F13

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

OPB Line disconnection Error


- OPB line disconnection error

State

- Possible to move in inspection.

Reference - MCU HHT : 1.IN/OUT>>1.D CAN Status>>CAN.Car Status


Check
Point

- Check the OPB line and OPB board.


- HHT "CAN.Car Status" : 0x000000** (normal)
: 0x800000** (abnormal)

F23

OPB bus off Error


- MCU commands to stop communication as noise.

State

- Possible to move in inspection.

Reference - MCU HHT : 1.IN/OUT>>1.D CAN Status>>CAN.Car Status


Check

- Check line noise and OPB board.

Point

- Check ground condition of machine room.

F43

PCB WatchDog Error


- In stopping condition, F43 set. impossible to move in auto operation.

State

- Possible to move in inspection.

Reference - None
Check
Point

- Repair or update the OPB-340 board,

F63

OPB Communication Error


- OPB line is correct, but communication data error occurs.

State

- Possible to move in inspection.

Reference - MCU HHT : 1.IN/OUT>>1.D CAN Status>>CAN.Car Status


Check

- Check communication line and OPB board.

Point

- Check OPB board dip switch. (all dip switches must be off)

Rev. Commemts :

HELCO-C5-003-01

- 16 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

F83
State

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

OPB Communication Error (Penetration Type)


- all communication signal of rear OPB are none

Reference - MCU Bd HHT : 5. REAR/INFO >> 5.1 Version >> 51f OPB.2
Check
Point

- Check rear OPB ID (DIP Switch 4 on, 3~1 off)


- Check rear OPB LD1 (LED flickering) and LD2 (DC 24V)
- MCU Bd HHT : 3. SETUP >> 3.2 Device >> 32a OPB2. USE

Rev. Commemts :

HELCO-C5-003-01

- 17 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

F14

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

Door Error (In running)


- Interlock switch or gate switch is not on while elevator running.

State

- F14 impossible to move in any operation.


- Elec.W.diagram : COL 3A, 3B, 3C, 4A

Reference
Check
Point

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 40, 41
- Check hatch door interlock switch and gate switch.
- Check "CT4", "CT5" connectors status of TNP board.
- Check "X40", "X41" relays status of TNP board.

F24
State

Door Jumper Error


- Interlock or gate switch jumper when car door is open fully.
- Elec.W.diagram : COL 3A, 3B, 3C, 4A

Reference - MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 40, 41
- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DOL, DCL
Check
Point

- Check hatch door interlock switch and gate switch.


- Check "CT4", "CT5" connectors status of TNP board.
- Check "X40", "X41" relays status of TNP board.

F34
State

DCL Error
- No "DCL" signal input after trying to close 3 times.
- Elec.W.diagram : COL 6A, 6B, 6C

Reference
Check
Point

- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DCL
- Check "DCL" signal and sensor state.
- Check door sill and obstacles.
- Check "CC13" connector of CCB-7 board.

Rev. Commemts :

HELCO-C5-003-01

- 18 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F44

HSVF Trouble manual


Document Number :

Door Open Error


- After trying to open 3 times, MCU commands to move E/L for next floor.
- And if E/L can't open the door again, MCU commands to move E/L

State

for lobby.
- Then F44 error occurs.
- Elec.W.diagram : COL 6A, 6B, 6C

Reference
Check
Point

- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DOL
- Check "DOL" signal and sensor state.
- Check door sill and obstacles.
- Check "CC13" connector of CCB-7 board.

F54

Door Close Error (before E/L start to move)


- Interlock, gate, DCL signal fault before E/L start to move

State

- F54 cancel calls open, close


- Elec.W.diagram : COL 3A, 3B, 3C, 4A, 6A, 6B, 6C

Reference - MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 40,41
- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DCL
Check
Point

- Check "DCL" signal and sensor state.


- Check "CT4", "CT5" connectors status of TNP board.
- Check "X40", "X41" relays status of TNP board.

F64

Door Open Error (Penetration Type)


- Front door opened at rear door zone in condition of arrange mode

State

- Rear door opened at front door zone in condition of arrange mode


- Elec.W.diagram : COL 6C
- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] FDZ,RDZ

Reference

- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [0] DCL
- MCU HHT : 1.IN/OUT >> 1.3 Car Input >> CarSigIn [2] RDCL
- Check "DCL,RDCL" signal and sensor state.
- Check "FDZ, RDZ" signal and door zone sensor state.

