Professional Documents
Culture Documents
Main Contents
Features
Working principles
Improvements from BA-88
Competitors
Operation
Price
FAQ
Features
Cuvette
Main Interface
Parameter Setup
Testing Panel
Easy Maintenance
Easy Maintenance
Pump
1. long life (almost no need to change);
2. extra pump tube
3. pump calibration every ~2 months
Flowcell
1. easy to be observed when results
susceptible; easy to locate the
problem
2. easy to be installed/replaced
Easy Maintenance
Software upgrade
- via USB; easy and quick
filter replaced
Main Contents
Features
Working principles
Improvements from BA-88
Competitors
Operation
Price
FAQ
Working principles
Structure layout
Thermal printer
Touch screen
Aspirate button
Structure layout
Main Contents
Features
Working principles
Improvements from BA-88
Competitors
Operation
Price
FAQ
BA-88
a. Testing mode(s)
flowcell or cuvette
flowcell
b. Connection ports
RS232 and two USBs only RS232 serial
(for mouse, keyboard, port
printer or upgradation)
c. Display
Large TFT touch
screen (7.0);
true-color;
higher resolution
BA-88
d. Software operation
Pop-up or external keyboard Letter-choose type input;
to input; scroll up/down
page up/down
e. Power failure protection
Yes, all finished data saved No, possibility of losing data
when unfavorable power-off when power off
BA-88
h. Patient report
Patient information customizable
and printable; offsystem/calculation tests can be
added into report
And much more
670nm wavelength; self gain
adjustment; more comprehensive
QC functions; ...
Main Contents
Features
Working principles
Improvements from BA-88
Competitors
Operation
Price
FAQ
BA-88A vs RT-1904c
BA-88A
BAa. Large TFT touch screen, 7.0
inch, logic software;
b. Bi
Bi--chromatic or reagent blank
measurement for all kinds of
tests;
c. Flexible calibration management;
d. Storage for 3000 sample results.
RT-1904c
RTa. Smaller character displaying,
controlled by rolling ball;
b. No bibi-chromatic or reagent blank
measurement for Kinetics and
Fixed--time tests;
Fixed
c. Only 3 calibration methods,
impossible to change calibration
parameters;
d. Storage for 600 sample results.
BA-88A
BAa. Large TFT screen, 7.0 inch;
b. Easy to operate (by touch
screen);
c. Room temperature, 25
25,
30
30
or 37
37 for testing;
d. Bi
Bi--chromatic measurement
for all kinds of tests;
e. External peristaltic pump,
easy to maintain;
f. Good heat abstractor, safe
for the operators.
BA-88A
BAa. Large TFT screen, 7.0 inch,
logic software;
b. Easy to operate (by touch
screen);
c. Two measuring modes: flowcell
or cuvettes;
d. 200 tests programmable;
e. Wavelength range: 340340-670nm;
f. Room temperature, 25
25, 30
30
or 37
37 for testing.
MC-15
MCa. Two
Two--line unicolour display;
b. Operated by membrane
buttons;
c. Measuring mode: cuvettes
(15 positions multicuvette
rack);
d. 60 tests programmable;
e. Wavelength range: 320320630nm;
f. Only 37
37 for testing.
Main Contents
Features
Working principles
Improvements from BA-88
Competitors
Operation
Price
FAQ
BA-88A operation
1. Choose test in
software
3. Add sample into
test tube
BA-88A operation
4. Shake to completely
mix reagent and sample
5. Aspirate the reaction
mixture into analyzer to start
measurement
Main Contents
Features
Working principles
Improvements from BA88
Competitors
Operation
Price
FAQ
Main Contents
Features
Working principles
Improvements from BA88
Competitors
Operation
Price
FAQ
Test
Method
Concentration
range
CV
ALT
Kinetic
(50~70)U/L
5%
UREA
Fixed-time
(8.00~10.00)mmol/L
3.5%
TP
End point
(50.0~65.0)g/L
2.5%