For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
NEC/ CEC:
NEC:
Class I, Division 2, Groups A, B, C, D
Marine Outside Type (Salt Water)
Class I, Zone 2 AEx nA IIC, Ex nA IIC
Wet Locations
Type 3R, 4, 4X
IP66/ 67
ATEX/IECEx:
II 3 G
Ex nA IIC T4 Gc
Ta -25 C to +40 C
(-13 F to +104 F)
IP66
NBR IEC:
Zone 2 21 and 22
Ex nA IIC Gc
Ex t b IIIC Db
IP66
Applications
Typical applications include:
Pulp and paper mills
Processing plants
Chemical plants
Oil reneries
Foundries
Food processing plants
Storage areas
Waste and sewage treatment
Parking garages
Other areas where water, dirt and rough usage are a problem
Features
Standard Materials
Standard Finishes
Housing, lens cover and yoke mount: architectural bronze
polyester
Floodlight
Lighting LED
High Bay
1425
NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE AND ATEX/IEC/NBR IEC RATED FLOODLIGHT
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
NEC/ CEC:
NEC:
Class I, Division 2, Groups A, B, C, D
Marine Outside Type (Salt Water)
Class I, Zone 2 AEx nA IIC, Ex nA IIC
Wet Locations
Type 3R, 4, 4X
IP66/ 67
ATEX/IECEx:
II 3 G
Ex nA IIC T4 Gc
Ta -25 C to +40 C
(-13 F to +104 F)
IP66
NBR IEC:
Zone 2 21 and 22
Ex nA IIC Gc
Ex t b IIIC Db
IP66
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide NEC/CEC Certified Areamaster LED
AMLED
Series:
AMLED: Areamaster LED Series
NEC/CEC Certified
Light Pattern
BU1
FN
Voltage:
BU1 - 120-277 Vac,
50/60 Hz
BH - 347-480 Vac,
50/60 Hz
BC - 250 Vdc
Mounting:
Y - Yoke Mount
C - Chain Mount
Options:
FN - Fuse for BU1 or
BH Voltages
D - Diffused
Polycarbonate
Lens
Lighting LED
Catalog Numbering Guide ATEX/IECEx and NBR IEC Brazilian Certified Areamaster LED
AMLED
Series:
AMLED: Areamaster LED Series
ATEX/IECEx Certified
Light Pattern
BK
Voltage:
BK - 220-240 Vac,
50/60 Hz
Mounting:
Y - Yoke Mount
C - Chain Mount
1426
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
NEC/ CEC:
NEC:
Class I, Division 2, Groups A, B, C, D
Marine Outside Type (Salt Water)
Class I, Zone 2 AEx nA IIC, Ex nA IIC
Wet Locations
Type 3R, 4, 4X
IP66/ 67
ATEX/IECEx:
II 3 G
Ex nA IIC T4 Gc
Ta -25 C to +40 C
(-13 F to +104 F)
IP66
NBR IEC:
Zone 2 21 and 22
Ex nA IIC Gc
Ex t b IIIC Db
IP66
Technical Data
NEC/CEC
Gas
Lamp
Catalog
Number
Line Voltage
Ambient
Supply Wire
Temperature Temperature
Class I,
Type
C (F)
C (F)
Division 2
Dust
Groups
ExnA IIC
AExnA IIC
Class II,
Division 1
Groups E,F,G
ExII3G
ExnA
Subdivision
75 (167)
T4
A,B,C,D
T4
55 (131)
90 (194)
T3C
A,B,C,D
T3
65 (149)
90 (194)
T3C
A,B,C,D
T3
40 (104)
75 (167)
T4
A,B,C,D
T4
40 (104)
75 (167)
T4
A,B,C,D
T4
55 (131)
90 (194)
T3C
A,B,C,D
T3
65 (149)
105 (221)
T3C
A,B,C,D
T3
40 (104)
75 (167)
T4
A,B,C,D
T4
AMLED77YBK
220-240 Vac LED
NAMLED77YBK
40 (104)
60 (140)
T4
A,B,C,D
T4
T4
IIC
40 (104)
75 (167)
T4A
A,B,C,D
T4
40 (104)
75 (167)
T3C
A,B,C,D
T3
55 (131)
90 (194)
T3A
A,B,C,D
T3
AMLED77YBC
250 Vdc
LED
Lighting LED
40 (104)
T1
350
325
T2
T2A
T2B
T2C
NEC/CEC
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
Temp.