Check

- MCU Bd HHT : 3.SETUP >> 3.1 Basic >> 31c Nonstop >> C03,C04

Point

FronNonStp
- MCU Bd HHT : 3.SETUP >> 3.1 Basic >> 31c Nonstop >> C05,C06
RearNonStp

Rev. Commemts :

HELCO-C5-003-01

- 19 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

F74

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

Abnormal Running Error (in a state of door open)


- E/L moves to a out of door zone without "FWD,REV" signal.

State

- F74 sub brake activated (RBK off) stop


- Impossible to move in any operation
- Elec.W.diagram : COL 3A, 3B, 4B, 4C

Reference - MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] RBKI
- MCU HHT : 4.MANAGEMENT >> 4.3 FieldTest >> 43b RopeBrkReset
- Check the lining state of brake.
Check
Point

- Check the brake spring setting.


- Check the gate and hatch interlock switch while E/L is running.
- Check "CT51" connector of TNP board. (RBKIN)
- Cancel F74 : MCU HHT "43b RopeBrkReset" 0x00

F84

MC1 Contactor Stuck (After F74 Error)


- Though F74 Error happened, "MCI" signal is not off as MC1 contactor
stuck.

State

- Impossible to move in any operation.


- Elec.W.diagram : COL2A, COL2B, COL3C, COL4A
Reference - MCU Bd HHT : IN/OUT / PIO Input / PIO Input [0] "MCI"
- MCU Bd HHT : IN/OUT / PIO Output / PIO Output [0] "MC1"
Check
Point

- Check MC1 contactor condition


- Check PIO Output [0] "MC1" signal off
- Check PIO Input [0] "MCI" signal off

F94

Impossible To Move After Door Error (In running)


- Interlock switch or gate switch is not on while elevator running.

State

- F94 impossible to move in any operation. (Russian national code)


- Elec.W.diagram : COL 3A, 3B, 3C, 4A
- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] 40, 41

Reference

- MCU HHT : 3.SETUP >> 3.1 Basic >> 31b Field >> B46 BuzzerOption >>
F94 Enable

Check
Point

- Check hatch door interlock switch and gate switch.


- Check "CT4", "CT5" connectors status of TNP board.
- Check "X40", "X41" relays status of TNP board.

Rev. Commemts :

HELCO-C5-003-01

- 20 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

F15

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

Inverter Error (30B)


- Abnormal state of inverter (30B off) in spite of MCU output reset signal
5 times at 2 second interval.

State

- F15 MC1 off impossible to move in any operation.


- Elec.W.diagram : COL 1A, 1B, 1C
Reference
Check
Point

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] 30B
- Connect HHT to inverter and check inverter error.
- Check "H9" connector of TNP board.
- Check the 3-phase power. (R,S,T)

F25

Dynamic Braking Error


- Despite no command, E/L moves upward or downward

State

MCU commands to brake off continuously


And dynamic braking (output "FWD" for 1 second) F25
- Elec.W.diagram : COL 1A, 1B, 1C, 2A, 2B, 2C

Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] ZSP
- Check the lining state of brake.

Check

- Check the brake spring setting.

Point

- Check the obstacles in brake.


- Check the noise in the motor encoder.

F35

Inverter Setting Error


- Despite no command, "RUN" or "BKS" signal of inverter is turned on .

State

- Impossible to move in any operation.


- Elec.W.diagram : COL 1A, 1B, 1C

Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] ZSP,BKS,30B

Check

- Check the all data of inverter.

Point

- Check "CN12" of Inverter and "H9" connector of TNP board.

Rev. Commemts :

HELCO-C5-003-01

- 21 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F45

HSVF Trouble manual


Document Number :

Inverter Run Signal Error


- At the time to start, there is no "RUN" signal of inverter F45 occurs

State

- Impossible to move in any operation.


- Elec.W.diagram : COL 1A, 1B, 1C

Reference - MCU HHT : 1.IN/OUT>>1.2 PIO Output>>PIO Output [0] FWD,REV


- MCU HHT : 1.IN/OUT>>1.1 PIO Input>>PIO Input [2] RUN
Check
Point

- Check "H9" connector of TNP board and "CN12" connector of inverter.


- Check "FWD,REV" in MCU HHT
- Check "F,R" in inverter HHT "MONITOR >> I/O"

F55
State

Speed Disagreement Error


- Inverter output speed disagreement error while E/L is running.

Reference - Elec.W.diagram : COL 1A, 1B, 1C


- Check the motor encoder and encoder line noise.
Check
Point

- Check the data of inverter HHT.


- Check the connection of U,V,W between inverter and motor.
- Check the balance between cage and counter weight.
- Check another errors of MCU and inverter.

F65

Inverter ZSP Error


- At the time to start, "ZSP" signal is turned on and E/L can't move
for 5 seconds.

State

- F65 occurs Possible to move in any operation.


- Elec.W.diagram : COL 1A, 1B, 1C
Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] ZSP
- Check the motor encoder and encoder line.

Check

- Check "H9" connector of TNP board and "CN12" connector of inverter.

Point

- Check inverter HHT "MONITOR >> I/O".


- Check inverter HHT "PROGRAM >> INTERFACE >> Zero Speed Level"

Rev. Commemts :

HELCO-C5-003-01

- 22 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F75
State

HSVF Trouble manual


Document Number :

Inverter Error (In running)


- Abnormal state of inverter (30B off) while E/L is running.
- Elec.W.diagram : COL 1A, 1B, 1C

Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] 30B

Check

- Check the inverter HHT "MONITOR >> ERROR"

Point

- Check "H9" connector of TNP board and "CN12" connector of inverter.

F16

Brake Open Error (F26 twice)


- MCU commands to open brake, but brake can't be operated.
"BKOP(Brake confirm switch)" isn't activated.

State

"RBKIN(sub brake confirm signal)" isn't activated.


- F26 twice F16 occurs
- Elec.W.diagram : COL 2A, 2B, 2C, 3A, 3B, 4B, 4C

Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] BKOP,RBKI
- Check the brake line power and connection.

Check
Point

- Check the "BKOP" switch and connection with MCU HHT.


- Check the "CT3B" connector of TNP board.
- Check the "RBKIN" line and connection in case of appling sub brake.
- Check the "CT51" connector of TNP board.

F26

Brake Open Error


- Same as F16

State

- F26 twice F16 occurs


- Elec.W.diagram : COL 2A, 2B, 2C, 3A, 3B, 4B, 4C

Reference
Check
Point

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] BKOP,RBKI
- Same as F16

Rev. Commemts :

HELCO-C5-003-01

- 23 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

F36

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

Brake activation Error


- Despite no command, "BKOP(Brake confirm switch)" is activated

State
Reference
Check
Point

- F36 occurs buzzer on


- Elec.W.diagram : COL 3A, 3B
- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] BKOP
- Check the "BKOP" switch setting.
- Check the obstacles in brake.
- Check the "BKOP" line and connection.

F46

Brake Contactor Stuck Error


- In spite of MCU commands to turn brake off, brake contact can't be off.

State
Reference
Check
Point

- Impossible to move in any operation.


- Elec.W.diagram : COL 4A
- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] BKB
- Check "BKB" contacts have welded or not
- Check brake contactor(BKB) and its connection.
- Check "BRB" relay of TNP board.

F56
State

Car Brake Input Error


- No car brake input in inspection or auto operation.
- Elec.W.diagram : COL 3A, 3B, 4B

Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] RBKI

Check

- Check the car brake state.

Point

- Check the "CT51" connector fo TNP board.

F66

MC2 Contactor Off Error (In running)


- No "MC2" contactor input in inspection or auto operation.

State
Reference
Check
Point

- Possible to move in any operation.


- Elec.W.diagram : COL 4A
- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] MC2I
- Check the "MCX2" relay of TNP board.
- Check the MC2 contactor and its connection.
- Check the "CT55" connector of TNP board.

Rev. Commemts :

HELCO-C5-003-01

- 24 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F76

HSVF Trouble manual


Document Number :

PDLS Error
- "PDLS" signal of CT54 in TNP board is always on.

State

- Impossible to move in any operation.


- Elec.W.diagram : COL.3B

Reference
Check
Point

- MCU Bd HHT : IN/OUT / PIO Input / PIO Input [1] PDLS"

- Remove the jumper connector of CT54 in TNP board

F17

ULS/DLS Off Error


- No "ULS/DLS" signal input at the same time

State

- Impossible to move in any operation.


- Elec.W.diagram : COL 3A, 3B

Reference

Check
Point

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] ULS, DLS
- Check the limit switch "ULS, DLS" and its connection.
- Check "CT1", "CT2" connector of TNP board.
- Check the MCU HHT data "PIO Input[0]>>ULS,DLS".