Range
(C)
351450
326350
301325
281300
261280
231260
216230
201215
181200
166180
161165
136160
121135
101120
86100
85
Temp.
Range
(F)
664842
619662
574617
538572
502536
448500
421446
394419
358392
331356
322329
277320
250275
214248
18712
185
T
Number
T
Number
T2
T3
T4
T5
T6
Temp.
Range
(C)
301-450
201-300
136-200
101-135
86-100
85
Temp.
Range
(F)
547-842
394-572
277-392
214-275
187212
185
T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC.
T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 1 and Class I, Zone 2 as designated by the NEC or Zone 2
(Gas) and 22 (Dust) locations as designated by the IEC.
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
May 2014
NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE AND ATEX/IEC/NBR IEC RATED FLOODLIGHT
1427
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
NEC/ CEC:
NEC:
Class I, Division 2, Groups A, B, C, D
Marine Outside Type (Salt Water)
Class I, Zone 2 AEx nA IIC, Ex nA IIC
Wet Locations
Type 3R, 4, 4X
IP66/ 67
ATEX/IECEx:
II 3 G
Ex nA IIC T4 Gc
Ta -25 C to +40 C
(-13 F to +104 F)
IP66
NBR IEC:
Zone 2 21 and 22
Ex nA IIC Gc
Ex t b IIIC Db
IP66
Catalog Number
Voltage Range
Frequency ( Hz)
Watts
Input Power
(Nom.)
AMLED67YBU1
120-277 Vac
50/60
76/74
0.64 - 0.32
0.5
> 0.98
AMLED67YBH
347-480 Vac
50/60
76/76
0.22 - 0.16
0.5
> 0.96
AMLED77YBU1
120-277 Vac
50/60
125/121
1.10 - .047
0.5
> 0.98
AMLED77YBH
347-480 Vac
50/60
120/119
0.35 - 0.25
0.5
> 0.96
AMLED77YBK
NAMLED77YBK
220-240 Vac
50/60
117
0.53 - 0.48
0.5
> 0.98
AMLED77YBC
250 Vdc
118
0.47
0.5
> 0.98
AMLED87YBU1
120-277 Vac
50/60
174/169
1.60 - 0.70
0.5
> 0.98
NEC/CEC
Catalog Number
ATEX/IECEx
NBR IEC
Input Amps
(Max.)
Total Harmonic
Distortion
Power Factor
Lighting LED
NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE AND ATEX/IEC/NBR IEC RATED FLOODLIGHT
Line Voltage
120-277 Vac, 50/60 Hz
AMLED67YBU1
AMLED77YBU1
AMLED87YBU1
AMLED67YBH
AMLED77YBH
250 Vdc
AMLED77YBC
AMLED77YBK
NAMLED77YBK
1428
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
Description
Crossarm Mounting Bracket
Has 180 horizontal adjustment degree marked. Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
G-AM-8-CA
NGAM8CA
G-AM-8-WB
NGAM8WB
Slip-fits 1-1/2 or 2 pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.
G-SF20
Slip-fits 1" or 1-1/2 pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.
AMLEDSF1
G-AM-8-SF
Chain mount assembly comes with two (2) 914.4 mm (36 inch) long chains,
four (4) eye bolts, four (4) hex bolts, four (4) lock washers, four (4) hex nuts,
eight (8) plain washers and an instruction sheet for complete assembly and
mounting. Chains are galvanized steel, eye bolts are zinc plated steel, all other
hardware is stainless steel.