F27

PLU/PLD Off Error


- No "PLU/PLD" signal input at the same time

State

- Impossible to move in any operation.


- Elec.W.diagram : COL 3A, 3B, 10A, 10B

Reference - MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0]
PLUL, PLUH, (PLUM), (PLDM), PLDH, PLDL
Check
Point

- Check the limit switch "PLUL, PLUH, (PLUM), (PLDM), PLDH, PLDL"
and its connection.
- Check "CT1", "CT2" connector of TNP board.

Rev. Commemts :

HELCO-C5-003-01

- 25 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F37

HSVF Trouble manual


Document Number :

Door Zone Sensor Error


E/L can't be arrived to door zone for 15 seconds after deceleration.

State

ULA/DLA on, DZ off


ULA/DLA off, DZ on
- Elec.W.diagram : COL 4A, 7A

Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] "ULA, DZ, DLA"
- Check the door zone sensor input "ULA, DZ, DLA" and its connection.

Check
Point

- Check the "T1" harness of TNP board and CCB-7 board.


- Check the door zone vane state.
- Check the inverter errors and HHT floor data.
- Check the "DZ" connection of EPB-100 board. (in case of SSVF7)

F47
State

Relevel Landing Error


- Out of door zone in door open relevel landing operation
- Elec.W.diagram : COL 4A

Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [2] "ULA, DLA"
- Check the door zone sensor input "ULA, DZ, DLA" and its connection.

Check
Point

- Check the "T1" harness of TNP board and CCB-7 board.


- Check the gap between door zone sensors. (135mm)
- Check the door zone vane and its length. (300mm)
- Check inverter data "PROGRAM>>CONTROL>>RELEVEL RPM".

F57
State

ULS/DLS Error (In running)


- "ULS" or "DLS" limit switch activated in running.
- Elec.W.diagram : COL 3A, 3B, 10A, 10B

Reference

Check
Point

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "ULS, DLS"
- Check the limit switch "ULS, DLS", its connection and position.
- Check "CT1", "CT2" connector of TNP board.
- Check the MCU HHT data "PIO Input[0]>>ULS,DLS".

Rev. Commemts :

HELCO-C5-003-01

- 26 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

F67

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

PLU/PLD Error (Deceleration Fault)


- "PLUL" or "PLDL" limit switch activated in auto operation

State

without deceleration.
- Elec.W.diagram : COL 3A, 3B, 10A, 10B

Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "PLUL, PLDL"
- Check the limit switch "PLUL, PLDL" and its position.

Check

- Check "CT1", "CT2" connector of TNP board.

Point

- Check the inverter errors and floor data. (MONITOR>>FLOOR DATA)


- Do Initializating operation again.

F77

PLUL/PLDL Error (Floor Confirm Error)


- No PLUL switch input at top floor in auto operation.

State

- No PLDL switch input at bottom floor in auto operation.


- Elec.W.diagram : COL 3A, 3B, 10A, 10B

Reference
Check
Point

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "PLUL, PLDL"
- Check the limit switch "PLUL, PLDL" and its position.
- Check "CT1", "CT2" connector of TNP board.
- Check the inverter errors and floor data. (MONITOR>>FLOOR DATA)

F87

Door Sensor Detected Error (UPDOOR + 1BC + E/L for Car)


- Detected door sensor "SE, RSE" in auto running.

State

- Impossible to move in any operation.


- Elec.W.diagram : COL 4A

Reference -. MCU Bd HHT : IN/OUT / Car Input / Car Input [0] SE"
-. MCU Bd HHT : IN/OUT / Car Input / Car Input [2] RSE"
Check
Point

- Check door sensor signal and line of "SE, RSE".

Rev. Commemts :

HELCO-C5-003-01

- 27 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F18

HSVF Trouble manual


Document Number :

Group Communication Error


communication error in ring group

State

GIO board error in duplex group


- both , are possible to move in auto single operation.
- Elec.W.diagram : COL 18A, 18B
- MCU HHT :

Reference

3.SETUP>>3.1 Basic>>31b Field>>B23 Group Mode


1.IN/OUT >> 1.C Group Output >>C24 GOFLAG[7]>>"0x81"
- Check MCU HHT data.

Check

- Check the state whether in auto operation or not.

Point

- Check GIO board connection of MCU board.


- Check GIO board LED state. (refer to "STVF7 ADJUSTMENT MANUAL")

F28

RMS Communication Error


- RMS(Remote Monitoring System) communication error

State

- Possible to move in any operation.


- Elec.W.diagram : COL 7B

Reference

- MCU HHT : 3.SETUP>>3.1 Basic>>31b Field>>B22 RMS use>>"Enable"

Check

- Check "H1" connector of MCU board.

Point

- Check the power supply of RMS board.

F38

RNBL Error
- "RNBL(Run-By-Limit)" switch is activated while E/L is running.

State

- F38 occurs buzzer on


- Possible to move in any operation
- Elec.W.diagram : COL 3B

Reference

- MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [1] "RNBL"

Check

- Check the "RNBL" switch connection.

Point

- Check the main rope tension.

Rev. Commemts :

HELCO-C5-003-01

- 28 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F48

State

HSVF Trouble manual


Document Number :

Water Over Error


- Detected water sensor "WLS" in the pit.(for Lower-Driven MRL)
- Elec.W.diagram : COL 3B

Reference

Check
Point

- MCU Bd HHT : IN/OUT /PIO Input /PIO Input [1] "WLS

- Check the water sensor "WLS" signal and its lines.

F58

LS Board Communication Error


- LS board communication error in case of "LXVF7, SSVF7"

State

- Possible to move in any operation


- Elec.W.diagram : COL 7A

Reference

Check
Point

- MCU HHT : 3.SETUP>>3.1 Basic>>31a General>>A20 Load Sensor


- Check the LS board connection.
- Check the CAN communication line between OPB and LS board.
- Check the "JU1" jumper pin of OPB board. (short)

F68

Hall Communication Error


- Hall-CAN board communication error

State

- Possible to move in any operation


- Elec.W.diagram : COL 8A, 11A, 11B

Reference

- MCU HHT : 2.ERROR>>2.3Hall Error>> HallErr.1, HallErr.2


- Check MCU HHT : 2.ERROR>>2.3Hall Error>> HallErr.1, HallErr.2

Check

- Check the communication line.

Point

- Check the Hall-CAN board state and dip switch adjustment.


(refer to "STVF7 ADJUSTMENT MANUAL)

Rev. Commemts :

HELCO-C5-003-01

- 29 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

F78

HSVF Trouble manual


Document Number :

MC2 Contactor Error (At starting)


- No "MC2" contactor input at starting in case of SSVF7

State

- Impossible to move in any operation


- Elec.W.diagram : COL 1C, 3C, 4A

Reference - MCU HHT : 1.IN/OUT >> 1.1 PIO Input >> PIO Input [0] "MC2I"
- MCU HHT : 1.IN/OUT >> 1.2 PIO Output >> PIO Output [0] "MC2"
Check
Point

- Check the "MCX2" relay of TNP board.


- Check "MC2" contactor connection.
- Check "CT55" connector of TNP board.

F59

LS Setting Error
- No LS setting in case of LXVF7 and SSVF7

State

- Possible to move in any operation


- Elec.W.diagram : COL 7A

Reference

- MCU HHT : 3.SETUP>>3.1 Basic>>31a General>>A20 Load Sensor


- Do LS board setting according to "STVF7 ADJUSTMENT MANUAL"
HHT : 20a LS Use "Enable"
20c Sensing Data 9000~10000 (check LS sensor position)
load 0% in cage

Check
Point

HHT : 20b Load Setting>>0% "settable"


(check in door zone and inspection switch in Machine room)
HHT : 0% >> "YES" enter "waiting"
0% setting end (buzzer)
load 50% in cage
HHT : 50% >> "settable"

"YES" enter "waiting"

50% setting end (buzzer twice)

Rev. Commemts :

HELCO-C5-003-01

- 30 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

F69

State

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

RTC Error
- Time Setting fault or time chip fault of MCU board

- MCU Bd HHT : 3. SETUP >> 3.3 Time & Date >> 33a Time set
Reference

- MCU Bd HHT : 3. SETUP >> 3.3 Time & Date >> 33b Date set

Check

- Check the mercury cell voltage (DC 3V).

Point

- Set the time and date with HHT.

Rev. Commemts :

HELCO-C5-003-01

- 31 -

A4(210297)

Hyundai Elevator Co., Ltd.

HSVF SYSTEM
File Name :

TITLE

REV.0

2011.12.23

HSVF SERIES
TROUBLESHOOTING MANUAL

HSVF Trouble manual


Document Number :

Rev. Commemts :

HELCO-C5-003-01

- 32 -

A4(210297)