AMLEDCM
Poletop Slip-Fitter
Lighting LED
Poletop Slip-Fitter
Chain
Description
NEC/CEC
NAMLEDCM
Catalog Number
ATEX/IEC
NBR IEC
LED Array
With White LED's for the AMLED67
AMLED67AW
AMLED77AW
AMLED87AW
AMLED77DBU
120 - 277 Vac BU1 Version AMLED87: Left Side AMLED67, AMLED77
AMLEDDBU1L
AMLEDDBU1R
AMLED77DBK
AMLED77DBH
AMLED77AW
NAMLED77AW
Drivers
AMLED77DBK
NAMLED77DBK
Door Assembly
With a Glass Lens, Pins
AMLEDMDOOR
AMLEDMDOORP
AMLEDMDOOR NAMLEDMDOOR
NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE AND ATEX/IEC/NBR IEC RATED FLOODLIGHT
1429
NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE AND ATEX/IEC/NBR IEC RATED FLOODLIGHT
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
4645.2 mm2
(7.20 in2)
358.1 mm
(14.10 in)
Conduit
Entry
(Pendant
Mount)
391.2 mm
(15.40 in)
Set
Screw 144.78 mm
(5.70 in)
57.2 mm
(2.25 in)
Conduit
Entry
Yoke
3.64 Turning Radius
180 Rotation
122.7 mm 88.9 mm
(4.83 in) (3.50 in)
Lighting LED
44.45 mm
(3) Mounting Holes
(1.75")
14 mm (0.56 in)
88.9 mm (3.50 in)
1430
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
ISOCANDELA CURVES
3
2
0.1 fc
0.5 fc
1
1250
2.5 fc
0
2500
2696
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
% Fixture
3.0
9.4
17.4
22.4
21.7
17.6
8.1
0.5
0.1
1 fc
NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE AND ATEX/IEC/NBR IEC RATED FLOODLIGHT
0.2 fc
2
3750
0
Lighting LED
1250
2500
2696
3750
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
% Fixture
2.9
9.2
17.1
22.2
21.4
17.8
8.8
0.6
0.0
1431
NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE AND ATEX/IEC/NBR IEC RATED FLOODLIGHT
Lighting LED
HOR.
0
21
26
700
2400
3023
3375
3838
4312
4670
4964
4910
4700
4456
4273
4184
4154
4139
4124
4127
4138
4149
4149
0
2
5
733
2341
2976
3307
3826
4319
4719
4898
4857
4660
4343
4249
4165
4123
4105
4119
4133
4150
4153
4149
1432
90
81.8
60
2909
30
1250
2500
-30
-60
3750
-90
30
60
90
Spacing
Criteria
1.5
1.5
Lumens
98
290
485
711
993
1264
1440
1517
1471
1392
1283
1086
764
340
37
4
2
1
ISOCANDELA CURVES
VERT.
Lamps: Areamaster, High Bay Mount, LED Board 56 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered
To 3-1/2 X 3-1/2, Lens Clear
1250
2500
% Ceiling Rcc
% Walls Rw 70
0 119
1 111
2 102
3
94
4
86
5
79
6
73
7
67
8
63
9
58
10
55
3750
Zone
0-30
0-40
0-60
0-90
90-120
Lumens
3841
6798
12029
13177
1
% Lamp
N.A.
N.A.
N.A.
N.A.
N.A.
10
106
93
79
68
59
51
45
39
35
31
28
50
102
93
83
75
67
60
54
49
45
42
38
% Lamp
N.A.
N.A.
N.A.
N.A.
10
30
102
92
80
70
62
55
49
44
39
36
32
0
10 0
102 100
90 88
78 76
67 65
58 56
50 48
44 42
39 37
35 33
31 30
28 27
% Fixture
0.0
0.0
0.1
100
NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE AND ATEX/IEC/NBR IEC RATED FLOODLIGHT
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
0
5
8
938
3477
4345
4831
5752
6392
6778
7087
7158
6664
6222
6108
6044
5942
5938
5956
5975
5995
6004
5999
90
581.8
60
2909
30
2023
4046
-30
6069
-60
-90
8092
30
60
Horizontal Angles
90
Spacing
Criteria
1.54
1.54
Lumens
141
419
697
1004
1408
1794
2079
2151
2143
2011
1834
1567
1118
514
62
3
2
1
ISOCANDELA CURVES
Lighting LED
90
85
75
65
55
47.5
42.5
37.5
33
29
25.5
22.5
19.5
17
15
13
11
9
7
5
3
1
0
Vertical Angles
DEG.
Lamps: Areamaster, High Bay Mount, LED Board 20 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered
To 3-1/2 X 3-1/2, Lens Clear
2500
5000
% Ceiling Rcc
% Walls Rw 70
0 119
1 111
2 102
3 93
4 86
5 79
6 73
7 67
8 63
9 58
10 54
7500
Zone
0-30
0-40
0-60
0-90
90-120
Lumens
5462
9692
17247
18946
2
% Lamp
N.A.
N.A.
N.A.
N.A.
N.A.
10
106
93
79
68
58
51
45
39
35
31
28
50
102
93
83
74
67
60
54
49
45
41
38
% Lamp
N.A.
N.A.
N.A.
N.A.
10
30
102
91
80
70
62
55
49
43
39
35
32
10
102
90
77
67
58
50
44
39
35
31
28
0
0
100
88
75
65
56
48
42
37
33
29
26
% Fixture
0
0
0
100
1433